Triton ® 3D150 Diaphragm Pump
Used to pump waterborne and solvent-based paints and catalysts. For professional use only.
3:1 Ratio Air-operated Double Diaphragm Pump, with BSPP Fittings
3:1 Ratio Air-operated Double Diaphragm Pump, with NPT Fittings
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
300 psi (2.1 MPa, 21 bar) Maximum Fluid Working Pressure



The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury.


General Information
Tightening Threaded Fasteners Before First Use
See the Repair section for torque specifications.
Installation

Hexagonal screw (2 required)

Hexagonal screw (2 required)

FIG. 1. Mounting the Pump

a. The fluid pressure can be controlled with either an air regulator (F) to control the air into the pump, or with a fluid regulator (H) to control the fluid out of the pump.
b. Install a bleed-type master air valve (B) close to the pump. This valve is required in your system to relieve air trapped between it and the pump when the valve is closed. Trapped air can cause the pump to cycle unexpectedly which could result in serious injury including splashing in the eyes or on the skin, or injury from moving parts. Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator.
c. Install a second air valve (E) upstream from all air line accessories to isolate them during clean- ing and repair.
A fluid drain (J) valve is required in your system to relieve pressure in the hose if it is plugged. The drain valve reduces the risk of serious injury, including splashing in the eyes or on the skin, or contamination from hazardous fluids when relieving pressure. Install the valve close to the pump fluid outlet. To use the valve as a circulation valve, connect a tube (K) between the valve and pail.
d. Install an air line filter (D) to remove contami- nates such as dirt, moisture, and oil from the compressed air supply.
Some systems may require installation of a pressure relief valve at the pump outlet to prevent overpressur- ization and rupture of the pump or hose.
Thermal expansion of fluid in the outlet line can cause overpressurization. This can occur when using long fluid lines exposed to sunlight or ambient heat, or when pumping from a cool to a warm area (for exam- ple, from an underground tank).
Overpressurization can also occur if the pump is being used to feed fluid to a piston pump and the intake valve of the piston pump does not close, caus- ing fluid to back up in the outlet line.
Installation

Key: A TRITON 3D150 Pump B Bleed-type master air valve (required for pump) C Air supply line D Air line filter E Air line shutoff valve F Pump air regulator G Gun air regulator (used in spray system only) H Fluid pressure regulator (used in spray system only) J Drain/circulation valve K Drain tube L Suction tube M Pump fluid inlet N Pump fluid outlet P Fluid hose (shown connected to gun in spray system) R Gun air hose (used in spray system only) S Spray gun (used in spray system only) T Pump air inlet U Agitator (used in spray system only) W Ground wire
R B
G
T
J
H
E
F
D
P
W
M
A L
K
N
TI2373A
T
K
J
W
U
M
A
N
TI2127A
H
FIG. 2. Typical Installation
Installation


Before operating the pump, ground the system as explained below. Read the warnings on page 4.

Ground all of this equipment:
FIG. 3. Grounding the Pump
Installation

Pressure Relief Procedure
Read the warnings on page 3, and follow the Pres- sure Relief procedure below whenever you:
If you are flushing, run the pump long enough to thor- oughly clean the pump and hoses. Close the air regula- tor. Remove the suction tube (L) from compatible flushing fluid and place it in the fluid to be pumped.
For a short term shutdown, relieve the pressure (see procedure on this page).
The pump was tested in oil. If oil could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible flushing fluid. Follow the steps under Start- ing and Adjusting the Pump.
For a long term shutdown, such as several hours or overnight:
Operation

Lubrication
Tightening Threaded Connections
Lubrication of the pump is not required. Oil is exhausted through the muffler, which could contami- nate the fluid supply or other equipment. Excessive lubrication can also cause the pump to malfunction.
Flush the pump often enough to prevent the fluid you are pumping from curing, drying, or freezing in the pump and damaging it. Follow the Pressure Relief Proce- dure on page 10 before storing it for any length of time. Use a compatible flushing fluid.
Maintenance

Troubleshooting

Fault Indications
During operation, check for indications of worn or dam- aged parts, such as:
Always replace worn or damaged parts immediately to prevent additional damage.

a. Press on the cylinder-side diaphragm so that it protrudes into the cylinder. This will fully extend the diaphragm on the housing side.
Wear gloves when removing or assembling the dia- phragms to reduce the risk of cuts.
b. Install new ball check seals (29*).
Diaphragm Repair Kit 246011 is available. Parts included in the kit are marked, for example (9*). For the best results, replace both diaphragms.
c. Make sure the helicoil (56) is in place in each bolt hole. See Helicoil Installation, page 15.
d. Replace the fluid cover and install the 6 bolts. Torque the bolts to 16 N•m (12 ft-lb). Use blue Loctite or equivalent as needed. See General Repair Notes, page 13.
Always replace the ball check seals (29) whenever the fluid covers are removed. These seals are included in each of the repair kits.
a. Remove the 6 bolts (39) and fluid cover (37) from the housing side of the pump.
a. Remove the 6 bolts and the fluid cover from the housing side.
b. Press on the exposed diaphragm (9) to fully extend the cylinder-side diaphragm.
b. Remove the ball check seals.
c. The exposed diaphragm should be in the fully extended position (protruding out from the cylin- der). If it is not, reassemble the cylinder-side seals and cover and repeat step 3.
c. Replace the housing-side cover and tighten the 6 bolts.
d. Grip the housing-side diaphragm firmly and unscrew it from the rod by hand.
e. Install a new diaphragm (9*) firmly, by hand.
a. Remove the 6 bolts (38) and fluid cover (37) from the cylinder side.
f. Install new ball check seals (29*).
b. Remove the ball check seals (29).
g. Make sure the helicoil (56) is in place in each bolt hole. See Helicoil Installation, page 15.
c. The exposed diaphragm should be in the fully extended position (protruding out from the cylin- der). If it is not, reassemble the cylinder-side seals and cover and repeat step 1.
h. Replace the fluid cover and install the 6 bolts (39*). Torque the bolts to 16 N•m (12 ft-lb). Use blue thread locker as needed. See General Repair Notes, page 13.
d. Grip the cylinder-side diaphragm firmly and unscrew it from the rod by hand.
Spare diaphragms should be stored in a cool, dry place and be used within 8 months to prevent diaphragm fail- ure due to material aging.
e. Install a new diaphragm (9*) firmly, by hand.

To replace broken or removed helicoils (56), order Heli- coil Repair Kit 24U929. Also order Helicoil Installation Tool, Graco PN 24U930.
Torque to 16 N•m (12 ft-lb). Use blue Loctite or equivalent as needed. See General Repair Notes, page 13.

FIG. 4 Replace the Diaphragms
Housing Side 9*

Air Valve Repair Kit 245066 is available. Parts included in the kit are marked, for example (33†). For the best results, use all parts in the kit.

ti15227a

Lubricate.
Torque to 3.1 N•m (28 in-lb)

FIG. 5. Repair the Air Valve

Fluid Inlet and Outlet Adapters
If the fluid inlet adapter (1a) or outlet adapter (1c) have been removed, apply sealant primer and high strength anaerobic sealant to the adapter threads before install- ing. Be sure to install new o-rings (1b, 1d). Torque the adapters to 12.5-14.7 ft-lb (17-20 N•m).
Parts marked with a (O) are included in Bearing repair kit 15J647.

Lubricate.
Torque to 12 ft-lb (16 N•m). Use medium-strength (blue) thread locker or equivlaent as needed. See General Repair Notes, page 13.

Apply sealant primer and high-strength anaerobic sealant. Torque to 12.5-14.7 ft-lb (17-20 N•m).
FIG. 6. Repair the Shaft

Ball Check Valve Repair Kit 245067 is available. Parts included in the kit are marked with a (‡). For the best results, use all parts in the kit.

Torque to 12 ft-lb (16 N•m). Use medium-strength (blue) thread locker or equivlaent as needed. See General Repair Notes, page 13.

Align.
FIG. 7. Replace the Ball Check Valves


Parts

Ref. No. Part No. Description Qty
Ref. No. Part No. Description Qty
1 # HOUSING, diaphragm; includes items 1a-1d
35 15J372 COVER, exhaust 1 36 15J374 COVER, sheet metal, air valve 1 37 15A282 COVER, fluid 2 38 117240 BOLT, cap, socket head; M8x70 Torque to 16 N•m (12 ft-lb)
1a 15A306 ADAPTER, fluid inlet, for 253704 1 198852 ADAPTER, fluid inlet, for 253705 1 1b 198857 O-RING 1 1c 15A290 ADAPTER, fluid outlet, for 253704 1 198855 ADAPTER, fluid outlet, for 253705 1 1d 117036 O-RING 1 2 NO O-RING 3 3 O BEARING 3 4 117158 O-RING 1 5 197645 CARRIAGE, valve 1 6 15A289 CLAMP, sleeve 1 7 N SHAFT, pump, diaphragm 1 8 N O-RING 1 9 * DIAPHRAGM 2 10 197649 CARRIAGE 1 11 †N O-RING 2 12 197651 PLUG 2 13 †N O-RING 2 14 197653 CLIP, id 2 15 † CUP, air valve 1 16 † PLATE, air valve 1 17 †N O-RING 2 18 †N O-RING 1 19 †N GASKET, flat 1 20 197659 COVER, valve 1 21 116474 SCREW, cap, socket head; M4x20 Torque to 3.1 N•m (2.3 ft-lb)
39 115264 BOLT, cap, socket head; M8x18 Torque to 16 N•m (12 ft-lb)
40 15A286 ADAPTER, pump diaphragm, for 253704 1
198832 ADAPTER, pump diaphragm, for 253705 1
41 116343 CLAMP, grounding 1 42 O CLIP, ID, C-spring 3 43 O O-RING 3 44 116595 SCREW, M4 button head 2 45 111307 WASHER (used with #41, 116343) 1 46L 188621 LABEL, warning (not shown) 1 54 258001 HOUSING, cylinder 1 55 † O-RING 2 56 I Helicoil 12
# Included in Diaphragm Housing Repair Kit. Order Kit 261665 for 253704 pumps and 261666 for 253705 pumps.
N Included in Shaft Repair Kit 233841.
O Included in Bearing Repair Kit. Order Kit 15J647.
* Included in Diaphragm Repair Kit 246011.
† Included in Air Valve Repair Kit 245066.
‡ Included in Ball Check Valve Repair Kit 245067.
Available in 10-pack kit 15D564.
22 117160 VALVE, safety 1 23 197661 DAMPENER, noise 1 24 197662 PLATE, screw 1 25 116475 SCREW, cap, socket head; M4x12 2 26 ‡ BALL, matrix 4 27 ‡ SEAL, profile 2 28 ‡ SEAT, valve, outlet 2 29 *†‡N SEAL, profile 4 30 ‡ O-RING 2 31 ‡ SEAT, valve, inlet 2 32 ‡ GUIDE, ball 4 33 197670 DAMPENER, felt, side 1 34 197671 DAMPENER, felt, air inlet side 1
I Available in Helicoil Repair Kit 24U929 (quantity 16). Also order Helicoil Insert Tool 24U930.
L Replacement Warning labels, signs, tags, and cards are available at no cost.
Parts

Maximum fluid working pressure 300 psi (2.1 MPa, 21 bar)
Maximum air input pressure 100 psi (0.7 MPa, 7 bar)
Ratio 3:1
Maximum permissible stroke frequency in cycles/min 20
Volume per cycle (double stroke) 5 oz/cycle (150 cc/cycle)
Operating temperature range 50-176°F (10-80°C)
Dry suction lift 5 ft (1.5 m)
Wet suction lift 21 ft (6.5 m)
Air inlet size 1/4 npt (253705); 3/8 BSPP (253704)
Fluid inlet size 3/4 npt (253705); M26x1.5 (253704)
Fluid outlet size 3/8 npt (253705); 3/8 BSPP (253704)
Weight (approximate) 28 lb (12.7 kg)
Wetted parts stainless steel, acetal, fluorocarbon, PTFE, nylon
Sound Pressure Levels in dB(A) at 50 cpm (measured at 1 meter from unit)
Inlet Air Pressure Sound Pressure
29 psi (0.2 MPa, 2.0 bar) 72
58 psi (0.4 MPa, 4.0 bar) 76
87 psi (0.6 MPa, 6.0 bar) 78
100 psi (0.7 MPa, 7.0 bar)
Technical Data · Category Data

Triton performance test, 40, 70, 100 psi (.27, .48, .69 MPa; 2.7, 4.8, 6.9 bar)

100 psi (.69 MPa, 6.9 bar)
Outlet Pressure in PSI
Air Flow in SCFM
70 psi (.48 MPa, 4.8 bar)
40 psi (.27 MPa, 2.7 bar)
Outlet Flow in gallons per minute



Air Inlet 253705 1/4 npt 253704 3/8 BSPP
Dimensions

Dimensions

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com For patent information, see www.graco.com/patents
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 311688
Copyright 2006, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Rev. L - February 2014
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump cycles at stall or fails to hold pressure at stall. | Worn check valve balls (26), seats (31), or ball guides (32). | Replace. See page 20. | p.12 |
| Pump will not cycle, or cycles once and stops. | Stuck or dirty air valve. | Disassemble and clean air valve. See page 16. Use filtered air. | p.12 |
| Pump will not cycle, or cycles once and stops. | Check valve ball (26) severely worn and wedged in seat (31). | Replace ball and seat. See page 20. | p.12 |
| Pump will not cycle, or cycles once and stops. | Check valve ball (26) wedged in seat (31) due to overpressurization. | Replace. See page 20. Do not exceed the maximum fluid working pressure, see page 24. | p.12 |
| Pump will not cycle, or cycles once and stops. | Clogged fluid dispensing valve. | Relieve pressure and clear valve. | p.12 |
| Pump will not cycle, or cycles once and stops. | Pinched hose line. | Check lines. | p.12 |
| Pump operates erratically. | Clogged suction line. | Inspect; clear. | p.12 |
| Pump operates erratically. | Sticky or leaking check valves. | Clean or replace balls (26) and seats (31). See page 20. | p.12 |
| Pump operates erratically. | Ruptured diaphragm (9). | Replace. See page 13. | p.12 |
| Pump operates erratically. | Restricted exhaust. | Remove restriction. | p.12 |
| Air bubbles in fluid. | Loose suction line. | Tighten. | p.12 |
| Air bubbles in fluid. | Ruptured diaphragm (9). | Replace. See page 13. | p.12 |
| Pump running irregularly. Stroke fre- quency dropping, coming to stand- still. | Worn parts. | Replace worn parts. Check com- pressed air supply. | p.12 |
| Pump running irregularly. Stroke fre- quency dropping, coming to stand- still. | Icing caused by: compressed air too moist, stroke frequency too high, local temperature too low. | Remove ice by changing operating conditions. | p.12 |
| Air escapes continually. | Damaged air valve cup (15) or seat. | Replace damaged parts. See page 16. | p.12 |
| Air escapes continually. | Foreign matter inside pump. | Check air filter. | p.12 |
| Pump does not start, or pressure fluctuates. | Worn check valve seats. | Replace. See page 20. | p.12 |
| Pump does not start, or pressure fluctuates. | Inlet strainer blocked, maximum suc- tion exceeded, hose or seal defec- tive. | Clean strainer. Replace defective parts. | p.12 |
| Pump does not start, or pressure fluctuates. | Contaminated fluid. Pump installed or operated incorrectly. | Check fluid supply. Follow installation and operation instructions in this manual. | p.12 |
Owners and our team usually reply within a day — and your question helps the next person too.