T2 2:1 Ratio Transfer Pump
For use with polyurethane foam, polyurea, and similar non-flammable materials. For professional use only.
Not for use in explosive atmospheres.
Model 295616 (55-gallon drum) 180 psi (1.2 MPa, 12 bar) Maximum Air Working Pressure 405 psi (2.7 MPa, 27 bar) Maximum Fluid Working Pressure

Operation 11
Pressure Relief Procedure 11 Flushing 11 Daily Startup 11 Daily Shutdown 11 Air Motor Repair 12 Pump Lower Repair 14 Reassembly 17 Troubleshooting 17 Parts - Model 295616 18 Accessories 20 Technical Data 22
Isocyanate Hazard 4 Foam Self-Ignition 4 Keep Components A and B Separate 4 Changing Materials 4 Typical Installation 5
Typical Installation, without Circulation 5 Typical Installation, with Circulation 6 Typical Installation for Lubrication Applications . 7 Installation 8
System Accessories 8 Air Line Accessories 8 Fluid Line Accessories 8 Setup 9
Dimensions 22 Performance Chart 23 Graco Standard Warranty 24 Graco Information 24
Grounding the System 10
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.


Moisture Sensitivity of Isocyanates
Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts.
Read material manufacturer’s warnings and material MSDS to know the specific hazards of isocyanates. Use equipment in a well-ventilated area. Wear respirator, gloves, and protective clothing when using isocyanates.
The amount of film formation and rate of crystallization varies depending on the blend of ISO, the humidity, and the temperature.
To prevent exposing ISO to moisture:
Some materials may become self-igniting if applied too thick. Read material manufacturer’s warnings and material MSDS.

Typical Installation, without Circulation
Key for FIG. 1
A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Proportioner and Gun Air Supply Hose G Feed Pump Air Supply Lines (3/8 in. (76 mm) ID min.
H Waste Containers J Fluid Supply Lines (217382) K Feed Pumps L Agitator M Desiccant Dryer N Bleed Lines/Over Pressure Relief P Gun Fluid Manifold

M
K
A
N
F
J
D
E
P
H
C*
B
* Shown exposed for clarity. Wrap with tape during operation.
Typical Installation · ti11572a

Key for FIG. 2
A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Fusion Spray Gun F Proportioner and Gun Air Supply Hose
G Feed Pump Air Supply Lines (3/8 in. (76 mm) ID min) J Fluid Supply Lines K Feed Pumps L Agitator M Desiccant Dryer N Recirculation/Over Pressure Relief Return Hoses P Gun Fluid Manifold

M
M
K
A
F N
J
D
E
N
P
C*
B
* Shown exposed for clarity. Wrap with tape during operation.
Typical Installation · ti11571a

Key for FIG. 3
A Pump Air Regulator B Air Line Lubricator C Air Line Filter D Bleed-Type Master Air Valve (required, for pump) E Fluid Drain Valve (required) F Bung Adapter
G Grounded Air Hose H Grounded Fluid Hose J Pump Fluid Inlet K 1/4 npt(f) Pump Air Inlet L 3/4 npt(f) Pump Fluid Outlet
D
K

G
H
E
J
J
Typical Installation

Fluid Line Accessories
A fluid drain valve (E) is required in your system to relieve fluid pressure in the hose and gun (see the WARNING on left). Install the drain valve so that it points down and the handle points up when the valve is opened.
A bleed-type master air valve (D) and a fluid drain valve (E) are required in your system, to help reduce the risk of serious injury, including splashing fluid in the eyes or on the skin, and injury from moving parts when you are adjusting or repairing the pump.
The bleed-type master air valve (D) relieves air trapped between this valve and the pump after the pump is shut off. Trapped air can cause the pump to cycle unexpectedly and result in serious injury, including amputation. Install the valve close to the pump.
The fluid drain valve (E) helps relieve pressure in the displacement pump, hose, and dispensing valve when shutting off the pump. Actuating the dispensing valve to relieve pressure may not be sufficient, espe- cially if there is a clog in the hose or the dispensing valve.
To ensure maximum pump performance, be sure that all accessories used are properly sized to meet your sys- tem’s requirements. See Accessories, page 20.
Install the following accessories in the order shown in the Typical Installation for Lubrication Applications, using adapters as necessary:
An air line lubricator (B) provides automatic air motor lubrication.
A bleed-type master air valve (D) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING on left). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regu- lator.
An air line filter (C) to remove harmful dirt and moisture from the compressed air supply.
A second bleed-type air valve (D) isolates the air line accessories for servicing. Locate upstream from all other air line accessories.
Installation


Setup



To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment.
Setup

Pressure Relief Procedure
Trapped air can cause the pump to cycle unexpect- edly, which could result in serious injury from splashing or moving parts.
Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed and could cause personal injury and/or dam- age to the pump. If the pump accelerates quickly or starts running too fast, stop it immediately and check the fluid supply. If the supply container is empty or air has been pumped into the lines, refill the container and prime the pump and the lines with fluid, or flush and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system.
Trapped air can cause the pump to cycle unexpect- edly, which could result in serious injury from splashing or moving parts.
Do not attempt to operate pump unless it is securely mounted in a drum.
Operation





Air Motor Repair




Air Motor Repair




Pump Lower Repair · *38





Pump Lower Repair · *35 · ti9904b




Pump Lower Repair

To reassemble the pump lower and air motor, reverse the steps on the preceding pages. Follow the torque requirements listed in the Parts - Model 295616 draw- ing on page 18.
The pump fails to operate Dirty or worn air motor. Clean, service
Inadequate air supply or restricted lines.
Clean lines or increase the air supply (see Technical Data).
Closed or clogged air valves. Open or clear the valves.
Clogged fluid hose or valve. Clear the hose or valves
Worn or damaged valves or seals. Service the valves or seals.
The pump operates, but the output is low on both strokes.
Clogged fluid hose or valve. Clear the hose or valves.
Exhausted fluid supply. Refill the fluid supply and reprime the pump.
Worn or damaged valves or seals. Service the valves or seals.
The pump operates, but the output is low on the downstroke.
Held open or worn intake valve. Clear or service the valve.
Worn or damaged valves or seals. Service the valves or seals.
The pump operates, but the output is low on the upstroke.
Held open or worn piston valve. Clear or service the valve.
Worn or damaged valves or seals. Service the valves or seals.
Erratic or accelerated operation. Exhausted fluid supply. Refill the fluid supply and reprime the pump.
Broken air motor compression spring. Replace the spring.
Pump slowly moves after fluid shutoff in downstroke.
Clogged or dirty intake valve check ball.
Clean ball and seat.
Worn or damaged valves or seats. Install repair kit.
Pump slowly moves after fluid shutoff in upstroke.
Clogged or dirty lower piston ball or seat.
Clean ball and seat.
Worn or damaged valves or seats. Install repair kit.
Reassembly · Problem Cause Solution

Parts - Model 295616

Lubricate all o-rings and seals before and after assembly

Parts - Model 295616
Ref Part Description Qty 1‡ 16V524 CAP, air cylinder 1 2‡ 157630 SPRING, tapered 1 3‡* 120212 PACKING, square 2 4 24J528 CYLINDER, air motor 1 5✿ 262035 VALVE, air 1 5a* 15J539 GASKET, upper 1 5b* 121889 O-RING 3 5c 15J544 SPACER 3 5d 121610 SCREW 3 5e 16U730 CAP, air, valve 1 5f 15V554 HEAD, air valve 1 5g 15J546 DISK, air valve 1 5h* 160258 O-RING 1 5j* 722834 O-RING 1 17✿ CAP, air piston 1 19✿ 15J548 PIN, dowel 1 20❄ SHAFT, transfer 1 21 24J535 PISTON, air 1 22 15J551 SPRING, compression 1 23 24J529 BASE, air motor 1 24* 159846 O-RING (green) 1 25 15J553 ROD, tie 3 26 24J530 FLANGE, mounting 1 27 15J555 NUT, hex 1 28* 15J556 GLAND, packing, (male) 1 29* 15J557 V-PACKING, PTFE 2 30* 15J558 GLAND, packing, (female) 1 31* 15J559 WIPER, ROD 1 32* 15C638 O-RING, PTFE, encapsulated 1 33* 15J560 GASKET, PTFE 1 34 24J536 BODY, pump, 2:1 1 35✓ 15J562 PACKING, piston cup 1 36 15J563 COLLAR, retaining 1 37 101194 SCREW, set, socket head, 10-32 x .25 in. (6 mm) 1
Ref Part Description Qty
56✓ 120295 PIN, clevis, 3/16 in. x 1-1/4 in. 1 60 120348 SCREW, cap, socket head 1/4-20 x 1 in. (25 mm) 3
69† 15H197 TOOL, pin 2 70† 15K008 LABEL, material identification. 1 71✓ 107167 BALL, intake, sst, 1 in. (25 mm) 1 72 116343 SCREW, ground 1 73✓ 113944 O-RING 1 74❄ SHAFT, transfer, lower 1 75 24V858 GUARD 1 76‡ 111819 O-RING 1 77‡ 16V523 PIN, spring stop 1
* Parts included in Upper Seal Repair Kit 262034 (not sold separately).
✓Parts included in Lower Seal Repair Kit 247883.
❄Parts included in repair kit 256560
✿Parts included in repair kit 262042
† Indicates parts not shown, 48, 49, 52, 69, 70 (shipped loose)
38✓★106258 O-RING 2 39 24J534 CYLINDER, fluid 1 40✓ 15J565 PACKING, u-cup, PTFE 1 41✓ 15J566 RING, wear 1 42✓ 103462 BALL, outlet, sst, 3/4 in. (19 mm) 1 43 24J531 VALVE, piston 1 44 24J532 TUBE, suction 1 45 24J533 VALVE 1 46 120734 RING, retaining, internal 1 47 120735 RING, snap, e series 1 48† 206264 VALVE, needle 1 49† 169969 FITTING, air line 1 50*✿108832 O-RING 1 51 253146 ADAPTER, bung (includes 51a-51g)
★ O-rings included in Tube Extension Kit 24N451.
‡ Parts included in air cap 24T043
51a✓120998 O-RING, fluoroelastomer 1 51b 24J526 ADAPTER 1 51c 234188 CLAMP, hopper 1 51h✓120207 O-RING; inner (brown) 1 52† 114558 COUPLER, air line 1 53 15J570 HOUSING, piston 1 54❄ PISTON, upper 1 55✓❄120294 PIN, clevis, 3/16 in. x 3/4 in. 2

Air Line Lubricator
250 psi (1.7 MPa, 17.5 bar) Maximum Working Pressure
. 103538 CLAMP, ground 1
. 214848 LUBRICATOR, air line; 8 oz (0.24 liter) bowl capacity; 1/2 npt(f) inlet and outlet
300 psi (2.1 MPa, 21 bar) Maximum Working Pressure
180 psi (1.3 MPa, 13 bar) Maximum Working Pressure
. 107142 VALVE, ball, vented; 1/2 npt(m) inlet x 1/2 npt(f) outlet
. 202660 FILTER, air; includes gauge and two 1/4 npt(m) outlet valves, 50 micron filter ele- ment with 100 mesh inlet strainer; 1/2 npt(f) inlet; flow rate is over 50 scfm (1.4 m3/min).
250 psi (1.7 MPa, 17.5 bar) Maximum Working Pressure
. 106149 FILTER, air line; 1/2 npt(f) inlet and outlet 1

Fluid Drain Valve
300 psi (2.1 MPa, 21 bar) Maximum Working Pressure
500 psi (3.5 MPa, 35 bar) Maximum Working Pressure
. 202156 REGULATOR, air; 0-200 psi (0-14 bar) regulated pressure range; 3/8 npt(f) inlet and outlet
. 208630 VALVE, ball; 1/2 npt(m) x 3/8 npt(f); for non-corrosive fluids; carbon steel and PTFE
237534 VALVE, ball; 3/8 npt(m) x 3/8 npt(f); for corrosive fluids; SST and PTFE

T2 2:1 Ratio Transfer Pump
US Metric Pressure Ratio 2.25:1 Max fluid working pressure 405 psi 2.8 MPa, 28 bar Maximum Air inlet pressure 180 psi 1.2 MPa, 12 bar Max Output Flow (continuous) 5.0 GPM 20 lpm
Max Output Flow (intermittent 7.5 GPM 28 lpm Pump cycles per 1 gallon (3.8 liters) 15.9 Maximum recommended pump speed for con- tinuous operation
100 cycles per min (150 cycles per min intermittent)
Gallons (liters) per pump cycle 0.063 gal. 0.24 l Air consumption See performance chart Maximum Ambient temperature 120° F 50° C Maximum Fluid Temperature 190° F 88° C Wetted parts Stainless Steel, PTFE Air Inlet Port 1/4 npt(f) Fluid Outlet Port 3/4 npt(f) Weight 21.0 lb 9.5 kg Sound Pressure 88.7 dB(A) at 80 psi (.55 MPa, 5.5 bar) Sound Power, per ISO 9614-2 96.8 dB(A) at 80 psi (.55 MPa, 5.5 bar)

Technical Data

Calculate Pump Air Consumption (gray curves)
To calculate fluid outlet pressure (MPa/bar/psi) at a spe- cific fluid flow (lpm/gpm) and operating air pressure (MPa/bar/psi), use the following instructions and pump data chart.
To calculate pump air consumption (m3/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (MPa/bar/psi), use the following instructions and pump data chart.
40.00 (1.1)
(3.5, 34.5)
Air Consumption in SCFM (m3/min)
A 180 psi (1.2 MPa, 12.4 bar) B 100 psi (0.7 MPa, 7 bar) C 70 psi (0.5 MPa, 4.8 bar) D 40 psi (0.3 MPa, 2.8 bar)
Outlet Pressure in PSI (MPa, bar)
(1.0)
(2.8, 28)
(0.8)
(0.7)
(2.1, 21)
(0.6)
A
(1.4,14)
(0.4)
(0.3)
C D
(0.7, 7)
(0.1)
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0.0
(17.1) (15.2) (13.3) (9.5) (5.7) (1.9) (11.4) (7.6) (3.8)
Fluid Flow in gpm (lpm)
Technical Data

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 311882
Copyright 2007, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revision T, October 2014
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The pump fails to operate | Dirty or worn air motor. | Clean, service | p.17 |
| The pump fails to operate | Inadequate air supply or restricted lines. | Clean lines or increase the air supply (see Technical Data). | p.17 |
| The pump fails to operate | Closed or clogged air valves. | Open or clear the valves. | p.17 |
| The pump fails to operate | Clogged fluid hose or valve. | Clear the hose or valves | p.17 |
| The pump fails to operate | Worn or damaged valves or seals. | Service the valves or seals. | p.17 |
| The pump operates, but the output is low on both strokes. | Clogged fluid hose or valve. | Clear the hose or valves. | p.17 |
| The pump operates, but the output is low on both strokes. | Exhausted fluid supply. | Refill the fluid supply and reprime the pump. | p.17 |
| The pump operates, but the output is low on both strokes. | Worn or damaged valves or seals. | Service the valves or seals. | p.17 |
| The pump operates, but the output is low on the downstroke. | Held open or worn intake valve. | Clear or service the valve. | p.17 |
| The pump operates, but the output is low on the upstroke. | Held open or worn piston valve. | Clear or service the valve. | p.17 |
| Erratic or accelerated operation. | Exhausted fluid supply. | Refill the fluid supply and reprime the pump. | p.17 |
| Erratic or accelerated operation. | Broken air motor compression spring. | Replace the spring. | p.17 |
| Pump slowly moves after fluid shutoff in downstroke. | Clogged or dirty intake valve check ball. | Clean ball and seat. | p.17 |
| Pump slowly moves after fluid shutoff in downstroke. | Worn or damaged valves or seats. | Install repair kit. | p.17 |
| Pump slowly moves after fluid shutoff in upstroke. | Clogged or dirty lower piston ball or seat. | Clean ball and seat. | p.17 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.