GBL 7500 Box Lubricator Pump GBL Shaft Rotation/Low Level Alarm Pump
GBL 7500 Box Lubricator Pump: Fully enclosed, self-lubricating, precision, metering pump capable of pumping small flows of either mineral or synthetic oil to machinery injection points. For professional use only.
GBL Shaft Rotation/Low Level Alarm Pump: Fully enclosed, self-lubricating, precision, alarm pump capable of sensing shaft rotation and oil low level. For professional use only.
3/16” models: 7500 psi (51.7 MPa, 517 bar) Maximum Working Pressure 1/4” models: 6000 psi (41.4 MPa, 414 bar) Maximum Working Pressure 3/8” models: 3500 psi (24.1 MPa, 241 bar) Maximum Working Pressure Alarm Pump: 200 psi (1.4 MPa, 14 bar) Maximum Working Pressure


The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treat- ment. • Do not point dispensing device at anyone or at any part of the body.
+


Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop pumping and before cleaning, checking or servicing the equipment.
The equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current.
Ensure the reservoir is properly grounded as the pump is grounded through the mounting screws.
a. Check length of suction tube. If it is too long to fit in the reservoir, use a pliers to break off the lower section of the tube (a) (FIG. 2).
NOTE:


Any pressure applied to the pump inlet has the potential to cause unrestricted flow from the pump outlet even in a pump that is at rest or adjusted for zero stroke. To pre- vent this from happening, install a check valve of a com- parable pressure rating at the pump outlet.
b. For all installations (whether the tube needs to be trimmed or can be used without trimming), press strainer onto end of the suction tube until it “bottoms” (FIG. 3).

- Gravity Fed Pump With Sight Glass: 10 psi
(0.07 MPa, 0.7 bar)
a · bar) · bar)

Gravity Fed Models (F IG . 5)




Alarm Pump Models (F IG . 7)



Pump volume is controlled by an external adjusting screw (8) (FIG. 9). Turning the adjusting screw changes the length of the piston stroke which changes the pump discharge volume.


If inst

The number of drops observed falling in the sight well equals the amount of oil discharged by the pump. The pump volume can be adjusted using the adjusting screw (8) (FIG. 9) to change the piston stroke. (See Adjusting the Pump.)

Calculating Pints per Day
Calculating Minimum or Maximum Pump Output Capacity in Pints per Day
% & '(
& %
* Minimum and Maximum drops per stroke listed in Specifications, page 10.
The number of drops seen falling in the sight well equals the amount of oil discharged by the pump. See Specifi- cations, page 10 for additional information on converting drops to volumetric output.
Example:
The following example calculates the maximum and minimum flow for a 1/4 inch pump model with an electric motor and 300:1 gear ratio.
For Pressure Fed models only: Measure the output volume at the lube point.
To calculate the Maximum Flow:
Max 12 drops per stroke 1440 min. X X
300:1 Gear Ratio
Max 6.88 Pints/day
14438(Number of Drops in a Pint) =
To calculate the Minimum Flow:
Replace the maximum 12 drops per stroke (used in the equation above) with the minimum 2 drops per stroke = 1.17 minimum pints per day.
! " · #$

Table 1 Drops per Stroke Table Section of Table Applies to Suction and Gravity Fed Models Only
† Refer to your manufacturer’s specific instruction manuals to ensure your box and lubrication system are rated for the selected pressure.
1 Based on 500 SUS oil at 70°F ambient. Heavier oil will produce fewer but larger drops.
2When approaching maximum outputs, some oils will stream rather than form drops in sight glass.
Fluid Measurement Conversion Data
Specifications

* Oil level in sight well will rise and fall during normal operation. If condition persists refer to Cause/Solution sections.
Troubleshooting

Should the oil level in the sight well (2) fall below the pump body surface:

To replace a cloudy or broken sight glass in suction or gravity fed pumps, order GBL7500 Sight Glass Replace- ment Kit 24T306. See instruction manual 332560 included with Kit 24T306 for repair and replacement instructions.
Custom Socket Tool 16Y532
Used with the GBL7500 Sight Glass Replacement Kit for removing, tightening and torquing the Sight Glass Body (5). See instruction manual 332560 included with Kit 24T306 for repair and replacement instructions.
The oil level in the sight well (2) will rise and fall slightly during pump operation. Should the oil level in the sight well rise above the drip tube (4):
Maintenance

Suction, Gravity Pressure Fed Box Lubricator Pump or Shaft Rotation Alarm Pump
Maximum Working Pressure US Metric
All 3/16” Piston Models 7500 psi 51.7 MPa, 517 bar
All 1/4” Piston Models 6000 psi 41.4 MPa, 414 bar
All 3/8” Piston Models 3500 psi 24.1 MPa, 241 bar
Alarm Pump* 200 1.4 PMa, 14 bar
Gravity Fed Models 1/8” - 27 NPTF
Pressure Fed Models 1/4” - 18 NPTF
Outlet Size (Suction, Gravity, Pressure Fed Models) 1/8” - 27 NPTF
Suction Models 2.6 lbs 1.18 kg
Gravity Models 2.7 lbs 1.22 kg
Pressure Models 2.7 lbs 1.22 kg
Alarm Pump 4.8 lbs 2.18 kg
Temperature Rating -20°F to 140F° -29°C to 60°C
Wetted Parts carbon steel, stainless steel, aluminum, PTFE, Fluoro- elastomer, pyrex
* Sensor output will open at 100-200 psi (0.68 MPa, 6.89 bar).
Inlet Size · Dimensions page 14 · Weight


Dimension Inches mm A 3.10 76.20 B 1.97 50.04 C 0.50 12.70
Min. 105.20 Max 124.50 G 1.50 38.10 H 0.50 12.70 J 0.50 12.70 K 0.39 9.90 L 0.92 23.37 M 0.28 7.11 N 5.40 137.20 P 3.85 97.79 R 10.13 257.18




A
D
N
Outlet · Inlet

1/4 NPT Sensor Output

P
D
N
Return to Reservoir · Inlet

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 3A2257
Copyright 2012, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revised December 2013
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump does not flow | Pump stroke is adjusted to zero. | Adjust pump stroke for desired out- put. See page 8. | p.11 |
| Pump does not flow | Pump outlet is plugged. | Clean/flush pump outlet. | p.11 |
| Pump does not flow | Outlet check valve damaged. | Replace pump. | p.11 |
| Pump does not flow | Pump inlet check ball and/or seat is damaged or worn. | p.11 | |
| Pump has low flow | Pump stroke is adjusted to minimal travel. | Adjust pump stroke for desired out- put. See page 8. | p.11 |
| Pump has low flow | Pump inlet check ball and/or seat is damaged or worn. | Replace pump. | p.11 |
| Pump has low flow | Outlet check valve damaged. | p.11 | |
| Pump has low discharge pressure | Piston and bore are worn. | Replace pump. | p.11 |
| Pump has low discharge pressure | Pump inlet check valve and/or seat are damaged or worn. | p.11 | |
| Fluid flow from pump outlet when pump is not running | Inlet pressure exceeds outlet check pressure. | Reduce inlet pressure to below out- let check pressure. | p.11 |
| Fluid flow from pump outlet when pump is not running | Pump outlet check ball and/or seat is damaged or worn. | Replace pump. | p.11 |
| Sight well fills with oil* | Possible debris in inlet check | Perform Maintenance, page 12. | p.11 |
| Sight well fills with oil* | Pump inlet check ball and/or seat is damaged or worn | Replace pump. | p.11 |
| Sight well fills with oil* | Piston and bore are worn | p.11 | |
| Sight well runs dry* | Restriction in Drip or Suction tube | Perform Maintenance, page 12. | p.11 |
| Sight well runs dry* | Air leak in sight well | Replace pump. | p.11 |
| Sight well remains constant and no lubricant drips from tube | Pump air bound | Follow Setup section appropriate for your pump model, pages 5-8. | p.11 |
| Sight well remains constant and no lubricant drips from tube | Pump regulation set too low | Increase pump regulation. | p.11 |
| Sight well remains constant and no lubricant drips from tube | Camshaft speed too slow | Increase camshaft speed (see Table 1, page 10. | p.11 |
| Cloudy or broken sight glass (Suc- tion or Gravity Fed Pumps only) | NA | Replace sight glass using GBL7500 Sight Glass Replacement Kit 24T306. See Maintenance, page 12. | p.11 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.