The following general warnings are for the setup, use, grounding, maintenance, and repair of this equipment. Addi- tional, more specific warnings may be found throughout the body of this manual where applicable. Symbols appear- ing in the body of the manual refer to these general warnings. When these symbols appear throughout the manual, refer back to these pages for a description of the specific hazard.


Grounding
Mounting
Proper grounding is an essential part of maintaining a safe system.

To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
Mount the pump securely so that it cannot move around during operation. Failure to do so could result in personal injury or equipment damage.
Ground the following equipment:
To ground the pump, remove the ground screw (Z) and insert through the eye of the ring terminal at end of the ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See FIG. 1. To order a ground wire and clamp, order Part No. 222011.

Installation


Do not hang the air accessories directly on the air inlet. The fittings are not strong enough to support the accessories and may cause one or more to break. Provide a bracket on which to mount the accessories.
See FIG. 2.
Install the air line accessories in the order shown in FIG. 2.
Three accessories are required in your system: an air shut-off valve/air bleed device, fluid drain valve, and ground wire. These accessories help reduce the risk of serious bodily injury, including skin injection, splashing in the eyes or on the skin, injury from moving parts if you are adjusting or repairing the pump, and explosion from static sparking.

Recommended air line configuration to reduce moisture in pump
KEY A Fluid dispense line B Pump ground wire (required) C Air regulator with gauge D Main air supply line E Air line filter F Air line lubricator G Pump runaway valve H Follower plate J Bleed-type master air valves (required) K Fluid drain valve 1/2 in.
Installation

Pressure Relief Procedure

The pump has a rated ratio of 50:1. However, it is capable of reaching stall pressures equal to 60 times the air input pressure. Calculate the fluid out- put pressure using the air regulator reading. Multi- ply the air pressure shown on the regulator gauge by 60. For example:
140 psi air x 60 = 8400 psi fluid output) (0.97 MPa air = 58.2 MPa fluid output 99.7 bar air x 60 = 582 bar fluid output
Regulate air to the pump so that no air line or fluid line component or accessory is overpressurized.

A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump accelerates quickly, or is running too fast, stop it immediately and check the material supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with material, or flush it and leave it filled with a compatible solvent. Be sure to eliminate all air from the material lines.
A pump runaway valve can be installed on the air line to automatically shut off the pump if it starts to run too fast.
When the pump is primed, and with sufficient air supplied, the pump starts when the dispensing valve is opened and shuts off when it is closed.
Operation

Relieve pressure before you check or service any system equipment.
Troubleshooting

When there is endplay at the pinned connection, you should be able to slightly move from side-to-side, the connecting rod (57) pinned to the displacement rod (8) and the piston (52) pinned to the priming rod (58).
If these connections seem too rigid:
Fig 1 - 1/2 Turn Too Deep
Does not permit end play

To avoid damaging the shovel tube, do not use slots in the tube to tighten or loosen tube.
Fig 2 - 1/2 Turn Too Shallow

Does not permit end play
Permits end play Fig 3 - Correct


Displacement Pump Service

Using nut (63), torque the pump cylinder (59) to the extension tube (64) at 45-55 ft-lb (61-75 N•m).

Lubricate.
Flat side must face retainer (106).
Assemble pin (53) flush or below surface.
Large bevel must face piston (52).
Lubricate inside diameter.
See endplay Note included in Step 10, Pump Disassembly instructions (page 8) for additional assembly instructions.
Displacement Pump Service

Air Motor and Throat Service
To avoid damaging the cylinder wall, lift the cylinder straight up off of the piston. Never tilt the cylinder while you are removing it.
To remove cracked exhaust valve poppets (16), stretch them out, and cut them with a sharp knife.
In step 7, do not damage the plated surface of the trip rod (11). A damaged trip rod could cause erratic air motor operation. Use the special padded pliers (248198) to grasp the rod.

Air Motor and Throat Service

Torque extension tube (64) to the base (5) at 45 to 55 ft-lb (61 to 75 N•m.

Air Motor and Throat Service

Cut off tops of poppets as indicated by dotted lines

Model No. 246909, Series C, Pail Length Model No. 246780, Series C, 120-pound Drum Length Model No. 246781, Series C, 400-pound drum length Model No. 253361, Series C, Pail Length without Handle
* Replacements for these parts are available in Repair Kit 246919 which may be purchased separately.
†Replacements for these parts are available in Repair Kit 246920 which may be purchased separately.
1 See endplay Note included in Step 10, Pump Disassembly instructions (page 8) for additional assembly instructions.

Parts

Pump
Ref. No Part No. Description
Ref. No Part No. Description
. 1* 248211 VALVE, poppet 2 2 15W205 PISTON, air motor 1 5 253999 BASE, air motor (includes 5a) 1 5a 116343 SCREW, grounding 1 6† 118355 SEAL, throat, polyurethane 1 7 162718 ADAPTER 1 8 15C527 ROD, displacement 1 9* 113347 O-RING, buna-N 1 10 118109 O-RING, buna-N 1 11 15C279 ROD, trip 1 12* 118107 GROMMET, rubber, air intake 2 13 15C249 ACTUATOR, valve 1 14 15C248 CLIP, spring 2 15 118718 SCREW, round head machine 2 16* 15C267 POPPET, valve, urethane 2 17 15C274 CYLINDER, air motor 1 18 246782 PLATE, identification; with muffler 1 19 100078 SCREW, hex head 12 20 246783 PLATE, warning; with muffler 1 21 101578 SCREW, hex head 6 22 15C245 YOKE, rod, trip 1 23 15C275 PIN, toggle 2 24* 118108 O-RING, nitrile rubber 1 25 15C277 ARM, toggle 2 26 15C276 ROCKER, toggle 2 27 118111 SPRING, helical compression 2 28 156698 O-RING, buna-N 1 29a 15F691 HANDLE NUT, cylinder cap (Model 246909)
. 52 15G098 PISTON 1 53† 119956 PIN, straight 2 54† 15G116 SEAL, piston 1 56† 112154 PIN, straight, slotted 1 57 15C758 ROD, extension (Model 246909 and 253361)
15C541 ROD, extension (Model 246780) 1 15C542 ROD, extension (Model 246781) 1 58 15F296 ROD, shovel 1 59 15C537 CYLINDER, pump 1 60† 192533 SEAL, gasket 2 61 119955 O-RING 1 62† 15G096 SEAL, shovel rod 1 63 15F169 CONNECTOR, tube 1 64 192682 TUBE, extension (Model 246909 and 253361)
193760 TUBE, extension (Model 246780 1 193758 TUBE, extension (Model 246781) 1 66 192660 SHOVEL 1 67 17A265 TUBE, shovel 1
†Replacements for these parts are available in
Repair Kit 246920 which may be purchased separately
29b 15C278 NUT, cylinder cap (Models 253361, 246780 and 246781)
30* 15C246 NUT, adjusting 4 31* 15C247 LOCKWIRE, transfer valve 2 33 15C266 GASKET, copper 1 38 15C530 NUT, packing 1
Replacement Danger and Warning labels, tags, and
cards are available at no cost.
* Replacements for these parts are available in Repair Kit 246919 which may be purchased separately
Two accessory tools are required for air motor and throat service: padded pliers 248198 and gauge 15E796 (included in repair kit 246919) to ensure gap is set correctly
Parts · Qty · Qty

Model 246909 pail length Model 253361 pail length without handle
Model 246781 400 lb drum size Model 246780 120 lb drum size

17.5 in. (445 mm) 26.7 in. (678 mm) 33.6 in. (853 mm)
Overall length: 30.2 in (768 mm) Overall length: 37.6 in (955 mm) Overall length: 44.5 in (1130 mm)
Pump Base Order gasket 15R881 for sealed tank/drum mounting.

4.250” (10.8 cm) bolt circle 0.281” (7.1 mm) diameter clearance holes
4.250” (10.8 cm) bolt circle 0.266” (6.7 mm) diameter clearance holes
Dimensional Drawings

Maximum fluid working pressure 8400 psi (58 MPa, 580 bar) Maximum air inlet pressure 140 psi (1.0 MPa, 10 bar) Ratio 50:1 Pump cycles per lb (.45 kg) 130 Maximum recommended pump speed 100 cycles/min Recommended pump speed for continuous operation 60 cycles/min Maximum delivery 56 lb/min (.25 kg/min) at 60 cycles/min Stroke length 2.0 in. (50.8 mm) Maximum pump operating temperature 130°F (54°C) Air inlet size 3/8 npt(f) Fluid outlet size 1/4 npt(f) Wetted parts . . . carbon steel; zinc plating; brass; polyurethane; ultra-high molecular weight polyethylene; Buna-N Sound pressure level (measured 1 meter from unit) 77.8 dB(A) @ 140 psi, 100 cpm Sound power level (tested in accordance with ISO 9614-2 85.6 dB(A) @ 140 psi, 100 cpm Approximate weight 15 lb (6.8 kg)
All brand names or marks are used for identification purposes and are trademarks of their respective owners.
Technical Data

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 309966
Copyright 2006, Graco Inc. is registered to ISO 9001
www.graco.com Revised April 2015
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate | Inadequate air supply pressure or restricted air lines | Increase air supply and/or clear restriction. | p.7 |
| Pump fails to operate | Closed or clogged pump valves | Open and/or clean. | p.7 |
| Pump fails to operate | Clogged fluid line, hose, valve, or other accessory | Relieve pressure. Clear obstruction. | p.7 |
| Pump fails to operate | Damaged air motor | Assess damage, and service air motor. | p.7 |
| Pump fails to operate | Exhausted fluid supply | Refill and reprime or flush. | p.7 |
| Continuous air exhaust | Worn or damaged air motor gasket or seal | Assess wear or damage, and service air motor. | p.7 |
| Erratic pump operation | Exhausted fluid supply | Refill and reprime or flush. | p.7 |
| Erratic pump operation | Worn pump seals | Replace. | p.7 |
| Erratic pump operation | Damaged shovel tube | Replace. | p.7 |
| Erratic pump operation | Damaged check seat | Replace pump piston or shovel rod (or other damaged part). | p.7 |
| Errataic or accelerated pump speed | Exhausted fluid supply | Refill and reprime of flush. | p.7 |
| Errataic or accelerated pump speed | Fluid too heavy for pump priming | Use inductor or follow plate. | p.7 |
| Errataic or accelerated pump speed | Held open or worn piston valve or seal | Clear valve; replace seal. | p.7 |
| Errataic or accelerated pump speed | Held open or worn intake valve or seal. | Clear valve; replace seal. | p.7 |
| Pump operates, but output low on up stroke | Worn piston seal | Replace. | p.7 |
| Pump operates, but output low on up stroke | Damaged upper check seat | Replace pump piston. | p.7 |
| Pump operates, but output low on down stroke | Worn fluid intake seal | Replace. | p.7 |
| Pump operates, but output low on down stroke | Damaged lower check seat | Replace shovel rod. | p.7 |
| Pump operates, but output low on both strokes | Inadequate air supply pressure or restricted air lines | Increase air supply and/or clear restriction. | p.7 |
| Pump operates, but output low on both strokes | Closed or clogged pump valves | Open and/or clean. | p.7 |
| Pump operates, but output low on both strokes | Exhausted fluid supply | Refill fluid supply, and reprime pump. | p.7 |
| Pump operates, but output low on both strokes | Clogged fluid line, hose, valve, or other accessory | Relieve pressure. Clear obstruction. | p.7 |
| Pump operates, but output low on both strokes | Worn seals | Replace. | p.7 |
| Grease leaking from muffler plates | Worn throat seal | Replace. | p.7 |