Caution Symbol
his symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before you operate this equipment.
Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
Do not modify this equipment.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 8400 psi (58 MPa, 580 bar) maximum working pressure at 140 psi (0.97 MPa, 9.7 bar) maximum incoming air pressure.
Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Handle hoses carefully. Do not pull on hoses to move equipment.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 66C (150F) or below –40C (–40F).
Do not move or lift pressurized equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Fluid from the dispensing valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.
Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medical attention.
Do not point the dispensing valve at anyone or at any part of the body.
Do not put your hand or fingers over the end of the dispensing valve.
Do not stop or deflect leaks with your hand, body, glove or rag.
Use only extensions and no-drip tips which are designed for use with your dispensing valve.
Do not use a low pressure flexible nozzle with this equipment.
Follow the Pressure Relief Procedure on page 7 if the grease fitting coupler clogs and before you clean or service this equipment.
Tighten all fluid connections before you operate this equipment.
Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.
Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.
Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
Ground the equipment and the object being dispensed to. Refer to Grounding below.
If there is any static sparking or you feel an electric shock while using this equipment, stop dispensing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed.
Keep the dispensing area free of debris, including solvent, rags, and gasoline.
Do not smoke in the dispensing area.
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
Do not operate the pump with the air motor plates removed.
Keep clear of all moving parts when you start or operate the pump.
Before you service this equipment, follow the Pressure Relief Procedure on page 7 to prevent the equipment from starting unexpectedly.

Proper grounding is an essential part of maintaining a safe system.
To ground the pump, loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm) minimum ground wire (Y) into the slot in lug (Z), and tighten the locknut securely. Connect the other end of the wire to a true earth ground. To order a ground wire and clamp, order Part No. 222011.
To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
Ground all of this equipment:
Pump: Use a ground wire and clamp as shown in Fig. 1.
Air and fluid hoses: Use only electrically conductive hoses.
Air compressor: Follow the manufacturer’s recommendations.
Fluid supply container: Follow the local code.
To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the valve firmly to the side of a grounded metal pail, then trigger the valve.
G
Recommended air line configuration to reduce moisture in pump
KEY
J
J
E F
A Fluid dispense line B Pump ground wire (required) C Air regulator with gauge D Main air supply line E Air line filter F Air line lubricator G Pump runaway valve H Follower plate J Bleed-type Master Air Valves (required) K Fluid drain valve
H
1/2 in.
Mount the pump securely so that it cannot move around during operation. Failure to do so could result in personal injury or equipment damage.
For Stationary Mountings ·

Air and Fluid Line and Accessories See Fig. 2 above.
Three accessories are required in your system: an air shut-off valve/air bleed device, fluid drain valve, and ground wire. These accessories help reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, injury from moving parts if you are adjusting or repairing the pump, and explosion from static sparking.
The air bleed device relieves air trapped between it and the air motor after the air supply is shut off. Trapped air can cause the air motor to cycle unexpectedly, causing serious injury if you are adjusting or repairing the pump. Use a bleed-type master air valve (J). Install them near the pump air inlet within easy reach from the pump.
The fluid drain valve (K) assists in relieving fluid pressure in the displacement pump, hoses, and dispensing valve. Triggering the valve to relieve pressure may not be sufficient.
The ground wire (B) reduces the risk of static sparking.
Do not hang the air accessories directly on the air inlet. The fittings are not strong enough to support the accessories and may cause one or more to break. Provide a bracket on which to mount the accessories.

COMPONENT RUPTURE HAZARD The maximum working pressure of each component in the system may not be the same. To reduce the risk of overpressurizing any component in the system, be sure you know the maximum working pressure of each component. Never exceed the maximum working pressure of the lowest rated component in the system. Overpressurizing any component can result in rupture, fire, explosion, property damage, and serious injury.
INJECTION HAZARD The equipment stays pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, fluid from the valve or splashing fluid, follow this procedure whenever you
Are instructed to relieve pressure Stop dispensing Check, clean or service any system equipment Install or clean dispensing devices
The pump has a rated ratio of 50:1. However, it is capable of reaching stall pressures equal to 60 times the air input pressure. Calculate the fluid output pressure using the air regulator reading. Multiply the air pressure shown on the regulator gauge by 60. For example:
140 psi air x 60 = 8400 psi fluid output
0.97 MPa air x 60 = 58.2 MPa fluid output
9.7 bar air x 60 = 582 bar fluid output
Regulate air to the pump so that no air line or fluid line component or accessory is overpressurized.
A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump accelerates quickly, or is running too fast, stop it immediately and check the material supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with material, or flush it and leave it filled with a compatible solvent. Be sure to elimi- nate all air from the material lines.



MOVING PARTS HAZARD Never operate the pump with the warning plate or the identification plate removed. These plates protect your fingers from pinching or amputation by moving parts in the air motor.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.
Relieve pressure before you check or service any system equipment.


Be sure you have all necessary parts on hand before you start. If using a repair kit, use all the parts in the kit for the best results.
Displacement Pump Repair Kit 241623 is available. Parts included in the kit are marked with a dagger () in the parts drawing and list.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.
Torque the shovel rod (58) to the piston (52) at 25 to 30 ft-lb (34 to 41 N-m), and torque piston (52) to the extension rod (57) at 25 to 30 ft-lb (34 to 41 N-m).
To avoid damaging the shovel tube, do not use slots in the tube to tighten or loosen tube.


! " #$ ! $% &$'
" * #$ ! &$'
( ) *
*
% " * #$ ! $ &$'
·

Before you start, be sure you have all necessary parts on hand. Repair Kit 206728 is available for the motor. Use all the parts in the kit for the best results. Parts included in the kit are marked with an asterisk (*) in the parts drawing and list.
Two accessory tools should be ordered. Use Padded Pliers, 207579, to grip the trip rod without damaging its surface. Use Gauge, 171818, to ensure the proper clearance between the poppets and seat of the transfer valve.
To avoid damaging the cylinder wall, lift the cylinder straight up off of the piston. Never tilt the cylinder while you are removing it.
To reduce the risk of pinching or amputating your fingers, always keep fingers clear of the toggle assemblies (L). See Fig. 5.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.
In step 7, do not damage the plated surface of the trip rod (11). A damaged trip rod could cause erratic air motor operation. Use the special padded pliers, 207579, to grasp the rod.

Torque the extension tube (64) to the base (5) at 45 to 55 ft-lb (61 to 75 N-m).
+ Fig. 4


Cut off tops of poppets as indicated by dotted lines.

Model No. 239877, pail length Model No. 239887, 120-pound drum length Model No. 239888, 400-pound drum length
Air Motor Includes items 1 to 39
* The replacements for these parts are available in Repair Kit 206728. Purchase the kit separately.
The replacements for these parts are available in Repair Kit 241623. Purchase the kit separately.

· · )

Model No. 239877, pail length Model No. 239887, 120-pound drum length Model No. 239888, 400-pound drum length
Ref. No. Part No. Description Qty.
Ref. No. Part No. Description Qty.
A 238756 AIR MOTOR ASSEMBLY Model 239877 (includes items 1 to 39) 1 239886 AIR MOTOR ASSEMBLY Models 239887 and 239888 (includes items 1 to 39) 1 1* 236079 .VALVE, poppet (includes items 1a and 1b) 2 1a 160896 .STEM, valve 1 1b 170708 .POPPET, valve; urethane 1 2 160614 .PISTON, air motor 1 3 104582 .W ASHER, tab 1 4 104029 .LUG, grounding 1 5 241826 .BASE 1 6 114179 .SEAL, throat 1 7 162718 .ADAPTER; 3/8 npt(m) x 1/4 npt(f) 1 8 192541 .ROD, displacement 1 9* 160625 .O-RING, buna-N 1 10 160624 .O-RING, buna-N 1 11 203965 .ROD, trip 1 12* 158367 .GROMMET, rubber, air intake 2 13 172867 .ACTUATOR, valve 1 14 172866 .CLIP, spring 2 15 102975 .SCREW, rd hd mach; no. 6–32 x 0.25” (6.3 mm) 2 16* 170709 .POPPET, valve; urethane 2 17 160613 .CYLINDER, air motor 1 18 222499 .PLA TE, identification; with muffler 1 19 100078 .SCREW , hex head; no. 8–32 x 0.38 in. (10 mm) long. 12 20 222501 .PLA TE, warning; with muffler 1 21 101578 .SCREW, hex head; no. 8–32 x 0.38 in. (10 mm) long 6 22 158360 .YOKE, rod, trip 1 23 158362 .PIN, toggle 2 24* 160621 .O-RING, nitrile rubber 1 25 160623 .ARM, toggle 2 26 158364 .ROCKER, toggle 2 27 167585 .SPRING, helical compression 2 28 156698 .O-RING; buna-N 1 29a 164704 .HANDLE NUT, cylinder, cap Model 239877 1 29b 161435 .NUT, cylinder, cap Models 239887 and 239888 1 30* 160261 .NUT, adjusting 4 31* 160618 .LOCKWIRE, transfer valve 2 32 180233 .LABEL, warning 2 33 160932 .GASKET; copper 1 38 192537 .NUT, packing 1
52 196184 PISTON 1 53 196185 RETAINER, piston seal 1 54 114171 SEAL, piston 1 56 100065 BALL 2 57 192685 ROD, extension Model 239877 1 192684 ROD, extension Model 239887 1 192535 ROD, extension Model 239888 1 58 192540 ROD, shovel 1 59 192538 CYLINDER, pump 1 60 192533 SEAL, gasket 2 61 192534 BEARING, shovel rod 1 62 114178 SEAL, shovel rod 1 63 192531 CONNECTOR, tube 1 64 192682 TUBE, extension Model 239877 1 193760 TUBE, extension Model 239887 1 193758 TUBE, extension Model 239888 1 66 192660 SHOVEL 1 67 192539 TUBE, shovel 1 68 185220 PLATE, serial 1 74 112154 PIN, spring, straight 1
* The replacements for these parts are available in Repair Kit 206728. Purchase the kit separately.
The replacements for these parts are available in Repair Kit 241623. Purchase the kit separately.


Model 239888 400 lb drum size Model 239887 120 lb drum size Model 239877 pail length
grounding lug grounding lug
3/8 npt(f) air inlet 3/8 npt(f) air inlet
3/8 npt(f) air inlet
1/4 npt(f) fluid outlet 1/4 npt(f) fluid outlet
1/4 npt(f) fluid outlet
26.7” (678 mm) 17.5” (445 mm)
33.6” (853 mm)
Technical Data
Layout
Maximum working pressure 8400
(58 MPa, 580 bar) Fluid pressure ratio 50:1 Air operating range 30 to 140 psi
(0.3 to 0.97 MPa, 3 to 9.7 bar) Air consumption 22.8 cfm (0.638 m/min)
at 0.25 gpm (0.95 liter/min),
at 100 psi (0.7 MPa, 7 bar) Gallons (liters) per pump cycle 0.003 (0.0109) Maximum recommended pump speed 76 cycles/min
two or four 0.265” (7 mm) dia. holes on 5” (127 mm) bolt circle
0.22 gpm (0.82 liter/min) Wetted parts steel, brass, aluminum,
Delrin, nitrile rubber, polyurethane Sound pressure level (measured at 1 meter from unit) 77.8 dB(A) Sound power level (tested in accordance with ISO 9614–2) 85.6 dB(A) . . Approximate weight 22 lb (10 Kg)
3” (76.2 mm) dia.
Delrin Loctite is a registered trademark of the Loctite Corp.

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accor- dance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco warrants all Fire–Ball Grease Pumps to be free from defects in material and workmanship for a period of thirty years from date installed in service by the original purchaser. Normal wear of items such as packings or valve seats are not considered to be defects in material and workmanship.
One year Graco will provide parts and labor.
Two through thirty years Graco will replace defective parts only.
TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:
All written and visual data contained in this document reflect the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 www.graco.com PRINTED IN USA 308883 April 1999, Revised February 2000
1–800–533–9655 Toll Free ·
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate | Inadequate air supply pressure or restricted air lines | Increase air supply and/or clear restriction. | p.8 |
| Pump fails to operate | Closed or clogged pump valves | Open and/or clean. | p.8 |
| Pump fails to operate | Clogged fluid line, hose, valve, or other accessory | Relieve pressure. Clear obstruction. | p.8 |
| Pump fails to operate | Damaged air motor | Assess damage, and service air motor. | p.8 |
| Pump fails to operate | Exhausted fluid supply | Refill and reprime or flush. | p.8 |
| Continuous air exhaust | Worn or damaged air motor gasket or seal | Assess wear or damage, and service air motor. | p.8 |
| Erratic pump operation | Exhausted fluid supply | Refill and reprime or flush | p.8 |
| Erratic pump operation | Worn pump seals | Replace. | p.8 |
| Erratic pump operation | Damaged shovel tube | Replace. | p.8 |
| Erratic pump operation | Damaged check seat | Replace pump piston or shovel rod (or other dam- aged part). | p.8 |
| Pump operates, but output low on up stroke | Worn piston seal | Replace. | p.8 |
| Pump operates, but output low on up stroke | Damaged upper check seat | Replace pump piston. | p.8 |
| Pump operates, but output low on down stroke | Worn fluid intake seal | Replace. | p.8 |
| Pump operates, but output low on down stroke | Damaged lower check seat | Replace shovel rod. | p.8 |
| Pump operates, but output low on both strokes | Inadequate air supply pressure or restricted air lines | Increase air supply and/or clear restriction. | p.8 |
| Pump operates, but output low on both strokes | Closed or clogged pump valves | Open and/or clean. | p.8 |
| Pump operates, but output low on both strokes | Exhausted fluid supply | Refill fluid supply, and reprime pump. | p.8 |
| Pump operates, but output low on both strokes | Clogged fluid line, hose, valve, or other accessory | Relieve pressure. Clear obstruction. | p.8 |
| Pump operates, but output low on both strokes | Worn seals | Replace. | p.8 |
| Grease leaking from muffler plates | Worn throat seal | Replace. | p.8 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.