308–739

This manual contains important warnings and information. READ AND KEEP IT FOR REFERENCE.
quality counts.

Part No. 239–327, Series A 105 bar (10.5 MPa, 1500 psi) Maximum Fluid Working Pressure 7 bar (0.7 MPa, 100 psi) Maximum Air Input Pressure
Refer to page 2 for the Table of Contents.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 http://www.graco.com COPYRIGHT 1997, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001
First choice when


Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.
Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medi- cal attention.
Do not point the gun at anyone or at any part of the body.
Do not put your hand or fingers over the spray tip.
Do not stop or deflect leaks with your hand, body, glove or rag.
Do not “blow back” fluid; this is not an air spray system.
Always have the tip guard and the trigger guard on the gun when spraying.
Check the gun diffuser operation weekly. Refer to the gun manual.
Be sure the gun trigger safety operates before spraying.
Lock the gun trigger safety when you stop spraying.
Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve pres- sure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.
Tighten all fluid connections before operating the equipment.
Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose.
Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
Keep clear of all moving parts when starting or operating the pump.
Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.
Keep the spray area free of debris, including solvent, rags, and gasoline.
Electrically disconnect all equipment in the spray area.
Extinguish all open flames or pilot lights in the spray area.
Do not smoke in the spray area.
Do not turn on or off any light switch in the spray area while operating or if fumes are present.
Do not operate a gasoline engine in the spray area.
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.
Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

Pump: Use a ground wire and clamp. See Fig.1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. For a ground wire and clamp, order Part No. 237–569.
Reference numbers and letters in parentheses in the text refer to the callouts in the figures and drawings.
Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.

Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.
All persons who operate the equipment must be trained in the safe, efficient operation of all system components as well as the proper handling of all fluids. All operators must thoroughly read all instruction manuals, tags, and labels before operating the equipment.
Air and fluid hoses: Use only electrically conductive hoses with 150 m (500 ft) maximum combined hose length to ensure grounding continuity.
Ensure that you have an adequate compressed air supply. Refer to the performance chart on page 15 to find the air consumption of your pump.
Air compressor: Follow manufacturer’s recommendations.
Spray gun or dispensing valve: Connect to a properly grounded fluid hose and pump.
Keep the site clear of any obstacles or debris that could interfere with the operator’s movement.
Object being sprayed: Follow your local code.
Have a grounded, metal pail available for use when flushing the system.
Fluid supply container: Follow your local code.
Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.
Mount the pump (A) to suit the type of installation planned. The pump dimensions and mounting hole layout are shown on page 13. If you are using a wall bracket (B), check that the wall is strong enough to support the weight of the equipment, hoses, fluid, and stress caused when the pump is in operation. Mount the wall bracket 1.5 m (5 ft) above the floor.
To maintain proper grounding continuity when flushing or relieving pressure, always hold the metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 4.
·

KEY
A Pump B Wall bracket C Air line lubricator D Bleed-type master air valve (required for pump) See Warning on page 7 for part number. E Pump air regulator F Air line filter G Bleed-type master air valve (for accessories) H Electrically conductive air supply hose J Fluid drain valve (required) See Warning on page 7 for part numbers. K Fluid filter L Electrically conductive fluid supply hose M Spray gun N Fluid suction hose P Air line moisture trap and drain valve R Pump runaway valve Y Ground wire (required) Part No. 237–569. See page 5 for installation instructions
C D E
R
H
A
M
Y
B P
K
J
N
07198 Fig. 2

Install the following accessories in the order shown in Fig. 2, using adapters as necessary:
Air line lubricator (C) Provides automatic air motor lubrication.
A bleed-type master air valve (D) and a fluid drain valve (J) are required in your system. These accessories help reduce the risk of serious injury including fluid injection, splashing in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.
Bleed-type master air valve (D) Required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING at left). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator (E).
The bleed-type master air valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump. Order Part No. 113–333.
Air regulator (E) Controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the bleed-type master air valve (D).
The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient. Order one of the following:
Pump runaway valve (R) Senses if the pump is running too fast and shuts off the air supply to the motor. A pump which runs too fast can be seriously damaged.
Part No. Description
238–635 1/4 npt (mbe), carbon steel 210–657 1/4 npt (mbe), carbon steel 210–658 3/8 npt (mbe), carbon steel 210–659 1/4 npt x 3/8 npt (mbe), carbon steel 239–018 1/4 npt (mbe), stainless steel 235–992 1/4 npt x 3/8 npt (mbe), stainless steel
Air line filter (F) Install an air line filter (F) and a moisture trap and drain valve (P) to help remove moisture and contaminants from the compressed air supply.
Second bleed-type air valve (G) Isolates the air line accessories for servicing. Locate upstream from all other air line accessories.
Air and Fluid Hoses
Be sure all air and fluid hoses are properly sized and pressure-rated for your system. Use only electrically conductive air and fluid hoses. Use a 13 mm (1/2 in.) I.D. (minimum) air hose (H) to supply air to the pump.
Fluid Line Accessories Install the following accessories in the positions shown in Fig. 2, using adapters as necessary:
Fluid hoses must have spring guards on both ends. Connect a fluid hose (L) to the pump’s 3/8 npt(f) fluid outlet. Use of a short whip hose between the main fluid hose and the gun (M) allows freer gun movement. Connect a fluid suction hose or tube (N) to the pump’s 3/4 npt(m) fluid intake.
Fluid drain valve (J) Required in your system to relieve fluid pressure in the hose and gun (see the WARNING at left). Install the drain valve so that it points down and the handle points up when it is opened.
Fluid filter (K) Filters harmful particles from the fluid.
Spray gun (M) Dispenses the fluid. The gun shown in Fig. 2 is an airless spray gun.
Air Line Accessories ·

Packing Nut/Wet-Cup
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.
INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:
Keep the packing nut/wet-cup (V) filled with Graco Throat Seal Liquid (TSL) or compatible solvent to help prolong the packing life. Check the tightness of the packing nut weekly; tighten just enough to prevent leakage; do not overtighten it. See Fig. 3 on page 11. Relieve the pressure before adjusting the packing nut or adding TSL.
are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tip.
Begin these steps before you install the spray tip.
If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen it completely. Then clear the tip or hose.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.
The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using may be contaminated by the oil, flush it out with a compatible solvent before using the pump. If the pump is being used to supply a circulating system, allow the solvent to circulate until the pump is thoroughly flushed. See Flushing the Pump on page 9.

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause component rupture and serious injury, never exceed the specified maximum air input pressure to the pump (see Technical Data on page 14).
FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE AND EXPLOSION HAZARD on page 4. Be sure the entire system and flushing pails are properly grounded. Refer to Grounding on page 5.
Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency. Always flush the pump before fluid dries on the displacement rod.
Never leave water or water-base fluid in the pump overnight. If you are pumping water-base fluid, flush with water first, then with a rust inhibitor such as mineral spirits. Relieve the pressure, but leave the rust inhibitor in the pump to protect the parts from corrosion.
Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump accel- erates quickly, or is running too fast, stop it immedi- ately and check the fluid supply. If the supply con- tainer is empty and air has been pumped into the lines, refill the container and prime the pump and the lines with fluid, or flush and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
For overnight shutdown, relieve the pressure, and always stop the pump at the bottom of the stroke to prevent the fluid from drying on the exposed displacement rod and damaging the throat packings.
Always flush the pump before the fluid dries on the displacement rod. See Flushing the Pump.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
* To determine if the fluid hose or gun is obstructed, relieve the pressure and disconnect the fluid hose, and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump; about 1.4 to 2.8 bar (0.14 to 0.28 MPa, 20 to 40 psi). If the pump starts when the air is turned on, the obstruction is in the fluid hose or gun.

Reconnecting the Displacement Pump

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

Lubricate.
Torque to 20 to 27 Nm (15 to 20 ft-lb).


Ref Part No. No. Description Qty
1 205–997 AIR MOTOR see manual 307–043 1 2 223–587 DISPLACEMENT PUMP ASSY, see manual 306–981 1 3 164–722 ROD, tie; carbon steel; 111 mm (4.375 in.) shoulder to shoulder 3 4 101–566 NUT, lock, 3/8–16 3 5 101–946 PIN, cotter, stainless steel 1 6 154–771 O-RING; buna-N 1

Mounting Hole
Layout

A 111.3 mm (4.38 in.) diameter
B 64 mm (2.5 in.)
C 127 mm (5.0 in.)
D 7.1 mm (0.28 in.) diameter



Ratio 15:1
Maximum fluid working pressure 105 bar (10.5 MPa, 1500 psi)
Maximum air input pressure 7 bar (0.7 MPa, 100 psi)
Fluid flow at 60 cycles per minute 1.9 liters/min (0.5 gpm)
Maximum pump operating temperature 82C (180F)
Wetted parts Refer to manual 306–981.
Sound Pressure Levels (dBa) (measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
Air Motor 2.8 bar (0.28 MPa, 40 psi) 4.8 bar (0.48 MPa, 70 psi) 7 bar (0.7 MPa, 100 psi)
Monark 73.3 dB(A) 75.9 dB(A) 77.7 dB(A)
Sound Power Levels (dBa) (tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
Air Motor 2.8 bar (0.28 MPa, 40 psi) 4.8 bar (0.48 MPa, 70 psi) 7 bar (0.7 MPa, 100 psi)
Monark 87.0 dB(A) 89.7 dB(A) 91.4 dB(A)
Category Data ·

19 37 54 71 88 60 scfm m/min
A 7 bar (0.7 MPa, 100 psi) Air Pressure B 4.9 bar (0.49 MPa, 70 psi) Air Pressure C 2.8 bar (0.28 MPa, 40 psi) Air Pressure
104, 10.4
25 0.70
87, 8.7
To find fluid outlet pressure (bar/MPa/psi) at a specific fluid flow (lpm/gpm) and operating air pressure (bar/MPa/psi):
A
15 0.42
51, 5.1
To find pump air consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (bar/MPa/psi):
34, 3.4
17, 1.7
gpm liters/minute 0.8 1.5 2.3 3.0 3.8

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you: 1–800–367–4023 Toll Free
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Sales Offices: Minneapolis, Detroit, Los Angeles Foreign Offices: Belgium, Canada, England, Korea, France, Germany, Hong Kong, Japan
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 http://www.graco.com PRINTED IN U.S.A. 308–739 September 1997
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate. | Restricted line or inadequate air supply. | Clear; increase air supply. | p.10 |
| Pump fails to operate. | Insufficient air pressure; closed or clogged air valves, etc. | Open; clean (be sure to use air fil- ter). | p.10 |
| Pump fails to operate. | Exhausted fluid supply. | Refill; purge all air from pump and fluid lines. | p.10 |
| Pump fails to operate. | Damaged air motor. | Service air motor. See manual 307–043. | p.10 |
| Pump fails to operate. | Dried fluid seizure of displacement rod. | Clean, check or replace throat pack- ings. See manual 306–981. Always stop pump at bottom of stroke and keep wet-cup filled with compatible solvent. | p.10 |
| Pump operates but output is low on both strokes. | Restricted line or inadequate air supply. | Clear; increase air supply. | p.10 |
| Pump operates but output is low on both strokes. | Insufficient air pressure; closed or clogged air valves, etc. | Open; clean (be sure to use air filter). | p.10 |
| Pump operates but output is low on both strokes. | Clogged fluid line, valves, etc. | Clear* (be sure to use fluid filter). | p.10 |
| Pump operates but output is low on both strokes. | Packing nut is too tight. | Loosen (see page 8). | p.10 |
| Pump operates but output is low on downstroke. | Held open or worn intake valve. | Clear; service. See manual 306–981. | p.10 |
| Pump operates but output is low on upstroke. | Held open or worn fluid piston valve or packings. | Clear; service. See manual 306–981. | p.10 |
| Erratic or accelerated operation. | Exhausted fluid supply. | Refill; purge all air from pump and fluid lines. | p.10 |
| Erratic or accelerated operation. | Held open or worn intake valve. | Clear; service. See manual 306–981. | p.10 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.