1:1 RATIO TRITON 308 Diaphragm Pump
309303V
Used to pump waterborne and solvent–based paints and catalysts. For professional use only.
115 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure 115 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure
Part No. 233500 Aluminum Pump, Series D, npt threads Part No. 233501 Stainless Steel Pump, Series C, npt threads Part No. 233776 Aluminum Pump, Series C, BSPP threads Part No. 233777 Stainless Steel, Series C, BSPP threads
U.S. and Foreign Patents Pending
ti1029a Part No. 233501 Shown


Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 115 psi (0.8 MPa, 8 bar) maximum working pressure at 115 psi (0.8 MPa, 8 bar) maximum incoming air pressure.
Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Aluminum pumps only: Never use 1.1.1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.
Do not use hoses to pull equipment.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 180F (82C) or below –40F (–40C).
Wear hearing protection when operating this equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.
309303 3

Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury.
Ground the equipment. Refer to Grounding on page 7.
If there is any static sparking or you feel an electric shock while using this equipment, stop pump- ing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being pumped.
Keep the work area free of debris, including solvent, rags, and gasoline.
Electrically disconnect all equipment in the work area.
Extinguish all open flames or pilot lights in the work area.
Do not smoke in the work area.
Do not turn on or off any light switch in the work area while operating or if fumes are present.
Do not operate a gasoline engine in the work area.
4 309303

Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury.
Do not stop or deflect fluid leaks with your hand, glove, or rag.
Follow the Pressure Relief Procedure on page 11 before cleaning, checking, or servicing the equipment.
Tighten all fluid connections before each use.
Check the hoses, tubes, and couplings daily. Replace parts immediately if worn, damaged, or loose. Permanently coupled hoses cannot be repaired.
Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled.
Know the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings.
Store hazardous fluid in an approved container. Dispose of the hazardous fluid according to all local, state, and national guidelines.
Wear appropriate protective clothing, gloves, eyewear, and respirator.
If the diaphragm fails, the fluid is exhausted along with the air.
309303 5

Fig. 2 shows a wall mounted HVLP spray applica- tion. It is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.
FIRE AND EXPLOSION HAZARD To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Never operate the spray gun unless ventilation fans are operating.
Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.
Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.
Use a compatible, liquid thread sealant on all male threads. Tighten all connections firmly to avoid air or fluid leaks. NOTE: On all npt threads, tighten to 2–3 turns past finger tight.
TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Reference numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages 23–22.
In a spray system, ventilate the spray booth.
Mounting the Pump
Mount the pump in a well-ventilated area, with sufficient clearance on all sides for operator access and servicing.
See the Service section for torque specifications.
Be sure the mounting can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.
After unpacking the pump, and before using it for the first time, check and retorque all external fas- teners.
The pump may be mounted vertically or horizontal- ly. Be sure the pump is level in all directions.
After the first day of operation, retorque the fasten- ers.
Wall, pail, stand, or portable cart mounting kits are available from Graco. For other mountings, be sure the pump is adequately secured. The pump has two mounting holes for 0.35 in. (9 mm) screws. See the Dimension drawing on page 25.
As a general guideline, retorque fasteners every two months.
6 309303

Y 35
FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below. Also read the sec- tion FIRE AND EXPLOSION HAZARD on page 4.
To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equip- ment.
Air and fluid hoses: Use only electrically conductive hoses.
Air compressor: Follow the manufacturer’s recom- mendations.
Ground all of this equipment:
Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.
Pump: Attach a ground wire (Y) to the pump’s grounding screw (35) and secure with the screw, as shown in Fig. 1. Connect the clamp end of the ground wire to a true earth ground. Order Part No. 238909 Ground Wire and Clamp.
Fluid supply container: Follow your local code.
ti1030b · 309303 7

b. Locate a bleed-type master air valve (B) close to the pump, to relieve trapped air. See the WARNING at left. Locate another air valve (E) upstream from all air line accessories, to isolate them during cleaning and repair.
A bleed-type master air valve (B) is required in your system to relieve air trapped between this valve and the pump. See Fig. 2. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury, including splashing in the eyes or on the skin, injury from moving parts, or contamina- tion from hazardous fluids.
c. Install an air line filter (D) to remove harmful contaminants such as dirt, moisture, and oil from the compressed air supply.
a. The fluid pressure can be controlled in two ways, either by controlling the air into the pump with the air regulator (F) or the fluid out of the pump with the fluid regulator (H).
8 309303

KEY A TRITON 308 Pump B Bleed-type master air valve (required for pump) C Air supply line D Air line filter E Air line shutoff valve F Pump air regulator G Gun air regulator (used in spray system only) H Fluid pressure regulator (used in spray system only) J Drain/circulation valve K Drain tube L Suction tube M Pump fluid inlet N Pump fluid outlet P Fluid hose (shown connected to gun in spray system) R Gun air hose (used in spray system only) S Spray gun (used in spray system only) T Pump air inlet U Agitator (used in spray system only) V Air line quick disconnect Y Ground wire
H
Y
R
D E
J
P
B
U
Y
K
H J
N
K
G
T
F
A
M
B
ti1020a · ti1007a · 309303 9

CAUTION
Screw the suction line (L) into the pump inlet (M) snugly. Use a compatible liquid thread sealant on connections to prevent air from getting into the fluid line.
Some systems may require installation of a pressure relief valve at the pump outlet to prevent overpres- surization and rupture of the pump or hose.
Thermal expansion of fluid in the outlet line can cause overpressurization. This can occur when using long fluid lines exposed to sunlight or ambient heat, or when pumping from a cool to a warm area (for example, from an underground tank).
Do not pressure feed this pump.
See the Technical Data on page 24 for maximum suction lift.
Overpressurization can also occur if the pump is being used to feed fluid to a piston pump, and the intake valve of the piston pump does not close, causing fluid to back up in the outlet line.
Use an agitator (U) to prevent fluid from settling out. Part No. 245081 Agitator Kit (accessory) is available.
Use electrically conductive fluid hoses (P). Screw the fluid fitting into the pump outlet (N) snugly.
Install a fluid regulator (H) at the pump fluid outlet to control fluid pressure, if desired. See Air Line, step 1a, for another method of controlling pressure.
A fluid drain valve (J) is required in your system to relieve pressure in the hose if it is plugged. See Fig. 2. The drain valve reduces the risk of serious injury, including splashing in the eyes or on the skin, or contamination from hazardous fluids when relieving pressure. Install the valve close to the pump fluid outlet. To use the valve as a circulation valve, connect a tube (K) between the valve and pail.
Install a fluid drain valve (J) near the fluid outlet. See the WARNING at left.
The pump was tested in lightweight oil. If the oil could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. Follow the steps under Starting and Adjusting the Pump on page 11.
10 309303

The system remains pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the gun, or splashing of any fluid, follow this proce- dure whenever you
Stop spraying Are instructed to relieve pressure Check or service any system equipment Install, clean, or change spray nozzles
If you are flushing, run the pump long enough to thoroughly clean the pump and hoses. Close the air regulator. Remove the suction tube from the solvent and place it in the fluid to be pumped.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.
Be sure the pump is properly grounded. Read Fire and Explosion Hazard on page 4.
At the end of the work shift, flush the pump and relieve pressure.
309303 11

Storage
Before each use, check all hoses for wear or damage. Replace as necessary. Check that all threaded con- nections are tight and leak-free. NOTE: Periodically, re–torque fluid cover screws (38) to 10 ft–lb (13.6 Nm).
Before storing the pump, always flush it and relieve pressure.
Establish a preventive maintenance schedule, based on the pump’s service history. This is especially impor- tant for prevention of spills or leakage due to dia- phragm failure.
Clean the outside of the equipment daily, using a soft cloth and compatible solvent.
Clean the suction tube (L) and inlet strainer daily, using a compatible solvent.
Clean the air filter (D) in your main air line at least once a week.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.
12 309303

Pump runs sluggishly. Worn or damaged carriage o-rings. Service air valve. See page 18.
Pump runs erratically. Clogged suction line or inlet strainer. Clear.
Sticking or leaking ball check valves.
Disassemble and clean ball checks. Replace worn parts. See page 16.
Pump runs too fast. Exhausted fluid supply. Refill fluid supply and prime pump.
Pump cycles at stall or fails to hold pressure at stall.
Worn ball check valves. Disassemble and clean ball checks. Replace worn parts. See page 16.
Audible air leak. Worn air valve cup or plate. Service air valve. See page 18.
Air exhausting from the mounting holes.
Fluid covers are installed incorrectly. Align mounting holes in fluid covers with holes in center housing. See page 14.
Fluid in the exhaust air. Ruptured diaphragm. Replace diaphragms. See page 17.
Air bubbles in fluid. Loose suction line. Tighten. Use a compatible liquid thread sealant on connections.
Ruptured diaphragm. Replace diaphragms. See page 17.
Poor finish or irregular spray pat- tern.
Incorrect fluid or air pressure at gun. See gun manual; read fluid
manufacturer’s recommendations. Use fluid regulator.
Fluid is too thin or too thick. Adjust fluid viscosity; read fluid manufacturer’s recommendations.
Dirty, worn, or damaged spray gun. Service gun.
Fluid is settling out. Use agitator. Order Part No. 245081 Agitator Kit.
309303 13

2.5 mm allen wrench
Be careful that the ball checks do not fall out when you remove the fluid covers (32).
6 mm allen wrench
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

10 ft-lb (13.6 Nm) Align
28 in-lb (3.1 Nm)
4 Replace seals whenever cover (32) is removed.
ti1031a Fig. 3
Reassembly · 31, 29 · 309303 15

Tools Required O-ring pick
Disassembly NOTE: Ball Check Repair Kit 245067 is available. Parts included in the kit are marked with a double dagger, for example (21). Use all the parts in the kit for the best results.
10 ft-lb (13.6 Nm)

Adjustable wrench, or vise
Wear gloves when removing the diaphragms to reduce the risk of cuts.
10 ft-lb (13.6 Nm)
Use M8 bolt and nut to keep shaft from turning. 2

3 mm allen wrench
Retaining ring removal tool
Orient “POM” marking on air valve plate as shown in relation to fluid outlet arrow.
ti15226a Fig. 6

2 10 9 11
28 in-lb (3.1 Nm)
Align. See Fig. 6.
14 15

Retaining ring removal tool
Vise with soft jaws
Do not grip the shaft with tools that can scratch or damage the shaft, such as wrenches or pliers.


309303 21

Part No. 233501 Stainless Steel Pump, Series C, npt threads (Shown)
Part No. 233776 Aluminum Pump, Series C, BSPP threads
Part No. 233777 Stainless Steel Pump, Series C, BSPP threads

ti1036F · 22 309303

Ref. No. Part No. Description Qty.
Ref. No. Part No. Description Qty.
1 15J732 HOUSING, center; for Part No. 233500; aluminum 1 198894 HOUSING, center; for Part No. 233501; stainless steel 1 198892 HOUSING, center; for Part No. 233776; aluminum 1 197679 HOUSING, center; for Part No. 233777; stainless steel 1 3 197645 CARRIAGE, valve 1 4 197646 RING, retaining, shaft 2 5 n/a SHAFT, diaphragm 1 6* 197648 DIAPHRAGM; PTFE composite 2 7 197649 CARRIAGE 1 8 197650 O-RING, carriage 2 9 197651 PLUG, carriage 2 10 197652 O-RING, plug 2 11 197653 RING, retaining, carriage 2 12 197654 CUP, valve, air 1 13 197655 PLATE, valve, air 1 14 197656 O-RING, valve, air 2 15 197657 O-RING, valve, air 1 16 197658 GASKET, valve, air 1 17 197659 COVER, valve, air 1 18 197660 VALVE, safety, air 1 19 197661 PLATE, dampener; neoprene 1 20 197662 DAMPENER; steel 1 21 197663 BALL; acetal 4 22 197664 SEAL, valve, outlet; acetal 2 23 197665 SEAT, valve, outlet; stainless steel 2 24* 197666 SEAL, ball check; nylon 4 25 197667 O-RING, valve, inlet; fluoroelastomer 2 26 197668 SEAT, valve, inlet; stainless steel 2 27 197669 GUIDE, ball; acetal 4 28 197670 DAMPENER, felt, air inlet side 1 29 197671 DAMPENER, felt, side 1 30 16A659 COVER, air inlet side 1 31 16A661 COVER, side 1
32 197674 COVER, housing; for Part Nos. 233500 and 233776; aluminum 2 197680 COVER, housing; for Part Nos. 233501 and 233777; stainless steel 2 33 198832 FITTING, air inlet; for Part Nos. 233500 and 233501 1 198831 FITTING, air inlet; for Part Nos. 233776 and 233777 1 35 116343 SCREW, grounding; M5 x 10 1 36 116474 SCREW, cap, socket-hd; M4 x 20 4 37 116475 SCREW, cap, socket-hd; M4 x 12 2 38 117367 SCREW, cap, socket-hd; M8 x 18; for Part Nos. 233500 and 233776 12 15D128 SCREW, same as above; for Part Nos. 233501 and 233777 12 39 116595 SCREW, button-hd; M4 x 12 2 40 188621 LABEL, warning 1 43 157628 O–RING 2 44 n/a BEARING 2 45 n/a O–RING, nitrile 2 46 n/a O–RING, nitrile 2 47 n/a RING, retaining 2
* These parts are only available by purchasing Dia- phragm Repair Kit 245065.
These parts are only available by purchasing Air Valve Repair Kit 245066.
These parts are only available by purchasing Ball Check Repair Kit 245067.
These parts are only available by purchasing Shaft
and Bearing Repair Kit 24A155.
Replacement Danger and Warning labels, tags and
cards are available at no cost.
This part available in 10–pack kit 15D564 or in Ball
Check Repair kit 245067
309303 23


Air pressure operating range 12 to 115 psi (.08 to 0.8 MPa, 0.8 to 8.0 bar)
50 to 176 C (10 to 80 C)
Maximum suction lift 16 ft (4.8 m) dry; 22 ft (6.5 m) wet
Wetted parts Part Nos. 233500, 233776: Aluminum, Stainless Steel, Acetal, Nylon, PTFE,
Sound Pressure Levels in dB(A)*
Sound Power Levels in dB(A)* (tested in accordance with ISO 3744)
(measured at 1 m from unit)
Input Air Pressures Sound Pressure
Input Air Pressures Sound Power
40 psi (0.28 MPa, 2.8 bar) 69.1
40 psi (0.28 MPa, 2.8 bar) 80.8
60 psi (0.42 MPa, 4.2 bar) 72.1
60 psi (0.42 MPa, 4.2 bar) 83.7
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):
To find Pump Air Consumption (l/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):
A 115 psi (0.8 MPa, 8 bar) air pressure B 90 psi (0.6 MPa, 6 bar) air pressure C 60 psi (0.4 MPa, 4 bar) air pressure D 30 psi (0.2 MPa, 2 bar) air pressure
scfm l/min
24 47 71 cycles per minute
94 141 165 188


0.8, 8.0
FLUID PRESSURE
0.7, 7.0
0.4, 4.0
0.3, 3.0
0.14, 1.4
0 1 2 3 4 5 6 7 8
gpm l/min 22.8 7.6 11.4
0 1 2 3 4 5 6 7 8
gpm l/min 22.8 7.6 11.4
3.8 15.2 19.0 26.6
3.8 15.2 19.0 26.6

4.53 in. (115 mm)
3/8 npt or 3/8 BSPP Fluid Outlet
Two 0.35 in. (9 mm) diameter holes, for mounting pump
1/4 npt or 1/4 BSPP Air Inlet
3/4 npt or M26 x 1.5 Fluid Inlet
4.1 in. (104 mm)
SIDE VIEW
SST
4.88 in. (124 mm)
9.1 in. (231.5 mm)
8.2 in. (208 mm)
Aluminum · ti1037a · 309303 25

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor, or call one of these numbers
to identify the distributor closest to you:
1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 309303
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 2001, Graco Inc. is registered to ISO 9001
Revised 02/2011 · 26 309303
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump will not run. | Closed air line valve. | Open valve. | p.12 |
| Pump will not run. | Inadequate air supply, or clogged/ restricted air line. | Increase air supply. Do not exceed maximum air inlet pressure. | p.12 |
| Pump will not run. | Open or clear air line. | p.12 | |
| Pump will not run. | Clean air filter. | p.12 | |
| Pump will not run. | Clogged pump, fluid line, or spray gun. | Clear, service. Flush regularly. Do not allow fluid to set up in the pump and lines. | p.12 |
| Pump will not run. | Stuck or damaged pump air valve. | Disassemble and clean air valve. Replace worn parts. See page 18. Use filtered air. | p.12 |
| Pump will not run. | Ruptured diaphragm. | Replace diaphragms. See page 17. | p.12 |
| Pump will not run. | Air valve plate installed incorrectly. | Align plate with center housing. See page 19. | p.12 |
| Pump runs sluggishly. | Worn or damaged carriage o-rings. | Service air valve. See page 18. | p.13 |
| Pump runs erratically. | Clogged suction line or inlet strainer. | Clear. | p.13 |
| Pump runs erratically. | Sticking or leaking ball check valves. | Disassemble and clean ball checks. Replace worn parts. See page 16. | p.13 |
| Pump runs too fast. | Exhausted fluid supply. | Refill fluid supply and prime pump. | p.13 |
| Pump cycles at stall or fails to hold pressure at stall. | Worn ball check valves. | Disassemble and clean ball checks. Replace worn parts. See page 16. | p.13 |
| Audible air leak. | Worn air valve cup or plate. | Service air valve. See page 18. | p.13 |
| Air exhausting from the mounting holes. | Fluid covers are installed incorrectly. | Align mounting holes in fluid covers with holes in center housing. See page 14. | p.13 |
| Fluid in the exhaust air. | Ruptured diaphragm. | Replace diaphragms. See page 17. | p.13 |
| Air bubbles in fluid. | Loose suction line. | Tighten. Use a compatible liquid thread sealant on connections. | p.13 |
| Air bubbles in fluid. | Ruptured diaphragm. | Replace diaphragms. See page 17. | p.13 |
| Poor finish or irregular spray pat- tern. | Incorrect fluid or air pressure at gun. | See gun manual; read fluid manufacturer’s recommendations. Use fluid regulator. | p.13 |
| Poor finish or irregular spray pat- tern. | Fluid is too thin or too thick. | Adjust fluid viscosity; read fluid manufacturer’s recommendations. | p.13 |
| Poor finish or irregular spray pat- tern. | Dirty, worn, or damaged spray gun. | Service gun. | p.13 |
| Poor finish or irregular spray pat- tern. | Fluid is settling out. | Use agitator. Order Part No. 245081 Agitator Kit. | p.13 |