EN
Graco logo
Official user manual

Graco 233777

26 pages·440 KB·Heat Pump·PDF·ENDEFRITNLJA
Graco 233777
Table of Contents 63 sections Instructions–Parts List · 1:1 RATIO TRITON 308 Diaphragm Pump · 309303V · Table of Contents · … ShowHide
Page 1 of the Graco 233777 user manual — Instructions–Parts List
Page 1 · click to enlarge
Page 1

Instructions–Parts List

1:1 RATIO TRITON 308 Diaphragm Pump

309303V

Used to pump waterborne and solvent–based paints and catalysts. For professional use only.

115 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure 115 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure

Part No. 233500 Aluminum Pump, Series D, npt threads Part No. 233501 Stainless Steel Pump, Series C, npt threads Part No. 233776 Aluminum Pump, Series C, BSPP threads Part No. 233777 Stainless Steel, Series C, BSPP threads

U.S. and Foreign Patents Pending

ti1029a Part No. 233501 Shown

Page 2 of the Graco 233777 user manual — Table of Contents
Page 2 · Contents
Contents

Contents

Page 3 of the Graco 233777 user manual — INSTRUCTIONS
Page 3 · click to enlarge
Page 3

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury.

INSTRUCTIONS

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 115 psi (0.8 MPa, 8 bar) maximum working pressure at 115 psi (0.8 MPa, 8 bar) maximum incoming air pressure.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Aluminum pumps only: Never use 1.1.1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.

Do not use hoses to pull equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 180F (82C) or below –40F (–40C).

Wear hearing protection when operating this equipment.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

309303 3

Page 4 of the Graco 233777 user manual — FIRE AND EXPLOSION HAZARD
Page 4 · click to enlarge
Page 4

FIRE AND EXPLOSION HAZARD

Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury.

Ground the equipment. Refer to Grounding on page 7.

If there is any static sparking or you feel an electric shock while using this equipment, stop pump- ing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being pumped.

Keep the work area free of debris, including solvent, rags, and gasoline.

Electrically disconnect all equipment in the work area.

Extinguish all open flames or pilot lights in the work area.

Do not smoke in the work area.

Do not turn on or off any light switch in the work area while operating or if fumes are present.

Do not operate a gasoline engine in the work area.

4 309303

Page 5 of the Graco 233777 user manual — TOXIC FLUID HAZARD
Page 5 · click to enlarge
Page 5

PRESSURIZED FLUID HAZARD

Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury.

Do not stop or deflect fluid leaks with your hand, glove, or rag.

Follow the Pressure Relief Procedure on page 11 before cleaning, checking, or servicing the equipment.

Tighten all fluid connections before each use.

Check the hoses, tubes, and couplings daily. Replace parts immediately if worn, damaged, or loose. Permanently coupled hoses cannot be repaired.

TOXIC FLUID HAZARD

Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled.

Know the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings.

Store hazardous fluid in an approved container. Dispose of the hazardous fluid according to all local, state, and national guidelines.

Wear appropriate protective clothing, gloves, eyewear, and respirator.

If the diaphragm fails, the fluid is exhausted along with the air.

309303 5

Page 6 of the Graco 233777 user manual — Tightening Threaded Fasteners Before First Use
Page 6 · click to enlarge
Page 6

Installation

General Information

Fig. 2 shows a wall mounted HVLP spray applica- tion. It is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.

FIRE AND EXPLOSION HAZARD To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Never operate the spray gun unless ventilation fans are operating.

Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.

Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.

Use a compatible, liquid thread sealant on all male threads. Tighten all connections firmly to avoid air or fluid leaks. NOTE: On all npt threads, tighten to 2–3 turns past finger tight.

TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Reference numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages 23–22.

1. Read TOXIC FLUID HAZARD on page 5.
2. Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

In a spray system, ventilate the spray booth.

Tightening Threaded Fasteners Before First Use

Mounting the Pump

Mount the pump in a well-ventilated area, with sufficient clearance on all sides for operator access and servicing.

See the Service section for torque specifications.

Be sure the mounting can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.

After unpacking the pump, and before using it for the first time, check and retorque all external fas- teners.

The pump may be mounted vertically or horizontal- ly. Be sure the pump is level in all directions.

After the first day of operation, retorque the fasten- ers.

Wall, pail, stand, or portable cart mounting kits are available from Graco. For other mountings, be sure the pump is adequately secured. The pump has two mounting holes for 0.35 in. (9 mm) screws. See the Dimension drawing on page 25.

As a general guideline, retorque fasteners every two months.

6 309303

Page 7 of the Graco 233777 user manual — Grounding
Page 7 · click to enlarge
Page 7

Installation

Grounding

Y 35

FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below. Also read the sec- tion FIRE AND EXPLOSION HAZARD on page 4.

To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equip- ment.

Air and fluid hoses: Use only electrically conductive hoses.

Air compressor: Follow the manufacturer’s recom- mendations.

Ground all of this equipment:

Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

Pump: Attach a ground wire (Y) to the pump’s grounding screw (35) and secure with the screw, as shown in Fig. 1. Connect the clamp end of the ground wire to a true earth ground. Order Part No. 238909 Ground Wire and Clamp.

Fluid supply container: Follow your local code.

ti1030b · 309303 7

Page 8 of the Graco 233777 user manual — Air Line
Page 8 · click to enlarge
Page 8

Installation

Air Line

b. Locate a bleed-type master air valve (B) close to the pump, to relieve trapped air. See the WARNING at left. Locate another air valve (E) upstream from all air line accessories, to isolate them during cleaning and repair.

A bleed-type master air valve (B) is required in your system to relieve air trapped between this valve and the pump. See Fig. 2. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury, including splashing in the eyes or on the skin, injury from moving parts, or contamina- tion from hazardous fluids.

c. Install an air line filter (D) to remove harmful contaminants such as dirt, moisture, and oil from the compressed air supply.

2. The air valve does not require lubrication.
1. Install the air line accessories as shown in Fig. 2. Mount these accessories on the wall or on a bracket. Be sure the air line supplying the accessories is electrically conductive.
3. Install an electrically conductive, flexible air hose (C) between the accessories and the pump air inlet (T). Use a minimum 1/4” (6.3 mm) ID air hose. Screw an air line quick disconnect coupler (V) onto the end of the air hose and screw the mating fitting into the pump air inlet snugly. Do not connect the coupler to the fitting yet.

a. The fluid pressure can be controlled in two ways, either by controlling the air into the pump with the air regulator (F) or the fluid out of the pump with the fluid regulator (H).

8 309303

Page 9 of the Graco 233777 user manual — S
Page 9 · click to enlarge
Page 9

Installation

Wall Mount HVLP Spray Installation Shown

KEY A TRITON 308 Pump B Bleed-type master air valve (required for pump) C Air supply line D Air line filter E Air line shutoff valve F Pump air regulator G Gun air regulator (used in spray system only) H Fluid pressure regulator (used in spray system only) J Drain/circulation valve K Drain tube L Suction tube M Pump fluid inlet N Pump fluid outlet P Fluid hose (shown connected to gun in spray system) R Gun air hose (used in spray system only) S Spray gun (used in spray system only) T Pump air inlet U Agitator (used in spray system only) V Air line quick disconnect Y Ground wire

S

H

Y

R

D E

J

P

B

U

Y

K

H J

N

K

G

T

F

A

M

B

ti1020a · ti1007a · 309303 9

Page 10 of the Graco 233777 user manual — Flush the Pump Before First Use
Page 10 · click to enlarge
Page 10

Installation

Fluid Suction Line

CAUTION

Screw the suction line (L) into the pump inlet (M) snugly. Use a compatible liquid thread sealant on connections to prevent air from getting into the fluid line.

Some systems may require installation of a pressure relief valve at the pump outlet to prevent overpres- surization and rupture of the pump or hose.

Thermal expansion of fluid in the outlet line can cause overpressurization. This can occur when using long fluid lines exposed to sunlight or ambient heat, or when pumping from a cool to a warm area (for example, from an underground tank).

Do not pressure feed this pump.

See the Technical Data on page 24 for maximum suction lift.

Overpressurization can also occur if the pump is being used to feed fluid to a piston pump, and the intake valve of the piston pump does not close, causing fluid to back up in the outlet line.

Use an agitator (U) to prevent fluid from settling out. Part No. 245081 Agitator Kit (accessory) is available.

Use electrically conductive fluid hoses (P). Screw the fluid fitting into the pump outlet (N) snugly.

Fluid Outlet Line

Install a fluid regulator (H) at the pump fluid outlet to control fluid pressure, if desired. See Air Line, step 1a, for another method of controlling pressure.

A fluid drain valve (J) is required in your system to relieve pressure in the hose if it is plugged. See Fig. 2. The drain valve reduces the risk of serious injury, including splashing in the eyes or on the skin, or contamination from hazardous fluids when relieving pressure. Install the valve close to the pump fluid outlet. To use the valve as a circulation valve, connect a tube (K) between the valve and pail.

Install a fluid drain valve (J) near the fluid outlet. See the WARNING at left.

Flush the Pump Before First Use

The pump was tested in lightweight oil. If the oil could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. Follow the steps under Starting and Adjusting the Pump on page 11.

10 309303

Page 11 of the Graco 233777 user manual — Pump Shutdown
Page 11 · click to enlarge
Page 11

Operation

Pressure Relief Procedure

4. Check all fittings to be sure they are tight. Use a compatible liquid thread sealant on all male threads. Tighten the fluid inlet and outlet fittings snugly. Do not overtighten the fittings. NOTE: Before using he pump, re–torque fluid cover screws (38) to 10 ft–lb (13.6 N m).

The system remains pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the gun, or splashing of any fluid, follow this proce- dure whenever you

5. Place the suction tube (L, if used) in the fluid to be pumped.

Stop spraying Are instructed to relieve pressure Check or service any system equipment Install, clean, or change spray nozzles

6. Place the fluid hose (P) in a container.
7. Close the drain/circulation valve (J).
8. Close the pump air regulator (F). Open all bleedtype master air valves (B, E).
1. Shut off the bleed-type air valve (B).
2. In a spray system, hold the gun (S) firmly against a grounded metal pail and trigger the gun to relieve the fluid pressure.
9. If the fluid hose has a dispensing device, hold it open while continuing with the following step. Slowly open the air regulator (F) until the pump starts to cycle. Allow the pump to cycle slowly until all air is pushed out of the lines and the pump is primed.
3. Place the drain tube (K) in a waste pail. Open the drain/circulation valve (J) to relieve any fluid pressure trapped in the system.

If you are flushing, run the pump long enough to thoroughly clean the pump and hoses. Close the air regulator. Remove the suction tube from the solvent and place it in the fluid to be pumped.

Starting and Adjusting the Pump

1. Read Toxic Fluid Hazard on page 5.

Pump Shutdown

2. If lifting the pump, follow the Pressure Relief Procedure above.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

Be sure the pump is properly grounded. Read Fire and Explosion Hazard on page 4.

At the end of the work shift, flush the pump and relieve pressure.

309303 11

Page 12 of the Graco 233777 user manual — Troubleshooting
Page 12 · click to enlarge
Page 12

Maintenance

Tightening Threaded Connections

Storage

Before each use, check all hoses for wear or damage. Replace as necessary. Check that all threaded con- nections are tight and leak-free. NOTE: Periodically, re–torque fluid cover screws (38) to 10 ft–lb (13.6 Nm).

Before storing the pump, always flush it and relieve pressure.

Preventive Maintenance Schedule

Establish a preventive maintenance schedule, based on the pump’s service history. This is especially impor- tant for prevention of spills or leakage due to dia- phragm failure.

Cleaning

Clean the outside of the equipment daily, using a soft cloth and compatible solvent.

Clean the suction tube (L) and inlet strainer daily, using a compatible solvent.

Clean the air filter (D) in your main air line at least once a week.

Troubleshooting

1. Relieve the pressure before checking or servicing the equipment.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

2. Check all possible problems and causes before disassembling the pump.
PROBLEMCAUSESOLUTION Pump will not run.Closed air line valve.Open valve. Inadequate air supply, or clogged/ restricted air line.Increase air supply. Do not exceed maximum air inlet pressure. Open or clear air line. Clean air filter. Clogged pump, fluid line, or spray gun.Clear, service. Flush regularly. Do not allow fluid to set up in the pump and lines. Stuck or damaged pump air valve.Disassemble and clean air valve. Replace worn parts. See page 18. Use filtered air. Ruptured diaphragm.Replace diaphragms. See page 17. Air valve plate installed incorrectly.Align plate with center housing. See page 19.

12 309303

Page 13 of the Graco 233777 user manual — PROBLEM CAUSE SOLUTION
Page 13 · click to enlarge
Page 13

Troubleshooting

PROBLEM CAUSE SOLUTION

Pump runs sluggishly. Worn or damaged carriage o-rings. Service air valve. See page 18.

Pump runs erratically. Clogged suction line or inlet strainer. Clear.

Sticking or leaking ball check valves.

Disassemble and clean ball checks. Replace worn parts. See page 16.

Pump runs too fast. Exhausted fluid supply. Refill fluid supply and prime pump.

Pump cycles at stall or fails to hold pressure at stall.

Worn ball check valves. Disassemble and clean ball checks. Replace worn parts. See page 16.

Audible air leak. Worn air valve cup or plate. Service air valve. See page 18.

Air exhausting from the mounting holes.

Fluid covers are installed incorrectly. Align mounting holes in fluid covers with holes in center housing. See page 14.

Fluid in the exhaust air. Ruptured diaphragm. Replace diaphragms. See page 17.

Air bubbles in fluid. Loose suction line. Tighten. Use a compatible liquid thread sealant on connections.

Ruptured diaphragm. Replace diaphragms. See page 17.

Poor finish or irregular spray pat- tern.

Incorrect fluid or air pressure at gun. See gun manual; read fluid

manufacturer’s recommendations. Use fluid regulator.

Fluid is too thin or too thick. Adjust fluid viscosity; read fluid manufacturer’s recommendations.

Dirty, worn, or damaged spray gun. Service gun.

Fluid is settling out. Use agitator. Order Part No. 245081 Agitator Kit.

309303 13

Page 14 of the Graco 233777 user manual — CAUTION
Page 14 · click to enlarge
Page 14

Remove the Fluid and Side Covers

3. Remove the pump from its mounting.

CAUTION

2.5 mm allen wrench

Be careful that the ball checks do not fall out when you remove the fluid covers (32).

6 mm allen wrench

4. Remove the six screws (38) and top cover (32) from the center housing (1). Remove the ball check seals (24). Remove the bottom cover and seals.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

1. Relieve the pressure.
5. Remove the two screws (39) and take off the side cover (31) and felt dampener (29).
2. Disconnect the hoses and ground wire.
Show 5 more labels / short text on this page
Tools Required · Torque wrench · Adjustable wrench · Disassembly · 14 309303
Page 15 of the Graco 233777 user manual — H
Page 15 · click to enlarge
Page 15

Remove the Fluid and Side Covers (continued)

10 ft-lb (13.6 Nm) Align

28 in-lb (3.1 Nm)

4 Replace seals whenever cover (32) is removed.

1. Clean all parts and inspect for wear or damage. Replace parts as needed.
2. If necessary, reinstall the felt dampener (29) and side cover (31). Torque the screws (39) to 28 in-lb (3.1 N m).

H

3. Install new ball check seals (24).
4. Place the fluid covers (32) on the housing (1). Align the mounting holes (H) in the fluid covers with the holes in the housing. Install the screws (38) loosely, then torque oppositely and evenly to 10 ft-lb (13.6 N m).

H

5. Reinstall the pump on its mounting.
6. Reconnect the ground wire and hoses.

H

ti1031a Fig. 3

Reassembly · 31, 29 · 309303 15

Page 16 of the Graco 233777 user manual — Ball Check Repair
Page 16 · click to enlarge
Page 16

Ball Check Repair

Tools Required O-ring pick

1. Reinstall the inlet and outlet ball checks on one side of the pump. The inlet and outlet checks are assembled differently. Install the parts exactly as shown in Fig. 4.

Disassembly NOTE: Ball Check Repair Kit 245067 is available. Parts included in the kit are marked with a double dagger, for example (21). Use all the parts in the kit for the best results.

2. Install one cover (32) loosely, to prevent the ball checks from falling out. See page 14.
3. Turn the pump over and install the ball checks on the opposite side, exactly as shown.
1. Remove the fluid covers. See page 14.
2. Remove the inlet and outlet ball checks. Note that the orientation of the inlet check parts is different from the outlet check parts. See Fig. 4.
4. Reinstall the fluid covers. See page 14.
3. Clean all parts and inspect for wear or damage. Replace parts as needed.

10 ft-lb (13.6 Nm)

Show 25 more labels / short text on this page
Reassembly · 24 · 27 · 21 · Align · 24 · 26 · 25 · 23 · 21 · 27 · Inlet Ball Checks · Outlet Ball Checks · 22 · 25 · 26 · 27 · 21 · 21 · 23 · 27 · 24 · 24 · ti1032a · 16 309303
Page 17 of the Graco 233777 user manual — A 3
Page 17 · click to enlarge
Page 17

Diaphragm Repair

3. Thread an M8 hexnut (A) onto an M8 bolt. Screw the bolt into the shaft (5) until it bottoms out. Thread the nut down to the shaft to lock it.
4. Hold the nut with a wrench or vise to keep the shaft from turning. Unscrew the other diaphragm (6) by hand.

Adjustable wrench, or vise

1. Remove the fluid covers. See page 14.
1. Screw the new diaphragms (6*) into the shaft (5) handtight.

Wear gloves when removing the diaphragms to reduce the risk of cuts.

2. Replace the ball check seals (24*) with the new seals in the kit.
2. Unscrew one diaphragm (6) from the shaft (5) by hand. See Fig. 5.
3. Reinstall the fluid covers. See page 14.

10 ft-lb (13.6 Nm)

Use M8 bolt and nut to keep shaft from turning. 2

A 3

Show 13 more labels / short text on this page
Tools Required · M8 bolt · M8 hexnut · Reassembly · Align · 6* · 24* · *24 · *24 · 24* · *6 · ti1033a · 309303 17
Page 18 of the Graco 233777 user manual — Air Valve Repair
Page 18 · click to enlarge
Page 18

Air Valve Repair

5. Remove the retaining rings (11) and plug (9) from both sides, and slide the carriage (7) from the center housing (1). Remove the o-rings (8, 10) from the carriage and the plug.

3 mm allen wrench

6. Clean all parts and inspect for wear or damage. Replace parts as needed.

Retaining ring removal tool

Orient “POM” marking on air valve plate as shown in relation to fluid outlet arrow.

1. Remove the side cover (31) and felt dampener (29).
2. Remove the four screws (36), air valve cover (17), and gasket (16). See Fig. 7.
3. See Fig. 6. Note the orientation of the air valve plate (13) relative to the fluid outlet arrow, with “POM” marking up. Pull the plate out of the center housing (1). Remove the three o-rings (14, 15) and the two o–rings (43) from the plate. See Fig. 7.
4. Remove the air valve cup (12) from the center housing (1).

ti15226a Fig. 6

Show 8 more labels / short text on this page
Tools Required · Needlenose pliers · O-ring pick · Disassembly · “POM” marking · fluid outlet arrow · 13 · 18 309303
Page 19 of the Graco 233777 user manual — Air Valve Repair (continued)
Page 19 · click to enlarge
Page 19

Air Valve Repair (continued)

5. Lubricate the large o-ring (15 ) and the two small o-rings (14 ) and install them on the air valve plate (13 ). Align the point on the plate with the arrow on the center housing (1) as shown in Fig. 6. Install the plate in the housing.
1. Lubricate the o-rings (8 ) and install them on the carriage (7). Slide the carriage into the center housing (1) so the notch faces out, as shown in Fig. 7.
6. Install the gasket (16 ). Note the orientation.
2. Lubricate each o-ring (10 ) and install them on the plugs (9). Insert a plug in each side to secure the carriage (7). Install the retaining rings (11) to hold these parts in place.
7. Reinstall the air valve cover (17) and screws (36). Torque the screws to 28 in-lb (3.1 N m).
8. Replace the ball check seals (24 ) with the new seals in the kit.
3. Install the air valve cup (12 ) in the notch of the carriage (7) so the open side faces out.
4. Install two o–rings (43) in the counterbore of the air motor.
9. Reinstall the felt dampener (29) and side cover (31). See page 14.

2 10 9 11

28 in-lb (3.1 Nm)

Align. See Fig. 6.

14 15

Show 11 more labels / short text on this page
Reassembly · 2 Lubricate · 12 · 2 8 · 8 · 13 · 16 · 17 29 31 · 10 · ti1044d · 309303 19
Page 20 of the Graco 233777 user manual — CAUTION
Page 20 · click to enlarge
Page 20

Shaft Repair

7. If you could not remove one diaphragm from the shaft, place the shaft in a vise with soft jaws. Unscrew the remaining diaphragm (6) from the shaft (5) by hand.

Retaining ring removal tool

8. Clean all parts and inspect for wear or damage. Replace parts as needed.

Vise with soft jaws

1. Screw one diaphragm (6) into the shaft (5 ) handtight.
2. Lubricate the o–rings (45, 46) and install on the bearings (44). Install the bearings in the center housing (1) and secure with the retaining rings (47).
1. Remove the fluid covers. See page 14. Remove the side cover (31) and felt dampener (29).
3. Place the valve carriage (3) in the center housing (1). Grease the shaft (5 ) and slide it through the center housing and valve carriage.
2. Disassemble the air valve. See page 18.
3. Remove the diaphragms (6). See page 17.
4. Install the retaining rings (4 ) on the shaft (5 ).
4. Remove the retaining rings (4 ) from the shaft (5). See Fig. 8.
5. Screw the second diaphragm (6) into the shaft (5 ) handtight.
5. Slide the shaft (5) out of the center housing (1). Remove the valve carriage (3) from the housing.
6. Reassemble the air valve and carriage (see page 18), using the new o-rings (8 , 10 , 14 , 15 ) and gasket (16 ) included in the shaft repair kit.
6. Remove the retaining rings (47) and bearings (44). Remove the o–rings (45, 46) from the bearings.

CAUTION

7. Replace the ball check seals (24 ) with the new seals in the kit.

Do not grip the shaft with tools that can scratch or damage the shaft, such as wrenches or pliers.

8. Reinstall the fluid covers. See page 14.
Show 6 more labels / short text on this page
Tools Required · Needlenose pliers · O-ring pick · Disassembly · Reassembly · 20 309303
Page 21 of the Graco 233777 user manual — Shaft Repair (continued)
Page 21 · click to enlarge
Page 21

Shaft Repair (continued)

Graco 233777 — Shaft Repair (continued) diagram (page 21)
Fig. 1 · Shaft Repair (continued)

309303 21

Page 22 of the Graco 233777 user manual — Part No. 233500 Aluminum Pump, Series D, npt threads
Page 22 · click to enlarge
Page 22

Parts

Part No. 233500 Aluminum Pump, Series D, npt threads

Part No. 233501 Stainless Steel Pump, Series C, npt threads (Shown)

Part No. 233776 Aluminum Pump, Series C, BSPP threads

Part No. 233777 Stainless Steel Pump, Series C, BSPP threads

Graco 233777 — Part No. 233500 Aluminum Pump, Series D, npt threads diagram (page 22)
Fig. 2 · Part No. 233500 Aluminum Pump, Series D, npt threads

ti1036F · 22 309303

Page 23 of the Graco 233777 user manual — Parts
Page 23 · click to enlarge
Page 23

Parts

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

1 15J732 HOUSING, center; for Part No. 233500; aluminum 1 198894 HOUSING, center; for Part No. 233501; stainless steel 1 198892 HOUSING, center; for Part No. 233776; aluminum 1 197679 HOUSING, center; for Part No. 233777; stainless steel 1 3 197645 CARRIAGE, valve 1 4 197646 RING, retaining, shaft 2 5 n/a SHAFT, diaphragm 1 6* 197648 DIAPHRAGM; PTFE composite 2 7 197649 CARRIAGE 1 8 197650 O-RING, carriage 2 9 197651 PLUG, carriage 2 10 197652 O-RING, plug 2 11 197653 RING, retaining, carriage 2 12 197654 CUP, valve, air 1 13 197655 PLATE, valve, air 1 14 197656 O-RING, valve, air 2 15 197657 O-RING, valve, air 1 16 197658 GASKET, valve, air 1 17 197659 COVER, valve, air 1 18 197660 VALVE, safety, air 1 19 197661 PLATE, dampener; neoprene 1 20 197662 DAMPENER; steel 1 21 197663 BALL; acetal 4 22 197664 SEAL, valve, outlet; acetal 2 23 197665 SEAT, valve, outlet; stainless steel 2 24* 197666 SEAL, ball check; nylon 4 25 197667 O-RING, valve, inlet; fluoroelastomer 2 26 197668 SEAT, valve, inlet; stainless steel 2 27 197669 GUIDE, ball; acetal 4 28 197670 DAMPENER, felt, air inlet side 1 29 197671 DAMPENER, felt, side 1 30 16A659 COVER, air inlet side 1 31 16A661 COVER, side 1

32 197674 COVER, housing; for Part Nos. 233500 and 233776; aluminum 2 197680 COVER, housing; for Part Nos. 233501 and 233777; stainless steel 2 33 198832 FITTING, air inlet; for Part Nos. 233500 and 233501 1 198831 FITTING, air inlet; for Part Nos. 233776 and 233777 1 35 116343 SCREW, grounding; M5 x 10 1 36 116474 SCREW, cap, socket-hd; M4 x 20 4 37 116475 SCREW, cap, socket-hd; M4 x 12 2 38 117367 SCREW, cap, socket-hd; M8 x 18; for Part Nos. 233500 and 233776 12 15D128 SCREW, same as above; for Part Nos. 233501 and 233777 12 39 116595 SCREW, button-hd; M4 x 12 2 40 188621 LABEL, warning 1 43 157628 O–RING 2 44 n/a BEARING 2 45 n/a O–RING, nitrile 2 46 n/a O–RING, nitrile 2 47 n/a RING, retaining 2

* These parts are only available by purchasing Dia- phragm Repair Kit 245065.

These parts are only available by purchasing Air Valve Repair Kit 245066.

These parts are only available by purchasing Ball Check Repair Kit 245067.

These parts are only available by purchasing Shaft

and Bearing Repair Kit 24A155.

Replacement Danger and Warning labels, tags and

cards are available at no cost.

This part available in 10–pack kit 15D564 or in Ball

Check Repair kit 245067

309303 23

Page 24 of the Graco 233777 user manual — AIR CONSUMPTION
Page 24 · click to enlarge
Page 24

Technical Data

Graco 233777 — Technical Data diagram (page 24)
Fig. 3 · Technical Data

Air pressure operating range 12 to 115 psi (.08 to 0.8 MPa, 0.8 to 8.0 bar)

50 to 176 C (10 to 80 C)

Maximum suction lift 16 ft (4.8 m) dry; 22 ft (6.5 m) wet

Weight Part Nos. 233500, 2337769 lb (4 kg) Part Nos. 233501, 233777: 14 lb (6.4 kg)

Wetted parts Part Nos. 233500, 233776: Aluminum, Stainless Steel, Acetal, Nylon, PTFE,

fluoroelastomer Part Nos. 233501, 233777Stainless Steel, Acetal, Nylon, PTFE, fluoroelastomer

Sound Pressure Levels in dB(A)*

Sound Power Levels in dB(A)* (tested in accordance with ISO 3744)

(measured at 1 m from unit)

Input Air Pressures Sound Pressure

Input Air Pressures Sound Power

40 psi (0.28 MPa, 2.8 bar) 69.1

40 psi (0.28 MPa, 2.8 bar) 80.8

60 psi (0.42 MPa, 4.2 bar) 72.1

60 psi (0.42 MPa, 4.2 bar) 83.7

Performance Chart

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

To find Pump Air Consumption (l/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
2. Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A 115 psi (0.8 MPa, 8 bar) air pressure B 90 psi (0.6 MPa, 6 bar) air pressure C 60 psi (0.4 MPa, 4 bar) air pressure D 30 psi (0.2 MPa, 2 bar) air pressure

Test Fluid: No. 10 Weight Oil

scfm l/min

24 47 71 cycles per minute

94 141 165 188

Graco 233777 — Test Fluid: No. 10 Weight Oil diagram (page 24)
Fig. 4 · Test Fluid: No. 10 Weight Oil
Graco 233777 — Test Fluid: No. 10 Weight Oil diagram (page 24)
Fig. 5 · Test Fluid: No. 10 Weight Oil

0.8, 8.0

AIR CONSUMPTION

FLUID PRESSURE

0.7, 7.0

0.4, 4.0

0.3, 3.0

0.14, 1.4

0 1 2 3 4 5 6 7 8

gpm l/min 22.8 7.6 11.4

0 1 2 3 4 5 6 7 8

gpm l/min 22.8 7.6 11.4

3.8 15.2 19.0 26.6

3.8 15.2 19.0 26.6

Show 8 more labels / short text on this page
Fluid Outlet Pressure · Air Consumption · psi MPa, bar · cycles per minute · 24 47 71 · 141 165 188 · 196 224 · 24 309303
Page 25 of the Graco 233777 user manual — TI3265A
Page 25 · click to enlarge
Page 25

Dimensions

BOTTOM VIEW

4.53 in. (115 mm)

3/8 npt or 3/8 BSPP Fluid Outlet

Two 0.35 in. (9 mm) diameter holes, for mounting pump

1/4 npt or 1/4 BSPP Air Inlet

3/4 npt or M26 x 1.5 Fluid Inlet

4.1 in. (104 mm)

SIDE VIEW

SIDE VIEW

SST

4.88 in. (124 mm)

9.1 in. (231.5 mm)

8.2 in. (208 mm)

TI3265A

Aluminum · ti1037a · 309303 25

Page 26 of the Graco 233777 user manual — Graco Information
Page 26 · click to enlarge
Page 26

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor, or call one of these numbers

to identify the distributor closest to you:

1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM 309303

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 2001, Graco Inc. is registered to ISO 9001

www.graco.com

Revised 02/2011 · 26 309303

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump will not run.Closed air line valve.Open valve. p.12
Pump will not run.Inadequate air supply, or clogged/ restricted air line.Increase air supply. Do not exceed maximum air inlet pressure. p.12
Pump will not run.Open or clear air line. p.12
Pump will not run.Clean air filter. p.12
Pump will not run.Clogged pump, fluid line, or spray gun.Clear, service. Flush regularly. Do not allow fluid to set up in the pump and lines. p.12
Pump will not run.Stuck or damaged pump air valve.Disassemble and clean air valve. Replace worn parts. See page 18. Use filtered air. p.12
Pump will not run.Ruptured diaphragm.Replace diaphragms. See page 17. p.12
Pump will not run.Air valve plate installed incorrectly.Align plate with center housing. See page 19. p.12
Pump runs sluggishly.Worn or damaged carriage o-rings.Service air valve. See page 18. p.13
Pump runs erratically.Clogged suction line or inlet strainer.Clear. p.13
Pump runs erratically.Sticking or leaking ball check valves.Disassemble and clean ball checks. Replace worn parts. See page 16. p.13
Pump runs too fast.Exhausted fluid supply.Refill fluid supply and prime pump. p.13
Pump cycles at stall or fails to hold pressure at stall.Worn ball check valves.Disassemble and clean ball checks. Replace worn parts. See page 16. p.13
Audible air leak.Worn air valve cup or plate.Service air valve. See page 18. p.13
Air exhausting from the mounting holes.Fluid covers are installed incorrectly.Align mounting holes in fluid covers with holes in center housing. See page 14. p.13
Fluid in the exhaust air.Ruptured diaphragm.Replace diaphragms. See page 17. p.13
Air bubbles in fluid.Loose suction line.Tighten. Use a compatible liquid thread sealant on connections. p.13
Air bubbles in fluid.Ruptured diaphragm.Replace diaphragms. See page 17. p.13
Poor finish or irregular spray pat- tern.Incorrect fluid or air pressure at gun.See gun manual; read fluid manufacturer’s recommendations. Use fluid regulator. p.13
Poor finish or irregular spray pat- tern.Fluid is too thin or too thick.Adjust fluid viscosity; read fluid manufacturer’s recommendations. p.13
Poor finish or irregular spray pat- tern.Dirty, worn, or damaged spray gun.Service gun. p.13
Poor finish or irregular spray pat- tern.Fluid is settling out.Use agitator. Order Part No. 245081 Agitator Kit. p.13

Ask about the Graco 233777

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 233777

Be the first to ask — other owners or our team will answer.

Original document

Graco 233777 manual PDF

26 pages·440 KB·Heat Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…