Page 1 of the Graco 224434 user manual — INSTRUCTIONS
Page 1 · click to enlarge
Page 1

INSTRUCTIONS-PARTS LIST

Rev. V

This manual contains important warnings and information. READ AND KEEP FOR REFERENCE.

quality counts.

INSTRUCTIONS

45:1 Ratio King Pump

4050 psi (28 MPa, 279 bar) Maximum Working Pressure

90 psi (0.6 MPa, 6.2 bar) Maximum Air Input Pressure

Model 224434, Series A Stubby Size, with Standard Air Motor and Severe-Duty Displacement Pump*, with leather packings

*Severe-Duty Displacement Pumps have an abrasion and corrosion-resistant displacement rod and sleeve. Refer to the Technical Data in the separate displace- ment pump manual 307728 for Wetted Parts informa- tion.

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 COPYRIGHT 1997, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001

Parts · First choice when ·

Page 4 of the Graco 224434 user manual — Flushing Safety
Page 4 · click to enlarge
Page 4

Installation

Grounding

All solvent pails used when flushing, according to local code. Use only metal pails, which are conduc- tive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which inter- rupts grounding continuity.

FIRE AND EXPLOSION HAZARD Before operating, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 3.

To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the gun firmly to the side of a grounded metal pail, then trigger the gun.

W

To reduce the risk of static sparking, ground the pump and all other components used or located in the spray/ dispensing area. Check your local electrical code for detailed instructions for your area and type of equip- ment and be sure to ground all of these components.

X Y

Z

Pump: loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm2) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. See Fig. 1. Connect the other end of the wire to a true earth ground. Order Part No. 237569 Ground Wire and Clamp.

Flushing Safety

Air and Fluid Hoses: Use only electrically conduc- tive hoses with a maximum of 500 feet (150 m) combined hose length to ensure grounding continu- ity.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

Air Compressorfollow the air compressor manufacturer’s recommendations

Before flushing, be sure the entire system and flushing pails are properly grounded. Refer to Grounding at left. Follow the Pressure Relief Procedure on page 7, and remove the spray tip/nozzle from the gun/dis- pensing valve. Always use the lowest possible fluid pressure, and maintain firm metal-to-metal contact between the gun/dispensing valve and the pail during flushing to reduce the risk of fluid injection injury, static sparking, and splashing.

Spray gun/dispensing valve: obtain grounding through connection to a properly grounded fluid hose and pump.

Fluid supply container: according to local code.

Object being sprayed: according to local code.

· 307013

Page 5 of the Graco 224434 user manual — M
Page 5 · click to enlarge
Page 5

Installation

Typical Installation

Y

H

D

E

N

P (PLUG WHEN EXHAUSTING THROUGH MUFFLER)

R

F G

S

J

K

A B C D E F G H J K L M N P R S Y

Pump Pump Runaway Valve Air Line Lubricator Bleed-Type Master Air Valve (required, for pump) Pump Air Regulator Air Line Filter Bleed-Type Master Air Valve (for accessories) Air Supply Hose Fluid Drain Valve (required) Fluid Supply Hose Spray Gun Fluid Suction Hose Exhaust Port for Muffler (1–1/4” npt) 16 Exhaust Holes Wall Bracket Packing Nut/Wet-Cup Ground Wire (required)

M

Key · · 307013

Page 6 of the Graco 224434 user manual — Air Motor Exhaust
Page 6 · click to enlarge
Page 6

Installation

Use an electrically conductive 3/4 in. ID (minimum) air hose (H) to supply air to the pump.

Air Line Accessories

Install the following accessories in the order shown in the Typical Installation, using adapters as necessary:

An air line lubricator (C) provides automatic air motor lubrication.

The Typical Installation shown on page 5 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.

A bleed-type master air valve (D) is required in your system to relieve air trapped between it and the motor when the valve is closed (see the WARN- ING at left). Be sure the bleed valve is easily ac- cessible from the pump, and is located downstream from the air regulator.

System Accessories

Refer to the Typical Installation on page 5.

A pump runaway valve (B) senses when the pump is running too fast and automatically shuts off the air to the motor. A pump which runs too fast can be seriously damaged. Install closest to the pump air inlet.

Two accessories are required in your system: a bleed-type master air valve (D) and a fluid drain valve (J). These accessories help reduce the risk of serious injury including splashing in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.

An air regulator (E) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the bleed-type master air valve.

The bleed-type master air valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump.

An air line filter (F) removes harmful dirt and moisture from the compressed air supply.

The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.

A second bleed-type air valve (G) isolates the air line accessories for servicing. Locate upstream from all other air line accessories.

Fluid Line Accessories

Mounting Accessories

Install the following accessories in the order shown in the Typical Installation, using adapters as necessary:

Mount the pump (A) to suit the type of installation planned. The pump dimensions and mounting hole layout are shown on page 14. Use 3/8 in. bolts, lock- washers, and nuts to attach the pump firmly to the mounting.

A fluid drain valve (J) is required in your system to relieve fluid pressure in the hose and gun (see the WARNING at left).

Air and Fluid Hoses

A spray gun (L) dispenses the fluid. The gun shown in the Typical Installation is an airless spray gun.

Be sure all air and fluid hoses are properly sized and pressure-rated for your system. Use only electrically conductive air and fluid hoses. Fluid hoses must have spring guards on both ends.

Air Motor Exhaust

Connect a electrically conductive fluid hose (H) to the pump’s 1” npt(f) fluid outlet, using a suitable adapter.

To route the air motor exhaust outside, remove the exhaust port plug and connect the hose to the 1–1/4 npt(f) exhaust port (N). Plug the 16 exhaust holes in the base of the motor with 1/4 in. size x 1/2 in. long self-tapping screws.

Connect a fluid suction hose and tube (M) to the pump’s 1–1/2” npt(f) fluid intake.

307013

Page 7 of the Graco 224434 user manual — Pressure Relief Procedure
Page 7 · click to enlarge
Page 7

Operation

Pressure Relief Procedure

1. Lock the spray gun/dispensing valve trigger safety.
2. Shut off the air to the pump.

INJECTION HAZARD Fluid under high pressure can be in- jected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

3. Close the bleed-type master air valve (required in your system).
4. Unlock the trigger safety.
5. Hold a metal part of the gun/valve firmly to the side of a grounded metal pail, and trigger the gun/valve to relieve pressure.
6. Lock the trigger safety.

are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean any part of the system.

7. Open the drain valve (required in your system), having a container ready to catch the drainage.
8. Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip/nozzle is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip/nozzle or hose.

307013

Page 8 of the Graco 224434 user manual — Check Valve Adjustment
Page 8 · click to enlarge
Page 8

Operation

In a direct supply system, with the pump and lines primed and with adequate air pressure and volume supplied, the pump will start and stop as the spray gun is opened and closed. In a circulating system, the pump will run continuously and will speed up or slow down as supply demands until the air supply is shut off.

Moving parts can pinch or amputate your fingers or other body parts. When air is supplied to the motor, the air motor piston (located behind the air motor shield) moves. Therefore, never operate the pump with the ar motor shield removed.

Use an adequately sized air regulator (E) to control the pump speed and the fluid pressure. Always use the lowest air pressure necessary to get the desired results. Higher pressures waste fluid and cause pre- mature wear of the pump packings and spray tip.

Flush the Pump Before Using

The pump is tested with lightweight motor oil, which is left in to protect the pump parts. If the fluid you are pumping may be contaminated by the oil, flush out the oil with a compatible solvent before using the pump. If the pump is being used to supply a circulating system, allow the solvent to circulate until the pump is thor- oughly flushed.

Keep the packing nut/wet-cup (S) half filled with Graco Throat Seal Liquid (TSL) or compatible solvent, to help prolong the packing life. Adjust the packing nut weekly with the wrench (supplied) so it is just tight enough to prevent leakage; do not overtighten. Always relieve the pressure before adjusting the packing nut.

Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. A pump runaway valve (B), which shuts off the air supply to the pump if the pump accelerates beyond the pre-set speed, is available. See the Typical Installation on page 5. If your pump accelerates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, refill the container and prime the pump and the lines with fluid, or flush and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system.

For your safety, read the warning section, FIRE AND EXPLOSION HAZARD on page 3 before flushing, and follow all instructions given there.

Starting and Adjusting the Pump

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

See the Typical Installation on page 5. Be sure the air regulator (E) and bleed-type master air valve (D) are closed. Do not install the spray tip yet.

Shutdown and Care of the Pump

For overnight shutdown, relieve the pressure. Always stop the pump at the bottom of the stroke to prevent the fluid from drying on the exposed displacement rod and damaging the throat packings.

Connect a suction hose (M) to the pump’s fluid inlet. Hold a metal part of the spray gun (L) firmly to the side of a grounded metal pail and hold the trigger open. Then open the pump’s bleed-type master air valve (D). Now slowly open the air regulator until the pump starts, about 20 psi (140 kPa, 1.4 bar).

Always flush the pump before the fluid dries on the displacement rod. Never leave water or water-based fluid in the pump overnight. First, flush with water or a compatible solvent, then with mineral spirits. Relieve the pressure, but leave the mineral spirits in the pump to protect the parts from corrosion.

Cycle the pump slowly until all the air is pushed out, and fluid is flowing from the gun in a steady stream. Release the spray gun trigger and lock the trigger safety. The pump should stall against pressure when the trigger is released.

Check Valve Adjustment

Relieve the pressure, then install the spray tip in the gun.

Refer to the separate displacement pump manual 307728 for check valve adjustment information.

307013

Page 9 of the Graco 224434 user manual — Troubleshooting
Page 9 · click to enlarge
Page 9

Troubleshooting

Graco 224434 — Troubleshooting diagram (page 9)
Fig. 1 · Troubleshooting

Before servicing this equipment always make sure to Relieve the Pressure.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

ProblemCauseSolution Pump fails to operateRestricted line or inadequate air supplyClear; increase air supply. Obstructed fluid hose, gun, or dispensing valveOpen, clear.* Exhausted fluid supplyRefill; Purge all air from pump and fluid lines. Fluid dried on displacement rodClean; always stop pump at bottom of stroke; keep wet-cup 1/2 filled with compatible solvent. Damaged air motorService air motor (see manual 306968). Pump operates but output low on both strokesRestricted line or inadequate air supplyClear; increase air supply. Obstructed fluid hose, gun, or dispensing valveOpen, clear.* Exhausted fluid supplyRefill; purge all air from pump and fluid lines. Air in displacement pump and hoseReprime. Check valves need adjustmentAdjust (see manual 307728). Packing nut too tight or too looseAdjust (see manual 307728). Worn throat packingsReplace (see manual 307728). Pump operates but output low on down strokeHeld open or worn intake valveClear; service (see manual 307728). Pump operates but output low on up strokeHeld open or worn fluid piston valve or packingsClear, service (see manual 307728). Erratic or accelerated operationExhausted fluid supplyRefill; purge all air from pump and fluid lines. Packing nut too tightAdjust (see manual 307728). Check valves need adjustmentAdjust (see manual 307728). Held open or worn intake valveClear; service (see manual 307728). Held open or worn fluid piston valve or packingsClear; service (see manual 307728).

* To determine if the fluid hose or gun/valve is obstructed, relieve the pressure. Disconnect the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump (about 20–40 psi [140–280 kPa, 1.4–2.8 bar]). If the pump starts when the air is turned on, the obstruction is in the fluid hose gun/valve.

307013

Page 10 of the Graco 224434 user manual — Disconnecting the Displacement Pump
Page 10 · click to enlarge
Page 10

Service

Reconnecting the Displacement Pump

1. Orient the pump’s fluid outlet (A) to the air motor’s air inlet (B) as was noted in step 2 under Disconnecting the Displacement Pump . Position the displacement pump (2) on the tie rods (31).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7.

Disconnecting the Displacement Pump

2. Place the coupling nut (32) on the connecting rod (T). Insert the couplers (33) into the coupling nut from the top. Screw the coupling nut (32) onto the air motor piston rod. Screw the locknuts (26) onto the tie rods (31) loosely.
1. Flush the pump, if possible. Stop the pump at the bottom of its stroke. Relieve the pressure.
2. Disconnect the air and fluid hoses. Remove the pump from its mounting. Note the relative position of the pump’s fluid outlet (A) to the air motor’s air inlet (B). See Fig. 2.
3. Mount the pump and reconnect all hoses. Reconnect the ground wire if it was disconnected during repair.
3. Screw the coupling nut (32) off of the air motor piston rod. Be careful not to lose the two couplers (33) as you lower the nut. Unscrew the tie rod locknuts (26) from the tie rods (31). Carefully pull the displacement pump (2) away from the air motor (1).
4. Tighten the tie rod locknuts (109) evenly, and torque to 40–50 ft-lb (54–68 N m).
5. Tighten the packing nut/wet-cup (S) with the wrench (28) supplied, so it is just snug - no tighter. Fill the wet-cup 1/2 full with Graco Throat Seal Liquid (TSL) or compatible solvent. Start the pump and run it slowly at about 20 psi (140 kPa, 1.4 bar) air pressure, to check that it is operating properly.
4. Refer to the instruction manual 307728 (supplied) for displacement pump service instructions.
5. Refer to instruction manual 306968 (supplied) for air motor service instructions.
Page 11 of the Graco 224434 user manual — T
Page 11 · click to enlarge
Page 11

Service

Torque to 40–50 ft-lb (54–68 Nm)

Torque to 145–155 ft-lb (195–210 Nm)

T

S

Model 224434 shown ·

Page 12 of the Graco 224434 user manual — Parts
Page 12 · click to enlarge
Page 12

Parts

Model 224434, Series A Stubby Size, with Standard Air Motor and Severe-Duty Displacement Pump with leather packings

Ref. No. Part No. Description Qty.

1 207647 AIR MOTOR See Manual 306968 for parts 1 2 224435 DISPLACEMENT PUMP ASSY See Manual 307728 for parts 1 26 101712 NUT, lock; 5/8–11 3 28 102176 WRENCH 1 31 167911 ROD. tie; 7” (178 mm), shoulder-to-shoulder 3 32 186925 NUT, coupling 1 33 184129 COUPLING 1

Includes items 1–33 · · 307013

Page 13 of the Graco 224434 user manual — Notes
Page 13 · click to enlarge
Page 13

Notes

307013

Page 14 of the Graco 224434 user manual — 5/8–11 UNC (3) FOR PUMP ATTACHMENT
Page 14 · click to enlarge
Page 14

Dimensions Mounting Hole

Layout

See 306968 for Air Motor Dimensional Drawing.

3.712” (94 mm)

3.464” (88 mm)

4.0” (102 mm)

4.0” (102 mm)

3/4 npt(f) AIR INLET

2.0” (51 mm)

3.712” (94 mm)

1.875” (48 mm) FOR OUTLET RISER TUBE

0.44” (11.1 mm)

5/8–11 UNC (3) FOR PUMP ATTACHMENT

DIA. (4)

1” npt(f) FLUID OUTLET

1–1/2” npt(f) FLUID INTAKE

WEIGHT110 lb (50 kg)

Pump A B Model

224434, 42.5 in. 21 in. (1079.5 mm) (533.4 mm)

· · 307013

Page 15 of the Graco 224434 user manual — AIR CONSUMPTION
Page 15 · click to enlarge
Page 15

Technical Data

Maximum fluid working pressure 4050 psi (28 MPa, 279 bar)

Maximum air pressure (see cover) 90 psi (0.6 MPa, 6.2 bar)

Pump cycles per 1 gallon (3.8 liters) 16

Fluid flow at 50 cpm 3.3 gpm (12 liter/min)

Wetted parts See displacement pump manual 307728

Sound Pressure Levels (dBa) (measured at 1 meter from unit)

Input Air Pressures at 15 cycles per minute

0.28 MPa, 2.8 bar (40 psi)

0.48 MPa, 4.8 bar (70 psi)

0.6 MPa, 6.2 bar (90 psi)

King 78.8 82.7 90.5

Sound Power Levels (dBa) (tested in accordance with ISO 9614–2)

Input Air Pressures at 15 cycles per minute

0.28 MPa, 2.8 bar (40 psi)

0.48 MPa, 4.8 bar (70 psi)

0.6 MPa, 6.2 bar (90 psi)

King 86.5 88.8 97.7

Performance Chart

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

To find Pump Air Consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
2. Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A 0.6 MPa, 6.2 bar (90 psi) air pressure B 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pressure

Test Fluid: No. 10 Weight Oil

32 48 64 psi MPa, bar

scfm m/min

31.5, 315

AIR CONSUMPTION

FLUID PRESSURE

10.5, 105

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Show 18 more labels / short text on this page
Category Data · Air Motor · Air Motor · Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · 32 48 64 · · · · · 21, 210 · · · · · 307013
Page 16 of the Graco 224434 user manual — Graco Phone Number
Page 16 · click to enlarge
Page 16

The Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accor- dance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Phone Number

TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:

1–800–367–4023 Toll Free.

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales OfficesMinneapolis, Detroit Foreign Offices: Belgium, Korea, Hong Kong, Japan

www.graco.com GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 PRINTED IN U.S.A. 307013 August 1969, Revised May 2000

307013

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump fails to operateRestricted line or inadequate air supplyClear; increase air supply. p.9
Pump fails to operateObstructed fluid hose, gun, or dispensing valveOpen, clear.* p.9
Pump fails to operateExhausted fluid supplyRefill; Purge all air from pump and fluid lines. p.9
Pump fails to operateFluid dried on displacement rodClean; always stop pump at bottom of stroke; keep wet-cup 1/2 filled with com- patible solvent. p.9
Pump fails to operateDamaged air motorService air motor (see manual 306968). p.9
Pump operates but output low on both strokesRestricted line or inadequate air supplyClear; increase air supply. p.9
Pump operates but output low on both strokesObstructed fluid hose, gun, or dispensing valveOpen, clear.* p.9
Pump operates but output low on both strokesExhausted fluid supplyRefill; purge all air from pump and fluid lines. p.9
Pump operates but output low on both strokesAir in displacement pump and hoseReprime. p.9
Pump operates but output low on both strokesCheck valves need adjustmentAdjust (see manual 307728). p.9
Pump operates but output low on both strokesPacking nut too tight or too looseAdjust (see manual 307728). p.9
Pump operates but output low on both strokesWorn throat packingsReplace (see manual 307728). p.9
Pump operates but output low on down strokeHeld open or worn intake valveClear; service (see manual 307728). p.9
Pump operates but output low on up strokeHeld open or worn fluid piston valve or packingsClear, service (see manual 307728). p.9
Erratic or accelerated operationExhausted fluid supplyRefill; purge all air from pump and fluid lines. p.9
Erratic or accelerated operationPacking nut too tightAdjust (see manual 307728). p.9
Erratic or accelerated operationCheck valves need adjustmentAdjust (see manual 307728). p.9
Erratic or accelerated operationHeld open or worn intake valveClear; service (see manual 307728). p.9
Erratic or accelerated operationHeld open or worn fluid piston valve or packingsClear; service (see manual 307728). p.9

Ask about the Graco 224434

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 224434

Be the first to ask — other owners or our team will answer.

Original document

Graco 224434 manual PDF

16 pages·307 KB·Marine Sanitation System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…