S
R
B
U
K
J
H
P
N
M D
G
F
E
·

WARNING
To reduce risk of pressure control malfunction:
EXPLOSION HAZARD Motor and drive housing are very hot during operation and could burn skin if touched. Flammable materials spilled on hot, bare motor could cause fire or explosion. Have motor shield in place during operation to reduce risk of burns, fire or explosion.
Use needle nose pliers to disconnect a wire. Never pull on wire, pull on connector.
Mate wire connectors properly. Center flat blade of insulated male connector in female connector.
Route wires carefully to avoid interference with other connections of pressure control. Do not pinch wires between cover and control box.
Do not run sprayer dry for more than 30 seconds to avoid damaging pump packings.
Phillips screwdriver Small flat blade
1/4 in. hex key wrench 3/16 in. hex key wrench 5/8 in. socket wrench 3/8 in. open end wrench 1/2 in. open end wrench 3/4 in. open end wrench 7/8 in. open end wrench High quality motor oil Bearing grease
screwdriver Needle nose pliers Plastic mallet or 20 oz
(max) hammer 12 in. adjustable wrench Adjustable, open-end
WARNING
INJECTION HAZARD System pressure must be manually relieved to prevent system from starting or spraying accidentally. Fluid under high pressure can be injected through skin and cause serious injury. To reduce risk of injury from injec- tion, splashing fluid, or moving parts, follow Pres- sure Relief Procedure whenever you:
are instructed to relieve pressure, stop spraying, check or service any system equipment, or install or clean spray tip.
ELECTRIC SHOCK HAZARD To reduce risk of serious injury, including electric shock, do not touch moving or electrical parts with fingers or tools while testing repair. Shut off and unplug sprayer when inspection is complete. Install all covers, gaskets, screws and washers before operating sprayer.
1. Lock gun safety latch. 2. Turn ON/OFF switch to OFF. 3. Unplug power supply cord. 4. Unlock gun safety latch. Hold metal part of gun firmly to grounded metal pail. Trigger gun to relieve pressure. 5. Lock gun safety latch. 6. Open pressure drain valve. Leave pressure drain valve open until ready to spray again. If suspected that spray tip or hose is completely clogged, or that pressure has not been fully relieved after following steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Now clear tip or hose obstruction.
wrench Torque wrench ·

WARNING
Grounding Plug Grounded Outlets
Improper installation or alteration of grounding plug results in risk of electric shock, fire or explosion that could cause serious injury or death.





Armature, Brushes, and Motor Wiring Open Circuit Test (Continuity)
Electric Shock Hazard; page 3.
To check armature, motor winding and brush electrical continuity:
Quickly turn motor fan by hand. If no electrical shorts, motor coasts two or three revolutions before complete stop. If motor does not spin freely, armature is shorted. Replace motor; page 16.
Fig. 3 G
(Continued on page 10)
Brushes wear differently on each side of motor, check both sides. Brush Repair Kit 220853 is available. Spring clip, 110816, may be purchased separately.

J
G
E
H
B C
H
NOTE SPRING COIL DIRECTION
G
E
a. Remove pump connecting rod pin.
b. With sprayer OFF, turn pressure control knob fully counterclockwise to minimum pressure. Plug in sprayer.
c. Turn sprayer ON. Slowly increase pressure until motor is at full speed.
When installing brushes, follow all steps carefully to avoid damaging parts.
Do not run sprayer dry for more than 30 seconds while checking brushes to avoid damaging displace- ment pump packings.
a. Operate sprayer 1 hour with no load.
b. Install connecting rod pin.
· ·


8052B Fig. 7

Installation 1. Fig. 7. Install motor control board (104) with four screws (102).
Lead (E) to transducer.
Lead (D) to potentiometer.
Filter board (8).
Six motor leads: two yellow, two violet, black (+) and red (–).
Six motor leads: two yellow, two violet, black (+) and red (–).
Filter board (8).
Lead (D) from potentiometer.
Lead (E) from transducer.

INDICATION ACTION
No Display Sprayer stops. Power is not applied. Sprayer may be pressurized.
Loss of power Check power source
Sprayer is pressurized. Power is applied. (Pressure varies with tip size and pres- sure control setting.)
Sprayer stops. Power is applied. Pressure greater than 4500 psi (310 bar, 31 MPa). Replace pressure control board
Sprayer stops. Power is applied. Pressure transducer faulty Replace
Sprayer stops. Power is applied. Line voltage too high Set voltage to: 230 VAC for models 232144, 145, 154 110 VAC for models 232148, 158 100 VAC for models 232156, 157
Sprayer stops. Power is applied. Locked rotor. Motor can not turn
Sprayer stops. Power is applied. Pressure less than 200 psi (14 bar, 1.4 MPa) Increase pressure
Pressure Adjust Potentiometer
Removal
Installation
Normal operation Spray · Repair or replace ·

Replacement
Do not use bearing housing screws (25) to align or seat bearing housing; this may cause bearing and drive housing misalignment and result in premature bearing wear.
Pack with bearing grease
Torque to 175 in-lb (19 Nm)


Do not drop gear cluster (51) when removing drive housing (67). Gear cluster may stay engaged in motor front end bell or drive housing.
Do not lose thrust balls (90) or drop thrust balls between gears. If thrust balls are caught between gears and not removed, serious damage will occur to drive housing. If thrust balls are not in place at each end of gear cluster, bearings will wear prematurely.

2 Torque to 90–100 in-lb (10.2–11.3 Nm)


Do not drop gear cluster (51) when removing drive housing (67). Gear cluster may stay engaged in motor front end bell or drive housing.
Do not lose thrust balls (90) or drop thrust balls between gears. If thrust balls are caught between gears and not removed, serious damage will occur to drive housing. If thrust balls are not in place at each end of gear cluster, bearings will wear prematurely.

Always pull the motor leads one at a time to avoid loosening the terminals, which could result in a bad connection and poor sprayer performance.

2 Torque to 90–100 in-lb (10.2–11.3 Nm)

See manual 308798 for pump repair instructions.
If pin works loose, parts could break off due to force of pumping action. Parts could project through the air and result in serious injury or prop- erty damage.
Fig. 15. Screw jam nut down onto pump until stops. Screw pump up into bearing housing until it is stopped by jam nut. Back off pump and jam nut to align pump outlet to back. Tighten jam nut by hand, then tap 1/8 to 1/4 turn with a 20 oz (maximum) hammer to approxi- mately 75 5 ft–lb (102 Nm).
If the pump locknut loosens during operation, the threads of the bearing housing will be damaged.
Fig. 16. Fill packing nut with Graco TSL, through one of the slits, until fluid flows onto the top of seal.
1.5 in.


Ultra MAX 795 and 1095 Hi-boy Sprayers Model 232144, Series A Model 232154, Series A Model 232148, Series A Model 232158, Series A Model 232156, Series A

Ultra MAX 795 and 1095 Hi-boy Sprayers Model 232144, Series A; Model 232154, Series A Model 232148, Series A; Model 232156, Series A; Model 232158, Series A
REF NO. PART NO. DESCRIPTION QTY
10 110996 NUT, heavy hex, 5/16–18 unc–2a 4 14 101242 RING, retaining 2 16 100644 SCREW, socket hd, 1/4–20 x 0.75 in. 4 19 104811 HUBCAP 2 20 105510 LOCKWASHER, spring, 1/4 in. 6 21 106062 WHEEL, semi–pneumatic 2 22 240523 BEARING HOUSING 1 23 106115 LOCKWASHER, spring, 3/8 in. 4 24 114406 SCREW, filh, no. 8–32 x1 in. 4 25 107210 CAPSCREW, sch, 3/8–16 x 1–1/2 in. 4 26 107218 CAPSCREW, sch, 1/4–20 x 2.75 in. 2 30 111801 SCREW, serrated flange, hex hd, 7 5/16–18 x 1/2” 32 112746 NUT, hex 2 33 108691 PLUG, tubing 2 34 108865 SCREW, pan head, no. 8 x 3/8 in. 6 35 109032 SCREW, pnhd, 10–32 x 1/4 in. 4 37 110243 RING, retaining 2 38 192691 CLIP, spring 1 39 192641 TUBE, intake 1 40 162453 NIPPLE, 1/4 npt(m) x 1/4 npsm 2 41 LABEL, DANGER 2 187791 English 2 189702 Japanese 2 47 192723 NUT, hex 1 48 112827 BUTTON, snap 2 49 COVER, housing 1 188154 Ultra Max 795 1 179899 Ultra Max 1095 1 51 179961 GEAR REDUCER 1 52 183350 WASHER 2 53 181072 STRAINER 1 54 SHIELD, motor 1 includes 41 240317 Ultra Max 795 1 240313 Ultra Max 1095 1 61 192719 HANGER, pail 1 62 192027 SLEEVE 2 63 218034 CONNECTING ROD 1 64 239923 DISPLACEMENT PUMP 1 see manual 308798 for parts 65 206994 THROAT SEAL LIQUID, 8 OZ 1
66 176818 PIN, straight, hdls, 1 0.3125 in. dia x 1.023 in. 67 DRIVE HOUSING 1 includes 67a and 67b 239931 Ultra Max 795, Model 232144, 148 1 239929 Ultra Max 1095, 1 Model 232154, 158 218032 Ultra Max 1095, Model 232156 1 67a 178967 .WASHER, silver–colored 1 67b 107089 .WASHER, bronze–colored 1 68 176817 SPRING, retaining 1 70 239984 HOSE, grounded, nylon,1/4 in. ID 1 cpld 1/4 npsm (f), 25 in. (635 mm), spring guards both ends 73 MOTOR, ELECTRIC 1 includes 41 240994* Ultra Max 795, Model 232144 1 240566* Ultra Max 1095, Model 232154 1 240015* Ultra Max 795, Model 232148 1 240034* Ultra Max 1095, Model 232158, 156 1 77 239998 HANDLE, cart 1 78 239980 FRAME, sprayer 1 84 114271 STRAP, retaining 1 85 240144 HOSE, drain 1 90 100069 BALL, steel, 1/4 in. dia. 2 120 238361 HOSE, grounded, nylon, 1/4 in. ID, 1 cpld 1/4 npsm(f), 50 ft (15 m) spring guards both ends 121 238358 HOSE, grounded, nylon, 3/16 in. ID, 1 cpld 1/4 npsm(f), 3 ft (.9 m), spring guards both ends 122 222667 SPRAY GUN 1 see manual 307614 for parts 123 192838 LABEL, WARNING, French 1 126 LABEL, WARNING 1 187975 English 1 189699 Japanese 1
Extra Danger and Warning tags and labels available free. *Motor Brush Repair Kit 220853 is available. Order separately. Not part of Model 232156

Ultra MAX 795 and 1095 Lo-Boy Sprayers Model 232145, Series A Model 232157, Series A


Ultra MAX 795 and 1095 Lo-Boy Sprayers Model 232145, Series A; Model 232157, Series A
REF NO. PART NO. DESCRIPTION QTY
10 110996 NUT, flange head, hex 1 14 101242 RING, retaining 2 16 100644 SCREW, socket head, 1/4–20 x 3/4 in. 4 19 104811 HUBCAP 2 20 105510 LOCKWASHER, spring, 1/4 in. 6 21 106062 WHEEL, semi–pneumatic 2 22 240523 HOUSING, bearing 1 23 106115 LOCKWASHER, spring, 3/8 in. 4 24 114406 SCREW, self tap, filnd 1 25 107210 CAPSCREW, sch, 3/8–16 x 1–1/2 in. 4 26 107218 CAPSCREW, sch, 1/4–20 x 2–3/4 in. 4 30 111801 SCREW, cap, flange hd 7 32 222667 SPRAY GUN see manual 307614 for parts 1 33 108691 PLUG, tubing 2 34 108865 SCREW, pan head, no. 8 x 3/8 in. 6 35 109032 SCREW, pnhd, 10–32 x 1/4 in. 4 37 110243 RING, retaining 2 40 162453 NIPPLE, 1/4 npt(m) x 1/4 npsm 2 41 LABEL, WARNING 2 187791 English 2 189702 Japanese 2 42 238358 HOSE, grounded, nylon, 3/16 in. ID, cpld 1/4 npsm(f), 3 ft (.9 m), spring guards both ends 1 43 238361 HOSE, grounded, nylon, 1/4 in. ID, cpld 1/4 npsm(f), 50 ft (15 m) spring guards both ends 1 45 181072 STRAINER 1 47 192723 NUT, retaining 1 48 112827 BUTTON, snap 2 49 188154 COVER, housing 1 50 193347 COVER, display, painted 1 51 179961 REDUCER, gear 1 52 183350 WASHER 1 59 SHIELD, motor 1 240317 Ultra MAX 795 1 240313 Ultra MAX 1095 1 62 192027 SLEEVE, cart 2 63 218034 KIT, rod, connecting 1
64 239923 PUMP, displacement 1 see manual 308798 for parts 65 206994 THROAT SEAL LIQUID, 8 OZ 1 66 176818 PIN, straight, hdls, 1 0.3125 in. dia x 1.023 in. 67 DRIVE HOUSING 1 includes replaceable items 67a and 67b 239931 Ultra Max 795, Model 232145 1 218032 Ultra Max 1095, Model 232157 1 67a 178967 .WASHER, silver–colored 1 67b 107089 .WASHER, bronze–colored 1 68 176817 SPRING, retaining 1 70 239984 HOSE, grounded, nylon,1/4 in. ID 1 cpld 1/4 npsm (f), 29 in. (715 mm), spring guards both ends 72 170957 TUBE, suction 1 73 MOTOR, ELECTRIC 1 240994* Ultra Max 795, Model 232145 1 240034* Ultra Max 1095, Model 232157 1 77 193247 HANDLE, cart 1 78 240512 FRAME, cart 1 83 240513 SWIVEL, inlet tube 1 85 192727 HOSE, drain 1 90 100069 BALL 1 103 101818 CLAMP, hose 1 104 192691 CLIP, spring 1 105 103473 STRAP, tie 3 106 205473 COUPLING, hose 1 111 170706 HOSE, suction 1 123 192838 LABEL, WARNING, French 1 126 LABEL, WARNING 1 187975 English 1 189699 Japanese 1
Extra Danger and Warning tags and labels available free.
*Motor Brush Repair Kit 220853 is available. Order separately. Not part of Model 232157

Ultra MAX 795 and 1095 Sprayers Model 232144, Series A Model 232145, Series A Model 232148, Series A Model 232154, Series A Model 232156, Series A Model 232157, Series A Model 232158, Series A


Ultra MAX 795 and 1095 Sprayers Models 232144, Series A; 232145, Series A; 232148, Series A Models 232154, Series A; 232158, Series A; 232157, Series A; 232156, Series A REF NO. PART NO. DESCRIPTION QTY
4 224807 ASSEMBLY, cam, drain valve 1 5 111600 PIN, grooved 1 6 187625 HANDLE, valve, drain 1 7 111699 GASKET, seat, valve 1 8 BOARD, filter 1 240557 Models 232144, 145, 154 1 240723 Models 232148, 158 1 9 104361 O-RING, packing 1 12 167025 STRAINER, mesh, 60 1 28 114392 SCREW, mach, panhd 5 31 240314 TRANSDUCER, pressure control 1 includes item 59 46 114528 SCREW, mach, panhd 2 50 100020 WASHER, lock spring 4 55 112538 ELBOW, 90, street, reducing 1 59 111457 O-RING, packing 1 69 240315 BOWL, filter; includes item 72 1 71 187615 VALVE, seat 1 72 171941 SPRING, compression 1 74 235014 ASSEMBLY, drain valve 1 75 100721 PLUG, pipe 1 76 186075 SUPPORT, filter 1 79 CORD SET, power (see note, page 22) 1 240539 Continental Europe (CEE 7/7) 1 240540 Italy 1 239050 United Kingdom 1 240543 None (Bare End) 1 240721 Japan 1 241879 Australia 1 80 SWITCH, rocker, (dpst) 1 114518 Model 232144, 145, 148, 154, 158 1 114277 Model 232156, 157 1 81 114273 KNOB, potentiometer 1 82 240527 COVER, control box, painted 1
85 240144 HOSE, drain 1 86 240316 HOUSING, filter; includes item 9 1 87 107183 CAPSCREW 4 89 192726 PLATE, housing, control 1 91 107505 PACKING, o-ring 1 92 164672 ADAPTER 2 97 HOUSING, control box 1 193239 Model 232144, 145, 154 1 192694 Model 232148, 158, 156, 157 1 98 BUSHING, strain relief 1 113799 Model 232144, 145, 154 1 114284 Model 232148, 158, 156, 157 1 99 114689 BUSHING, strain relief 1 100 240131 CAP, for secondary outlet 1 101 192831 PLATE, instruction 1 102 114420 SCREW, mach, pnhd 4 104 BOARD, PC 1 240561 Model 232144, 145, 154 1 240168 Model 232148, 158, 156, 157 1 105 236352 POTENTIOMETER, pressure adjust 1 106 112382 NUT, shaft, sealing 1 107 114391 SCREW, ground 1 112 114393 SCREW 3 115 LABEL, warning 1 193051 English 1 193520 Japanese 1 116 114652 BUSHING, strain relief 1 127 193347 COVER, display, painted 1 128 164736 PIN, cross 1 129 240544 BOARD, circuit, display 1 130 193348 LABEL, graphic, display 1 131 103739 WASHER, lock, int 1 132 114512 SCREW, mach, panhd, 4–40 x 3/8 1 133 192149 RETAINER, cord 1 134 193497 GASKET 2 Extra Danger and Warning tags and labels available free. *Motor Brush Repair Kit 220853. Order separately.
TP2
Heat from inductor coil of filter board may destroy wire insulation that comes in contact with it. Exposed wires could cause shorts and component damage. Bundle and tie all loose wires so none lay in contact with inductor coil of filter board.
TP1
Filter Board Red (+) Black (–)
8100B Fig. 17

Technical Data
Power Requirements Model 232144, 145, 154 230 VAC, 50 Hz, 1 phase, 10A minimum or 4000W generator Model 232148, 158 110 VAC, 50 Hz, 1 phase, 15A minimum or 4000W generator Model 232156, 157 100 VAC, 50/60 Hz, 1 phase, 15A minimum or 4000W generator Motor
Ultra Max 795 1.0 HP
with latex at 2000 psi (138 bar, 13.8 MPa) Ultra Max 1095 1.2 HP
Apply other language here
with latex at 2000 psi (138 bar, 13.8 MPa) Working Pressure Range 0–3000 psi (0–210 bar, 0–21 MPa) Cycles/Gallon (liter)
French 185955 Spanish 185962 German 186042 Greek 186046 Korean 186050
Ultra Max 795 244 (64.6) Ultra Max 1095 200 (53) Maximum Delivery Rating
Ultra Max 795 0.8 gpm (3 lpm) Ultra Max 1095 1.1 gpm (4.1 lpm) Tip Size
Ultra Max 795 one gun – 0.028; two guns – 0.019
with latex at 2000 psi (138 bar, 13.8 MPa) Ultra Max 1095 one gun – 0.032; two guns – 0.021
with latex at 2000 psi (138 bar, 13.8 MPa) Power Cord 14 AWG (1.5 mm2), 3 wire, 15 ft (4.5 m) Inlet Paint Strainer 16 mesh (975 micron)
stainless steel screen, reusable Outlet Paint Filter 60 mesh (238 micron)
stainless steel screen, reusable
) m (t p n 4 / 3 e zi S t eln I p m u P Fluid Outlet Size
8 / 3 r e tli F npt(f) Filter with standard 3/8 npt(f) to 1/4 npsm adapter 1/4 npsm Sound Data
*) A ( B d 0 0 1 le v e L r e w o P d n u o S
*) A ( B d 0 9 le v e L e r u s s e r P d n u o S * Measured while spraying waterbase paint – specific gravity 1.36 through a 0.019 tip at 3000 psi (207 bar). Per ISO 3744 Basic Sprayer Wetted Parts: zinc-plated carbon steel, polyurethane, polyethylene, stainless steel,
Delrin , chrome plating, leather, V-Max UHMWPE, aluminum, stainless steel, tungsten carbide NOTE: Delrin is a registered trademark of the DuPont Co.
) g k 6 4 ( bl 1 0 1 5 9 7 x a M a rtl U
) g k 9 4 ( bl 7 0 1 5 9 0 1 x a M a rtl U
) m m 4 2 7 ( . ni 5 . 8 2 t h gie H
) m m 8 4 6 ( . ni 5 . 5 2 h t g n e L
) m m 1 2 5 ( . ni 5 . 0 2 h t di W Graco Phone Number
TO PLACE AN ORDER, contact your Graco distributor.
All written and visual data contained in this document reflect the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
www.graco.com PRINTED IN USA 308842 May 1998, Revised 2/2003
Weight ·
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Basic Fluid Pressure Problems | 1. Pressure control knob setting. Motor will not run if at minimum setting (fully counterclockwise). | p.4 | |
| Basic Fluid Pressure Problems | 2. For clogged spray tip or fluid filter. Refer to sepa- rate gun, tip, or fluid filter instruction manual. | p.4 | |
| Basic Mechanical Problems | 1. For frozen or hardened paint in pump (64). Use a screwdriver and carefully rotate fan at back of motor by hand. See page 9. | p.4 | |
| Basic Mechanical Problems | 2. Displacement pump connecting rod pin (66). Pin must be completely pushed into connecting rod (63) and retaining spring (68) must be firmly in groove of connecting rod. See Fig. 12. | p.4 | |
| Basic Mechanical Problems | 3. For motor damage. Remove drive housing as- sembly (67). See page 15. Try to rotate fan by hand. | p.4 | |
| Basic Electrical Problems | 1. Pressure control safety circuit. | p.4 | |
| Basic Electrical Problems | 2. Electrical supply. Meter must read: 210–250 VAC for models 232144, 145, 154. 100–120 VAC for models 232148, 158. 90–110 VAC for models 232156, 157. | p.4 | |
| Basic Electrical Problems | 3. Extension cord for damage. Check extension cord continuity with volt meter. | p.4 | |
| Basic Electrical Problems | 4. Sprayer power supply cord (79) for damage such as broken insulation or wires. | p.4 | |
| Basic Electrical Problems (continued) | 1. That motor leads are securely fastened and properly mated. | p.5 | |
| Basic Electrical Problems (continued) | 2. For loose motor brush lead connections and ter- minals. See page 9. | p.5 | |
| Basic Electrical Problems (continued) | 3. Brush length which must be 1/2 in. minimum. See page 9. NOTE: Brushes do not wear at the same rate on both sides of motor. Check both brushes. | p.5 | |
| Basic Electrical Problems (continued) | 4. For broken or misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush. See page 9. | p.5 | |
| Basic Electrical Problems (continued) | 5. Motor brushes for binding in brush holders. See page 9. | p.5 | |
| Basic Electrical Problems (continued) | 6. Motor armature commutator for burn spots, gouges and extreme roughness. See page 9. | p.5 | |
| Basic Electrical Problems (continued) | 7. Motor armature for shorts using armature tester (growler) or perform spin test. See page 9. | p.5 | |
| Basic Electrical Problems (continued) | 8. Motor control board (104) by performing motor control board diagnostics on page 12. If diag- nostics indicate, substitute with a good board. CAUTION: Do not perform this check until mo- tor armature is determined to be good. A bad motor armature can burn out a good board. | p.5 | |
| Refer to wiring diagram on page 23 to identify test points (TP). | 1. Power supply cord (79). Connect volt meter be- tween TP1 (neutral) and TP2. Plug in sprayer. Meter must read: 210–250 VAC for models 232144, 145, 154. 100–120 VAC for models 232148, 158. 90–110 VAC for models 232156, 157. Unplug sprayer. | p.5 | |
| Refer to wiring diagram on page 23 to identify test points (TP). | 2. ON/OFF switch (80). Connect volt meter be- tween TP1 and TP3 terminal on ON/OFF switch. Plug in sprayer and turn ON. Meter must read: 210–250 VAC for models 232144, 145, 154. 100–120 VAC for models 232148, 158. 90–110 VAC for models 232156, 157. Turn off and unplug sprayer. Reconnect TP3 | p.5 | |
| Refer to wiring diagram on page 23 to identify test points (TP). | 3. Motor thermal cutoff switch. Turn sprayer OFF. Check for continuity between TP4 and TP5 with ohmmeter. | p.5 | |
| Refer to wiring diagram on page 23 to identify test points (TP). | 4. All terminals for damage or loose fit. | p.5 | |
| Low Output | 1. For worn spray tip. | p.6 | |
| Low Output | 2. Verify pump does not continue to stroke when gun trigger is released. Plug in and turn on sprayer. Prime with paint. Trigger gun momen- tarily, then release and lock safety latch. Relieve pressure, turn off and unplug sprayer. | p.6 | |
| Low Output | 3. Electrical supply with volt meter. Meter must read: 210–250 VAC for models 232144, 145, 154. 100–120 VAC for models 232148, 158. 90–110 VAC for models 232156, 157. | p.6 | |
| Low Output | 4. Extension cord size and length; must be at least 12 gauge wire and no longer than 300 ft. | p.6 | |
| Low Output | 5. Leads from motor to pressure control circuit board (104) for damaged or loose wires or con- nectors. Inspect wiring insulation and terminals for signs of overheating. | p.6 | |
| Low Output | 6. For loose motor brush leads and terminals. See page 9. | p.6 | |
| Low Output | 7. For worn motor brushes which must be 1/2 in. minimum. See page 9. | p.6 | |
| Low Output | 8. For broken and misaligned motor brush springs. Rolled portion of spring must rest squarely on top of brush. | p.6 | |
| Low Output | 9. Motor brushes for binding in brush holders. See page 9. | p.6 | |
| Low Output | 10.Stall pressure. | p.6 | |
| Low Output | 11.Motor armature for shorts by using an armature tester (growler) or perform spin test. See page 9. | p.6 | |
| Low Output | 12.Motor control board (104) by performing motor control board diagnostics on page 12. If diag- nostics indicate, substitute with a good board. CAUTION: Do not perform this check until mo- tor armature is determined to be good. A bad motor armature can burn out a good board. | p.6 | |
| Motor runs and pump strokes | 1. Paint supply. | p.7 | |
| Motor runs and pump strokes | 2. For clogged intake strainer. | p.7 | |
| Motor runs and pump strokes | 3. For loose suction tube or fittings. | p.7 | |
| Motor runs and pump strokes | 4. To see if intake valve ball and piston ball are seating properly. See page 17. | p.7 | |
| Motor runs and pump strokes | 5. For leaking around throat packing nut which may indicate worn or damaged packings. See page 17. | p.7 | |
| Motor runs but pump does not stroke | 1. Displacement pump connecting rod pin (66). See page 17. | p.7 | |
| Motor runs but pump does not stroke | 2. Connecting rod assembly (63) for damage. See page 14. | p.7 | |
| Motor runs but pump does not stroke | 3. Be sure crank in drive housing rotates; plug in sprayer and turn on briefly to check. Turn off and unplug sprayer. See page 15. | p.7 | |
| Spray pattern variations. | 1. Be sure leads to motor control board are firmly connected. Be sure all male terminal blades are centered and firmly connected to female terminals. See Fig. 17. | p.7 | |
| Spray pattern variations. | 2. Maximum working pressure. | p.7 | |
| Spray pattern variations. | 3. Motor control board (104) by performing motor control board diagnostics on page 12. If diag- nostics indicate, substitute with a good board. CAUTION: Do not perform this check until motor armature is determined to be good. A bad motor armature can burn out a good board. | p.7 | |
| Spray pattern variations. | 4. Check LOW OUTPUT section, page 6. | p.7 | |
| Motor is hot and runs intermit- tently. | 1. Determine if sprayer was operated at high pressure with small tips, which causes low motor RPM and excessive heat build up. | p.8 | |
| Motor is hot and runs intermit- tently. | 2. Be sure ambient temperature where sprayer is located is no more than 90F and sprayer is not located in direct sun. | p.8 | |
| Motor is hot and runs intermit- tently. | 3. Determine if sprayer was turned on, pressur- ized, but not operating for long periods of time. | p.8 | |
| Building circuit breaker opens as soon as sprayer switch is turned on. CAUTION Any short in any part of the motor power circuit will cause the control circuit to inhibit sprayer operation. Correctly diagnose and repair all shorts before checking and replac- ing control board. | 1. All electrical wiring for damaged insulation, and all terminals for loose fit or damage. Also wires between pressure control and motor. See page 16. | p.8 | |
| Building circuit breaker opens as soon as sprayer switch is turned on. CAUTION Any short in any part of the motor power circuit will cause the control circuit to inhibit sprayer operation. Correctly diagnose and repair all shorts before checking and replac- ing control board. | 2. For missing inspection plate gasket (see page 16), bent terminal forks or other metal to metal contact points which could cause a short. | p.8 | |
| Building circuit breaker opens as soon as sprayer switch is turned on. CAUTION Any short in any part of the motor power circuit will cause the control circuit to inhibit sprayer operation. Correctly diagnose and repair all shorts before checking and replac- ing control board. | 3. Motor armature for shorts. Use an armature tester (growler) or perform spin test. See page 9. Inspect windings for burns. | p.8 | |
| Building circuit breaker opens as soon as sprayer switch is turned on. CAUTION Any short in any part of the motor power circuit will cause the control circuit to inhibit sprayer operation. Correctly diagnose and repair all shorts before checking and replac- ing control board. | 4. Motor control board (104) by performing motor control board diagnostics on page 12. If diag- nostics indicate, substitute with a good board. CAUTION: Do not perform this check until mo- tor armature is determined to be good. A bad motor armature can burn out a good board. | p.8 | |
| Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on. | 1. Basic Electrical Problems on page 4. | p.8 | |
| Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on. | 2. ON/OFF switch (80) See page 11. Be sure sprayer is unplugged! Disconnect wires from switch. Check switch with ohmmeter. Reading must be infinity with ON/OFF switch OFF, and zero with switch ON. | p.8 | |
| Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on. | 3. For damaged or pinched wires in pressure con- trol. See page 12. | p.8 | |
| Sprayer quits after sprayer op- erates for 5 to 10 minutes. | 1. Basic Electrical Problems on page 4. | p.8 | |
| Sprayer quits after sprayer op- erates for 5 to 10 minutes. | 2. Electrical supply with volt meter. Meter must read: 210–250 VAC for models 232144, 145, 154. 100–120 VAC for models 232148, 158. 90–110 VAC for models 232156, 157. | p.8 | |
| Sprayer quits after sprayer op- erates for 5 to 10 minutes. | 3. Tightness of pump packing nut. Over tightening tightens packings on rod, restricts pump action, and damages packings. | p.8 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.