695 / 795 / 1095 / 1595 / Mark IV / Mark V / Mark VII / Mark X Electric Airless Sprayers
For Portable Airless Spraying of Architectural Coatings and Paints. For professional use only. Not approved for use in European explosive atmosphere locations.
3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure



UltraMax II, Ultimate Max II Models:
Models

Models

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
GROUNDING This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.









Component Identification

Do not modify plug! If it will not fit in outlet, have grounded outlet installed by a qualified electrician. Do not use an adapter.

The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.
The sprayer cord includes a grounding wire with an appropriate grounding contact. Do not use the sprayer if the electrical cord has a damaged ground contact.
Use an extension cord with an undamaged ground contact.
If an extension cord is necessary, use a 3-wire, 12 AWG (2.5 mm2) minimum. Longer cords and higher gauge cords reduce sprayer performance.
The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Grounding


Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a grounded sur- face such as concrete.
Do not place pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity.
Select 10A or 16A setting based on your circuit rating.
Grounding a metal pail: connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground.
Select 15A or 20A setting based on your circuit rating.
To maintain grounding continuity when flushing or relieving pressure: hold metal part of spray gun firmly to side of a grounded metal pail. Then trigger gun.
10/16 Amp Switch

Follow the Pressure Relief Procedure whenever you see this symbol.
This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.
Pressure Relief Procedure

If using the optional hopper, remove the nipple fit- ting from the filter. Install 45° elbow (from parts box) into filter and install nipple fitting into elbow. Then connect the hose to the nipple.



High-pressure spray is able to inject toxins into the body and cause serious bodily injury. Do not stop leaks with hand or rag.

Startup

Spray

SKIN INJECTION HAZARD Never point gun at your hand or into a rag!
Switch Tip Installation

Fast Flush (ProContractor and IronMan models only)
WatchDog ™ Protection System (ProContractor and IronMan models only)
To flush the hose and gun at an accelerated speed, per- form the following steps:
Pump stops automatically when material pail is empty.

To Activate:



This sprayer protects itself against high and low voltage. If the sprayer is plugged into a power source that is too low or too high the sprayer will stop operating.
One of three error codes will be displayed:
Standard models come equipped with a ProGuard sta- tus indicator light. This light has three different states of operation: ON, blink, and OFF.
Multiple incoming voltage surges detected - unplug sprayer and locate good voltage supply to prevent damage to electronics. Typical cause of this error is plugging into a circuit that is higher than the rated voltage of the sprayer. Find a circuit that supplies the correct voltage.

Light is ON Unit is powered and operating normally.
Incoming voltage too low for sprayer operation - unplug sprayer and locate good voltage supply to prevent damage to electronics. Typical cause of this error is other equipment on the same circuit or generator frequently turning on/off under load. Find a circuit that is dedicated to the sprayer.
Light is Blinking Voltage supply is too low or too high for sprayer and will not run until it is plugged into a good power supply.
Light is OFF No power to sprayer, or there is another error other than the voltage supply.
Sprayer plugged into wrong voltage - unplug sprayer and locate correct voltage supply. Typical cause of this error is a GFCI box that is wired for the wrong voltage (240V vs. 120V). No damage has occurred to the sprayer. Find a circuit with the correct voltage and the sprayer will run correctly.
See Troubleshooting (page 24) to determine the cause of any errors.

ProGuard · Error Code Definition


Moving parts can pinch, cut or amputate fingers and other body parts. To avoid injury from moving parts, be sure to keep your head clear of hose reel while winding up hose.
Hose Reel

Digital Tracking System (ProContractor and IronMan models only)
Job Gallons

Short press to move to next display. Press and hold (5 seconds) to change units or reset data.



Press and hold DTS button for 5 seconds to change pressure units (psi, bar, MPa) to desired units. Selec- tion of bar or MPa changes gallons to liters x 10. To change display units DTS must be in pressure display mode and pressure must be at zero.


Digital Tracking System (ProContractor and IronMan models only)



0 695 2 795 / Mark IV 4 1095 / 230V Mark V 6 1595 / 120V Mark V / MARK VII 10 Mark X




Cleanup · ti18249a ti22944a



Cleanup · Pump Armor

Mechanical/Fluid Flow
Perform Pressure Relief Procedure; page 13.
WHAT TO CHECK If check is OK, go to next check
WHAT TO DO When check is not OK, refer to this column
For units with display: CODE XX is displayed.
Fault condition exists Determine fault correction from table, page 27.
For units with no display: ProGuard status light is blinking or the light is off and there is power to the sprayer.
Pump output is low Spray tip worn Follow Pressure Relief Procedure on page 13, then replace tip. See your separate gun or tip manual.
Spray tip clogged Relieve pressure. Check and clean spray tip.
Paint supply Refill and reprime pump.
Intake strainer clogged Remove and clean, then reinstall
Intake valve ball and piston ball are not seating properly
Remove intake valve and clean. Check balls and seats for nicks; replace if necessary; see pump manual. Strain paint before using to remove particles that could clog pump.
Fluid filter, tip filter, or tip is clogged or dirty.
Clean filter; see operation manual.
Prime valve leaking Relieve pressure. Repair prime valve.
Verify pump does not continue to stroke when gun trigger is released. (Prime valve not leaking.)
Service pump; see pump manual.
Leaking around throat packing nut which may indicate worn or damaged packings.
Replace packings; see pump manual. Also check piston valve seat for hardened paint or nicks and replace if necessary. Tighten pack- ing nut/wet-cup.
Troubleshooting

WHAT TO CHECK If check is OK, go to next check
WHAT TO DO When check is not OK, refer to this column
Pump output is low Pump rod damage Repair pump. See pump manual.
Low stall pressure Turn pressure knob fully clockwise. Make sure pressure control knob is properly installed to allow full clockwise position. If problem per- sists, replace pressure transducer.
Piston packings are worn or dam- aged
Replace packings; see pump manual.
O-ring in pump is worn or damaged Replace o-ring; see pump manual.
Intake valve ball is packed with mate- rial
Clean intake valve; see pump manual.
Pressure setting is too low Increase pressure; see pump manual.
Large pressure drop in hose with heavy materials
Use larger diameter hose and/or reduce overall length of hose.
Check to see if Amp switch (10/16 or 15/20) is on low setting. Make sure circuit is able to provide high setting.
Switch to 16A or 20A setting. Change to circuit that provides 16A or 20A. Change to less loaded circuit.
Motor runs but pump does not stroke
Displacement pump pin damaged or missing; see pump manual.
Replace pump pin if missing. Be sure retainer spring is fully in groove all around connecting rod; see pump manual.
Connecting rod assembly damaged; see pump manual.
Replace connecting rod assembly; see pump manual.
Gears or drive housing damaged. Inspect drive housing assembly and gears for damage and replace if necessary; see pump manual.
Excessive paint leakage into throat packing nut
Throat packing nut is loose Remove throat packing nut spacer. Tighten throat packing nut just enough to stop leakage.
Throat packings are worn or dam- aged
Replace packings; see pump manual.
Displacement rod is worn or dam- aged
Replace rod; see pump manual.
Fluid is spitting from gun Air in pump or hose Check and tighten all fluid connections. Cycle pump as slowly as possible during priming.
Fluid supply is low or empty Refill fluid supply. Prime pump; see pump man- ual. Check fluid supply often to prevent running pump dry.
Troubleshooting

WHAT TO CHECK If check is OK, go to next check
WHAT TO DO When check is not OK, refer to this column
Pump is difficult to prime Air in pump or hose Check and tighten all fluid connections. Cycle pump as slowly as possible during priming.
Intake valve is leaking Clean intake valve. Be sure ball seat is not nicked or worn and that ball seats well. Reas- semble valve.
Pump packings are worn Replace pump packings; see pump manual.
Paint is too thick Thin the paint according to supplier recommen- dations.
No display, sprayer operates
Display is damaged or has bad con- nection
Check connections. Replace display.
Troubleshooting

ProGuard Status Light Control Board Status Light
Symptom: Sprayer does not run, stops running, or will not shut off.

Perform Pressure Relief Procedure; page 13.
For units without a display, see ProGuard (page 18). If there is a voltage supply issue (CODE 04, 08, or 17), the ProGuard status light will blink continuously when the ON/OFF switch is ON. To determine which code (or any other code besides voltage supply) refer to the control board status light. Turn the ON/OFF switch OFF, remove the control cover then turn power back ON. Observe the status light. Blinking LED total count equals the error code (for example: two blinks equals CODE 02).
Keep clear of electrical and moving parts during trou- bleshooting procedures. To avoid electrical shock haz- ards when covers are removed for troubleshooting, wait 5 minutes after unplugging power cord for stored elec- tricity to dissipate.
TYPE OF PROBLEM WHAT TO CHECK HOW TO CHECK
Sprayer does not run at all See flow chart, page 33.
ProGuard status light and control board status light never light
Sprayer does not run at all Check transducer or transducer connections
Display shows CODE 02
Control board status light blinks 2 times repeatedly
Troubleshooting · Display is blank

TYPE OF PROBLEM WHAT TO CHECK HOW TO CHECK
Sprayer does not run at all Check transducer or transducer connections (control board is not detecting a pressure signal).
Display shows CODE 03
Control board status light blinks 3 times repeatedly
Sprayer does not run at all Check voltage supply to the sprayer (control board is detecting a multiple voltage surges).
Display shows CODE 4
Control board status light blinks four times repeatedly
Troubleshooting

TYPE OF PROBLEM WHAT TO CHECK HOW TO CHECK
Sprayer does not run at all Control is commanding motor to run but motor shaft does not rotate. Possibly locked rotor condition, an open connection exists between motor and control, there is a problem with motor or control board, or motor amp draw is excessive.
Display shows CODE 05
Control board status light blinks 5 times repeatedly
5. Perform Spin Test: Test at large 4-pin motor field connector. Disconnect fluid pump from sprayer. Test motor by placing a jumper across pins 1 & 2. Rotate motor fan at about 2 revolutions per second. A cogging resistance to motion should be felt at the fan. The motor should be replaced if no resistance is felt. Repeat for pin combinations 1 & 3 and 2 & 3. Pin 4 (the green wire) is not used in this test. If all spin test is positive, continue to step 6.
Green Blue Red Black
Green Blue Red Black
Green Blue Red Black
Troubleshooting

TYPE OF PROBLEM WHAT TO CHECK HOW TO CHECK
Sprayer does not run at all Control is commanding motor to run but motor shaft does not rotate. Possibly locked rotor condition, an open connection exists between motor and control, there is a problem with motor or control board, or motor amp draw is excessive.
Display shows CODE 05
Control board status light blinks 5 times repeatedly
Resistance Table:
695/240V Mark IV 0 ohms
795/120V Mark IV 2k ohms
1095/240V Mark V 3.9k ohms
1595/120V Mark V/MARK VII 6.2k ohms
MARK X 10.0k ohms
Troubleshooting

TYPE OF PROBLEM WHAT TO CHECK HOW TO CHECK
Sprayer does not run at all Allow sprayer to cool. If sprayer runs when cool, correct cause of overheating. Keep sprayer in cooler location with good ventilation. Make sure motor air intake is not blocked. If sprayer still does not run, follow Step 1.
Display shows CODE 06
Check Motor Thermal Switch: Unplug thermal wires. Set meter to ohms. Meter should read the proper resistance for each unit (see table below).
Control board status light blinks 6 times repeatedly
Resistance Table:
695/240V Mark IV 0 ohms
795/120V Mark IV 2k ohms
1095/240V Mark V 3.9k ohms
1595/120V Mark V/MARK VII 6.2k ohms
MARK X 10.0k ohms
Sprayer does not run at all Check voltage supply to the sprayer (incoming voltage too low for sprayer operation)
Display shows CODE 08
Control board status light blinks eight times repeatedly
Sprayer does not run at all Check to see if control board is over heating.
Display shows CODE 10
Control board status light blinks 10 times repeatedly
Troubleshooting


TYPE OF PROBLEM WHAT TO CHECK HOW TO CHECK
Sprayer does not run at all Excessive current protection enabled
Sprayer does not run at all Check the connections above the motor
Sprayer does not run at all Check the connections. Control is not receiving a motor position sensor signal
Sprayer does not run at all Check voltage supply to the sprayer (sprayer plugged into wrong voltage)
Troubleshooting

Sprayer Will Not Run (See following page for steps)

Remove control box cover. Turn sprayer ON. Observe control board status light on control board (see page 27).
retest. If Step 3 still shows incorrect resistance, replace
Troubleshooting


Troubleshooting

Plumb pressure gauge into paint hose, plug sprayer in, and turn power
switch ON. Does sprayer reach or
further trouble shooting procedures.
exceed its maximum pressure?
Unplug the transducer from control
Replace the control board.
board. Does motor stop running?
Bad transducer. Replace and test
with a new one.
Troubleshooting · Troubleshooting Procedure

695 Sprayers U.S. Metric
North American Models 0.95 gpm 3.6 lpm International Models 0.75 gpm 2.8 lpm Maximum Tip Size 0.031 0.031 Fluid Outlet npsm 1/4 in. 1/4 in. Cycles 226 per gallon 60 per liter Generator Minimum 5000 W 5000 W 120V, A, Hz 14.8, 50/60 14.8, 8, 50/60 230V, A, Hz 9, 50/60 9, 50/60 Dimensions
Weight:
Standard Series Lo-Boy 94 lb 43 kg Standard Series Hi-Boy 94 lb 43 kg ProContractor 111 lb 50 kg Height:
Standard Series Lo-Boy 27.5 in. 69.9 cm
Standard Series Hi-Boy 28.5 in. (Handle down) 38.75 in. (Handle up) 72.4 cm (Handle down) 98.4 cm (Handle up) ProContractor 39 in. 99 cm Length:
Standard Series Lo-Boy 37 in. 94 cm Standard Series Hi-Boy 26 in. 66 cm ProContractor 29.5 in. 75 cm Width: 22.5 in. 57.2 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer · Maximum Delivery

North American Models 1.1 gpm 4.2 lpm International Models 0.95 gpm 3.6 lpm Maximum Tip Size 0.033 0.033 Fluid Outlet npsm 1/4 in. 1/4 in. Cycles 195 per gallon 52 per liter Generator Minimum 5000 W 5000 W 120V, A, Hz 15, 50/60 15, 50/60 230V, A, Hz 10, 50/60 10, 50/60 Dimensions
Weight:
Standard Series Lo-Boy 98 lb 45 kg Standard Series Hi-Boy 98 lb 45 kg ProContractor 115 lb 52 kg Height:
Standard Series Lo-Boy 27.5 in. 69.9 cm
Standard Series Hi-Boy 28.5 in. (Handle down) 38.75 in. (Handle up) 72.4 cm (Handle down) 98.4 cm (Handle up) ProContractor 39 in. 99 cm Length:
Standard Series Lo-Boy 37 in. 94 cm Standard Series Hi-Boy 26 in. 66 cm ProContractor 29.5 in. 75 cm Width: 22.5 in. 57.2 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer · Maximum Delivery

North American Models 1.2 gpm 4.5 lpm International Models 1.1 gpm 4.1 lpm Maximum Tip Size 0.035 0.035 Fluid Outlet npsm 1/4 in. 1/4 in. Cycles 123 per gallon 33 per liter Generator Minimum 5000 W 5000 W 120V, A, Hz 15, 50/60 15, 50/60 230V, A, Hz 10, 50/60 10, 50/60 Dimensions
Weight:
Standard Series Hi-Boy 120 lb 55 kg ProContractor 141 lb 64 kg IronMan 127 lb 58 kg Height:
Standard Series Hi-Boy 29.5 in. (Handle down) 38.5 in. (Handle up) 74.9 cm (Handle down) 97.8 cm (Handle up) ProContractor 39 in. 99 cm IronMan 40.2 in. 102 cm Length:
Standard Series Hi-Boy 26 in. 66 cm ProContractor 28 in. 71 cm IronMan 29.9 in. 76 cm Width:
Standard Series Hi-Boy 24 in. 61 cm ProContractor 24 in. 61 cm IronMan 24.4 in. 62 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer · Maximum Delivery

Maximum Delivery 1.35 gpm 5.1 lpm Maximum Tip Size 0.039 0.039 Fluid Outlet npsm 1/4 in. 1/4 in. Cycles 110 per gallon 29 per liter Generator Minimum 5000 W 5000 W 120V, A, Hz 20/15, 50/60 20/15, 50/60 Dimensions
Weight:
Standard Series Hi-Boy 125 lb 57 kg ProContractor 146 lb 66 kg IronMan 132 lb 60 kg Height:
Standard Series Hi-Boy 29.5 in. (Handle down) 38.5 in. (Handle up) 74.9 cm (Handle down) 97.8 cm (Handle up) ProContractor 39 in. 99 cm IronMan 40.2 in. 102 cm Length:
Standard Series Hi-Boy 26 in. 66 cm ProContractor 28 in. 71 cm IronMan 29.9 in. 76 cm Width:
Standard Series Hi-Boy 24 in. 61 cm ProContractor 24 in. 61 cm IronMan 24.4 in. 62 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer

North American Models 1.1 gpm 4.2 lpm International Models 0.95 gpm 3.6 lpm Maximum Tip Size
North American Models 0.033 0.033 International Models 0.031 0.031 Fluid Outlet npsm 3/8 in. 3/8 in. Cycles 195 per gallon 52 per liter Generator Minimum 5000 W 5000 W 120V, A, Hz 15, 50/60 15, 50/60 230V, A, Hz 10, 50/60 10, 50/60 Dimensions
Weight:
Standard Series Hi-Boy 98 lb 45 kg ProContractor 119 lb 54 kg Height:
Standard Series Hi-Boy 28.5 in. (Handle down) 38.75 in. (Handle up) 72.4 cm (Handle down) 98.4 cm (Handle up) ProContractor 39 in. 99 cm Length:
Standard Series Hi-Boy 26 in. 66 cm ProContractor 29.5 in. 75 cm Width: 22.5 in. 57.2 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer · Maximum Delivery

North American and UK Models 1.35 gpm 5.1 lpm International Models 1.2 gpm 4.5 lpm Maximum Tip Size
North American and UK Models 0.039 0.039 International Models 0.035 0.035 Fluid Outlet npsm 3/8 in. 3/8 in. Cycles 110 per gallon 29 per liter Generator Minimum 5000 W 5000 W 120V, A, Hz 20/15, 50/60 20/15, 50/60 230V, A, Hz 10, 50/60 10, 50/60 Dimensions
Weight:
Standard Series Hi-Boy 130 lb 59 kg ProContractor 151 lb 68 kg IronMan 137 lb 62 kg Height:
Standard Series Hi-Boy 29.5 in. (Handle down) 38.5 in. (Handle up) 74.9 cm (Handle down) 97.8 cm (Handle up) ProContractor 39 in. 99 cm IronMan 40.2 in. 102 cm Length:
Standard Series Hi-Boy 26 in. 66 cm ProContractor 28 in. 71 cm IronMan 29.9 in. 76 cm Width:
Standard Series Hi-Boy 24 in. 61 cm ProContractor 24 in. 61 cm IronMan 24.4 in. 62 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer · Maximum Delivery

Maximum Delivery 1.58 gpm 6.0 lpm Maximum Tip Size 0.041 in. 0.041 in. Fluid Outlet npsm 1/2 in. 1/2 in. Cycles 97 per gallon 26 per liter Generator Minimum 5000 W 5000 W 230V, A, Hz 16, 50/60 16, 50/60 Dimensions
Weight:
Standard Series Hi-Boy 139 lb 63 kg ProContractor 160 lb 73 kg Height:
Standard Series Hi-Boy 29.5 in. (Handle down) 38.5 in. (Handle up) 74.9 cm (Handle down) 97.8 cm (Handle up) ProContractor 39 in. 99 cm Length:
Standard Series Hi-Boy 26 in. 66 cm ProContractor 28 in. 71 cm Width: 24 in. 61 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer

Maximum Delivery 2.1 gpm 8.0 lpm Maximum Tip Size 0.045 in. 0.045 in. Fluid Outlet npsm 1/2 in. 1/2 in. Cycles 70 per gallon 19 per liter Generator Minimum 5000 W 5000 W 230V, A, Hz 16, 50/60 Dimensions
Weight:
Standard Series Hi-Boy 154 lb 70 kg ProContractor 178 lb 81 kg Height:
Standard Series Hi-Boy 29.9 in. (Handle down) 40.1 in. (Handle up) 76 cm (Handle down) 102 cm (Handle up) ProContractor 39 in. 99 cm Length:
Standard Series Hi-Boy 26 in. 66 cm ProContractor 30 in. 75 cm Width: 24 in. 61 cm
Wetted parts zinc- and nickel-plated carbon steel, nylon, stainless steel, PTFE, Acetal,
leather, UHMWPE, aluminum, tungsten carbide, PEEK, brass Noise Level:
Sound Power 91 dBa* 91 dBa* Sound Pressure 82 dBa* 82 dBa* *per ISO 3744; measured at 3.1 ft *per ISO 3744; measured at 1 m
Technical Data · Sprayer

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
For patent information, see www.graco.com/patents
TO PLACE AN ORDER, contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 332916
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revision C - March 2014
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| For units with display: CODE XX is displayed. For units with no display: ProGuard status light is blinking or the light is off and there is power to the sprayer. | Fault condition exists | p.24 | |
| Pump output is low | Spray tip worn | p.24 | |
| Pump output is low | Spray tip clogged | p.24 | |
| Pump output is low | Paint supply | p.24 | |
| Pump output is low | Intake strainer clogged | p.24 | |
| Pump output is low | Intake valve ball and piston ball are not seating properly | p.24 | |
| Pump output is low | Fluid filter, tip filter, or tip is clogged or dirty. | p.24 | |
| Pump output is low | Prime valve leaking | p.24 | |
| Pump output is low | Verify pump does not continue to stroke when gun trigger is released. (Prime valve not leaking.) | p.24 | |
| Pump output is low | Leaking around throat packing nut which may indicate worn or damaged packings. | p.24 | |
| Pump output is low | Pump rod damage | p.25 | |
| Pump output is low | Low stall pressure | p.25 | |
| Pump output is low | Piston packings are worn or dam- aged | p.25 | |
| Pump output is low | O-ring in pump is worn or damaged | p.25 | |
| Pump output is low | Intake valve ball is packed with mate- rial | p.25 | |
| Pump output is low | Pressure setting is too low | p.25 | |
| Pump output is low | Large pressure drop in hose with heavy materials | p.25 | |
| Pump output is low | Check to see if Amp switch (10/16 or 15/20) is on low setting. Make sure circuit is able to provide high setting. | p.25 | |
| Motor runs but pump does not stroke | Displacement pump pin damaged or missing; see pump manual. | p.25 | |
| Motor runs but pump does not stroke | Connecting rod assembly damaged; see pump manual. | p.25 | |
| Motor runs but pump does not stroke | Gears or drive housing damaged. | p.25 | |
| Excessive paint leakage into throat packing nut | Throat packing nut is loose | p.25 | |
| Excessive paint leakage into throat packing nut | Throat packings are worn or dam- aged | p.25 | |
| Excessive paint leakage into throat packing nut | Displacement rod is worn or dam- aged | p.25 | |
| Fluid is spitting from gun | Air in pump or hose | p.25 | |
| Fluid is spitting from gun | Tip is partially clogged | p.25 | |
| Fluid is spitting from gun | Fluid supply is low or empty | p.25 | |
| Pump is difficult to prime | Air in pump or hose | p.26 | |
| Pump is difficult to prime | Intake valve is leaking | p.26 | |
| Pump is difficult to prime | Pump packings are worn | p.26 | |
| Pump is difficult to prime | Paint is too thick | p.26 | |
| No display, sprayer operates | Display is damaged or has bad con- nection | p.26 | |
| Sprayer does not run at all | See flow chart, page 33. | p.27 | |
| Display is blank | p.27 | ||
| ProGuard status light and control board status light never light | p.27 | ||
| Sprayer does not run at all | Check transducer or transducer connections | p.27 | |
| Display shows CODE 02 | p.27 | ||
| Control board status light blinks 2 times repeatedly | p.27 | ||
| Display shows CODE 03 | p.28 | ||
| Control board status light blinks 3 times repeatedly | p.28 | ||
| Sprayer does not run at all | Check voltage supply to the sprayer (control board is detecting a multiple voltage surges). | p.28 | |
| Display shows CODE 4 | p.28 | ||
| Control board status light blinks four times repeatedly | p.28 | ||
| Sprayer does not run at all | Control is commanding motor to run but motor shaft does not rotate. Possibly locked rotor condition, an open connection exists between motor and control, there is a problem with motor or control board, or motor amp draw is excessive. | p.29 | |
| Display shows CODE 05 | p.29 | ||
| Control board status light blinks 5 times repeatedly | p.29 | ||
| Sprayer does not run at all | Allow sprayer to cool. If sprayer runs when cool, correct cause of overheating. Keep sprayer in cooler location with good ventilation. Make sure motor air intake is not blocked. If sprayer still does not run, follow Step 1. | p.31 | |
| Display shows CODE 06 | p.31 | ||
| Control board status light blinks 6 times repeatedly | p.31 | ||
| Sprayer does not run at all | Check voltage supply to the sprayer (incoming voltage too low for sprayer operation) | p.31 | |
| Display shows CODE 08 | p.31 | ||
| Control board status light blinks eight times repeatedly | p.31 | ||
| Sprayer does not run at all | Check to see if control board is over heating. | p.31 | |
| Display shows CODE 10 | p.31 | ||
| Control board status light blinks 10 times repeatedly | p.31 | ||
| Sprayer does not run at all | Excessive current protection enabled | p.32 | |
| Display shows CODE 12 | p.32 | ||
| Control board status light blinks 12 times repeatedly | p.32 | ||
| Sprayer does not run at all | Check the connections above the motor | p.32 | |
| Display shows CODE 15 | p.32 | ||
| Control board status light blinks 15 times repeatedly | p.32 | ||
| Sprayer does not run at all | Check the connections. Control is not receiving a motor position sensor signal | p.32 | |
| Digital display shows CODE 16 | p.32 | ||
| Control board status light blinks 16 times repeatedly | p.32 | ||
| Sprayer does not run at all | Check voltage supply to the sprayer (sprayer plugged into wrong voltage) | p.32 | |
| Display shows CODE 17 | p.32 | ||
| Control board status light blinks 17 times repeatedly | p.32 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.