EN
Gilson logo
Official user manual

Gilson Snow Blower (3)

2 pages·171 KB·Snow Blower·PDF·ENDEFRITNLJA
Gilson Snow Blower (3)
Table of Contents 12 sections Minipuls 3 Series Peristaltic Pumps · Gilson robustness and reliability! · ... wide range of flow-rates, · Peristaltic Pump · … ShowHide
Page 1 of the Gilson Snow Blower (3) user manual — Peristaltic Pump
Page 1 · click to enlarge
Page 1
Gilson Snow Blower (3) — Minipuls 3 Series Peristaltic Pumps diagram (page 1)
Fig. 1 · Minipuls 3 Series Peristaltic Pumps

Minipuls 3 Series Peristaltic Pumps

Gilson robustness and reliability!

High performance liquid transfer ...

... wide range of flow-rates,

Gilson Snow Blower (3) — ... wide range of flow-rates, diagram (page 1)
Fig. 2 · ... wide range of flow-rates,
Gilson Snow Blower (3) — ... wide range of flow-rates, diagram (page 1)
Fig. 3 · ... wide range of flow-rates,

Gilson, Inc., Gilson S.A.S., and Cyberlab, Inc. are ISO certified. ISO 9001 Certified

LT800443E. Printed in France, May 2003. Specifications subject to change without notice.

Gilson S.A.S. 19, avenue des Entrepreneurs - BP 145, 95400 Villiers le Bel, France Telephone: (33) 1-34-29-50-00 • Fax: (33) 1-34-29-50-20

World Headquarters Gilson, Inc. 3000 W. Beltline Hwy., P.O. Box 620027, Middleton, WI 53562-0027, USA Telephone: (1) 800-445-7661 or (1) 608-836-1551 • Fax: (1) 608-831-4451

World Wide Webwww.gilson.com E-mail: sales@ gilson.com , service@ gilson.com , training@ gilson.com

Weight 4 kg (9 lbs)

Dimensions (w x h x d) 15 x 18 x 17.5 cm (5.0 x 7.1 x 6.9 in)

Keypad functions Start, stop, direction of flow, increase and decrease flow, prime.

Input/Output Options Contact Closure: Two TTL-compatible inputs for control of start/stop and direction of flow Voltage Input: One 5 V analog signal for variable control of motor speed Serial: Gilson Serial Input/Output Channel (GSIOC), an RS-422A interface

Operating Temperature 0-40° C No warm-up time required

Power Consumption Full load 45 W at 220V; no load 35 W at 220V

Line Frequency 47 to 63 Hz

Line Voltage 90V to 132V for 110 voltage selection: 180V to 264V for 220 voltage selection

Motor Speed Stability 0.5% for any variation of line voltage, torque or temperature

Tubing materials PVC for most applications, Viton for chemical inertness, silicone for biocompatibility, and Pharmed(r) for FDA and USP class 4.

Peristaltic Tubing Diameter Standard Model: 0.25 to 4 mm (i.d.) High Flow Model: 2 to 8 mm (i.d.)

Head Speed Continuous adjustment from 0 to 48 rpm by 0.01 rpm increments up to 9.99 rpm and by 0.1 increments above 10 rpm

Pump Head Standard Model: 1,2,4 or 8 channel heads with 10 stainless steel rollers per head High Flow Model: 2 or 4 channel heads with 5 stainless steel rollers per head

Flow Rate Standard Model: 0.3 µL/min to 30 mL/min (72 psi/5 bar/0.5 MPa max) High Flow Model: 1 mL/min to 220 mL/min (42 psi/3 bar/0.3 MPa max)

R4/HF (high-flow) Pump Head F117831

R2/HF (high-flow) Pump Head F117830

R8 Pump Head F117608

R4 Pump Head F117606

R2 Pump Head F117800

R1 Pump Head F117604

Gilson’s Minipuls 3 is available as two parts: a speed control module and a pump head. An accessory package is suplied with the speed control module.

Peristaltic Pump

High Performance

Show 4 more labels / short text on this page
Technical Specifications · Speed-Control Module F155001 · Item Reference N° · Ordering Information
Page 2 of the Gilson Snow Blower (3) user manual — Reliable, Robust, Safe
Page 2 · click to enlarge
Page 2
Gilson Snow Blower (3) — Minipuls 3 Series ... ... the peristaltic pump, best performance! diagram (page 2)
Fig. 4 · Minipuls 3 Series ... ... the peristaltic pump, best…

Minipuls 3 Series the peristaltic pump, best performance!

Gilson Snow Blower (3) — Minipuls 3 Series ... ... the peristaltic pump, best performance! diagram (page 2)
Fig. 5 · Minipuls 3 Series ... ... the peristaltic pump, best…
  • By driving the liquid flow with as many as

Pulse Free Liquid Transfer

precision, even at high flow rates.

pulse free flows, with excellent accuracy and

10 rollers, Minipuls 3 is able to produce smoother,

  • The adjustable cams allow the
  • An adjustable speed stepper
Gilson Snow Blower (3) — Pulse Free Liquid Transfer diagram (page 2)
Fig. 6 · Pulse Free Liquid Transfer

systems.

the flow-rates of multichannel

when you want to synchonize

are possible, which may be useful

minor adjustments in flow rate

last longer. Also, by this means,

compressed to allow the tubing to

make priming easier or less

tubing to be overcompressed to

flow rates.

bore tubing assure reproducible

motor and high quality precision-

  • High flow:
  • Standard model:

pump head.

of the flow rate range that is available with each

gives you much greater flexibility in terms

A wide range of accepted tubing types and sizes

  • High flow pump-heads: choice of 2 or 4 channels.
  • Standard flow pump-heads: choice of 1, 2, 4,

your application or flow-rates requirements change.

So, you do not need to change the entire pump if

pressures, according to your application.

to accomodate a wide range of flow-rates and back

Choice of 6 fully interchangeable pump-heads

Wide Flow-rate Range (0.3 µL/min to 220 mL/min), Wide Tubing Size Range (0.25 mm to 8 mm ID)

(maximum pressure 0.3 MPa).

from 1 mL/min to 220 mL/min

(maximum pressure 0.5 MPa).

from 0.3 µL/min to 30 mL/min

or 8 channels.

Gilson Snow Blower (3) — Pulse Free Liquid Transfer diagram (page 2)
Fig. 7 · Pulse Free Liquid Transfer

and connectors to use for your application.

can provide support and advice on the best tubings

of laboratory equipment for liquid handling, Gilson

With its wide range of experience as a manufacturer

Gilson Support

reproducible flow rates are obtained.

tension in the peristaltic tubing is correct and that

of the tubing’s internal diameter, ensure that the

stops, which are color coded for easy recognition

changed easily and independently. The retaining

Just snap the cams! Tubing in any channel can be

Snappy Tubing Changes

interface (adapter required).

with most instruments possessing an RS232C

easy-to-read LCD screen.Remote control is possible

control, uncomplicated soft-touch keypad and

Simple operation thanks to its microprocessor

to maintain.

Minipuls 3 is easy to install, simple to operate, easy

Quiet, User Friendly

tubing rupture.

The built-in overflow is your protection in case of

even in the most challenging environments.

materials, Minipuls 3 ensures reliable liquid transfer

Solidly constructed from robust, chemically resistant

Reliable, Robust, Safe

Gilson Product, Quality Built-in

Ask about the Gilson Snow Blower (3)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Gilson Snow Blower (3)

Be the first to ask — other owners or our team will answer.

Original document

Gilson Snow Blower (3) manual PDF

2 pages·171 KB·Snow Blower·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…