2 DRYER SAFETY IMPORT ANT : When discar ding or storing your old clothes dryer , remove the door ..
3 INST ALLA TION REQUIREMENTS TOOLS AND P AR TS Gather the requir ed tools and parts before starting installation. T ools needed: Flat-blade screwdriver #2 Phillips screwdriver Adjustable wrench that .
4 DR YER DIMENSIONS Back view: 6 1 / 2 " (165 mm) 29 7 / 8 "* (759 mm) 3 1 / 2 "* (89 mm) 6 1 / 8 "* (156 mm) 14 3 / 8 " (365 mm) 3 / 4 "* (18 mm) NOTE: Most installations requir e a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow .
5 Installation spacing for recessed ar ea or closet installation All dimensions show recommended and minimum spacing allowed. ■ Additional spacing should be considered for ease of installation and servicing. ■ Additional clearances might be requir ed for wall, door , oor moldings, and dryer venting.
6 Then choose a 4-wire power supply cor d with ring or spade terminals and UL listed strain relief. The 4-wir e power supply cord, at least 4 ft. (1.22 m) long, must have four 10-gauge copper wires and match a 4-wir e receptacle of NEMA T ype 14-30R. The ground wir e (ground conductor) may be either green or bar e.
7 For direct wir e installations: ELECTRIC INST ALLA TION For power supply cord installations: Remove hold-down screw and terminal block cover . 1. Choose electrical connection type Power supply cord 4-wir e receptacle (NEMA T ype 14-30R). Go to “Power Supply Cord Connection.
8 Power supply cord strain r elief: 4-Wire Power Supply Cor d Connection P ower Supply Cord Connection 4-wire r eceptacle (NEMA type 14-30R) 4-prong plug Spade terminals with upturned ends Ring terminals IMPORT ANT : A 4-wire connection is requir ed for mobile homes and where local codes do not permit the use of 3-wir e connections.
9 3-wire r eceptacle (NEMA type 10-30R) 3-prong plug Spade terminals with upturned ends Ring terminals Use where local codes permit connecting cabinet-gr ound conductor to neutral wire. 3. Connect remaining wires 2. Connect neutral wire C B 4. Connect remaining wires 1.
10 4-Wire Dir ect Wire Connection Direct W ire Connection 1. Prepare your 4-wir e cable for direct connection 1" (25 mm) 3 1 ⁄ 2 " (89 mm) 5" (127 mm) 2. Prepare to connect neutral gr ound wire and neutral wir e E B A 1. Attach direct wire strain r elief C B A 2.
11 1. Prepare your 3-wir e cable for direct connection 1" (25 mm) 3½" (89 mm) 2. Remove center screw B 5. Connect remaining wires 4. Connect ground wire F A Use where local codes permit connecting cabinet-gr ound conductor to neutral wire. Remove center terminal block screw (B).
12 Connect neutral ground wir e (E) and neutral wire (white or center wire) (C) of power supply cor d or cable under center , terminal block screw (B). Tighten scr ew . Place ends of remaining wir es under outer terminal block screws. Tighten scr ews.
13 Louvered Hood Angled Hood Box Hood Exhaust hoods: Elbows: Recommended Styles: ■ 45° elbows provide better airow than 90° elbows. Clamps: ■ Use clamps to seal all joints. ■ Exhaust vent must not be connected or secured with scr ews or other fastening devices that extend into interior of duct and catch lint.
14 The “V ent System Charts” provide venting requir ements that will help achieve best drying performance. Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home.
15 Install V ent System 1. Install exhaust hood 12" min. (305 mm) 12" min. (305 mm) 2. Connect vent to exhaust hood Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood. V ent must t over the exhaust hood.
16 5. Attach long hose to dryer ll valve and tighten coupling Remove protective cap fr om water inlet valve. Attach other end of long hose to ll valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on ll valve connector .
17 2. Adjust leveling legs If dryer is not level, prop up using a wood block, use wr ench to adjust legs up or down, and check again for levelness. Once dryer is level, make sure all four legs ar e snug against the oor and dryer does not rock. LEVEL DRYER 1.
18 1. Remove door from dryer 2. Move the door strike Using a TORX ® T25 ® screwdriver , remove the 2 scr ews securing the door strike to the door frame of the dryer . Rotate the strike 180° and attach to the opposite side of dryer door frame, as shown.
19 4. Remove outer window assembly from trim ring Using a Phillips screwdriver , remove the 2 scr ews from the outer window retainer and r otate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with arrows in the gur e A above.
20 8. Reinstall hinge and latch on opposite sides Using a TORX ® T25 ® screwdriver , reinstall the latch plate, latch backing plate, and hinge assembly on the opposite sides from which they were r emoved.
21 9. Reinstall inner door assembly Position the door with the inside of the door facing up. Reinstall the 10 screws securing the inner door to the outer door . 10. Reinstall door on dryer Using a TORX ® T25 ® screwdriver , remove the 4 scr ews on the dryer .
22 3. Remove inner door from outer door Position the door with the inside of the door facing up. Using a Phillips screwdriver , remove the 10 scr ews securing the inner door to the outer door .
23 Reverse door swing square-shaped door 1. Remove door from dryer Using a TORX ® T25 ® screwdriver , remove the 4 scr ews securing the door hinge to the dryer and lift up and out to remove the door . Place the door on a soft towel or other non-scratch surface.
6. Reattach inner door to outer door Position the inner door on the outer door assembly . Using a Phillips screwdriver , secure with the 13 scr ews removed earlier . 7. Reattach door to dryer Using a TORX ® T25 ® screwdriver , reinstall the 4 scr ews securing the door hinge to the dryer .
An important point after buying a device Amana NED5700BW (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Amana NED5700BW yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Amana NED5700BW - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Amana NED5700BW you will learn all the available features of the product, as well as information on its operation. The information that you get Amana NED5700BW will certainly help you make a decision on the purchase.
If you already are a holder of Amana NED5700BW, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Amana NED5700BW.
However, one of the most important roles played by the user manual is to help in solving problems with Amana NED5700BW. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Amana NED5700BW along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center