Page 1 of the GE agp18 user manual — AGP18 AGV18
Page 1 · click to enlarge
Page 1

GE Appliances

Room Air Conditioners

Owner’s Manual & Installation Instructions

AGP18 AGV18

Pub. No. 49-7370 CG 1-98

Page 2 of the GE agp18 user manual — IF YOU NEED SERVICE
Page 2 · click to enlarge
Page 2
Safety InstructionsSafety Information Safety Precautions 3 Operating Instructions Controls 4, 5 Care and Cleaning 6 Installation Instructions Preparing to Install the Air Conditioner 7 Window Installation 8–12 Troubleshooting Tips Before You Call For Service 13 Normal Operating Sounds 13 Customer Service Warranty 15 Service Telephone Numbers Back Cover 2 Operating Instructions Installation Instructions Troubleshooting Tips Customer Service

Congratulations! You Are Now Part of the GE Family

Welcome to the GE family. We’re proud of our quality products and we are committed to providing dependable service. You’ll see it in this easy-to-use Owner’s Manual and you’ll hear it in the friendly voices of our customer service department.

GE agp18 — Congratulations! You Are Now Part of the GE Family diagram (page 2)
Fig. 1 · Congratulations! You Are Now Part of the GE Family

Best of all, you’ll experience these values each time you use your air conditioner. That’s important, because your new air conditioner will be part of your family for many years. And we hope you will be part of ours for a long time to come.

We thank you for buying GE. We appreciate your purchase, and hope you will continue to rely on us whenever you need quality appliances for your home.

GE & You, A Service Partnership.

IMPORTANT!

Fill out and return the Consumer Product Registration Card that is packed with this product.

FOR YOUR RECORDS

Write the model and serial numbers here:

#

#

You can find them on a label on the side of the air conditioner.

Staple sales slip or cancelled check here.

Proof of the original purchase date is needed to obtain service under the warranty.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.

You’ll find many answers to common problems in the Before You Call For Service section. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.

IF YOU NEED SERVICE

If you do need service, you can relax knowing help is only a phone call away. A list of toll-free customer service numbers is included in the back section. Or, you can always call the GE Answer Center® at 800.626.2000, 24 hours a day, 7 days a week.

Page 3 of the GE agp18 user manual — Read and follow this Safety Information carefully. SAVE THESE INSTRUCTIONS
Page 3 · click to enlarge
Page 3

SAFETY PRECAUTIONS

I This air conditioner must be properly

I Turn the mode control to OFF and unplug

installed in accordance with the Installation Instructions before it is used.

your air conditioner before making any repairs.

I Repair or replace immediately all electric

service cords that have become frayed or otherwise damaged.

Read and follow this Safety Information carefully. SAVE THESE INSTRUCTIONS

Page 4 of the GE agp18 user manual — Cooling Descriptions
Page 4 · click to enlarge
Page 4

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

About the controls on the air conditioner.

The controls will look like one of the following.

OFF

HIGH

HIGH COOL

FAN

LOW

MED COOL 1

FAN

LOW COOL

MODE CONTROL TEMP CONTROL

Controls

Mode Controls

Temp Controls

HIGH COOL, LOW COOL and MED COOL provide cooling with different fan speeds.

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating.

Cooling Descriptions

For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at midpoint.

For Maximum Cooling—Select HIGH COOL with the temp control at the highest number available on your knob.

For Quieter & Nighttime Cooling—Select LOW COOL with the temp control at midpoint.

Page 5 of the GE agp18 user manual — Controls
Page 5 · click to enlarge
Page 5
GE agp18 — Controls diagram (page 5)
Fig. 2 · Controls

The vent control is located above the control knobs.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, pull the lever toward you. To close it, push it in.

Fingertip pressure on the bank of horizontal louvers adjusts the air direction up or down.

For fixed side-to-side air direction, set the Circulaire switch to ON until the desired air direction is obtained, then move it to OFF.

For continuous side-to-side air circulation, set the Circulaire switch to ON and leave it there.

Page 6 of the GE agp18 user manual — Air Filter
Page 6 · click to enlarge
Page 6

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Open the inlet grille upward by pulling out the bottom of the inlet grille.

Using the tab, pull up slightly on the filter to release it and pull it down.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

Page 7 of the GE agp18 user manual — Tools You Will Need
Page 7 · click to enlarge
Page 7

Preparing to install the air conditioner.

Read these instructions completely and carefully.

Before You Begin

Do not change the plug on the power cord of this air conditioner.

IMPORTANT NOTES:

For personal safety, this air conditioner must be properly grounded.

Aluminum house wiring may present special problems—consult a qualified electrician.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

Follow National Electric Codes (NEC) and/or local codes and ordinances.

Electrical Requirements

We recommend that this model be installed on its own single branch circuit supplying 230/208-volt a.c., protected with a time delay fuse or circuit breaker.

This is recommended for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

Tools You Will Need

I Ruler or tape measure

I Scissors or knife

Show 5 more labels / short text on this page
I Phillips-head screwdriver · I Pencil · I Flat-blade screwdriver · I Level · I Hammer
Page 8 of the GE agp18 user manual — Preparing to Install the Air Conditioner
Page 8 · click to enlarge
Page 8
GE agp18 — Preparing to Install the Air Conditioner diagram (page 8)
Fig. 3 · Preparing to Install the Air Conditioner

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

Type B (7) Type C (5) Type D (2) Carriage Bolt (2) Lock Nut (4)

Page 9 of the GE agp18 user manual — WOOD PIECES—
Page 9 · click to enlarge
Page 9

Read completely, then follow step-by-step.

Window Requirements

IThese instructions are for a standard double-

hung window. You will need to modify them for other types of windows.

IThe air conditioner can be installed without the

accordion panels if needed to fit in a narrow window. See the window opening dimensions to the right.

18² min.

IAll supporting parts must be secured to firm

29² to 41² (With accordion panels)

wood, masonry or metal.

IThe electrical outlet must be within reach of the

power cord.

26² min. (Without accordion panels)

Window opening dimensions are for a standard double-hung window.

Storm Window Requirements

A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.

WOOD PIECES—

WIDTH: 2 ²

LENGTH: Long enough to fit inside the window frame.

1/ th2² higher an frame St frorm window ame

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2² higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Wood · Stool

Page 10 of the GE agp18 user manual — B
Page 10 · click to enlarge
Page 10

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

Window Installation Instructions

A 3

Remove the Air Conditioner From the Case

Remove the 2 shipping screws from the back of the case.

Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. C

Remove the 2 screws on each side of the case. Keep these for later use.

B

Prepare the Window and the Case

Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.

Remove the backing from the top mounting rail seal strip and attach the seal to the bottom of the top mounting rail.

A

D

Install the top mounting rail with 3 type A screws on the inside of the case. Insert the frames for the accordion panels into the top mounting rail and the frame guides. Attach the accordion panels to the side of the case using 5 type A screws.

B

Carefully insert the plastic frame guides into the bottom of the case on each side.

Show 5 more labels / short text on this page
Shipping screws · Top mounting rail · Bottom of case · Frame guide · Frame guides
Page 11 of the GE agp18 user manual — D
Page 11 · click to enlarge
Page 11

Open the window and mark the centerline of the window stool. Measure and mark 11² to the left and right of the centerline. B A 5

Prepare the Window

Loosely attach the sill brackets to the support brackets using the 2 carriage bolts and 2 lock nuts.

A 6

Install the Case in the Window

Align the inside edge of the sill brackets with the 11² mark from the centerline and attach them to the window sill using 2 type B screws on each side.

Secure the case to the window stool by using 3 type B screws.

E

Carefully place the case on the window stool aligning the center front on the bottom with the centerline marked on the window stool. Close the window making sure the window sash is behind the top mounting rail.

B

Using the larger diameter hole in the case, attach the brackets to the case using two type D screws and 2 lock nuts.

Pull the accordion panels to each window sash track. Attach them on each side to the window sash and the window stool using 4 type C screws.

F

Type D screws with nuts

Adjust the carriage bolts and the lock nuts in each support so that the case is installed with a slight downward tilt (about 1/8²). Tighten the bolts.

D

Show 8 more labels / short text on this page
Support bracket · Carriage bolt · Lock nut · 11² · Sill bracket · Centerline · Sill support · Type B screws
Page 12 of the GE agp18 user manual — B
Page 12 · click to enlarge
Page 12

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

Window Installation Instructions

B A 6

Install the Window Locking Bracket and the Foam Top Window Gasket

Attach the window locking bracket with a type C screw.

Cut the foam top window gasket to the window width.

Stuff the foam between the glass and the window to prevent air and insects from getting into the room. C

A 7

Install the Air Conditioner in the Case

Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case.

Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case. Push the grille in until it snaps into place.

B

Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown.

Lift the inlet grille and secure the front grille with a type A screw. Lower the inlet grille into place. D

Page 13 of the GE agp18 user manual — Normal Operating Sounds
Page 13 · click to enlarge
Page 13

Before you call for service…

Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service.

Problem Possible Causes What To Do

Air conditioner The air conditioner • Make sure the air conditioner plug is pushed does not start is unplugged. completely into the outlet.

The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.

Power failure. • If power failure occurs, turn the mode control to OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.

The temp control may • Turn the knob to a higher number. The highest setting not be set high enough. provides maximum cooling.

The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section.

The room may have been hot. • When the air conditioner is first turned on you need to allow time for the room to cool down.

Cold air is escaping. • Check for open furnace floor registers and cold air returns.

  • Set the air conditioner’s vent to the closed position.

Cooling coils have iced up. • See “Air conditioner freezing up” below.

Air conditioner Ice blocks the air flow • Set the mode control at HIGH FAN or HIGH COOL freezing up and stops the air conditioner with the temp at 1 or 2. from cooling the room.

Normal Operating Sounds

I You may hear a pinging noise caused by water

I Water will collect in the base pan during

being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

I The fan may run even when the compressor

I You may hear the thermostat click when the

is not.

compressor cycles on and off.

Page 14 of the GE agp18 user manual — Notes
Page 14 · click to enlarge
Page 14

Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions

Notes

Page 15 of the GE agp18 user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 15 · click to enlarge
Page 15

Air Conditioner Warranty

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. For service, call 800-GE-CARES.

For The Period Of: GE Will Replace, At No Charge To You:

One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, GE will also provide, free of charge, all labor original purchase and in-home service to replace the defective part.

Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this five-year warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.

What GE Will Not Cover:

IService trips to your home to teach you how to use the

IReplacement of house fuses or resetting of circuit

product.

breakers.

IImproper installation. If you have an installation problem,

IFailure due to corrosion on models not corrosion-

or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

protected.

IDamage to the product caused by improper power supply

voltage, accident, fire, floods or acts of God.

IIncidental or consequential damage to personal property

IFailure of the product resulting from modifications to the

caused by possible defects with this air conditioner.

product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

IIn commercial locations labor necessary to move the unit

to a location where it is accessible for service by an individual technician.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Page 16 of the GE agp18 user manual — Service Satisfaction
Page 16 · click to enlarge
Page 16

Operating Instructions Safety Instructions Installation Instructions Troubleshooting Tips Customer Service

Service Telephone Numbers.

GE Answer Center ® 800.626.2000

The GE Answer Center® is open 24 hours a day, 7 days a week.

In-Home Repair Service 800-GE-CARES (800-432-2737)

Expert GE repair service is only a phone call away.

Special Needs Service 800.626.2000

800-TDD-GEAC (800-833-4322)

GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons with limited mobility.

Service Contracts 800-626-2224

Purchase a GE service contract while your warranty is still in effect and you’ll receive a substantial discount. GE Consumer Service will still be there after your warranty expires.

Parts and Accessories 800-626-2002

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted).

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

Service Satisfaction

If you are not satisfied with the service you receive from GE:

First, contact the people who serviced your appliance.

Next, if you are still not pleased, write all the details—including your phone number—to:

Manager, Consumer Relations GE Appliances Appliance Park Louisville, KY 40225

Finally, if your problem is still not resolved, write:

Major Appliance Consumer Action Program 20 North Wacker Drive Chicago, IL 60606

Printed in Korea 16

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Air conditioner does not startThe air conditioner • Make sure the air conditioner plug is pushed is unplugged. completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker. Power failure. • If power failure occurs, turn the mode control to OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. p.13
Air conditioner does not cool as it shouldAirflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air conditioner. The temp control may • Turn the knob to a higher number. The highest setting not be set high enough. provides maximum cooling. The air filter is dirty. • Clean the filter at least every 30 days. See the Operating Instructions section. The room may have been hot. • When the air conditioner is first turned on you need to allow time for the room to cool down. Cold air is escaping. • Check for open furnace floor registers and cold air returns. • Set the air conditioner’s vent to the closed position. Cooling coils have iced up. • See “Air conditioner freezing up” below. p.13
Air conditioner freezing upIce blocks the air flow • Set the mode control at HIGH FAN or HIGH COOL and stops the air conditioner with the temp at 1 or 2. from cooling the room. p.13

Ask about the GE agp18

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE agp18

Be the first to ask — other owners or our team will answer.

Original document

GE agp18 manual PDF

16 pages·758 KB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…