EN
GE logo
Official user manual

GE Air Conditioner (10 ACA)

16 pages·543 KB·Air Conditioner·PDF·ENDEFRITNLJA
GE Air Conditioner (10 ACA)
Table of Contents 26 sections TABLE OF CONTENTS · Safety Information · Adapter Plugs · Connecting Electricity · … ShowHide
Page 4 of the GE Air Conditioner (10 ACA) user manual — READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS
Page 4 · click to enlarge
Page 4

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

WARNING!

USE OF EXTENSION CORDS– 115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

CAUTION:

DO NOT use an extension cord with any of the 230/208 volt models.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

USE OF ADAPTER PLUGS – 115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS

Page 5 of the GE Air Conditioner (10 ACA) user manual — Cooling/Heating Descriptions
Page 5 · click to enlarge
Page 5

About the controls on the air conditioner. www.GEAppliances.com

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

LOW

FAN HIGH

R

OFF

FAN

E

M

O

LOW COOL LOW HEAT

R

O

A

E

W

R

HIGH HEAT

HIGH COOL

OFF

LOW

LOW COOL

FAN

O

O

E

HIGH

HIGH COOL

R

FAN

MODE CONTROL TEMP CONTROL

Controls

Mode Control HIGH COOL and LOW COOL provide cooling with different fan speeds.

Temp Control The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to COOLER (blue) the indoor air will become cooler. Turn the knob to WARMER (red) and the indoor air will become warmer.

HIGH HEAT and LOW HEAT provide heating with different fan speeds.

LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating.

Heat Pump Models

When the outdoor temperature is lower than 25°F., heat is provided by the electric heater in the air conditioner instead of by the heat pump.

Cooling/Heating Descriptions

For Normal Cooling or Heating—Select HIGH COOL or HIGH HEAT with the thermostat at mid point.

For Maximum Cooling—Select HIGH COOL with the thermostat at maximum cool.

For Maximum Heating—Select HIGH HEAT with the thermostat at maximum heat.

For Quieter & Nighttime Cooling—Select LOW COOL with the thermostat at mid point.

Page 6 of the GE Air Conditioner (10 ACA) user manual — Air Direction
Page 6 · click to enlarge
Page 6

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

About the controls on the air conditioner.

Fan Switch

On Heat/Cool models, the fan switch lever is located in a hole through the control panel. To reach it, you need to remove the front grille. Use a small screwdriver to change the setting. Cool only models have a rocker switch on the front of the control box.

When set at CYCLE (down) the fan cycles on and off when cooling or heating. When set at CONT (continuous, up) the fan runs all the time. The unit is shipped in the CONT setting.

Temperature Limiting

Limiting the maximum and minimum settings prevents users from turning the control to the extreme heat or cool positions.

The normal range of the temp control is approximately 60°F to 85°F. The control range may be narrowed by the use of the temperature limiting screws located behind the control panel.

Each position equals approximately 3°F.

Vent Control

The vent control is located behind the front grille on the right side of the air discharge area. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open or close the vent: 1.Remove the front grille. 2.Remove and replace the vent card to the OPEN (mesh end toward the back) or to the CLOSE (mesh end toward the front) position.

Air Direction

Horizontal louvers on the front grille let you control the air direction up and down.

Remove the front grille to adjust the vertical louvers side-to-side to direct the air left or right.

Show 5 more labels / short text on this page
Limits · Limits cool temp · heat temp · Open · Close
Page 7 of the GE Air Conditioner (10 ACA) user manual — Front Grille
Page 7 · click to enlarge
Page 7

Care and cleaning of the air conditioner. www.GEAppliances.com

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.

Front Grille

The front grille can be removed for more thorough cleaning or to make the model and serial numbers accessible.

3. Pull the grille out from the bottom and lift up from the tabs on the top of the case.

To remove:

1. Pull the filter out. 2. Remove the two grille screws.

To replace:

Hook the tabs on the front grille even with the tabs on the case and snap into place.

Replace the screws and filter.

Show 6 more labels / short text on this page
Grille · Tab · On some models · On some models · Grille · Tab
Page 8 of the GE Air Conditioner (10 ACA) user manual — FRONT FRONT
Page 8 · click to enlarge
Page 8

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

Care and cleaning of the air conditioner.

To maintain optimum performance, clean the filter at least every 30 days.

Air Filter

To remove the air filter, on other models:

FRONT FRONT

Pull it down.

Dirty filter—Needs cleaning Clogged filter—Greatly reduces cooling, heating and airflow.

Turn the air conditioner off before cleaning.

The most important thing you can do to maintain the air conditioner is to clean the filter at least every 30 days. A clogged filter reduces cooling, heating and air flow.

To replace the air filter:

Replace the clean filter by pushing it back into place.

Keeping the air filter clean will:

IDecrease cost of operation.

ISave energy.

IPrevent clogged heat exchanger coils.

IReduce the risk of premature component

failure.

To clean the air filters:

IVacuum off the heavy soil.

IRun water through the filters.

IDry thoroughly before replacing.

To remove the air filter, on some models:

Carefully pull the tab forward, up and out.

Operating without the filter in place or with a damaged filter will allow dirt and dust to reach the indoor coil and reduce the cooling, heating, airflow and efficiency of the unit.

Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.

Page 9 of the GE Air Conditioner (10 ACA) user manual — Electrical Requirements
Page 9 · click to enlarge
Page 9

Preparing to install the air conditioner.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

Before You Begin

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

Follow National Electric Codes (NEC) and/or local codes and ordinances.

Electrical Requirements

Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Page 10 of the GE Air Conditioner (10 ACA) user manual — D
Page 10 · click to enlarge
Page 10

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

Installing a J-Model in an existing wall case.

IMPORTANT!

GE strongly recommends the removal of the old wall case and the installation of a new GE Wall Case. If you decide to keep the existing wall case, you may need a kit to ensure proper performance. If you DO NOT use a kit, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty.

J-Model Qualifying Questions

J-model air conditioners may fit in existing wall cases. However, they often need a kit to properly adapt the case to the GE air conditioner. Answer these questions and see the chart below for the proper kit.

A

What brand air conditioner will you be replacing?

B

What are the dimensions of the wall case currently in use?

What is the model number of the chassis currently in use? What is the model (or Type) number of the wall case currently in use?

Frequently, the J-model adapter kit will apply to another brand model “series” or specific vintage. In these cases, you need the chassis model number and/or the wall case or “type” number to confirm the use of the correct adapter kit.

D

What type of outdoor grille is used with the current wall case?

There may be an architectural grille attached to a wall case to enhance the exterior appearance of the building. Custom grilles may be used with J-model wall cases provided a J-model adapter kit is also used to ensure proper airflow.

Page 11 of the GE Air Conditioner (10 ACA) user manual — Use GE For: Description: Kit Number:
Page 11 · click to enlarge
Page 11

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

GE Kit Numbers

Use GE For: Description: Kit Number:

RAK56A100GE RAB13, 14 & 15 (ACLB & RCL Chassis)Fits all GE wall cases 26″W x 18″H x 24″D RAK107Hotpoint ACXB10 & 11 (ACTB Chassis)Adapts an older Hotpoint wall case to a “J” model chassis. Fits Hotpoint wall cases 253⁄4″W x 167⁄8″H x 185⁄8″D RAK108Whirlpool Type 23W Wall CaseAdapts Whirlpool wall case to a “J” model chassis. Fits Whirlpool wall cases 257⁄8″W x 161⁄2″H x 231⁄8″D RAK110GE RAB30 (“F” models)Adapts GE wall case to a “J” model chassis. Fits the RAB 30 wall case 26″W x 18″H x 24″D RAK123Fedders Wall Case “A”Adapts Fedders wall case to a “J” model chassis. Fits Fedders wall cases 27″W x 163⁄4″H x 163⁄4″D RAK126Westinghouse Wall Case (Type 2626D73H01)Adapts Westinghouse wall case to a “J” model chassis. Fits Westinghouse wall cases 257⁄8″W x 157⁄16″H x 16″D RAB46, 47 & 48Use these kits for all other brands not listed.Standard wall case for “J” model chassis. RAG13 stamped aluminum exterior grille included. Remove the existing case and replace. RAK690RAB36, 37, 38, 46, 47 or 48 (J-Chassis)If you attach a custom architectural outdoor grille, use this kit to ensure proper airflow. RAG14ERAB36, 37, 38, 46, 47 or 48 (J-Chassis)Architectural louvered exterior grille
Page 12 of the GE Air Conditioner (10 ACA) user manual — REMOVE SHIP PAD! REMOVE TAPE ON VENT LEVER!
Page 12 · click to enlarge
Page 12

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

structions complete Install the Air Condily and carefully. tioner in the Case. Ag plate on thefront

Attach the power cord to the base pan with the clamp.

E

Remove the shipping pad inside the air conditioner next to the compressor.

B

When the wall outlet is to the left, extend the cord under the unit and hold it in place with the clamp.

F

REMOVE SHIP PAD! REMOVE TAPE ON VENT LEVER!

Carefully slide the air conditioner back into the case. Make sure that the tubing on the unit does not touch the wall case and that the case installation is secure.

Attach the front grille. An opening for the power cord is on the bottom of the front grille. G

Show 9 more labels / short text on this page
Locking · plate · Remove · screw · Base pan · Power cord · Clamp · Remove shipping pad · Power cord Clamp
Page 13 of the GE Air Conditioner (10 ACA) user manual — Notes. www.GEAppliances.com
Page 13 · click to enlarge
Page 13

Notes. www.GEAppliances.com

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

Page 14 of the GE Air Conditioner (10 ACA) user manual — Normal Operating Sounds
Page 14 · click to enlarge
Page 14

Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions

Before You Call For Service…

Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service.

Problem Possible Causes What To Do

Air conditioner The air conditioner • Make sure the air conditioner plug is pushed completely does not start is unplugged. into the outlet.

The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace breaker is tripped. the fuse or reset the breaker.

Power failure. • If power failure occurs, turn the mode control to OFF. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture not cool as it should blocking the front of the air conditioner.

The temp control may not • Turn the knob to a warmer or cooler setting. The coolest be set high or low enough. setting provides maximum cooling. The warmest setting provides maximum heating on models with heat.

The air filter is dirty. • Clean the filter at least every 30 days. See the Care and cleaning of the air conditioner section.

The room may have been hot • When the air conditioner is first turned on you need to or cold. allow time for the room to cool down or warm up.

Cold air is escaping. • Check for open furnace floor registers and cold air returns.

  • Set the air conditioner’s vent to the closed position.

Cooling coils have iced up. • See “Air conditioner freezing up” below.

Air conditioner Ice blocks the air flow • Set the mode control at HIGH FAN or HIGH COOL freezing up and stops the air conditioner with the temp at a warmer setting. from cooling the room.

Normal Operating Sounds

I You may hear a pinging noise caused

I Water will collect in the base pan

by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

I The fan may run even when the

compressor is not.

I You may hear the thermostat click

when the compressor cycles on and off.

Page 15 of the GE Air Conditioner (10 ACA) user manual — Warrantor: General Electric Company. Louisville, KY 40225
Page 15 · click to enlarge
Page 15

Air Conditioner Warranty.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support

All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service, on-line, 24 hours a day, contact us at www.GEAppliances.com or call 800-GE-CARES.

Staple your receipt here. Proof of the original purchase date is needed to obtain service

under the warranty.

For The Period Of: GE Will Replace:

One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, GE will also provide, free of charge, all labor original purchase and in-home service to replace the defective part.

Five Years Any part of the sealed refrigerating system (the compressor, condenser, evaporator From the date of the and all connecting tubing) which fails due to a defect in materials or workmanship. original purchase During this additional four-year limited warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.

What GE Will Not Cover:

IService trips to your home to teach you how to use the

IReplacement of house fuses or resetting of circuit

product.

breakers.

IImproper installation. If you have an installation

IFailure due to corrosion on models not corrosion-

problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.

protected.

IDamage to the product caused by improper power

supply voltage, accident, fire, floods or acts of God.

IIncidental or consequential damage caused by possible

IFailure of the product resulting from modifications to

defects with this air conditioner.

the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.

IIn commercial locations labor necessary to move the

unit to a location where it is accessible for service by an individual technician.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

Page 16 of the GE Air Conditioner (10 ACA) user manual — Consumer Support
Page 16 · click to enlarge
Page 16

Consumer Support.

GE Air Conditioner (10 ACA) — Consumer Support diagram (page 16)
Fig. 1 · Consumer Support

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line. You can also “Ask Our Team of Experts™” your questions, and so much more...

GE Air Conditioner (10 ACA) — Consumer Support diagram (page 16)
Fig. 2 · Consumer Support

Expert GE repair service is only one step away from your door. Get on-line and schedule your service at your convenience 24 hours any day of the year! Or call 800-GE-CARES (800-432-2737) during normal business hours.

GE Air Conditioner (10 ACA) — Consumer Support diagram (page 16)
Fig. 3 · Consumer Support

GE supports the Universal Design concept—products, services and environments that can be used by people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call 800-TDD-GEAC (800-833-4322).

GE Air Conditioner (10 ACA) — Consumer Support diagram (page 16)
Fig. 4 · Consumer Support

Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime, or call 800-626-2224 during normal business hours. GE Consumer Home Services will still be there after your warranty expires.

GE Air Conditioner (10 ACA) — Consumer Support diagram (page 16)
Fig. 5 · Consumer Support

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at 800-626-2002 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

GE Air Conditioner (10 ACA) — Consumer Support diagram (page 16)
Fig. 6 · Consumer Support

If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations

GE Appliances, Appliance Park Louisville, KY 40225

GE Air Conditioner (10 ACA) — Consumer Support diagram (page 16)
Fig. 7 · Consumer Support

Register your new appliance on-line—at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material, or detach and use the form in this Owner’s Manual.

Printed in China

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GE Air Conditioner (10 ACA)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GE Air Conditioner (10 ACA)

Be the first to ask — other owners or our team will answer.

Original document

GE Air Conditioner (10 ACA) manual PDF

16 pages·543 KB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…