Who Should Use This Guidep.7How This Document is Organizedp.7Conventions Used in this Documentp.8Related Publicationsp.8Introductionp.9Front Panelp.10NetIron M2404C Front Panel Main Componentsp.11NetIron M2404F Front Panel Main Componentsp.11Unit LEDsp.12Port Status LEDsp.13NetIron M2404C Port Status LEDsp.13NetIron M2404F Port Status LEDsp.13NetIron M2404F Dual-Mode Port Status LEDsp.14Rear Panel – with AC Power-Supply Unitsp.15Panel Main Componentsp.15Rear Panel – with DC Power-supply Unitsp.16Panel Main Componentsp.16Power Supply Unitsp.16Blank Coversp.17Packing Listp.19Unpackingp.19Rack Mountingp.19Rack Mounting Specificationsp.20Ethernet Cablesp.21Console Interfacep.21DC Power installationp.21Grounding the Switchp.22Laser Safetyp.23Initial Configurationp.24Saving Configuration in a Text Filep.25Downloading Configuration from Backup Text Filep.26Reloading Factory Defaults Configurationp.26Monitoring/Configuring CPU Operating Temperaturep.26Temperature Management Commandsp.27Monitoring the Power Supplies Statusp.28BIST Test Results Reviewp.29Startup Execution of BISTp.30Software Image Naming Conventionsp.32Downloading a Software Image to the Switch Using TFTPp.32Preparing to Download an Image Using TFTPp.32Downloading a Device Software Image Using TFTPp.32Downloading a NI-M2404WebView Image Using TFTPp.34Software Upgrade via Ethernet Port (Outband)p.35Physical Specificationsp.37Dimensionsp.37Operating Conditionsp.37Management Featuresp.38Safety and Electromagnetic Compatibilityp.38Safetyp.38EMCp.38FCC 47 CFR: 2003 part 15 subpart B, class Ap.39CISPR 22 CLASS A Warningp.39VCCI (Japan) (Class A)p.39
Page 1 of the Foundry Networks M2404F user manual — Foundry NetIron M2404C and M2404F Metro Access Switches
Page 1 · click to enlarge
Page 1

Foundry NetIron M2404C and M2404F Metro Access Switches

Installation Guide

4980 Great America Parkway Santa Clara, CA 95054

Tel 408.207.1700

www.foundrynetworks.com

™ · January 2007

Page 2 of the Foundry Networks M2404F user manual
Page 2 · click to enlarge
Page 2

Copyright © 2007 Foundry Networks, Inc. All rights reserved. No part of this work may be reproduced in any form or by any means – graphic, electronic or mechanical, including photocopying, recording, taping or storage in an information retrieval system – without prior written permission of the copyright owner. The trademarks, logos and service marks ("Marks") displayed herein are the property of Foundry or other third parties. You are not permitted to use these Marks without the prior written consent of Foundry or such appropriate third party. Foundry Networks, BigIron, FastIron, IronView, JetCore, NetIron, ServerIron, TurboIron, IronWare, EdgeIron, IronPoint, the Iron family of marks and the Foundry Logo are trademarks or registered trademarks of Foundry Networks, Inc. in the United States and other countries.

Page 3 of the Foundry Networks M2404F user manual — WARNING
Page 3 · click to enlarge
Page 3

Safety Considerations

This equipment is for use in a restricted access area by qualified personnel only. To avoid electric shock, do not perform any servicing other than those contained in the unpacking instructions.

This equipment contains Electrostatic Discharge (ESD) sensitive components. Use ESD protection before servicing or installing components of this system.

CAUTION

Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

CAUTION

Remove the power cord from a power supply before you install it in or remove it from the device. Otherwise, the power supply or the device could be damaged as a result. (The device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source.)

CAUTION

All devices with DC power supplies are intended for installation in restricted access areas only. A restricted access area is where access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.

WARNING

The equipment is designed to be used with Class 1 Laser fiber optic transmitters which may endanger your eyes.

Do not look directly into the fiber optic cables or transmitter.

WARNING

HIGH VOLTAGE

Disconnect the product from the power line before removing the cover. Any adjustment and maintenance of the opened device should be done only while the device is disconnected from its source of power and should only be performed by qualified personnel, authorized by Foundry Networks.

January 2007 © 2007 Foundry Networks, Inc. ii

Page 4 of the Foundry Networks M2404F user manual — WARNING
Page 4 · click to enlarge
Page 4

WARNING

GROUNDING

Before connecting the product to the power line, make sure that the protective ground terminal of the device is connected to the safety ground conductor of the mains power cord.

The main power supply plug should only be inserted in a socket outlet provided with a connected safety ground. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding). Any interruption of the protective (grounding) conductor or disconnection of the protective ground terminal can make the device unsafe to use. Intentional interruption is prohibited.

This equipment has a connection between the earthed conductor of the DC supply circuit and the grounding conductor.

WARNING

WIRING FOR NATIONAL POWER PLUG

A mains power cable according to National Electrical Code (NEC) with molded IEC socket is supplied with each unit. The specific national mains power plug should be wired as follows:

  • Brown lead Live (phase)
  • Blue lead Neutral
  • Green/Yellow lead Safety ground.

WARNING

LINE VOLTAGE

Before connecting the product to the power line, make sure the voltage of the power source matches the requirements of the product, as marked on the label located near the power connectors.

WARNING

DC POWER SOURCE

The DC power source should be protected with a branch circuit over- current protection rated at 10Amp, located in the building installation

January 2007 © 2007 Foundry Networks, Inc. iii

Page 5 of the Foundry Networks M2404F user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

Who Should Use This Guidep.7How This Document is Organizedp.7Conventions Used in this Documentp.8Related Publicationsp.8Introductionp.9Front Panelp.10NetIron M2404C Front Panel Main Componentsp.11NetIron M2404F Front Panel Main Componentsp.11Unit LEDsp.12Port Status LEDsp.13NetIron M2404C Port Status LEDsp.13NetIron M2404F Port Status LEDsp.13NetIron M2404F Dual-Mode Port Status LEDsp.14Rear Panel – with AC Power-Supply Unitsp.15Panel Main Componentsp.15Rear Panel – with DC Power-supply Unitsp.16Panel Main Componentsp.16Power Supply Unitsp.16Blank Coversp.17Packing Listp.19Unpackingp.19Rack Mountingp.19Rack Mounting Specificationsp.20Ethernet Cablesp.21Console Interfacep.21DC Power installationp.21Grounding the Switchp.22Laser Safetyp.23Initial Configurationp.24Saving Configuration in a Text Filep.25Downloading Configuration from Backup Text Filep.26Reloading Factory Defaults Configurationp.26Monitoring/Configuring CPU Operating Temperaturep.26Temperature Management Commandsp.27Monitoring the Power Supplies Statusp.28BIST Test Results Reviewp.29Startup Execution of BISTp.30Software Image Naming Conventionsp.32Downloading a Software Image to the Switch Using TFTPp.32Preparing to Download an Image Using TFTPp.32Downloading a Device Software Image Using TFTPp.32Downloading a NI-M2404WebView Image Using TFTPp.34Software Upgrade via Ethernet Port (Outband)p.35Physical Specificationsp.37Dimensionsp.37Operating Conditionsp.37Management Featuresp.38Safety and Electromagnetic Compatibilityp.38Safetyp.38EMCp.38FCC 47 CFR: 2003 part 15 subpart B, class Ap.39CISPR 22 CLASS A Warningp.39VCCI (Japan) (Class A)p.39
Page 6 of the Foundry Networks M2404F user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

Who Should Use This Guidep.7How This Document is Organizedp.7Conventions Used in this Documentp.8Related Publicationsp.8Introductionp.9Front Panelp.10NetIron M2404C Front Panel Main Componentsp.11NetIron M2404F Front Panel Main Componentsp.11Unit LEDsp.12Port Status LEDsp.13NetIron M2404C Port Status LEDsp.13NetIron M2404F Port Status LEDsp.13NetIron M2404F Dual-Mode Port Status LEDsp.14Rear Panel – with AC Power-Supply Unitsp.15Panel Main Componentsp.15Rear Panel – with DC Power-supply Unitsp.16Panel Main Componentsp.16Power Supply Unitsp.16Blank Coversp.17Packing Listp.19Unpackingp.19Rack Mountingp.19Rack Mounting Specificationsp.20Ethernet Cablesp.21Console Interfacep.21DC Power installationp.21Grounding the Switchp.22Laser Safetyp.23Initial Configurationp.24Saving Configuration in a Text Filep.25Downloading Configuration from Backup Text Filep.26Reloading Factory Defaults Configurationp.26Monitoring/Configuring CPU Operating Temperaturep.26Temperature Management Commandsp.27Monitoring the Power Supplies Statusp.28BIST Test Results Reviewp.29Startup Execution of BISTp.30Software Image Naming Conventionsp.32Downloading a Software Image to the Switch Using TFTPp.32Preparing to Download an Image Using TFTPp.32Downloading a Device Software Image Using TFTPp.32Downloading a NI-M2404WebView Image Using TFTPp.34Software Upgrade via Ethernet Port (Outband)p.35Physical Specificationsp.37Dimensionsp.37Operating Conditionsp.37Management Featuresp.38Safety and Electromagnetic Compatibilityp.38Safetyp.38EMCp.38FCC 47 CFR: 2003 part 15 subpart B, class Ap.39CISPR 22 CLASS A Warningp.39VCCI (Japan) (Class A)p.39
Page 7 of the Foundry Networks M2404F user manual — How This Document is Organized
Page 7 · click to enlarge
Page 7

About This Document

Who Should Use This Guide

The procedures in this manual are for trained and qualified service personnel who are proficient with network switching and routing concepts. Installation, replacement and maintenance of the equipment described in this guide may only be done by trained and qualified service personnel.

How This Document is Organized

This document contains the following chapters.

1. About This Document The intended audience and the organization of this document, the conventions used in this document, and reference to related publications.
2. Overview An introductory description of the platform, a list of the product’s main features and a partial list of the management options implemented by the device software image that is installed on the platform.
3. Hardware Description The front components, including traffic ports, management ports and LEDs; The AC and DC power-supply options in the rear panel; base-board components and the hot-swappable power-supply units.
4. Installation and Setup Packing list, instructions for unpacking, rack-mounting, desktop installation, Ethernet cables, DC power installation safety precautions, grounding, and Laser safety.
5. Initial Configuration Using the Console

How to use the Command Line Interface (CLI) to configure the platform and monitor its temperature, the power source status and the status of the fans.

6. Built-In Self Test (BIST)

Set of basic built in tests performed automatically at startup and optionally by user’s request.

7. Software Download How to upgrade the software via the network.
8. Hot-swapping Modules

How to replace an access module or a redundant power-supply unit without interrupting operation.

9. Specifications Physical specifications, operating conditions and management features.

Chapter Contains

Page 8 of the Foundry Networks M2404F user manual — I MPORTANT N OTE
Page 8 · click to enlarge
Page 8

Conventions Used in this Document

This document uses the following formatting styles and conventions:

  • CLI syntax and coded examples are represented by mono-space characters and enclosed in rectangular frames. Under this category:

o Text issued by the device software is represented by regular characters.

o In command syntax specifications, text to be entered by the user is represented as follows:

Command names and keywords appear as bold upright characters.

Argument values (numeric or literal) that the user must supply are

represented by bold italic characters, enclosed in angle-brackets.

For example< a.b.c.d > represents an IP address, < 0-4094 > represents a

range of numerical values, and represents a character string.

o In coded examples, all text demonstrated as entered by the user appears in bold upright characters.

  • Command names and keywords in other text structures (especially in instruction steps) appear in bold characters.
  • Notes appear in bold characters and should never be ignored.

Related Publications

The software used for initial and network configuration of the device is described in the Software User Guide.

I MPORTANT N OTE

User Documentation for NetIron M2404 Software and the Java™-based graphical manager may be downloaded from the Foundry Website (www.foundrynetworks.com).

Page 9 of the Foundry Networks M2404F user manual — NOTE
Page 9 · click to enlarge
Page 9

Overview

Introduction

High powered networks require a combination of speed and robust services support to be able to provide the intensive and fluctuating demands of their end users. To answer these requirements, the network needs to provide data transmission at wire speed performance in a non-blocking fashion. This switch is an enhanced Metro Ethernet CPE platform designed to provide wire speed non-blocking Layer-2 and Layer-3 switching architecture as well as Hierarchical Virtual Private LAN Services (HVPLS) hubs-and-spokes and MPLS based rings support.

The platform capabilities include Ethernet LAN/ Line services, use of advanced Hierarchical QoS (tens of thousands of queues) as well as Hierarchical Virtual Private LAN Services (HVPLS) hubs-and-spokes and MPLS based rings support. The platform offers services convergence such as voice, data and video over Gigabit Ethernet, Enhanced Gigabit Ethernet (MPLS/ VPLS).

There are two flavors to the NetIron M2404, the NetIron M2404C and the NetIron M2404F.

(1) NetIron M2404C accommodates 24 Fast Ethernet copper ports and 4 Gigabit Ethernet ports;

(2) NetIron M2404F accommodates 24 Fast Ethernet fiber ports and 4 Gigabit Ethernet ports.

The platforms are identical in their performance.

NOTE

Throughout this guide, both switches are referred to as “NetIron M2404”, “the platform” or “the switch”, unless relating to a specific platform.

Foundry Networks M2404F — NOTE diagram (page 9)
Fig. 1
Foundry Networks M2404F — NOTE diagram (page 9)
Fig. 2
Figure 1NetIron M2404F
Foundry Networks M2404F — NOTE diagram (page 9)
Fig. 3
Foundry Networks M2404F — NOTE diagram (page 9)
Fig. 4
Figure 2NetIron M2404C
Page 10 of the Foundry Networks M2404F user manual — WARNING
Page 10 · click to enlarge
Page 10

Hardware Description

Front Panel

Enhanced GigE Ports 100baseX Ports GigE Ports

Switch Management Ports (Outband Port on

PSU LEDs Reset Button

top and Console Port on bottom)

Figure 3NetIron M2404F Platform Front Panel

Enhanced GigE Ports 10/100baseTX Ports GigE Ports

Foundry Networks M2404F — Hardware Description diagram (page 10)
Fig. 5 · Hardware Description

Switch Management Ports (Outband Port on

PSU LEDs Reset Button

top and Console Port on bottom)

Figure 4NetIron M2404C Platform Front Panel

To prepare for installation, make sure you have an ESD wrist strap that can be attached to a grounded metal surface. Put on the ESD wrist strap and ground yourself by attaching the clip end to a grounded metal surface (such as an equipment rack) to act as ground.

WARNING

For safety reasons, the ESD wrist strap should contain a series 1 meg ohm resistor.

To install an SFP transceiver into a port, do the following:

1. Put on the ESD wrist strap and ground yourself by attaching the clip end to a grounded metal surface (such as an equipment rack) to act as ground.
2. Remove the new module from its protective packaging.
Page 11 of the Foundry Networks M2404F user manual — NetIron M2404F Front Panel Main Components
Page 11 · click to enlarge
Page 11
3. Gently insert the SFP tranceiver into the port until the module clicks into place. The module is keyed to prevent incorrect insertion. See Figure 5 .

When inserting an SFP tranceiver into ports marked 27 or 28, verify that the SFP is facing upside -down (as shown in figure below). All other SFP ports on the switch face right-side up.

Foundry Networks M2404F — NetIron M2404C Front Panel Main Components diagram (page 11)
Fig. 6 · NetIron M2404C Front Panel Main Components
Foundry Networks M2404F — NetIron M2404C Front Panel Main Components diagram (page 11)
Fig. 7 · NetIron M2404C Front Panel Main Components
Foundry Networks M2404F — NetIron M2404C Front Panel Main Components diagram (page 11)
Fig. 8 · NetIron M2404C Front Panel Main Components
Figure 5Inserting an SFP, upside-down, into the Enhanced GigE Slot

NetIron M2404C Front Panel Main Components

For NetIron M2404C: 10/100baseTX Ports 24 RJ-45 sockets with 10/100 Mbps LAN speed auto sensing, marked 1 to 24.

GigE Dual-Mode Ports Two dual-mode1000baseX interface (SFP) or 10/100/1000BaseT (RJ45) marked 25 and 26.

Enhanced GigE Ports Two 1000baseX interface (SFP) marked 27 and 28. Please note that the SFP transceivers are inserted into the slot, belly-down, as shown in figure above.

RJ45 socket for CLI configuration and management of the unit.

RJ45 socket with 10/100 Mbps LAN speed auto sensing for out- of-band Ethernet management and software update.

RST Button Reset button. To avoid accidental activation, the button is recessed behind the panel. Press with a pin or a similar narrow object.

NetIron M2404F Front Panel Main Components

For NetIron M2404F: 100baseX Ports 24 SFP sockets marked 1 to 24.

Show 4 more labels / short text on this page
Component Description · Console Management Port · Ethernet Management Port · Component Description
Page 12 of the Foundry Networks M2404F user manual — Unit LEDs
Page 12 · click to enlarge
Page 12

GigE Dual-Mode Ports Two dual-mode1000baseX interface (SFP) or 10/100/1000BaseT (RJ45) marked 25 and 26.

Enhanced GigE Ports Two 1000baseX interface (SFP) marked 27 and 28. Please note that the SFP transceivers are inserted into the slot, belly-down, as shown in figure above.

RJ45 socket for CLI configuration and management of the unit.

RJ45 socket with 10/100 Mbps LAN speed auto sensing for out- of-band Ethernet management and software update.

RST Button Reset button. To avoid accidental activation, the button is recessed behind the panel. Press with a pin or a similar narrow object.

Unit LEDs

The following descibes the LEDs on the chassis.

  • Off – Link down.

ETH Ethernet management interface status.

  • Green – Link up.
  • Blinking green – activity.

FLT Platform HW fault. • Off – Switch hardware OK.

  • Red – CPU can't boot.
  • Blinking red – Failure during BIST.
  • Off – No management activity.

MNG CPU controller is processing management tasks.

  • Green – Management activity.

STS General platform status. • Off – Platform processing boot loader.

  • Green fast blink – Platform initializing application.
  • Green – Normal operation.

PSU #1 PSU #1 status. • Green – PS #1 functioning.

  • Red – Problem in PS #1 or no power feed.
  • Off – PS #1 removed.

PSU #2 PSU #2 status. • Green – PS #2 functioning.

  • Red – Problem in PS #2 or no power feed.
  • Off – PS #2 removed.
Show 4 more labels / short text on this page
Component Description · Console Management Port · Ethernet Management Port · Label Function Indication
Page 13 of the Foundry Networks M2404F user manual — NetIron M2404F Port Status LEDs
Page 13 · click to enlarge
Page 13

Port Status LEDs

A status LED is associated with each port.

NetIron M2404C Port Status LEDs

Foundry Networks M2404F — NetIron M2404C Port Status LEDs diagram (page 13)
Fig. 9 · NetIron M2404C Port Status LEDs

Port 3 Port 5 Port 7 Port 9 Port 11

Port 2 Port 4 Port 10 Port 6 Port 8

Figure 6Location of NetIron M2404C Port Status LEDs

The port status LEDs (1 to 24) for NetIron M2404C are situated on the upper row of ports. The LED on the left side of each upper port is associated with that port. The LED on the right side of each upper port is associated with the port underneath that port.

NetIron M2404F Port Status LEDs

Foundry Networks M2404F — NetIron M2404F Port Status LEDs diagram (page 13)
Fig. 10 · NetIron M2404F Port Status LEDs

Port 13 Port 15 Port 17 Port 19

Port 21 Port 23

Port 14 Port 16 Port 18 Port 20 Port 22

Figure 7Location of NetIron M2404C Port Status LEDs

The port status LEDs (1 to 24) for NetIron M2404F are situated below each SFP.

Show 7 more labels / short text on this page
Port Status Indication · Link Green · Activity Blinking green · Fault/disabled Amber · Port 1 · Port 12 · Port 24
Page 14 of the Foundry Networks M2404F user manual — SFP Indicators
Page 14 · click to enlarge
Page 14

NetIron M2404F Dual-Mode Port Status LEDs

Foundry Networks M2404F — NetIron M2404F Dual-Mode Port Status LEDs diagram (page 14)
Fig. 11 · NetIron M2404F Dual-Mode Port Status LEDs
Figure 8Location of NetIron M2404F Dual-Mode Port Status LEDs

Dual-mode port status LEDs are associated with dual-mode RJ45/SFP GiGE ports 25 and 26.

RJ-45 Indicators

RJ45 Dual-Mode Port Status Indication

Link/Activity Left LED is Green

Disabled Right LED is Amber

SFP Indicators

SFP Dual-Mode Port Status Indication

Link Green · Activity Blinking green · Disabled Amber

Page 15 of the Foundry Networks M2404F user manual — Panel Main Components
Page 15 · click to enlarge
Page 15

Rear Panel – with AC Power-Supply Units

Hot-swappable PSU #2 Fan apertures

Foundry Networks M2404F — Rear Panel – with AC Power-Supply Units diagram (page 15)
Fig. 12 · Rear Panel – with AC Power-Supply Units

Grounding studs On-off switch

Figure 9Rear Pane l with AC PSUs

Panel Main Components

Two AC Power supplies As specified in Power Supply Units.

Two grounding posts Designed for a UL-listed two-hole long-barrel 5/8 10 AWG compression lug. Burndy YAZV10-2TC14 or an equivalent is recommended.

Show 6 more labels / short text on this page
Hot-swappable PSU #1 · On-off switch · AC-Power · AC-Power · inlet · inlet
Page 16 of the Foundry Networks M2404F user manual — Power Supply Units
Page 16 · click to enlarge
Page 16

Rear Panel – with DC Power-supply Units

Hot-swappable PSU #2 Fan apertures

Foundry Networks M2404F — Rear Panel – with DC Power-supply Units diagram (page 16)
Fig. 13 · Rear Panel – with DC Power-supply Units

PWR and Invert. Con.

PWR and Invert. Con.

LEDs Figure 10Rear Panel with DC PSUs

Panel Main Components

Two DC Power supplies As specified in Power Supply Units.

Two grounding posts Designed for a UL-listed two-hole long-barrel 5/8 10 AWG compression lug. Burndy YAZV10-2TC14 or an equivalent is recommended.

Power Supply Units

Power is fed to the platform via two redundant hot-swappable power supply units (PSUs). The following PSU versions are available:

ACPS Dual-range AC power supply:

100-120 VAC@ 5A or 200-240VAC@ 2.5A 50/60 Hz

DCPS DC power supply:

-48VDC Nominal @ 3A (minimum-36V ; maximum -72VDC)
Foundry Networks M2404F — Power Supply Units diagram (page 16)
Fig. 14 · Power Supply Units
Figure 11AC Power Supply Unit
Show 6 more labels / short text on this page
Hot-swappable PSU #1 · Terminal · Grounding studs Terminal · block · block · LEDs
Page 17 of the Foundry Networks M2404F user manual — Blank Covers
Page 17 · click to enlarge
Page 17
Foundry Networks M2404F — Blank Covers diagram (page 17)
Fig. 15 · Blank Covers

DC power-supply terminals:

LEDs:

-48V/3A GND +BAT.RET

INVERT CON. PWR

Figure 12DC Power Supply Unit

The DC power supply panel has the following components:

Input terminals:

-48V/3A Negative DC input terminal

GND Ground terminal internally connected to the platform’s ground line

+BAT.RET Positive DC input terminal

NOTE

Neither the +BAT.RET nor the -48VDC is connected to the GND terminal. If required, this can be performed externally by the user.

LEDs:

PWR Glows green when power is on

INVERT CON. Glows red to indicate inverted DC polarity

Blank Covers

To avoid overheating of the components by improper air-flow, always keep empty slots covered. Use the panel screws on the supplied blank faceplates and blank filler to fasten the blanks to the appropriate empty slots.

Page 18 of the Foundry Networks M2404F user manual — Blank Covers
Page 18 · click to enlarge
Page 18
Foundry Networks M2404F — Blank Covers diagram (page 18)
Fig. 16 · Blank Covers

Figure 13 Blank Filler for Empty Power-Supply Slot

Page 19 of the Foundry Networks M2404F user manual — Rack Mounting
Page 19 · click to enlarge
Page 19

Installation and Setup

This section provides installation and setup instructions. The platform can be installed in a standard 19-inch rack or as a standalone unit in a desktop configuration.

Packing List

The shipping package includes the following items:

  • NetIron M2404F /NetIron M2404C platform.
  • One AC ( ACPS ) or DC ( DCPS ) power-supply unit, installed.
  • One power cable.
  • Two rack-mounting brackets with screws
  • Console cable
  • 1 Blank PSU filler
  • Documentation CD

WARNING

If the installation requires a power cord other than the one supplied with the device, make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device.

Unpacking

The platform is factory tested and inspected prior to shipment. In case of damage to the unit during shipment, contact your local dealer.

It is recommended that you keep the shipping package until the unit has been installed and verified as operational. The platform, like all electronic devices with static sensitive components, should be handled with care.

Rack Mounting

The supplied mounting brackets can be attached to the sides of the chassis either flush with the front panel (flush-mounting) or midway between the front and rear panels (mid-mounting). Use the supplied screws to fasten the mounting brackets to the chassis in the required position (flush or mid-mounting).

Before mounting any equipment onto the rack, make sure that there is generous clearance behind the rack for proper ventilation and for easy access to the rear components. Do not place objects that might obstruct airflow behind the chassis.

Page 20 of the Foundry Networks M2404F user manual — Rack Mounting Specifications
Page 20 · click to enlarge
Page 20

WARNING

Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over.

Rack Mounting Specifications

Width Basic body440 mm (17.4”) Overall, including brackets: 483 mm (19”)

Height 44 mm (1.73”) = 1 RU

Depth 414 mm (16.3”)

Distance between mounting holes Horizontal: 465 mm (18.3”) Vertical: 31.75 mm (1.25”) Vertical separation: 12.7 mm (0.5”)

Foundry Networks M2404F — Rack Mounting Specifications diagram (page 20)
Fig. 17 · Rack Mounting Specifications
Figure 14Dimensions in mm for Rack-mounting
Page 21 of the Foundry Networks M2404F user manual — DC Power installation
Page 21 · click to enlarge
Page 21

Ethernet Cables

When connecting an RJ-45/RJ-48 port to an end station, workstation or server, use a standard RJ-45/RJ-48 pin-out cable.

Console Interface

A simple menu-driven interface provides for system initialization and diagnostics. The Console interface is EIA232 VT-100 compatible. The primary purpose of the terminal interface is to set basic operational parameters.

The terminal interface is password protected. By default there is no password set for the terminal interface.

Using the enclosed serial cable (see table below for wiring), connect the RJ-45 connector to the connector marked “Console” and the other side to the 9-pin serial port connector on the back of your PC.

The supplied cable has the following pinout:

Switch Side PC Side

RJ-45 Pin # DB-9 Female

NOTE

You can also use a RJ-45/DB-9 cable.

DC Power installation

The DC supply source is to be located within the same premises as this equipment. The DC power source should be protected with a circuit breaker with a rating of 10Amp as disconnect device, connected to the non-grounding conductor. The unit shall be connected directly to the DC supply system; there shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the point of connection of the grounding electrode conductor.

This equipment shall be located in the same immediate area (such as, adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the grounding conductor, and also the point of grounding of the DC system. The DC system shall not be earthed elsewhere.

Page 22 of the Foundry Networks M2404F user manual — 10 AWG
Page 22 · click to enlarge
Page 22

For each DC power block a set of a minimum 2x18AWG cables shall be used with suitable end terminal legs matching the conductor’s gauge. Use a RED lead to for the positive conductor and a BLACK lead for the negative conductor. It is recommended that only UL listed components be used for the DC power connections.

CAUTION

For a DC system, use a grounding wire of at least 10 American Wire Gauge (AWG). The 10 AWG wire should be attached to an agency- approved crimp connector, crimped with the proper tool. The crimp connector should allow for securement to both ground screws on the enclosure.

CAUTION

For the DC input circuit to the system, make sure there is a Listed 10 amp circuit, minimum -48Vdc, double pole, on the input to the terminal block. The input wiring for connection to the product should be Listed copper wire, 18 AWG, marked VW-1, and rated minimum 90 deg. C.

NOTE

There is no connection needed for GND. Only the ground wire is connected to the Grounding Stud.

Grounding the Switch

WARNING

Before connecting power to the switch, make sure that both grounding posts in the rear panel are firmly connected to a reliable ground through a #10 AWG grounding wire terminated by a UL-listed two-hole long-barrel 5/8 10 AWG compression lug with hole size and spacing as shown in Figure 15 below.

The Burndy YAZV10-2TC14 or an equivalent UL-listed two-hole compression lug is recommended.

Foundry Networks M2404F — WARNING diagram (page 22)
Fig. 18

φ6.4 mm

10 AWG

Figure 15Compression Grounding Lug

To connect the switch to the ground, proceed as follows:

1. Prepare a minimum #10 AWG grounding wire terminated by a crimped two-hole lug with hole diameter and spacing as shown in Figure 15 . Use a suitable crimping tool to fasten the lug securely to the wire. Adhere to your company’s policy as to the wire gauge and the number of crimps on the lug.

16 mm (5/8”) · (1/4”)

Page 23 of the Foundry Networks M2404F user manual — Laser Safety
Page 23 · click to enlarge
Page 23
2. Remove the bolts and spring-washers from the grounding posts on the switch’s rear panel, and clean the metal surface underneath with a dry cloth if necessary.
3. Apply some anti-oxidant onto the metal surface.
4. Mount the lug on the two grounding posts, replace the spring-washers and fasten the bolts. Avoid using excessive torque.
5. Connect the grounding wire to a reliable ground. If the switch is mounted in a rack, use a common ground for all devices on the rack, according to your company’s policy.

Laser Safety

The device is provided with SFP sockets in which fiber optic transceivers may be installed. In order to meet the safety requirement of Class 1 fiber optic laser emission levels, only fiber optic transceivers which comply with IEC 60825-1 or IEC 60825-2 and FDA 21 CFR 1040.10 and CFR 1040.1 must be used.

Page 24 of the Foundry Networks M2404F user manual — NOTE
Page 24 · click to enlarge
Page 24

Initial Configuration Using the Console

Initial Configuration

The Configuration command-language interface (CLI) is accessed by using a VT-100 (or compatible terminal) to the console port of the switch. The terminal port parameters are fixed at: 9600 bps, 8 data bits, 1 stop bit, no parity and without flow control. This provides a convenient method for initial setup of the switch. System parameters are stored in a non-volatile memory. They need to be set up only during the initial setup or when the system has been reset to the factory defaults.

The following keys are used to access the menu:

Enter Ends an input line

Backspace Clears last character in input mode

Tab Auto-Completes a command

A screen similar to the following example appears on the Console Port at power up or reset:

//////////////////////////////////////////////////////////////////// // // Foundry Networks // // Switch model : NETIRON M2404F // SW version : 2.0.00 created January 12 2007 - 21:35:37 /////////////////////////////////////////////////////////////////// User Access Verification Password:

There is no default password, press for password.

NOTE

You can configure the password later.

Type ? to display the available commands:

device-name>? alias An alias of a command dir List files in flash. display Display file. enable Turn on privileged mode command exit Exit current mode and down to previous mode help Description of the interactive help system ls List files in flash. no Negate a command or set to defaults

Page 25 of the Foundry Networks M2404F user manual — Saving Configuration in a Text File
Page 25 · click to enlarge
Page 25

quit Disconnect and logout show Show running system information terminal Terminal configuration setup who Display who is on vty

To continue initial configuration procedure perform the following steps:

1. Enter privileged (Enable) mode. Type the command: enable .
2. Enter configure mode. Type the command: configure terminal .
3. Set the switch IP address: Type the command : ip address < aa.bb.cc.dd/yy >, where < aa.bb.cc.dd > is the IP address assigned to the switch and yy is the number of bits in the netmask (e.g. netmask of 255.255.255.0 would be /24 ).
4. Set the default gateway IP address if the host is on a different subnet: Type the command : ip route 0.0.0.0/0 < aa.bb.cc.dd > where < aa.bb.cc.dd > is the IP address of the default gateway.
5. Return to privileged (Enable) mode: Type the command: end .
6. To verify if the IP addresses were set correctly, type: show ip.

Example:

device-name # show ip IP-ADDR100.100.100.1 NET-MASK : 255.255.255.0

NOTE

The show command can be used to display a variety of parameters: Setup Configuration and others. To view the show command options type: show ?

7. Type the command: write from privileged (Enable) mode.

At this point the Initial configuration setup is completed and the switch can be accessed using Ping or Telnet commands.

Saving Configuration in a Text File

A variety of TFTP Server programs can be used by the host computer where the software images and configuration files are located. The only information that is required by the TFTP Server is the location of the file on the host computer’s file system.

It is recommended that the configuration be saved in an external text backup file. To write the backup configuration file, use the command copy.

To view the copy command options type: copy ?

device-name#copy ? FILE-NAME Source file. Format: [[device/]path]file-name device: flash: - local file system tftp://A.B.C.D - TFTP server Example: tftp://1.1.1.1/directory/filename.bin

Page 26 of the Foundry Networks M2404F user manual — Monitoring/Configuring CPU Operating Temperature
Page 26 · click to enlarge
Page 26

application Application downloading image java Java downloading image running-config Copy running config... startup-config Startup configuration data

To write the backup configuration file, type:

device-name#copy startup-config

is the file where the configuration file was saved.

Downloading Configuration from Backup Text File

The configuration file can be easily downloaded, using the copy command. Type:

copy tftp:/// startup-config

is the file where the configuration file was saved.

NOTE

The copy command uses TFTP protocol for its execution, so prior to using the copy command, verify that the TFTP Server program is executed by the addressed computer.

Reloading Factory Defaults Configuration

Use the reload command to reload the factory defaults configuration.

device-name#reload to-defaults

Restore factory setting and Reboot the Switch !

[y/n]y

Rebooting ...

NOTE

The reload to-defaults command does NOT change the IP address and netmask of the switch.

Monitoring/Configuring CPU Operating Temperature

Should the temperature reach the configured upper limit, the unit will send an SNMP trap to the management station. If this occurs, the user is requested to make sure that all unit ventilation airways are free and disengaged and that the fans are functioning.

Page 27 of the Foundry Networks M2404F user manual — Temperature Management Commands
Page 27 · click to enlarge
Page 27

Temperature Management Commands

Viewing the Status:

device-name#show temperature

CPU Temperature = 28C / 82F

device-name#show temperature high-limit CPU Temperature high limit = 20C / 68F

Configuring Temperature Management Parameters:

device-name#configure terminal

device-name(config)#monitor temperature

device-name(config monitor temperature C)#limit NUMBER Value of limit for alerting current test

device-name(config monitor temperature C)#limit 70

Viewing the Temperature Setting from a Running Configuration:

device-name#show running-config Building the configuration ... ! Current Configuration: ! ! Version 2.0 ! password a1FhfHKwXHFlU ip address 10.4.1.5 255.255.0.0 ! ! Switch Monitoring configuration: ! monitor temperature enable limit 70 !

Restoring the Default Value:

device-name#configure terminal

device-name(config)#monitor temperature

device-name(config monitor temperature C)#default

Page 28 of the Foundry Networks M2404F user manual — Monitoring the Power Supplies Status
Page 28 · click to enlarge
Page 28

Monitoring the Power Supplies Status

Viewing the status during system boot:

BUILT-IN SELF TEST CPU Core Test : Passed CPU Interface Test : Passed Data Buffer Test : Passed Power Supply Test : Passed On-board Power Test : Passed Fan Test : Passed

Viewing the status during operation:

The Power Supply status is available on the DC and dual-feed AC models only. The possible values are OK, Failed, and Not Installed.

device-name#show power-supply Power supply 1 : OK Power supply fan 1 : OK

Page 29 of the Foundry Networks M2404F user manual — BIST Test Results Review
Page 29 · click to enlarge
Page 29

Built-In Self Test (BIST)

The BIST performs a set of basic hardware and configuration validity tests. Tests in the BIST are sorted into several groups – for example, the tests of the Power Supply units belong to a Power Supply Test group.

Startup BIST - The BIST is performed automatically on startup. The results are summarized on the terminal before the switch banner.

BIST by request - A user may request BIST execution at any time by using a CLI command.

The current BIST status may be read and cleared by using CLI commands. When the BIST detects a failure in any of the tests, it causes the Status LED indicator to blink.

The switch supports the following tests:

  • CPU Core Test
  • CPU Interface Test
  • Data Buffer Test
  • Power Supply Test
  • On-Board Power Test
  • Fan Test
  • Temperature Test.

Table 1 describes the tests.

Table 1Description of the Built-in Tests

CPU Core Test Checks CPU block integrity

CPU Interface Test Checks the existence of the UART (register write/read operation). Both COM1 and COM2 are checked.

Data Buffer Test Checks the integrity of NVRAM database.

Power Supply Test Checks the existence and status of the DC power supplies. If both DC power supplies are connected, the test will result with Passed. When one of the DC power supply is disconnected, the test will result with Failed.

Fan Test Checks the status of the 3 fans.

On-Board Power Test Checks the 5 On-Board Power levels: 3.2V, 2.5V, 1.8V, 1.5V and

Temperature Test Validates temperature ranges inside the device and tests temperature sensors.

BIST Test Results Review

If any of the BIST tests fail, the FLT LED starts blinking. To display BIST results, perform the following steps:

1. Connect a terminal cable to Console port.

Test Description

Page 30 of the Foundry Networks M2404F user manual — Startup Execution of BIST
Page 30 · click to enlarge
Page 30
2. Re-power the unit, if required.
3. Use the show self-test command in Privileged (Enable) mode. If you prefer to display all BIST results, use the show self-test full command instead.

To invoke a BIST by Request at any time while the switch is running, use the self-test command in Privileged (Enable) mode.

The switch will automatically start up in debug mode when one of the five On-Board power levels deviates by 2% above or below the required level. See the explanation below.

Startup Execution of BIST

The startup BIST reports a summary of the results by BIST group. If all tests of the group pass, Passed is displayed for all groups.

Press any key to stop auto-boot... 0 auto-booting... Uncompressing 4329228 bytes... Loading image... 17671392 Init TFFS BUILT-IN SELF TEST CPU Core Test : Passed CPU Interface Test : Passed Data Buffer Test : Passed Power Supply Test : Passed On-board Power Test : Passed Fan Test : Passed

If any test in the group except the On-Board Power fails, Failed is displayed for the entire group and the switch starts normally. In such cases, the switch starts in debug mode (switching disabled and the switch is running with the default configuration). If one of the On-Board Power level checks fails, the switch will not initialize the ports and will start in a special debug mode, as shown below:

Press any key to stop auto-boot... 0 auto-booting... Uncompressing 4329228 bytes... Loading image... 17671392 Init TFFS BUILT-IN SELF TEST CPU Core Test : Passed CPU Interface Test : Passed Data Buffer Test : Passed Power Supply Test : Passed On-board Power Test : Passed Fan Test : Passed

Page 31 of the Foundry Networks M2404F user manual — Startup Execution of BIST
Page 31 · click to enlarge
Page 31

//////////////////////////////////////////////////////////////////// FOUNDRY NETWORKS // Switch model : FOUNDRY NETWORKS NETIRON M2404F 256M // // SW version : 2.0.00 created January 15 2007 - 21:35:37 //////////////////////////////////////////////////////////////////// User Access Verification Password: device-name>

In this case, you can enter into Enable mode as usual, and examine the detailed Self-Test results.

For example:

device-name#self-test Processing BIST by request... CPU Core Test : CPU Validation - Passed CPU Interface Test : UART Existence - Passed Data Buffer Test : Application Image Validity - Passed Java Agent Image Validity - Passed PROM Device Access Validity - Passed Power Supply Test : Power Supply 1 - Passed Power Supply Fan 1 - Passed Power Supply 2 - Not installed Power Supply Fan 2 - Not installed On-board Power Test : On-board Power 3.3V - Passed On-board Power 2.5V - Passed On-board Power 1.8V - Passed On-board Power 1.25V - Passed Fan Test : Fan 1 - Passed Fan 2 - Passed Fan 3 - Passed Temperature Test : Temperature - Passed

Page 32 of the Foundry Networks M2404F user manual — Downloading a Device Software Image Using TFTP
Page 32 · click to enlarge
Page 32

Software Download

The executable software image contained on the platform can be upgraded via the network whenever new versions become available, reflecting changes in the MIBs or enhancements to the software. The software is stored in erasable Flash memory. It must be downloaded using the Trivial File Transfer Protocol (TFTP).

Software Image Naming Conventions

Table 2 displays an example of typical software image names.

NOTE

The image name is a typical example. The numbers in the name are illustrative and should not be regarded as the latest released version numbers.

Table 2Typical Software Image Filename Example

Typical Application Image Name Typical NI-M2404WebView Image Name

NetIron 2404 v2.0.00.bin NI-M2404WebViewL3-V3.6.8.img

Downloading a Software Image to the Switch Using TFTP

Preparing to Download an Image Using TFTP

Before you begin to download a software image using TFTP, take the following precautions:

  • Ensure that the workstation acting as TFTP server is configured properly.
  • Ensure that the switch has a route to the TFTP server. The switch and the TFTP server must be in the same subnet if you do not have a router to route traffic between subnets. Use the ping command to check connectivity to the TFTP server.
  • Ensure that the software image to be downloaded is in the correct directory on the TFTP server.
  • Ensure that the permissions on the file are set correctly. Permissions on the file should be at least read for the specific username.
  • A power outage (or other problem) during the download procedure can corrupt the Flash code. If the Flash code is corrupted, you can connect to the switch through the console port and download the application in the Loader by using the download application command.

Downloading a Device Software Image Using TFTP

To download a device software image to the switch from a TFTP server, proceed as follows:

Page 33 of the Foundry Networks M2404F user manual — NOTE
Page 33 · click to enlarge
Page 33
1. Copy the device software image file to the appropriate TFTP directory on the workstation.
2. Log into the switch through the console port or through a Telnet session. If you log in using Telnet, your Telnet session will disconnect when you reset the switch to run the new software.
3. Make sure there is enough free space on the device file system. Use “dir” command for this. Free disk space should be at least 0.5MB larger then the downloaded application size.

Example:

device-name#dir Listing Directory flash:/: d S 2048 Jun 30 2005 17:56 Boot/ d S 2048 Jan 1 1993 00:04 Etc/ d S 2048 Jun 14 2005 12:01 Java/ d S 2048 Jan 1 1980 00:00 Log/ d S 2048 Jul 5 2005 21:36 Usr/ d SH 2048 Jan 1 1980 00:00 Hidden/ - 260 Jan 1 1993 00:00 profile.cfg - 43796 Jul 5 2005 21:26 dflt_startup_bin.cfg - 5382 Jul 5 2005 21:26 dflt_startup.cfg Free disk space 5655104

4. If there is not enough free space, delete unnecessary files. This is done by using “del” command.

device-name#del <filename>

Example:

device-name#del /Boot/Oldimage.bin

5. Download the device software image from the TFTP server using the copy application command in Privileged (Enable) mode:

device-name#copy application <TFTP URL> [<destination file name>]

Example:

device-name#copy application tftp://192.192.54.10/M2404Cv2.0.bin

NOTE

The switch remains operational while the image is downloaded.

The application is downloaded into /Boot directory.

Page 34 of the Foundry Networks M2404F user manual — Downloading a NI-M2404WebView Image Using TFTP
Page 34 · click to enlarge
Page 34
6. Configure the switch to boot with the newly downloaded image. This is done by selecting boot application and boot device.

device-name#config boot-param device-name(boot param)#application device-name(boot param)#device local device-name(boot param)#exit

Example:

device-name#config boot device-name(boot param)#application M2404v2.0.bin device-name(boot param)#device local device-name(boot param)#exit

7. Reset the switch using one of the reload commands. Note that, if you are connected to the switch through Telnet, your Telnet session will be disconnected.

Select from the following reload commands:

1. reload save - this command updates the device's startup configuration to match the running configuration and reboots the switch.
2. reload to-defaults – this command resets the device's startup configuration to match the factory defaults and reboots the switch.

After the execution of the command, confirmation is required [y/n]. Enter “y” to confirm the command.

Example with “reload” command:

device-name#reload save

Save current configuration and reboot the Switch ?

[y/n]y

Example with “reload to-defaults” command:

device-name#reload to-defaults

Restore factory setting and reboot the Switch ?

[y/n]y
8. After the switch reboots, use the show version command to check the version.

Downloading a NI-M2404WebView Image Using TFTP

To download a NI-M2404WebView software image to the switch from a TFTP server, proceed as follows:

Page 35 of the Foundry Networks M2404F user manual — Software Upgrade via Ethernet Port (Outband)
Page 35 · click to enlarge
Page 35
1. Copy the software image file to the appropriate TFTP directory on the workstation.
2. Log into the switch through the console port or through a Telnet session.
3. Download the software image from the TFTP server using the copy java command in Privileged (Enable) mode:

device-name#copy java <TFTP URL> [<destination file name>]

Example:

device-name#copy java tftp://192.192.54.10/NI M2404WebViewL3- V3.3.9.img

NOTE

The switch remains operational while the image is downloaded.

The Java image is downloaded into /Java directory.

4. Use the show version command to check the Java version on the switch.

Software Upgrade via Ethernet Port (Outband)

The switch has an Ethernet port which allows the user to access it for management purposes or software upgrades. This port, labeled ETH, is on the left side of the switch’s front panel and is not one of the switched ports. In order to configure this port for IP, the following commands must be used (from config mode):

device-name(config)#interface Outband0 device-name(config Outband0)#ip addr 10.1.1.7/8

This command will assign the IP address 10.1.1.7 and the netmask 255.0.0.0.

In order to see the current configuration of this IP interface, the following command should be used (from Privileged (Enable) mode):

device-name#show ip interfaces

In order to save the new Outband0 interface IP address, use the write command (from Privileged (Enable) mode).

Page 36 of the Foundry Networks M2404F user manual — REMEMBER:
Page 36 · click to enlarge
Page 36

Hot-swapping a Power Supply

The switch has two redundant power supplies, and can be operated when only one power supply is connected and powered on, or with both power supplies active. When both power supplies are active, you can remove or replace one power supply unit without interrupting the operation of the switch.

To extract a power-supply unit, release the panel screws on both sides of the unit and draw the unit out of its slot. Insert the replacement unit in the slot, push it carefully all the way in and fasten the panel screws.

Foundry Networks M2404F — Hot-swapping a Power Supply diagram (page 36)
Fig. 19 · Hot-swapping a Power Supply
Figure 16Extracting a Power-Supply Unit

CAUTION

To avoid improper ventilation to the switch’s internal circuitry and units, never leave an empty slot uncovered. If a removed power supply is not replaced, insert the supplied blank PSU filler into the slot and fasten it to the panel with the two screws.

NOTE

Before extracting a power supply unit while the switch is running, verify that the other power supply is properly functioning, as indicated by the corresponding PSU LEDs on the front panel.

REMEMBER:

Both power-supply fans may function even if only one power supply is connected, to prevent overheating. A working fan does not indicate that the power supply on which it is assembled is active.

Panel screws

Page 37 of the Foundry Networks M2404F user manual — Operating Conditions
Page 37 · click to enlarge
Page 37

Specifications

Physical Specifications

Dimensions

Width 440 mm (17.4”)

Height 44 mm (1.73”)

Depth 419 mm (16.5”)

Chassis without PSU 3.7 kg (8.2 lbs)

Each AC Power Supply 0.6 kg (1.3 lbs)

Each DC Power Supply 0.6 kg (1.3 lbs)

Operating Conditions

Voltage100-120 VAC@ 5A or [email protected]
Frequency50/60Hz
Voltage-48VDC typical (-36V to -60VDC) @ 3A
Operating temperature0 °C to 45 °C (32 °F to 104 °F)
Short term extended temperature-20 ° C – 60 ° C (-4 ° F - 140 ° F)
Humidity0 - 95% non-condensing
Relative Humidity5% to 90%, @45 °C (104 °F), non-condensing
Operating Altitude6,600 ft (2,012 m)
Storage Temperature-25 ºC to 70 ºC (-13 ºF to 158 °F)
Storage Humidity95% maximum relative humidity, non-condensing
Storage Altitude15,000 ft (4,500 m) maximum

Weight · AC power source · DC power source

Page 38 of the Foundry Networks M2404F user manual — EN 61000-3-2
Page 38 · click to enlarge
Page 38

Environment: The equipment is designed for use in indoor applications only.

Management Features

InbandIntegrated SNMP agent

Java applet , Telnet and SSH

MIBs Supported:

MIB II, Bridge MIB, Private MIB ,RMON MIB (Groups 1,2,3,9)

Traps/AlarmsSNMP traps to NMS
Console PortFor initial configuration via dedicated RJ-45 connector

Out-of-band Ethernet Port:

For Software Update via dedicated RJ-45 connector

Software Download:

Safety and Electromagnetic Compatibility

Safety

EN/ UL 60950-1, CAN/CSA C22.2 No. 60950-1-03 and IEC 60950:2001

EMC

EN 550221998 + A1:2000 class A, EN 300386 V1.3.1:2001, harmonized under EMC directive 89/336/EEC

EN55024 (CE mark) (Immunity) for Information Technology Equipment

ICES-003 (Canada) (Class A)

AS/NZ 55022 (Australia) (Class A)

VCCI CISPR 22 (Japan) (Class A)

ETSI 300 386 Telecommunication Centers

EN 61000-3-2

EN 61000-3-3

EN 61000-6-1

EIA 232 protocol · VT-100 compatible · Via TFTP

Page 39 of the Foundry Networks M2404F user manual — VCCI (Japan) (Class A)
Page 39 · click to enlarge
Page 39

FCC 47 CFR: 2003 part 15 subpart B, class A

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.

CISPR 22 CLASS A Warning

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

VCCI (Japan) (Class A)

This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

Foundry Networks M2404F — VCCI (Japan) (Class A) diagram (page 39)
Fig. 20 · VCCI (Japan) (Class A)
Page 41 of the Foundry Networks M2404F user manual — FCC 47 CFR: 2003 part 15 subpart B, class A
Page 41 · click to enlarge
Page 41

energía retirado no se reemplaza, inserte el relleno PSU en blanco provisto en el slot y asegúrelo al panel con los dos tornillos.

MISE EN GARDELes modifications ou changements apportés à ce dispositif n’ayant pas été

expressément approuvés par la partie responsable d’en évaluer la conformité peuvent annuler le droit de l’utilisateur à utiliser cet équipement.

expresamente aprobados por la parte responsable del cumplimiento de las normas podrían anular la autoridad del usuario para operar este equipo.

MISE EN GARDE: Pour les systèmes C.C., utilisez un fil de mise à la terre de calibre 10 AWG

(American Wire Gauge) minimum. Ce fil doit être relié à un connecteur à sertir homologué, serti avec l’outil approprié. Le connecteur à sertir unique devrait permettre le rattachement aux deux vis de borne de terre sur l’enveloppe.

calibre 10 AWG (Calibración de cables americana), por lo menos. El cable de AWG deberá acoplarse a un conector ondulado normalizado, ondulado con la herramienta apropiada. El conector ondulado simple deberá permitir fijación a los dos tornillos de conexión a tierra en el armario.

MISE EN GARDEPour le circuit d’alimentation C.C. du système, assurez-vous de la présence

d’un disjoncteur de 10 ampères sur l’entrée vers le bloc d’alimentation.

exista un cortacircuitos de 10 amperios en la entrada al bloque terminal.

Ask about the Foundry Networks M2404F

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Foundry Networks M2404F

Be the first to ask — other owners or our team will answer.

Original document

Foundry Networks M2404F manual PDF

46 pages·573 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…