Installation Guide
4980 Great America Parkway Santa Clara, CA 95054
Tel 408.207.1700
™ · January 2007

Copyright © 2007 Foundry Networks, Inc. All rights reserved. No part of this work may be reproduced in any form or by any means – graphic, electronic or mechanical, including photocopying, recording, taping or storage in an information retrieval system – without prior written permission of the copyright owner. The trademarks, logos and service marks ("Marks") displayed herein are the property of Foundry or other third parties. You are not permitted to use these Marks without the prior written consent of Foundry or such appropriate third party. Foundry Networks, BigIron, FastIron, IronView, JetCore, NetIron, ServerIron, TurboIron, IronWare, EdgeIron, IronPoint, the Iron family of marks and the Foundry Logo are trademarks or registered trademarks of Foundry Networks, Inc. in the United States and other countries.

This equipment is for use in a restricted access area by qualified personnel only. To avoid electric shock, do not perform any servicing other than those contained in the unpacking instructions.
This equipment contains Electrostatic Discharge (ESD) sensitive components. Use ESD protection before servicing or installing components of this system.
Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Remove the power cord from a power supply before you install it in or remove it from the device. Otherwise, the power supply or the device could be damaged as a result. (The device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source.)
All devices with DC power supplies are intended for installation in restricted access areas only. A restricted access area is where access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.
The equipment is designed to be used with Class 1 Laser fiber optic transmitters which may endanger your eyes.
Do not look directly into the fiber optic cables or transmitter.
HIGH VOLTAGE
Disconnect the product from the power line before removing the cover. Any adjustment and maintenance of the opened device should be done only while the device is disconnected from its source of power and should only be performed by qualified personnel, authorized by Foundry Networks.
January 2007 © 2007 Foundry Networks, Inc. ii

GROUNDING
Before connecting the product to the power line, make sure that the protective ground terminal of the device is connected to the safety ground conductor of the mains power cord.
The main power supply plug should only be inserted in a socket outlet provided with a connected safety ground. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding). Any interruption of the protective (grounding) conductor or disconnection of the protective ground terminal can make the device unsafe to use. Intentional interruption is prohibited.
This equipment has a connection between the earthed conductor of the DC supply circuit and the grounding conductor.
WIRING FOR NATIONAL POWER PLUG
A mains power cable according to National Electrical Code (NEC) with molded IEC socket is supplied with each unit. The specific national mains power plug should be wired as follows:
LINE VOLTAGE
Before connecting the product to the power line, make sure the voltage of the power source matches the requirements of the product, as marked on the label located near the power connectors.
DC POWER SOURCE
The DC power source should be protected with a branch circuit over- current protection rated at 10Amp, located in the building installation
January 2007 © 2007 Foundry Networks, Inc. iii



Who Should Use This Guide
The procedures in this manual are for trained and qualified service personnel who are proficient with network switching and routing concepts. Installation, replacement and maintenance of the equipment described in this guide may only be done by trained and qualified service personnel.
This document contains the following chapters.
How to use the Command Line Interface (CLI) to configure the platform and monitor its temperature, the power source status and the status of the fans.
Set of basic built in tests performed automatically at startup and optionally by user’s request.
How to replace an access module or a redundant power-supply unit without interrupting operation.
Chapter Contains

This document uses the following formatting styles and conventions:
o Text issued by the device software is represented by regular characters.
o In command syntax specifications, text to be entered by the user is represented as follows:
Command names and keywords appear as bold upright characters.
Argument values (numeric or literal) that the user must supply are
represented by bold italic characters, enclosed in angle-brackets.
range of numerical values, and represents a character string.
o In coded examples, all text demonstrated as entered by the user appears in bold upright characters.
The software used for initial and network configuration of the device is described in the Software User Guide.
User Documentation for NetIron M2404 Software and the Java™-based graphical manager may be downloaded from the Foundry Website (www.foundrynetworks.com).

Introduction
High powered networks require a combination of speed and robust services support to be able to provide the intensive and fluctuating demands of their end users. To answer these requirements, the network needs to provide data transmission at wire speed performance in a non-blocking fashion. This switch is an enhanced Metro Ethernet CPE platform designed to provide wire speed non-blocking Layer-2 and Layer-3 switching architecture as well as Hierarchical Virtual Private LAN Services (HVPLS) hubs-and-spokes and MPLS based rings support.
The platform capabilities include Ethernet LAN/ Line services, use of advanced Hierarchical QoS (tens of thousands of queues) as well as Hierarchical Virtual Private LAN Services (HVPLS) hubs-and-spokes and MPLS based rings support. The platform offers services convergence such as voice, data and video over Gigabit Ethernet, Enhanced Gigabit Ethernet (MPLS/ VPLS).
There are two flavors to the NetIron M2404, the NetIron M2404C and the NetIron M2404F.
(1) NetIron M2404C accommodates 24 Fast Ethernet copper ports and 4 Gigabit Ethernet ports;
(2) NetIron M2404F accommodates 24 Fast Ethernet fiber ports and 4 Gigabit Ethernet ports.
The platforms are identical in their performance.
Throughout this guide, both switches are referred to as “NetIron M2404”, “the platform” or “the switch”, unless relating to a specific platform.





Front Panel
Enhanced GigE Ports 100baseX Ports GigE Ports
Switch Management Ports (Outband Port on
PSU LEDs Reset Button
top and Console Port on bottom)
Enhanced GigE Ports 10/100baseTX Ports GigE Ports

Switch Management Ports (Outband Port on
PSU LEDs Reset Button
top and Console Port on bottom)
To prepare for installation, make sure you have an ESD wrist strap that can be attached to a grounded metal surface. Put on the ESD wrist strap and ground yourself by attaching the clip end to a grounded metal surface (such as an equipment rack) to act as ground.
For safety reasons, the ESD wrist strap should contain a series 1 meg ohm resistor.
To install an SFP transceiver into a port, do the following:

When inserting an SFP tranceiver into ports marked 27 or 28, verify that the SFP is facing upside -down (as shown in figure below). All other SFP ports on the switch face right-side up.



For NetIron M2404C: 10/100baseTX Ports 24 RJ-45 sockets with 10/100 Mbps LAN speed auto sensing, marked 1 to 24.
GigE Dual-Mode Ports Two dual-mode1000baseX interface (SFP) or 10/100/1000BaseT (RJ45) marked 25 and 26.
Enhanced GigE Ports Two 1000baseX interface (SFP) marked 27 and 28. Please note that the SFP transceivers are inserted into the slot, belly-down, as shown in figure above.
RJ45 socket for CLI configuration and management of the unit.
RJ45 socket with 10/100 Mbps LAN speed auto sensing for out- of-band Ethernet management and software update.
RST Button Reset button. To avoid accidental activation, the button is recessed behind the panel. Press with a pin or a similar narrow object.
For NetIron M2404F: 100baseX Ports 24 SFP sockets marked 1 to 24.

GigE Dual-Mode Ports Two dual-mode1000baseX interface (SFP) or 10/100/1000BaseT (RJ45) marked 25 and 26.
Enhanced GigE Ports Two 1000baseX interface (SFP) marked 27 and 28. Please note that the SFP transceivers are inserted into the slot, belly-down, as shown in figure above.
RJ45 socket for CLI configuration and management of the unit.
RJ45 socket with 10/100 Mbps LAN speed auto sensing for out- of-band Ethernet management and software update.
RST Button Reset button. To avoid accidental activation, the button is recessed behind the panel. Press with a pin or a similar narrow object.
The following descibes the LEDs on the chassis.
ETH Ethernet management interface status.
FLT Platform HW fault. • Off – Switch hardware OK.
MNG CPU controller is processing management tasks.
STS General platform status. • Off – Platform processing boot loader.
PSU #1 PSU #1 status. • Green – PS #1 functioning.
PSU #2 PSU #2 status. • Green – PS #2 functioning.

A status LED is associated with each port.

Port 3 Port 5 Port 7 Port 9 Port 11
Port 2 Port 4 Port 10 Port 6 Port 8
The port status LEDs (1 to 24) for NetIron M2404C are situated on the upper row of ports. The LED on the left side of each upper port is associated with that port. The LED on the right side of each upper port is associated with the port underneath that port.

Port 13 Port 15 Port 17 Port 19
Port 21 Port 23
Port 14 Port 16 Port 18 Port 20 Port 22
The port status LEDs (1 to 24) for NetIron M2404F are situated below each SFP.


Dual-mode port status LEDs are associated with dual-mode RJ45/SFP GiGE ports 25 and 26.
RJ45 Dual-Mode Port Status Indication
Link/Activity Left LED is Green
Disabled Right LED is Amber
SFP Dual-Mode Port Status Indication
Link Green · Activity Blinking green · Disabled Amber

Hot-swappable PSU #2 Fan apertures

Grounding studs On-off switch
Two AC Power supplies As specified in Power Supply Units.
Two grounding posts Designed for a UL-listed two-hole long-barrel 5/8 10 AWG compression lug. Burndy YAZV10-2TC14 or an equivalent is recommended.

Hot-swappable PSU #2 Fan apertures

PWR and Invert. Con.
PWR and Invert. Con.
Two DC Power supplies As specified in Power Supply Units.
Two grounding posts Designed for a UL-listed two-hole long-barrel 5/8 10 AWG compression lug. Burndy YAZV10-2TC14 or an equivalent is recommended.
Power is fed to the platform via two redundant hot-swappable power supply units (PSUs). The following PSU versions are available:
ACPS Dual-range AC power supply:
100-120 VAC@ 5A or 200-240VAC@ 2.5A 50/60 Hz
DCPS DC power supply:



DC power-supply terminals:
LEDs:
INVERT CON. PWR
The DC power supply panel has the following components:
Input terminals:
-48V/3A Negative DC input terminal
GND Ground terminal internally connected to the platform’s ground line
+BAT.RET Positive DC input terminal
Neither the +BAT.RET nor the -48VDC is connected to the GND terminal. If required, this can be performed externally by the user.
LEDs:
PWR Glows green when power is on
INVERT CON. Glows red to indicate inverted DC polarity
To avoid overheating of the components by improper air-flow, always keep empty slots covered. Use the panel screws on the supplied blank faceplates and blank filler to fasten the blanks to the appropriate empty slots.


Figure 13 Blank Filler for Empty Power-Supply Slot

This section provides installation and setup instructions. The platform can be installed in a standard 19-inch rack or as a standalone unit in a desktop configuration.
The shipping package includes the following items:
If the installation requires a power cord other than the one supplied with the device, make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device.
The platform is factory tested and inspected prior to shipment. In case of damage to the unit during shipment, contact your local dealer.
It is recommended that you keep the shipping package until the unit has been installed and verified as operational. The platform, like all electronic devices with static sensitive components, should be handled with care.
The supplied mounting brackets can be attached to the sides of the chassis either flush with the front panel (flush-mounting) or midway between the front and rear panels (mid-mounting). Use the supplied screws to fasten the mounting brackets to the chassis in the required position (flush or mid-mounting).
Before mounting any equipment onto the rack, make sure that there is generous clearance behind the rack for proper ventilation and for easy access to the rear components. Do not place objects that might obstruct airflow behind the chassis.

Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over.
Height 44 mm (1.73”) = 1 RU
Depth 414 mm (16.3”)
Distance between mounting holes Horizontal: 465 mm (18.3”) Vertical: 31.75 mm (1.25”) Vertical separation: 12.7 mm (0.5”)


When connecting an RJ-45/RJ-48 port to an end station, workstation or server, use a standard RJ-45/RJ-48 pin-out cable.
A simple menu-driven interface provides for system initialization and diagnostics. The Console interface is EIA232 VT-100 compatible. The primary purpose of the terminal interface is to set basic operational parameters.
The terminal interface is password protected. By default there is no password set for the terminal interface.
Using the enclosed serial cable (see table below for wiring), connect the RJ-45 connector to the connector marked “Console” and the other side to the 9-pin serial port connector on the back of your PC.
The supplied cable has the following pinout:
Switch Side PC Side
RJ-45 Pin # DB-9 Female
You can also use a RJ-45/DB-9 cable.
The DC supply source is to be located within the same premises as this equipment. The DC power source should be protected with a circuit breaker with a rating of 10Amp as disconnect device, connected to the non-grounding conductor. The unit shall be connected directly to the DC supply system; there shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the point of connection of the grounding electrode conductor.
This equipment shall be located in the same immediate area (such as, adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the grounding conductor, and also the point of grounding of the DC system. The DC system shall not be earthed elsewhere.

For each DC power block a set of a minimum 2x18AWG cables shall be used with suitable end terminal legs matching the conductor’s gauge. Use a RED lead to for the positive conductor and a BLACK lead for the negative conductor. It is recommended that only UL listed components be used for the DC power connections.
For a DC system, use a grounding wire of at least 10 American Wire Gauge (AWG). The 10 AWG wire should be attached to an agency- approved crimp connector, crimped with the proper tool. The crimp connector should allow for securement to both ground screws on the enclosure.
For the DC input circuit to the system, make sure there is a Listed 10 amp circuit, minimum -48Vdc, double pole, on the input to the terminal block. The input wiring for connection to the product should be Listed copper wire, 18 AWG, marked VW-1, and rated minimum 90 deg. C.
There is no connection needed for GND. Only the ground wire is connected to the Grounding Stud.
Before connecting power to the switch, make sure that both grounding posts in the rear panel are firmly connected to a reliable ground through a #10 AWG grounding wire terminated by a UL-listed two-hole long-barrel 5/8 10 AWG compression lug with hole size and spacing as shown in Figure 15 below.
The Burndy YAZV10-2TC14 or an equivalent UL-listed two-hole compression lug is recommended.

φ6.4 mm
To connect the switch to the ground, proceed as follows:
16 mm (5/8”) · (1/4”)

The device is provided with SFP sockets in which fiber optic transceivers may be installed. In order to meet the safety requirement of Class 1 fiber optic laser emission levels, only fiber optic transceivers which comply with IEC 60825-1 or IEC 60825-2 and FDA 21 CFR 1040.10 and CFR 1040.1 must be used.

Initial Configuration
The Configuration command-language interface (CLI) is accessed by using a VT-100 (or compatible terminal) to the console port of the switch. The terminal port parameters are fixed at: 9600 bps, 8 data bits, 1 stop bit, no parity and without flow control. This provides a convenient method for initial setup of the switch. System parameters are stored in a non-volatile memory. They need to be set up only during the initial setup or when the system has been reset to the factory defaults.
The following keys are used to access the menu:
Enter Ends an input line
Backspace Clears last character in input mode
Tab Auto-Completes a command
A screen similar to the following example appears on the Console Port at power up or reset:
//////////////////////////////////////////////////////////////////// // // Foundry Networks // // Switch model : NETIRON M2404F // SW version : 2.0.00 created January 12 2007 - 21:35:37 /////////////////////////////////////////////////////////////////// User Access Verification Password:
There is no default password, press for password.
You can configure the password later.
Type ? to display the available commands:
device-name>? alias An alias of a command dir List files in flash. display Display file. enable Turn on privileged mode command exit Exit current mode and down to previous mode help Description of the interactive help system ls List files in flash. no Negate a command or set to defaults

quit Disconnect and logout show Show running system information terminal Terminal configuration setup who Display who is on vty
To continue initial configuration procedure perform the following steps:
Example:
The show command can be used to display a variety of parameters: Setup Configuration and others. To view the show command options type: show ?
At this point the Initial configuration setup is completed and the switch can be accessed using Ping or Telnet commands.
A variety of TFTP Server programs can be used by the host computer where the software images and configuration files are located. The only information that is required by the TFTP Server is the location of the file on the host computer’s file system.
It is recommended that the configuration be saved in an external text backup file. To write the backup configuration file, use the command copy.
To view the copy command options type: copy ?
device-name#copy ? FILE-NAME Source file. Format: [[device/]path]file-name device: flash: - local file system tftp://A.B.C.D - TFTP server Example: tftp://1.1.1.1/directory/filename.bin

application Application downloading image java Java downloading image running-config Copy running config... startup-config Startup configuration data
To write the backup configuration file, type:
device-name#copy startup-config
is the file where the configuration file was saved.
The configuration file can be easily downloaded, using the copy command. Type:
copy tftp:/// startup-config
is the file where the configuration file was saved.
The copy command uses TFTP protocol for its execution, so prior to using the copy command, verify that the TFTP Server program is executed by the addressed computer.
Use the reload command to reload the factory defaults configuration.
device-name#reload to-defaults
Restore factory setting and Reboot the Switch !
Rebooting ...
The reload to-defaults command does NOT change the IP address and netmask of the switch.
Should the temperature reach the configured upper limit, the unit will send an SNMP trap to the management station. If this occurs, the user is requested to make sure that all unit ventilation airways are free and disengaged and that the fans are functioning.

Viewing the Status:
device-name#show temperature
CPU Temperature = 28C / 82F
device-name#show temperature high-limit CPU Temperature high limit = 20C / 68F
Configuring Temperature Management Parameters:
device-name#configure terminal
device-name(config)#monitor temperature
device-name(config monitor temperature C)#limit NUMBER Value of limit for alerting current test
device-name(config monitor temperature C)#limit 70
Viewing the Temperature Setting from a Running Configuration:
device-name#show running-config Building the configuration ... ! Current Configuration: ! ! Version 2.0 ! password a1FhfHKwXHFlU ip address 10.4.1.5 255.255.0.0 ! ! Switch Monitoring configuration: ! monitor temperature enable limit 70 !
Restoring the Default Value:
device-name#configure terminal
device-name(config)#monitor temperature
device-name(config monitor temperature C)#default

Viewing the status during system boot:
BUILT-IN SELF TEST CPU Core Test : Passed CPU Interface Test : Passed Data Buffer Test : Passed Power Supply Test : Passed On-board Power Test : Passed Fan Test : Passed
Viewing the status during operation:
The Power Supply status is available on the DC and dual-feed AC models only. The possible values are OK, Failed, and Not Installed.
device-name#show power-supply Power supply 1 : OK Power supply fan 1 : OK

The BIST performs a set of basic hardware and configuration validity tests. Tests in the BIST are sorted into several groups – for example, the tests of the Power Supply units belong to a Power Supply Test group.
Startup BIST - The BIST is performed automatically on startup. The results are summarized on the terminal before the switch banner.
BIST by request - A user may request BIST execution at any time by using a CLI command.
The current BIST status may be read and cleared by using CLI commands. When the BIST detects a failure in any of the tests, it causes the Status LED indicator to blink.
The switch supports the following tests:
Table 1 describes the tests.
CPU Core Test Checks CPU block integrity
CPU Interface Test Checks the existence of the UART (register write/read operation). Both COM1 and COM2 are checked.
Data Buffer Test Checks the integrity of NVRAM database.
Power Supply Test Checks the existence and status of the DC power supplies. If both DC power supplies are connected, the test will result with Passed. When one of the DC power supply is disconnected, the test will result with Failed.
Fan Test Checks the status of the 3 fans.
On-Board Power Test Checks the 5 On-Board Power levels: 3.2V, 2.5V, 1.8V, 1.5V and
Temperature Test Validates temperature ranges inside the device and tests temperature sensors.
If any of the BIST tests fail, the FLT LED starts blinking. To display BIST results, perform the following steps:
Test Description

To invoke a BIST by Request at any time while the switch is running, use the self-test command in Privileged (Enable) mode.
The switch will automatically start up in debug mode when one of the five On-Board power levels deviates by 2% above or below the required level. See the explanation below.
The startup BIST reports a summary of the results by BIST group. If all tests of the group pass, Passed is displayed for all groups.
Press any key to stop auto-boot... 0 auto-booting... Uncompressing 4329228 bytes... Loading image... 17671392 Init TFFS BUILT-IN SELF TEST CPU Core Test : Passed CPU Interface Test : Passed Data Buffer Test : Passed Power Supply Test : Passed On-board Power Test : Passed Fan Test : Passed
If any test in the group except the On-Board Power fails, Failed is displayed for the entire group and the switch starts normally. In such cases, the switch starts in debug mode (switching disabled and the switch is running with the default configuration). If one of the On-Board Power level checks fails, the switch will not initialize the ports and will start in a special debug mode, as shown below:
Press any key to stop auto-boot... 0 auto-booting... Uncompressing 4329228 bytes... Loading image... 17671392 Init TFFS BUILT-IN SELF TEST CPU Core Test : Passed CPU Interface Test : Passed Data Buffer Test : Passed Power Supply Test : Passed On-board Power Test : Passed Fan Test : Passed

//////////////////////////////////////////////////////////////////// FOUNDRY NETWORKS // Switch model : FOUNDRY NETWORKS NETIRON M2404F 256M // // SW version : 2.0.00 created January 15 2007 - 21:35:37 //////////////////////////////////////////////////////////////////// User Access Verification Password: device-name>
In this case, you can enter into Enable mode as usual, and examine the detailed Self-Test results.
For example:
device-name#self-test Processing BIST by request... CPU Core Test : CPU Validation - Passed CPU Interface Test : UART Existence - Passed Data Buffer Test : Application Image Validity - Passed Java Agent Image Validity - Passed PROM Device Access Validity - Passed Power Supply Test : Power Supply 1 - Passed Power Supply Fan 1 - Passed Power Supply 2 - Not installed Power Supply Fan 2 - Not installed On-board Power Test : On-board Power 3.3V - Passed On-board Power 2.5V - Passed On-board Power 1.8V - Passed On-board Power 1.25V - Passed Fan Test : Fan 1 - Passed Fan 2 - Passed Fan 3 - Passed Temperature Test : Temperature - Passed

The executable software image contained on the platform can be upgraded via the network whenever new versions become available, reflecting changes in the MIBs or enhancements to the software. The software is stored in erasable Flash memory. It must be downloaded using the Trivial File Transfer Protocol (TFTP).
Table 2 displays an example of typical software image names.
The image name is a typical example. The numbers in the name are illustrative and should not be regarded as the latest released version numbers.
Typical Application Image Name Typical NI-M2404WebView Image Name
NetIron 2404 v2.0.00.bin NI-M2404WebViewL3-V3.6.8.img
Before you begin to download a software image using TFTP, take the following precautions:
To download a device software image to the switch from a TFTP server, proceed as follows:

Example:
device-name#dir Listing Directory flash:/: d S 2048 Jun 30 2005 17:56 Boot/ d S 2048 Jan 1 1993 00:04 Etc/ d S 2048 Jun 14 2005 12:01 Java/ d S 2048 Jan 1 1980 00:00 Log/ d S 2048 Jul 5 2005 21:36 Usr/ d SH 2048 Jan 1 1980 00:00 Hidden/ - 260 Jan 1 1993 00:00 profile.cfg - 43796 Jul 5 2005 21:26 dflt_startup_bin.cfg - 5382 Jul 5 2005 21:26 dflt_startup.cfg Free disk space 5655104
device-name#del <filename>
Example:
device-name#del /Boot/Oldimage.bin
device-name#copy application <TFTP URL> [<destination file name>]
Example:
device-name#copy application tftp://192.192.54.10/M2404Cv2.0.bin
The switch remains operational while the image is downloaded.
The application is downloaded into /Boot directory.

device-name#config boot-param device-name(boot param)#application device-name(boot param)#device local device-name(boot param)#exit
Example:
device-name#config boot device-name(boot param)#application M2404v2.0.bin device-name(boot param)#device local device-name(boot param)#exit
Select from the following reload commands:
After the execution of the command, confirmation is required [y/n]. Enter “y” to confirm the command.
Example with “reload” command:
device-name#reload save
Save current configuration and reboot the Switch ?
Example with “reload to-defaults” command:
device-name#reload to-defaults
Restore factory setting and reboot the Switch ?
To download a NI-M2404WebView software image to the switch from a TFTP server, proceed as follows:

device-name#copy java <TFTP URL> [<destination file name>]
Example:
device-name#copy java tftp://192.192.54.10/NI M2404WebViewL3- V3.3.9.img
The switch remains operational while the image is downloaded.
The Java image is downloaded into /Java directory.
The switch has an Ethernet port which allows the user to access it for management purposes or software upgrades. This port, labeled ETH, is on the left side of the switch’s front panel and is not one of the switched ports. In order to configure this port for IP, the following commands must be used (from config mode):
device-name(config)#interface Outband0 device-name(config Outband0)#ip addr 10.1.1.7/8
This command will assign the IP address 10.1.1.7 and the netmask 255.0.0.0.
In order to see the current configuration of this IP interface, the following command should be used (from Privileged (Enable) mode):
device-name#show ip interfaces
In order to save the new Outband0 interface IP address, use the write command (from Privileged (Enable) mode).

The switch has two redundant power supplies, and can be operated when only one power supply is connected and powered on, or with both power supplies active. When both power supplies are active, you can remove or replace one power supply unit without interrupting the operation of the switch.
To extract a power-supply unit, release the panel screws on both sides of the unit and draw the unit out of its slot. Insert the replacement unit in the slot, push it carefully all the way in and fasten the panel screws.

To avoid improper ventilation to the switch’s internal circuitry and units, never leave an empty slot uncovered. If a removed power supply is not replaced, insert the supplied blank PSU filler into the slot and fasten it to the panel with the two screws.
Before extracting a power supply unit while the switch is running, verify that the other power supply is properly functioning, as indicated by the corresponding PSU LEDs on the front panel.
Both power-supply fans may function even if only one power supply is connected, to prevent overheating. A working fan does not indicate that the power supply on which it is assembled is active.
Panel screws

Physical Specifications
Width 440 mm (17.4”)
Height 44 mm (1.73”)
Depth 419 mm (16.5”)
Chassis without PSU 3.7 kg (8.2 lbs)
Each AC Power Supply 0.6 kg (1.3 lbs)
Each DC Power Supply 0.6 kg (1.3 lbs)
Weight · AC power source · DC power source

Environment: The equipment is designed for use in indoor applications only.
Java applet , Telnet and SSH
MIBs Supported:
MIB II, Bridge MIB, Private MIB ,RMON MIB (Groups 1,2,3,9)
Out-of-band Ethernet Port:
For Software Update via dedicated RJ-45 connector
Software Download:
EN/ UL 60950-1, CAN/CSA C22.2 No. 60950-1-03 and IEC 60950:2001
EN55024 (CE mark) (Immunity) for Information Technology Equipment
ICES-003 (Canada) (Class A)
AS/NZ 55022 (Australia) (Class A)
VCCI CISPR 22 (Japan) (Class A)
ETSI 300 386 Telecommunication Centers
EN 61000-3-3
EN 61000-6-1
EIA 232 protocol · VT-100 compatible · Via TFTP

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.


energía retirado no se reemplaza, inserte el relleno PSU en blanco provisto en el slot y asegúrelo al panel con los dos tornillos.
expressément approuvés par la partie responsable d’en évaluer la conformité peuvent annuler le droit de l’utilisateur à utiliser cet équipement.
expresamente aprobados por la parte responsable del cumplimiento de las normas podrían anular la autoridad del usuario para operar este equipo.
MISE EN GARDE: Pour les systèmes C.C., utilisez un fil de mise à la terre de calibre 10 AWG
(American Wire Gauge) minimum. Ce fil doit être relié à un connecteur à sertir homologué, serti avec l’outil approprié. Le connecteur à sertir unique devrait permettre le rattachement aux deux vis de borne de terre sur l’enveloppe.
calibre 10 AWG (Calibración de cables americana), por lo menos. El cable de AWG deberá acoplarse a un conector ondulado normalizado, ondulado con la herramienta apropiada. El conector ondulado simple deberá permitir fijación a los dos tornillos de conexión a tierra en el armario.
d’un disjoncteur de 10 ampères sur l’entrée vers le bloc d’alimentation.
exista un cortacircuitos de 10 amperios en la entrada al bloque terminal.