FastIron LS 648
4980 Great America Parkway Santa Clara, CA 95054
Tel 408.207.1700
™ · September 2007

Copyright © 2007 Foundry Networks, Inc. All rights reserved.
No part of this work may be reproduced in any form or by any means – graphic, electronic or mechanical, including photocopying, recording, taping or storage in an information retrieval system – without prior written permission of the copyright owner.
The trademarks, logos and service marks ("Marks") displayed herein are the property of Foundry or other third parties. You are not permitted to use these Marks without the prior written consent of Foundry or such appropriate third party.
Foundry Networks, BigIron, FastIron, IronView, JetCore, NetIron, ServerIron, TurboIron, IronWare, EdgeIron, IronPoint, the Iron family of marks and the Foundry Logo are trademarks or registered trademarks of Foundry Networks, Inc. in the United States and other countries.
F-Secure is a trademark of F-Secure Corporation. All other trademarks mentioned in this document are the property of their respective owners.


Introduction
This guide describes the following product families from Foundry Networks:
This guide includes procedures for installing the hardware and configuring essential, basic parameters such as permanent passwords and IP addresses. The basic software configuration procedures show how to perform tasks using the CLI. This guide also includes instructions for managing and maintaining the hardware.
This guide applies to the following FastIron LS products:
This edition describes the following software release:
This guide is designed for network installers, system administrators, and resellers who will install the FastIron hardware. This guide assumes a working knowledge of Layer 2 and Layer 3 Switching and routing concepts.
This guide uses the following typographical conventions to show information:
Italic highlights the title of another publication and occasionally emphasizes a word or phrase.
Bold highlights a CLI command.
Bold Italic highlights a term that is being defined.

The following Foundry Networks documents supplement the information in this guide.
Foundry Networks technical support will ensure that the fast and easy access that you have come to expect from your Foundry Networks products will be maintained.
Technical requests can also be sent to the following email address:
Contact Foundry Networks using any of the methods listed above for information about the standard and extended warranties.

This chapter contains an overview of the FastIron® LS Layer 2 Compact Switch.
This chapter contains the following information:
The FastIron LS Series includes two models, the FastIron LS 624 with an option for up to three 1-port 10 Gbps Ethernet modules, and the FastIron LS 648 with an option for up to two 1-port 10 Gbps Ethernet modules. Both models support an optional external redundant AC power supply that can power up to four units.
The following sections describe the physical characteristics of the FastIron LS models. For more details about physical dimensions, power supply specifications, and pinouts, see “Hardware Specifications” on page 2-1.
The FastIron LS provides high 10/100/1000 port density and 10-Gigabit Ethernet uplinks in a compact form factor.

The following figures show the front panels of these FastIron LS models.
Figure 2.1 FastIron LS 624
Figure 2.2 FastIron LS 648
45 48 47 46
Figure 2.3 FastIron LS 624 and 648 rear panel
RPS DC In 12V 13A
Figure 2.4 FastIron LS 624 with module installed
Figure 2.5 FastIron LS 624 and 648 rear panel with modules Installed
RPS DC In 12V 13A
Each device’s front panel includes the following control features:
The serial management interface enables you to configure and manage the device using a third-party terminal emulation application on a directly connected PC. A straight-through EIA/TIA DB-9 serial cable (M/F) ships with the device. The serial management interface (the Console port) is located in the right corner of the front panel.
The reset button allows you to restart the system without removing power or using the CLI or Web management interface. The button is located to the left of the serial management interface and is recessed to prevent it from being pushed accidentally.
The FLS624 and FLS648 provide the following interfaces:

For information about the type of fiber optic modules supported on the FastIron LS, see “Fiber Optic Modules” on page 2-7.
FastIron LS 10/100/1000BASE-T Ports The switches contain 24/48 RJ-45 ports that operate at 10 Mbps or 100 Mbps, half or full duplex, or at 1000 Mbps, full duplex. Because all ports on these switches support automatic MDI/MDI-X operation, you can use straight- through cables for all network connections to PCs or servers, or to other switches or hubs. (See “1000BASE-T Pin Assignments” on page B-3.) In addition, it is ideal and preferred to use MDIX cable for switch-to-switch connections.
Each of these ports support auto-negotiation, so the optimum transmission mode (half or full duplex), and data rate (10, 100, or 1000 Mbps) can be selected automatically. If a device connected to one of these ports does not support auto-negotiation, the communication mode of that port can be configured manually.
Table 2.2 describes the network interfaces supported on the FastIron LS. For network interface specifications, see the table “Cable length summary table” on page 2-7.
Product Overview

These switches include two slots on the rear panel for single-port 10GBASE uplink modules with XFP transceivers, and a single port CX4 module. The 10GBASE transceivers operate at 10 Gbps full duplex with support for asymmetric flow control (that is, the port honors incoming pause frames, but does not originate pause frames).
10 Gbps CX4 Ports This section describes the 10-GbE CX4 module.
The single-port CX4 module is installed in the FLS624 and FLS648 (shown in Figure 2.6). You can order the FastIron LS with a single-port CX4 module installed at the factory, or you can later upgrade your device. This module is a 10-GbE-CX4 Ethernet uplink card. It can perform data transmission directly through copper links to 15m(extended 30m) in length.
The following single-port CX4 module is supported:
Link and Activity LEDs on the module faceplates indicate operational status:
When this module is installed, the show media command returns the following display:
FLS624 Switch(config-if-e1000-0/1/5)#show media 0/1/1: C 0/1/2: C 0/1/3: C 0/1/4: C 0/1/5: C 0/1/6: C 0/1/7: C 0/1/8: C0/1/9: C 0/1/10: C 0/1/11: C 0/1/12: C 0/1/13: C 0/1/14: C 0/1/15: C 0/1/16: C0/1/17: C 0/ 1/18: C 0/1/19: C 0/1/20: C 0/1/21:M-SX 0/1/22: C 0/1/23: C 0/1/24: C0/2/1:CX40/3/ 1:XG-LR 0/4/1:1310-NM
Figure 2.6 Single-port 10-GbE-CX4 Module
Cable Specifications for New Module The following cable specifications apply to the CX4 port, which is included in the new 10GbE interface module (FLS-1XGC):
Figure 2.7 shows the CX4-grade cable.
10-GbE CX4 Module

Figure 2.7 CX4 Transceiver Cable
CX4 Transceiver Infiniband cable
These switches include a display panel for key system and port indications that simplify installation and network troubleshooting. The LEDs, which are located on the front panel for easy viewing, are shown below and described in the following tables.
Figure 2.8 Port LEDs
On/Flashing Amber Port has a valid link at 10 or 100 Mbps. Flashing indicates activity.
On/Flashing Green Port has a valid link at 1000 Mbps. Flashing indicates activity.
Off The link is down.

Figure 2.9 System LEDs

Amber Primary power supply is active, RPS is on standby.
Off Redundant power supply is off or not plugged in.
Stack Master1 Green Switch is the Master unit of the stack. State may include topology discovery, IP assignment, or normal operations.
Flashing Green Switch is the Master unit of the stack, system is initializing.
Amber Switch is operating as a Slave unit in the stack.
Stack Link1 Green Uplink and downlink operating normally.
Module Green An expansion module is installed and operating normally.
Amber An expansion module is installed but has failed.
Stack ID1 1-8 Indicates the switch stack ID.
The Master unit is numbered 1. (Note that If the master unit fails and a backup unit takes over, the stack IDs do not change.)
System Status LEDs · Fastlron LS 624

Figure 2.10 Module LED
Link/Activity On Port has a valid link at 10 Gbps.
On/Flashing Green Flashing indicates activity.
Off The link is down.
A list of the types of fiber optic modules supported on Layer 2 Compact Switches can be found in “Cable length summary table” on page 2-7
NOTE: Some older SFP modules (mini-GBICs for Gigabit Ethernet ports) have latching mechanisms that are larger than the newer parts. These latches could interfere with one another when inserted side by side into a SuperX module. Avoid using these mini-GBICs side by side in the same module. These older modules are identified by the number PL-XPL-00-S13-22 or PL-XPL-00-L13-23 above the serial number. All newer mini-GBICs do not have this limitation.
There are two power receptacles on the rear panel of each switch. The standard power receptacle is for the AC power cord. The receptacle labeled “RPS” is for the optional redundant power supply.
The switch supports an optional redundant power supply (RPS), that can supply power to the switch in the event the internal power supply fails.
There are two power receptacles on the rear panel of each switch. The standard power receptacle is for the AC power cord. The receptacle labeled “RPS” is for the optional redundant power supply.
Figure 2.11 Power Supply Receptacles
RPS DC In 12V 13A
Power Socket Redundant Power Socket



This chapter describes how to physically install the FastIron LS.
This chapter contains the following topics:
Unpacking the hardware 3-1
Summary of installation tasks 3-3
Installing a redundant power supply 3-8
Mounting the device 3-5
Installing an Optional Module 3-14
Powering ON the device 3-16
Verifying proper operation 3-16
Attaching a PC or terminal to the Foundry device 3-16
Information about configuring IP addresses and connecting network devices is located in “Connecting Network Devices and Checking Connectivity”.
The Foundry LS systems ship with all of the following items. Please review the list below and verify the contents of your shipping container. If any items are missing, please contact the place of purchase.
Description See Page · Installation precautions 3-4 · Site preparation 3-5

To manage the system, you need the following items for serial connection to the switch or router:
You use the serial connection to perform basic configuration tasks, including assigning an IP address and network mask to the system. This information is required to manage the system using the Web management interface or IronView Network Manager or using the CLI through Telnet.

Installing a FastIron LS Switch
Follow the steps listed below to install your FastIron LS. Details for each of these steps are provided in this chapter and in the following chapter.
Task Where to Find More Information
1 Ensure that the physical environment that will host the device has the proper cabling and ventilation.
“Preparing the Installation Site” on page 3-5
2 Install any required optional modules into the switch. “Installing an Optional Module into the Switch” on page 3-14
2 Install the Foundry device on a desktop, in an equipment rack, or on the wall.
“Installing the Device” on page 3-5
3 Once the device is physically installed, plug the device into a nearby power source that adheres to the regulatory requirements outlined in this manual.
“Powering On the System” on page 3-16
4 Verify that the system LEDs are registering the proper LED state after power-on of the system.
“Verifying Proper Operation” on page 3-16
5 Attach a terminal or PC to the Foundry device. This will enable you to configure the device via the Command Line Interface (CLI).
“Attaching a PC or Terminal” on page 3-16
6 No default password is assigned to the CLI. For additional access security, assign a password.
“Assigning Permanent Passwords” on page 4-1
7 Before attaching equipment to the device, you need to configure an interface IP address to the subnet on which it will be located. Initial IP address configuration is performed using the CLI with a direct serial connection. Subsequent IP address configuration can be performed using the Web management interface.
“Configuring IP Addresses” on page 4-3
8 Once you power on the device and assign IP addresses, the system is ready to accept network equipment.
“Connecting Network Devices” on page 4-4
9 Test IP connectivity to other devices by pinging them and tracing routes.
“Testing Connectivity” on page 4-6
10 Continue configuring the device using the CLI or the Web management interface. You also can use IronView Network Manager to manage the device. See the Foundry IronView Network Management User’s Guide for information.
Foundry FastIron Configuration Guide
11 Secure access to the device. Foundry FastIron Configuration Guide
Task Number

Follow these precautions when installing a Foundry device.
CAUTION: Ensure that the device does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all devices installed on the same circuit as the device. Compare this total with the rating limit for the circuit. The maximum ampere rat- ings are usually printed on the devices near the input power connectors.

Installing a FastIron LS Switch
Ensure that the proper cabling is installed at the site. See “Hardware Specifications” on page 2-1 or www.foundrynetworks.com for a summary of supported cabling types and their specifications.
Before installing the device, plan its location and orientation relative to other devices and equipment. Switches can be mounted in a standard 19-inch equipment rack, on a flat surface, or on a wall. Be sure to follow the guidelines below when choosing a location.
The site should:
You can install Foundry systems on a desktop, in an equipment rack, or on the wall.

Figure 3.1 Attaching the adhesive feet

Before mounting the switch in a rack, pay particular attention to the following factors:
To mount devices in rack:

Installing a FastIron LS Switch
Figure 3.2 Attaching the brackets

Figure 3.3 Installing the device in a rack


Foundry Network’s External Redundant Power Supply (RPS2-EIF) can supply a maximum of 150 Watts of output power per port, a total of 600 Watts of backup power to four FasrIron devices in the event of an AC loss or failure of an internal power supply.
The system operates as a backup to a switch's internal power supply. If an internal power supply fails, the RPS will support the full load of the switch without affecting network operation.
The following devices are supported by the FastIron RPS2-EIF: Foundry FastIron LS624 and FastIron LS648.
Four power indicators and one fan indicator are located on the RPS’s front panel. The AC supply and DC backup receptacles are located on the RPS’s rear panel.
Figure 3.4 Front and rear panels

Redundant Power Sockets 4~3 Fans Redundant Power Sockets 2~1 Power Socket

Installing a FastIron LS Switch
The following diagram and tables describe the functions of the RPS2-EIF LEDs
FastIron RPS2-EIF
Port Status LEDs - RPS2-EIF
LED (1~4) Condition Status
Link Off The port does not have a valid connection to a switch.
On Yellow The port has a valid connection to a switch.
Flashing Yellow There has been a RPS internal power failure.
Activity Off The port is not providing power to the connected switch.
Flashing Green The port has been shut down due to one of the following conditions:
On Green The port is providing power to a connected switch.
System Status LEDs - RPS2-EIF
Power On Green AC power is being supplied to the RPS.
Off No AC power is being supplied to the RPS.
LED Condition Status

An RPS may be placed on a desktop or mounted in a rack.
RPS2-EIF units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location.
After unpacking the FastIron RPS2-EIF, check the contents to be sure you have received all the components. (See “Package Contents” on page 3-8.) Then, before beginning the installation, be sure you have all other necessary installation equipment.
If you plan to rack-mount the RPS, be sure to have the following equipment available:
FastIron RPS units can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow.
Before mounting the unit in a rack, pay particular attention to the following factors:

Installing a FastIron LS Switch


Figure 3.7 Attaching the adhesive feet

The following devices are supported by the FastIron RPS2-EIF: Foundry FastIron LS624 and FastIron LS648.
To connect switches to the RPS:
Figure 3.8 Power receptacle


Installing a FastIron LS Switch




3, 4, 5, 6 12 V 12 volts current
10 RPS Present Indicates that an RPS unit is attached and functioning
13 Power Good Indicates that power is being supplied to the RPS
Figure 3.9 Installing an optional module


Installing a FastIron LS Switch
To install an optional module into the switch, do the following:

Figure 3.10 Inserting an SFP transceiver into a slot
See Table 0.12 on page 2-7 for a list of compatible transceivers. To install an SFP transceiver, do the following:

After you complete the physical installation of the system, you can power on the system.
After you have installed a redundant power supply, verify that the device is working properly by plugging it into a power source and verifying that it passes the self test.
If your installation requires a different power cord than that supplied with the device, make sure you obtain a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device.
All of the port LEDs should flash momentarily, usually in sequence, while the device performs diagnostics. After the diagnostics are complete, the LEDs will be dark except for those that are attached by cables to other devices. If the links on these cables are good and the device has power, the link LEDs will light.
For more details on specific LED conditions after system start-up, see the section, “LEDs” on page 3-9 and “Hardware Specifications” on page 2-1.
To assign an IP address, you must have access to the Command Line Interface (CLI). The CLI is a text-based interface that can be accessed through a direct serial connection to the device and through Telnet connections. The CLI is described in detail in the Foundry FastIron X Series Configuration Guide.
You need to assign an IP address using the CLI. You can access the CLI by attaching a serial cable to the Console port. After you assign an IP address, you can access the system through Telnet, the Web management interface, or IronView Network Manager.
To attach a management station using the serial port:

Installing a FastIron LS Switch
The EIA/TIA 232 serial communication port serves as a connection point for management by a PC or SNMP workstation. Foundry switches come with a standard male DB-9 connector, shown in Figure 3.11.
Figure 3.11 Serial Port (DB-9 DTE) Pin-Out
Most PC serial ports also require a cable with a female DB-9 connector.
Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female.
Serial cable options between a Foundry switch or router and a PC or terminal are shown in Table 3.3.

No other pins are used.



Checking Connectivity
This chapter provides the details for connecting network devices.
Table 4.1 lists the tasks you must perform to connect your Foundry device, and shows where to get troubleshooting information for any problems that can arise.
1 Assigning Permanent Passwords 4-4
2 Configuring IP Addresses 4-3
3 Connect your device to another networking device. 4-4
4 Troubleshoot any problems that can arise. 4-7
By default, the CLI is not protected by passwords. To secure CLI access, Foundry strongly recommends assigning passwords. See the Foundry Security Guide.
The CLI contains the following access levels:
Step Task Page

You can set the following levels of Enable passwords:
To set passwords:
FLS648 Switch# configure terminal
FLS648 Switch(config)# enable super-user-password <text>
FLS648 Switch(config)# enable port-config-password
FLS648 Switch(config)# enable read-only-password
Passwords can be up to 32 characters long.
By default, the CLI does not require passwords. However, if someone has configured a password for the device but the password has been lost, you can regain super-user access to the device using the following procedure.
To recover from a lost password:
After the console prompt reappears, assign a new password.
FLS648 Switch> enable · FLS648 Switch(config)#

Connecting Network Devices and Checking Connectivity
You must configure at least one IP address using the serial connection to the CLI before you can manage the system using the other management interfaces. In addition, Foundry routers require an IP subnet address for the subnet in which you plan to place them in your network.
Foundry devices support both classical IP network masks (Class A, B, and C subnet masks, and so on) and Classless Interdomain Routing (CIDR) network prefix masks.
By default, the CLI displays network masks in classical IP address format (example: 255.255.255.0). You can change the display to the prefix format. See the Foundry FastIron X-Series Configuration Guide or the Foundry Enterprise Configuration and Management Guide.
To configure an IP Address on a device running Layer 2 software:
FLS648 Switch# erase startup-config
FLS648 Switch# configure terminal Privileged EXEC Level
FLS648 Switch(config)# Global CONFIG Level
FLS648 Switch(config)# ip address 192.22.3.44 255.255.255.0
FLS648 Switch(config)# ip default-gateway 192.22.3.1
FLS648 Switch> enable · or

Foundry devices support connections to other vendors’ routers, switches, and hubs, as well other Foundry devices.
See “Cable length summary table” on page 2-7
For port pinouts, see the section “Pinouts and Signaling” on page 2-6.
See “Cable Specifications” on page 2-7 for cable lengths and types.
For copper connections to Ethernet hubs, a 10/100BaseTX or 1000BaseT switch, or another Foundry device, a crossover cable is required (Figure 4.1 and Figure 4.2). If the hub is equipped with an uplink port, it will require a straight-through cable instead of a crossover cable.
Figure 4.1 UTP crossover cable

White/Green Stripe 1 2 3 4 5 6 7 8

Connecting Network Devices and Checking Connectivity
Figure 4.2 Straight-through Cable

Straight-through UTP cabling is required for direct UTP attachment to workstations, servers, or routers using network interface cards (NICs).
Fiber cabling is required for direct attachment to Gigabit NICs or switches and routers via fiber ports. See “Connecting a Network Device to a Fiber Port” on page 4-5.
All 10/100 and Gigabit Ethernet Copper ports on the Foundry FastIron devices support automatic Media Dependent Interface (MDI) and Media Dependent Interface Crossover (MDIX) detection. This feature is enabled on all 10/100 and Gigabit copper ports by default. For each port, you can disable auto MDI/MDIX, designate the port as an MDI port, or designate the port as an MDIX port.
For more information about this feature and how configure it, see the Foundry FastIron X-Series Configuration Guide.
For direct attachment from the Foundry device to a Gigabit NIC, switch, or router, fiber cabling with an LC connector is required.
To connect the Foundry device to another network device using a fiber port, you must do the following:
The following sections provide information about performing these tasks.
You must install a fiber optic module (SFP or XFP transceiver) in each Gigabit Ethernet and 10-Gigabit Ethernet fiber port you want to use.
You can install a new fiber optic module in a port while the FastIron LS is powered on and running.
Before installing one of these modules into the port, have the following on hand:
To install a fiber optic module, do the following:

To cable a fiber optic module, do the following:
To avoid problems with the connection between the fiber optic module (SFP (mini-GBIC) or XFP) and the fiber cable connectors, Foundry strongly recommends cleaning both connectors each time you disconnect and reconnect them. In particular, dust can accumulate in the connectors and cause problems such as reducing the optic launch power.
To clean the fiber cable connectors, Foundry recommends using the fiber-optic reel-type cleaner that shipped with your FastIron LS. You can also purchase this type of cleaner from the following Website:
http://www.fisfiber.com/Home_Page.asp
When not using an SFP or XFP connector, make sure to keep the protective covering on.
You can observe the LEDs related to network connection.
After you install the network cables, you can observe certain LEDs to determine if the network connections are functioning properly. Table 4.2 outlines the LEDs related to the network connections, the desired state of each LED, possible abnormal states of each LED, and what to do if an LED indicates an abnormal state.

Connecting Network Devices and Checking Connectivity
Link (Lnk) On (Green)
A link is established with the remote port.
Off A link is not established with the remote port. You can do the following:
Active (Act) On or blinking (Yellow)
The port is transmitting and receiving user packets.
Off for an extended period.
The port is not transmitting or receiving user packets. You can do the following:
If a problem persists after taking these actions, contact Foundry’s technical support.
LED Desired State · Meaning Abnormal State · Meaning/Action


This chapter provides instructions for maintaining the FastIron LS.
This chapter contains the following information:
Managing the FastIron LS temperature settings 5-1
Displaying management module CPU usage 5-4
Recommended hardware maintenance schedule 5-4
Installing or replacing a 10-GbE module 5-4
Replacing a fiber optic module (SFP (mini-GBIC) or XFP) 5-5
Cleaning the fiber-optic connectors 5-7
This section describes how to display temperature settings on the FastIron LS and how to change the temperature warning and shutdown levels.
The FastIron LS comes with a built-in temperature sensor. The temperature sensor causes the device to generate a Syslog message and SNMP trap if the temperature exceeds a specified warning level or shutdown level. If the device’s temperature exceeds the safe threshold (shutdown level), the device will reboot if it stays in the safe threshold for five minutes.
The software reads the temperature sensor according to the device poll time, which is 60 seconds by default. If the temperature equals or exceeds the shutdown temperature for five consecutive polls of the temperature by the software, the software will reboot the device to prevent damage.
Description See Page

You can use the CLI or Web management interface to do the following:
By default, the software polls the temperature sensor every 60 seconds to get the current temperature. This poll rate is controlled by the device poll time, which also controls how often the software polls other system components.
To display the temperature of a device, enter the following command at any level of the CLI:
FLS648 Switch> show chassis Power supply 1 not present Power supply 2 (NA - AC - Regular) present, status ok
Fan 1 failed Fan 2 failed Fan 3 failed Exhaust Side Temperature Readings:
The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or shutdown thresholds. The following methods describe how to view the system log on the device. If you have configured the device to use a Syslog server or SNMP trap receiver, see the documentation for the server or receiver.

Maintaining the FastIron LS Hardware
To display the system log, enter the following command at any CLI level:
FLS648 Switch# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns) Buffer logging: level ACDMEINW, 8 messages logged level code: A=alert C=critical D=debugging M=emergency E=error I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert Temperature 50.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C degrees
The default warning temperatures and the default shutdown temperatures for the FastIron LS are as follows:
For the FLS624:
- Warning temperature is 62C (exhaust side)
- Shutdown temperature is 68C (exhaust side)
For the FLS648:
- Warning temperature is 58C (exhaust side)
- Shutdown temperature is 62C (exhaust side)
To change the temperature at which the device sends a warning, enter a command such as the following at the Privileged EXEC level of the CLI:
FLS648 Switch# temperature warning 47
The can be 0 – 125.
The default values for the FastIron LS are as follows:
For the FLS648:
- Warning temperature is 58C (exhaust side)
- Shutdown temperature is 62C (exhaust side)
For the FLS624:
- Warning temperature is 62C (exhaust side)
- Shutdown temperature is 68C (exhaust side)

To change the shutdown temperature, enter a command such as the following at Privileged EXEC level of the CLI:
FLS648 Switch# temperature shutdown 57
The can be 0 – 125.
The software reads the temperature sensor and polls other hardware sensors according to the value set for the poll time, which is 60 seconds by default. You can change the poll time using the CLI.
To change the poll time, enter a command such as the following at the global CONFIG level of the CLI:
FLS648 Switch(config)# chassis poll-time 200
The can be 0 – 65535.
You can display the amount of the management module’s CPU in use. To do so, enter the following command at any level of the CLI:
FLS648 Switch# show cpu
31 percent busy, from 3248 sec ago 1 sec avg: 31 percent busy 5 sec avg: 31 percent busy 60 sec avg: 31 percent busy 300 sec avg: 31 percent busy
The FastIron switch requires minimal maintenance for its hardware components. Foundry recommends cleaning the fiber-optic connectors on a fiber-optic port and the connected fiber cable each time you disconnect the cable.
Otherwise, you can replace the following hardware components as needed:
The 1-port and 10-Gigabit Ethernet modules are optional. You can order the FastIron LS with a 10-Gigabit module installed at the factory, or you can later upgrade your device.
This section provides the steps for installing, removing, and replacing the 10-Gigabit Ethernet module. You will need the following tools to perform these procedures:

Maintaining the FastIron LS Hardware
Figure 5.1 Installing the Device in a rack mount

To install an optional module into the switch, do the following:
You can remove an SFP or XFP from a port and replace it with a new one while the FastIron LS is powered on and running.
This section provides information about the following tasks:

You can remove a fiber SFP (also called a mini-GBIC) or an XFP from a port while the FastIron LS is powered on and running.
Before removing a fiber optic module, have the following on hand:
To remove a fiber optic module from a Gigabit Ethernet or 10-Gigabit Ethernet port, do the following:
You must install a fiber optic module (SFP or XFP transceiver) in each Gigabit Ethernet and 10-Gigabit Ethernet fiber port you want to use.
You can install a new fiber optic module in a port while the FastIron LS is powered on and running.
Before installing one of these modules into the port, have the following on hand:
To install a fiber optic module, do the following:
Bail Latch

Maintaining the FastIron LS Hardware
To cable a fiber optic module, do the following:
To avoid problems with the connection between the fiber optic module (SFP (mini-GBIC) or XFP) and the fiber cable connectors, Foundry strongly recommends cleaning both connectors each time you disconnect and reconnect them. In particular, dust can accumulate in the connectors and cause problems such as reducing the optic launch power.
To clean the fiber cable connectors, Foundry recommends using the fiber-optic reel-type cleaner that shipped with your FastIron LS. You can also purchase this type of cleaner from the following Website:
http://www.fisfiber.com/Home_Page.asp
When not using an SFP or XFP connector, make sure to keep the protective covering on.
You can configure your Foundry device to monitor XFPs in the system either globally or by specified port. If monitoring is enabled, console messages, syslog messages, and SNMP traps are sent when XFP operating conditions warrant and a port is enabled.
To configure all XFP ports for optical monitoring, use the following command:
To configure a specific XFP port for optical monitoring, use the following command:
FLS648 Switch(config)#interface ethernet 1/1 FLS648 Switch(config-if-e10000-1/1)#optical-monitor
To configure a range of XFP ports for optical monitoring, use the following command:
FLS648 Switch(config)#interface ethernet 1/1 to 1/2 FLS648 Switch(config-mif-e10000-1/1-1/2)#optical-monitor
The optional variable sets the interval in minutes between which alarms or messages are sent. The default interval is 3 minutes.
You can view the XFP optical monitoring information using the show optic command as shown:
FLS648 Switch(config)#optical-monitor

FLS648 Switch#show optic 4
Port Temperature Tx Power Rx Power Tx Bias Current + 4/1 30.8242 C -001.8822 dBm -002.5908 dBm 41.790 mA Normal 4/2 31.7070 C -001.4116 dBm -006.4092 dBm 41.976 mA Normal 4/3 30.1835 C -000.5794 dBm 0.000 mA Normal Low-Alarm Normal Low-Alarm 4/4 0.0000 C 0.000 mA Normal
For Temperature, Tx Power, Rx Power, and Tx Bias Current, values are displayed along with one of the following status values: Low-Alarm, Low-Warn, Normal, High-Warn or High-Alarm. The thresholds that determine these status values are set by the manufacturer of the XFPs. Table 5.2 describes each of these status values.
Low-Alarm Monitored level has dropped below the "low-alarm" threshold set by the XFP manufacturer.
Low-Warn Monitored level has dropped below the "low-warn" threshold set by the XFP manufacturer.
Normal Monitored level is within the "normal" range" set by the XFP manufacturer.
High-Warn Monitored level has climbed above the "high-warn" threshold set by the XFP manufacturer.
High-Alarm Monitored level has climbed above the "high-alarm" threshold set by the XFP manufacturer.
NOTE: This function takes advantage of information stored and supplied by the XFP device. This information is an optional feature of the Multi-Source Agreement standard defining the XFP interface. Not all component suppliers have implemented this feature set. In such cases where the XFP device does not supply the information, a “Not Available” message will be displayed for the specific port that the device is installed
The following media are currently available and supported by FastIron GD and LS devices:
Status Value Description

Maintaining the FastIron LS Hardware
The show media command displays module information including link length, vendor name, vendor part number, vendor revision, and laser wavelength.
Use this command to configure monitoring for all ports (system-wide), a range or ports, or a single port. The variable sets the interval in minutes between the sending of alarms and messages. The default interval is three minutes. When monitoring is enabled, console messages, syslog messages, and SNMP traps are sent when warranted by optical operating conditions, and a port is enabled.
This command displays optical monitoring information as a result of the optical-monitor configuration command. Information includes:
Status values are:
high-alarm



Diagnosing Switch Indicators
Power LED is Off • Internal power supply is disconnected.
Power LED is Amber • Internal power supply has failed. Contact Technical Support.
Diag LED is Amber • The switch’s self test has detected a fault.
Link LED is Off • Verify that the switch and attached device is powered on.
(RPS2-EIF) Link LED is Off • The port does not have a valid connection to the switch.
(RPS2-EIF) Link LED is Amber • Primary power supply is active. RPS is on standby.
(RPS2-EIF) Activity LED is Green • Primary power supply is off. RPS is now active
Symptom Action

If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on the unit are unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact Technical Support for assistance.
Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.
You can access the management agent in the switch from anywhere within the attached network using Telnet, a Web browser, or other network management software. However, you must first configure the switch with a valid IP address, subnet mask, and default gateway. If you have trouble establishing a link to the management agent, check to see if you have a valid network connection. Then verify that you entered the correct IP address. Also, be sure the port through which you are connecting to the switch has not been disabled. If it has not been disabled, then check the network cabling that runs between your remote location and the switch.

This chapter contains hardware specifications for the Foundry Networks FastIron LS.
This chapter contains the following information:
Physical dimensions and weight 2-2
Pinouts and Signaling 2-6
AC power supply 2-9
Redundant Power supply specifications
Physical dimensions and weight 2-10

The following sections present the hardware specifications for the FastIron LS.
Table 0.3 lists the physical dimensions and weight for the FastIron family of switches.
Platform Height Width Depth Weight
FLS624 1.7 in 4.34 cm 17.32 in 44 cm 12.93 in 32.84 cm • 10 lbs (4.52 kg)
Platform Height Width Depth Weight
FLS648 1.7 in 4.34 cm 17.32 in 44 cm 12.93 in 32.84 cm • 10.9 lbs (4.94 kg)
FLS-1XG 86.2g (3.04 oz)
XFP 108.6g (3.83 oz)
For optimal performance, operate or store your Foundry device in compliance with the following environmental conditions.
Table 0.6 provides the operating environment specifications for the FastIron LS.
Operating Temperature Relative Humidity Operating Altitude
32° – 104° F (0° – 50° C) 5 to 95%, @ 121.9°F (50° C), non- condensing
Platform Weight

Table 0.7 provides the storage environment specifications for the FastIron LS.
Storage Temperature Storage Humidity Storage Altitude
-40° to 158° F, -40° to 70° C 95% maximum, non-condensing 10,000 feet (3,000 meter) maximum
Table 0.8 provides the intitial MTBF result for the FastIron LS (including the Power Supply Unit).
Platform Temperature System Failure Rate System MTBF
FLS624 25° C (76.9° F) 6,154.453471 162,484
FLS648 25° C (76.9° F) 6,672.450037 149,870
Cooling
The cooling fans cool the CPU, main memory, and voltage regulators. The fans use either a push or pull configuration to move the air from the left side of the device to the right side of the device.
The following illustration shows the airflow for the device.
Hardware Specifications · Air exhaust · Air inlet

Chassis side Fan Speed 1 Fan Speed 2 Fan Speed 3
Front 31.6 db 48.2 db 48.7 db
Right side 32.3 db 49.1 db 49.4 db
Left side 31.2 db 46.2 db 46.3 db
Back 31.2 db 47.6 db 47.9 db
Chassis side Fan Speed 1 Fan Speed 2 Fan Speed 3
Front 28.8 db 47.1 db 47.8 db
Right side 31.0 db 53.2 db 53.0 db
Left side 29.2 db 49.8 db 49.8 db
Back 27.6 db 43.8 db 44.9 db

Table 0.11 lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency approvals for the FastIron family of switches.
Emissions:
Immunity:
Safety:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense.
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Hardware Specifications · Certifications

This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

The FastIron family of switches come with a 5-year limited lifetime warranty.
This section lists the pinouts for the DB-9 connector and RJ-45 port jacks.
The Console port is a standard male DB-9 connector, as shown in Figure 0.1.
Figure 0.1 Serial port pin and signalling details
Most PC serial ports require a cable with a female DB-9 connector. However, terminal connections will vary, requiring a cable with either a DB-9 or DB-25 connector, male or female.
Serial cable options between the FastIron LS and a PC or terminal are shown in Figure 0.2.

Figure 0.2 Console Port Pin Assignments Showing Cable Connection Options to a Terminal or PC
DB-9 to DB-9 Female Switch
DB-9 to DB-25 Female Switch
Figure 0.3 Pin assignment and signalling for 10/100BaseTX and 1000BaseT ports
100BaseTX and 1000BaseT 10BaseT MDI-X ports
Pin Assignment Pin Number
1 2 3 4 5 6 7 8
RD+ RD- TD+ Not used
1 2 3 4 5 6 7 8
TDCMT
Not used Not used
Cable Specifications
Table 0.12 lists the cable specifications for the cables used with the 10/100, Gigabit and 10-Gigabit Ethernet ports.
Cable Type1 Connector Type Core Diameter (microns)
Modal Bandwidth (MHz*km) or Wavelength (nm)
1000Base-BX-D Single-mode Fiber (SMF)
LC connector for SFP module
9 1490 nm 2 – 10000 (10km)

Cable Type1 Connector Type Core Diameter (microns)
Modal Bandwidth (MHz*km) or Wavelength (nm)
1000Base-BX-U SMF LC connector for SFP module
9 1310 nm 2 – 10000 (10km)
1000Base-LHA SMF LC connector for SFP module
9 1550 nm 2 – 70000 (70km)
1000Base-LHB SMF LC connector for SFP module
9 1550 nm 2 – 120000 (120km)
1000Base-LX Multi-mode Fiber (MMF)
LC connector for SFP module
62.5 500 2 – 550
MMF 50 500 2 – 550
SMF 9 1300 nm 2 – 10000
1000Base-SX MMF LC connector for SFP module
62.5/125 200 .5 – 275
MMF 50/125 900 .5 – 595
MMF 50/125 1500 .5 – 740
MMF 50/125 2000 .5 – 860
1000Base-SX 2 MMF LC connector for SFP module
62.5 500 up to 2000 (2 km)
1000Base-T Copper RJ-45 jack for standard unshielded twisted pair (UTP/ Category 5)
n/a n/a up to 100 meters
100Base-BX SMF LC connector for SFP module
9 1310/1490 10000 (10 km)
100Base-FX MMF LC connector for SFP module
62.5 500 up to 2000 (2 km)
100Base-FX-IR MMF SC 62.5 125 2 km (1.24 miles)
100Base-FX-LR SMF SC 9 125 20 km (12.43 miles)
100Base-TX Copper RJ-45 jack for standard unshielded twisted pair (UTP/ Category 5)
n/a n/a up to 100 meters
Range (meters)

Cable Type1 Connector Type Core Diameter (microns)
Modal Bandwidth (MHz*km) or Wavelength (nm)
10GBase-ER SMF LC connector for XFP module
9 1550 nm up to 40000 (40 km)
10GBase-LR SMF LC connector for XFP module
9 1310 nm 2 – 10000 (10km)
10GBase-SR MMF LC connector for XFP module
62.5/125 160 2 – 26
MMF 50/125 400 2 – 66
MMF 50/125 500 2 – 82
MMF 50/125 2000 2 – 300
10GBase-ZR SMF LC connector for XFP module
9 1550 nm up to 80000 (80 km)
10GBase-ZRD SMF LC connector for XFP module
9 1530.33 – 1561.42 nm up to 80000 (80 km)
10GBase-CX4 4X Twinax IB4X n/a n/a 15 m (49.21 ft.)
The FastIron LS switches include an integrated AC power supply:
Input voltage range 100 - 240 VAC 100 - 240 VAC
Input current < 3 Amps < 3 Amps
Inrush current < 8.5 Amps peak maximum
< 12 Amps peak maximum
Power consumption (without modules)
Power consumption (with all modules)
Max output power 156 W 156 W
Hardware Specifications · Range (meters) · Property FLS624 FLS648

All of the FastIron devices ship with US-compatible power cords unless otherwise specified at the time of order. United Kingdom- and European-compatible power cords are also available.
This section contains the following information for the optional Redundant Power Supply (RPS2-EIF).
The optional Redundant Power Supply (RPS2-EIF) can supply backup power to four attached switches (FLS627 or FLS648) in the event of an AC loss or the failure of an internal power supply in an attached unit.
For more information, see “Installing a Redundant Power Supply” on page 3-8.
Key features of the RPS2-EIF power supply are follows:
Power Supply Dimensions Weight
RPS2-EIF 1.69 in (H) x 17.32 in (W) x 12.72 in (D)
12.1 lb (5.5 kg)
4.3 cm (H) x 44.0 cm (W) x 32.3 cm (D)

Power Supply Input Connector Properties
RPS2-EIF IEC socket 216C743-07)
This section contains regulatory standards for the power supplies, including the following:
The power supplies comply with the conducted and radiated test and immunity standards as listed in Table 0.16. EMC standards are within a 6 dB minimum margin.
Power Supply EMC Standards Immunity Standards
RPS2-EIF • ICES-003, Electromagnetic Emission
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
Hardware Specifications

harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense.
Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

The FastIron LS power supplies comply with the following safety standards:
The power supplies are marked with an electrical hazard label and with the safety warnings shown in Table 0.17.
CUIDADO: Partes adentro no reparables por el operador. Refiera reparo a personal autorizado.
Property RPS2-EIF

Operating temperature 32° to 110° F, 0° to 45° C
Operating altitude up to 6,600 feet above sea level
Storage temperature -40° to 158° F, -40° to +70° C
Storage altitude up to 15,000 feet above sea level
Cooling internal fan, 28 mm, 9500rpm
Table 0.19 provides the intitial MTBF result for the RPS2-EIF (including the Power Supply Unit).
Platform Temperature System Failure Rate System MTBF
RPS2-EIF 25° C (76.9° F) 7343.584745 136,173
Electrical Specifications
This section lists the electrical specifications for the power supply.
Input voltage range 100 - 240 VAC
Input current < 10 Amps
Inrush current 60 A
Hardware Specifications · Operating relative humidity · Property RPS2-EIF



U.S.A.
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
English Translation of above statement
This Class A digital apparatus complies with Canadian ICES-003.
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
English Translation of above statement This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
September 2007 © 2007 Foundry Networks, Inc. A - 1

A - 2 © 2007 Foundry Networks, Inc. September 2007

The cautions and warnings that appear in this manual are listed below in English, German, French, and Spanish.
A caution calls your attention to a possible hazard that can damage equipment.
"Vorsicht" weist auf eine mögliche Beschädigung des Geräts hin. Sie finden die folgenden Vorsichtshinweise in diesem Handbuch.
Une mise en garde attire votre attention sur un risque possible d'endommagement de l'équipement. Ci-dessous, vous trouverez les mises en garde utilisées dans ce manuel.
Un mensaje de precaución le advierte sobre un posible peligro que pueda dañar el equipo. Las siguientes son precauciones utilizadas en este manual.
risque de dépasser 50o C (121o F).
MISE EN GARDE: Vérifiez que rien ne restreint la circulation d'air devant, derrière et sur les côtés du dispositif et
qu'elle peut se faire librement.
September 2007 © 2007 Foundry Networks, Inc. B - 1

aura un circuit redondant en cas de panne d’un des circuits.
CAUTION: Ensure that the device does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all devices installed on the same circuit as the device. Compare this total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the input power connectors.
VORSICHT: Stromkreise, Verdrahtung und Überlastschutz dürfen nicht durch das Gerät überbelastet werden. Addieren Sie die Nennstromleistung (in Ampere) aller Geräte, die am selben Stromkreis wie das Gerät installiert sind. Somit können Sie feststellen, ob die Gefahr einer Überbelastung der Versorgungsstromkreise vorliegt. Vergleichen Sie diese Summe mit der Nennstromgrenze des Stromkreises. Die Höchstnennströme (in Ampere) stehen normalerweise auf der Geräterückseite neben den Eingangsstromanschlüssen.
câblage et la protection de surintensité. Pour déterminer le risque de surcharge des circuits d'alimentation, additionnez l'intensité nominale (ampères) de tous les dispositifs installés sur le même circuit que le dispositif en question. Comparez alors ce total avec la limite de charge du circuit. L'intensité nominale maximum en ampères est généralement imprimée sur chaque dispositif près des connecteurs d'entrée d'alimentation.
PRECAUCIÓN: Verifique que el instrumento no sobrecargue los circuitos de corriente, el cableado y la protección para sobrecargas. Para determinar la posibilidad de sobrecarga en los circuitos de suministros, añada las capacidades nominales de corriente (amp) de todos los instrumentos instalados en el mismo circuito que el instrumento. Compare esta suma con el límite nominal para el circuito. Las capacidades nominales de corriente máximas están generalmente impresas en los instrumentos, cerca de los conectores de corriente de entrada.
cette commande sur un système que vous avez déjà configuré, elle efface la configuration. Si vous effacez la configuration par accident sur un système configuré, entrez la commande write memory pour enregistrer la configuration actuelle dans le fichier startup-config.
B - 2 © 2007 Foundry Networks, Inc. September 2007

MISE EN GARDE: Ne laissez jamais d'outils à l'intérieur du châssis.
MISE EN GARDE: Si vous n’installez pas de module dans un slot, vous devez laisser le panneau du slot en
place. Si vous faites fonctionner le châssis avec un slot découvert, le système surchauffera.
MISE EN GARDE: Pour éviter tout risque d'électrocution, ne pas ouvrir cet appareil lorsqu'il est sous tension.
d'alimentation continue n'ont pas été connectés aux commutateurs devant être alimentés.
d'alimentation continue n'ont pas été connectés aux commutateurs devant être alimentés.
CAUTION: Ensure that the device does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all devices installed on the same circuit as the device. Compare this total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the input power connectors.
September 2007 © 2007 Foundry Networks, Inc. B - 3

instable ou qu'il ne risque pas de tomber.
Placez le dispositif le plus lourd en bas et le plus léger en haut, en plaçant tous les dispositifs progressivement de bas en haut du plus lourd au plus léger.
complètement l'alimentation du dispositif.
cordon d'alimentation fourni avec le dispositif pour le connecter à la source d'alimentation.
September 2007 © 2007 Foundry Networks, Inc. B - 5

assurez-vous d'utiliser un cordon d'alimentation portant la marque de l'organisation responsable de la sécurité qui définit les normes et régulations pour les cordons d'alimentation dans votre pays. Cette marque vous assure que vous pouvez utiliser le cordon d'alimentation avec le dispositif en toute sécurité.
ADVERTENCIA: Si la instalación requiere un cordón de corriente distinto al que se ha suministrado con el instrumento, verifique que usa un cordón de corriente que venga con la marca de la agencia de seguridad que defina las regulaciones para cordones de corriente en su país. Esta marca será su garantía de que el cordón de corriente puede ser utilizado con seguridad con el instrumento.
ohm.
étanche. Il est recommandé d'installer les unités d'alimentation stabilisée dans un rack.
pour éviter tout risque d'instabilité et de chute.
B - 6 © 2007 Foundry Networks, Inc. September 2007
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Power LED is Off | • Internal power supply is disconnected. • Check connections between the switch, the power cord, and the wall outlet. • Contact Technical Support. | p.53 | |
| Power LED is Amber | • Internal power supply has failed. Contact Technical Support. | p.53 | |
| Diag LED is Amber | • The switch’s self test has detected a fault. • Power cycle the switch to try and clear the condition. If the condition persists, contact Technical Support. | p.53 | |
| Link LED is Off | • Verify that the switch and attached device is powered on. • Be sure the cable is plugged into both the switch and corresponding device. • Verify that the proper cable type is used and its length does not exceed specified limits. • Check the adapter on the attached device and cable connections for possible defects. Replace the defective adapter or cable if necessary. | p.53 | |
| (RPS2-EIF) Link LED is Off | • The port does not have a valid connection to the switch. • Check connections between the switch, the power cord, and the wall outlet. | p.53 | |
| (RPS2-EIF) Link LED is Amber | • Primary power supply is active. RPS is on standby. | p.53 | |
| (RPS2-EIF) Activity LED is Green | • Primary power supply is off. RPS is now active | p.53 |