Installation Guide

2100 Gold Street P.O. Box 649100 San Jose, CA 95164-9100
Tel 408.586.1700 Fax 408.586.1900 www.foundrynetworks.com
February 2003

Copyright © 2003 Foundry Networks, Inc. All rights reserved.
No part of this work may be reproduced in any form or by any means – graphic, electronic or mechanical, including photocopying, recording, taping or storage in an information retrieval system – without prior written permission of the copyright owner.
The trademarks, logos and service marks ("Marks") displayed herein are the property of Foundry or other third parties. You are not permitted to use these Marks without the prior written consent of Foundry or such appropriate third party.
Foundry Networks, BigIron, FastIron, IronView, JetCore, NetIron, ServerIron, TurboIron, IronWare, EdgeIron, the Iron family of marks and the Foundry Logo are trademarks or registered trademarks of Foundry Networks, Inc. in the United States and other countries.
F-Secure is a trademark of F-Secure Corporation. All other trademarks mentioned in this document are the property of their respective owners.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
You may use unshielded twisted-pair (UTP) cable for RJ-45 connections—Category 3 or greater for 10 Mbps connections, Category 5 for 100 Mbps connections and Category 5 or 5e for 1000 Mbps connections. Use 50/125 or 62.5/125 micron multimode fiber optic cable, or 9/125 micron single-mode cable, for SFP transceiver connections.
Contact Foundry Networks at:
Foundry Networks Inc. 2100 Gold Street P.O. Box 649100 San Jose, CA 95164-9100
This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/

68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on.
Ne regardez jamais le laser tant qu’il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu’ils sont sous tension.
DE CLASSE I
Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind.
ÄT
Underwriters Laboratories Compliance Statement

Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt 70 dB(A) oder weniger.

Chapter 1 About This Guide 1-1
Audience 1-1 Nomenclature 1-1 How to Get Help 1-1
Foundry Networks Technical Support 1-2 Web Access 1-2 E-mail Access 1-2 Telephone Access 1-2 Warranty Coverage 1-2 Related Publications 1-2
Chapter 2 About the Switch 2-1
Overview 2-1
Switch Architecture 2-2 Management Options 2-2 Description of Hardware 2-4
RJ-45 Ports 2-4 Port Status LEDs 2-5 Power Supply Receptacle 2-7 Features and Benefits 2-8
Connectivity 2-8 Performance 2-9 Management 2-9
Chapter 3 Network Planning 3-1
Introduction to Switching 3-1 Application Example 3-2 Connectivity Rules 3-2

1000 Mbps Gigabit Ethernet Collision Domain 3-2 Application Notes 3-4
Chapter 4 Installing the Switch 4-1
Selecting a Site 4-1 Equipment Checklist 4-2
Package Contents 4-2 Optional Rack-Mounting Equipment 4-2 Mounting 4-3
Rack Mounting 4-3 Desktop or Shelf Mounting 4-4 Connecting to a Power Source 4-5
Chapter 5 Making Network Connections 5-1
Connecting Network Devices 5-1 Twisted-Pair Devices 5-1
Cabling Guidelines 5-1 Connecting to PCs, Servers, Hubs and Switches 5-2 Wiring Closet Connections 5-3 Fiber Optic Devices 5-5
Appendix A Troubleshooting A-1
Diagnosing Switch Indicators A-1 Power and Cooling Problems A-2 Installation A-2 In-Band Access A-2
Appendix B Cables B-1
Specifications B-1 Twisted-Pair Cable and Pin Assignments B-2
10BASE-T/100BASE-TX Pin Assignments B-2 Straight-Through Wiring B-4 Crossover Wiring B-4

1000BASE-T Pin Assignments B-5 1000BASE-T Cable Requirements B-6 Cable Testing for Existing Category 5 Cable B-6 Adjusting Existing Category 5 Cabling B-6 Console Port Pin Assignments B-7
DB-9 Port Pin Assignments B-7 Console Port to 9-Pin DTE Port on PC B-7 Console to 25-Pin DTE Port on PC B-8
Appendix C Specifications C-1
Physical Characteristics C-1
Base Unit C-1 Management Features C-3 Standards C-3 Compliances C-4
CE Mark C-4
Index



Audience
This guide is for system administrators with a working knowledge of network management.
You should be familiar with switching and networking concepts.
This guide uses the following typographical conventions to show information:
Italichighlights the title of another publication and occasionally
emphasizes a word or phrase.
codeshows text that must be entered exactly as it appears in this
guide.
emphasizes an important fact or calls your attention to a dependency.
If you need assistance, Foundry Networks is committed to ensuring that your investment in our products remains cost-effective by offering a variety of support options.
February 2003 © 2003 Foundry Networks, Inc. 1-1

Foundry Networks technical support will ensure that the fast and easy access that you have come to expect from your Foundry Networks products will be maintained.
Point your browser to the following URL: http://www.foundrynetworks.com
Navigate to Services/Technical Support.
Click the Login button, then enter your user name and password to gain access to the Foundry support site.
Technical requests can also be sent to the e-mail address:
◆ !"#$%&&' ( )* +
◆ , - ( *#. +
Contact Foundry Networks using any of the methods listed above for information about the standard and extended warranties.
Refer to the Foundry EdgeIron User Guide for instructions on how to configure and manage the switch.
1-2 © 2003 Foundry Networks, Inc. February 2003

Overview
This switch is an ideal solution for delivering Internet access to individual users in multi-dwelling or multi-tenant units (MDUs/ MTUs), such as apartment housing blocks, commercial buildings or hotels. This switch provides rate-limitable connections to individual users with secure port-to-port isolation between users – all with conventional Ethernet cabling and adapters. At an MDU/MTU site, up to 24 other switches can be cascaded from one switch, providing broadband Internet access for up to 24 individual users on each switch.
Figure 2-1. Front and Rear Panels
Port Status Indicators (1-24) On Amber: 10 Mbps link Flashing Amber: 10 Mbps link/activity On Green: 100 Mbps link Flashing Green: 100 Mbps link/activity
System Indicators PWR, Diag, Stack
Media Slots Combo Gigabit Ethernet ports RJ-45/SF
Console Port Use this port for console connection Module Status Indicators (25/26)
10/100 Mbps RJ-45 Ports
On Amber: 10/100 Mbps link Flashing Amber 10/100 Mbps link/activity On Green: 1000 Mbps link Flashing Green: 1000 Mbps link/activity
February 2003 © 2003 Foundry Networks, Inc. 2-1
100-240V~ 50/60Hz, 2A · Power Socket

The switch contains 24 10/100 Mbps Fast Ethernet ports on the front panel. Each port can provide a dedicated link directly to an end-user PC, or be attached to another Ethernet switch/hub at the end-user’s premises and used as a shared link. The switch completely eliminates the bottlenecks of dial-up internet access by offering a configurable bandwidth of up to 100 Mbps full duplex for each end-user connection. For all port connections, the switch’s 8.8 Gbps bandwidth capacity is more than enough to handle even the most demanding environments.
Auto-negotiation is used to select the optimal transmission speed and communication mode for each connection. With store-and-forward switching and flow control, maximum data integrity is always maintained, even under heavy loading.
This switch includes two port: 1000BASE-SX and RJ-45. These ports allow users the flexibility to use either fiber or copper media.
The switch also supports a stacking module that can be installed into slot M1. The stacking module allows up to eight units to be linked together and managed from one unit using one IP address.
This switch contains a comprehensive array of LEDs for “at-a-glance” monitoring of network and port status. It also includes a management agent that allows you to configure or monitor the switch using its embedded management software, or via SNMP applications. To manage the switch, you can make a direct connection to the RS-232 console port (out-of-band), or you can manage the switch through a network connection (in-band) using Telnet, the on-board Web agent, or Windows-based network management software.
2-2 © 2003 Foundry Networks, Inc. February 2003

The management agent provides a wide range of advanced performance-enhancing features. Port-based VLANs provide traffic security and efficient use of network bandwidth. QoS priority queueing ensures the minimum delay for moving real-time multimedia data through the switch. Flow control eliminates the loss of packets due to bottlenecks caused by port saturation. Port security is provided to filter unwanted traffic from the switch.
Some of the switch’s advanced features are described below. For a detailed description, refer to the Foundry EdgeIron User Guide.
This switch supports up to 255 VLANs. A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network. By segmenting your network into VLANs, you can:
This switch supports Private VLANs as an extension of the common VLAN. Private VLANs can be used to provide port-based security and isolation between ports within a VLAN.
Private VLANs deliver per port security, requiring only one VLAN on every switch, not every port. This feature greatly
February 2003 © 2003 Foundry Networks, Inc. 2-3
VLANs

minimizes the total number of VLANs required. Private VLANs and normal VLANs can exist simultaneously in the same switch.
Specific multicast traffic can be assigned to its own VLAN to ensure that it does not interfere with normal network traffic and to guarantee real-time delivery by setting the required priority level for the designated VLAN. The switch uses IGMP Snooping.
This switch provides Quality of Service (QoS) by prioritizing each packet based on the required level of service, using four distinct categories with Weighted Round Robin queuing. It uses IEEE 802.1p and 802.1Q tags to prioritize incoming traffic based on input from the end-station application. These functions can be used to provide independent priorities for delay-sensitive data and best-effort data.
The switch base unit contains 24 10BASE-T/100BASE-TX RJ-45 ports. All of these ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs. (See “10BASE-T/100BASE-TX Pin Assignments” on page -2.)
Each of these ports support IEEE 802.3x auto-negotiation, so the optimum transmission mode (half or full duplex), and data rate (10 or 100 Mbps) can be selected automatically, if this feature is also supported by the attached device. If a device connected to one of these ports does not support auto-negotiation, the correct speed will be sensed by the port, but the transmission mode will default to half duplex.
2-4 © 2003 Foundry Networks, Inc. February 2003
Multicast Switching · Traffic Priority

Each port also supports auto-negotiation of flow control, so the switch can automatically prevent port buffers from becoming saturated.
The base unit also includes a display panel for key system and port indications that simplify installation and network troubleshooting. The LEDs, which are located on the front panel for easy viewing, are shown below and described in the following tables.
Figure 2-2. Port Status LEDs
Port has established a valid 10 Mbps network connection. Flashing indicates activity.
Port has established a valid 100 Mbps network connection. Flashing indicates activity.
Off There is no valid link on the port.
February 2003 © 2003 Foundry Networks, Inc. 2-5

Port has established a valid 10/100 Mbps network connection. Flashing indicates activity.
Port has established a valid 1000 Mbps network connection. Flashing indicates activity.
Off There is no valid link on the port.
Figure 2-3. System Status LEDs
PWR On Green The unit’s internal power supply is operating normally.
On Amber The unit’s internal power supply has failed.
Off The unit has no power connected.
2-6 © 2003 Foundry Networks, Inc. February 2003

Diag On Green The system diagnostic test has completed successfully.
The system diagnostic test is in progress.
On Amber The system diagnostic test has detected a fault.
Link N/A This indicator is not currently implemented.
Duplex N/A This indicator is not currently implemented.
An initial state of stacking configuration upon powering on.
Green This switch is acting as the master unit in the stack.
Amber This switch is acting as a slave unit in the stack.
When the user enters the light unit command in the CLI, the unit ID of each switch in the stack will be displayed by port LEDs 1 to 8.
The power receptacle is located on the rear panel of the switch. The standard power receptacle is for the AC power cord.
February 2003 © 2003 Foundry Networks, Inc. 2-7

Figure 2-4. Power Supply Receptacle
2-8 © 2003 Foundry Networks, Inc. February 2003
100-240V~ 50/60Hz, 2A

February 2003 © 2003 Foundry Networks, Inc. 2-9

2-10 © 2003 Foundry Networks, Inc. February 2003

Introduction to Switching
A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the most important building blocks for today’s networking technology.
When performance bottlenecks are caused by congestion at the network access point (such as the network card for a high-volume file server), the device experiencing congestion (server, power user or hub) can be attached directly to a switched port. And, by using full-duplex mode, the bandwidth of the dedicated segment can be doubled to maximize throughput.
When networks are based on repeater (hub) technology, the maximum distance between end stations is limited. For Ethernet, there may be up to four hubs between any pair of stations; for Fast Ethernet, the maximum is two. This is known as the hop count. However, a switch turns the hop count back to zero. So subdividing the network into smaller and more manageable segments, and linking them to the larger network by means of a switch, removes this limitation.
A switch can be easily configured in any Ethernet or Fast Ethernet network to significantly boost bandwidth while using conventional cabling and network cards.
February 2003 © 2003 Foundry Networks, Inc. 3-1

Application Example
This switch is specifically designed for delivering Internet access to individual users in multi-dwelling or multi-tenant units (MDUs/MTUs), such as apartment housing blocks, commercial buildings or hotels. Some features of this application are described below.
When adding hubs (repeaters) to your network, please follow the connectivity rules listed below for Ethernet, Fast Ethernet, or Gigabit Ethernet. However, note that because switches break up the path for connected devices into separate collision domains, you should not include the switch or connected cabling in your calculations for cascade length involving other devices.
Maximum Fiber Optic Cable Distance for 1000BASE-SX
Fiber Size Fiber Bandwidth Maximum Cable Length
62.5/125 micron 160 MHz/km 2-220 m (7-722 ft)
200 MHz/km 2-275 m (7-902 ft)
50/125 micron 400 MHz/km 2-500 m (7-1641 ft)
500 MHz/km 2-550 m (7-1805 ft)
Maximum Fiber Optic Cable Distance for 1000BASE-LX
Fiber Size Fiber Bandwidth Maximum Cable Length
9/125 micron N/A 2 m - 5 km (7 - 16404 ft)
3-2 © 2003 Foundry Networks, Inc. February 2003

Maximum Cable Distance for 1000BASE-T
Type Connector Maximum Cable Length
Cat. 5, 5e, or 6 100-ohm UTP RJ-45 100 m (328 ft)
Maximum Cable Distance for 10/100BASE
Type Cable Type Maximum Cable
10BASE-T Twisted Pair, Categories 3, 4, 5 100 m (328 ft)
100BASE-TX Category 5 100-ohm UTP or STP 100 m (328 ft)
February 2003 © 2003 Foundry Networks, Inc. 3-3
Length

Application Notes
However, power budget constraints must also be considered
when calculating the maximum cable length for your specific environment.
3-4 © 2003 Foundry Networks, Inc. February 2003

Selecting a Site
Switch units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location.
February 2003 © 2003 Foundry Networks, Inc. 4-1

suppressor is recommended.
After unpacking the switch, check the contents to be sure you have received all the components. Then, before beginning the installation, be sure you have all other necessary installation equipment.
If you plan to rack-mount the switch, be sure to have the following equipment available:
4-2 © 2003 Foundry Networks, Inc. February 2003

Mounting
A switch unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow.
Before rack mounting the switch, pay particular attention to the following factors:
To rack-mount devices:
February 2003 © 2003 Foundry Networks, Inc. 4-3

Figure 4-1. Attaching the Brackets
Figure 4-2. Installing the Switch in a Rack
4-4 © 2003 Foundry Networks, Inc. February 2003
100BASE-FX Singlemode Module · 100BASE-FX Singlemode Module

Figure 4-3. Attaching the Adhesive Feet
To connect a device to a power source:
February 2003 © 2003 Foundry Networks, Inc. 4-5

Figure 4-4. Power Receptacle
For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the receptacle type in your country.
4-6 © 2003 Foundry Networks, Inc. February 2003
100-240V~ 50/60Hz, 2A

C ONNECTIONS
Connecting Network Devices
The switch may be connected to 10 or 100 Mbps network cards in PCs and servers, as well as to Ethernet and Fast Ethernet hubs and switches. It may also be connected to remote devices using the optional fiber optic modules.
Each device requires a shielded or unshielded twisted-pair (STP or UTP) cable with RJ-45 connectors at both ends. For 1000BASE-T Category 5 or 5e cable is required, for 100BASE-TX connections, Category 5 cable is required; for 10BASE-T, Category 3, 4 or 5 cable can be used.
A twisted-pair connection between two ports must have a crossover of the transmit and receive wires to be able to function. This crossover can be implemented in either of the ports, or in the cable connecting them.
Network card ports in PCs and servers do not contain an internal wiring crossover, these are known as straight-through (MDI) ports. Therefore, most switch and hub ports implement a built-in
February 2003 © 2003 Foundry Networks, Inc. 5-1

crossover — known as fixed crossover (MDI-X) ports — so that they can be connected to PCs and servers using standard straight-through cable. Some switches and hubs also have an MDI port, so that they can connect to another switch’s/hub’s MDI-X port using straight-through cable. To connect between two switches/hubs that only have fixed MDI-X ports, the wiring crossover must be implemented in the cable — known as a crossover cable.
The RJ-45 ports on the switch base unit support automatic MDI/ MDI-X operation, which means that they automatically detect the wiring in the link and configure as MDI or MDI-X accordingly. So for these ports, you can use standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches, hubs, or routers). However, note that auto-negotiation must be enabled on these ports for automatic wiring configuration to function properly.
Do not plug a phone jack connector into an RJ-45 port. This will damage the switch. Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards.
5-2 © 2003 Foundry Networks, Inc. February 2003

Figure 5-1. Making Twisted-Pair Connections
When connected to a shared collision domain (such as a hub with multiple workstations), switch ports must be set to half-duplex mode.
Today, the punch-down block is an integral part of many of the newer equipment racks. It is actually part of the patch panel. Instructions for making connections in the wiring closet with this type of equipment follows.
February 2003 © 2003 Foundry Networks, Inc. 5-3


5-4 © 2003 Foundry Networks, Inc. February 2003

Fiber Optic Devices
An optional slide-in 1000BASE-SX, 1000BASE-LX, or 1000BASE-X transceiver may be used for backbone and long distance connections, or for ISP (Internet) connections. A 1000BASE-SX, 1000BASE-LX, or 1000BASE-X transceiver may also be for connecting to a high-speed server.
Each single-mode fiber optic port requires 9/125 micron multimode fiber optic cabling with an SC connector at both ends. Each multimode fiber optic port requires 50/125 or 62.5/125 micron multimode fiber optic cabling with an SC connector at both ends.
../ 01/ 2 3/ .
/ 03/..40 2$/ &5 ./2 0/ 3 6 . / / /03 .3
February 2003 © 2003 Foundry Networks, Inc. 5-5

Figure 5-3. Making SC Port Connections
5-6 © 2003 Foundry Networks, Inc. February 2003
100BASE-FX Singlemode Module · SC fiber connector

Diagnosing Switch Indicators
February 2003 © 2003 Foundry Networks, Inc. A-1
Troubleshooting Chart · Symptom Action

Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on the unit are unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective.
Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.
You can access the management agent in the switch from anywhere within the attached network using Telnet, a Web browser, or other network management software. However, you must first configure the switch with a valid IP address, subnet mask, and default gateway. If you have trouble establishing a link to the management agent, check to see if you have a valid network connection. Then verify that you entered the correct IP address. Also, be sure the port through which you are connecting to the switch has not been disabled. If it has not been disabled, then check the network cabling that runs between your remote location and the switch.
A-2 © 2003 Foundry Networks, Inc. February 2003

The management agent accepts up to four simultaneous Telnet sessions. If the maximum number of sessions already exists, an additional Telnet connection will not be able to log into the system.
February 2003 © 2003 Foundry Networks, Inc. A-3

A-4 © 2003 Foundry Networks, Inc. February 2003

C ABLES
Specifications
Cable Types and Specifications
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP 100 m (328 ft) RJ-45
1000BASE-SX 50/125 or 62.5/125 micron core MMF
See the following table
1000BASE-LX 9/125 micron SMF 5 km (3.12 miles) SC
1000BASE-T Cat. 5, 5e 100-ohm UTP 100 m (328 ft) RJ-45
Fiber Diameter Fiber Bandwidth Maximum Cable Length
62.5/125 micron MMF
160 MHz/km 2-220 m (7-722 ft)
200 MHz/km 2-275 m (7-902 ft)
50/125 micron MMF 400 MHz/km 2-500 m (7-1641 ft)
500 MHz/km 2-550 m (7-1805 ft)
February 2003 © 2003 Foundry Networks, Inc. B-1
1000BASE-SX Fiber Specifications

Twisted-Pair Cable and Pin Assignments
DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards.
For 10BASE-T/100BASE-TX connections, a twisted-pair cable must have two pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be red and the other, red with white stripes. Also, an RJ-45 connector must be attached to both ends of the cable.
Each wire pair must be attached to the RJ-45 connectors in a specific orientation. (See “Cabling Guidelines” on page -1 for an explanation.)
The figure below illustrates how the pins on the RJ-45 connector are numbered. Be sure to hold the connectors in the same orientation when attaching the wires to the pins.
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Category 3, 4 or 5 cable for 10 Mbps connections or 100-ohm Category 5 cable for 100 Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
The RJ-45 ports on the switch base unit support automatic MDI/ MDI-X operation, you can use straight-through cables for all
B-2 © 2003 Foundry Networks, Inc. February 2003

network connections to PCs or servers, or to other switches or hubs. The RJ-45 port on the 100BASE-TX module is an MDI-X port, which allows you to use straight-through cable for connections to PCs and servers. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3, and 6 at the other end of the cable. For connection to hubs or switches which have MDI-X ports, a crossover cable must be used.
1 Receive Data plus (RD+)
Transmit Data plus (TD+)
2 Receive Data minus (RD-)
Transmit Data minus (TD-)
3 Transmit Data plus (TD+)
Receive Data plus (RD+)
6 Transmit Data minus (TD-)
Receive Data minus (RD-)
4,5,7,8 Not used Not used
February 2003 © 2003 Foundry Networks, Inc. B-3

If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through.
Straight-Through RJ-45 Pin As-
End 1 End 2
2 (RD-) 2 (TD-)
3 (TD+) 3 (RD+)
6 (TD-) 6 (RD-)
Crossover Wiring
If the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be implemented in the wiring.
Crossover RJ-45 Pin Assign-
End 1 End 2
2 (TD-) 6 (RD-)
3 (RD+) 1 (TD+)
6 (RD-) 2 (TD-)
B-4 © 2003 Foundry Networks, Inc. February 2003
signments · ments

1000BASE-T Pin Assignments
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports require that all four pairs of wires be connected. Note that for 1000BASE-T operation, all four pairs of wires are used for both transmit and receive.
Use 100-ohm Category 5 or 5e unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
MDI Signal Name MDI-X Signal Name
1 Transmit Data plus (TD1+)
Transmit Data plus (TD2 +)
2 Receive Data minus (RD1-)
Receive Data minus (RD2-)
3 Transmit Data plus (TD2+)
Transmit Data plus (TD1+)
4 Transmit Data plus (TD3+)
Transmit Data plus (TD4+)
5 Receive Data minus (RD3-)
Receive Data minus (RD4-)
6 Receive Data minus (RD2-)
Receive Data minus (RD1-)
7 Transmit Data plus (TD4+)
Receive Data minus (RD3+)
8 Receive Data minus (RD4-)
Receive Data minus (RD3-)
February 2003 © 2003 Foundry Networks, Inc. B-5
Pi · n

1000BASE-T Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable installations, Category 5e (enhanced Category 5) or 6 cable should be used. The Category 5e and 6 specifications include test parameters that are only recommendations for Category 5. Therefore, the first step in preparing existing Category 5 cabling for running 1000BASE-T is a simple test of the cable installation to be sure that it complies with the IEEE 802.3ab standards.
Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified in the ANSI/TIA/ EIA-TSB-67 standard. Additionally, cables must also pass test parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT). These tests are specified in the ANSI/TIA/ EIA-TSB-95 Bulletin, “The Additional Transmission Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”
If your existing Category 5 installation does not meet one of the test parameters for 1000BASE-T, there are basically three measures that can be applied to try to correct the problem:
B-6 © 2003 Foundry Networks, Inc. February 2003

The DB-9 serial port on the switch’s front panel is used to connect to the switch for out-of-band console configuration. The on-board menu-driven configuration program can be accessed from a terminal or a PC running a terminal emulation program. The pin assignments used to connect to the serial port are provided in the following tables.
PC DB9 DTE Pin #
h’s DB9 DTE Pin #
BB 104 RxD (Received Data)
BA 103 TxD (Transmitted Data)
AB 102 SG (Signal Ground) 5 5 7
No other pins are used.
February 2003 © 2003 Foundry Networks, Inc. B-7

Switch’s 9-Pin Se- rial Port
Null Modem PC’s 9-Pin DTE
3 TXD ----------- RXD ----------> 2 RXD
5 SGND ----------- SGND ---------- 5 SGND
No other pins are used.
Switch’s 9-Pin Se- rial Port
Null Modem PC’s 25-Pin DTE
3 TXD ----------- RXD ----------> 3 RXD
5 SGND ----------- SGND ---------- 7 SGND
No other pins are used.
B-8 © 2003 Foundry Networks, Inc. February 2003
Port · · Port

Physical Characteristics
24 10BASE-T/100BASE-TX, with auto-negotiation
2 slots for optional 1000BASE-T, 1000BASE-SX,1000BASE-LX, and 1000BASE-X GBIC modules
100BASE-TX:RJ-45 (100-ohm, UTP cable; Category 5)
10 and 100 Mbps
Full and half duplex
64 Mbyte per system
February 2003 © 2003 Foundry Networks, Inc. C-1

8.8 Gbps
8K MAC address entries
3.08 kg (6 lb 13 oz)
44 x 32.4 x 4.3 cm (17.32 x 12.8 x 1.69 in.)
C-2 © 2003 Foundry Networks, Inc. February 2003

Management Features
Telnet, or SNMP manager
RS-232 DB-9 console port
TFTP in-band, or XModem out-of-band
MIB II (RFC1213), Bridge MIB (RFC 1493, without Static Table)
IEEE 802.3 Ethernet, IEEE 802.3u Fast Ethernet
IEEE 802.1p priority tags
IEEE 802.3ac VLAN tagging
IEEE 802.1D (Bridging)
IEEE 802.3ad Link Aggregation
IEEE 802.1Q VLAN Bridge Management
February 2003 © 2003 Foundry Networks, Inc. C-3

IEEE 802.1x RADIUS user authentication
IEEE 802.3x full-duplex flow control
UDP (RFC 768), IP (RFC 791), TCP (RFC793), TFTP (RFC 783), TELNET (RFC 783), SNMP (RFC 1157), MIB II (RFC 1213), Traps (RFC 1215), Bridge MIB (RFC 1493), RMON (RFC 1757), HTML (RFC 1866), HTTP (RFC 2068), RADIUS (RFC 2618)
Industry Canada Class A
EN55022 (CISPR 22) Class A
C-Tick - AS/NZS 3548 (1995) Class A
CSA/NRTL (CSA 22.2.950 & UL 1950)
TUV/GS (EN60950)
C-4 © 2003 Foundry Networks, Inc. February 2003

10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable.
100BASE-TX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5 UTP cable.
1000BASE-LX IEEE 802.3z specification for Gigabit Ethernet over one strand of 9/125 micron core fiber cable.
1000BASE-LH Gigabit Ethernet over two strands of 9/125 micron core fiber cable.
1000BASE-SX IEEE 802.3z specification for Gigabit Ethernet over two strands of 50/125 or 62.5/125 micron core fiber cable.
1000BASE-T IEEE 802.3ab specification for Gigabit Ethernet over two pairs of Category 5, 5e 100-ohm UTP cable.
Signalling method allowing each node to select its optimum operational mode (e.g., 10 Mbps or 100 Mbps and half or full duplex) based on the capabilities of the node to which it is connected.
February 2003 © 2003 Foundry Networks, Inc. Glossary-1
Auto-Negotiation

The difference between the highest and lowest frequencies available for network signals. Also synonymous with wire speed, the actual speed of the data transmission along the cable.
A condition in which packets transmitted over the cable interfere with each other. Their interference makes both signals unintelligible.
Single CSMA/CD LAN segment.
Carrier Sense Multiple Access/Collision Detect is the communication method employed by Ethernet and Fast Ethernet.
A workstation, server, or other device that does not act as a network interconnection.
A network communication system developed and standardized by DEC, Intel, and Xerox, using baseband transmission, CSMA/ CD access, logical bus topology, and coaxial cable. The successor IEEE 802.3 standard provides for integration into the OSI model and extends the physical layer and media with repeaters and implementations that operate on fiber, thin coax and twisted-pair cable.
A 100 Mbps network communication system based on Ethernet and the CSMA/CD access method.
Glossary-2 © 2003 Foundry Networks, Inc. February 2003

Device that provides a full 100 Mbps bandwidth (or either 10 or 100 Mbps bandwidth with Auto-Negotiation) to each port (LAN segment).
Transmission method that allows switch and network card to transmit and receive concurrently, effectively doubling the bandwidth of that link.
A 1000 Mbps network communication system based on Ethernet and the CSMA/CD access method.
Defines carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications.
IEEE 802.3ab
Defines CSMA/CD access method and physical layer specifications for 1000BASE-T Fast Ethernet.
IEEE 802.3u
Defines CSMA/CD access method and physical layer specifications for 100BASE-TX Fast Ethernet.
IEEE 802.3x
Defines Ethernet frame start/stop requests and timers used for flow control on full-duplex links.
IEEE 802.3z
Defines CSMA/CD access method and physical layer specifications for 1000BASE Gigabit Ethernet.
February 2003 © 2003 Foundry Networks, Inc. Glossary-3
Fast Ethernet Switch · Full Duplex · Gigabit Ethernet

Separate LAN or collision domain.
Light emitting diode used for monitoring a device or network condition.
Length of twisted-pair or fiber cable joining a pair of repeaters or a repeater and a PC.
Local Area Network (LAN)
A group of interconnected computer and support devices.
Media Access Control (MAC)
A portion of the networking protocol that governs access to the transmission medium, facilitating the exchange of data between network nodes.
An acronym for Management Information Base. It is a set of database objects that contains information about the device.
Wire distance between two end stations in the same collision domain.
A connector for twisted-pair wiring.
Ports that are on separate collision domains or LAN segments.
Glossary-4 © 2003 Foundry Networks, Inc. February 2003

Transmission Control Protocol/Internet Protocol (TCP/IP)
Protocol suite that includes TCP as the primary transport protocol, and IP as the network layer protocol.
Unshielded twisted-pair cable.
February 2003 © 2003 Foundry Networks, Inc. Glossary-5

Glossary-6 © 2003 Foundry Networks, Inc. February 2003


problems A-1 location requirements 4-1
M
R
rack mounting 4-3 rear panel receptacles 2-7 RJ-45 ports
agent 2-2 features 2-9, C-3 out-of-band 2-2 SNMP 2-2 Web-based 2-2 MDI-X port 5-2 MIB support C-3 modules
connections 5-1 description 2-4 pinouts B-5 rubber foot pads,
100BASE-TX C-4 slide-in C-4 mounting the switch
SC port connections 5-5 screws for rack mounting 4-2 single-mode fiber optic
in a rack 4-3 on a desktop or shelf 4-4 multicast switching
cables 5-5 site selelction 4-1 SNMP agent 2-2 specifications
IGMP Snooping 2-4 multimode fiber optic
compliances C-4 environmental C-2 physical C-1 power C-2 standards
connections 5-1, 5-5 examples 3-2
compliance C-4 IEEE C-3 status LEDs 2-5 Support, Technical 1-2 surge suppressor, using 4-1 switch architecture 2-2 switching, introduction
specifications C-4 out-of-band management 2-2
package contents 4-2 password
tags, priority 2-4 Technical Support 1-2
support 1-2 pin assignments B-2
console port B-7 DB-9 B-7 port saturation 2-3 ports, connecting to 5-1, 5-5 power, connecting to 4-6 problems,
e-mail 1-2 telephone 1-2 Web 1-2 Telnet A-3 temperature within a
in-band access A-2 power and cooling
Index-2 © 2003 Foundry Networks, Inc. February 2003

switch indicators A-1 twisted-pair connections 5-1
Web-based management 2-2 Weighted Round Robin
February 2003 © 2003 Foundry Networks, Inc. Index-3

Index-4 © 2003 Foundry Networks, Inc. February 2003
Owners and our team usually reply within a day — and your question helps the next person too.