VFN18R VFN24R VFN30R 18", 24", and 30" Remote-Ready EMBER MASTER ™
P
O
F
F
T
O
N
HI
LO
REMOTE
OFF
ON
flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
WARNING: This appliance is for installa- tion only in a solid-fuel burning masonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design- certified for these installations in accor- dance with ANS Z21.11.2. Exceptions: Do not install this appliance in a factory-built fireplace that includes instructions stat- ing it has not been tested or should not be used with unvented gas logs.
formed by a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow sur- face to cool before touching.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Carefully supervise young chil- dren when they are in the room with heater. When using the hand- held remote accessory, keep se- lector switch in the OFF position to prevent children from turning on burners with remote.
You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.
Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
2 105072

PRODUCT FEATURES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.
OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented deco- rative (ANS Z21.60) product by opening the flue damper (non-thermostat operation only).
14. Turn heater off and let cool before servic- ing, installing, or repairing. When using the hand-held remote accessory, make sure the selector switch is in the OFF position. Only a qualified service person should in- stall, service, or repair heater. 15. When using the hand-held remote acces- sory, make sure the selector switch is in the OFF position when you are away from home for long periods of time. 16. This heater must not be connected to any external electrical source. 17. Operating heater above elevations of 4,500 feet may cause pilot outage.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
SAFETY PILOT This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
See Accessories, page 24.
The wall thermostat or hend-held thermo- stat may not be used where vented decora- tive listing is required.
Base Assembly Control Knob
Figure 1 - Ember Master

Confined and Unconfined Space
The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.
The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow for Heater Location, page 5.
4 105072

Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support)
73,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Continued · 5 105072

Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 2 - Ventilation Air from Inside Building
Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Inlet Air Ventilated Crawl Space
Figure 3 - Ventilation Air from Outdoors

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
*Measured at 14" depth
Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or listed vent-free firebox.
Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fire- place cabinet to any combustible ma- terial and wall should follow the dia- gram in Figure 4. Example: The face of a mantel, book- shelf, etc. is made of combustible ma- terial and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 4). Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials. B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.
121/4
101/2
7 8 3/4
51/4
31/2
13/4
1 4 6 8 10 12 14 16 FIREBOX
*Minimum 16 inches from Side Wall
Figure 4 - Minimum Clearance for Combustible to Wall
*See Floor Clearances, page 9.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10. NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Op- eration, page 10.
If Not Using Mantel
You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory. See Figure 5 for minimum clearances.
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace
If Using Mantel · Heat Resistant Material · 8 105072

Underside of Mantel Shelf
In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood.
2 1/2"
All minimum distances are in inches
Determining Minimum Mantel Clearance
Log Set 24"/30" Models
Log Set 24" and 30" Models
16 3/4"
18 1/2"
If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).
Top of Fireplace Opening
Minimum Non- Combustible Material Height
Distances to Underside of Mantel
If minimum clearances in Figure 6, are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clear- ances shown in Figure 7, when using hood.
Figure 6 - Minimum Mantel Clearances Without Using Hood
Underside of Mantel Shelf
2 1/2"
All minimum distances are in inches
Minimum Non- Combustible Material 8" Min.
18" & 24" Models 20"
Top of Fireplace Opening
Distances to Underside of Mantel
Figure 7 - Minimum Mantel Clearances When Using Hood
FLOOR CLEARANCES A. If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8). B. If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combus- tible flooring (see Figure 9).
Combustible Material Combustible Material Hearth
14" Min.
5" Min.
Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring

If your heater is a manually-controlled model, you may use this heater as a vented product. There are three reasons for operat- ing your heater in the vented mode. 1. The fireplace does not meet the clear- ance to combustibles requirements for vent-free operation. 2. State or local codes do not permit vent- free operation. 3. You prefer vented operation.
Manufactured Fireplace Masonry Fireplace
Figure 10 - Attaching Damper Clamp
If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 24). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.
Note: Install optional FHRCT or FHRCT Receiver and Hand-Held Remote Control Kit (see Accessories, pages 24) before in- stalling gas log heater. See installation in- structions included with the kit. 1. Apply pipe joint sealant lightly to male threads of gas fitting. Connect approved flexible gas hose to inlet side of gas control (see Figure 11, page 11). 2. Locate two masonry screws in hard- ware package. 3. Position heater base assembly in fire- place. 4. Place logs in their proper position on heater base. 5. Center heater base and logs front-to- back and side-to-side in fireplace. 6. Carefully remove logs without moving heater base. 7. Mark screw locations through holes in front panel of base (see Figure 12, page 11). If installing in a brick-bottom fire- place, mark screw locations in mortar joint of bricks. 8. Remove heater base from fireplace. 9. Drill holes at marked locations using 3/16" masonary drill bit. 10. Attach base to fireplace floor using masonry screws (in hardware package).
See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Flexible Gas Hose (if allowed by local codes)
Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator
* An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an accept- able alternative to test gauge connection.
We recommend that you install a sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps mois- ture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Masonry Screw Masonry Screw
Figure 12 - Attaching Base to Fireplace Floor
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).
CSA/AGA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap
Approved Flexible Gas Hose (if allowed by local codes)
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Tee Joint Pipe Nipple Cap
* Minimum inlet pressure for purpose of input adjustment. Figure 13 - Gas Connection

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Fig- ure 14). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to gas control (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 14 through 16). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 15).
Pressure Testing gas Supply Piping system
Closed Equipment Shutoff Valve
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was con- nected. 3. Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
Figure 14 - Equipment Shutoff Valve
Equipment Shutoff Valve Gas Control Location
Figure 15 - Checking Gas Joints
Open · Gas Meter · 12 105072

Rear Log (#3) Peg
Groove in Back of Log Groove in Back of Log
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place front logs (#1L and #1R) on top of the grate. Make sure the notches in the bottom of the logs fit over the grate prongs (see Figure 16). Push back of logs flush with metal grate bar. Note: 18" model has only one front log. 2. Rest bottom middle log (#2) behind metal posts on front burner. Make sure the grooves in the bottom of the log fit over the grate. Bring the log forward next to the metal posts. The pegs on the log must be on top (see Figure 17). 3. Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make sure the peg on the log is on top (see Figure 18). 4. Place the top middle log (#4) on the bottom middle log (#2). Make sure the pegs of the bottom middle log fit se- curely in the holes of the top middle log (see Figure 19). 5. Place the crossover log (#5) on the back log and the top middle log. Make sure the peg on the rear log is in the hole in the bottom of the crossover log. The crossover log should fit in the cutout of the top middle log (see Figure 20).
Figure 16 - Installing Front Log (#1)
Figure 18 - Installing Rear Log (#3)
Bottom Middle Log (#2)
Top Middle Log (#4) Hole
Figure 17 - Installing Bottom Middle Log (#2)
Figure 19 - Installing Crossover Log (#4)
Crossover Log (#5) Hole
Figure 20 - Installing Crossover Log (#5)

LIGHTING
4. Press in and turn control knob clock- wise to the OFF position (see Figure 21). 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column 1. If you don’t smell gas, go to the next step. 6. Press in and turn control knob coun- terclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 21). Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system. 7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 15.
Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.
T
O
P
O
F
N
O
F
AUTO OFF ON
H
Selector Switch in OFF Position
Figure 21 - Control Knob and Ignitor Button Location

For wall thermostat operation, follow instruction supplied with thermostat ac- cessory GWMT1. For wall switch opera- tion follow instructions supplied with GWMS2.
Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2a. Set selector switch in the OFF position. 2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to keep from draining battery.
1. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the AUTO position. Note: The burn- ers may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand- held remote control unit. IMPORTANT: Do not leave the se- lector switch in the AUTO position when the pilot is not lit. This will drain the battery. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 sec- onds to assure proper operation.
You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn control knob clockwise to the PILOT position. 2. Use remote control manual OFF button. 3. Set selector switch in the OFF position.
PROCEDURE
GHRC Series Operation: 2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.
Ignitor Electrode Pilot Burner
(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off auto- matically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
Figure 22 - Pilot
Continued · 15 105072

INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down. IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held re- mote control unit will heat up too quickly and turn the heater off. 3. To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
Figure 25 shows a correct pilot flame pat- tern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Figure 25 - Correct Pilot Flame Pattern
Figure 26 - Incorrect Pilot Flame Pattern
Control Knob in On Position Flame Adjustment Knob
N
O
T
F
O
O
P
F
H
ON OFF REMOTE
Selector Switch in Remote Position
Figure 23 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Increases Room Temperature in AUTO Mode
Decreases Room Temperature in AUTO Mode
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Turns Burners On or Off and Allows You to Choose the Auto Setting
Figure 24 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series Only)

CLEANING AND MAINTENANCE
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 30). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Figure 27 shows correct front burner flame pattern. Figure 28 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.
The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 29). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.
Primary Air Inlet Holes
Figure 29 - Injector Holder On Outlet Burner Tube
Figure 27 - Correct Front Burner Flame Pattern
Yellow Tipping At Top of Blue Flame
Pilot Air Inlet Hole
Figure 28 - Incorrect Front Burner Flame Pattern
Figure 30 - Pilot Inlet Air Hole

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
18 105072

POSSIBLE CAUSE
REMEDY
One or both burners do not light after ODS/ pilot is lit
Delayed ignition of one or both burners
Burner backfiring during combustion
Yellow flame in front burner during burner combustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burners are lit
White powder residue forming within burner box or on adjacent walls or furniture
Remote does not function (GHRC and GHRCT Only)
Continued · 19 105072

POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burners are lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Log set cycles to pilot, but room tempera- ture drops to a lower than ideal level before log set comes back on (GHRCT Only)
20 105072

REPLACEMENT PARTS
Btu (Variable) 16,000/26,000 20,000/33,000 21,5000/36,000 Type Gas Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Piezo Piezo Manifold Pressure 3.4" W.C. 3.4" W.C. 3.4" W.C. Inlet Gas Pressure (in. of water)
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated's Technical Service Depart- ment at 1-888-427-8322.
Maximum 10.5" 10.5" 10.5" Minimum* 5" 5" 5"
Shipping Weight 32 lbs. 34 lbs. 36 lbs.
* For purpose of input adjustment
Usually, we will ask you to return the defec- tive part to the factory.
OFF ON
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated's Parts Department at 1-800- 888-2050 for referral information.
TECHNICAL SERVICE
You may have further questions about in- stallation, operation, or troubleshooting. If so, contact Fireplace Manufacturers Incorporated's Technical Service Depart- ment at 1-888-427-8322.
You can also visit DESA International’s technical services web site at www.desatech.com.
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.
Thermopile · 21 105072


22 105072

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual.
KEY PART NUMBERS NO. VFN18R VFN24R VFN30R DESCRIPTION QTY.
1L 105241-01 105241-02 105998-01 Left Front Log (#1L) 1 1R — 105241-03 105999-01 Right Front Log (#1R) 1 2 105243-01 105243-02 106000-01 Bottom Middle Log (#2) 1 3 105245-01 105245-02 106001-01 Rear Log (#3) 1 4 105249-01 105249-02 106002-01 Top Middle Log (#4) 1 5 105247-01 105247-02 106003-01 Crossover Log (#5) 1 6 103779-01 103779-01 103779-01 O.D.S. Pilot 1 7 098249-01 098249-01 098249-01 Nut 6 8 103780-01 103780-01 103780-01 Pilot Bracket 1 9 101330-01 101330-05 101330-06 Front Burner Assembly 1 9-1 101008-01 101008-01 101008-01 Crossover Burner Gasket 1 9-2 101007-01 101007-01 101007-01 Crossover Burner 1 10 100999-04 100999-05 100999-06 Rear Burner Assembly 1 11 103984-01 103984-02 103984-03 Base Assembly and Decal 1 12 098271-01 098271-06 098271-06 Ignitor Cable 1 13 102445-01 102445-01 102445-01 Piezo Ignitor 1 14 103588-01 103588-01 103588-01 Heat Shield 1 15 103782-01 103782-01 103782-01 Valve Bracket 1 16 M12461-26 M12461-26 M12461-26 Screw 5 17 103781-01 103781-01 103781-01 Gas Control 1 18 098264-02 098264-02 098264-02 Male Fitting 1 19 103784-02 103784-02 103784-02 Flame Adjustment Knob 1 20 103784-01 103784-01 103784-01 Control Knob 1 21 103587-01CK 103587-01CK 103587-01CK Switch Plate 1 22 M11084-26 M11084-26 M11084-26 Screw 2 23 099387-12 099387-12 099387-12 Pilot Tube 1 24 100609-01 100609-01 100609-01 Pilot Tube 1 25 101004-11 101004-11 101004-04 Read Burner Injector 1 26 101004-11 101004-08 101004-08 Front Burner injector 1 27 103783-01 103783-01 103783-01 Remote Burner Tube 1 28 099998-01 099998-01 099998-01 Switch 1 29 103284-02 103284-02 103284-02 Wiring Harness 1 30 099918-02 099918-02 099918-02 Pilot Regulator 1 31 M11084-26 M11084-26 M11084-26 Screw 6
100563-01 100563-01 100563-01 Warning Plate 1 103877-01 103877-01 103877-01 Lighting Instructions Plate 1 100565-01 100565-01 100565-01 Warning Plate Fastener 1 100639-01 100639-01 100639-01 Caution Decal 1 101137-02 101137-02 101137-02 Hardware Kit 1 GA6060 GA6060 GA6060 Lava Rock 1
23 105072

WARMER
Purchase these heater accessories from your local dealer. If they can not supply these accessories, call Fireplace Manufacturers Incorporated's Parts Department at 1-800- 888-2050 for referral information. You can also write to the address listed on the back page of this manual.
ON
AUTO
TEMP
OFF
For all models. The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected.
WALL-MOUNT ON/OFF SWITCH - GWMS2 (PART #01997) (Not Shown)
For all models. Allows the gas log heater to be turned on and off with a wall switch.
For all models. Allows the gas log heater to be operated in a manually or thermostati- cally-controlled mode. You can turn the gas log heater on and off without ever leaving the comfort of your easy chair.
DAMPER CLAMP - 02017 (Not Shown)
Permanently opens chimney flue damper for vented operation. Can be used only with non-thermostat accessories.
For all models. Helps deflect heat away from mantel or wall above fireplace. Fits openings 28" to 49" wide.
For all models. Order when additional rock is desired. (3 1/2 lb. bag)
For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control.
24 105072


Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. There is no warranty on the batteries. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA International Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
105072-01 Rev. E 09/01 NOT A UPC