EN
FieldServer logo
Official user manual

FieldServer FS-8700-87

10 pages·116 KB·Computer Drive·PDF·ENDEFRITNLJA
FieldServer FS-8700-87
Table of Contents 16 sections Driver Manual (Supplement to the FieldServer Instruction Manual) · FS-8700-87 SDD16 · APPLICABILITY & EFFECTIVITY · 1. SDD16 Description · … ShowHide
Page 1 of the FieldServer FS-8700-87 user manual — Driver Manual (Supplement to the FieldServer Instruction Manual)
Page 1 · click to enlarge
Page 1
FieldServer FS-8700-87 — Driver Manual (Supplement to the FieldServer Instruction Manual) diagram (page 1)
Fig. 1 · Driver Manual (Supplement to the FieldServer Instruc…

A Sierra Monitor Company

Driver Manual (Supplement to the FieldServer Instruction Manual)

FS-8700-87 SDD16

APPLICABILITY & EFFECTIVITY

Effective for all systems manufactured after May 1, 2001

Driver Version1.03 Document Revision: 6
Page 2 of the FieldServer FS-8700-87 user manual — Driver Manual (Supplement to the FieldServer Instruction Manual)
Page 2 · click to enlarge
Page 2
Page 2 of the FieldServer FS-8700-87 user manual — Driver Manual (Supplement to the FieldServer Instruction Manual)
Page 3 of the FieldServer FS-8700-87 user manual — 1. SDD16 Description
Page 3 · click to enlarge
Page 3

1. SDD16 Description

The SDD16 driver allows the FieldServer to transfer data to and from devices over RS-485 using SDD16 protocol. The FieldServer can only emulate a Client. The SDD16 driver is used to communicate with a digital I/O module model 485SDD16. The current driver only supports reading the status of all sixteen digital input lines. The SDD16 driver in conjunction with the 485SDD16 module allows the FieldServer to sense external On/Off conditions and to control a variety of devices. The SDD16 driver makes use of the data complement mode feature of the 485SDD16 module. In data complement mode the driver and module communicates with double the amount of data bytes to enable better error detection in noisy electrical environments.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Page 4 of the FieldServer FS-8700-87 user manual — 2. Driver Scope of Supply
Page 4 · click to enlarge
Page 4

2. Driver Scope of Supply

2.1. Supplied by FieldServer Technologies for this driver

FieldServer Technologies PART # Description FS-8700-87 Driver Manual.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Page 5 of the FieldServer FS-8700-87 user manual — 3. Hardware Connections
Page 5 · click to enlarge
Page 5

3. Hardware Connections

The FieldServer is connected to the RS-485 SDD16 module as shown below. Configure the RS-485 SDD16 module according to manufacturer’s instructions. Note that the module auto-detects valid baud rates as defined in the client side connections.

!"## $% "#

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Show 30 more labels / short text on this page
· · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
Page 6 of the FieldServer FS-8700-87 user manual — 4.1. Data Arrays
Page 6 · click to enlarge
Page 6

4. Configuring the FieldServer as a SDD16 Client

For a detailed discussion on FieldServer configuration, please refer to the configuration manual for the FieldServer. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” sample files provided with the FieldServer). This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a SDD16 Server. The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for SDD16 communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays” section, the destination device addresses need to be declared in the “Client Side Nodes” section, and the data required from the servers needs to be mapped in the “Client Side Map Descriptors” section. Details on how to do this can be found below. Note that in the tables, * indicates an optional parameter, with the bold legal value being the default.

4.1. Data Arrays

FieldServer FS-8700-87 — 4.1. Data Arrays diagram (page 6)
Fig. 2 · 4.1. Data Arrays

Data_Array_Name Provide name for Data Array Up to 15 alphanumeric characters

Data_Format Provide data format. Each data array can only take on one format.

Number of Data Objects. Must be larger than the data storage area required for the data being placed in this array.

FieldServer FS-8700-87 — 4.1. Data Arrays diagram (page 6)
Fig. 3 · 4.1. Data Arrays

//Data Arrays // Data_Arrays Data_Array_Name, Data_Format, Data_Array_Length Digitals_01, Bit, 16

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Example

Page 7 of the FieldServer FS-8700-87 user manual — 4.3. Client Side Node Descriptors
Page 7 · click to enlarge
Page 7

4.2. Client Side Connection Descriptors

FieldServer FS-8700-87 — 4.2. Client Side Connection Descriptors diagram (page 7)
Fig. 4 · 4.2. Client Side Connection Descriptors

R1-R2 FSx40 Servers FSx20 Servers Baud Specify baud rate 1200, 2400, 4800, 9600 Parity* Specify parity None Data_Bits* Specify data bits 8 Stop_Bits* Specify stop bits 1 Protocol Specify protocol used SDD16 Handshaking* Specify hardware handshaking None Line_Drive_On Time to wait before driving line 0.001s

Port Specify which port the device is connected to the FieldServer

Poll _Delay* Time between internal polls 0-32000 seconds,1 second

// Client Side Connections Connections Port, Baud, Parity, Protocol, Handshaking, Poll_Delay, Line_Drive_On, Line_Drive_Off R1, 9600, None, SDD16, None, 0.100s, 0.001s, 0s

FieldServer FS-8700-87 — 4.2. Client Side Connection Descriptors diagram (page 7)
Fig. 5 · 4.2. Client Side Connection Descriptors

4.3. Client Side Node Descriptors

FieldServer FS-8700-87 — 4.3. Client Side Node Descriptors diagram (page 7)
Fig. 6 · 4.3. Client Side Node Descriptors

Node_Name Provide name for node Up to 32 alphanumeric characters

Node_ID Module address 0-255 (48 is default address on module) Protocol Specify protocol used SDD16

Specify which port the device is connected to the FieldServer

FieldServer FS-8700-87 — 4.3. Client Side Node Descriptors diagram (page 7)
Fig. 7 · 4.3. Client Side Node Descriptors

// Client Side Nodes Nodes Node_Name, Node_ID, Protocol, Port Module_1, 48, SDD16, R1

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Example · Example

Page 8 of the FieldServer FS-8700-87 user manual — 4.4.3. Timing Parameters
Page 8 · click to enlarge
Page 8

4.4. Client Side Map Descriptors

4.4.1. FieldServer Related Map Descriptor Parameters

FieldServer FS-8700-87 — 4.4. Client Side Map Descriptors diagram (page 8)
Fig. 8 · 4.4. Client Side Map Descriptors

Name of Data Array where data is to be stored in the FieldServer

One of the Data Array names from “Data Array” section above

0 to maximum specified in “Data Array” section above

4.4.2. Driver Related Map Descriptor Parameters

FieldServer FS-8700-87 — 4.4.2. Driver Related Map Descriptor Parameters diagram (page 8)
Fig. 9 · 4.4.2. Driver Related Map Descriptor Parameters

One of the node names specified in “Client Node Descriptor” above Data_Type* Data type Flag Length Length of Map Descriptor 1-16 Address Starting digital line number 0 – 15

4.4.3. Timing Parameters

Column Title Function Legal Values Scan_Interval Rate at which data is polled >0.1s

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

Page 9 of the FieldServer FS-8700-87 user manual — RS485SDD16
Page 9 · click to enlarge
Page 9

Map_Descriptor_Name, Scan_Interval, Data_Array_Name, Data_Array_Offset, Function, Node_name, Address, Length

Digital_inputs, 1s, Digitals_0, 0, rdbc, Module_0, 0, 16

be stored.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com

number.

RS485SDD16

from.

will be stored. Offset into

be stored.

4.4.4. Map Descriptor Example.

// Client Side Map Descriptors

Descriptor.

Descriptor.

Show 33 more labels / short text on this page
The number of · digital lines for · which data will · Map Descriptors · starting · digital · The · line · address this · Descriptor will · fetch data · module’s · Map · The · The Map · function is to · read data · continuously · Descriptor’s · Data Array · data will · retrieved · where · Name of the · Data Array · retrieved data · where · The rate at · which data will · be updated for · this Map · Name of this · Map
Page 10 of the FieldServer FS-8700-87 user manual — RS485SDD16
Page 10 · click to enlarge
Page 10
Page 10 of the FieldServer FS-8700-87 user manual — RS485SDD16
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the FieldServer FS-8700-87

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FieldServer FS-8700-87

Be the first to ask — other owners or our team will answer.

Original document

FieldServer FS-8700-87 manual PDF

10 pages·116 KB·Computer Drive·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…