EN
FP Ruys logo
Official user manual

FP Ruys Optimail

92 pages·6.3 MB·Franking machine·PDF·ENDEFRITNLJA
FP Ruys Optimail
Table of Contents 80 sections TM · opti mail NetSet · Franking system · Manual · … ShowHide
TMp.1opti mail NetSetp.1Franking systemp.1Manualp.11 Security noticesp.53 Set up and put into servicep.9Step 1: Extract and check the contents of the packp.10Step 2: Prepare Flexiscalp.12Step 3: Getting Optimail ready to usep.13Step 4: Connect Flexiscale and Optimailp.15Step 5: Enablep.18Step 6: Set up the Franking Machine Type...p.19Step 7: Loading Portop.194 Enable/ disable the Franking System Optimailp.205 Frankerenp.225.1 Calculate Porto with the Flexiscalep.225.1.1 Set up shipping data . .p.225.1.4 Manual introduction of Portop.275.1.5 Manually select/change the shipping method printp.285.3 Date in the france printp.305.3.1 Show datep.305.3.2 Set datep.305.3.3 Print Frankerprint without datep.315.4 Change cost (only with Optimail Plus)p.325.5 Enter and france letterp.336 Special functionsp.356.1 Use quick-choosp.356.2 Test print with the port .0.0' (nulfranking)p.366.3 Using the letter weigher's count functionp.376.4 Emergency solution: use the franking machine without weighing scalep.387 Cost location functionp.407.1 Show cost location datap.407.2 Print cost location overviewp.427.3 Clear cost location datap.438 Show and print registry amountsp.441 Rp.442 Rp.443 Rp.444 Rp.445 Rp.446 Rp.447 Rp.448 Rp.449 Loading port . . NetSetTMp.479.1 Instructions for the Teleset procedurep.479.2 Loadingp.4810 Basic Settingsp.5110.1 Set Clockp.5110.2 Setting the Flexiscale Sound Signalp.5210.3 Set up the Franking Machine Typep.5310.4 Enable/disable automatic mode of print settingp.5410.5 Set the residual amount warning limit value (Optimail Plus only)p.5510.7 Letter weigher Flexiscale tarragep.5710.8 Select/exchange Portotable (not applicable in the Netherlands)p.5811 Maintenance and servicep.5911.1 Cleaningp.5911.2 Replace Inkt ribbon cassettep.6011.3 Replace Porto Modulep.6211.4 Disposal for recyclingp.6312 Error messages and self-help tipsp.6412.1 Notifications and fault codes . .p.6412.2 Error notifications . . letter weigher Flexiscalep.6712.3 Error messages from the Teleset Data Centerp.68C 14 C 23p.68C 26 C 29p.68C 27 C 28p.68E 17 E 19 E 20p.69E 24 E 25p.69E 30 E 32p.69E 40 E 41 E 42p.70E 45 E 46p.70E 50 E 51 E 52p.7012.4 Self-help tipsp.71Appendixp.75Set the modem's line parametersp.75Example 1: Main connection (direct line) with tone methodp.75Example 2: Main connection (direct line) with pulse pick methodp.76Shipping Settings / Abbreviationsp.80Technical datap.83Letters Weigher Flexiscalep.83
Page 1 of the FP Ruys Optimail user manual — TM
Page 1 · click to enlarge
Page 1

optimail NetSetTM, consisting of the letter weigher

There are two versions of the franking machine.

Functions that in the execution Optimail not or only

Quick Reference Card Quick Reference Card gives you an overview of the

This guide contains the safety instructions

preceded by the following signal words and

symbols and text features to improve the text

Titles and information you are particularly interested in

system and error messages etc.) are printed in italics,

A tip gives help or additional suggestions for improvement

limited availability, received an addition

damage to the postage system Optimail or

calculate irregularities at the port or

In this instructions for use, the name

Attention! draws attention to a possible

The following will be given a better orientation:

Read this manual before you use it

Keep these instructions in the

The manual describes the poster system

flexiscale and the poster optimail.

variants • Optimail and the Optimail Plus.

with regard to a possible hazard for

e.g. SYSTEM STARTS . . PLEASE WAIT..

.Optimail • used for both variants.

Display display elements (options,

functions most commonly used.

postage system Optimail will work.

should be careful, appear Half fat.

proximity to Optimail.

(e.g. only with Optimail Plus ).

The work process.

physical injury.

• to express:

symbols:

france.

FP Ruys Optimail — TM diagram (page 1)
Fig. 1
FP Ruys Optimail — TM diagram (page 1)
Fig. 2
FP Ruys Optimail — TM diagram (page 1)
Fig. 3

TM

opti mail NetSet

Franking system

Manual

On this guide

Page 2 of the FP Ruys Optimail user manual — TM
Page 2 · click to enlarge
Page 2
Diagram . .
Diagram . .
Diagram . .
Diagram . .

9-pole interface/connection Optimail

Letter weigher Flexiscale .

3 4 Letters weigher Flexiscale . . Display and keyboard

Press-in (> 2 seconds):

Diagram . .
Diagram . .
Press 1 xback to previous window

back to the start menu

. . service functions (codeword only)

Basic settings and extended functions:

. . means of transmission:

Show 32 more labels / short text on this page
Weighing platform · power unit · Connection · Flexiscal · on/off · . . number values · Enter keys · ." shortcut · Cancel input / wipe output · Selection keys – · Select options · select other options · Arrow = still present · Scale · Selection field · with 4 options · tarrish · auto setup on/off · . . set up/change the franking machine type without function · • turn on/out · current shipping data · Porto · Call option · Weight · Display field for · Port table · (details) · ."
Page 3 of the FP Ruys Optimail user manual — TM
Page 3 · click to enlarge
Page 3

2 Meet the poster system Optimail NetSetTM 8

3 Set up and put into service 11

4 Enable/ disable the Franking System Optimail 22

5 Frankeren 24 5.1 Calculate Porto using the Flexiscale 24 5.1.1 Set shipping data . . (Optimail Plus only) 34 5.5 Enter and france letter 35

6 Special functions 37 6.1 Quick dialing 37 6.2 Test print with the port .0.0' (nulfranking) 38 6.3 Use count function of letter weigher 39 6.4 Emergency solution: use franking machine without weighing scale 40

7 Cost location function (Optimail Plus only) 42 7.1 Display cost location data 42 7.2 Print cost location overview 44 7.3 Clear cost location information 45

8 Show and print the registration amounts 46

Contents 5 · 1 Safety notices 7

Page 4 of the FP Ruys Optimail user manual — TM
Page 4 · click to enlarge
Page 4

9 Loading port . . NetSetTM 49 9.1 Instructions for the Teleset procedure 49 9.2 Load 50

10 Basic Settings 53 10.1 Set the clock 53 10.2 Setting the Flexiscale 54 10.3 Configuring the Franker type 55 10.4 Setting the mode of transmission to/from 56 10.5 Setting the limit value for the residual amount warning (Optimail Plus only) 57 10.6 Set high port value (Optimail Plus only) 58 10.7 Letters Weighting Flexiscale tarrish 59 10.8 Select/change port table (not applicable in the Netherlands) 60

11 Maintenance and service 61 11.1 Cleaning 61 11.2 Replace inktlint cassette 62 11.3 Replacement Portomodule 64 11.4 Waste disposal for recycling 65

12 Error messages and self-help tips 66 12.1 Notifications and error codes . .

Set Outline Parameters for the modem 77 Glossary 81 Shipping Settings / Abbreviations 82 Form . . Quick dial .

Appendix

Page 5 of the FP Ruys Optimail user manual — 1 Security notices
Page 5 · click to enlarge
Page 5

1 Security notices

Optimail is a postage system for letter mail.

Optimail complies with the relevant safety requirements for use in offices. In the interests of your safety, please observe the following instructions.

  • To prepare and put into use the Optimail franking system, go to this manual.
  • Use only the supplied power supply unit, network data transmission cables. Make sure the connection cables are not damaged.
  • Connect the franking machine Optimail only to a grounded 230 V AC voltage socket.
  • Connect the letter weigher Flexiscale only to a 230 V AC socket.
  • Make sure that the sockets for connection of the franking machine and letter weigher are in close proximity to the devices, and that the power plug is always easy to reach.
  • Disable the Flexiscale letter weigher and the Optimail franking machine before inserting or pulling in the data transmission cables.
  • Do not apply data transmission cables during thunderstorm.
  • Disable the Flexiscale and the Optimail poster, before cleaning the franking system or moving to another place.
  • Make sure that no liquids or objects are included in the letter weigher Flexiscale and in the franking machine Optimail. Pull the net plug immediately from the socket if this should happen. Then have the poster system Optimail checked by the Ruys Customer Support employee before you re-use it.
  • Under no circumstances damage the seal in the mailing. The seal may only be removed by the Ruys Customer Support employee to perform maintenance and repair work on Optimail.
  • Trust maintenance and repair work only to competent personnel, who have the necessary permission from Ruys. Otherwise, your right to warranty and admission by TPG Post B.V. will expire. You are responsible for any damage that may result from this.

Security notices 7

Page 6 of the FP Ruys Optimail user manual — 1 Security notices
Page 6 · click to enlarge
Page 6
Diagram . .
Diagram . .

Optimail is a postage system for small quantities of mail.

The Optimail franking system consists of the French hand-held machine Optimail or Optimail Plus and the Brie- venweger Flexiscale. For data transmission between letter weigher and postage machine, the two devices must be permanently connected using a data transmission cable. The use of the poster without the letter weigher is not normally possible.

Method of operation The setting of the poster print port is controlled by the Flexiscale. You will place the letter on the weighing platform and set up the required shipping details (destination, type of service and special services) at Flexiscale.

The Flexiscale determines the weight and calculates the correct porto amount. Porto and number of a suitable shipping mode print will be automatically transferred to the Optimail. A beeping tone reports the end of data transmission. The Optimail displays the new settings on the display.

All other francing settings (e.g. Re-clame stamp) set directly to Optimail.

You only have to put the letter on the landing plate - Optimail grabs it, franks it and throws it ready for dispatch to the right.

The Flexiscale is a scale for letters and packages. The Flexiscale indicates the weight and calculates the required porto amount for items weighing between 3 and 5,000 grams.

The user guidance on the illuminated display will bring you quickly and surely to your desired settings with all functions.

Letters Weigher Flexiscale

Page 7 of the FP Ruys Optimail user manual — 1 Security notices
Page 7 · click to enlarge
Page 7

Meet the poster system Optimail NetSetTM 9

The Flexiscale requests (once again) all the shipping data required for the porto calculation. Every press on a button is attached by the Flexiscale with a short signal (disabled) and for control you will see the current settings for shipping.

Diagram . .
Diagram . .

Weight and porto amount appear in the display as soon as a post item is on the scale. In the case of incomplete entries or non-acceptable combinations, the Flexiscale does not charge a por-to sum or ERROR appears in the display.

Flexiscal . Special functions ♪ Quick picking. Store in memory of

complete shipping settings. . . Manually adjust weight: for mail items

with a permissible maximum weight exceeding 5 kg. . .

stamps (Post post). .

Update When changing the porto/porto- wear you can update your Flexiscale with a new porto module.

Current cost location (Optimail Plus only)

The Optimail posters letters up to a thickness of 5 mm. For thicker mail items print posters that can be glued.

Diagram . .
Diagram . .

At a glance, you will see all the settings for the franking print in the display:

. Porto (frankling) . . Advertising stamp .

The symbolic image of the poster print on the display is a good orientation help.

The poster print symbol can also be found on the keys that set up the poster image. The assigned field is displayed on the corresponding key filled.

Current shipping data · Franking machine Optimail

Page 8 of the FP Ruys Optimail user manual — 1 Security notices
Page 8 · click to enlarge
Page 8

The settings are selected easily and quickly per key pressure. Optimail does not accept an unacceptable input. A beep indicates that the setting is not possible with the imported goods. The previous setting will appear again in the display.

The thermotransfer printing technique provides a suction and non-staining print. The solid ink on the ribbon is heated when passing through the thermohead. At the pressure, liquefied ink penetrates into the envelope paper and remains indelibleally attached. Replacing the ink ribbon cassette is easy, a few actions are enough.

Purest Francing Quick exchange of cassette

NetSetTM With NetSetTM and the built-in modem, you can recharge .. quickly, comfortably and, if necessary, at any time.

With the Optimail Plus you have the following additional functions:

Extensive functions (Optimail Plus only)

. . Individual registration and settlement of the

Postage costs for 9 cost places. . Print cost-place overview. . . Warning in case of insufficient porto reserve.

Page 9 of the FP Ruys Optimail user manual — 3 Set up and put into service
Page 9 · click to enlarge
Page 9

Set up and put into service 11

3 Set up and put into service

The following table shows in steps the trading operations to be carried out for drawing up and putting into service the francing system.

Overview of the use

1. Extract and check contents...
2. Prepare for use of Flexiscal
3. Prepare to use Optimail
4. Connect Flexiscale and Optimail
5. Enable
6. Configure Franker Machine Type...
7. Load Porto

Conditions for the preparation For the arrangement of Optimail, choose a location that meets the following conditions: . . Indoor air temperature 10°C to 40°C

(the best pressure quality is achieved at indoor air temperatures of 15°C to 35°C) . No direct sunlight . . Relative humidity: 15% to 80%

(Condensary-free) .

Page 10 of the FP Ruys Optimail user manual — Step 1: Extract and check the contents of the pack
Page 10 · click to enlarge
Page 10

Step 1: Extract and check the contents of the pack

Keep the package. Use it again, if you ever want to transport Optimail.

  • Open the cardboard box on top.
  • Remove the Flexiscale and its accessories from the packaging.
  • Check that the delivery is complete and undamaged.

Scope of delivery:

1 Letter weigher Flexiscale 2 Power supply unit

Diagram . .
Diagram . .

Letters Weigher Flexiscale · 3 Data transmission cable

Page 11 of the FP Ruys Optimail user manual — Step 1: Extract and check the contents of the pack
Page 11 · click to enlarge
Page 11

Set up and put into service 13

  • Open the cardboard box on top.
  • Remove Optimail and accessories from the packaging.
  • Check that the delivery is complete and undamaged.

Scope of delivery:

1 Franker Optimail 2 Power cord for the Optimail

3 Modem cable 4 Inkt ribbon cassette

5 Keys, 2 pieces 6 Manual and Quick Reference Card

Ruys B.V. is giving you the money. a separate page with the Personal Identification number for your Optimail.

Diagram . .
Diagram . .

Franking machine Optimail

Page 12 of the FP Ruys Optimail user manual — Step 2: Prepare Flexiscal
Page 12 · click to enlarge
Page 12

Step 2: Prepare Flexiscal

Attention! Don't forget to remove the transport protection of cardboard from below the weighing platform. The Flexiscale otherwise provides incorrect weights and port amounts.

Diagram . .
Diagram . .

This way you remove the transport protection:

  • Grab the weighing platform with two hands and pull it evenly.
  • Pull the weighing platform off to the top.
  • Remove the transport protection from cardboard and store it together with other packaging material.
  • Hold the weighing platform with the narrow side facing backwards.
  • Place the weighing platform with its 4 pens in the 4 openings of the housing.
  • Press the weighing platform down on the housing with a light and even pressure. The weighing platform must not block.
  • Place the letter weigher on a fixed, smooth and level surface. Only this way you get correct weighing results.
  • Turn the set legs until Flexiscale is fixed and without tipping on the ground.
Page 13 of the FP Ruys Optimail user manual — Step 3: Getting Optimail ready to use
Page 13 · click to enlarge
Page 13

Set up and put into service 15

Step 3: Getting Optimail ready to use

  • Place the poster on a fixed, smooth and level surface.
Diagram . .
Diagram . .
  • Open the cap of the ink ribbon cassette box by slightly pressing on the release button.

The hood will swell itself until the attack goes up.

Attention! Make sure that the ink ribbon does not wrinkle or rip when it is applied. This way you prevent ink ribbon tears.

Also note that the edges of the ink ribbon do not fold. Folded ink ribbons are thicker and the wrapping of the spent ink tape is therefore prematurely full.

Diagram . .
Diagram . .
  • Remove the included ink ribbon cassette from the package.
  • If the ink ribbon cassette has a transport protection (cardboard strip) remove the conveyor.
Diagram . .
Diagram . .
  • Tighten the ribbon. Turn the white inklint wrap towards the arrow.

Transport security (if any) · Inklintop winding

Page 14 of the FP Ruys Optimail user manual — Step 3: Getting Optimail ready to use
Page 14 · click to enlarge
Page 14
  • Place ink ribbon cassette with the tape pointing down on the landing plate.
Diagram . .
Diagram . .
  • Carefully slide the ink ribbon tape until you hit it. The ink ribbon cassette should simply slide into the holder of the cassette box.

Stickers on the supply plate and in the cassette box provide additional information about placing ink ribbon cassettes.

  • Shut down. The buckle locks palpably.
Page 15 of the FP Ruys Optimail user manual — Step 4: Connect Flexiscale and Optimail
Page 15 · click to enlarge
Page 15

Set up and put into service 17

Step 4: Connect Flexiscale and Optimail

  • Insert the data transmission cable connector for connecting the franking machine into the 9-pole letter weigher interface.
Diagram . .
Diagram . .
  • Connect the data transmission cable to Flexiscale.

9-pole interface for connection to the poster machine

  • Insert the device plug of the power supply unit into the bus at the back of the Flexiscale.
Diagram . .
Diagram . .

Connecting Letters Weigher

Page 16 of the FP Ruys Optimail user manual — Step 4: Connect Flexiscale and Optimail
Page 16 · click to enlarge
Page 16
  • Insert the device plug of the power cord into the mains socket. The mains connection bus is located on the back of Optimail.
  • Insert the modem cable with the device plug into Optimail's modem connection. The modem connection is located on the back of Optimail. The spring on the plug should point towards the side wall.
  • Connect the modem cable to a telephone box.

Connect letters weigher to the franking machine

  • Connect the Flexiscale with the data transmission cable to Optimail's 25-pole interface.
  • Connect the data transmission cable to Optimail.
Diagram . .
Diagram . .
Show 4 more labels / short text on this page
Franking machine Optimail Connect · Net connection Letter weigher connection Modem connection · Power cord Modem cable · Data transmission cable
Page 17 of the FP Ruys Optimail user manual — Step 4: Connect Flexiscale and Optimail
Page 17 · click to enlarge
Page 17

Set up and put into service 19

In accordance with your order, we deliver the modem cable with the connection that is suitable for your telephone installation or with the appropriate adapter.

According to your order, the Optimail is configured for e.g. one of the following types of connection to the telephone line:

– Direct line with tone method

– Direct line with pulse picking method

– Connection via central heating With tone method .

exit line with digit .0.0.10. and pause

– Connection via central heating With pulse picking method .

outbound line with digit/row e.g. .

Further information about the connection types and setting of the external line parameters for the built-in modem can be found on page 77.

  • Connect the Flexiscal power supply unit to a 230 V AC socket.
  • Connect the Optimail only to a grounded 230 V AC voltage.

Maintain grid connection

Page 18 of the FP Ruys Optimail user manual — Step 5: Enable
Page 18 · click to enlarge
Page 18

Step 5: Enable

Attention! If you use Flexiscale and Optimail from a cold environment (i.e. lower than 10 °C) to a warmer transfer: wait at least two hours before you activate the franking machine. The Flexi scale and Optimail adapt to indoor air temperature. Any condensation disappears.

Attention! The Flexiscale is automatically mapped when you enable it. The weighing platform shall not be taxed. The Flexiscale otherwise provides incorrect weights and port amounts.

Diagram . .
Diagram . .
  • Turn the switch on the back of the Flexiscale from I .

As the start routine expires, system information will appear on the display (e.g. the version number of your Flexiscale software). The Flexiscale is being tarred.

The display shows the default setting for porto calculation, possible special services offered at your choice and weight 0 g.

The letter weigher Flexiscale is ready for use.

  • Insert the key into the lock at the back of Optimail.
Diagram . .
Diagram . .
  • Turn the key in horizontal position (= ON).

The Optimail reports with beeping and on the display all indications are visible for a moment.

Enable letter weigher Flexiscale · Default setting · Enable Franking Machine Optimail

Page 19 of the FP Ruys Optimail user manual — Step 7: Loading Porto
Page 19 · click to enlarge
Page 19

Set up and put into service 21

After the self-test, Optimail shows the current date. After ca. 3 seconds change the indication and on the display appears the last set porto amount and the scale symbol .

After switching on, Optimail transfers the available shipping methods to Flexiscale.

Step 6: Set up the Franking Machine Type...

Before using the Optimail franking system, you must set up the type of connected franking machine to the Flexiscale (Chapter 10.3 on page 55).

In order for the Flexiscale to set up, apart from its porto, the appropriate shipping method print on Optimail should be set to ON (Chapter 10.4 on page 56).

Step 7: Loading Porto

Before you can first post with Optimail, you need to load a certain porto reserve in the Optimail. How to load the port, read chapter 9 on page 49.

The minimum and maximum amount for loading the porto is agreed with a contract between the customer and TPG Post B.V.

The Optimail franking system is ready for use.

Page 20 of the FP Ruys Optimail user manual — 4 Enable/ disable the Franking System Optimail
Page 20 · click to enlarge
Page 20

4 Enable/ disable the Franking System Optimail

Attention! The Flexiscale is automatically mapped when you enable it. The weighing platform shall not be taxed. The Flexiscale otherwise provides incorrect weights and port amounts.

Diagram . .
Diagram . .
  • Turn the switch on the back of the Flexiscale from I .

As the start routine expires, system information will appear on the display (e.g. the version number of your Flexiscale software). The Flexiscale is being tarred.

The display shows the default setting for porto calculation, possible special services offered and weight 0 g.

The letter weigher Flexiscale is ready for use.

Rest During operating breaks, the display-ver-light switches off after about 2 1⁄2 minutes. A subsequent entry or placing a postpiece on the weighing scale activates the lighting again.

  • Insert the key into the lock at the back of Optimail.
Diagram . .
Diagram . .
  • Turn the key in horizontal position (= ON).

The Optimail reports with beeping and on the display all indications are visible for a moment.

Enable letter weigher Flexiscale · Default setting · Enable Franking Machine Optimail

Page 21 of the FP Ruys Optimail user manual — 4 Enable/ disable the Franking System Optimail
Page 21 · click to enlarge
Page 21

Enable/disable franking system Optimail 23

After the self-test, Optimail shows the current date. After ca. 3 seconds changes the indication and on the display appears the last set porto- drag and the scale symbol.

The scale symbol means that the franking machine is ready to take over the Flexiscale's port data.

After switching on, Optimail transfers the available shipping methods to Flexiscale.

The Optimail franking system is ready for use.

Rest If Optimail is not used for about one minute, the franking machine switches to time display.

Once the Flexiscale transfers a new porto amount to Optimail, the Optimail is activated again.

You can also activate Optimail with the rest-stand key.

Diagram . .
Diagram . .
  • Set the switch at the rear of the Flexiscale from I .
  • Turn the key in vertical position (= OFF).
  • Take off the key. This way, your Optimail is protected from unauthorized use.

Disable

Page 22 of the FP Ruys Optimail user manual — 5.1 Calculate Porto with the Flexiscale
Page 22 · click to enlarge
Page 22

5 Frankeren

5.1 Calculate Porto with the Flexiscale

5.1.1 Set up shipping data . .

The shipping data is set in the Flexiscale menu, i.e. the Flexiscale offers you the send details for choice at a time and selects the desired setting with each selection key. For example, the Flexiscale requests all data required for the porto calculation in succession.

An arrow on the right side of the display means that there are more than four possible selection options. With the arrow keys you can easily scroll forward or backwards.

You can find an overview of the shipping settings on page 82.

Attention! The Flexiscale is intended for postal items with a maximum weight of 5 kg.

Diagram . .
Diagram . .
  • Put the post piece on the weighing platform.

The Flexiscale indicates the weight.

  • Press the key for about 2 seconds.

The last transmission setting will be deleted. The Flexiscale shows the start menu for the porto calculation.

In the selection field you can see the possible areas of destination ROODPOST, EUROPE, OUTSIDE EUROPE.

PreviewEUROPE
  • Press the selection button for the desired destination zone.

Clear the specified shipping setting · Start menu post calculation · Select Destination

Page 23 of the FP Ruys Optimail user manual — 5 Frankeren
Page 23 · click to enlarge
Page 23

The Flexiscale will record the selection in the display field and switch on to request the shipping mode.

POSTZEGEL is only for the franking with stamps. Stamp consignments may be sent not are franked with a poster.

OTHER you choose, if the Flexiscale does not offer the required shipping data. In such special cases you can enter the amount of the postage directly (Chapter 5.1.4 on page 29).

The view field shows the selected destination zone (abbreviated) and the possible means of sending in the selection field.

PreviewLETTERS
  • Press the selection button for your desired shipping mode.

The following dispatch parameter shall appear in the selection field, depending on the selected zone of destination and dispatch mode.

Choose Standard, Priority of Economy

  • Press the selection button for your desired setting.
PreviewPRIORITY
PreviewMARKINGS AND VOICE DISCLOSURE (Reception notice)

In the display field you will see the selected shipping data and in the selection field, the special TPG senders provided for this purpose (e.g. (') OJ No L

  • Press the selection button for your desired shipping mode.

Franking 25 · Select mode of shipment · Select Special Service

Page 24 of the FP Ruys Optimail user manual — 5 Frankeren
Page 24 · click to enlarge
Page 24

The Flexiscale will record the selection in the view field. In the selection field, the selected shipping mode is marked dark.

You can also choose further shipping methods.

To deactivate one special mode of transmission: Press the corresponding selection key again.

Enter the value for a postpiece

In some cases, the value of the item for the Flexiscale is to be used in calculating the postal amount (e.g. Insured transport) required.

If the item is on the weighing platform (declared weight > 0 grams), the Flexiscale opens a window to enter the value.

  • Enter the value of the postal item in full euro. In the example, this is 400 euros.
  • Confirm the input with the key .

The value must always be indicated in full euro amounts. The maximum allowed value is 5,400 euros.

Port and way of sending for the franking print:

The Flexiscale calculates the postal amount for the item on the weighing platform, based on the data supplied.

Porto and number of an appropriate shipping mode print will be automatically transferred to the Optimail.

A beeping tone reports the end of data transfer. The Optimail displays the new settings in the display.

Weight Current shipping data · Porto amount

Page 25 of the FP Ruys Optimail user manual — 5 Frankeren
Page 25 · click to enlarge
Page 25

The Flexiscale only automatically sets an appropriate mode of transmission on Optimail when the automatic transmission is switched ON (Chapter 10.4 on page 56).

You can also manually set the shipping mode print or change an automatically configured verse-to-do print. You can run this setting for the poster print on the Flexiscale or directly on Optimail.

To set the shipping mode print . Read page 30 . . on Optimail on page 41.

5.1.2 Calculate Porto for a standard letter within the Netherlands (Use default setting)

With the default setting (ROODPOST .BRIEVEN) you can calculate without having to enter any other data the porto amount for standard letters within the Netherlands.

  • Press the button.

The Flexiscale has the default setting.

  • Put the post piece on the weighing platform.

The Flexiscale determines the weight and calculates the correct porto amount.

After switching on, the Flexiscale is always REDPOST .BRIEVEN (standard setting).

Franking 27

Page 26 of the FP Ruys Optimail user manual — 5 Frankeren
Page 26 · click to enlarge
Page 26

5.1.3 Calculating Porto for postal items weighing more than 5 kg

You can also use the Flexiscale to determine the porto amount for items with an eligible maximum weight of more than 5 kg (e.g. Insurance). For such consignments, the Flexiscale allows for the weight to be introduced by means of numerical tests.

  • Set the required shipping data to Flexiscale as you know. In the example, this is REDPOST PAKKETTEN.
  • If required, browse until the INV will appear in the selection field with arrow keys.
  • Press the selection button for INV WEIGHT.
  • Place any object on the weighing platform. The weighing platform must be loaded, i.e. the display must indicate a weight greater than 0 g . Only then will the Flexiscale open the window for weight input and can calculate the porto.
Diagram . .
Diagram . .
  • Enter the weight of the post piece in grams. Example: For a 10 kg poster type in 10000.
  • Confirm the input with the key .

Porto and number of an appropriate shipping mode print will be automatically transferred to the Optimail.

Attention! The manually set weight is not indicated on the display! If the selected dispatching device allows a weight of more than 5 kg, the Flexiscale calculates the porto- drag for each manual weighing. The weight shown on the display is in such cases meaningless.

Page 27 of the FP Ruys Optimail user manual — 5.1.4 Manual introduction of Porto
Page 27 · click to enlarge
Page 27

5.1.4 Manual introduction of Porto

Special cases may occur where the Flexiscale does not offer the required shipping data for the port calculation and therefore cannot carry out any postage. In such a case, you can enter the porto amount with the number keys on the Flexiscale.

  • Press the key for about 2 seconds.
Diagram . .
Diagram . .

The Flexiscale shows the start menu for the porto calculation.

  • Continue browsing with the arrow key.
  • Press the selection button for OTHER.
  • Place the postpiece or any item on the weighing platform. The weighing platform must be loaded, i.e. the display must indicate a weight greater than 0 g . Only then will the Flexiscale open the window for the porto input.
  • Enter the porto amount in cent (maximum 99999 cents).
  • Confirm the input with the key .

The Flexiscale transfers the imported port to Optimail. You can use this port to post.

Franking 29

Page 28 of the FP Ruys Optimail user manual — 5.1.5 Manually select/change the shipping method print
Page 28 · click to enlarge
Page 28

5.1.5 Manually select/change the shipping method print

If no shipping mode print is set or if you want to change the automatically set, use the manual setting on the Flexiscale.

When all shipping data is set to the Flexiscale and the display indicates the postal item's porto amount:

  • Press the button.

The Flexiscale will show all possible shipping methods in the selective window.

If a shipping mode print is already set automatically, it will appear marked darkly.

  • Press the selection button for your desired shipping method print.

On the display, the selected shipping mode print is marked (on dark background). The Flexiscale immediately transfers the information to the poster. A beeping signal reports the data transfer. The shipping mode print is set to frank.

Before you can determine the amount of postage for the next item, please end the selection of verse-to-do print with the button.

Page 29 of the FP Ruys Optimail user manual — 5.1.5 Manually select/change the shipping method print
Page 29 · click to enlarge
Page 29
Diagram . .
Diagram . .

Following your wishes, Francotyp-Postalia will equip the Optimail Plus with up to 9 different advertising stamps, the Opti mail with 1 advertising voice. The available advertising stamp and the assigned numbers can be found as a user indication on Optimail (extractable, front left).

The number for the advertising stamp print set will appear in the relevant field of the poster print symbol.

Franking 31

Page 30 of the FP Ruys Optimail user manual — 5.3.2 Set date
Page 30 · click to enlarge
Page 30

5.3 Date in the france print

The date for the poster print is automatically set by the built-in clock on the current date. You can continue the date for the poster print. Optimail does not allow a far-reaching postage date or an antidating. If you disable the Optimail, the date will be returned to your current date.

5.3.1 Show date

  • Press the button.
Diagram . .
Diagram . .

The displayed date appears when the franking is printed in the poster.

  • The button allows you to terminate the date view. The display shows the amount of porto again.

5.3.2 Set date

  • Enter the day, month and year before the new date with 2 digits each. Example: 160103 for 16 January 2003.
Diagram . .
Diagram . .
  • Confirm the entered date with the key .

You see the set date and in the Franker Print symbol DATE.

  • End the date view with the button. The display shows the amount of porto again.

Optimail does not accept incorrect date input. The last date set will appear again.

Page 31 of the FP Ruys Optimail user manual — 5.3.3 Print Frankerprint without date
Page 31 · click to enlarge
Page 31

5.3.3 Print Frankerprint without date

The Optimail can also delete the date in the poster. For this purpose, take the provisions of TPG Post B. V. In eight.

  • Press the button.
Diagram . .
Diagram . .

Optimail shows the set date.

  • Press the button.

The Optimail returns to the porto view. Short beeping and flashing DATE indicate that the poster print does not contain a date.

  • Press the button. Optimail shows the set date.
  • End the date view with the button. The display shows the amount of porto again.

Franking 33 · Print Date Again

Page 32 of the FP Ruys Optimail user manual — 5.4 Change cost (only with Optimail Plus)
Page 32 · click to enlarge
Page 32

5.4 Change cost (only with Optimail Plus)

Optimail can register and analyse francings according to individual cos-places. In Chapter 7 you will find detailed information on the cost-location function.

To register francings at a cost point:

  • Enter desired cost place number (1-9).
  • Confirm with the key.

The selected cost-place number appears in the M field.

All subsequent francs are registered for this cost base. The cost base will remain set until you choose a new cost point.

Page 33 of the FP Ruys Optimail user manual — 5.5 Enter and france letter
Page 33 · click to enlarge
Page 33

5.5 Enter and france letter

Only when the Flexiscale calculates the port and has transferred it to Optimail, is Optimail released for francing. With the amount of postage indicated, you can post any number of items.

Attention! Incomplete franking, torn ink ribbon and damage of the print head can be prevented with simple preventive measures:

. . You can post letters up to a thickness of 5 mm.

In the case of multi-page letters, the difference in thickness at the place where printing is made may lead to an uneven print. In such a case, Frank the empty envelope or use labels.

. . Use envelopes with as smooth a surface as possible

surface. This gives you an optimal print quality.

. . Make sure there is at the place where the print should be

Don't sit staples or paper clips.

. . Knock the letters before franking with the upper-

On a flat surface. This slides the letter contents up to the top and gives you a smooth surface for an even french print.

Diagram . .
Diagram . .

.

Let go. Larger envelopes (C5, B4) support light.

. . Once the Optimail has grasped the letter, you may

the letter no longer moves or tries to straighten.

Franking 35

Page 34 of the FP Ruys Optimail user manual — 5.5 Enter and france letter
Page 34 · click to enlarge
Page 34

Enter and france letter

Diagram . .
Diagram . .
  • Place the letter on the landing plate: . . the side to be printed points upwards,

address field is visible . . the top should be against the letter guidance side

- Get down!

  • Move the letter towards the arrow as far as Optimail takes hold of the letter.

As soon as the letter sensor recognizes a letter, a waltz prints the letter against ink ribbon and pressure head . The franked letter is cast to the right.

Page 35 of the FP Ruys Optimail user manual — 6.1 Use quick-choos
Page 35 · click to enlarge
Page 35

6 Special functions

6.1 Use quick-choos

Often used shipping settings can also be saved under the number keys 1 to 9 and then called again by pressing a button. Remember that you can only program a shortcut key for the current portotable.

Under the test, in the factory the default setting ROODPOST . You cannot change the default setting.

This way you store shipping data

  • Set the desired shipping details.
  • Press the number key for at least 3 seconds, under which you want to save the shipping data ( ...).

The Flexiscale display shows SNELTOETS PROG.! The specified dispatch setting is stored under the selected number key.

You can override the quick dial memory with a new assignment.

Special functions 37

Page 36 of the FP Ruys Optimail user manual — 6.2 Test print with the port .0.0' (nulfranking)
Page 36 · click to enlarge
Page 36

6.2 Test print with the port .0.0' (nulfranking)

You can test the current print settings using a Test-Print. Set up test staff printing the porto .0.00 .

Diagram . .
Diagram . .
  • Press the button.

The connection to the letter weigher Flexiscale has been interrupted.

  • Press the button.
  • Confirm with the key.

The display indicates the set porto .0.00 .

  • Place an empty envelope, a label or any magazine as you normally do.

The Optimail prints a complete poster with the port .

To be able to re-frank, you need to enable the scale function again:

  • Press the button.
Page 37 of the FP Ruys Optimail user manual — 6.3 Using the letter weigher's count function
Page 37 · click to enlarge
Page 37

6.3 Using the letter weigher's count function

With the counting function you can easily and quickly select the number of identical letters, postcards etc. The Commission's proposal is based on the following principles:

  • Press the button.

The Flexiscale opens the option menu.

  • Press the button for STUKS.

Now follow the directions on the display.

  • Place 10 pieces out of the total quantity of mail items on the weighing platform.
  • Confirm with the key.

The Flexiscale calculates the weight per piece and appears: NUMBER = 10.

  • Now, lay the total amount of letters to count, postcards etc. On the weighing platform.

On the display you can see the number of pieces.

The key or arrow key allows you to exit the counting function.

Special functions 39

Page 38 of the FP Ruys Optimail user manual — 6.4 Emergency solution: use the franking machine without weighing scale
Page 38 · click to enlarge
Page 38

6.4 Emergency solution: use the franking machine without weighing scale

Attention! The amount of the postage and the shipping method are automatically passed on to the franking machine by the scale. The use of the franking machine without the scale is not possible in principle.

However, in the case of technical problems with the scale, a code to be passed by Ruys can also be used without weighing. In this situation, please contact Ruys.

Porto and shipping mode print set directly to the franking machine.

Set Porto to Optimail

  • Enter the desired porto in cent with the number keys.

You can check the entered row on the display.

  • Confirm with the key.

The display indicates the set porto amount with a decimal point.

If after fixing the porto a beep sounds again and on display .HP & postage amount is blinking, the .high port value . Optimail helps you avoid high francerin gene and loss of port.

If you want to post with the set port:

  • Re-confirm the indicated porto amount with the button.

Notification .Huge port value .

Page 39 of the FP Ruys Optimail user manual — 6.4 Emergency solution: use the franking machine without weighing scale
Page 39 · click to enlarge
Page 39

If you have mistakenly set an excess port amount:

  • Type in a new value.
Diagram . .
Diagram . .

How to change the limit for the Mel-ding .High port value .

Special shipping methods provide you with a corresponding print when franking (e.g. The Commission has not yet adopted any measures to prevent the introduction of a new system for the transport of dangerous goods. The available shipping methods and the assigned numbers can be found as a guide to use in Optimail (extractable, front left).

The number for the specified mode of dispatch appears in the relevant field of the franking print symbol.

  • Place the letter on the landing plate and post it.

Special functions 41

Page 40 of the FP Ruys Optimail user manual — 7.1 Show cost location data
Page 40 · click to enlarge
Page 40

7 Cost location function

(Optimail Plus only)

With the cost placement function, Optimail Plus provides you with a tool to record and analyse your postage costs. Nine cost-place memories are available for this. The cost places may be, for example, the departments of an enterprise or separate firm debt holders from a branch complex.

For the francing you simply set up your desired cost base. Optimail stores the number and amount of the francings.

You can call the number and port usage in euro for each cost point separately. If you wish, you can also print a cost-place overview of all the costs.

7.1 Show cost location data

Retrieve consumption at a cost point

  • Enter desired cost place number (1-9).
  • Confirm with the key.

The selected cost-place number appears in the M field.

  • Press the button.

The Optimail indicates the postage costs stored under this cost point since the last time the counter was set to zero (indicative in euro).

Page 41 of the FP Ruys Optimail user manual — 7 Cost location function
Page 41 · click to enlarge
Page 41

Request the number of francings for a cost point

  • Enter desired cost place number (1-9).
  • Confirm with the key.

The selected cost-place number appears in the M field.

  • Press the button.

Optimail shows the number of value frames that have been performed below this cost point since the last time the counter was set to zero. Nulfrankings are not registered.

Cost location function 43

Page 42 of the FP Ruys Optimail user manual — +
Page 42 · click to enlarge
Page 42

7.2 Print cost location overview

The cost-place overview contains the cost location data (consumption and number of items) for all costs places and your Optimail registry records.

Diagram . .
Diagram . .

The Optimail must be disabled.

  • Hold the key and enable Optimail with the key.

+

Diagram . .
Diagram . .
  • Once you see the cost-site display .M0 and printer symbol, let go of the key. The printer symbol indicates that Optimail is ready to print.
  • Place a label or any sheet. Optimail prints the cost-place overview.
  • The key returns to the poster function.

Cost location overview (example)

Page 43 of the FP Ruys Optimail user manual — 7.3 Clear cost location data
Page 43 · click to enlarge
Page 43

7.3 Clear cost location data

If you want to delete data from a cost point, you need to set the consumer and numerator of each item's number back to zero.

Diagram . .
Diagram . .
  • Enter the number of the cost point.
  • Confirm with the key.

The selected cost-place number appears in the M field.

Put the consumer at zero

  • Hold the key down and briefly press the button.
Diagram . .
Diagram . .

The consumer for the cost location set has been erased. Optimail indicates .0.00 . for consumption.

Set countr number of pieces to zero

Diagram . .
Diagram . .
  • Hold the key down and briefly press the button.

The counter number of pieces for the set cost- place has been erased. The Optimail indicates .0.o. pieces.

The cost-place . . Under the cost location .0.0.3., total consumption and number of items from all places of work have been achieved. If the data are deleted from a particular cost location, the relevant values shall be deducted from the cost point .

Cost location function 45

Page 44 of the FP Ruys Optimail user manual — 8 R
Page 44 · click to enlarge
Page 44

8 Show and print registry amounts

Optimail stores important numbers and usage information in registers.

You can print the individual registry amounts on display and as an overview together with cost location analysis.

The following information is stored in the individual registers:

1 R

Fair value . . available euro porto reserve

Consumer . . sum of all euro francings

2 R

Total loaded . .

3 R

Total value of all value fractions (not including nullrankings)

4 R

HP value (Optimail Plus only). . (in euro)

5 R

Limit value (Optimail Plus only). . limit set for the residual amount warning (in euro)

6 R

Status . . information about the machine settings for the technician of customer support

7 R

See you. pieces . . total number of francings (including zero fractioning).

8 R

Page 45 of the FP Ruys Optimail user manual — +
Page 45 · click to enlarge
Page 45

Show and print registry amounts 47

  • Enter register number (1-8).
Diagram . .
Diagram . .
  • Confirm with the key.

The register amount will appear on the display. In the R-field you will see the corresponding registry number.

The button returns to the porto indication.

Print registry amounts with a default Optimail

The Optimail must be disabled.

  • Hold the key and enable Optimail with the key.

+

Diagram . .
Diagram . .
  • Once the printer symbol is displayed on the display, you can release the key. The printer symbol indicates that Optimail is ready to print.

Show registry amounts

Page 46 of the FP Ruys Optimail user manual — 8 Show and print registry amounts
Page 46 · click to enlarge
Page 46
Diagram . .
Diagram . .
  • Place a label or any sheet. Optimail prints the registry overview.

The print looks like the example on page 44. Some of the above mentioned data are of no importance to Optimail users.

The key returns to the poster function.

Print registry amounts to an Optimail Plus

The Optimail Plus summarises the registry amounts and cost location data in the cost-place overview.

How to print the cost-place overview, see section 7.2.

Page 47 of the FP Ruys Optimail user manual — 9.1 Instructions for the Teleset procedure
Page 47 · click to enlarge
Page 47

Load Porto . . NetSetTM 49

9 Loading port . . NetSetTM

9.1 Instructions for the Teleset procedure

NetSetTM is loading the desired porto reserve with modem. The Optimail has an internal modem for this. After the input of the PIN (personal identification number) and the amount you want, Optimail provides the actual loading by a short connection to the Teleset Data Center. The charged porto reserve is calculated according to the contract you have concluded with TPG Post B.V.

Allowed amounts The minimum and maximum amount for loading the porto is agreed with a contract between the customer and TPG Post B.V.

Security • CALL-FP xx • Warnings

For safety reasons, TPG requires that Optimail contact the Teleset Data Center at regular intervals. The Teleset Data Center checks the registers and other values.

If the Call - FPxx notification appears (the FP44, FP45, Fp46, FF47 are possible), it is time to connect with the data center. If no france goods are required at the moment, a coupon of 0.00 euros can be paid.

If you do not respond to this notification, Optimail blocks important functions until the Optimail is connected to the Teleset Data Center.

When the Optimail indicates in the display . . credit-, please contact TPG-NetSetTM service.

Technical designation: While loading, do not use a phone connected to the same telephone box. There may be unnecessary costs if the telephone horn is recorded during loading and is not hung back. The modem cannot terminate the connection.

Page 48 of the FP Ruys Optimail user manual — 9.2 Loading
Page 48 · click to enlarge
Page 48

9.2 Loading

Attention! After 8 attempts to confirm a wrong PIN (Personal Identification Number), Optimail blocks. Only the Ruys Customer Support employee can re-release your Optimail for franking and loading.

  • Check that the Optimail is connected to the telephone line.
  • Turn on the Optimail and wait for the last set porto amount to appear.

Disable Libra Function • Press the button.

The scale symbol on the display disappears. The connection to the letter weigher Flexiscale has been interrupted.

Enter PIN • Type in the 8-position PIN (Personal Identification Number) of your Optimail (in the example .

The PIN for your Optimail can be found on the separate sheet.

  • Confirm the PIN with the key .
Diagram . .
Diagram . .

Optimail is now in Teleset mode. The amount used for the last load is preset (in example EUR 1,000). If you want to load another amount, continue loading with .. .

Start Load

Page 49 of the FP Ruys Optimail user manual — 9.2 Loading
Page 49 · click to enlarge
Page 49

Load Porto . . NetSetTM 51

Keep amount Load the preset amount...

Diagram . .
Diagram . .
  • Confirm the preset amount with the key .

Change the amount Loading another amount...

  • Type in the amount you want (in example 500 euros).
Diagram . .
Diagram . .
  • Confirm the new amount with the key .

Unacceptable amounts/incorrect imports do not accep- tarte Optimail. The last amount used will appear on the display.

Connection Building The display shows the word "Change" and the amount.

Optimail will establish the connection to the Teleset Data Center.

Confirm amount When the Optimail is ready to load, the word .Reset . and the amount that needs loading will appear on the display alternately.

Diagram . .
Diagram . .
  • To actually load the indicated amount, you must confirm it within 30 seconds with the button.

The indication from 30 onwards shows the remaining time in which you need to confirm, so that the amount actually is charged.

Done If a beep sounds and the porto indication appears on the display, the loading is complete. The amount loaded is available as a porto reserve in your Optimail.

Or

Page 50 of the FP Ruys Optimail user manual — 9.2 Loading
Page 50 · click to enlarge
Page 50
  • Check the new residual amount (register 1R). Press the keys and press them in a row.

Help with Teleset errors can be found in chapter 12.3 on page 70.

Until the connection to the Teleset Data Center has been established, you can cancel the procedure:

Wrong input in Teleset mode (e.g. at the time of import) you knew with the button.

You can now repeat the input and continue loading

exit the Teleset mode with the key.

Cancel Load · or

Page 51 of the FP Ruys Optimail user manual — 10.1 Set Clock
Page 51 · click to enlarge
Page 51

10 Basic Settings

10.1 Set Clock

The battery-buffered clock of the franking machine Optimail makes current data available concerning date and time.

The setting of the date and time for the system is controlled by the franking machine. Every time the Optimail franking system is enabled, the Flexiscale letter weigher automatically takes over the date and time setting of the French turntable.

The date and time setting in the Flexiscale option menu is of no significance for the functioning of the Optimail franking system.

This is how you set the time to Optimail

A correction of the time of the built-in clock from the poster Optimail will only occur very rarely.

  • Enter the new time with 2 digits for hours and minutes each. Example: 1420 to 2.20 hours.
  • Confirm the input with the key.

The new time appears on the display along with the clock symbol .

After ca. 2 seconds the porto indication appears again on the display.

You can set the time 5 hours forward or backwards. Optimail does not accept incorrect time input. The last set time is preserved.

Basic Settings 53

Page 52 of the FP Ruys Optimail user manual — 10.2 Setting the Flexiscale Sound Signal
Page 52 · click to enlarge
Page 52

10.2 Setting the Flexiscale Sound Signal

The Flexiscale confirms each key pressure with a beep. You can disable this function.

Diagram . .
Diagram . .
  • Press the button.

The Flexiscale opens the option menu.

  • Press the CONFIGURATION selection button.
  • Press the selection button for SIGNAL.
  • With the corresponding selection key, turn on or off the Audi Q5 signal.
  • Confirm the setting with the button .

The configuration menu will appear again on the display.

  • Leave the configuration menu with the key.
  • Leave the option menu with the key.

The Flexiscale returns to the postage calculation.

Page 53 of the FP Ruys Optimail user manual — 10.3 Set up the Franking Machine Type
Page 53 · click to enlarge
Page 53

10.3 Set up the Franking Machine Type

Before you can start using Flexiscale and Optimail letter weigher together, please set the type of connected franking machine to the Flexiskale.

  • Press the button.
Diagram . .
Diagram . .

The Flexiscale opens the option menu.

  • Press the CONFIGURATION selection button.
  • Press the selection button for SET METER.
  • Press the Optimail selection button.
  • Confirm the setting with the button .

The configuration menu will appear again on the display.

  • Leave the configuration menu with the key.
  • Leave the option menu with the key.

The Flexiscale returns to the postage calculation.

Basic Settings 55

Page 54 of the FP Ruys Optimail user manual — 10.4 Enable/disable automatic mode of print setting
Page 54 · click to enlarge
Page 54

10.4 Enable/disable automatic mode of print setting

The Flexiscale can send the setting of an appropriate shipping method print to Optimail using the set shipping data. You can enable/disable this function.

  • Press the Flexiscale button .

The Flexiscale opens the option menu.

  • Press the selection button for VERZ.CREATION.
  • With the corresponding selection key, switch on or off automatic transmission.
  • Confirm the setting with the button .
  • Leave the option menu with the key.
Page 55 of the FP Ruys Optimail user manual — 10.5 Set the residual amount warning limit value (Optimail Plus only)
Page 55 · click to enlarge
Page 55

10.5 Set the residual amount warning limit value (Optimail Plus only)

The Optimail's .Rest amount warning function responds if the porto reserve is below the set limit. The limit value is set at 100,00 euros.

  • Type in the desired limit value in cents (in example 15000 for a limit value of EUR 150,00).
  • Press the button. The amount disappears from the display.
  • After each other on the keys and press.

Optimail indicates the new limit value (register 6R).

The button returns to the porto indication.

Basic Settings 57

Page 56 of the FP Ruys Optimail user manual — 10.5 Set the residual amount warning limit value (Optimail Plus only)
Page 56 · click to enlarge
Page 56

10.6 Set high port value (Optimail Plus only)

The Optimail's .High port value . (HP) function indicates that the amount of the postage exceeds the specified limit value. By default, the .high port value . is set at 2.00 euros.

  • Type in the desired .High port value .Price in cents (in the example: 300 for a limit of 3.00 euro).
  • Press the button. The amount disappears from the display.
  • Press the button.

The new border amount is stored. The porto indication appears again on the display.

You can make the set .High port value .

Page 57 of the FP Ruys Optimail user manual — 10.7 Letter weigher Flexiscale tarrage
Page 57 · click to enlarge
Page 57

10.7 Letter weigher Flexiscale tarrage

The Flexiscale is automatically mapped at each system start. The Flexiscale is also tarrated during use, as soon as it determines a lower weight (weight

You should only tarrish the Flexiscale yourself if you fix a zero load on an empty weighing platform . for a weighing platform).

This is how you tarrish the Flexiscale

  • Set the basic condition for weighing function (eject weight platform or impose weighing plateau).
  • Press the button.

While the Flexiscale is being mapped, the message NULSTELLEN appears on the display.

Attention! If you use a weighing platform, do not re-use it after tarrish. Otherwise, the Flexiscale registers a lower weight and is automatically mapped. You can therefore obtain incorrect weights and port amounts.

Basic Settings 59

Page 58 of the FP Ruys Optimail user manual — 10.8 Select/exchange Portotable (not applicable in the Netherlands)
Page 58 · click to enlarge
Page 58

10.8 Select/exchange Portotable (not applicable in the Netherlands)

You may have multiple porto tables stored in your Flexiscale.

Change to another portotable

  • Press the key for about 2 seconds.

The Flexiscale shows the start menu for the porto calculation.

  • Press the button.
  • Press the control button for the new porto table (in our example NETSET0104).
  • Confirm the setting with the button .

The Flexiscale now uses the new portotable.

Page 59 of the FP Ruys Optimail user manual — 11.1 Cleaning
Page 59 · click to enlarge
Page 59

Maintenance and service 61

11 Maintenance and service

Attention! The seal on the mailing closure may only be removed by the Ruys Customer Support employee to enable maintenance and repair work.

Maintenance and repair work may only be performed for safety reasons by a Ruys Customer Support employee.

Your poster system is cleaned and maintained once a year by Ruys Technology Services. This is your guarantee for a long-term, non-fault operation.

You can do the following work yourself:

Clean external parts of the housing (Chapter 11.1)

Replace ink ribbon cassette (Chapter 11.2)

.Replace Porto module (Chapter 11.3).

11.1 Cleaning

  • Disable Frankersystem Optimail.
  • Cleaning the enclosure with a lightly moistened cloth.
Page 60 of the FP Ruys Optimail user manual — 11.2 Replace Inkt ribbon cassette
Page 60 · click to enlarge
Page 60

11.2 Replace Inkt ribbon cassette

The message "Cassette" in the display indicates that the ink ribbon cassette should be replaced.

Attention! Use only the original ink ribbon cassing sets of Francotyp-Postalia/Ruys.

Diagram . .
Diagram . .
  • Open the cap of the ink ribbon cassette box by slightly pressing on the release button.

The hood will swell itself until the attack goes up.

  • Pull out the spent ink ribbon cassette forward.
Diagram . .
Diagram . .
  • Remove new ink ribbon cassette from the packaging.
  • If the ink ribbon cassette has a transport protection (cardboard strip) remove the conveyor.

Attention! Make sure that the ink ribbon does not wrinkle or rip when it is applied. This way you prevent ink ribbon tears.

Also note that the edges of the ink ribbon do not fold. Folded ink ribbons are thicker and the wrapping of the spent ink tape is therefore prematurely full.

  • Tighten the ribbon. Turn the white inklint wrap towards the arrow.

Transport security (if any) · Inklintop winding

Page 61 of the FP Ruys Optimail user manual — 11.2 Replace Inkt ribbon cassette
Page 61 · click to enlarge
Page 61

Maintenance and service 63

  • Place ink ribbon cassette with the tape pointing down on the landing plate.
Diagram . .
Diagram . .
  • Carefully slide the ink ribbon tape until you hit it. The ink ribbon cassette should simply slide into the holder of the cassette box.

Stickers on the landing plate and in the cassette box provide additional information about replacing the cassette.

  • Shut down. The buckle locks palpably.
  • Confirm the notification with the key.
Page 62 of the FP Ruys Optimail user manual — 11.3 Replace Porto Module
Page 62 · click to enlarge
Page 62

11.3 Replace Porto Module

As the postal provisions/tariffs of TPG Post B.V. change, update the Flexiscale once by changing the porto module. You can order a current porto module from Ruys.

This is how you replace the porto module

Attention! Disable the postage system Optimail. Interrupt the voltage supply before replacing the porto module.

Diagram . .
Diagram . .
  • Disable the postage system Optimail. Pull the Flexiscal power supply unit out of the socket, just to be safe.
  • Grab the weighing platform with two hands. And pull it up gently.
  • Press the mark of the lid of the porto module and remove the cover to the bottom.
  • Pull the old porto module carefully from the housing upwards.
  • Place the new porto module as shown in the image.
  • Press the porto module down until it hits.
  • Put the lid on the housing. The lid is clicking audiblely.
Page 63 of the FP Ruys Optimail user manual — 11.4 Disposal for recycling
Page 63 · click to enlarge
Page 63

Maintenance and service 65

  • Hold the weighing platform with the narrow side facing backwards.
Diagram . .
Diagram . .
  • Place the weighing platform with its 4 pens in the 4 openings of the housing.
  • Press the weighing platform down on the housing with light and even pressure. The weighing platform must not block.
  • Reconnect the Flexiscale to the net (page 17).
  • Turn on the Optimail franking system.

A series of updating processes are now under way in the Flexiscale. Notifications on the display provide all necessary information.

  • The Flexiscale will then show you information about the new porto table.
  • Confirm this with the key.

If the porto module contains multiple Porto Tables/ Carrier, Flexiscale will continue this routine for each Porto Table.

11.4 Disposal for recycling

If your Optimail ever permanently goes out of service, please observe the legal requirements for environmentally friendly disposal of electronic apps. Our customer support is willing to assist you with advice and deed.

Page 64 of the FP Ruys Optimail user manual — 12.1 Notifications and fault codes . .
Page 64 · click to enlarge
Page 64

12 Error messages and self-help tips

Attention! Do not disassemble parts of the mantle. Have maintenance and repair services carried out by trained personnel. In the case of unexpert repair, the claim to warranty and admission at TPG is compromised.

You can solve minor problems and problems when working with Optimail yourself. In this chapter you will find help and tips for resolving and avoiding malfunctions.

The following service numbers are available:

Service RuysTel. 070 331 5 333
Service TPG-NetSetTMTel. 076 5272727

12.1 Notifications and fault codes . .

Optimail's self-diagnosis system provides you with information about the current state of the machine.

Acoustic signal If the operation is wrong, an acoustic signal (peep tone) will follow.

Optimail does NOT accept the entered value or action.

Error message in display Warnings and failures are indicated by the Optimail with the relevant error messages in the display.

Possible error encodings and the action to be performed can be found in the following overview.

Error Message Possible Cause and Solution

.Service . without error code or symbol: service interval is reached (usually after 15,000 printing).

Page 65 of the FP Ruys Optimail user manual — 12 Error messages and self-help tips
Page 65 · click to enlarge
Page 65

Error messages and self-help tips 67

Diagram . .
Diagram . .

By the codes 01 to 18: Always warn Ruys Customer Support!

Error code 19 briefly appears in the picture: Values are misplaced. Clear all cost location dates or call Ruys Customer Support (Chapter 7.3).

Error code 19 appears and the Optimail blocks: Call Ruys Customer Support!

Diagram . .
Diagram . .

If the malfunction has not been resolved after repeated switching on and off: Call Ruys Customer Support!

If when enable error code 21 appears: When you turned on a post piece, it was already inserted. Remove mail item. Clear the error message using the key.

Attention! Mailpiece jammed! In GEEN If the stuck item is removed by force. The ink ribbon can tear off.

Always solve this malfunction as follows: Press any key (not button !) or disable the Optimail. The Optimail releases the mail. Remove the post piece. Following the cassette, check and if necessary tighten the ribbon (Chapter 11.2).

Page 66 of the FP Ruys Optimail user manual — 12 Error messages and self-help tips
Page 66 · click to enlarge
Page 66

Error Message Possible Cause and Solution

(continuation) If there is no stuck post piece, the cassette has been used.

Press the key, Optimail ends the franking and casts out the franked post piece.

Diagram . .
Diagram . .

Valve of the cassette compartment is not closed properly.

Diagram . .
Diagram . .

Frankertegoed used. The set value cannot be franked.

Attention! Optimail can only be used for 3000 francs or 3 months and then blocks itself.

Loading the last port was too long ago. Port loading (Chapter 9).

Page 67 of the FP Ruys Optimail user manual — 12.2 Error notifications . . letter weigher Flexiscale
Page 67 · click to enlarge
Page 67

Error messages and self-help tips 69

12.2 Error notifications . . letter weigher Flexiscale

Error Message Possible Cause and Solution

ERROR No shipping possible with the selected shipping data: . The selected service is only available in

combination with another service (e.g. For B.V.ONTVST you must also select SIGNS) • Combining the forms mail not

accepted. Check and correct the specified send-off field in the display box.

TEVEL Mailing piece is too heavy (overweight) for the chosen shipping method.

Check and correct the specified send-off field in the display box.

Under Minimum Weight not yet reached.

For INTL.S. LETTER BOOKING, a minimum weight of 2000 g is required.

VALUE Imported value at . .

Correct value.

Overflowing. The scale is overloaded.

Releasing Libra. Apply up to 5 kg.

Page 68 of the FP Ruys Optimail user manual — C 27 C 28
Page 68 · click to enlarge
Page 68

12.3 Error messages from the Teleset Data Center

If a malfunction occurs while loading the france, an error code is displayed. There are two types of error codes:

• transient problems in building the

connection. Error code starts with .

. . errors resulting in the unloading of a load

hebben. Error code starts with .

The connection to the Teleset Data Center (TDC-NL) has been temporarily disrupted. The operation is automatically repeated up to 3x.

Cause Solution To Fix By

C 13 Retry Connection Installed Trying

C 18 Too bad connection Try again

C 14 C 23

No processing in TDC-NL at this time

Try again later

C 26 C 29

Modem has no dial tone, or incorrect pick parameters

Control of telephone lines, control of dialling parameters

C 27 C 28

Called number in call or not answering

C 31 Phone number is

Calling is done automatically with new number

C 39 Inclusion in the

Try again later

TDC-NL not possible at the moment

Show 6 more labels / short text on this page
. · Error- · code · Operator Ruys TPG · Try again · changed
Page 69 of the FP Ruys Optimail user manual — E 30 E 32
Page 69 · click to enlarge
Page 69

Error messages and self-help tips 71

With . . & . .

Trade as follows:

  • Clear key error message.
  • Determining the cause of the disturbance and resolving Ruys Customer Support calls.
  • Restart loading the france goods.

Cause Solution To Fix By

E 16 Modem error, dial parameters

Check connection cable and dial parameters

E 17 E 19 E 20

Internal Error Try Again

E 21 Operator operation terminated

E 24 E 25

E 26 9 electoral failure

E 29 Connection NIET built up within 70 seconds

Checking phone plug, checking dial parameters

E 30 E 32

No processing in TDC-NL at this time

Call Ruys Customer Support

Show 7 more labels / short text on this page
ACTIVE SUBSTANCE (S) codes · Error- · code · Operator Ruys TPG · Repeat operation · Check Fashion Error Connection Cable · see E 16
Page 70 of the FP Ruys Optimail user manual — E 50 E 51 E 52
Page 70 · click to enlarge
Page 70

Cause Solution To Fix By

E 33 Incorrect PIN

Call Ruys Customer Support

entered, machine not logged in

E 34 Optimail Outdoor

Call Ruys Customer Support

E 35 Optimail not yet

Call Ruys Customer Support

E 37 Amount requested

E 40 E 41 E 42

R3=R1+R2 is not correct

Call Ruys Customer Support

E 43 Amount requested

Repeat with new amount, if necessary call TPG-NetSetTM Service

E 44 Maximum

Call Ruys Customer Support

E 45 E 46

Protocol error Bel Ruys Customer Support

E 50 E 51 E 52

Repeat with correct PIN, if necessary call Ruys Customer Support

Show 13 more labels / short text on this page
Error- · code · Operator Ruys TPG · use · released · Call TPG-NetSetTM Service · higher than france credit · E 38 Porto Account · Call TPG-NetSetTM Service · blocked · unacceptable · well achieved · Incorrect PIN entered
Page 71 of the FP Ruys Optimail user manual — 12.4 Self-help tips
Page 71 · click to enlarge
Page 71

Error messages and self-help tips 73

12.4 Self-help tips

Problem Possible cause and solution

...to the letter weigher Flexiscale

The weight values indicated are unrealistic.

Transport security hasn't been removed.

Take the weighing platform and remove the transport protection (page 14).

Flexiscale does not indicate any postal amount for the item.

Incomplete shipping data. Check the display field to make sure that the specified shipping data is complete.

On the display after switching on no indication.

Power supply unit not correctly in the socket. Insert plug power unit correctly into the socket.

Device plug is not correctly located in the Flexiscale connection box. Insert the device plug correctly on the back of the Flexiscale (page 17).

The display shows a weight of > 0 g with empty weighing platform.

Wrong zero.

Re-deadrate with the key.

...to the poster Optimail

Date and/or time not correct. Reset date and/or time (Chapter 5.3 and 10.1).

Display stays empty. No power line. Check the power cord, turn on the machine.

Franking print incomplete/ uneven (incomplete print, especially in the upper part).

Unfavorable location of the letter contents in the envelope.

Note before franking to the top on a flat surface. Please observe the instructions on page 35.

Page 72 of the FP Ruys Optimail user manual — 12.4 Self-help tips
Page 72 · click to enlarge
Page 72

Problem Possible cause and solution

For thicker letters: Franquise an empty envelope or use labels.

(continuation) Franking print incomplete/ uneven.

Franking machine is blocking. Disable the Optimail. Just a moment and turn it back on.

Optimail doesn't post. Frankerte used up well. Loading new france goods (Chapter 9).

Libra function is enabled but no franc value has been transferred yet. Input from the scale.

Cost M0 is set. Set cost location between 1 and 9.

The porto calculated by the Flexiscale must not be franked (postage stamp). Optimail has not been released for franking. Check the shipping settings to the Flexiscale.

The built-in clock has stopped. When enabled . .

Reset date and time. Play this often, call Ruys Customer Support.

Optimail does not take over the france value from Flexiscal.

Data transmission cable not correctly connected. Checking data transmission cable.

Data transmission's been compromised. Disable the Franking Machine and scale, hold on a second.

Letters weigher Flexiscale is not correctly configured.

Type of connected franking machine contro-learn. . Set Optimail • Chapter 10.3.

Page 73 of the FP Ruys Optimail user manual — 12.4 Self-help tips
Page 73 · click to enlarge
Page 73

Error messages and self-help tips 75

Problem Possible cause and solution

Franker is not ready to take the data from the letter weigher.

(continuation) Optimail does not take over the france value from Flexiscal.

Check that Optimail is set correctly for the acquisition of data (e.g. Is the scale symbol shown in the display?). If necessary: re-activate the scale function with the key .

At the scale: clear weighing platform and re-imposition the item.

Optimail does not automatically take over the shipping mode prints.

Automatic mode print setting is disabled.

Activate automatic mode-print setting (Chapter 10.4).

No appropriate means of delivery are available for the selected dispatch mode.

Diagram . .
Diagram . .

Attention! In NO case remove the stuck post piece by force.

Press any button (not the !) or turn off Optimail. The Optimail releases the mail.

Then check the ink ribbon cassette: Remove Inkt ribbon tape and the inkt ribbon ev. Retract (Chapter 11.2).

Page 74 of the FP Ruys Optimail user manual — 12.4 Self-help tips
Page 74 · click to enlarge
Page 74
Page 74 of the FP Ruys Optimail user manual — 12.4 Self-help tips
Page 75 of the FP Ruys Optimail user manual — Example 1: Main connection (direct line) with tone method
Page 75 · click to enlarge
Page 75

Appendix . . Set the modem's external line parameters 77

Appendix

Set the modem's line parameters

The external line parameters for the modem are set when you deliver Optimail to your telephone connection (according to your order).

You can check the set external line parameters and reset them when you change your phone connection. The following examples show the method using four typical types of connection.

Example 1: Main connection (direct line) with tone method

Main connection: To access the public telephone network (outbound line) you do not need a number (e.g. .

You can recognize the tone method by choosing the .

The external line parameters should be set as follows:

Diagram . .
Diagram . .

Outer line parameters

Page 76 of the FP Ruys Optimail user manual — Example 2: Main connection (direct line) with pulse pick method
Page 76 · click to enlarge
Page 76

Example 2: Main connection (direct line) with pulse pick method

Main connection: To access the public telephone network (outbound line) you do not need a number (e.g. .

The pulse pick method is recognized by the .click sounds .d when choosing.

The external line parameters should be set as follows:

Diagram . .
Diagram . .

Outer line parameters

Page 77 of the FP Ruys Optimail user manual — Example 2: Main connection (direct line) with pulse pick method
Page 77 · click to enlarge
Page 77

Appendix . . Set the modem's external line parameters 79

Example 3Connection via the control panel with tone method Outgoing line with digit .0.0.10. and pause

Connection via the mainframe: to access the public telephone network (outbound line) you need a number (e.g. .

You can recognize the tone method by choosing the .

The external line parameters should be set as follows:

Diagram . .
Diagram . .

Outer line parameters

Page 78 of the FP Ruys Optimail user manual — Example 2: Main connection (direct line) with pulse pick method
Page 78 · click to enlarge
Page 78
Example 4Connection via the control unit with pulse pick method Outgoing line with digit .

Connection via the mainframe: to access the public telephone network (outbound line) you need a number/digit row (e.g. .

The pulse pick method is recognized by the .click sounds .d when choosing.

The external line parameters should be set as follows:

Diagram . .
Diagram . .

Outer line parameters

Page 79 of the FP Ruys Optimail user manual — Example 2: Main connection (direct line) with pulse pick method
Page 79 · click to enlarge
Page 79

Appendix . . 81

Glossary Labels Self-adhesive special labels, which you post and can paste on your shipment. Required for large, heavy and thick shipments.

Franking print Franking of mail items for transport by TPG. When franking, Optimail will print the postal amount, place of dispatch with zip code, date, logo and registration number on the envelope. In addition, advertising stamp and means of transmission can be printed.

Modem In the franking machine Optimail built-in electronic unit, allowing data exchange via telephone line.

Franking machine accounting system of TPG POST B.V. When loading, numerical data is exchanged between Optimail and Teleset Data Center via modem, which will release the desired amount of porto. The amount of the post is recovered in accordance with your contract or must be paid in advance.

PIN (Personal identification number)

Ruys B.V. is giving you the money. for your Optimail a PIN. The PIN is the code for loading with the Teleset procedure.

Data center of Ruys B.V. Here the loaded porto is released and the charges are managed. The Teleset Data Center is available 24 hours a day to load via the built-in modem port.

Teleset Data Center (TDC-NL)

Test print Franking with port . This allows you to check the setting for the francing.

NetSetTM (distance charge)

Page 80 of the FP Ruys Optimail user manual — Shipping Settings / Abbreviations
Page 80 · click to enlarge
Page 80

Shipping Settings / Abbreviations

Diagram . .
Diagram . .
Page 81 of the FP Ruys Optimail user manual — Shipping Settings / Abbreviations
Page 81 · click to enlarge
Page 81

Appendix . . Shipping Settings / Abbreviations 83

Diagram . .
Diagram . .
Page 82 of the FP Ruys Optimail user manual — Shipping Settings / Abbreviations
Page 82 · click to enlarge
Page 82
Diagram . .
Diagram . .
Page 83 of the FP Ruys Optimail user manual — Franking machine Optimail
Page 83 · click to enlarge
Page 83

Appendix . . 85

Technical data

Letters Weigher Flexiscale

Dimensions 225 mm x 96 mm x 290 mm (width x height x depth)

Weight c. 2.4 kg

Mains connection 230 V / 50 Hz 50 mA (recorded assets at member Flexiscale)

Rated weight 3 to 5 000 g

Weigh accuracy 0.1% of final value

Environmental conditions +10°C to +40°C

Relative humidity15% to 80%, condensate free

Franking machine Optimail

Dimensions 320 mm x 190 mm x 290 mm (width x height x depth)

Mains connection 230 VAC / 50 - 60 Hz

Power consumption 90 W (in rest: 6 W)

Fiber T 0.5 A at 230 VAC

Settlement method NetSetTM per modem

Show 7 more labels / short text on this page
Indication accuracy 1 gram · . . Display LCD, illuminated · Weight 6,1 kg · Safety Class I · Display LCD, non-enlightened · Printing technique Thermotransfer pressure
Page 84 of the FP Ruys Optimail user manual — Technical data
Page 84 · click to enlarge
Page 84

Environmental conditions +10°C to +40°C

Do not expose to direct sunlight Recommended for the best pressure quality: +15 to +35°C

Noise emission LWA

Ink ribbon cassette c. 1000 Francs Store at 0°C to +32°C, do not expose to direct sunlight

Postal items Thickness up to 5 mm Labels, minimum strip dimensions 45 x 130 mm

Diagram . .
Diagram . .
Page 85 of the FP Ruys Optimail user manual — Declaration of Conformity
Page 85 · click to enlarge
Page 85

Appendix . . 87

Declaration of Conformity

FP Ruys Optimail — Declaration of Conformity diagram (page 85)
Fig. 68 · Declaration of Conformity
Page 86 of the FP Ruys Optimail user manual — Declaration Of Conformity
Page 86 · click to enlarge
Page 86

Declaration Of Conformity

FP Ruys Optimail — Declaration Of Conformity diagram (page 86)
Fig. 69 · Declaration Of Conformity
Page 87 of the FP Ruys Optimail user manual — Technical data
Page 87 · click to enlarge
Page 87
Page 87 of the FP Ruys Optimail user manual — Technical data
Page 88 of the FP Ruys Optimail user manual — Technical data
Page 88 · click to enlarge
Page 88
Page 88 of the FP Ruys Optimail user manual — Technical data
Page 89 of the FP Ruys Optimail user manual — Technical data
Page 89 · click to enlarge
Page 89
Page 89 of the FP Ruys Optimail user manual — Technical data
Page 90 of the FP Ruys Optimail user manual — Technical data
Page 90 · click to enlarge
Page 90

92 Franking machine Optimail . .

Diagram . .
Diagram . .

Operating instructions (extractable, with advertising-stamp and shipping-wise prints)

Diagram . .
Diagram . .

Mainline Connection Modem Connector 25-pole interface for letter weigher connection

Show 7 more labels / short text on this page
Display · Briefing side · Feeder plate · Unlock key (for cap/ink ribbon cassette box) · Cap/inck tape cassette box, behind it ink ribbon tape cassette · Lock with key · Postal closure with seal
Page 91 of the FP Ruys Optimail user manual — Technical data
Page 91 · click to enlarge
Page 91

94 93 Franking machine Optimail . . Display

Fix france fuse

Franking machine Optimail . .

Diagram . .
Diagram . .

Back to post function 3)

1. Function only available on Optimail Plus, buttons without inscription have no function 2) Optimail supports 1 advertising stamp 3) Function . .Stop printing cost/registers . 4) Only as an emergency solution (without Flexiscale) / for zero francturing
Diagram . .
Diagram . .
Amount of remaining warning1)
Servicememory module/

Printer symbol:

.indication with error code,
Errorsystem clock

Consumption of the 1)

Show 30 more labels / short text on this page
Disable letters-/disable · . . setting the limit amount · display · Register · Advertising stamp · without function · setup · ." Register amounts · Porto reserve consumed, · • francing not possible · Porto spare almost used · Promotional stamp 2) · Date · Shipping · mode print · data security measure · Cost places 1) · Number of francs (1) · from the cost place · ♪ Next maintenance · Records · Time indication · cost location · Cost point 1) · and/or · (1... 9) · (1 ... 8) · Register
Page 92 of the FP Ruys Optimail user manual — Ruys Customers
Page 92 · click to enlarge
Page 92

2004-03 / 100 / helbig berlin

51.0019.8207.00 Rev. 01 AE-Nr. 03-7518

95 Ruys Customers Support

Support Every poster system Optimail is pre-

That it leaves the factory thoroughly tested.

quality control still a malfunction

Ask our headquarters about the front

If you are not aware of the problem, please take a look at your system

We have to be careful not to let the Commission down.

contact our Ruys Customers

you responsible Ruys Customers

ManufacturerFrancotyp-Postalia AG & Co. KG

Importer/liverancier: Ruys Handelsvereniging B.V.

Customer SupportTel. 070 331 5 333 Fax 070 331 6 397 e-mail [email protected]

Tel 070 331 5 331 Fax 070 331 6 399 e-mail [email protected]

count070 331 5 315
fax070 331 5 390

internet www.ruys.nl

2500 CC The Hague

Accessorieswww.ruys.nl/supplies

2516 BZ The Hague

Article 4P.O. Box 19100
Service TPG-NetSetTM076 5272727

Support.

Support.

Ruys Customers

Rue de la Grande Beers, 34 · Birkenwerder

Ask about the FP Ruys Optimail

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the FP Ruys Optimail

Be the first to ask — other owners or our team will answer.

Original document

FP Ruys Optimail manual PDF

92 pages·6.3 MB·Franking machine·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…