EN
Fedders logo
Official user manual

Fedders C30ABD1VF

6 pages·172 KB·Air Conditioner·PDF·EN
Fedders C30ABD1VF
Table of Contents 28 sections Split System Air Conditioner · 1 1 ⁄ 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz · Performance: · Efficiency rating of 13 SEER and 14 SEER · … ShowHide
Page 1 of the Fedders C30ABD1VF user manual — Performance:
Page 1 · click to enlarge
Page 1
Fedders C30ABD1VF — Split System Air Conditioner diagram (page 1)
Fig. 1 · Split System Air Conditioner

Split System Air Conditioner

1 1 ⁄ 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz

Fedders C30ABD1VF — Split System Air Conditioner diagram (page 1)
Fig. 2 · Split System Air Conditioner

Performance:

Efficiency rating of 13 SEER and 14 SEER

Cooling capacities from 1 1 ⁄ 2 to 5 tons

Refrigerant Circuit:

Factory installed liquid line filter drier

Long life copper tubes, aluminum fins

State-of-the-art compressors

Large, wrap-around coil surface

Quality Built:

Galvanized steel exterior cabinet with 1,000-hour salt spray, powder-coated finish

Powder-coated fan guard

Full louvered panel to protect coil

Formed base with 2 1 ⁄ 2 " ground clearance

Limited 5-year warranty on parts

Easy To Install:

Factory-charged with R-22 refrigerant

Only three screws to access electrical controls

Easy access to service valves

Rated in Accordance with ARI Standard 210. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org

Model Size Nominal Min. Circuit Max. Fuse or Operating Dimensions Min. Mounting Ship / Operating Number (tons) BTUH Ampacity Breaker H x W x D (inches) Pad Size (inches) Weight (lbs) C18ABD1VF 1 1⁄ 18,000 29.1 1526 1⁄ X 21 1⁄ X 21 1⁄ 2 2 224 x 24 144 / 138 C24ABD1VF 2 24,00011.5 1526 1⁄ X 21 1⁄ X 21 1⁄ 2 2 224 x 24 142 / 136 C30ABD1VF 2 1⁄ 30,000 214.3 2032 1⁄ X 21 1⁄ X 21 1⁄ 2 2 224 x 24 169 / 163 C36ACD1VF 3 36,00018.7 3032 1⁄ X 29 1⁄ X 29 1⁄ 2 2 232 x 32 189 / 180 C42ACD1VF 3 1⁄ 42,000 220.3 3532 1⁄ X 29 1⁄ X 29 1⁄ 2 2 232 x 32 213 / 204 C48ACD1VF 4 48,00023.1 4032 1⁄ X 29 1⁄ X 29 1⁄ 2 2 232 x 32 217 / 208 1 1 C60ACD1VF 5 60,000 30.1 50 39 X 29 ⁄ X 29 ⁄ 32 x 32 230 / 220 2 2C60ACD1VF 5 60,00030.1 5039 X 29 ⁄ X 29 ⁄ 2 232 x 32 230 / 220
Page 2 of the Fedders C30ABD1VF user manual — Split System Air Conditioner
Page 2 · click to enlarge
Page 2
Fedders C30ABD1VF — Split System Air Conditioner diagram (page 2)
Fig. 3 · Split System Air Conditioner
PHYSICAL DATA MODEL SIZE18243036424860 PERFORMANCE DATA NOMINAL CAPACITY (BTUH)18,00024,00030,00036,00042,00048,00060,000 FAN DATA FAN MOTOR TYPEPSCPSCPSCPSCPSCPSCPSC HP1/61/61/51/31/31/31/3 DIAMETER18"18"18"22"22"22"24" BLADE3333333 RPM1,0501,0501,0501,0501,0501,050950 CFM1,8001,8001,8003,4003,4003,4004,000 OUTDOOR COIL TYPEEnhanced Aluminum Plate Fin / Rifled Copper Tube COIL FACE AREA (ft2)9.59.512.218.218.218.222.2 O.D.7mm7mm7mm7mm7mm7mm7mm FPI / ROWS18-218-218-218-118-218-218-3 ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V) MINIMUM CIRCUIT AMPACITY - MCA (amps) 19.111.514.318.720.323.130.1 MAXIMUM OVERCURRENT PROTECTIVE DEVICE-MOCP(amps) 215152030354050 COMPRESSOR RLA (Rated Load Amps)6.58.410.313.514.81722.1 COMPRESSOR LRA (Locked Rotor Amps)483961787886137 FAN MOTOR FLA (Full Load Amps)1.01.01.41.81.81.81.9 REFRIGERANT CONNECTIONS LIQUID LINE CONNECTION SIZE (In. OD)3/83/83/83/83/83/81/2 SUCTION LINE CONNECTION SIZE (In. OD)3/43/47/87/87/87/81 1/8 RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD)3/83/83/83/83/83/81/2 RECOMMENDED LINE SET SUCTION DIAMETER (In. OD)3/43/47/87/87/87/81 1/8 FACTORY CHARGE R-22 - OZ.721069187128150204
1. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
2. Time delay fuses may be used in place of HACR circuit breaker.
Fedders C30ABD1VF — Split System Air Conditioner diagram (page 2)
Fig. 4 · Split System Air Conditioner
Page 3 of the Fedders C30ABD1VF user manual — Split System Air Conditioner
Page 3 · click to enlarge
Page 3
Fedders C30ABD1VF — Split System Air Conditioner diagram (page 3)
Fig. 5 · Split System Air Conditioner
Fedders C30ABD1VF — Split System Air Conditioner diagram (page 3)
Fig. 6 · Split System Air Conditioner
ARI CERTIFIED COMBINATION PERFORMANCE RATINGS UNIT SIZEOutdoor UnitIndoor UnitFactory Supplied EnhancementCooling Capacity (BTUH)SEER1EER TotalSensible 18C18ABD1VFAC1A024ATXV17,50012,7501311.3 AFPB24A1TXV/TDR17,50012,7501311.3 AC1A036 + FV80A070-4TXV/TDR18,00013,5001412.0 AC1A024ATXV21,60015,7501311.3 24C24ABD1VFAFPB24A1TXV/TDR21,60015,7501311.3 AC1A042A + FV80A070-4TXV/TDR21,60017,0001412.2 AC1A042A + FV80A085-4TXV/TDR21,60017,0001412.2 30C30ABD1VFAC1A030ATXV26,60019,5001311.4 AC1A036ATXV26,60019,5001311.4 AFPB36A1TXV/TDR26,60019,5001311.4 AC1A060A + FV80A085-4TXV/TDR28,00021,0001412.0 AC1A060A + FV80A115-5TXV/TDR28,00021,0001412.0 36C36ACD1VFAC1A036ATXV34,00024,7501311.4 AFPB36A1TXV/TDR34,00024,7501311.4 AC1A060A + FV80A085-4TXV/TDR35,00025,5001411.8 AC1A060A + FV80A115-4TXV/TDR35,00025,5001411.8 42C42ACD1VFAC1A042ATXV40,00029,2501311.5 AFPC48A1TXV/TDR40,00029,2501311.5 AC1A060A + FV80A115-5TXV/TDR41,50031,0001412.0 48C48ACD1VFAC1A060ATXV44,00032,2501311.5 AFPC48A1TXV/TDR44,00032,2501311.5 60C60ACD1VFAC1A060ATXV53,00038,7501311.5 AFPC60A1TXV/TDR53,00038,7501311.5
1. TDR required to obtain SEER rating

contain the TDR as standard equipment. b. TDR kit available as accessory. Part Number TDR001A. c. Tested outdoor and indoor combinations have been tested in accordance with

DOE test procedures for central air conditioners. d. Above ratings based on 80ºF (27ºC) DB and 67ºF (19ºC) WB indoor entering

air temperature and 95ºF (35ºC) DB air entering outdoor unit.

EER - Energy Efficiency Ratio SEER - Seasonal Energy Efficiency Ratio TDR - Time-Delay Relay TXV - Thermostatic Expansion Valve

Fedders C30ABD1VF — Split System Air Conditioner diagram (page 3)
Fig. 7 · Split System Air Conditioner
Page 4 of the Fedders C30ABD1VF user manual — Split System Air Conditioner
Page 4 · click to enlarge
Page 4
Fedders C30ABD1VF — Split System Air Conditioner diagram (page 4)
Fig. 8 · Split System Air Conditioner
LINE SET LENGTH AND SIZE BTUHSUCTION LINE SIZESLIQUID LINE SIZES 15 ft.25 ft.50 ft.75 ft.15 ft.25 ft.50 ft.75 ft. 183/4"3/4"3/4"3/4"3/8"3/8"3/8"3/8" 243/4"3/4"3/4"3/4"3/8"3/8"3/8"3/8" 307/8"7/8"7/8"7/8"3/8"3/8"3/8"3/8" 367/8"7/8"7/8"7/8"3/8"3/8"3/8"3/8" 427/8"7/8"7/8"1 1/8"3/8"3/8"3/8"3/8" 487/8"7/8"7/8"1 1/8"3/8"3/8"3/8"3/8" 601 1/8"1/2"1/2"1/2"1/2" Recommended liquid and suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.) Note: See unit installation instructions for proper installation.
EXTENDED COOLING CAPACITIES OUTDOOR UNIT MODELINDOOR UNITRATINGS AT STANDARD CONDITIONSCONDENSER ENTERING AIR TEMPERATURE DEGREES (F) BTUHSEER*CFM80859095100105110115 C18ABD1VFAC1A024A17,50013650TOTAL19,10018,55018,02517,50016,80016,15015,55014,850 SENSIBLE13,90013,55013,15012,75012,25011,80011,30010,850 AC1A036A + FV80A070-418,00014640TOTAL19,70019,10018,60018,00017,40016,90016,30015,800 SENSIBLE14,30014,00013,80013,50013,20012,90012,50012,100 C24ABD1VFAC1A024A21,60013810TOTAL23,70022,90022,15021,60020,70019,95019,15018,400 SENSIBLE17,30016,75016,20015,75015,10014,55014,00013,500 AC1A042A + FV80A070-4 / AC1A042A + FV80A085-421,60014810TOTAL24,00023,20022,40021,60020,60019,80019,00018,200 SENSIBLE17,90017,60017,30017,00016,60016,30016,00015,700 C30ABD1VFAC1A030A26,600131,000TOTAL29,15028,30027,50026,60025,65024,75023,85023,000 SENSIBLE21,30020,75020,10019,50018,75018,10017,50016,800 AC1A060A + FV80A085-4 / AC1A060A + FV80A115-528,000141,000TOTAL31,00030,00029,00028,00027,00026,00025,00024,200 SENSIBLE22,20021,80021,40021,00020,60020,20019,80019,400 C36ACD1VFAC1A036A34,000131,150TOTAL37,00036,20035,15034,00032.90031,80030,70029,650 SENSIBLE27,00026,45025,65024,75024,00023,25022,50021,650 AC1A060A + FV80A085-4 / AC1A060A + FV80A115-535,000141,150TOTAL39,00037,60036,40035,00034,00033,00031,80030,600 SENSIBLE27,20026,60026,20025,50025,00024,60024,20023,600 C42ACD1VFAC1A042A40,000131,350TOTAL43,45042,30041,15040,00038,80037,65036,55035,500 SENSIBLE31,75030,85030,10029,25028,35027,50026,70025,950 TOTAL47,65046,40045,25044,00042,70041,55040,33039,200 C48ACD1VFAC1A048A44,000131,550 SENSIBLE34,75033,85033,10032,25031,20030,50029,40028,650 C60ACD1VFAC1A060A53,000131,750TOTAL56,60055,40054,15053,00051,80050,60049,50048,600 SENSIBLE41,25040,50039,55038,75037,85036,95036,15035,500

*TDR required to obtain SEER rating.

Page 5 of the Fedders C30ABD1VF user manual — Split System Air Conditioner
Page 5 · click to enlarge
Page 5
Fedders C30ABD1VF — Split System Air Conditioner diagram (page 5)
Fig. 9 · Split System Air Conditioner
SHIPPING DIMENSIONS H x W x D27 x 23 x 2327 x 23 x 2333 x 23 x 2333 x 31 x 3133 x 31 x 3133 x 31 x 312 39 1⁄ x 31 x 31 DIMENSIONS IN INCHES MINIMUM MOUNTING PAD SIZE24 x 2424 x 2424 x 2432 x 3232 x 3232 x 3232 x 32 ALL DIMENSIONSF2 1/22 1/2 E3/43/47/87/87/87/81 1/8 D3/83/83/83/83/83/81/2 C21 1/221 1/221 1/229 1/2 B26 1/226 1/232 1/239 A21 1/221 1/221 1/229 1/2 MODELSC18ABD1VFC24ABD1VFC30ABD1VFC36ACD1VFC42ACD1VFC48ACD1VFC60ACD1VF
Page 6 of the Fedders C30ABD1VF user manual — Refrigerant Variations D = R-22 Refrigerant
Page 6 · click to enlarge
Page 6

Residential & Light Commercial

AC Condensing Units Model Number Identification

C 24 A B D 1 V F * A

Product Type C = Air Conditioner CH = Heat Pump

Brand

Fitting Type V = Sweat

Nominal Capacity 18 = 18,000 BTUH [5.28 kW] 24 = 24,000 BTUH [7.03 kW] 30 = 30,000 BTUH [8.79 kW] 36 = 36,000 BTUH [10.55 kW] 42 = 42,000 BTUH [12.31 kW] 48 = 48,000 BTUH [14.07 kW] 60 = 60,000 BTUH [17.58 kW]

Electrical Designation 1 = 208 / 230 Volts, 1 Phase, 60 Hz 2 = 220 Volts, 1 Phase, 50 Hz 3 = 208 / 230 Volts, 3 Phase, 60 Hz 4 = 460 Volts, 3 Phase, 60 Hz 5 = 230 Volts, 3 Phase, 50 Hz 6 = 380 Volts, 3 Phase, 50 Hz

Series

Chassis Size B = 211⁄2" W x 211⁄2" D x H - Determined by BTU Size C = 291⁄2" W x 291⁄2" D x H - Determined by BTU Size

Refrigerant Variations D = R-22 Refrigerant

Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 (908) 604-8686 Form No. F-C13

All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc. FD-071 0507

Ask about the Fedders C30ABD1VF

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Fedders C30ABD1VF

Be the first to ask — other owners or our team will answer.

Original document

Fedders C30ABD1VF manual PDF

6 pages·172 KB·Air Conditioner·PDF