ENGLISH Important Safety Instructions 2 Installation
Window installation 3 Operation
Electronic controls 5 Cleaning the air filter 7 Service/Troubleshooting 7 Warranty 8
ESPAÑOL Instrucciones importantes de seguridad 9 Instalación
Instalación en la ventana 10 Funcionamiento
Controles electronicos 12 Limpieza del filtro del aire 14 Servicio/Localización y Solución de averías 14 Garantía 15
FRANÇAIS Directives de sécurité important 16 Installation
Installation dans une fenêtre 17 Utilisation
Commandes électronique 18 Nettoyage du filtre à air 20 Dépannage/Guide de diagnostic 20 Garantie 21
For Future Reference Write down the model and serial numbers The model and serial numbers can be found on the side of the cabinet near the control panel. Use these numbers in any cor- respondence or service calls concerning your air conditioner.
Model No., No. de Modelo, N° de modèle
Para referencia futura Escriba el número de modelo y de serie El número de modelo y de serie se encuentran en el costado del gabinete cerca del panel de control. Use estos números en toda la correspondencia o llamadas de servicio relacionadas con su acondicionador de aire.
Serial No., No. de Serie, N° de série
Pour consultation ultérieure Inscrivez les numéros de modèle et de série Noter ci-contre les numéros de modèle et de série (on les trou- ve sur le côté de la grille décorative avant, près du tableau de commande). Communiquer ces numéros lors de toute corre- spondance ou appel au service après-vente ayant trait au cli- matiseur.
Date of Purchase, Fecha de Compra, Date d’achat

ELECTRICAL REQUIREMENTS
& SAFETY PRECAUTIONS
Power Cord with Arc Detection Device The power cord supplied with this air condi- tioner is equipped with an Arc Detection Device designed to shut off power to the unit when it senses an arc fault condition. An arc fault is an unintentional electrical discharge that occurs when electrical products or wires are damaged, aged, or improperly used. An arc fault can be potentially hazardous if left undetected.

Tools Needed

p Screwdrivers p Ruler or tape measure
237⁄8” to 39” 123⁄4” min.
p Level p Pencil

275⁄8” to 39” 16” min.
1. If your air conditioner cabinet is 20” wide, it will fit window openings 23 7/8” to 39” in width. Minimum opening height is 12 3/4” from bottom of sash to sill. Removal of both filler panels permits installation in windows with a minimum opening width of 20 1/4”. This size unit requires one leveling bracket (Fig. 1). 2. If your air conditioner cabinet is 23 3/4” wide, it will fit window openings 27 5/8” to 39” in width. Minimum opening height is 16” from bottom of sash to sill. Removal of both filler panels permits installation in windows with a minimum opening width of 24”. This size unit requires two leveling brackets (Fig. 2).

Attach Filler Panels On some models...
1. Open and mark center line of window. Depending on the size of your unit, attach one leveling bracket on the center line of the window or one 8” to the right and one 8” to the left of the center line. Brackets may be attached to window sill in either direction for maximum support, depending on the depth of the window sill. 2. Mark line 1 1/4” from edge of window sill and fasten leveling bracket with 1” long wood screws at mark through larger holes in bracket (Fig. 4). 3. Screw leveling bolt in 3/8” threaded hole of leveling bracket and adjust so bolt is 1/4” below top of window sill (Fig. 5). 4. Repeat steps 2 and 3 for second leveling bracket, if required.
Bottom bar Cabinet Screws

3/8” threaded hole 1” long wood screw
Leveling bolt Leveling bracket


6 Lower window sash

5. Keeping a firm grip on air conditioner, carefully center air conditioner in window opening with the bottom bar sitting behind window sill. Be sure cabinet maintains an outward pitch. Air conditioner should slant slightly downward on the outside as shown by half a bubble off on a carpenter’s level. This outward pitch prevents water from entering the room (Fig. 6). 6. Close window until it touches behind air conditioner top bar. Slide filler panels outward until they touch window sash tracks. (Do not release grip on air conditioner until lower window sash is in final position) (Fig. 7). 7. Secure top of filler panels by driving 5/8” long wood screws through top mounting holes into window sash (Fig. 7). 8. Secure bottom of filler panels by driving 5/8” long screws into window sill through filler panel tabs (Fig. 7). 9. Cut plastic foam seal to width of window and install between upper and lower window sash (Fig. 7). 10. Use sealant to fill any minor openings. Installation in Minimum Width Window
Window sill Bottom bar
1. Remove both filler panels from air conditioner cabinet (Fig. 3). 2. Refer to steps 1 through 7 of preceding instructions (Pgs. 4 & 5). 3. Close window until it touches behind air conditioner top bar (Fig. 6). 4. Fasten lower window sash to window frame (use finishing nails, wood screws, or “L” brackets) (Fig. 7). 5. If filler is required on sides of air conditioner, cut plastic foam seal to size and fill both sides. 6. Cut plastic foam seal to width of window and install between upper and lower window sash (Fig. 7). 7. Use sealant to fill any minor openings.

Consult your authorized dealer or importer for alternative installation instructions.
Do not drill a hole in bottom pan. Unit is designed to operate with approximately 1/2” of water in bottom pan.

Power Control
B
The Power Control turns the unit on and off. Set Temperature/Timer Display
Shows the set temperature when the unit is in operation and hours when the timer is being set. THE TEMPERATURE DISPLAY ONLY SHOWS THE SET TEMPERATURE, NOT THE ACTUAL ROOM TEMPERATURE. Temperature/Timer Hour Controls
These buttons are used to raise or lower the set temperature in increments of 1° from 66°F to 88°F. By depressing both buttons at once, the display will toggle between Celsius and Fahrenheit. When the timer is being set, these buttons are used to change the hour setting in increments of 1 from 00 to 24. Check Filter Light/Reset (some models)
After 250 hours of usage the Check Filter light will turn on. At this time, the filter needs to be removed and cleaned (see page 8). After the filter is cleaned and repositioned, depress the Reset button. This will restart the counter and turn the light off. Mode Control
A
A green light will indicate which mode is currently being utilized.
Cool Mode – The unit will circulate and cool the air. Heat Mode (Heat Models Only)– The unit will circulate and heat the air. Heater Safety Feature- When heater is powered off, low fan will automatically stay on and run for 60 seconds to ensure the removal of residual heat, meanwhile, the Low Fan LED blinks until the low fan stops. Fan Mode – The unit will only circulate the air. Energy Saver Mode – (The energy saver mode is designed to operate with Cool mode only) The fan will switch from the set fan speed to LO whenever the compressor turns off in response to the thermostat. When the compressor cycles back on, the unit will return to the original fan setting. Fan Speed Control
A.
B.
D.
E.
F.
Built-in three minute timing delay.
High, Medium*, Low and Auto The settings are adjusted with the Fan Speed Control, each time the button is depressed it changes the setting. A green light will indicate which setting is currently being used.
If this electronic unit will not respond to touch pad or remote control commands, it is necessary to unplug the unit from the electrical outlet for five seconds and then plug the unit back in.
Auto restart feature: In the event of a power failure, this feature allows the unit to resume operation once power has been restored, retaining the most recent settings. Upon restoration of power, the timer mode may need to be reset if being utilized.
Heat/Cool models or units with electric heat are designed to be used only as a supplemental heat source. They should be used in addition to regular heating systems and never as the primary source of heat.

ELECTRONIC CONTROLS
Timer Control The timer can be set to either turn the unit on or off.

The functions work the same as your air conditioner’s touch controls. Air Conditioner Remote Control
Remove the back cover and insert the batteries with the poles (+) and (-) in the correct position.
AAA IEC R03 1.5V
+ -


Directing Airflow Unit is engineered with adjustable louvers to direct discharge airflow. Louvers are manually adjusted by moving levers in direction of desired airflow (Fig. 8).
Proper use and care of your air conditioner will help ensure longer life of the unit. It is recommended to annually inspect and clean the coils and condensate water passages. Expense of annual inspection is the consumers’ responsibility.
Failure to keep air filter clean will result in poor air circulation.
Before cleaning or servicing this unit, it is recommended that the unit be disconnected from any electrical supply outlet.
DO NOT operate without filter. This can render the unit inoperative.

How to Obtain Warranty Service or Parts
Room Air Conditioner Warranty
(Within the 48 contiguous United States, state of Hawaii, the District of Columbia, Puerto Rico, Mexico and Canada)
Full (Five Year) Parts and Labor Warranty During the five years after the date of original purchase, Fedders will, through its authorized servicers and free of charge to the owner or any subsequent user, repair or replace any parts which are defective in material or workmanship due to normal use. Ready access to the air conditioner is the responsibility of the owner.
First make the recommended checks in the Troubleshooting guide. Then, if you still need assistance:
Exceptions
The above warranty does not cover failure to function caused by damage to the unit while in your possession (other than damage caused by defect or malfunction), or by its improper installation, or by unreasonable use of the unit, including without limitation, failure to provide reasonable and necessary maintenance or to follow the written Installation and Operating Instructions. If the unit is put to commercial, business, rental, or other use or appli- cation other than for consumer use, we make no warranties, express or implied, including but not limited to, any implied warranty of merchantability or fitness for particular use or pur- pose.
or you may write:
CareCo, Service Department 415 W. Wabash Ave., P.O. Box 200 Effingham, IL 62401
For room air conditioners purchased for use outside North America, the manufacturer does not extend any warranty either expressed or implied. Consult your local dealer for any warranty terms extended by the importer in your country. Proof of Purchase Date
THE REMEDIES PROVIDED FOR IN THE ABOVE EXPRESS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES THEREFOR, NO OTHER EXPRESS WARRANTIES ARE MADE. ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FIT- NESS FOR A PARTICULAR USE OR PURPOSE, ARE LIMITED IN DURATION TO FIVE YEARS FROM THE DATE OF ORIGINAL PURCHASE. IN NO EVENT SHALL FEDDERS BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. NO WARRANTIES, EXPRESS OR IMPLIED, ARE MADE TO ANY BUYER UPON RESALE.
It is the responsibility of the consumer to establish the original purchase date for warranty purposes. We recommend that a bill of sale, cancelled check, or some other appropriate payment record be kept for that purpose.
Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of inci- dental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you spe- cific legal rights, and you may also have other rights which may vary from state to state.