S peed Dome EPTZ1000 USER MANUAL Date: Mar 2009.
1-1 T able of Content s 1. EPTZ1000OVER VIEW ...................................................... 1-3 1.1. Introducti on .....................................................................................................1-3 1.2. Specifications .
1-2 2.5.3. Corner mount ................................................................................. 2-22 2.5.4. Multi-Function Keyboa rd Contro ller ........................................... 2-22 3. EPTZ1000CAMERA SETUP MENU .
1-3 1. EPTZ1000OVERVIEW 1.1. Introduction EPTZ1000, an intelligent high-sp eed dome camera is ready to secure your property with its omni-directional and exact monitori ng. An 18X optical and 12X digit al zoom combining with a high-performance chip ma kes captured images clear and vivid.
1-4 All of the features make the intelligent high-speed dome camera works for a wide range and demanding application such as banks, airport s, stations, casinos, street s of cities, intelligent buildings, and etc.
1-5 1.2. Specifications Pickup Device 1/4'' SONY Type EXview HAD CCD Video Format NTSC or PAL Scanning System NTSC: 525 TV lines, 60 fields/sec PAL: 625 TV lines, 50 fields/sec Picture Elements 768 x 494 ( NTSC ) , 752 x 582 ( PAL ) Horizontal Resolution 480 TVL Sensitivity 0.
1-6 Preset Positions 192 positions Running to Position Speed 1 - 239 grade available,0.1º/s - 360º/s Dwell Time at Preset Position 1~239 second available Tour 16 groups Tour Point per Group 16 preset positions Fan & Heater Fan & Heater auto starts Position Accuracy ±0.
1-7 1.3. Feature 1.3.1. Hardware Overview EPTZ1000 Wall Mount Bracket Housing Inner Housing M5 Bolt (Hex) x3 M3 Bolt x3 BNC Cable Power Cable RS485 Cable Connection Bus Bulb Mechanical Part Camera Mod.
1-8 1.3.2. Base Board The base board that is on the bot tom of the housing connects to power cable, video cable, control cable, alarm cable, fan and heater (fan and heater are for EPTZ1000 only). In order to connect to cables, the board needs to be taken of f, and put back after finishing connecting to all cables.
1-9 SW1 ON 12345678 CPU ON 12345678 SW2 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 Protocol BAUD 1.4. EPTZ1000Connection Alarm 1 Alarm 4 Alarm 3 Alarm 2 GROUND RS485 Tx(+) RS485 Tx(-) 24V AC 110V AC Video Out POWER 24V AC / 3.5 A BNC 1.0Vpp ± 0.2V, 75 RS485 Control Line 4 ALARM INPUTS Adapter Ω EPTZ1000DN/ EPTZ500DN ALARM OUTPUTS N.
1-10 1.5. EPTZ1000 Quick Op eration Guide EPTZ1000and EKB500 (Keyboard) can work together by using factory default setting. Y ou just need to connect cables by following the step s: 1. Connect the RS485 cable to EPTZ1000and a Keyboard (EKB500). 2. Connect a video cable from EPTZ1000to a monitor .
2-1 1 2. EPTZ1000INSTALLATION 2.1. Packing List There are 3 boxes that are hous ing, bulb and mechanical part with a camera module, one wall mount bracket, one pow er adapter and one accessory packet in the p ackage.
2-12 - V ideo Cable A BNC cable is used for connecting a speed dome to a DVR or a monitor . An amplifier may be needed if the video cable is too long. - Control Cable Basically , EPTZ1000uses a differential pair to connect to other devices by cascading.
2-13 2.3.1. Address Setting The address code of the EPTZ1000should be set to correspond properly with a control device to control multiple dome cameras.
2-14 ON 12345678 Swit ch Address 1 ON 12345678 2 ON 12345678 3 ON 12345678 4 ON 12345678 5 ON 12345678 6 ON 12345678 7 ON 12345678 8 ON 12345678 9 ON 12345678 10 ON 12345678 11 ON 12345678 12 ON 12345.
2-15 ON 12345678 Switch Address 129 ON 12345678 130 ON 12345678 131 ON 12345678 132 ON 12345678 133 ON 12345678 134 ON 12345678 135 ON 12345678 136 ON 12345678 137 ON 12345678 138 ON 12345678 139 ON 1.
2-16 2.3.2. Communication Protocol Setting The 1 st , 2 nd and 3 rd bits of the SW2 are used to set communication protocol. The factory default protocol is EVF .
2-17 2.3.4. V ideo Format Setting The 6 th bits of the SW2 on the PCB board are us ed to set the video format. The default video format depends on the factory setting.
2-18 2.4. Rack and Speed Dome Inst allation 2.4.1. Inst allation Requirement s 1. Installation should be handled by a qualifi ed service agent and should comply with all local regulations.
2-19 2. Thread the cable through the hole in t he wall mount bracket, and screw in 4 M8 nuts for mounting the bracket. 3. T ake off the housing from the p acking, and take of f the baseboard (4 bolts on it.) inside the housing. Thread the cable th rough the top of the housing.
2-20 5. Align the two screw holes on the bottom of mechanical part to the two bolts on the base of the housing, and twist the mechanical part clockwise a little bit in order to engage it with the base. Screw the two bolts on the base, and then connect and fix the connection bus to the PCB board on the mechanical part.
2-21 Notice: In order to protect the bulb from dirt and scrape, please put on the gloves before installing the bulb. 7. T urn on the power , and st art to operate the EPTZ100 0. Note: When turning on the power , the EPTZ1000 will enter self-inspection mode, and carry out a self-testing program.
2-22 2.5. Sep aratel y Sold Accessories 2.5.1. Pole mount The pole mount is used for insta lling a speed dome on the ceiling indoors or outdoors. The extension poles are available for the pole mount. 2.5.2. Pole adapter The pole adapter is used for installing a wall mount bracket to a pole indoors or outdoors.
3-23 3. EPTZ1000CAMERA SETUP MENU In this section, setup and operation gui de of EPTZ1000will be in troduced. There are 25 items of the setting menu. However , ther e is only one line on the line display , so using some combination keys to operate is necessary .
3-24 3.1.1. Camera Setup Menu Press MENU to enter camera setup menu. Press Shift + Joystick up/down to change subentri es, and right/left to change the setting. 1. CAM ID : The name assigned to the camera. 2. DZOOM : Digital zoom enable or disable.
3-25 6. S.SHUTTER : (this function is only available for EPTZ1000) OFF: Disable auto slow shutter . AUTO: Auto Slow electrical shutter . In order to enhance the view in the low lux environment, slow shutter allows more light go through the shutter . 7.
3-26 12. AUTO FLIP : Flip the camera when it tilts to the 90 ° end. ON: Enable auto flip. OFF: Disable auto flip. 13. ALM-IN1 : The status of input alarm 1. NIGHT N.O.: Dome turns to “Night mode” if exter nal contact open. Dome turns to “Day mode” if external contact closed.
3-27 OFF: Disable alarm input. 17. ALM-IN PRIO : The priority of alarms. 1234: The alarm priority is 1>2>3>4. 2341: The alarm priority is 2>3>4>1. 3412: The alarm priority is 3>4>1>2. 4123: The alarm priority is 4>1>2>3.
3-28 For T our setting: Shift joystick to right and left (< >) for changing Set Numeral (T01A~T16A), then press “ Enter ” to confirm. Shift joystick to right and lef t for selecting PRE Numeral (position) from 01~99, then press “ Enter ” to confirm.
3-29 Select this item, and then press “ Enter ” to load default setting. Press “ Clr ” + “ Menu ” whenever yo u want to quit menu setting. 25. EXIT : To e x i t . Select this item, and then pr ess “ Enter ” to quit setting. Press “ Clr ” + “ Menu ” whenever yo u want to quit menu setting.
4-30 4. EPTZ1000FUNCTION SETUP AND OPERATION 4.1. Manual Control Mode ¾ Manual control: Shift Joystick Up/Down/Lef t/Right, and turn it Clockwise/Counterclockwise to control speed dome. Use the control keys which are Zoom, Focus and IRIS function keys on the keyboard to zoom In/Out, focus N (near)/F (Far), or IRIS +/-.
4-31 to enter 360° auto pan speed (1~239). The camera will turn 360° automatically , but not tilt. 4.3. Position Setting ¾ Focus on a preset position: Press the number key , and then press Position.
4-32 Dwell time: default is 2 sec; It can be changed by EVF Keyboard Set + A.Pan setting dwell time of A pos or B pos. 99 => Auto scan (360 degree) Default speed is 32. It can be changed by EVF Keyboard ( Shift + A.Pan setting speed). For EPTZ1000, We can even set camera’ s ICR Day/Night function with RS-485 command via keyboard.
4-33 ¾ One-way tour Mode: Press T our to enter the t our mode. The system will ask you to enter the tour number you would like to run, and start s the tour after pressing Enter. T o preset a tour bef ore running it is necessary . Preset a one-way tour: Press Set + T our to preset a one-way tour .
4-34 If you set the position number to 99, t he dome will do a 360 degree auto scan or AB two point pan if limit is ON. If you set t he position number to 98, the dome will do a frame scan. ¾ Delete an alarm link: P r e s s Clr + F1 to delete a link of alarm to position/tour.
4-35 RELAY JP 6 JP4 JP 3 JP 1 JP 5 Video + Video - RS485 + RS485 - AC24 AC24 JP 5 1 ~ 9 APPENDIX A: The Alarm I/O Connection There are 4 alarm inputs and 1 alarm output ava ilable. The alarm I/O connector that is marked as JP5 is a nine-pin connector .
4-36 EverFocus Electronics Corp. P/N: MW01G0040B V er . C Y our EverFocus product is desi g ned and manufactured with high qualit y materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of -life, should be disposed of separately from your household waste.
An important point after buying a device EverFocus EPTZ1000 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought EverFocus EPTZ1000 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data EverFocus EPTZ1000 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, EverFocus EPTZ1000 you will learn all the available features of the product, as well as information on its operation. The information that you get EverFocus EPTZ1000 will certainly help you make a decision on the purchase.
If you already are a holder of EverFocus EPTZ1000, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime EverFocus EPTZ1000.
However, one of the most important roles played by the user manual is to help in solving problems with EverFocus EPTZ1000. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device EverFocus EPTZ1000 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center