EPSON
C o a x
Interface Card
C82314 8
USER’S GUIDE B E D I E N U N G S A N L E I T U N G M O D E D ’ E M P L O I GUÍA DEL USUARIO

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form without the prior written permission of Seiko Epson Corporation. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this book, Seiko Epson Corporation assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.
Neither Seiko Epson Corporation nor its affiliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by the purchaser or third parties as a result of: accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product, or (excluding the U.S.) failure to strictly comply with Seiko Epson Corporation’s operating and maintenance instructions.
Epson and Epson ESC/P are registered trademarks of Seiko Epson Corporation. IBM is a registered trademark of International Business Machines Corporation. HP LaserJet is a trademark, and Hewlett-Packard and PCL are registered trademarks of Hewlett-Packard Company. Centronics is a registered trademark of Centronics Data Computer Corporation. PostScript is a trademark of Adobe Systems incorporated. Command-Pass-Thru is a registered trademark of I-O Corporation. WordPerfect is a registered trademark of WordPerfect Corporation.
Microsoft is a registered trademark of Microsoft Corporation. Univers, Times, and Helvetica are registered trademarks of Linotype AG and its subsidiaries. CG Times, CG Century Schoolbook, and Microstyle are products and CG Triumvirate is a trademark of AGFA Compugraphic, a Division of Agfa Corporation. Serifa is a trademark of Fundicion Tipografica Neufville, S.A. ITC Dingbats is a U.S. registered trademark of International Typeface Corporation.
General Notice: Other product names used herein are for identification purposes only and may be trademarks of their respective companies.
Copyright © 1992 by Seiko Epson Corporation Nagano, Japan

FOR AMERICAN USERS
This equipment has bean tested and found to comply with the limits for a Class A digital device. pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not Installed and used in accordance with the instruction manual, may cause harmful interference in which case the user will be required to correct the interference at MS own expense.
This devise complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques d&passant les limits applicables aux appareils numériques de Class A prescrites dans le réglement sur le brouillage radioélectrique édicté par le Ministére des Communications du Canada.
The connection of a non-shielded equipment interface cable to this equipment will invalldate the FCC Certification of this device and may cause interference levels which exceed the limits established by the
FCC for this equipment. It is the responsibility of the user to obtain and use a shielded equipment interface cable with this device. When this equipment is attached to some printers, you should not leave cables connected to the printer’s built-In connectors. See your printer’s user’s manual for details.
Changes or modifications not expressly approved by Seiko Epson Corporation, could void the user’s authority to operate the equipment.

USER’S GUIDE
SCHNITTSTELLENDARTE COAX C82314*
BEDIENUNGSANLEITUNG
CARTE D’INTERFACE COAX C82314*
MODE D’EMPLOI
TARJETA DE INTERFACE COAX C82314*
GUIA DEL USUARIO
SCHEDA DI INTERFACCIA COAX C82314*
MANUALE PER L’UTENTE
APPENDIX C ANHANG C/APPENDICE C/APÉNDICE C/APPENDICE C


The Epson 3270 coax interface card C82314* with PC auto parallel sharing port
is an optional Epson interface card. It allows the direct connection of supported Epson ESC/P dot matrix and laser printers to a coax type-A adapter of an IBM 3174/3274/3276 Control Unit or IBM 3270 mainframe system. In addition, a Centronics compatible mini-parallel port with auto switching allows a PC or alternate host to share the printer with the 3270 host for optimum printer utilization.
The Epson interface can emulate IBM 3287, 3268, 4214-1, and 4224 (non-IPDS) dot matrix printers and IBM 3812-1 and 4028 (non-IPDS) laser printers. When the interface is installed in an Epson printer with HP LaserJet emulation, the Computer Output Reduction (COR) feature enables data processing reports to automatically be reduced and printed on letter size paper. Also, custom Font ID’s allow you to specify multiple fonts that will automatically be used in your documents.
The Epson interface supports LU3 (DSC) and LUl .(SCS) mode printing. It has a large selection of user definable setup selections (including IBM RPQ options) that can be changed and stored in non-volatile memory using commands imbedded in documents sent to the printer (downloaded from the host). A Command Pass-Thru (hex transparency) feature allows a user to access the special features of the Epson printer directly from the coax host. The interface does not support coax host-controlled color printing options, AFP, IPDS, GDDM, APL, programmed symbols.
Epson printers that have a slot for an optional interface card are supported:
DLQ-2000 LQ-570/1070 SQ-870/1 170 EPL-4000/4100 ActionPrinter 5000/5500 ActionLaserll

The control unit (CU) is communicating with the interface card
(within past 30 seconds).
The CU is not communicating with the interface card.
The program attention (PA) manual option (see Appendix A, command 35) is active and the printer received a request (from the host software) for a PA button to be pressed by the user so printing can continue.
The user pressed and released both buttons at the same time
(for less than 1 second) sending a cancel message to the host.
Red Remains on after turn on
The interface encountered problems during its self test.
(The red LED goes off after a normal self test.)

Install the coax interface card in the same way as any Epson optional interface. This procedure is explained in detail for the individual Epson printers in either an appendix or the section on Using Printer Options in the user’s manual that comes with the printer. Please follow the instructions carefully to install the coax interface card. Secure the interface with the thumb screws. Take precautions to protect the interface card from static discharge by touching a grounded surface immediately before installing.
The mini-Centronics connector on the coax interface card can be used for automatic alternate host (PC) sharing by using the parallel printer share cable
included in the box with the interface.
The interface card is supplied with default setup selections stored in its nonvolatile
memory. These default selections will suffice for most user requirements. Refer to Appendix A for a listing of the user definable setup selections and custom features.
Verify proper installation of the coax interface card by performing an interface card self-test. The self-test also prints out the current setup selections.

After installing the interface card and performing a self-test, the interface is ready to operate in most environments. The factory default settings will be satisfactory for most programs and applications. Be sure to check Command 60 on the self test print out to confirm that the interface is configured correctly for either a dot matrix or HP laser printer.
If you are using a laser printer, make sure you set your printer’s emulation mode to match that of the interface: HP emulation or dot matrix emulation. (If your laser printer supports Epson Job Language --EJL- commands, do not change the printer’s emulation mode using the EJL command or the command-pass-thru feature while this interface is installed. Also, you may not be able to change the
printer mode using the control panel.)
If your printer prints a warning message, the interface and printer emulations do not match. Use your printer’s control panel to match the interface and printer emulation settings.
TM printer mode while this interface is installed.
Never select the PostScript
If the printer is a matrix printer, you must select character set ‘Code Page 850’ in the setup of the printer. Refer to the printer’s User’s Guide to determine how to select the character set by using either dip switches or the front panel. If you have selected HP LaserJet emulation, the ‘Roman 8’ character set is automatically selected.
All configuration selections can be changed by simply embedding commands (as defined in Appendix A) in a 3270 print job or print screen (hard copy) that is sent to the printer. These are called Host Download Commands. If the embedded
command is sent correctly, the characters that create the command are not printed. If the command is printed, then the interface did not recognize the command because of a problem in the format of the command. Correct the problem and send the command again. If you wish to confirm the active setup selections for the printer, you can print a listing page by either performing a self test (pressing and holding the top button for 2 seconds) or sending the ‘98,1’
command to the interface.
Unless the ‘99,6’ command is sent to save the active setup in non-volatile (NV) memory, the configuration commands only change the active setup values and are lost when the printer is turned off. By sending a ‘98,1’ command immediately after turning on the printer, you can identify the selections that are stored in NV memory of the interface.

If a coax host Is not available and basic setup selections need to be changed, the interface has the option of a push button setup as defined in Appendix B. This option enables the basic interface features and RPQ options to be selected.
The factory default configuration selections can be restored to the NV memory of the interface by either sending a Host Download Command ‘98,0’ or by turning on the printer when the coax cable is disconnected and performing the following steps (waft for printer to be READY):
This interface features three methods for accessing the special features of Epson
printers not normally available in the IBM printers being emulated:
Command-Pass-Thru Custom User Strings SCS Mode Transparent Data
Each of these methods is described below.
DESCRIPTION
The Command-Pass-Thru (Hex Transparency) feature allows the user to access all of the built-in features of the Epson printer whether or not these features can be accessed by the IBM host software. Command-Pass-Thru provides a method of placing printer specific command sequences into the data sent to the printer from the host. The coax interface recognizes these special sequences and “Passes the Command Thru’ to the printer. This feature allows the programmer

to’ access all of the Epson features such as color printing, superscripts; and subscripts.
Command-Pass-Thru is accomplished by converting the printer command sequence into a series of two digit hexadecimal values. For example, an Escape has a decimal value of 27 and a hexadecimal value of 1B. In Command-Pass- Thru, an Escape is the character ‘1’ followed by the character ‘B’. To allow the
coax interface to recognize the sequence, it is proceeded by a ‘delimiter sequence consisting of an ampersand (&), followed by a percent (%). Several commands may be contained within the enclosing &% pairs. Once the first &% is detected, the coax interface passes hexadecimal data to the printer until it receives the next &% or a character is received that is not in the hexadecimal range of 0 to 9 or A to F -(upper case letters only).
in addition, the user has the option of selecting a different delimiter sequence
using setup command 40 (see Appendix A, command 40).
in order to highlight a passage in a document, you may wish to use an Epson printer command such as the emphasized mode. The printer command sequence for emphasized printing listed in your Epson printer’s manual is ‘ESC E’, or ‘1B 45’ in hexadecimal, to begin emphasized print and ‘ESC F’, or ‘1B 46’ in hexadecimal, to end emphasized print.
At the point in the document where emphasized printing is desired, the sequence &% 1 B 4 5 & % should appear. When you wish to cancel emphasized printing, insert the sequence & % 1 B 4 6 & %. If the document is viewed on a CRT terminal, these characters are displayed. During printing, however, these command sequences only start and stop emphasized mode and do not appear on the paper and do not take up any space.
The spaces between each individual character must be removed from the actual command, but single spaces between pairs of characters are permitted.
Command-Pass-Thru must begin with an &% or the alternate delimiter characters specified in Command 40.
Hexadecimal values must be used in the command. These values represent ASCII data which is understood by the Epson printer.

Valid characters for hex codes are 0-9 and A-F (upper case letters only).
No spaces are allowed in the command between the ‘delimiter sequence &% and the first hexadecimal value.
A single space is permitted, but not required, to separate pairs of hexadecimal letters (to aid in easier interpretation of the hex codes).
If an error in formatting the command sequence occurs, the interface will resume printing at the point in the sequence where the error occurs.
The data included in a Command-Pass-Thru string can span print buffers. This allows transmission of long strings of hexadecimal data.
During Command-Pass-Thru, the coax interface ignores control codes (NL, LF, CR and FF) but honors the EM code.
Host download Command 55 (see Appendix A, Command 55) allows a user to permanently define six custom user strings that are frequently used (for example, a special font selection). The custom user string isactivated by simply putting the delimiter (&%), a capital letter U, and the number of the desired custom user string in the text of a page, i.e. "&%U3". The custom user strings can be any combination of text or special commands for the printer, especially ones that are often used.
SCS transparent mode (SCS TRN code 35) provides a method for transparent data transmission when operating in LU1 mode. To use this method, you must be connected to a system using SNA protocol and be operating as a Logical Unit Type 1.
A SCS TRN sequence begins with a one byte binary count immediately following the TRN code. The count indicates the number of bytes, not including the count byte, of transparent data to follow. Up to 256 bytes of transparent data can be sent in each sequence.
SCS TRN data is user-defined and is not scanned for SCS control codes. However, to emulate the characteristics of the IBM 3287, non-printable characters (i.e., control characters) are converted to hyphens. Data is translated to ASCII, with undefined characters printed as hyphens. This coax interface offers a configurable option to emulate the IBM 3287 or to pass the data without translation. Refer to Appendix A, Command 35, SCS TRN TRANSLATE.

Another method of Transparent Data Transmission is the Xerox defined SCS TRN code 36. Generally accepted for use in laser printer applications, this method is the same as the Coax Interface non-translate method above. Control code sequence rules are the same for SCS code 36 as for code 35.
If the C82314* is connected to a PC with the parallel sharing cable, the PC must be turned on.
The coax interface card has a mini-Centronics parallel connector which enables
it to automatically share the printer between the 3270 host and the alternate host (usually a personal computer). The interface periodically checks the 3270 host and the PC until it finds input data to be printed. The interface continues to print using data from the current source until the input data stops and no additional data is received for the period of time specified with Commands 50 or 51.
(Factory defaults are 5 seconds for the parallel port and 10 seconds for the 3270 port.) The other source is then checked for the presence of data to be printed. The automatic checking for data from either sources is accomplished constantly when both hosts are idle. The host with the first data will have printing priority
until it has printed all of its data and remained idle for the time interval specified in Commands 50 or 51.
The Epson printer may have large print buffers, so an actual physical break in
printing may not be seen between print jobs, yet the interface pauses for the specified time period without passing data to the printer before changing to the other port. While the 3270 host is active, the parallel port accepts the first parallel byte and then goes busy. This allows the interface to know that parallel data is waiting. Conversely, while the parallel port is printing, the 3270 coax port will receive data and then send a busy signal to the host until the printer is available (the time-out period on the parallel port has expired with no additional data having been received). PC printing longer than 20 minutes may cause the 3270 host to drop communication with the printer.
Prior to printing a coax host document, if the previous document comes from the PC sharing port, the interface card sends the coax port initialization string to the printer and restores the printer’s format that was fast specified by the coax host when switching to coax printing (see Appendix A, Command 57). Also, before printing an initial document from the PC Share port, the interface sends the user defined shared port initialization string (see Appendix A Command 56). The alternate (PC) host must send the printer all of the necessary formatting
instructions and commands for correct printing.

The C82314* coax interface provides a Centronics parallel data input port to allow automatic sharing of the Epson printer between the 3270 host and an alternate host. The parallel interface was designed to be compatible with popular printer interfaces found on personal computers. The following is a description of the parallel interface signals:
1 19 STROBE 1 IN Strobe pulse to read data in. Pulse width must be more than .5 µsec. at the interface
2 20 DATA1 2 IN These signals 3 21 DATA2 3 IN represent infor- 4 22 DATA3 4 IN mation in bits 1 to 5. 23 DATA4 5 IN 8 of parallel data 6 24 DATA5 6 IN respectively. Each 7 25 DATA6 7 IN signal is HIGH 8 26 DATA7 8 IN when data is logical 9 27 DATA8 9 IN 1 and LOW when it is logical 0.
10 28 ACKNLG 10 OUT A LOW pulse with a minimum width of 4 µsec. A low indi-
cates that data has been received and that the printer is ready to accept more data.

Signal Return Signal Parallel Direction Description Pin Pin Cable
11 29 BUSY 11 OUT A HIGH signal indi- cates that the prin- ter cannot receive data. The signal goes HIGH in these cases. -Data entry, for
each character -When off line or in error slate -When serving the IBM host and a byte of parallel data is received.
12 30 PE 12 OUT HIGH when the printer is out of paper.
13 SLCT 13 OUT Pulled up to +5V through a 3.3K ohm resistance.
14 AUTO 14 IN THIS SIGNAL IS FEED NOT SUPPORTED BY THE C82314* INTERFACE. (De-
+ lined by many printers to add a LF to each CR. The IBM 3270 protocol does not allow sup- port of this signal.


Pin

IN 31 INIT 16 Defined to reset and dear the printer when LOW; THE RESET AND CLEAR ARE NOT SUPPORTED BY THE C62314*, As the IBM host cannot be interrupt- ed by this signal. An ACKNLG is generated for hand- shaking.
This signal goes LOW when the pri- nter is in an error state such as out of paper.
34 NC Not used
35 HIGH Pulled up to +5V through a 3.3K ohm resistance
The column heading ‘DIRECTION’ refers to the direction of signal flow as viewed from the C82314* interface.
‘RETURN’ denotes the twisted-pair return, to be connected at signal ground level. For the interlace wiring, be sure to use twisted-pair cable for each signal and to complete the connection on the return side. The cable should be shielded and connected to the chassis of the host computer and printer.
All interface conditions as based on TTL levels. Both the rise and the fall times of each signal must be less than 0.2 microseconds.

Data transfer is carried out by observing the ACKNLG or BUSY signals. Data transfer to the printer occurs only after receipt of the ACKNLG signal or when the BUSY signal is LOW.
DATA IN / \ - \ /
.5usec .5usec .5usec
m i n . m i n . m i n .
BUSY -I
Approx. Approx. 7usec min 5usec.
Data must be present a minimum of 0.5 microseconds before and after a mini- mum 0.5 microsecond STROBE pulse. BUSY goes high before the end of the STROBE signal and remains high until the end of an ACKNLG pulse of minimum 4 microseconds.
Most Epson laser printers have an option to emulate the Hewlett Packard LaserJet printer. Check your user’s guide to determine if your printer has this option, which can be selected from the front panel of the printer. Be sure to save the HP option selection into the printer's default settings so the HP option is always loaded at power-on. The HP option provides increased capability including easy font selection and portrait and landscape printing.

When Command 60 (see Appendix A, command 60) of the interface is used to select HP LaserJet emulation, font changes can be accomplished by simply including the font identifier ID code in the text of the document being printed.
In the Appendix C at the back of the manual is a summary listing of the font identifier codes for the printer’s resident fonts and the Epson font cartridges. The code consists of the delimiter characters (&% or alternate delimiters)’ plus the letter "P" or "L" depending on whether the user wants portrait or landscape printing, and the font ID number.
If a non-Epson supplied HP compatible font cartridge is used, the font ID number assigned to the font in the Epson cartridges works with the HP compatible cartridges. Additional font ID numbers are assigned to other fonts available In many of the HP compatible cartridges and these are listed in an Appendix C at the back of the manual. If the font you want to use is not listed with a font ID number, it is simple to assign the font command to a custom user string and access the font by using the user string command.
Example: Code &%L086 identifies a landscape Prestige 12 CPI font in the Epson 5412 font cartridge. if the font cartridge is not installed, then the printer automatically selects an alternate landscape font and uses
it to print the document.
Multiple font changes can be made in a document as long as all fonts are specified in the same orientation. A change in orientation (portrait or landscape) automatically ejects the page. A blank page at the first of a document is often caused by a change in orientation. A font ID must be absolutely the first data on the page, i.e. at the first position on the very first line of the page when it specifies a change in orientation from the previously printed page, or a blank page will be ejected.

HP EMULATION
The landscape printing capability of the HP LaserJet emulation enables the
interface to automatically print traditional data processing reports requiring 66 lines by 132 columns or 198 columns of data on 8.5 x 11.0 inch paper.
When Command 60 selects HP LaserJet protocol and APO is active (Command 61) and COR is selected for the paper source specified (Commands 62-64), the following format changes are automatically made to data processing reports:
The Page is printed in landscape orientation.
Vertical line height is 70% of that specified.
A 0.5 inch blank area is provided on the top and left edge of the paper.
The selected font is changed, as follows:
10 pitch to 13.3 pitch 12 pitch to 15 pitch 15 pitch to 19 pitch
A combination of control codes in the printer data stream and the settings in the
configuration are used to determine page orientation when processing DSC, DSE, or LUl (SCS) data streams.
Some data processing applications will not allow the user to insert the data stream commands required to achieve orientation and format selection, Where the insertion of the required data stream commands is not possible, the user can select the orientation and format desired by using the interface’s default configuration settings. Use of the Write Control Character (WCC) in the DSC/DSE data streams for orientation and format selection is not recommended.
Using the HP LaserJet emulation, the COR feature enables 132 column X 66 line and 198 column X 66 line data processing reports to be printed on 8 1/2" X 11" paper in landscape orientation. This enables a tremendous amount of data to be stored in ordinary file cabinet drawers and a staple on the edge of the pages will secure the sequence of the pages.

HP EMULATION
When Automatic Print Orientation (APO) is specified active (see Appendix A, command 61), the coax interface notes the page format parameters of the print image and calculates the required print dimensions in inches. The page calculations are based on the following equations:
Requested Characters per line (MPP) Print Width = - (in inches) Characters per inch (CPI)
Requested Lines per Page (MPL) Print Length = - (in inches) Lines per Inch (LPI)
The printer calculates a 13.2 x 11 .0 inch page size if:
Characters per line = 132 Font = 10 pitch (CPI) Lines per page = 66 Lines per inch = 6
Because the calculated paper size is larger than 8.5 x 11.0 inches, the Paper Tray Orientation selection (see Appendix A, Commands 62-64) determines the orientation of the printing. Reference the following Page Orientation Logic Illustration.
In LU3 (DSC/DSE) mode, the values of the parameters used in the calculations are those specified by the interface’s active configuration selections. In LUI (SCS) mode, the values used are those specified in the data stream by the SCS controls. If a value has not been set in the SCS data stream, the interface’s active configuration is used.
Understand that the interface does not supply automatic orientation based on the amount of incoming data from the host for each line or page. The values must be provided in the data stream or by use of the printer’s configuration selections.
The Automatic Print Orientation (APO) feature also utilizes the requested print width and print length as specified above to determine the print orientation when the print dimensions are less than the 8.5 x 11 inch paper size, When the width
is greater than the length and APO is active, the document prints in landscape

regardless of whether the user specified a portrait font ID. You should be aware of the significance of the specified form size (as defined by the MPP and MPL) and select these values in accordance with your desired orientation when APO is active.
The page orientation logic is as follows depending on whether APO in Command 61 is active and the Paper Tray Orientation selections made in Commands 62 to 64. The requested print length and width is important when APO is active as illustrated below:
START Page Orientation Logic
APO Active - NO
Print According To Paper Tray Orientation Selection
( Command 62-64 )
Less than — NO 8.5 x 11.0 inches
Computer Portrait Landscape User output Mode Mode Defined Reduction Mode Mode
Length Less Than - NO Requested
P r i n t i n YES Portrait

This appendix defines the configuration commands which may be used to select setup values for the printer interface. These commands may be sent to the printer as part of a normal 3270 coax print job or hard copy print screen. The interface will identify the commands and obey their instructions without printing the text of the command. If the text of a command prints, check that the format of the command is correct.
The format for all configuration commands is:
&%Z‘Command Number, ‘Value and/or data’
The ‘&%’ characters are defined as the default ‘delimiter characters and the
upper case ‘Z’ is the default command ID character. It is possible to specify user selectable alternate values for the ‘delimiter characters (reference Command 40). The capital letter Z (or other command character, reference Command 41) precedes all command numbers. Chaining multiple commands together is permitted by using a slash (/) or backslash (/) to separate the commands with no spaces allowed. Each command string must be preceded by an &% and
terminated by at least one space or a control character (i.e. LF, NL, CR, or FF). Commands are utilized by the interface and sent to the printer immediately upon receipt from the host. Commands chained together with slashes and located on the first line and first position take effect immediately on the page where they are located. Otherwise they take effect on the next page.
All commands have immediate effect unless noted otherwise.
For a command to be permanently stored in non-volatile memory, the Command ‘/Z99,0’ must be used.
An error causes the interface to exit download mode and print from the
point of error.
The RPQs are only active in LU3, non-SCS mode.

Table of Contents COMMAND DESCRIPTION PAGE
01 02 03 04 05 06 07 08
Buffer Size A-2 Lines Per Inch A-2 Characters Per Inch A-3
A-3 A-3 Maximum Print Position A-4 Print Case A-4 LU1 Language A-5 Font Select (Matrix Printer) A-6
Lines Spacing Form Length
PaperPath A-6 Form Feed Before Local Screen Copy A-7 Form Feed After Local Screen Copy A-8 LU3 Print Image (Non-SCS Mode) A-8 CR at MPP + 1 A-9 NL at MPP + 1 A-9 Valid FF Followed by Data A-10 Valid FF at End of Job A-10 FF Valid Location A-11
11 12 13 14 15 16 17 18 19
20 25 26 27 31
Automatic Function at End of Job A-11 Form Feed Usage A-12 Suppress Empty Forms A-12 Form Feed After Time Elapse A-12 Truncate/Wrap Select A-13 Paper Size A-13 Intervention Required (IR) Timeout A-14 Program Attention (PA) Response A-14 Suppress Host Control Codes A-15 Vertical Channel Select (VCS) A-15 True LPI Spacing A-16
32 34 35 36 37 38
40 41 42 45
Alternate Delimiter Chars (hex) A-16 Command Id Character (hex) A-17 Start/Stop Buffer Hex Dump A-17 SCS TRN Translate A-18

Paqe 2 of the Table of Contents COMMAND DESCRlPTION PAGE
50 51 55 56 57
Parallel Port Timeout A-18 Coax Port Timeout A-19 Custom User Strings A-20 Shared Port Initialization String A-21 Coax Port Initialization String A-21
60 61 62 63 64 65 70 71 98 99
ASCII Printer Protocol A-22 Automatic Print Orientation A-23 Primary Tray Options A-23 Alternate Tray A-24 Manual Feed Options A-24 Character Set Selection A-25 Overwrite EBCDIC Translate Table A-25 Overwrite DSC Translate Table A-26 Restore Configuration A-26 Store Configuration in NV Memory A-27

Selects logical default buffer size
1 960 characters *2 1920 characters 3 2560 characters 4 3440 characters 5 3564 characters
buffer size selection in the non-volatile memory of the interface. The logical buffer size is only reported to the host the next time the unit is powered up.
The physical buffer size is permanently set at 4K.
EXAMPLE: &%Z1,3 Sets logical buffer size to 2560 characters.
Selects default LPI.
3 3 LPI 4 4 LPI *6 6 LPI 8 8 LPI
The IBM host can control the LPI unless Command 36 is used to select override of host LPI commands.
VALUE DESCRlPTlON

0 No default sent to printer *10 10 CPI 12 12 CPI 15 15 CPI 16 16.7 CPI
Selects default Line Spacing
VALUE DESCRIPTION *1 Single Space 2 Double Space
Selects default Form Length (MPL, Maximum Print Lines)
Set Form Length in number of lines
This default emulates the front panel selection on an IBM printer.
Selects default CPI · 000 to 255 · *066 (Factory Default)

Selects current and default Maximum Print Position, the maximum number Of characters which can be printed on each line.
000 Infinite Line Length
Set MPP in number of characters
* 132 (Factory Default)
This default emulates the front panel selection on an IBM printer,
MPP and the current position will not be changed by changes in CPI.
The infinite line length will place no limits on the number of characters that can be sent to the printer on a single line.
Selects default Print Case
0 Mono case *1 Dual case
Dual case = Upper and lower case characters
This default only affects LU3 printing
001 to 255

Selects default LU1 Language.
* 01 03 04 05 06 07 08 09 10 11 12 (same as 11) 13 14 15 16 17 (same as 16) 19 20 21 22 23 (same as 07) 24 (same as 09) 25 (same as 01) 26 (same as 08) 27 (same as 10) 28 29 (same as 06) 30 (same as 11) 31 (same as 14) 32 (same as 14)
English (U.S.) EBCDIC Austrian/German Belgian Brazilian Canadian (French) Danish/Norwegian Danish/Norwegian (alt.) Finnish/Swedish Finnish/Swedish (alt.) French French (alt.) Austrian/German (alt.)
International Set 5 Italian Japanese (English) French (alt.) S p a n i s h Spanish (alt.) Spanish Speaking English (U.K.) Norwegian Swedish EBCDIC (alt.) Norwegian (alt.) Swedish (at.) Portuguese Canadian (Bilingual) French AZERTY (105 character) Swiss German Swiss French
language selection in the non-volatile memory of the interface.
The number of the command value should agree with the language
number used in IBM CU configuration sequence number 121.

Selects Epson default font when dot matrix printer protocol is selected in Command 60. This command is not functional when laser printer protocol is selected.
* 1 2 3 4 5 6 7 8 9 10 11
Draft Print Quality Roman, NLQ Sans Serif, NLQ Courier, NLQ (Font Cartridge Required) Prestige, NLQ (Font Cartridge Required) Script, NLQ (Font Cartridge Required) OCR-B, NLQ (Font Cartridge Required) OCR-A, NLQ (Font Cartridge Required) Orator, NLQ (Font Cartridge Required) Orator-S, NLQ (Font Cartridge Required) Script C, NLQ (Font Cartridge Required)
Selects default paper path for the Page Presentation Media (PPM) command
DESCRIPTION
Ignore the host PPM Command; paper tray selection determined by use of the printer’s front panel.
Tractor Feed or only one paper source used (Ignore the Host
*2 Cut-Sheet Feeding from primary bin is default
3 Cut-Sheet Feeding from alternate bin is default
4 Envelope Feeder default
5 Manual Sheet Feed default
6 Manual Envelope Feed default

Presentation Media (PPM) Host command in SCS mode. If the PPM command is received from the host, the interface always sends the SCS mode paper source command to the printer unless values 0 or 1 are selected. If the printer does not have a secondary paper bin or anenvelope feeder, it ignores the command, but it will be used for Commands 62-64 logic.
If manual sheet feed is specified in the SCS PPM command and no paper is installed in the manual feed slot, the printer will wait for the operator to insert perhaps letter head or a special form before printing continues.
If this command is placed as the first printable data on the page, (line 1, position 1) the specified paper path will take effect immediately. If the command is placed at any other position on the page, the change will have effect on the next page.
Specifies whether a Form Feed is performed before-doing local screen hard copy.
* 0 No Form Feed before local screen hard copy
1 Form Feed performed before local screen hard copy
host-initiated local copy printing.
Functions only in non-SCS operations

Specifies whether a Form Feed is performed after a local screen hard copy.
*0 No Form Feed after local screen hard copy
1 Form Feed performed after local screen hard copy
IBM 3268 RPQ SC9508 IBM 3287 RPQ MC3750 IBM 4214 OPT 20=3
This command only affects the local screen copy, not the host-initiated
local copy printing.
Functions only in non-SCS operations
Selects Null Line Suppression or True Screen Image in LU3 printing mode
Null line suppression in Local Copy and non-SCS print
Null line suppression in non-SCS print and true screen image in Local Copy
2 True screen image in non-SCS print and null line suppression in Local Copy
3 True screen image in non-SCS print and true screen image in
IBM 3268 RPQ SC9505 IBM 3287 RPQ SC3741 IBM 4214 OPT 18=2
Available only in non-SCS operation
* 0 · Local copy

Command 14, Values 0 and 1 are only functional from CUT terminals.
Sets the printer in accordance with the RPQ installed in the control unit.
* 0 First print position (PP) of next line
1 First PP of current line
IBM 3268 RPQ SC9501 IBM 3287 RPQ S30219 IBM 4214 OPT 15=1
Available only in non-SCS operation
EXAMPLE: &%Z15,1 Prints first PP of current line as the next PP when a CR is received at MPP + 1.
Sets the printer in accordance with the RPQ installed in the control unit
* 0 First PP of current line + 2 lines
1 First PP of next line
IBM 3268 RPQ SC9502 IBM 3287 RPQ S30219 IBM 4214 OPT 15=1
Available only in non-SCS operation.
EXAMPLE: &%Z16,1 Performs first PP of next line as the next PP when an NL is received at MPP+ 1.

Sets the printer in accordance with the RPQ installed in the control unit
* 0 Second print position of first line on next form
1 First print position (PP) of first line on next form
IBM 3268 RPQ SC9503 IBM 3287 RPQ N/A IBM 4214 OPT 16=2
Available only in non-SCS operation
EXAMPLE: &%Z17,1 Performs first PP of first line on next form as the next PP when a valid FF (positioned anywhere but the end of an IBM print buffer) is received.
Sets the printer in accordance with the RPQ installed in the control unit
0 First PP of second line on next form
*1 First PP of first line on next form
IBM 3268 RPQ SC9504 IBM 3287 RPQ SC3749 IBM 4214 OPT 17=2
Available only in non-SCS operation
EXAMPLE: &%Z18,1 Performs first PP of first line on next form as the next PP when a valid FF is received at the end of an IBM print buffer.

Sets the printer in accordance with the RPQ installed in the control unit
* 0 FF is valid only at the first print position or at position MPP+1.
1 FF is valid anywhere it occurs.
IBM 3268 RPQ SC9506 IBM 3287 RPQ SC3739 IBM 4214 OPT 19=1
Available only in non-SCS operation.
Sets the printer in accordance with the RPQ installed in the control unit.
* 0 NL is automatically executed after the buffer is completed (unless an FF, NL, or CR was last in the buffer).
1 FF is automatically executed after the print buffer is completed (unless an FF was last in the buffer).
IBM 3268 RPQ SC9507 IBM 3287 RPQ SC3740 IBM 4214 OPT 20=2
Available only in non-SCS operation
Do not press the form feed or line feed buttons on the front of the printer. This will cause the host and printer to lose synchronization of paper position. This command reduces the need to advance the paper.
Sets the printer to issue an FF automatically at the end of the print buffer.

Enables a Forms Feed from the host system to be converted to the required number of line feeds (beneficial when forms length is controlled by the interface).
0 Pass FF from host to the printer (Laser Printer default)
*1 Count the lines in Command 5 and send multiple line feeds to the printer in place of the host FF.
EXAMPLE: &%Z25,1 Sets the printer to count the lines specified in Command 5.
Blank printout pages caused by Form Feed commands that occur at the top of a form can be suppressed.
* 0 No, do not suppress empty forms
1 Yes, suppress empty forms
at the top of form position.
This command affects printing in both DSC and SCS modes. This
differs from the IBM 3287, which suppresses Form Feeds only in DSC mode.
Sends a Form Feed if unprinted data remains in the print buffer for the specified coax port time-out interval in Command 51.

*0 No extra FF is sent
1 Send FF after time out value
host and alternate host printer sharing. (See Command 51)
Generally, the host application generates a termination FF, and there is no need to change this command from the default.
In duplex printing, the last page will be ejected.
EXAMPLE: &%Z27,1 Sends FF after time delay selected by command 51 (default = 10 sec.) when unprinted data remains in the print buffer.
The user can select whether the interface truncates or wraps the text if the
maximum print position is exceeded.
* 0 Allow text to print on next line when maximum print position
is exceeded.
1 Truncate text beyond the maximum print position
EXAMPLE: &%Z31,1 Causes text which exceeds the maximum print position to be lost.
Specifies the paper size used for printing
*0 Selects 8 1/2" X 11" letter paper
1 Selects 210mm X 297mm (8.27’ X 11.69”) A-4 paper
2 Selects 8 1/2” X 14” legal paper
EXAMPLE: &%Z32,1 The interface tells the printer to use A-4 paper.

Sets the time interval before an intervention required signal is sent to the host after a printer error occurs.
000 Never send an IR
Send IR after the VALUE times 5 seconds after printer error occurs.
* 120 Default, send IR after ten minutes.
The IBM host software can send a program attention (PA) request to the
printer, causing the printer to stop printing until a PA1 or PA2 response from the printer is sent to the host software. The interface can be set to either automatically return a PA1 response upon receiving a PA request or stop and wait (with red LED on) until the operator presses one of the two push buttons on the interface card.
*0 Printer stops and waits for operator to press a PA1 or PA2 push button before sending the PA response to the host.
1 Interface automatically responds with a PA1 if a PA request is received from the host.
colored paper, legal paper, etc. in the printer before the PA push button is pressed.
EXAMPLE: &%,Z35,1 Printer automatically responds with a PA1 response.
001 to 255

This function is used to select suppression of all or some IBM control codes
sent from the host system.
*0 Obey all IBM control codes
1 Suppress all IBM control codes
2 Suppress only LPI and CPI control codes
3 Suppress only CPI control codes
4 Suppress only LPI control codes
5 Suppress print quality specified in the PPM command.
sending transparent control codes to the printer using Command- Pass-Thru or SCS mode transparent data
If this command is set to 2, the SCS pitch (CPI) and line density (LPI) commands are suppressed (Not sent to the printer).
EXAMPLE: &%Z36,2 No LPI or CPI commands are sent to the printer. The printer prints using the user specified selections.
Specifies vertical channel select VCS) emulation.
0 3287 VCS emulation
*1 3268/4214/4224 VCS emulation

Because laser printers have a non-printable border around the edge of single- sheet pages, 6-LPI and 8-LPI spacing is compressed slightly to enable 66 lines and 88 lines to be printed on 11-inch long paper. This can occasionally cause a problem, especially with preprinted forms. Command 38 enables a user to override the normal laser printer LPI compression.
*0 Compress the vertical LPI spacing
1 Print using true 6 and 8 LPI spacing
EXAMPLE: &%Z38,1 Specifies that vertical spacing prints using true 6 and 8 LPI. For an 11" page, 63 lines at 6 LPI or 84 lines at 8 LPI are the maximum that fit on a page
Specifies two characters in addition to &% which can be used for the ‘delimiter’ characters for Command-Pass-Thru and Host Download Commands.
0000 Deletes previously selected alternate characters
XXYY XX is the ASCII HEXADECIMAL value of the first character and YY is the ASCII HEX value of the second character.
‘delimiter’ characters, % ASCII hex value is 25 and ? ASCII hex value is 3F in this example.
VALUE DESCRlPTlON

Specifies the character which can be used for the command identifier (in place of "Z" which follows the ‘Lead In’ characters.
*5A Makes Z the command character.
ZZ ZZ is the ASCII HEX value of the command ID character.
hex values), or L, P, U.
Upon receipt of a start command, the coax interface, starting with the next buffer received, sends all host data directly to the printer as hexadecimal printing until a stop command is received or the printer is powered off.
* 0 No Action Taken
1 Start Buffer Hex Dump
2 Stop Buffer Hex Dump
card and holding them for more than 2 seconds to activate Buffer Hex Dump.
This command enables the user to print only the section of the document that is in question in Buffer Hex Dump Format. But, hex printing starts with the buffer following the start command and stops with the buffer following the stop command.

Specifies how transparent data sent using SCS code 35 is handled.
* 1 Emulate IBM 3287 Printer
converted from EBCDIC to ASCII), control codes and invalid graphics to be printed as hyphens, and normal page formatting is maintained.
Value 0 causes the 8 bit binary codes to be sent directly to the printer just as they are received from the host.
SCS code 36 functions the same as code 35.
codes without translation.
Selects the time interval that the interface waits for receipt of additional data from the alternate (PC) host before automatically switching to check for data from the coax host.
Time interval in number of seconds
*5 Factory Default is 5 seconds
coax host defined format commands (i.e. LPI, CPI, MPL, MPP) prior to printing data from the coax host after having printed data from the shared parallel port.
0 Binary Transparent · 01 to 60

Because the printer is being shared between the parallel port and the 3270 host, careful attention should be paid to setting up the PC so that jobs are not automatically terminated because the printer is. busy.
This problem may be helped by setting the PC timer “off by writing "mode 1pt1:,,p" (in case of an LPT1 printer) in DOS.
Use of the DOS PRINT command or a spooling program for the PC is recommended.
If your printer supports intelligent Emulation Switching (IES), make sure your printer’s IES timeout period is less than the command 50 timeout setting.
Selects the time interval that the interface waits for receipt of additional data from the coax host before automatically switching to check for data from the alternate (PC) host.
00 The interface never checks for parallel port data (parallel shared port is disabled).
Time interval in number of seconds
*10 Factory Default is 10 seconds
If your printer supports Intelligent Emulation Switching (IES), make sure your printer’s IES timeout period is less than the command 51 timeout setting.
01 to 60

Allows a coax user to define up to six custom user strings, of up to 25 bytes each, which are stored in the memory of the interface card and sent to the printer whenever the “two-letter delimiter, letter U, and number of the string’ appears in the text of the document, i.e. &%U3.
0 Following the value number, insert a parenthesis, followed by to the ASCII hex bytes included in the user string, and then a 5 parenthesis to end.
is not included in the string.
The strings could specify a special font selection command or other
custom command to be sent directly to the printer.
This command, if placed as the first printable data at the top of the
page (position 1, line 1), will be sent to the printer prior to the data.
To change a custom user string, simply input the new custom user string values. The entire old string is automatically erased.
To delete a custom user string from the NV memory, simply put
nothing between the parentheses.
EXAMPLES: &%Z55,3(1 B01) Defines the &%U3 custom user string to send an "ESC and SOH" (1B and 01 hex) to the printer. This is the Epson Double- Width, One Line, ON command.
&%Z55,4(OF) Defines the &%U4 custom command to send "SI" (shift in, OF hex) to the printer wherever the &%U4 command appears in the text. This turns ON the Epson condensed printing.
&%Z55,5(12) Defines the &%U5 custom command to send "DC2" (Device Control 2, 12 hex) to the printer. This is the Epson condensed printing OFF command.
&%Z55,1( ) Deletes from NV memory any hex string that had been previously defined for the &%U1 custom command.

Allows the user to define an initialization string of up to 25 bytes which are stored in the memory of the interface card and sent to the printer at the beginning of any printing received from the alternate shared port.
1 Following the value number, insert a parenthesis, followed by the hex bytes included in the command string, and then a parenthesis to end.
is not included in the string.
The string could specify a special font selection command or other custom command to be sent directly to the printer prior to the data that is received from the parallel shared port.
To change the initialization string simply input the new command values. The entire old string is automatically erased.
To delete the initialization string from the NV memory, simply put
nothing between the parentheses.
EXAMPLE: &%Z56,1( ) Deletes from NV memory any hex string that had been previously defined for the parallel port initialization string.
Allows the user to define an initialization string of up to 25 bytes. This string is stored in the memory of the interface card and is sent to initialize the printer for coax port printing after printing from the shared parallel port has occurred. The interface also, after the initialization string, sends commands to restore the default or host defined page format parameters prior to coax port printing.
1 Following the value number, insert a parenthesis, followed by the hex bytes included in the command string, and then a parenthesis to end.
VALUE DESCRlPTlON

is not included in the string.
The coax port initialization string is only sent to the printer when you turn the printer on and after printing by the shared parallel port has occurred. Host SCS commands and download commands have priority over the initialization string instructions.
To change the initialization string simply input the new command values. The entire old string is automatically erased.
To delete the initialization string from the NV memory, simply put
nothing between the parentheses.
EXAMPLE: &%Z57,1( ) Deletes from NV memory any hex string that had been previously defined for the coax port initialization string
Specifies the type of ASCII printer protocol instructions that the interface will use when converting from the 3270 coax cable commands. Most Epson ESC/P printers will automatically on power up set this command to agree with the type of printer In which the interface is installed. If your printer is a laser
printer, this command is invalid.
* 1 Epson ESC/P dot matrix protocol 2 HP LaserJet PCL4 laser protocol
and Epson ESC/P requires that the Code Page 850 character set be selected by the user through front panel selections or DIP switch selections.
The HP LaserJet laser protocol supports the ability to specify cartridge fonts by simply including a font ID Command in the document.
A change in this command is not active until it is saved to NV memory using an ‘&%Z99,0’ and the unit is turned off and then on again.
When laser protocol is selected, the default for Command 25 changes to the ‘form feed’ option.
VALUE DESCRlPTlON

Laser printers automatically control page orientation if the user decides to activate auto print orientation (APO). Refer to the page orientation logic chart in the computer output reduction section of the manual.
* 0 Auto Print Orientation (APO) is ACTIVE. The page
dimensions of a document are checked to determine if the data should be printed in landscape because the width is greater than the length.
1 Auto Print Orientation (APO) is NOT ACTIVE. Print orientation is controlled by the orientation selections specified in Commands 62, 63, and 64.
A user can manipulate the page dimensions using SCS commands to control the orientation of the printing as long as the page size required is 8 1/2" X 11” or smaller.
EXAMPLE: &%Z61 ,1 APO is not active.
The SCS (LU1) PPM command, which specifies the source for the paper, assigns a printing orientation to the primary paper tray. Refer to the page orientation logic chart in the computer output reduction section of the manual. This command duplicates the IBM 3812 and 4028 printer’s feature with the additional selection of option 3 below.
*0 Computer Output Reduction (COR) Mode is active when paper is specified to be selected from the primary tray.
1 PORTRAIT orientation will occur using the active font when the primary tray is specified.
2 LANDSCAPE orientation printing occurs using the active font when the primary tray is specified.
VALUE DESCRlPTlON · VALUE DESCRlPTlON

3 User Defined mode; documents are printed using the fonts and orientation that the user specifies through use of the &% font ID commands.
EXAMPLE: &%Z62,3 Specifies that the document is printed as formatted when the primary paper tray is specified as the
paper source.
This command functions identically to Command 62 except it controls the
orientation for printing that specifies (SCS,LU1) the alternate tray for the paper source.
Values are the same as Command 62 except substitute ‘alternate tray’ for ‘primary tray’ in the descriptions.
to the primary tray, if the SCS (LUl) host specifies the alternate tray, the interface prints the document in accordance with the selection in Command 63.
The value 3 is an excellent choice when COR is not required, since the user can decide the fonts and orientation he desires by using &% font ID commands.
EXAMPLE: &%Z63,2 Specifies that landscape orientation will be used for all printing in which the SCS (LU1) PPM code specifies the alternate paper tray be used.
This command functions identically to Command 62 except it controls the
orientation for printing when the PPM Command specifies the manual feed tray far the paper source.
Values are the same as Command 62 except substitute ‘manual feed tray’ in
place of ‘primary tray’ in the descriptions.
not proceed with printing until paper is placed into the manual feed slot. This allows a user to insert special forms, letter head, or colored
paper into the manual feed slot.

EXAMPLE: &%Z64,1 Specifies all printing performed using paper from the manual feed slot be printed in portrait orientation.
Enables the user to make a special selection of the ASCII character set that is used in the conversion from EBCDIC (SCS/LU1) or DSC (LU3) to ASCII. This is the character set that the printer uses in printing. It must be selected at the printer by using the front panel or dip switches of the printer. Changing the protocol selection in Command 60 automatically changes the character set as required. However, Command 65 can override the automatic selection.
1 Roman 8 character set
* 2 Code Page 850 character set
be adjusted if the ASCII character set is changed. All previously defined substitutions are lost from NV memory when the character set selection is changed.
Refer to the character set summary tables at the end of the self test to confirm which ASCII character is printed for each of the 3270 hex codes. Both the EBCDIC and DSC tables are provided.
Custom substitutions defined by this command and stored in NV memory are written into the EBCDIC (SCS/LU1)-to-ASCII translation table.
xx The hex location in the EBCDIC table that sends the following ASCII hex sequence.
YY The ASCII hex sequence that is overwritten in the EBCDIC translation table.

selection when the same hex location is specified in the EBCDIC table.
Previously stored substitutions are cancelled if an ASCII hex sequence of 00 is specified.
Command ‘Z99,0’ must be used to store the substitutions in NV Memory for them to be effective when the printer is next turned on.
The active EBCDIC (SCS/LU1) translation table prints out at the end of the interface self-test summary.
EXAMPLE: &%Z70,7B,40/Z99,0 Overwrites the ASCII hex output for the EBCDIC 7B (a # symbol) to send a 40 ASCII hex which will print a @ symbol instead. The command is followed by a command ‘Z99,0 which stores the active setup selections in non-volatile memory.
Custom substitutions defined by this command, and stored in the NV memory,
are overwritten into the DSC (LU3) to ASCII translation table.
substitutions are applicable to the DSC (LU3) translation table. Refer to the Command 70 instructions.
The active DSC (LU3) translation table prints out at the end of the interface self-test summary.
Restores the factory default configuration selections, prints out a copy of the active configuration selections, or restores the non volatile memory (NV) selections to the active configuration status.

0 Restores the factory defaults to the NV memory of the interface.
1 Prints out the active setup selections for review by the user.
2 Restores the setup selections stored in the NV memory to active status of the interface.
selections if no host download commands have been sent to the printer since it was turned on.
Value 2 is a quick way, after having printed a document using special setup selections, to return the interface to the normal selections. Put a &%Z98,2 at the end of the special document to restore the standard setup parameters for the next coax user of the printer.
The active setup and NV memory setup selections are the same after a command ‘Z99,0 or a Command ‘Z98,2’ is sent to the printer.
EXAMPLE: &%Z98,1 Prints out the active-setup selections for review by the user.
Send this command after all desired host download configuration commands have been sent to the interface. It stores the active setup in the NV memory of the interface so that it will be in effect whenever you turn on the printer. Otherwise, active configuration commands are lost when the printer is turned
Off.
0 To complete the command format, the value 0 must be used.
Command ‘Z99,0’ will be stored in NV memory and restored to the active setup when the printer is turned on.
Only use Command ‘Z99,0’ when the host download selection needs to be permanently stored in the memory of the coax interface.
EXAMPLE: &%Z99,0 Stores the currently active setup selections in the NV memory of the interface.

Push button (Yes / No) setup provides an alternate method for a user to select the basic configuration selections for the printer emulation. Selections can also be changed by the Host Download Configuration Commands as specified in Appendix A which has more detailed information on the selections.
Push button setup is selected by performing a self test and at the end of the self test print out the last line of printing will have the question: ‘Do you want to do push button set up?’ Press the PA1 push button to answer the question"Yes". Press the PA2 push button to answer the question “No’, or simply turn off the printer to discontinue push button setup.
A detailed example of the Push Button Setup printout is as follows:
1920 = Logical Buffer Size
Do you want this changed? (Yes I No) Yes
2560= Logical Buffer Size
Do you want this changed? (Yes / No) Yes
3564= Logical Buffer Size
Do you want this changed? (Yes / No) Yes
3440 = Logical Buffer Size Do you want this changed? (Yes / No) Yes
960 = Logical Buffer Size
Do you want this changed? (Yes / No) Yes
1920= Logical Buffer . ..(Sequence repeats until a ‘No’ response is given)
A “Yes’ response causes the next selection in the option group to be substituted into the printed statement with a similar Yes / No response requested. When the ‘No’ button is pushed, the current configuration selection remains and the selection jumps to the next configuration setup option group. The selections are
B-l

grouped together with periodic opportunities to end push button setup provided at the end of each group.
Following is the summary list of the push button setup option groups that are used to select the basic configuration. The underlined segment of each statement is the portion that changes.
*Epson ESC/P dot matrix protocol active Do you want this changed? (Yes/ No) Alternate Selections:
* HP Laserjet PCL
* Epson ESC/P dot matrix
*1920= Logical Buffer Size (Reference Command 1) Do you want this changed? (Yes / No) Alternate Selections:
* 2560 *3564 * 3440 * 960 * 1920
*6 = Default LPI Do you want this changed? (Yes / No) Alternate Selections:
* 8 * 3 * 4 * 6
*10 = Default CPI Do you want this changed? (Yes/No) Alternate Selections:
* 12 * 15 * 16.7 * 10
(Reference Command 60) · (Reference Command 2) · (Reference Command 3)

*Single (6 or 8 LPI) = Default Spacing Do you want this changed? (Yes I No) Alternate Selections:
*Double (3 or 4 LPI) * Single (6 or 8 LPI)
* 66 = MPL (Reference Command 5) Do you want this changed? (Yes / No) Alternate Selections:
* 72 * 84 * 66
*132 = Default MPP (Reference Command 6) Do you want this changed? (Yes / No) Alternate Selections:
* 198 * 255 * Infinite * 80 * 132
*Dual Case = Default Print Case Do you want this changed? (Yes / No) Alternate Selections:
* Mono * Dual
*English (U.S.) = Default Language (Reference Command 8) Do you want this changed? (Yes I No) Alternate Selections: * Austrian / German * Belgian * Brazilian * Canadian / French * Danish / Norwegian * Danish / Norwegian (alt) * Finnish / Swedish * Finnish / Swedish (alt)
(Reference Command 4) · (Reference Command 7)

* French * Austrian / German (alt) * International * Italian * Japanese (English) * Spanish * Span&h (alt) * Spanish Speaking * English (U.K.) * Portuguese * English (U.S.)
Do you want to END? (Yes / No) NO response continues with following set-up selections. YES response prints: Save current settings? (Yes / No) YES response prints: Selections stored, turn off unit.
*No FF before local screen hard copy Do you want this changed? (Yes / No) Alternate Selections: * FF
*No FF after local screen hard copy Do you want this changed? (Yes / No) Alternate Selections: * FF * No FF
*LU3 and Local COPY Null line suppression Do you want this changed? (Yes I No) Alternate Selections:
* LU3 * Local copy * NO
* LU3 and Local Copy

*Next Line first PP, for CR at MPP + Do you want this changed? Alternate Selections: * Current line * Next line
1 (Yes / No)
*Current Line + 2 is next PP for NL at MPP + 1 Do you want this changed? (Yes / No) Alternate Selections:
* Current line + 2
* 2nd PP of line 1 on next form, for FF Do you want this changed? (Yes / No) Alternate Selections:
* 1st PP * 2nd PP
*Line 1 first PP of next form, for valid FF at EOB Do you want this changed? (Yes / No)
*FF valid at 1st PP or MPP + 1 Do you want this changed? (Yes / No) Alternate Selections: * FF valid anywhere
* FF valid at 1st PP or MPP + 1
* NL will be added at EOB if not present Do you want this changed? (Yes / No) Alternate Selections: * FF * NL

Do you wish to end? (Yes / No) NO response continues with following set up selections. YES response prints: Save current settings? (Yes / No) YES response prints: Selections stored, turn off unit.
*Multi LF’s used to eject forms (Reference Command 25) Do you want this changed? (Yes / No) Alternate Selections: * FF * Multi LF
*Suppress empty forms (Reference Command 26) Do you want this changed? (Yes / No) Alternate Selections: * Do not suppress empty forms. * suppress empty forms.
*Do Not FF if data in the printer after time out Do you want this changed? (Yes / No) Alternate Selections:
* Do * Do not send
*Wrap text beyond MPP (Reference Command 31) Do you want this changed? (Yes I No) Alternate Selections:
* Truncate * Wrap
(Reference Command 27)

*10 min. = IR timeout Do you want this changed? (Yes I No) Alternate Selections: * 20 min * Disabled * 5 sec * 30 sec * 60 sec * 3 min * 10 min
*Manual PA1/2 response Do you want this changed? (Yes / No) Alternate Selections:
* Auto PA1 * Manual PA1/2
*No IBM control codes suppressed (Reference Command 36) Do you want this changed? (Yes / No) Alternate Selections:
* CPI * LPI * CPI/LPI * Print quality * All * No
* 3268/4224 VCS emulation (Reference Command 37) Do you want this changed? (Yes / No) Alternate Selections:
* 3287 * 3268/4224
*Compressed LPI spacing Do you want this changed? (Yes / No) Alternate Selections:
* True * Compressed (Normal)
(Reference Command 34) · (Reference Command 35) · (Reference Command 38)

*3287 emulation of SCS command 35 (Reference Command 45) Do you want this changed? (Yes / No) Alternate Selections: * Binary transparent data * 3287
*5 Seconds for Parallel Port time out Do you want this changed? (Yes / No) Alternate Selections: * 10 * 20 * 30 * 60 * 5
*10 Seconds for Coax Port time out Go you want this changed? (Yes / No) Alternate Selections:
* 20 * 30 * 60 * 5 * 10
Do you want to END? (Yes / No) NO response continues,with following set-up selections. YES response prints: Save current settings? (Yes / No) YES response prints: Selections stored, turn off unit.
*APO active Do you want this changed? (Yes / No) Alternate Selections: l APO not l APO
(Reference Command 50) · (Reference Command 51) · (Reference Command 61)

*COR Is primary paper tray orientation Do you want this changed? (Yes / No) Alternate Selections:
* Portrait * landscape
* User Defined * COR
* COR is secondary paper tray orientation Do you want this changed? (Yes / No) Alternate Selections: * Portrait * Landscape * User Define * COR
*COR is manual paper tray orientation (Reference Command 64). Do you want this changed? (Yes / No) Alternate Selections: * Portrait * Landscape * User Define * COR
*Code Page 850 is character set Do you want this changed? (Yes / No) Alternate Selections: * Roman 8 * Code Page 850
SAVE CURRENT SETTINGS? (Yes / No) YES Response Prints: Selections stored, turn off unit.
NO Response returns to the beginning.
(Reference Command 62) · (Reference Command 63) · (Reference Command 65)