Instruction/ maintenance manual of the product RH-65C-1 Empire Comfort Systems
Go to page of 18
12822-2-0903 Page 1 WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr op- erty damage, personal injury or loss of life. — Do not stor e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Page 2 12822-2-0903 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas .............................
12822-2-0903 Page 3 • Due to high temperatures, the room heater should be located out of traffic and away from furniture and drap- eries. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
Page 4 12822-2-0903 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor.
12822-2-0903 Page 5 INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented room heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation.
Page 6 12822-2-0903 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3 cm 1.0 cm 1.3 cm 1.0 cm 10-40 1/2" 1/2" 5/8" 1/2" 1.
12822-2-0903 Page 7 CLEARANCES Clearances: When facing the front of the room heater the minimum clearances to combustible construction (material) are the following: Left side 6 inches (152mm). Right side 6 inches (152mm). Recommend 18 inches ((457mm) on left side for servicing.
Page 8 12822-2-0903 VENT SAFETY SHUT OFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system.
12822-2-0903 Page 9 1. STOP! Read the safety information above on this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”.
Page 10 12822-2-0903 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet.
12822-2-0903 Page 11 Cleaning Pilot Burner After use, cleaning of the pilot burner may be required for the proper flame. The pilot orifice can be cleaned with high pressure air or by placing under running water. Pilot orifice must be dry before replacement.
Page 12 12822-2-0903 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 23 11713 Pilot Tubing (RH-65-6) 24 RH-457 Air Shutter Bracket 25 P-267 Manifold Assembly (RH-50-6) 25 P-268 Manifold Assembly (RH-65-6) 26 P86-3.
12822-2-0903 Page 13 P AR TS VIEW RH-50 & RH-65.
Page 14 12822-2-0903 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 18 R-6126 Electrode and Wire Assembly 19 11712 Pilot Tubing (RH-50C-1) 19 11713 Pilot Tubing (RH-65C-1) 20 RH-457 Air Shutter Bracket 21 P-267 Manifold Assembly (RH-50C/CB-1) 21 P-268 Manifold Assembly (RH-65C-1) 22 P86-3.
12822-2-0903 Page 15 P AR TS VIEW RH-50C & RH-65C.
Page 16 12822-2-0903 Figure 4 Installing Optional Blower 1. Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1) 2. Align blower cushion with bottom assembly air discharge opening. Foil face side of blower cushion should be placed upward.
12822-2-0903 Page 17 Attention : Wiring harness on blower is factory assembled and installed. If wiring harness becomes disassembled use the following steps to reassemble the wiring harness. 1. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control assembly.
Page 18 12822-2-0903 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen F reeb urg A v e. Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: inf o@empirecomf ort.com WEB SITE: www .
An important point after buying a device Empire Comfort Systems RH-65C-1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Empire Comfort Systems RH-65C-1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Empire Comfort Systems RH-65C-1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Empire Comfort Systems RH-65C-1 you will learn all the available features of the product, as well as information on its operation. The information that you get Empire Comfort Systems RH-65C-1 will certainly help you make a decision on the purchase.
If you already are a holder of Empire Comfort Systems RH-65C-1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Empire Comfort Systems RH-65C-1.
However, one of the most important roles played by the user manual is to help in solving problems with Empire Comfort Systems RH-65C-1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Empire Comfort Systems RH-65C-1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center