Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manualp.1Table Of Contentsp.51 Overviewp.71.1 Specificationsp.71.2 MRLDS Modelsp.71.3 Powering The MRLDSp.72 Choosing a Mounting Locationp.82.1 Mounting The Sensorp.82.2 MRLDS Dimensionsp.93 MRLDS Analog Version (809-100x)p.93.1 Network Layoutp.93.2 MRLDS Wiringp.93.3 Refrigerant Jumper Settingsp.103.4 Controller Setup For Analog MRLDSp.103.4.1 E2 Controllers Version 2.5 and Newerp.103.4.2 Einstein/E2 Controllers Prior to Version 2.5p.103.4.3 RMCC Controllersp.114 MRLDS Modbus Version (809-101x)p.114.1 Network Layoutp.114.2 MRLDS Setupp.114.2.1 MRLDS Wiringp.114.2.2 MRLDS Network Addressingp.114.2.3 Address Settingsp.124.2.4 Refrigerant Jumper Settingsp.124.2.5 MRLDS Terminationp.124.2.6 Modbus Outputp.124.3 MRLDS Gatewayp.134.3.1 MRLDS Gateway Setup on I/O Networkp.134.3.2 Gateway Connectionsp.134.3.3 The Gateway Boardp.134.3.4 Powering the Gateway Boardp.144.3.5 Connecting the Gateway Board to the Einstein or REFLECS Networkp.144.3.6 Wire Connectionsp.144.3.7 Termination Settingsp.154.3.8 Gateway Board I/O Net Addressingp.154.3.9 Setting the Baud Rate Dip Switchesp.164.3.10 Hand-Held Terminal Settingsp.164.3.10.1 MRLDS Setupp.164.3.10.2 Select Screenp.164.3.10.3 Status Screenp.164.3.10.4 Setup/Online Screenp.174.3.10.5 Firmware Revision Screenp.174.3.11 Gateway Troubleshootingp.174.4 Controller Setup for Modbus MRLDSp.174.4.1 Mapping The MRLDS as an IRLDS Applicationp.174.4.2 Designating MRLDS as a 16AI Boardp.174.4.3 E2/Einstein Controllersp.184.4.4 RMCC Controllers Version 2.1 and Newerp.184.4.4.1 REFLECS Setup for IRLDS IIsp.184.4.5 BEC and RMCC Controllers Less Than Version 2.1p.194.4.5.1 Input Definitionsp.194.4.5.2 Sensor Setupp.194.4.5.3 Sensor Setpointsp.194.4.5.4 Alarm Setpointsp.205 Diagnosticsp.205.1 MRLDS LED Indicatorsp.205.2 E2 Alarmingp.205.2.1 IRLDS Modep.205.2.2 16AI Modep.20
Page 1 of the Emerson MRLDS user manual — 026-1307 Rev 1 11-30-07
Page 1 · click to enlarge
Page 1

026-1307 Rev 1 11-30-07

Modular Refrigerant Leak Detection

Sensor (MRLDS) Installation and

Operation Manual

Emerson MRLDS — 026-1307 Rev 1 11-30-07 diagram (page 1)
Fig. 1 · 026-1307 Rev 1 11-30-07
Emerson MRLDS — 026-1307 Rev 1 11-30-07 diagram (page 1)
Fig. 2 · 026-1307 Rev 1 11-30-07
Page 2 of the Emerson MRLDS user manual — Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manual
Page 2 · click to enlarge
Page 2
Page 2 of the Emerson MRLDS user manual — Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manual
Page 3 of the Emerson MRLDS user manual — FCC COMPLIANCE NOTICE
Page 3 · click to enlarge
Page 3

Computer Process Controls, Inc.

1640 Airport Road Suite #104 Kennesaw, GA 31044

ALL RIGHTS RESERVED

The information contained in this manual has been carefully checked and is believed to be accurate. However, Computer Process Controls, Inc. assumes no responsibility for any inaccuracies that may be contained herein. In no event will Computer Process Controls, Inc. be liable for any direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. In the interest of continued product development, Com- puter Process Controls, Inc. reserves the right to make improvements to this manual, and the products described herein, at any time without notice or obligation.

Computer Process Controls, Inc. products may be covered by one or more of the fol- lowing Computer Process Controls U.S. patents: 6360553, 6449968, 6378315, 6502409, 6779918, and Computer Process Controls Australian patent No. 775,199 No- vember 4, 2004.

FCC COMPLIANCE NOTICE

This device complies with Part 15 of the FCC Rules. Operation is subject to the fol- lowing two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Phone 770-425-2724 · Fax 770-425-9319

Page 4 of the Emerson MRLDS user manual — Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manual
Page 4 · click to enlarge
Page 4
Page 4 of the Emerson MRLDS user manual — Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manual
Page 5 of the Emerson MRLDS user manual — Table of Contents
Page 5 · Contents
Contents

Contents

Modular Refrigerant Leak Detection Sensor (MRLDS) Installation and Operation Manualp.1Table Of Contentsp.51 Overviewp.71.1 Specificationsp.71.2 MRLDS Modelsp.71.3 Powering The MRLDSp.72 Choosing a Mounting Locationp.82.1 Mounting The Sensorp.82.2 MRLDS Dimensionsp.93 MRLDS Analog Version (809-100x)p.93.1 Network Layoutp.93.2 MRLDS Wiringp.93.3 Refrigerant Jumper Settingsp.103.4 Controller Setup For Analog MRLDSp.103.4.1 E2 Controllers Version 2.5 and Newerp.103.4.2 Einstein/E2 Controllers Prior to Version 2.5p.103.4.3 RMCC Controllersp.114 MRLDS Modbus Version (809-101x)p.114.1 Network Layoutp.114.2 MRLDS Setupp.114.2.1 MRLDS Wiringp.114.2.2 MRLDS Network Addressingp.114.2.3 Address Settingsp.124.2.4 Refrigerant Jumper Settingsp.124.2.5 MRLDS Terminationp.124.2.6 Modbus Outputp.124.3 MRLDS Gatewayp.134.3.1 MRLDS Gateway Setup on I/O Networkp.134.3.2 Gateway Connectionsp.134.3.3 The Gateway Boardp.134.3.4 Powering the Gateway Boardp.144.3.5 Connecting the Gateway Board to the Einstein or REFLECS Networkp.144.3.6 Wire Connectionsp.144.3.7 Termination Settingsp.154.3.8 Gateway Board I/O Net Addressingp.154.3.9 Setting the Baud Rate Dip Switchesp.164.3.10 Hand-Held Terminal Settingsp.164.3.10.1 MRLDS Setupp.164.3.10.2 Select Screenp.164.3.10.3 Status Screenp.164.3.10.4 Setup/Online Screenp.174.3.10.5 Firmware Revision Screenp.174.3.11 Gateway Troubleshootingp.174.4 Controller Setup for Modbus MRLDSp.174.4.1 Mapping The MRLDS as an IRLDS Applicationp.174.4.2 Designating MRLDS as a 16AI Boardp.174.4.3 E2/Einstein Controllersp.184.4.4 RMCC Controllers Version 2.1 and Newerp.184.4.4.1 REFLECS Setup for IRLDS IIsp.184.4.5 BEC and RMCC Controllers Less Than Version 2.1p.194.4.5.1 Input Definitionsp.194.4.5.2 Sensor Setupp.194.4.5.3 Sensor Setpointsp.194.4.5.4 Alarm Setpointsp.205 Diagnosticsp.205.1 MRLDS LED Indicatorsp.205.2 E2 Alarmingp.205.2.1 IRLDS Modep.205.2.2 16AI Modep.20
Page 7 of the Emerson MRLDS user manual — 1.3 Powering The MRLDS
Page 7 · click to enlarge
Page 7

1 Overview

Emerson MRLDS — 1 Overview diagram (page 7)
Fig. 3 · 1 Overview

CPC specs a modular refrigerant leak detection sensor (MRLDS) that continuously monitors for low levels of refrigerants most commonly used in commercial refrigera- tion systems.

The MRLDS communicates with the E2 controller via a Gateway board connected to the RS485 I/O Network, or via the analog input on a MultiFlex board.

1.1 Specifications

Figure 1-1 - Sensor Base Opening With Screw Terminals

1.2 MRLDS Models

Power Requirements24 VAC, ±20%, 50/60 Hz, Class 2 Wiring14 AWG max, Class 2 copper wiring Power ConsumptionLess than 2.7 watts Output Options1-5V, 10 K Ohm load RS485 Modbus RTU Operating Temp.32 to 149°F (-22 to 149°F with de-icer*) 0 to 65°C (-30 to 65°C with de-icer*) Humidity0 to 99% non-condensing Size4.5” x 3.5” x 1.6” Weight.35 lbs. (160 g) Pollution Degree2 Installation CategoryII Range0 to 1000 ppm Minimum Detection25 ppm PressureOperating 10.2 to 15.7 PSIA Repeatability±10 ppm at 50 ppm Linearity±10 ppm from 25-50 ppm, ±20% of reading from 60 to 1000 ppm Warm-up Time30 minutes
Part NumberDescription 809-1000Voltage Out w/o de-icer* 809-1001Voltage Out w/ de-icer* 809-1010Modbus w/o de-icer* 809-1011Modbus w/ de-icer*

Table 1-2 - Available MRLDS Models

1.3 Powering The MRLDS

Part NumberTransformer DescriptionNumber of MRLDS Units Powered 640-003924VAC, 10VA Class 2Up to 3

Table 1-3 - MRLDS Transformer Specifications

The MRLDS unit requires a separate UL Listed/CSA Certified 24VAC Class 2 transformer power supply. One 24VAC, 10VA Class 2 transformer is sufficient for up to three (3) MRLDS units.

CPC supplies several sizes of transformers for power- ing multiple MRLDS units (three or more). Note that polarity must be maintained when connecting more than one MRLDS to a single transformer.

Table 1-1 - MRLDS Unit Specifications

*De-icer: for environments below 32°F to keep ice from forming on the surface of enclosure.

Specifications Overview • 1

Page 8 of the Emerson MRLDS user manual — 2 Choosing a Mounting Location
Page 8 · click to enlarge
Page 8

If a transformer is shared between MRLDS units, the “ACN” of each MRLDS must be wired to the same phase of the transformer.

Emerson MRLDS — 2 Choosing a Mounting Location diagram (page 8)
Fig. 4 · 2 Choosing a Mounting Location

MRLDS I MRLDS II

120VAC 24VAC

ACN

Figure 1-2 - Powering Multiple MRLDS Units

Figure 2-1 - Sensor Base And Cover

2 Choosing a Mounting Location

2.1 Mounting The Sensor

The refrigeration monitor comprises two basic parts: the base and the cover. The cover incorporates the circuit board with the sensing elements.

Proper location of the refrigerant sensor is necessary to ensure accurate measurement of representative air sam- ples.

1. Fasten the base to a junction box or other support. The base has a number of openings to allow for mounting to various junction boxes.

Mount the sensor:

2. Feed the power and signal wires through the rectangular opening in the base ( Figure 1-1 ).
  • Indoors, inside a room area where air circulates freely.
3. Connect the wires to the terminal connector located in the base, as indicated in Figure 4-2 and Figure 3-2 .
  • On a flat, interior surface.
  • Approximately 12-18 inches (30-45 cm) from the floor.
4. The Modbus MRLDS must be connected to earth ground. Connect earth ground to the MRLDS

Do not mount the sensor:

ground terminal labeled . Connect to earth ground with 14 AWG wire that is less than 6 inches.

  • On surfaces in unheated areas (less than 0°C ), unless using a model with a de-icer.
  • Near heat sources, such as appliances, direct sunlight, or concealed pipes or chimneys.
5. Align the two side tabs of the cover with the base and snap the cover onto the base.
  • On walls subject to excessive vibration.
6. Verify the cover is securely attached to the base by pulling on the top and bottom of the cover as shown in Figure 2-2 .
  • In the direct path of an exhaust fan. Excessive air movement will disperse gas before it can be detected. If mounting in the path of excessive airflow cannot be avoided, it will be necessary to turn OFF air circulation for 1/4 to 1/2 hour, 4-6 times a day.

Transformer

Page 9 of the Emerson MRLDS user manual — 3.2 MRLDS Wiring
Page 9 · click to enlarge
Page 9

3 MRLDS Analog Version (809-100x)

Emerson MRLDS — 3 MRLDS Analog Version (809-100x) diagram (page 9)
Fig. 5 · 3 MRLDS Analog Version (809-100x)

3.1 Network Layout

Emerson MRLDS — 3.1 Network Layout diagram (page 9)
Fig. 6 · 3.1 Network Layout

Figure 2-2 - Attaching and Removing Cover

2.2 MRLDS Dimensions

Emerson MRLDS — 2.2 MRLDS Dimensions diagram (page 9)
Fig. 7 · 2.2 MRLDS Dimensions

Figure 3-1 - Analog MRLDS Network Layout Example

3.2 MRLDS Wiring

For analog MRLDS units, connect to a MultiFlex board via the analog input (use Belden 8761 cable).

Emerson MRLDS — 3.2 MRLDS Wiring diagram (page 9)
Fig. 8 · 3.2 MRLDS Wiring

INPUT 13 INPUT 14 INPUT 15 INPUT 16 1 2 3 4 5 6 7 8 0V SIG 0V SIG SIG SIG 0V 0V

be shared between MRLDS and the MultiFlex board. A

Figure 2-3 - MRLDS Mounting Dimensions

If a transformer is shared between MRLDS units, the “ACN” of each MRLDS must be wired to the same phase of the transformer.

EARTH SHIELD NEAR THE MULTIFLEX BOARD. CONNECT THE SHIELD TO THE 0V INPUT ON THE MULTIFLEX BOARD.

Wire MultiFlex SIG to MRLDS OUT(V). Wire MultiFlex 0V to MRLDS Ground ( ).

Figure 3-2 - Analog MRLDS Wiring

MRLDS Dimensions MRLDS Analog Version (809-100x) • 3

Page 10 of the Emerson MRLDS user manual — 3.4.1 E2 Controllers Version 2.5 and Newer
Page 10 · click to enlarge
Page 10

3.3 Refrigerant Jumper Settings

5. Select the board/point input.
6. Press F1 Setup .
7. Select Analog Sensor.

The jumper settings for refrigerant types are located on the label inside the MRLDS sensor cover (shown in Fig- ure 1-1). Set the jumpers according to how they are indi- cated on the label.

8. On the Analog Input screen, select MRLDS Refr. as the Sensor Type . The parameters are then automatically configured for you.
9. Press the J (Back) button to save changes.

The MRLDS supports three different refrigerant types. Select the desired refrigerant type by setting one jumper to the J2 or J1 sockets (Figure 2-1) respective per the inside label.

If the device is configured and powered correctly, a value will be visible under the Value column on the Input Status screen. 3.4.2 Einstein/E2 Controllers Prior to Version 2.5

For Einstein and E2 controllers prior to version 2.5, follow the steps below, set the sensor type to Linear, and manually enter the parameters:

J2 J1

J2 J1

1. Log into the E2 controller.
2. Press the Menu button to open the Main Menu.
3. Select 7. System Configuration .
4. Select 1. Input Definitions .
5. Select the board/point input.

Figure 3-3 - Analog Jumper Layout (Inside Lower Portion of Cover) Enlarged To Show Detail

6. Press F1 Setup .
7. Manually enter the following parameters on the Input Setup screen:
Refrigerant TypeJ2|J1 R-22 R-404A R-134A
  • Sensor Type: Linear
  • Low End Point: 0.8V
  • Low Eng. Units: -50
  • Select Eng. Units: PPM
  • HighEnd Point: 5.5V
  • High Eng. Units: 1125
  • Low End Limit: -100

Table 3-1 - Refrigerant Jumper Settings

  • HighEnd Limit: 1150

3.4 Controller Setup For Analog MRLDS

(Set the alarm failure to < -10PPM.)

8. Press the J (Back) button to save changes.

If the device is configured and powered correctly, a value will be visible under the Value column on the Input Status screen.

3.4.1 E2 Controllers Version 2.5 and Newer

1. Log in to the E2 controller.
2. Press the Menu button to open the Main Menu.
3. Select 7. System Configuration .
4. Select 1. Input Definitions .

Analog Jumpers · refrigerant type jumpers

Page 11 of the Emerson MRLDS user manual — 4.1 Network Layout
Page 11 · click to enlarge
Page 11

4.2 MRLDS Setup

Emerson MRLDS — 4.2 MRLDS Setup diagram (page 11)
Fig. 9 · 4.2 MRLDS Setup

4.2.1 MRLDS Wiring

Emerson MRLDS — 4.2.1 MRLDS Wiring diagram (page 11)
Fig. 10 · 4.2.1 MRLDS Wiring

be shared between MRLDS and the Gateway board. A

If a transformer is shared between MRLDS units, the “ACN” of each MRLDS must be wired to the same phase of the transformer.

Figure 3-4 - Analog Input Screen Settings Example for E2

3.4.3 RMCC Controllers

For RMCC-type controllers, set the Gain parameter to 250 and Offset to -1000.

Figure 4-2 - Modbus MRLDS Wiring

4 MRLDS Modbus Version (809-101x)

4.2.2 MRLDS Network Addressing

Modbus network settings are set on jumpers J5, J4, and J3. Refer to Table 4-1 (also included on the inside label of the MRLDS) for network addressing with corre- sponding jumper settings.

4.1 Network Layout

If more than one MRLDS is on the network, each unit must have a unique address and be numbered according to the inside label (Table 4-1) specifications.

Emerson MRLDS — 4.1 Network Layout diagram (page 11)
Fig. 11 · 4.1 Network Layout
Emerson MRLDS — 4.1 Network Layout diagram (page 11)
Fig. 12 · 4.1 Network Layout

(Up to 12 MRLDS units on the network per Gateway)

Figure 4-3 - MRLDS Jumpers (Inside Lower Portion of Cover)

Figure 4-1 - Network Layout Example

Network Layout MRLDS Modbus Version (809-101x) • 5

Page 12 of the Emerson MRLDS user manual — 4.2.6 Modbus Output
Page 12 · click to enlarge
Page 12

4.2.3 Address Settings

the J2 or J1 sockets respective per the inside label.

Emerson MRLDS — 4.2.3 Address Settings diagram (page 12)
Fig. 13 · 4.2.3 Address Settings
Emerson MRLDS — 4.2.3 Address Settings diagram (page 12)
Fig. 14 · 4.2.3 Address Settings
Modbus Address Jumper SettingsJ5|J4|J3 100No jumpers installed 101 102 103 104 105 106 107 108 109 110 111

Figure 4-4 - Modbus Jumper Layout (Inside Lower Portion of Cover) Enlarged To Show Detail

Emerson MRLDS — 4.2.3 Address Settings diagram (page 12)
Fig. 15 · 4.2.3 Address Settings
Refrigerant TypeJ2|J1 R-22 R-404A R-134A

Table 4-2 - Refrigerant Jumper Settings

4.2.5 MRLDS Termination

The MRLDS has a built-in, on-board means of termi- nation, so an external termination block is not necessary for terminating. When the device is located at the end of a daisy chain, jumper JP6 for termination.

Emerson MRLDS — 4.2.5 MRLDS Termination diagram (page 12)
Fig. 16 · 4.2.5 MRLDS Termination

Table 4-1 - MRLDS Modbus Address Jumper Settings

4.2.4 Refrigerant Jumper Settings

The jumper settings for refrigerant types are located on the label inside the MRLDS sensor cover (shown in Fig- ure 1-1). Set the jumpers according to how they are indi- cated on the label.

The MRLDS supports three different refrigerant types. Select the desired refrigerant type by setting one jumper to

Figure 4-5 - MRLDS Termination (Inside Lower Left of Cover)

4.2.6 Modbus Output

See Table 4-3 below for Modbus registers in the MRLDS Unit. Baud rate: 19,200; each byte is 8 (eight)

Page 13 of the Emerson MRLDS user manual — 4.3.2 Gateway Connections
Page 13 · click to enlarge
Page 13

bits with no parity and 2 (two) stop bits.

Emerson MRLDS — 4.3 MRLDS Gateway diagram (page 13)
Fig. 17 · 4.3 MRLDS Gateway

SELECT I/O NET MODE OFF = IRLDS ON = 16AI

Figure 4-6 - I/O Network Modes

4.3.2 Gateway Connections

Factory Mode 4 (Lsb)

Up to 12 MRLDS units may be connected to the Gate- way board (P/N 810-3040). The Gateway board can inter- face with a site controller as a 16AI or as an IRLDS. If the site controller is an Einstein or E2, it is recommended to interface them as an IRLDS. Multiple Gateways can be used, each with up to 12 connected MRLDS units. 4.3.3 The Gateway Board

Trouble Mode 8 (Lsb)

0x0001 2 0 to 40

Emerson MRLDS — 4.3.2 Gateway Connections diagram (page 13)
Fig. 18 · 4.3.2 Gateway Connections

R-22 = 6 R-404A = 27 R-134a = 15

Modbus versions of the MRLDS must be connected to the 810-3040 MRLDS Gateway. The MRLDS Gateway can be mapped in either of two ways: it can be set up on I/O Net as an IRLDS application or as a 16AI board. Select by setting the Gateway’s dip switch #5 to the OFF or ON position (Figure 4-6).

Figure 4-7 - MRLDS Gateway Board Layout (810-3040)

MRLDS Gateway MRLDS Modbus Version (809-101x) • 7

Cal/Setup 2 (Lsb) · Gas Number

Page 14 of the Emerson MRLDS user manual — P/N 640-0056 640-0080
Page 14 · click to enlarge
Page 14
Emerson MRLDS — 4.3.4 Powering the Gateway Board diagram (page 14)
Fig. 19 · 4.3.4 Powering the Gateway Board
Emerson MRLDS — 4.3.4 Powering the Gateway Board diagram (page 14)
Fig. 20 · 4.3.4 Powering the Gateway Board

The Gateway Board communicates with the MRLDS via the Modbus network, which is connected to the Gate- way’s “Receiver Bus” network terminal. The Gateway communicates with the E2 via the RS485 I/O Network. 4.3.4 Powering the Gateway Board

Input Voltage 24VAC, Class 2, Center-Tapped 50/60Hz

Figure 4-8 - Pinout for the 56VA (640-0056) and 80VA (640- 0080) Transformers

Table 4-4 - Gateway Power Requirements

The Gateway board requires 24VAC power from a Class 2 center-tapped transformer. CPC supplies several sizes of center-tapped transformers for powering multiple 16AIs, 8ROs, and other RS485 peripheral boards.

4.3.5 Connecting the Gateway Board to the Einstein or REFLECS Network

Figure 4-8 shows how to connect the 56VA and 80VA transformers to the Gateway power connector.

Each E2, Einstein, or REFLECS site controller that will communicate with one or more MRLDS units must have a Gateway Board installed on its RS485 I/O Net- work. For Einstein controllers, this means the Gateway will be installed on the RS485 I/O Network; for RMCC, BEC, BCU, and other REFLECS products, the Gateway will be installed on the COM A or COM D network. 4.3.6 Wire Connections

P/N 640-0056 640-0080

Power Rating 56 VA 80 VA

Table 4-5 - Power Ratings for CPC Transformers

Using shielded three-conductor network cable (Belden #8641 or equivalent), connect the RS485 I/O Network wire to the three-terminal connector on the Gateway board as shown in Figure 4-9. For further information about how RS485 networks are configured, refer to your site

Power 5VA · Three-Board Six-Board

Page 15 of the Emerson MRLDS user manual — 4.3.7 Termination Settings
Page 15 · click to enlarge
Page 15

controller’s user manual.

Emerson MRLDS — 4.3.7 Termination Settings diagram (page 15)
Fig. 21 · 4.3.7 Termination Settings
Emerson MRLDS — 4.3.7 Termination Settings diagram (page 15)
Fig. 22 · 4.3.7 Termination Settings

Figure 4-9 - Connecting the Gateway to the E2 RS485 Network

To connect the Gateway to an MRLDS, feed the wires through the rectangular opening in the sensor base as indi- cated in Figure 1-1. Locate the RS485 connector and secure the wire leads to the connector orienting them as shown in Figure 4-10. Connect multiple MRLDS units in a daisy-chain configuration as shown in Figure 4-1.

Figure 4-11 -MRLDS Gateway Termination

4.3.8 Gateway Board I/O Net Addressing

Set the address on the I/O Network with switches 1-4. There can be more than one MRLDS Gateway with each supporting up to 12 MRLDS units.

Emerson MRLDS — 4.3.8 Gateway Board I/O Net Addressing diagram (page 15)
Fig. 23 · 4.3.8 Gateway Board I/O Net Addressing

Switch 5 indicates whether the MRLDS will be mapped as an IRLDS or 16AI. Set switch 5 to the OFF position for IRLDS emulation or to the ON position for 16AI emulation.

Emerson MRLDS — 4.3.8 Gateway Board I/O Net Addressing diagram (page 15)
Fig. 24 · 4.3.8 Gateway Board I/O Net Addressing

I/O NET MODE ON = 16AI OFF = IRLDS

Figure 4-10 - Connecting the Gateway to MODBUS

4.3.7 Termination Settings

As part of a site controller’s RS485 I/O (COM A or COM D) Network, a Gateway must be terminated if it is the end device of a daisy chain. The Gateway on the Mod- bus Network should always be terminated and always located at the end of the daisy chain.

Refer to the site controller’s user manual for informa- tion about daisy chain networks and how they are termi- nated.

To terminate the Gateway (the Modbus jumpers should always be terminated on the Gateway), set the receiver bus jumpers to the RIGHT position (Figure 4-11).

Figure 4-12 - Network Layout Example

MRLDS Gateway MRLDS Modbus Version (809-101x) • 9

Page 16 of the Emerson MRLDS user manual — 4.3.10.1 MRLDS Setup
Page 16 · click to enlarge
Page 16

4.3.9 Setting the Baud Rate Dip Switches

I/O ADDR: 1 FAIL I/O NET

Dip switches 6 and 7 control the baud rate at which the Gateway communicates with the site controller on the RS485 Network. These switches must be set to the same baud rate setting as the controller you are using (Einstein, RMCC, or E2), and defaults to 9600 baud. Dip switch 8 controls the baud rate at which the Gateway communicates with the MRLDS. For 9600 baud, set dip switch 8 to the OFF position. For 19200 baud, set dip switch 8 to the ON position (always use 19200 baud for MRLDS).

I/O BAUD: 9600

MOD BAUD: 19200

Figure 4-15 - Baud Rate/Address Screen

The Baud Rate/Address screen displays the Gateway I/O Network address (I/O ADDR), the I/O Network baud rate between the Gateway and the E2 (I/O BAUD), and the Modbus baud rate between the Gateway and the MRLDS devices (MOD BAUD). 4.3.10.2 Select Screen

GATEWAY DIP SWITCH

Press the down arrow again to navigate to the Select screen (or press F2). From the Select screen you can see status, setup, and firmware version information.

I/O NETWORK OR COM A AND D BAUD RATE

OFF = 9600 BAUD ON MODBUS ON = 19200 BAUD ON MODBUS ON

To select, press the right arrow until it appears next to SELECT and press 1, 2, or 3 in the list. Press the down arrow twice to move to the desired screen.

2 3 4 5 6 7 8 1

SELECT: 1 FAIL I/O NET

I/O NET BAUD RATE SETTINGS

1 - STATUS

ALWAYS USE 19200 BAUD WITH MRLDS

2 - SETUP/ONLINE 3 - FW REVISION

Figure 4-16 - Select Screen

Figure 4-13 - Dip Switch Settings for Gateway Baud Rate

4.3.10.3 Status Screen

4.3.10 Hand-Held Terminal Settings

1. The Status screen displays general status information about the MRLDS such as device numbering, count information (gas concentration in ppm), the type of refrigerant gas being monitored (MRLDS jumpers set by the user), and whether an alarm has been issued. An alarm indicates an MRLDS failure and that the MRLDS should be replaced. Call the CPC Service Department ( 770-4252724 ) to verify if the MRLDS unit should be replaced.

The hand-held terminal can be used to view status information, enable unit addresses, and is connected directly to the Gateway board via the hand-held terminal jack.

Possible states (ST) are:

MRLDS GATEWAY 810-3040 VER:1.10B03 ( PRESS ) FAIL I/O NET

  • WARMUP - MRLDS is warming up.
  • NORMAL - MRLDS has completed warm-up and is operating normally.
  • OFFLINE - MRLDS has lost communication.

Figure 4-14 - MRLDS HHT Home Screen

  • UNUSED - This address is not being used.

4.3.10.1 MRLDS Setup

  • FAIL - MRLDS has reported a fail state. Check the ALM field for specification.

From the HHT Home screen (F1), press the down arrow key to navigate to the Baud Rate/Address screen (Figure 4-15).

(GW to E2) · (GW to MRLDS) · 9600 19200

Page 17 of the Emerson MRLDS user manual — 100: ENABLE 1.12 FAIL I/O NET
Page 17 · click to enlarge
Page 17

4.3.11 Gateway Troubleshooting

If there is an issue with the Gateway board, the HHT Home screen (F1) can give status indicators to report the issue. The Home screen will display a warning if there is a failure associated with the I/O Network or flash on the Gateway board. Select the HHT Status screen to view sta- tus information for each MRLDS unit.

100. CNT: 1 ST: NORMAL FAIL I/O NET ALM: NONE

GAS: R134A

Figure 4-17 - Status Screen

4.4 Controller Setup for Modbus MRLDS

4.4.1 Mapping The MRLDS as an IRLDS Application

4.3.10.4 Setup/Online Screen

To set up communication on the I/O Network as an IRLDS application:

2. The Setup/Online screen displays the addressing of the devices and whether they are enabled. Press the right/ left arrows to select the first address in the list. Toggle the minus button to enable the first address in the list ( Figure 4-18 ). If communication is established, the screen will show “ON-L” indicating the unit is set up and online.
1. Log in to the E2 controller.
2. Press the Menu button to open the Main Menu.
3. Select 7. System Configuration .
4. Select 7. Network Setup .
5. Select 2. Connected I/O Boards & Controllers and add the desired number of MRLDS Gateways as IRLDS under I/O Net Devices . Up to 12 units can be connected to each Gateway.

100: ENBLE ON-L :: FAIL I/O NET

102:

103 104:

6. Press the J (Back) button and select 1. Online Status (Alt + N) to check the status.

Figure 4-18 - Setup/Online Screen

7. Go into the IRLDS application under General Setup and add the number of MRLDS units ( Num Channels field) connected to the Gateway. 4.4.2 Designating MRLDS as a 16AI Board
1. Log in to the E2 controller.
2. Press the Menu button to open the Main Menu.

4.3.10.5 Firmware Revision Screen

3. Select 7. System Configuration .
3. The Firmware Revision screen displays the address of the MRLDS unit with its associated firmware revision.
4. Select 7. Network Setup .
5. Select 2. Connected I/O Boards & Controllers and add the desired number of 16AI boards under I/O Net Devices .

100: ENABLE 1.12 FAIL I/O NET

6. Press the J (Back) button and select 1. Online Status (Alt + N) to check the status.
102.
103. 104:

For mapping the MRLDS unit as a 16AI board, first set dip switch #5 on the Gateway board to the ON position.

Figure 4-19 - Firmware Revision Screen

Follow Steps 1-6 above, but for Step 6 select the num- ber of 16AI boards to equal the number of MRLDS Gate-

Controller Setup for Modbus MRLDS MRLDS Modbus Version (809-101x) • 11

Page 18 of the Emerson MRLDS user manual — 4.4.4.1 REFLECS Setup for IRLDS IIs
Page 18 · click to enlarge
Page 18

4.4.4 RMCC Controllers Version 2.1 and Newer

ways.

Navigate to the controller’s Input Status screen and highlight the board and point that you wish to map. Press F1 to go to the Input Setup screen for that board/point. Each point will increase incrementally to correspond with each board. (For example, where the MRLDS is address 1 and the MRLDS address is 100, use board 1, point 1. For an MRLDS address of 101, use point 2.) 4.4.3 E2/Einstein Controllers

4.4.4.1 REFLECS Setup for IRLDS IIs

Set dip switch 8 to ON and follow the steps for setting up IRLDS IIs through the REFLECS controller interface:

1. Log on.
2. Press 7 for Configuration to reach the CONFIGURATION screen.

Next, set up the following parameters on the Input Setup screen:

Input Definitions should be set here to show how the sensor control is linked to the zone. The number of devices and IRLDS IIs are connected to the Gateway and enabled is the number of address slots the Gateway will use.

  • Sensor Type: Linear
  • Low End Point: 0.00000
3. Press 1 for Input Definitions to reach the INPUT DEFINITIONS screen.
  • Select Eng. Units: PPM
  • HighEnd Point: 4.80000
4. Pressing the down arrow several times will get you to the input list of SENS01-48 . Bd (board) is the address of the Gateway, Pt (point) is the zone and allows you to define where the sensor input comes from.
  • High Eng. Units: 1200.0000
Emerson MRLDS — 4.4.4.1 REFLECS Setup for IRLDS IIs diagram (page 18)
Fig. 25 · 4.4.4.1 REFLECS Setup for IRLDS IIs

The board number for the IRLDS II setup is the address of the Gateway. If there are three or less IRLDS II control- lers connected to a Gateway, the Gateway address = the IRLDS II address. However, if there are more than three IRLDS controllers, the second Gateway address will be the one entered for the board number, but the IRLDS II con- trollers are set 1 to 3 on the second Gateway.

5. Press 0 (zero) to go back to the CONFIGURATION screen.
6. Press 7 for I/O Brd Setup to reach the I/O BOARD MENU screen.
7. Press 2 to Set Device #’s .

The Gateway will react as three 16AI boards. The num- ber of IRLDS II controllers plus the real number of 16AIs = the total number of 16AIs to enter in the next step:

Figure 4-20 - Analog Input Screen Settings Example for E2

8. At the I/O BOARD DEVICE NUMBERS screen, press the down arrow key to reach Number 16AI Boards and enter the number of how many 16AI boards and IRLDS II controllers there are. Press Enter.
9. Arrow down to the I/O BOARD MENU and press 0 (zero) twice to go back to the MAIN MENU screen.
10. Press 4 for Sensor Control .
11. Press 2 for Setup --up to 48 sensor control programs are allowed. Select one of the 48 units and press Enter to reach the SENSOR SETUP screen.
12. Press the right arrow to move to the Name
Page 19 of the Emerson MRLDS user manual — 4.4.5.1 Input Definitions
Page 19 · click to enlarge
Page 19

field to change the name, and press the down or right arrow to move to the (sensor) Type field. Use the “.” and “—” keys to scroll through the options and select IRLDS. (The Gain and Offset parameters are automatically configured for you.)

Locate the screen in the BEC or RMCC where sensors are set up. This is usually a menu option in the Sensors Menu, which may be reached from the Main Menu.

The 0-4.8V signal is a linear signal representing a mea- sured concentration of 0-1200 ppm, and a voltage of 5.0V indicates a fault. In order for the REFLECS to read these voltages correctly, the REFLECS sensor inputs must be configured as linear sensors.

13. Use the arrow keys to move off the active fields and press 0 (zero) twice to go back to the main screen. 4.4.5 BEC and RMCC Controllers Less Than Version 2.1

A name for the sensor input may be entered in the Name field. Since each IRLDS zone is set up with two REFLECS sensor inputs, choose names for each input that distinguish the input’s function. For example, the sensor input set up to read leak concentrations on zone 1 should have a name like REFR LK ZN 01, and the input set up to monitor fault sta- tus should have a name like FAULT ZN 01.

4.4.5.1 Input Definitions

Emerson MRLDS — 4.4.5.1 Input Definitions diagram (page 19)
Fig. 26 · 4.4.5.1 Input Definitions

All sensor inputs connected to an IRLDS should be set up as linear sensors. Enter (L)inear in the Type field.

The logging interval is the amount of time between log entries in the REFLECS’s Data Log.

Locate the screens in the BEC or RMCC that are used to define input board and points. This is usually achieved by pressing 7 then 1 from the Main Menu. Press the DOWN ARROW key several times until the SENS01- SENS08 inputs are shown.

When choosing a logging interval, keep in mind the amount of time it takes an IRLDS to go through an entire cycle of samplings. For example, a 16-valve IRLDS with 30 second sampling times for each zone takes a total of eight minutes to sample all zones. Choosing a logging in- terval smaller than the IRLDS’s cycle time will simply clutter the REFLECS data log with multiple copies of the same sample. 4.4.5.3 Sensor Setpoints

The 16AI connected to the IRLDS’s output terminals must be set up in the REFLECS’s system software. If the 16AI was given a unique board number by setting the dip switch S3, and wired to the terminals so that each zone number corresponds to a 16AI point number (zone 01 con- nected to point 01, for example), these board and point ad- dresses must now be entered into the REFLECS.

Emerson MRLDS — 4.4.5.1 Input Definitions diagram (page 19)
Fig. 27 · 4.4.5.1 Input Definitions

SENSOR SETPOINTS LINEAR INPUT 12:00 #:01 Status:OFF Name:REFR LK ZN 01 Stay ON for:000 min Eng.Unit:PPM Using Diff Of 01 00 00 00 0 Of 0 Gain 250 Offset 00000 mv ON: 0 Dly: 0000 OFF:0 Dly:0000 =PREV =NEXT ->=SET-DATA 0=MENU

The screen above shows how the board and point ad- dresses for zone 1 would be set up for a 16AI board num- bered 1. Both SENS01 and SENS02 are set up as 01:01 so that SENS01 can monitor concentration and SENS02 can monitor fault status.

Set up the remaining sensors using the instructions giv- en above. For each point on the 16AI, set up two sensors with the same addresses. 4.4.5.2 Sensor Setup

Locate the screen in the BEC or RMCC where sensor set points are specified. This is usually a menu option in the Sensors Menu, which may be reached from the Main Menu.

Emerson MRLDS — 4.4.5.1 Input Definitions diagram (page 19)
Fig. 28 · 4.4.5.1 Input Definitions

SENSOR SETUP 12:00 #:01 Status:OFF Name:REFR LK ZN 01 Type: Linear

After the linear sensors have been set up, the REFLECS must be told how to interpret the linear voltage given by the IRLDS.

(T)mp (1)00 (5)00 (R)fLeak (K)Watt (H)um (2)00 (D)ig (L)inear L(Q)Lev (6)450 Tmp Dew(P)nt Logging Interval (HH:MM:SS): 00:03:00 =PREV =NEXT ->=SET-DATA 0=MENU

Eng. Unit

The REFLECS does not require any specific engineer- ing unit to be specified for sensor values. However, for eas- ier reading of status screens and data logs, “PPM” should be entered for sensor inputs that read concentration, and

Controller Setup for Modbus MRLDS MRLDS Modbus Version (809-101x) • 13

Name · Type · Logging Interval

Page 20 of the Emerson MRLDS user manual — 5.2.1 IRLDS Mode
Page 20 · click to enlarge
Page 20

5 Diagnostics

“MV” should be entered for sensor inputs that read fault status.

Since the output terminals emit one volt for every 250 ppm of refrigerant detected, the gain for the refrigerant leak sensors must be set to 250 and the Offset to 0.

5.1 MRLDS LED Indicators

The sensors configured to detect faults must be given a gain of 1000; this way, the REFLECS can be set up to alarm whenever it detects a 5000 mV signal. 4.4.5.4 Alarm Setpoints

The MRLDS has three LEDs for quick status indica- tion.

Emerson MRLDS — 5.1 MRLDS LED Indicators diagram (page 20)
Fig. 29 · 5.1 MRLDS LED Indicators
Emerson MRLDS — 5.1 MRLDS LED Indicators diagram (page 20)
Fig. 30 · 5.1 MRLDS LED Indicators

Red Flashes at 0.5 Hz during start-up Turns ON solid if concentration reading exceeds 50 ppm

Yellow Flashes at 0.5 Hz if power sup- plied is outside set limits Turns ON solid during other fault conditions

Locate the screen in the BEC or RMCC where sensor alarm set points are specified. This is usually a menu option in the Sensors Menu, which may be reached from the Main Menu.

Table 5-1 - MRLDS LED Status

For analog output models, a fault is signaled by setting the voltage to 0.5V, which indicates the MRLDS should be be replaced. Call the CPC Service Department (770-425- 2724) to verify if the MRLDS unit should be replaced.

The REFLECS should now be capable of interpreting the 0-4.8V output voltage as a refrigerant concentration of 0-1200 ppm and the 5V output voltage as a fault. The de- sired alarm set points must now be specified. When set up correctly, alarms will appear in the REFLECS Alarm log as “Hi Sensor” alarms (refer to the REFLECS manual for alarm descriptions).

5.2 E2 Alarming

AlarmsHigh

5.2.1 IRLDS Mode

In this field, specify a high alarm setpoint for refriger- ant leak alarms between 0 and 1200 ppm. For fault status alarms, enter a setpoint of 4960 mV (slightly below 5V, as a precautionary measure).

If any one or all of the MRLDS sensors encounters a problem, the IRLDS application will alarm and all cell outputs will show NONE. For details on which individual unit is in alarm, go to the MRLDS Gateway and check the Status screen on the HHT. 5.2.2 16AI Mode

The value entered in the Alarms Dly field is the number of minutes the sensor reading must be above the Alarms:High set point before the REFLECS may generate a leak alarm

If an MRLDS has lost communication, the input will go to 1250 PPM, which should force an alarm if enabled. If all MRLDS sensors lose communication, the 16AI will go offline. Check the Status screen on the HHT for details.

When choosing an alarm delay, keep in mind the amount of time it takes an IRLDS to complete a sampling cycle. For example, a 16-valve IRLDS with 30 second sam- pling times for each zone takes a total of eight minutes to sample all zones. Choosing an alarm delay smaller than the IRLDS’s cycle time will cause an alarm to be generated af- ter only one high reading is taken.

Gain and Offset · Alarms/Notices Dly

Ask about the Emerson MRLDS

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson MRLDS

Be the first to ask — other owners or our team will answer.

Original document

Emerson MRLDS manual PDF

20 pages·594 KB·Stud Sensor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…