Page 1 of the Emerson 650VA user manual — NEMA 5-15R
Page 1 · click to enlarge
Page 1
Emerson 650VA — Important Safety Instructions diagram (page 1)
Fig. 1 · Important Safety Instructions

I MPORTANT S AFETY I NSTRUCTIONS SAVE THESE INSTRUCTIONS

  • Connect the UPS only to an earthed / grounded outlet that meets national and local electrical safety guidelines.
  • Locate the UPS near a wall outlet. Do not use an extension cord between the UPS and the outlet.
  • The Liebert PSA has been designed for small office/home office use only; it is NOT recommended for use in life-support applications.
  • In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
  • Do not attach power strips or surge suppressors to the UPS.
  • Do not attempt to service any parts inside the UPS except the batteries. Failure to adhere to this could cause personal injury or equipment malfunction and void the warranty.
  • For technical support:
  • Visit <a href="http://www.liebert.com" rel="nofollow noopener" target="_blank">www.liebert.com</a> or
  • Send an e-mail to upstech@<a href="http://emersonnetworkpower.com" rel="nofollow noopener" target="_blank">emersonnetworkpower.com</a> .
  • This manual contains important instructions that should be followed during installation and maintenance of the UPS.
  • Intended for installation in a controlled environment.
  • Maximum ambient temperature 104°F (40°C).

! CAUTION To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the national code, ANSI/NFPA 70.

  • Do not connect equipment that may overload the UPS or demand half-wave rectification, such as a laser printer.

S ETUP

Step 1 Inspect the Package

Step 5 Check the Site Wiring Fault Indicator

Emerson 650VA — S ETUP diagram (page 1)
Fig. 2

Inspect the package and the UPS upon receipt. Notify the carrier and dealer of visible damage.

See figure at right for the location of the Site Wiring Indicator on the rear of the UPS.

  • Check the rear of the UPS to make sure the Site Wiring Fault indicator is NOT illuminated.
Emerson 650VA — S ETUP diagram (page 1)
Fig. 3

Step 6 Connect the Loads

CD

The UPS has three battery backup outlets that provide power when the UPS operates on bat- tery (see Figure 2 below).

  • Plug the loads into the battery backup outlets on the rear of the UPS.

UPS

Step 2 Decide Where to Place the UPS

The UPS must be placed indoors, protected from water, direct sunlight and excessive heat.

Step 7 Connect the Network Surge Protection

The UPS has two RJ-45 jacks for network lines (see Figure 2 below).

Provide at least 4" (100mm) of clearance on all sides of the unit for proper ventilation.

  • Connect a single-line network cable into the RJ-45 network surge protection IN jack on the rear of the UPS.
  • Connect an RJ-45 cable from the OUT jack on the rear of the UPS to a port on a PC or network device such as a router.

Step 3 Charge the UPS Battery Before Use

The UPS battery is not charged before shipping. It MUST be charged before use.

  • Connect the UPS power cord to a wall outlet and charge for at least eight hours.

Step 8 Set Up Liebert shutdown software

To start using the Liebert shutdown software:

Step 4 Start the UPS

  • Install the Liebert shutdown software. See the software user manual for installation instructions.
  • Connect one end of the USB cable (supplied) to the USB port on the rear of the UPS. Connect the other end to a USB port on the computer. See the software user manual for operating instructions.

After the battery is fully charged:

  • Turn on the UPS by pressing the On/Off button (see Figure 1 below).

LED 1 should be illuminated (green), indicating the UPS is operating in Normal Mode.

UPS C ONTROLS AND C ONNECTIONS

Figure 2 - Rear Panel Figure 1 - Front Panel LEDs

Emerson 650VA — Figure 2 - Rear Panel Figure 1 - Front Panel LEDs diagram (page 1)
Fig. 4 · Figure 2 - Rear Panel Figure 1 - Front Panel LEDs

Site Wiring Fault indicator

LED 2 (red = fault; amber = overload)

RJ-45 jacks (2) - network protection

NEMA 5-15P

Battery backup outlets (3) NEMA 5-15R

NEMA 5-15R

UPS Status, Alarm Conditions and Alerts

ConditionLEDColorSolid/Flashing Normal ModeLED 1GreenSolid (steady glow) Battery ModeLED 1GreenFlashes every 3 seconds Battery LowLED 1GreenFlashes every 1 second till end of discharge (EOD) OverloadLED 2AmberSolid (steady glow) until load drops or breaker trips Battery ReplacementLED 2RedFlashes every 1 second for 5 seconds only FaultLED 2RedSolid (steady glow) until UPS shuts down after 5 seconds
Emerson 650VA — NEMA 5-15R diagram (page 1)
Fig. 5
Show 13 more labels / short text on this page
Liebert shutdown · software · Quick-start · guide · USB cable · On/Off button · Overload symbol · USB interface · LED 1 (green) · Utility symbol · Input breaker · Fault symbol · Surge outlet (1)
Page 2 of the Emerson 650VA user manual — S PECIFICATIONS
Page 2 · click to enlarge
Page 2

R EPLACING THE B ATTERY

To replace the battery:

1. Turn off all connected loads, then turn off the UPS (batteries are NOT hot-swappable).

Steps 2 and 3

2. Use a Phillips head screwdriver to remove the two screws from the bottom edge of the front panel.

Steps 4 and 5

3. Slide the panel downward and remove it.
Emerson 650VA — R EPLACING THE B ATTERY diagram (page 2)
Fig. 6
4. Gently pull the battery out of the UPS.
5. Remove the black wire from the negative (-) terminal and the red wire from the positive (+) terminal.
6. Verify that the replacement battery matches the dimensions and battery type in the Specifications section below.
7. Connect the battery leads to the new battery. Be sure to reconnect the red wire to the positive (+) terminal and the black wire to the negative (-) terminal.
8. Slide the battery into the UPS.
9. Close the front panel and replace the two screws from Step 2 .

Dispose of the old battery properly at an appropriate recycling facility.

T ROUBLESHOOTING

If the UPS malfunctions during operation, check the following chart for proper adjustment. For further assistance, please contact your local Emerson Network Power representative.

ProblemPossible CausesSolutions Utility power is normal, but LED 1 is not illuminated.The UPS may not be turned on. • Pres The power cord may not be connected properly. • Conn The upstream input circuit breaker may be tripped. • Reses the On/Off button to turn on the UPS. ect the power cord securely into a wall outlet. t the input circuit breaker. LED 1 flashes (green) every 3 seconds, but there is no output power.Battery voltage may be too low. • Recharge the UPS for 8 hours. Alarm buzzer beeps continuously although utility power is normal.The UPS may be overloaded (check LED 2). • Disconnect some equipment from the UPS. UPS does not provide expected backup time.The UPS battery reached end of life. • Replace the internal battery. The UPS is on and connected to input power, but fails to operate properly.• If util Utility power may be outside the unit’s operating range. poweity power is normal, try reconnecting input r and restarting the UPS.

S PECIFICATIONS

Model NumberPSA500MT3-120U Capacity (VA/W)500/300 Net Weight, lb. (kg)14.1 (6.4) Shipping Weight, lb. (kg)15.9 (7.2) Dimensions - W x D x H, in. (mm) On-Line Input Voltage On-Line Frequency Output Voltage (Utility Power Normal) Output Voltage (Battery Operation) On-Battery Wave Form Battery Type - VDC x Ah x Quantity Typical Recharge Time Battery Run Time* - Full Load Battery Run Time* - Half Load Audible and Visual Backup Outlets Surge Outlets Operating Temperature, °F (°C) Storage Temperature, °F (°C) Operating / Storage Relative Humidity EMI Classification
Emerson 650VA — S PECIFICATIONS diagram (page 2)
Fig. 7

* Battery run time may vary depending on load

Emerson 650VA — S PECIFICATIONS diagram (page 2)
Fig. 8

© 2008 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-23300_REV0_04-08

1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Utility power is normal, but LED 1 is not illuminated.The UPS may not be turned on. • Pres The power cord may not be connected properly. • Conn The upstream input circuit breaker may be tripped. • Reses the On/Off button to turn on the UPS. ect the power cord securely into a wall outlet. t the input circuit breaker. p.2
LED 1 flashes (green) every 3 seconds, but there is no output power.Battery voltage may be too low. • Recharge the UPS for 8 hours. p.2
Alarm buzzer beeps continuously although utility power is normal.The UPS may be overloaded (check LED 2). • Disconnect some equipment from the UPS. p.2
UPS does not provide expected backup time.The UPS battery reached end of life. • Replace the internal battery. p.2
The UPS is on and connected to input power, but fails to operate properly.• If util Utility power may be outside the unit’s operating range. poweity power is normal, try reconnecting input r and restarting the UPS. p.2

Ask about the Emerson 650VA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson 650VA

Be the first to ask — other owners or our team will answer.

Original document

Emerson 650VA manual PDF

2 pages·650 KB·Power Supply·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…