Go to page of 24
Save this manual for future reference. UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea.
3 104256 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
5 104256 OWNER’S MANUAL WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide ad- equate combustion and ventila- tion air by one of the methods described in the National Fuel Gas Code, ANSI Z223.
6 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Width 18" 17" 14" 20" 24" 17" 14&.
7 104256 OWNER’S MANUAL INST ALLA TION Continued NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fireplace opening is not needed.
8 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ Figure 7 - Minimum Mantel Clearances When Using Hood Minimum Non- Combustible Material 8" Min.
9 104256 OWNER’S MANUAL INST ALLA TION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of non combustible material.
10 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane supply.
11 104256 OWNER’S MANUAL INST ALLA TION Continued The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur.
12 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ ON POSITION OFF POSITION INST ALLA TION Continued Figure 15 - Manual Shutoff Valve Open Closed Manual Shutoff Valve Figure 16 - Ch.
13 104256 OWNER’S MANUAL INST ALLA TION Continued WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal in- jury. INSTALLING LOGS For Vintage Oak Model Each log is marked with a number.
14 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ 1. STOP! Read the safety inf ormation above. 2. Make sur e manual shutoff valve is fully open.
15 104256 OWNER’S MANUAL OPERA TING HEA TER Continued TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Press in and tur n control knob clock- wise Clockwise to the HIGH position. 2 . T urn the contr ol knob clockwise Clockwise to the PILOT position.
16 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.
17 104256 OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial opera- tion Heater produces a whistling noise when burner is lit Moisture/condensation noticed on windows REMEDY 1.
18 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
19 104256 OWNER’S MANUAL SPECIFICA TIONS Golden Oak Golden Oak Vintage Oak Vintage Oak and Birch and Birch 18" Variable 24" Variable 18" Variable 24 ” , 30 ” , and 36" Manual.
20 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX ™ VINTAGE OAK MODELS VYS18P AND VYS24P 4 1 2 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19.
21 104256 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NUMBER FOR NO. VYS18P VYS24P DESCRIPTION QTY.
22 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX ™ GOLDEN OAK AND BIRCH LOG MODELS VYD18P, VYBD18P, VYD24P, VYBD24P,VYD30P, VYBD30P, AN.
23 104256 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NUMBER FOR NO. VYD18P VYBD18P VYD24P VYBD24P VYD30P VYBD30P VYD36P DESCRIPTION QTY.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
An important point after buying a device Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER you will learn all the available features of the product, as well as information on its operation. The information that you get Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER will certainly help you make a decision on the purchase.
If you already are a holder of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER.
However, one of the most important roles played by the user manual is to help in solving problems with Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center