EN
Dell logo
Official user manual

Dell UCPM-800

39 pages·1.1 MB·Home Theater Server·PDF·ENDEFRITNLJA
Dell UCPM-800
Table of Contents 96 sections Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guide · About The Shared PERC 8 Card · Configurations of the Shared PERC 8 card · Specifications of a Shared PERC 8 card · … ShowHide
Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guidep.3About The Shared PERC 8 Cardp.6Configurations of the Shared PERC 8 cardp.6Specifications of a Shared PERC 8 cardp.7Supported Operating Systemsp.9Best Practices For Shared PERC 8p.9Related Documentationp.9Locating your system Service Tagp.10Contacting Dellp.10Documentation Feedbackp.11Shared PERC 8 Card Featuresp.12Physical Disk Power Managementp.12Consistency Checksp.12Virtual Disk Initializationp.12Background Initialization Of Virtual Disksp.13Full Initialization Of Virtual Disksp.13Fast Initialization Of Virtual Disksp.13Physical Disk Roamingp.13Using Physical Disk Roamingp.14FastPathp.14Virtual Disk Migrationp.14Migrating Virtual Disks If The Target System Is Turned Offp.15Migrating Virtual Disks If The Target System Is Turned Onp.15Virtual Disk Cache Policiesp.15Virtual Disk Write Cache Policiesp.16Write-Backp.16Conditions Under Which Write-Back Is Employedp.16Conditions Under Which Forced Write-Back With No Battery Is Employedp.16Write-throughp.16Conditions under which write-through is employedp.17Virtual Disk Read Cache Policiesp.17Physical Disk Write Cache Policyp.17Fault Tolerancep.17The SMART Featurep.18Patrol Readp.18Physical disk failure detectionp.19Physical Disk Hot Swappingp.19Auto Replacement Of A Virtual Disk Member And Revertible Hot Sparesp.19Shared PERC 8 Card Cache Preservationp.19Battery Transparent Learn Cyclep.20The Controller Failover Featurep.20Multipath Supportp.21Configuring Multipath Support In Windowsp.21Configuring Multipath Support In VMWarep.21Multipath support in Linuxp.21Deploying The Shared PERC 8 Cardp.22Installing A New Shared PERC 8 Cardp.22Replacing A Shared PERC 8 Cardp.22Prerequisites For Removing The Shared PERC 8 Cardp.23Removing The Shared PERC 8 Cardp.23Installing The Shared PERC 8 Cardp.25Post-Installation Tasks For Shared PERC 8 Cardp.25Firmware installation or updatep.26Updating firmwarep.26Driver Installationp.27Downloading Drivers and Firmware For Shared PERC 8 From The Dell Support Website For All Operating Systemsp.27Downloading Drivers From The Dell Systems Service And Diagnostic Tools Media For Windowsp.27Installing Or Updating Windows Drivers For Shared PERC 8p.28Installing Or Updating Linux Drivers For Shared PERC 8p.29Installing Or Updating The Driver Package On RHEL Using KMOD Supportp.29Installing Or Updating The Driver Package On SLES Using KMP Supportp.29Installing Or Updating VMware Drivers For Shared PERC 8p.29Management Applications For Shared PERC 8 Cardp.30Troubleshootingp.31Performance variations between write-back and write-through cache modesp.31Shared PERC 8 Card Boots Into Safe Modep.31Degraded State Of Virtual Disksp.32General Issuesp.32Shared PERC 8 Card Has Yellow Exclamation Mark In Device Managerp.32Shared PERC 8 Card Not Seen In Device Managerp.32Critical Errors Or Disk Warning Messages Seen In The Windows Event Logp.32Shared PERC 8 Cards Fail To Functionp.33Physical disk issuesp.33Incorrect Number of Virtual Disks Displayed In Windows Disk Managerp.33Physical Disk In Failed Statep.33Unable to rebuild a fault tolerant virtual diskp.33Fatal Error Or Data Corruption Reportedp.34Physical Disk Displayed As Blocked By Management Applicationp.34Multiple Disks Become Inaccessiblep.34Rebuilding A Failed Physical Diskp.34Virtual Disk Fails During Rebuild Using A Global Hot Sparep.35Virtual Disk Fails During Rebuild Using A Dedicated Hot Sparep.35Physical disk takes a long time to rebuildp.35Controller cache issuesp.35SMART Errorsp.36SMART Error Detected On A Physical Disk In A Redundant Virtual Diskp.36SMART Error Detected On A Physical Disk In A Non-Redundant Virtual Diskp.37Auto Replacement Member Errorsp.37Source Disk Failsp.37Target Disk Failsp.37General Disk Failsp.37Hard-Drive Indicator Patternsp.38Getting helpp.39Contacting Dellp.39Locating your system Service Tagp.39Documentation feedbackp.39
Page 1 of the Dell UCPM-800 user manual
Page 1 · click to enlarge
Page 1

Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guide

Regulatory ModelUCPM-800
Page 2 of the Dell UCPM-800 user manual — Notes, Cautions, and Warnings
Page 2 · click to enlarge
Page 2

Notes, Cautions, and Warnings

Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

Rev. A03

2014 - 11

Page 3 of the Dell UCPM-800 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guidep.3About The Shared PERC 8 Cardp.6Configurations of the Shared PERC 8 cardp.6Specifications of a Shared PERC 8 cardp.7Supported Operating Systemsp.9Best Practices For Shared PERC 8p.9Related Documentationp.9Locating your system Service Tagp.10Contacting Dellp.10Documentation Feedbackp.11Shared PERC 8 Card Featuresp.12Physical Disk Power Managementp.12Consistency Checksp.12Virtual Disk Initializationp.12Background Initialization Of Virtual Disksp.13Full Initialization Of Virtual Disksp.13Fast Initialization Of Virtual Disksp.13Physical Disk Roamingp.13Using Physical Disk Roamingp.14FastPathp.14Virtual Disk Migrationp.14Migrating Virtual Disks If The Target System Is Turned Offp.15Migrating Virtual Disks If The Target System Is Turned Onp.15Virtual Disk Cache Policiesp.15Virtual Disk Write Cache Policiesp.16Write-Backp.16Conditions Under Which Write-Back Is Employedp.16Conditions Under Which Forced Write-Back With No Battery Is Employedp.16Write-throughp.16Conditions under which write-through is employedp.17Virtual Disk Read Cache Policiesp.17Physical Disk Write Cache Policyp.17Fault Tolerancep.17The SMART Featurep.18Patrol Readp.18Physical disk failure detectionp.19Physical Disk Hot Swappingp.19Auto Replacement Of A Virtual Disk Member And Revertible Hot Sparesp.19Shared PERC 8 Card Cache Preservationp.19Battery Transparent Learn Cyclep.20The Controller Failover Featurep.20Multipath Supportp.21Configuring Multipath Support In Windowsp.21Configuring Multipath Support In VMWarep.21Multipath support in Linuxp.21Deploying The Shared PERC 8 Cardp.22Installing A New Shared PERC 8 Cardp.22Replacing A Shared PERC 8 Cardp.22Prerequisites For Removing The Shared PERC 8 Cardp.23Removing The Shared PERC 8 Cardp.23Installing The Shared PERC 8 Cardp.25Post-Installation Tasks For Shared PERC 8 Cardp.25Firmware installation or updatep.26Updating firmwarep.26Driver Installationp.27Downloading Drivers and Firmware For Shared PERC 8 From The Dell Support Website For All Operating Systemsp.27Downloading Drivers From The Dell Systems Service And Diagnostic Tools Media For Windowsp.27Installing Or Updating Windows Drivers For Shared PERC 8p.28Installing Or Updating Linux Drivers For Shared PERC 8p.29Installing Or Updating The Driver Package On RHEL Using KMOD Supportp.29Installing Or Updating The Driver Package On SLES Using KMP Supportp.29Installing Or Updating VMware Drivers For Shared PERC 8p.29Management Applications For Shared PERC 8 Cardp.30Troubleshootingp.31Performance variations between write-back and write-through cache modesp.31Shared PERC 8 Card Boots Into Safe Modep.31Degraded State Of Virtual Disksp.32General Issuesp.32Shared PERC 8 Card Has Yellow Exclamation Mark In Device Managerp.32Shared PERC 8 Card Not Seen In Device Managerp.32Critical Errors Or Disk Warning Messages Seen In The Windows Event Logp.32Shared PERC 8 Cards Fail To Functionp.33Physical disk issuesp.33Incorrect Number of Virtual Disks Displayed In Windows Disk Managerp.33Physical Disk In Failed Statep.33Unable to rebuild a fault tolerant virtual diskp.33Fatal Error Or Data Corruption Reportedp.34Physical Disk Displayed As Blocked By Management Applicationp.34Multiple Disks Become Inaccessiblep.34Rebuilding A Failed Physical Diskp.34Virtual Disk Fails During Rebuild Using A Global Hot Sparep.35Virtual Disk Fails During Rebuild Using A Dedicated Hot Sparep.35Physical disk takes a long time to rebuildp.35Controller cache issuesp.35SMART Errorsp.36SMART Error Detected On A Physical Disk In A Redundant Virtual Diskp.36SMART Error Detected On A Physical Disk In A Non-Redundant Virtual Diskp.37Auto Replacement Member Errorsp.37Source Disk Failsp.37Target Disk Failsp.37General Disk Failsp.37Hard-Drive Indicator Patternsp.38Getting helpp.39Contacting Dellp.39Locating your system Service Tagp.39Documentation feedbackp.39
Page 4 of the Dell UCPM-800 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guidep.3About The Shared PERC 8 Cardp.6Configurations of the Shared PERC 8 cardp.6Specifications of a Shared PERC 8 cardp.7Supported Operating Systemsp.9Best Practices For Shared PERC 8p.9Related Documentationp.9Locating your system Service Tagp.10Contacting Dellp.10Documentation Feedbackp.11Shared PERC 8 Card Featuresp.12Physical Disk Power Managementp.12Consistency Checksp.12Virtual Disk Initializationp.12Background Initialization Of Virtual Disksp.13Full Initialization Of Virtual Disksp.13Fast Initialization Of Virtual Disksp.13Physical Disk Roamingp.13Using Physical Disk Roamingp.14FastPathp.14Virtual Disk Migrationp.14Migrating Virtual Disks If The Target System Is Turned Offp.15Migrating Virtual Disks If The Target System Is Turned Onp.15Virtual Disk Cache Policiesp.15Virtual Disk Write Cache Policiesp.16Write-Backp.16Conditions Under Which Write-Back Is Employedp.16Conditions Under Which Forced Write-Back With No Battery Is Employedp.16Write-throughp.16Conditions under which write-through is employedp.17Virtual Disk Read Cache Policiesp.17Physical Disk Write Cache Policyp.17Fault Tolerancep.17The SMART Featurep.18Patrol Readp.18Physical disk failure detectionp.19Physical Disk Hot Swappingp.19Auto Replacement Of A Virtual Disk Member And Revertible Hot Sparesp.19Shared PERC 8 Card Cache Preservationp.19Battery Transparent Learn Cyclep.20The Controller Failover Featurep.20Multipath Supportp.21Configuring Multipath Support In Windowsp.21Configuring Multipath Support In VMWarep.21Multipath support in Linuxp.21Deploying The Shared PERC 8 Cardp.22Installing A New Shared PERC 8 Cardp.22Replacing A Shared PERC 8 Cardp.22Prerequisites For Removing The Shared PERC 8 Cardp.23Removing The Shared PERC 8 Cardp.23Installing The Shared PERC 8 Cardp.25Post-Installation Tasks For Shared PERC 8 Cardp.25Firmware installation or updatep.26Updating firmwarep.26Driver Installationp.27Downloading Drivers and Firmware For Shared PERC 8 From The Dell Support Website For All Operating Systemsp.27Downloading Drivers From The Dell Systems Service And Diagnostic Tools Media For Windowsp.27Installing Or Updating Windows Drivers For Shared PERC 8p.28Installing Or Updating Linux Drivers For Shared PERC 8p.29Installing Or Updating The Driver Package On RHEL Using KMOD Supportp.29Installing Or Updating The Driver Package On SLES Using KMP Supportp.29Installing Or Updating VMware Drivers For Shared PERC 8p.29Management Applications For Shared PERC 8 Cardp.30Troubleshootingp.31Performance variations between write-back and write-through cache modesp.31Shared PERC 8 Card Boots Into Safe Modep.31Degraded State Of Virtual Disksp.32General Issuesp.32Shared PERC 8 Card Has Yellow Exclamation Mark In Device Managerp.32Shared PERC 8 Card Not Seen In Device Managerp.32Critical Errors Or Disk Warning Messages Seen In The Windows Event Logp.32Shared PERC 8 Cards Fail To Functionp.33Physical disk issuesp.33Incorrect Number of Virtual Disks Displayed In Windows Disk Managerp.33Physical Disk In Failed Statep.33Unable to rebuild a fault tolerant virtual diskp.33Fatal Error Or Data Corruption Reportedp.34Physical Disk Displayed As Blocked By Management Applicationp.34Multiple Disks Become Inaccessiblep.34Rebuilding A Failed Physical Diskp.34Virtual Disk Fails During Rebuild Using A Global Hot Sparep.35Virtual Disk Fails During Rebuild Using A Dedicated Hot Sparep.35Physical disk takes a long time to rebuildp.35Controller cache issuesp.35SMART Errorsp.36SMART Error Detected On A Physical Disk In A Redundant Virtual Diskp.36SMART Error Detected On A Physical Disk In A Non-Redundant Virtual Diskp.37Auto Replacement Member Errorsp.37Source Disk Failsp.37Target Disk Failsp.37General Disk Failsp.37Hard-Drive Indicator Patternsp.38Getting helpp.39Contacting Dellp.39Locating your system Service Tagp.39Documentation feedbackp.39
Page 5 of the Dell UCPM-800 user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guidep.3About The Shared PERC 8 Cardp.6Configurations of the Shared PERC 8 cardp.6Specifications of a Shared PERC 8 cardp.7Supported Operating Systemsp.9Best Practices For Shared PERC 8p.9Related Documentationp.9Locating your system Service Tagp.10Contacting Dellp.10Documentation Feedbackp.11Shared PERC 8 Card Featuresp.12Physical Disk Power Managementp.12Consistency Checksp.12Virtual Disk Initializationp.12Background Initialization Of Virtual Disksp.13Full Initialization Of Virtual Disksp.13Fast Initialization Of Virtual Disksp.13Physical Disk Roamingp.13Using Physical Disk Roamingp.14FastPathp.14Virtual Disk Migrationp.14Migrating Virtual Disks If The Target System Is Turned Offp.15Migrating Virtual Disks If The Target System Is Turned Onp.15Virtual Disk Cache Policiesp.15Virtual Disk Write Cache Policiesp.16Write-Backp.16Conditions Under Which Write-Back Is Employedp.16Conditions Under Which Forced Write-Back With No Battery Is Employedp.16Write-throughp.16Conditions under which write-through is employedp.17Virtual Disk Read Cache Policiesp.17Physical Disk Write Cache Policyp.17Fault Tolerancep.17The SMART Featurep.18Patrol Readp.18Physical disk failure detectionp.19Physical Disk Hot Swappingp.19Auto Replacement Of A Virtual Disk Member And Revertible Hot Sparesp.19Shared PERC 8 Card Cache Preservationp.19Battery Transparent Learn Cyclep.20The Controller Failover Featurep.20Multipath Supportp.21Configuring Multipath Support In Windowsp.21Configuring Multipath Support In VMWarep.21Multipath support in Linuxp.21Deploying The Shared PERC 8 Cardp.22Installing A New Shared PERC 8 Cardp.22Replacing A Shared PERC 8 Cardp.22Prerequisites For Removing The Shared PERC 8 Cardp.23Removing The Shared PERC 8 Cardp.23Installing The Shared PERC 8 Cardp.25Post-Installation Tasks For Shared PERC 8 Cardp.25Firmware installation or updatep.26Updating firmwarep.26Driver Installationp.27Downloading Drivers and Firmware For Shared PERC 8 From The Dell Support Website For All Operating Systemsp.27Downloading Drivers From The Dell Systems Service And Diagnostic Tools Media For Windowsp.27Installing Or Updating Windows Drivers For Shared PERC 8p.28Installing Or Updating Linux Drivers For Shared PERC 8p.29Installing Or Updating The Driver Package On RHEL Using KMOD Supportp.29Installing Or Updating The Driver Package On SLES Using KMP Supportp.29Installing Or Updating VMware Drivers For Shared PERC 8p.29Management Applications For Shared PERC 8 Cardp.30Troubleshootingp.31Performance variations between write-back and write-through cache modesp.31Shared PERC 8 Card Boots Into Safe Modep.31Degraded State Of Virtual Disksp.32General Issuesp.32Shared PERC 8 Card Has Yellow Exclamation Mark In Device Managerp.32Shared PERC 8 Card Not Seen In Device Managerp.32Critical Errors Or Disk Warning Messages Seen In The Windows Event Logp.32Shared PERC 8 Cards Fail To Functionp.33Physical disk issuesp.33Incorrect Number of Virtual Disks Displayed In Windows Disk Managerp.33Physical Disk In Failed Statep.33Unable to rebuild a fault tolerant virtual diskp.33Fatal Error Or Data Corruption Reportedp.34Physical Disk Displayed As Blocked By Management Applicationp.34Multiple Disks Become Inaccessiblep.34Rebuilding A Failed Physical Diskp.34Virtual Disk Fails During Rebuild Using A Global Hot Sparep.35Virtual Disk Fails During Rebuild Using A Dedicated Hot Sparep.35Physical disk takes a long time to rebuildp.35Controller cache issuesp.35SMART Errorsp.36SMART Error Detected On A Physical Disk In A Redundant Virtual Diskp.36SMART Error Detected On A Physical Disk In A Non-Redundant Virtual Diskp.37Auto Replacement Member Errorsp.37Source Disk Failsp.37Target Disk Failsp.37General Disk Failsp.37Hard-Drive Indicator Patternsp.38Getting helpp.39Contacting Dellp.39Locating your system Service Tagp.39Documentation feedbackp.39
Page 6 of the Dell UCPM-800 user manual — Configurations of the Shared PERC 8 card
Page 6 · click to enlarge
Page 6

1 About The Shared PERC 8 Card

The Dell Shared PowerEdge RAID Controller (PERC) 8 card installed on the Dell PowerEdge VRTX system supports Single Root Input Output Virtualization (SR-IOV). This feature allows multiple systems to share available hardware resources.

The PERC 8 card allows four server modules to access a local shared storage. Each server module's operating system loads a Virtual Function (VF) driver that allows the server module to communicate with the Shared PERC 8 firmware. The server module can then be mapped to either a single virtual disk or multiple virtual disks that are located on the shared storage. From a single server module, you can only access the virtual disks that are mapped to that server module.

Configurations of the Shared PERC 8 card

The PowerEdge VRTX system is available in two configurations of the Shared PERC 8 card:

Single Shared PERC 8 Card Configuration — In this configuration, the PowerEdge VRTX system is installed with a single Shared PERC 8 card. The default cache policy for virtual disks created in this configuration is write-back. In this mode, write completion information is returned to the host after the data is written to the Shared PERC 8 controller’s cache.

Fault Tolerant Shared PERC 8 Card Configuration — In this configuration, the PowerEdge VRTX system is installed with two Shared PERC 8 cards. The shared PERC cards are configured in an active-passive mode. Both the cards can access the storage subsystem. However, only the active controller will provide the data access. If one Shared PERC 8 card fails, the other Shared PERC 8 card takes control in a seamless transition.

Checkpoints are created for all background operations. After a failover, operations are restored from the last checkpoint. The default cache policy for virtual disks created in this configuration is write-back. In this mode, write completion information is returned to the host after the data is written to the peer shared PERC 8 controller’s cache.

Host data is also mirrored to the peer controller's cache to allow seamless operation in case of a primary card failure.

  • Multipath support must be enabled in the operating system for the Fault Tolerant Shared PERC 8 card configuration to function.
  • In the event of a controller failover, a Background Initialization (BGI) starts automatically on each virtual disk.
  • An ongoing full initialization does not restart in the event of a failover.
Page 7 of the Dell UCPM-800 user manual — Specifications of a Shared PERC 8 card
Page 7 · click to enlarge
Page 7
  • Currently, Linux drivers do not support the fault tolerance feature of the PowerEdge VRTX system. Host servers running Linux are only supported in single-controller configuration.

Specifications of a Shared PERC 8 card

The characteristics of a Shared PERC 8 card are as follows: Table 1. Shared PERC 8 card specifications

SpecificationDescription Supported drives Dell-qualified SAS hard drives and SAS solid state drives (SSDs). Mixing disks of different speeds (7,200 rpm, 10,000 rpm, or 15,000 rpm) and bandwidth (3 Gbps or 6 Gbps) while maintaining the same drive type (SAS) and technology (HDD or SSD) is supported. However, this may affect data transfer performance. NOTE: Mixing HDDs and SSDs within a virtual disk is not supported. SATA drives are not supported. RAID levels 0, 1, 5, 6, 10, 50, and 60 NOTE: Non-RAID drives are not supported. Virtual functions Four virtual functions to support up to four host servers Management application Dell Chassis Management Controller (CMC). NOTE: Option ROM (OP-ROM) is not supported. Booting from a shared storage is not supported. You can only boot from the storage located on the server module. Enclosure per port Not applicable Processor Dell Adapter SAS RAID-on-Chip, 8-Port with LSI 2208 Chipset Battery backup unit Yes Non-volatile cache Yes Cache memory 1 GB DDR3, 1333 MHz Cache policies Write Back, Forced Write-Back, Write Through, Adaptive ReadAhead, No Read-Ahead, and Read Ahead NOTE: Note that write-back caching in a dual controller configuration is not supported on the earlier versions of the Shared PERC 8 solution. NOTE: For the Shared PERC 8 card to support write-back feature, ensure that you download the updated firmware and driver version available at dell.com/support/home. NOTE: For more information, see the PowerEdge VRTX Storage Subsystem Compatibility Matrix at dell.com/ support/home.
Page 8 of the Dell UCPM-800 user manual — Specifications of a Shared PERC 8 card
Page 8 · click to enlarge
Page 8
SpecificationDescription Maximum number of spans per disk 8 group Maximum number of virtual disks per 16 disk group Maximum number of virtual disks 64 Dedicated and global hot spares Yes Hot swap devices supported Yes Hardware XOR engine Yes Virtual disk initialization; background, Yes full, and fast Consistency check Yes Disk roaming Yes FastPath Yes Virtual disk migration between two Yes Shared PERC 8 cards NOTE: The target Shared PERC 8 card firmware level must be either higher or equal to the source Shared PERC 8 card firmware level. Virtual disk migration from PERC No H310, H710, or H710P cards to a Shared PERC 8 card SMART detection Yes Patrol Read Yes Automatic replace member Yes SAS (HDD/SSD) hard drive Yes Physical disk power management IDLE-C for compliant HDDs only. No support for balanced, maximum, and customized power savings. SATA (HDD/SSD) hard drive No Manual replace member No Online capacity expansion No Cachecade No Local Key Management (LKM) No PCIe hot-plug of controller No
Page 9 of the Dell UCPM-800 user manual — Related Documentation
Page 9 · click to enlarge
Page 9
SpecificationDescription Multipath support Required for systems with Fault Tolerant Shared PERC 8 card configuration. NOTE: Multipath is not supported on systems running Linux operating system. Controller failover Available only for systems with Fault Tolerant Shared PERC 8 card configuration.

Supported Operating Systems

The Shared PERC 8 card supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2012
  • Microsoft Windows Server 2008 including Hyper-V virtualization
  • Microsoft Windows Server 2008 R2
  • Red Hat Enterprise Linux 6 Update 5
  • SUSE Enterprise Linux 11 SP3
  • VMware ESXi 5.1 UP1 and above
  • VMware ESXi 5.5, ESXi, 5.5 UP1 and above

Best Practices For Shared PERC 8

  • Always use the latest firmware and drivers from <a href="http://dell.com/support/drivers" rel="nofollow noopener" target="_blank">dell.com/support/drivers</a> .
  • Always keep a copy of your virtual disk configuration and server node mapping information. To document your virtual drive configuration and mapping information, perform the following steps:

a. Open CLI terminal and run the command racadm raid get vdisks –o. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.

b. Click Chassis Overview → Storage → Virtual Disks → Assign to view the virtual disk mapping by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.

c. Click Chassis Overview → Storage → Virtual Disks to get the virtual disk configuration information by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.

Related Documentation

  • The Dell PowerEdge VRTX Getting Started Guide shipped with your system provides an overview of system features, setting up your system, and technical specifications.
Page 10 of the Dell UCPM-800 user manual — Contacting Dell
Page 10 · click to enlarge
Page 10
  • The PowerEdge VRTX Storage Subsystem Compatibility Matrix provides information on the minimum driver and firmware requirements for the components of the Dell PowerEdge VRTX storage subsystem.
  • The setup placemat shipped with your system provides information on the initial system setup and configuration.
  • The server module Owner's Manual provides information about the server module features and describes how to troubleshoot the server module and install or replace the server module components. This document is available online at <a href="http://dell.com/poweredgemanuals" rel="nofollow noopener" target="_blank">dell.com/poweredgemanuals</a> .
  • The Updating Servers of M1000e Chassis and Using in VRTX Chassis provides information on updating M1000e server modules to be used in the VRTX chassis, using the Chassis Management Controller. This document is available online at <a href="http://dell.com/esmmanuals" rel="nofollow noopener" target="_blank">dell.com/esmmanuals</a> .
  • The rack documentation included with your rack solution describes how to install your system into a rack, if required.
  • The I/O module documentation at <a href="http://dell.com/poweredgemanuals" rel="nofollow noopener" target="_blank">dell.com/poweredgemanuals</a> describes the features of the I/O module installed in the VRTX enclosure.
  • The Dell Shared PowerEdge RAID Controller (PERC) 8 User's Guide provides information about deploying the Shared PERC 8 card and managing the storage subsystem. This document is available online at <a href="http://dell.com/storagecontrollermanuals" rel="nofollow noopener" target="_blank">dell.com/storagecontrollermanuals</a> .
  • The Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide provides information on installing, configuring and using the Chassis Management Controller (CMC). This document is available online at <a href="http://dell.com/esmmanuals" rel="nofollow noopener" target="_blank">dell.com/esmmanuals</a> .
  • The Dell PowerEdge VRTX Chassis Management Controller Firmware Event Message Reference Guide provides information on the error and event messages generated by the firmware or other agents that monitor system components. This document is available at <a href="http://dell.com/esmmanuals" rel="nofollow noopener" target="_blank">dell.com/esmmanuals</a> .
  • The CMC Online Help provides information and instructions for the current page on the CMC web interface. To access the Online Help , click Help on the CMC web interface.
  • The Integrated Dell Remote Access Controller (iDRAC) User’s Guide provides information about installation, configuration and maintenance of the iDRAC on managed systems. This document is available online at <a href="http://dell.com/esmmanuals" rel="nofollow noopener" target="_blank">dell.com/esmmanuals</a> .
  • Dell systems management application documentation provides information about installing and using the systems management software.
  • For the full name of an abbreviation or acronym used in this document, see the Glossary at <a href="http://dell.com/" rel="nofollow noopener" target="_blank">dell.com/</a> support/manuals .
  • Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.

Locating your system Service Tag

Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.

Contacting Dell

Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill,

Page 11 of the Dell UCPM-800 user manual — Documentation Feedback
Page 11 · click to enlarge
Page 11

or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:

2. Select your country from the drop-down menu on the bottom right corner of the page.
3. For customized support:

a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.

The support page that lists the various support categories is displayed.

4. For general support:

a. Select your product category. b. Select your product segment. c. Select your product.

The support page that lists the various support categories is displayed.

Documentation Feedback

If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill up the form, and click Submit to send your feedback.

Page 12 of the Dell UCPM-800 user manual — Virtual Disk Initialization
Page 12 · click to enlarge
Page 12

2 Shared PERC 8 Card Features

Some of the features of the Shared PERC 8 card are as follows:

  • Physical disk power management
  • Consistency checks
  • Virtual disk initialization
  • Disk roaming
  • FastPath
  • Virtual disk migration
  • Virtual disk cache policies
  • Fault tolerance
  • Patrol read
  • Multipath support

Physical Disk Power Management

Physical disk power management is a power saving feature of the Shared PERC 8 card. Idle-C feature, as defined by the T10 organization, is auto-enabled for physical disk power management. Physical disks that support Idle-C feature, spin at lower RPMs upon timer expiration when there is no I/O activity.

Consistency Checks

Consistency Check (CC) is a background operation that verifies and corrects the mirror or parity data for fault tolerant virtual disks. It is recommended that you periodically run a consistency check on virtual disks. You can manually start a CC in the Dell Chassis Management Controller (CMC).

Virtual Disk Initialization

You can initialize virtual disks as described in the following sections.

Page 13 of the Dell UCPM-800 user manual — Physical Disk Roaming
Page 13 · click to enlarge
Page 13

Background Initialization Of Virtual Disks

Both Consistency Check (CC) and Background Initialization (BGI) correct parity errors. However, CC reports data inconsistencies through an event notification, whereas BGI is an automatic process.

BGI does not run on RAID 0 virtual disks. You cannot disable BGI permanently. If you cancel BGI, it automatically restarts within five minutes. Unlike full or fast initialization of virtual disks, BGI does not clear data from the physical disks. CC or BGI typically causes some loss in performance until the operation completes.

Full Initialization Of Virtual Disks

During full initialization, the host is not able to access the virtual disk. You can start a full initialization on a virtual disk in the CMC.

In the event of a controller failover in systems with Fault Tolerant Shared PERC 8 card configuration, full initialization does not continue on the active controller. You must start full initialization again through CMC. For more information on virtual disk initialization, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/poweredgemanuals and the Dell Chassis Management Controller for Dell PowerEdge VRTX Online Help.

In the event of controller failover or system reboot during a full initialization, the operation terminates and a BGI begins on the virtual disk.

Fast Initialization Of Virtual Disks

A fast initialization on a virtual disk overwrites the first and last 8 MB of the virtual disk, clearing any boot records or partition information. The operation takes only 2-3 seconds to complete and is recommended when you are recreating virtual disks. You can perform a fast initialization in the CMC.

Physical Disk Roaming

Physical disk roaming is moving the physical disks from one backplane slot to another on the same controller. The controller automatically recognizes the relocated physical disks and logically places them in the virtual disks that are part of the disk group. You can perform disk roaming only when the system is turned off.

Page 14 of the Dell UCPM-800 user manual — Virtual Disk Migration
Page 14 · click to enlarge
Page 14

Using Physical Disk Roaming

Perform the following steps to use disk roaming:

1. Turn off the power to the system, physical disks, enclosures, and system components.
2. Disconnect power cables from the system.
3. Move the physical disks to the required positions on the backplane or the enclosure.
4. Perform a safety check. Make sure the physical disks are inserted properly.
5. Turn on the system.

The controller detects the RAID configuration from the configuration data on the physical disks.

FastPath

The Shared PERC 8 card supports FastPath feature, which improves application performance by delivering high I/O per second (IOPS).

Under specific conditions with FastPath, the I/O bypasses the controller cache and is committed directly to the physical disk from the host memory or directly from the physical disk. All simple non-spanned virtual disks configured with Write-Through write-cache policy and No Read-Ahead read-cache policy can utilize FastPath.

Workloads on SSD volumes provide the most performance improvement with FastPath.

The following conditions support FastPath:

  • Random workloads with small blocks.
  • I/O block sizes smaller than virtual disk’s stripe size.
  • Sequential read workloads on unspanned RAID volumes (RAID 0, RAID 1, RAID 5, and RAID 6).
  • Sequential read and write workloads on RAID 0 virtual disks.

The following conditions do not support FastPath

  • Virtual disks running background operations like rebuild, initialization, and so on.
  • Spanned RAID volumes like RAID 10, RAID 50, and RAID 60.

Virtual Disk Migration

The Shared PERC 8 card supports migration of virtual disks from one controller to another without taking the target controller offline. The controller can import RAID virtual disks in optimal, degraded, or partially degraded states.

Conditions that do not support virtual virtual disk migration:

  • Does not support migration of virtual disk that is in a failed state.
  • Does not support migration of virtual disk when the source system is turned on.

Conditions that support virtual virtual disk migration:

  • Supports migration of virtual disks from a similar Shared PERC 8 card.
Page 15 of the Dell UCPM-800 user manual — Virtual Disk Cache Policies
Page 15 · click to enlarge
Page 15
  • Does not support migration from any other PERC cards such as PERC H310, H700, H710, H800, and H810.
  • Supports migration of virtual disks from the Single Shared PERC 8 card configuration to the Fault Tolerant Shared PERC 8 card configuration, but does not support migration from a newer firmware version to an older firmware version system.
  • Supports migration of virtual disks from another system's Shared PERC 8 controller when the target system is either turned on or off

Migrating Virtual Disks If The Target System Is Turned Off

1. If installed, remove the front bezel (optional) from the PowerEdge VRTX enclosure.
2. Power down the server module using the operating system commands or the CMC, and ensure that the server module's power is off.
3. Turn off the chassis using CMC.
4. Move the appropriate physical disks from the source system to the target system with a similar Shared PERC 8 controller.
5. Turn on the target system.

The system discovers and automatically imports the detected foreign configuration.

Migrating Virtual Disks If The Target System Is Turned On

1. Turn off the source system.
2. Move the appropriate physical disks from the source system to the target system with a similar Shared PERC 8 card.
3. Access the Dell Chassis Management Controller (CMC) to import and clear the foreign configuration.

Virtual Disk Cache Policies

The following Virtual Disk Cache policies are supported on Shared PERC 8:

  • Virtual disk write cache policies
  • Virtual disk read cache policies
Page 16 of the Dell UCPM-800 user manual — Write-through
Page 16 · click to enlarge
Page 16

Virtual Disk Write Cache Policies

The write cache policy of a virtual disk determines how the controller handles writes to the virtual disk. Write-Back and Write-Through are the two write cache policies that can be set on virtual disks individually.

All RAID volumes are presented as Write-Through to the operating system independent of the actual write cache policy of the virtual disk. The Shared PERC 8 cards manage data in the cache independently of the operating system or any applications.

Write-Back

In Write-Back caching, the controller sends a data transfer completion signal to the host when the controller cache has received all the data in a transaction. The controller then writes the cached data to the storage device in the background.

The risk of using Write-Back cache is that the cached data can be lost if there is a power failure during or when the data is written to the storage device. This risk is mitigated by using a Non-Volatile Cache on the Shared PERC 8 card.

Conditions Under Which Write-Back Is Employed

Write-Back caching is the default caching mode for single and dual Shared PERC 8 card configurations. Write-Back caching can be configured under all conditions in which the battery is present and in good condition.

If a virtual disk is already created on the VRTX system with the firmware version that does not support write-back caching, then the default will remain as write-through. The virtual disk must be manually changed to write-back before it goes to write-back mode, even if the system has been updated to a write-back supported firmware version.

Conditions Under Which Forced Write-Back With No Battery Is Employed

Write-Back mode is available when you select Write-Back Force. When Write-Back Force mode is selected, the virtual disk is in Write-Back mode even if the battery is not present.

Write-through

In Write-Through caching, the controller sends a data transfer completion signal to the host system when the disk subsystem has received all the data in a transaction.

Page 17 of the Dell UCPM-800 user manual — Fault Tolerance
Page 17 · click to enlarge
Page 17

Conditions under which write-through is employed

Write-through caching is used under conditions in which the battery fails or is not present.

Virtual Disk Read Cache Policies

The read policy of a virtual disk determines how the controller handles reads to that virtual disk. The read policies are:

  • Read Ahead — Allows the controller to read sequentially ahead of the requested data and store the additional data in cache memory. This speeds up reads for sequential data, but there is little improvement when accessing random data.
  • No Read Ahead — Disables the Read-Ahead capability.
  • Adaptive Read Ahead — Begins using Read-Ahead if the two most recent disk accesses occurred in sequential sectors. If the read requests are random, the controller reverts to No Read Ahead mode.

Physical Disk Write Cache Policy

Management utilities provide the option to modify disk cache policies for physical disks associated with a virtual disk. The following options are available for the Shared PERC controller:

Enabled Enables physical disk cache for drives associated with the selected virtual disk.

Disabled Disables physical disk cache for drives associated with the selected virtual disk.

Default The default cache policy on the physical disk is used. See the physical disk documentation for details on the default setting.

Fault Tolerance

The fault tolerance features of Shared PERC 8 are as follows:

  • Support for Self Monitoring and Reporting Technology (SMART)
  • Support for Patrol Read
  • Physical disk failure detection
  • Physical disk rebuild using hot spares
  • Controller Cache Preservation
  • Battery and Non-Volatile Cache backup of controller cache to protect data
  • Detection of batteries with low charge after boot up

Option Description

Page 18 of the Dell UCPM-800 user manual — Patrol Read
Page 18 · click to enlarge
Page 18
  • Support for controller failover in systems with Fault Tolerant Shared PERC 8 card configuration.

The following sections describe some methods to achieve fault tolerance.

The SMART Feature

The SMART feature monitors certain physical aspects of all motors, heads, and physical disk electronics to help detect predictable physical disk failures. Data on SMART-compliant physical disks can be monitored to identify changes in values and determine whether the values are within threshold limits. Many mechanical and electrical failures display some degradation in performance before failure.

A SMART failure is also referred to as predicted failure. There are numerous factors that are predicted physical disk failures, such as a bearing failure, a broken read/write head, and changes in spin-up rate. In addition, there are factors related to read/write surface failure, such as seek error rate and excessive bad sectors.

Patrol Read

The Patrol Read feature is designed as a preventive measure to ensure physical disk health and data integrity. Patrol Read scans for and resolves potential problems on configured physical disks. The Dell Chassis Management Controller (CMC) can be used to start and control the features of Patrol Read.

The following is an overview of Patrol Read:

  • Patrol Read runs on all disks on the controller that are configured as part of a virtual disk, including hot spares.
  • Patrol Read does not run on physical disks that are not part of a virtual disk or are in Ready state.
  • Patrol Read adjusts the amount of controller resources dedicated to Patrol Read operations based on outstanding disk I/O. For example, if the system is busy processing I/O operation, then Patrol Read uses fewer resources to allow the I/O to take a higher priority.
  • Patrol Read does not run on disks involved in any of the following operations:

– Full or Background Initialization

– Consistency Check (CC)

For more information on Patrol Read, see the Dell Chassis Management Controller for PowerEdge VRTX Online Help.

– Rebuild · – Replace Member

Page 19 of the Dell UCPM-800 user manual — Shared PERC 8 Card Cache Preservation
Page 19 · click to enlarge
Page 19

Physical disk failure detection

Failed physical disks are detected and rebuilds automatically start to new disks that are inserted into the same slot. Automatic rebuilds can also occur with hot spares. If you have configured hot spares, the controllers automatically try to use them to rebuild failed physical disks.

Physical Disk Hot Swapping

Hot swapping is the manual replacement of a disk while the Shared PERC 8 card is online and performing the normal functions. The following requirements must be fulfilled before performing a hot swap of a physical disk:

  • The replacement disk must be of the same protocol and disk technology. For example, only a SAS hard drive can replace a SAS hard drive.
  • The replacement disk must be of equal or greater capacity than the one it is replacing.

Auto Replacement Of A Virtual Disk Member And Revertible Hot Spares

The automatic Replace Member functionality allows a previously commissioned hot spare to be reverted to a usable hot spare. When a disk failure occurs within a virtual disk, an assigned hot spare (dedicated or global) is commissioned and begins rebuilding until the virtual disk is optimal. After the failed physical disk is replaced (in the same slot) and the rebuild is complete, the Shared PERC 8 card automatically starts to copy data from the commissioned hot spare to the newly-inserted disk. After the data is copied, the new disk is a part of the virtual disk and the hot spare is reverted to a ready hot spare. This allows hot spares to remain in specific enclosure slots. While the Shared PERC 8 card is reverting the hot spare, the virtual disk remains optimal.

Shared PERC 8 Card Cache Preservation

The Shared PERC 8 card is capable of preserving its cache in the event of a system power outage or improper system shutdown. The Shared PERC 8 card is attached to a Battery Backup Unit (BBU) that provides backup power to transfer contents of the DRAM to the Non-Volatile Cache (NVC) during system power loss.

Cache Preservation With Non-Volatile Cache

The Cache Preservation With Non-Volatile Cache (NVC) module allows controller cache data to be stored indefinitely. If the controller has data in the cache memory during a power outage or improper system shutdown, a small amount of power from the battery is used to transfer cache data to a non- volatile flash storage where it remains until power is restored and the system is booted.

Page 20 of the Dell UCPM-800 user manual — The Controller Failover Feature
Page 20 · click to enlarge
Page 20

If a system power loss or improper system shutdown has occurred:

1. Ensure all online physical disks are still connected.
2. Restore the system power.
3. Boot the system.

Virtual disks are automatically imported and preserved cache (if any) will be flushed to the physical disks of appropriate virtual disks. If preserved cache is still present, there could be situations preventing the flushing of preserved cache data.

Battery Transparent Learn Cycle

A transparent learn cycle is a periodic operation that calculates the charge that is remaining in the battery to ensure there is sufficient energy. The operation runs automatically, and causes no impact to the system or Shared PERC 8 card performance. The Shared PERC 8 card automatically performs the Transparent Learn Cycle (TLC) on the battery to calibrate and gauge its charge capacity once every 90 days.

The time frame for completion of a learn cycle is a function of the battery charge capacity and the discharge and charge currents used. For Shared PERC 8 card, the expected time frame for completion of a learn cycle is approximately seven hours.

Conditions For Replacing The Battery

The Shared PERC 8 battery is marked Failed in the Battery Status in the CMC, when the state or health of the battery is declared bad. If battery is declared failed, then the firmware runs learn cycles in subsequent reboots until the battery is replaced. After the battery is replaced, the virtual disk then transitions to Write- Back mode.

The Controller Failover Feature

The dual-controller configuration of the VRTX system has two shared-PERC controllers configured in an active-passive mode. A single active controller monitors all the storage related processes. When the active controller stops functioning, the passive controller acts as a peer hot-spare, and takes over the functions of the active controller in a seamless manner. Although the transition is seamless with respect to the operating system, there may be some temporary performance impact in the course of the failover.

Recovering cache data · TLC Time Frame

Page 21 of the Dell UCPM-800 user manual — Multipath support in Linux
Page 21 · click to enlarge
Page 21

Multipath Support

Multipathing solutions use redundant physical path components such as adapters, cables, and switches to create logical paths between the server and the storage device. In the event that one or more of these components fails, multipathing logic uses an alternate path for I/O so that applications can still access their data.

In the Fault Tolerant Shared PERC 8 card configuration, the PowerEdge VRTX system has two Shared PERC 8 cards in an active-passive mode. In this configuration, each host server can access the same virtual disk through both cards. In the absence of a multipath driver, the operating system identifies the single disk as two identical disks. The multipath driver aggregates the two disks into a single disk with redundant access that is then presented to the operating system. The MPIO driver determines the path chosen for any I/O sent to the virtual disk. Any I/O directed to the passive card is internally redirected to the active card for completion.

Configuring Multipath Support In Windows

In Windows, multipath support is enabled by installing the MPIO driver. The Shared PERC 8 device must be added to the list of devices that are aggregated by MPIO after the device driver is installed. Perform the following steps to add the Shared PERC 8 card:

1. Open the MPIO control panel.
2. Click the Discover Multi-Paths tab.
3. Select DELL Shared PERC8 and click Add .

This is only a one time setup procedure. After the Shared PERC 8 device is added to the list of devices, the MPIO driver aggregates all instances of the same virtual disk into a single one. The recommended multipath policy for Windows is round-robin (with subset).

Configuring Multipath Support In VMWare

In VMWare, multipath support is automatically enabled using Native Multipathing (NMP) for all Shared PERC 8 cards in Dell versions of the ESXi operating systems.

Multipath support in Linux

Currently, Linux support is not offered by Dell on fault tolerant VRTX configurations.

Page 22 of the Dell UCPM-800 user manual — Replacing A Shared PERC 8 Card
Page 22 · click to enlarge
Page 22

3 Deploying The Shared PERC 8 Card

Follow the documentation in this section to remove or install a Shared PERC 8 card under different scenarios.

Installing A New Shared PERC 8 Card

For information on how to install a Shared PERC 8 card, see Installing The Shared PERC 8 Card.

For information on the post-installation tasks, see Post-Installation Tasks For Shared 8 Card.

Replacing A Shared PERC 8 Card

When replacing an existing Shared PERC8 card in the PowerEdge VRTX system, perform the steps in this chapter to ensure proper functionality of the shared storage after the replacement process is complete.

In the Single Shared PERC 8 card configuration, the shared PERC slot is labeled as INT_STORAGE_1 on the PowerEdge VRTX system board. In the Fault Tolerant Shared PERC 8 card configuration, the shared PERC slots are labeled as INT_STORAGE_1 and INT_STORAGE_2 on the PowerEdge VRTX system board. To locate the Shared PERC slots, see System Board Connectors in the Dell PowerEdge VRTX Enclosure Owner's Manual at dell.com/poweredgemanuals

Controller firmware package 23.8.10-0059 is the minimum firmware package version required for fault tolerant Shared PERC 8 configurations on PowerEdge VRTX.

For more information, see the storage subsystem compatibility matrix document at dell.com/support/ home

For information on removing and reinstalling system parts, see the VRTX Enclosure Owner's Manual of the system at dell.com/poweredgemanuals

Page 23 of the Dell UCPM-800 user manual — Removing The Shared PERC 8 Card
Page 23 · click to enlarge
Page 23

Prerequisites For Removing The Shared PERC 8 Card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the system.

Perform the following steps to enable recovery in the event the part replacement process fails:

1. Follow the operating system procedure to back up all data from the shared storage drives
2. Document your virtual drive configuration and mapping information by performing the following steps: a. Open CLI terminal and run the command racadm raid get vdisks –o. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location. b. Click Chassis Overview → Storage → Virtual Disks → Assign to view the virtual disk mapping by

the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location. c. Click Chassis Overview → Storage → Virtual Disks to get the virtual disk configuration

information by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.

3. Click Chassis Overview → Storage → Controllers to view the firmware version of the current Shared PERC 8 card. If your system has two Shared PERC 8 cards installed, the firmware version must be the same for both the cards.
4. Turn off the server modules using operating system commands or the CMC.
5. Turn off the enclosure, including any attached peripherals, and disconnect the enclosure from the electrical outlet and peripherals.
6. Remove the server modules and the shared storage hard drives from the PowerEdge VRTX system.
7. If applicable, rotate the system feet inward and lay the system on its side on a flat stable surface, with the cover release latch side on top.
8. Open the system.

Removing The Shared PERC 8 Card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the system.

Page 24 of the Dell UCPM-800 user manual — Prerequisites For Removing The Shared PERC 8 Card
Page 24 · click to enlarge
Page 24

To remove the Shared PERC 8 card:

1. Push down the two release levers at the edge of the Shared PERC 8 card to disengage the card from the storage-controller card holder.
2. Orient the card so that the other end of the card disengages from the storage-controller card holder on the system board.
Dell UCPM-800 — Prerequisites For Removing The Shared PERC 8 Card diagram (page 24)
Fig. 1 · Prerequisites For Removing The Shared PERC 8 Card

Figure 1. Removing and Installing the Shared PERC 8 Card

1. release lever (2) 2. storage-controller card holder
3. storage controller card 4. battery
5. heatsink 6. touch points (2)
7. storage-controller card connector on the system board
8. guide pins (2)
Page 25 of the Dell UCPM-800 user manual — Post-Installation Tasks For Shared PERC 8 Card
Page 25 · click to enlarge
Page 25

Installing The Shared PERC 8 Card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Align one end of the card with the card holder on the system board.
2. Lower the other end of the card into the storage-controller card holder on the system board.
3. Press the touch-points on the card and push the card down until it is fully seated.

When the card is fully seated, the release levers snap over the edge of the card.

4. Close the system.

Post-Installation Tasks For Shared PERC 8 Card

1. Turn on the PowerEdge VRTX system without hard drives and server modules inserted.

It may take up to 25 minutes for the PowerEdge VRTX storage subsystem to completely power on.

2. Log in to the CMC GUI.
3. Click Overview → Power → Control , and view the Power State to ensure that it is ON .
4. Click Chassis Overview → Storage → Controllers to view the firmware version of the replaced Shared PERC 8 card.

The firmware version must be same for both the cards.

5. If the system has two Shared PERC 8 cards, ensure that the Fault Tolerance Status is Healthy/ Normal . This is necessary to ensure that any new firmware has been initialized and is compatible before you reinsert the shared hard drives and modular servers.
6. Turn off the PowerEdge VRTX system.
7. Insert the shared storage hard drives that you had removed earlier. Insert the shared hard drives in the original slots.
8. Turn on the PowerEdge VRTX system.
9. Check the Virtual Disk Layout and the Virtual Disk Assignments in the CMC GUI. If the virtual disks are not imported, not present, or the virtual disk assignments are not present or are incorrect, contact Dell Technical Support.
10. Turn off the PowerEdge VRTX system.
11. Insert the server modules that you had removed earlier. Insert the server modules in the original slots.
12. Turn on the PowerEdge VRTX system.
13. Turn on the server modules.
Page 26 of the Dell UCPM-800 user manual — Updating firmware
Page 26 · click to enlarge
Page 26

Firmware installation or update

The VRTX storage subsystem comprises of Shared PERC firmware, drivers, Chassis Infrastructure firmware and the CMC. When updating any of these components, make sure that all the component versions are at a compatible baseline.

Updating firmware

Before you begin, download the windows update package for the firmware.

1. Log in to the VRTX CMC.
2. Make sure that you turn off all the server modules.
3. Navigate to Storage and click the Update tab.
4. Browse to the location where you downloaded the file and select the new file.
5. Click Upload .
6. After the file transfer, select the check box next to the release version, and click Update .
Page 27 of the Dell UCPM-800 user manual — 4 Driver Installation
Page 27 · click to enlarge
Page 27

4 Driver Installation

The Dell Shared PowerEdge RAID Controller (PERC) 8 card requires software drivers to operate with the supported operating systems.

This chapter contains the procedures for installing the drivers for the Shared PERC 8 card.

Downloading Drivers and Firmware For Shared PERC 8 From The Dell Support Website For All Operating Systems

2. In the Product Selection section, enter the service tag of your system in the Service Tag or Express Service Code field.

NOTE: To download the latest firmware and drivers for a server module (for example Dell PowerEdge M520, M620, and M820), enter the service tag or the model number of the server module. To download the latest firmware and driver for components inside the PowerEdge VRTX chassis (for example Shared PERC 8 firmware and driver), enter the service tag or the model number of the PowerEdge VRTX chassis.

3. Select the Operating System , Category , Release Date , and Importance from the respective dropdown lists.

The drivers that are applicable to your selection are displayed.

4. Download the drivers that you require to a diskette drive, USB drive, CD, or DVD.
5. During the operating system installation, use the media that you created with the Load Driver option to load mass storage drivers. For more information on reinstalling the operating system, see the operating system document at dell.com/operatingsystemmanuals.

Downloading Drivers From The Dell Systems Service And Diagnostic Tools Media For Windows

To download drivers from the Dell Systems Service and Diagnostic Tools media:

1. Insert the Dell Systems Service and Diagnostics Tools media in a system.

The Welcome to Dell Service and Diagnostic Utilities screen is displayed.

2. Select your system model and operating system.
Page 28 of the Dell UCPM-800 user manual — Installing Or Updating Windows Drivers For Shared PERC 8
Page 28 · click to enlarge
Page 28

For the list of supported operating systems, see Supported Operating Systems.

3. Click Continue .
4. From the list of drivers displayed, select the driver you require.
5. Select the self-extracting zip file and click Run .
6. Copy the driver to a diskette drive, CD, DVD, or USB drive.

Repeat this step for all the drivers you require.

7. During the operating system installation, use the media that you created with the Load Driver option to load mass storage drivers.

For more information on reinstalling the operating system, see the relevant document at dell.com/ support/manuals.

Installing Or Updating Windows Drivers For Shared PERC 8

This procedure is applicable for updating existing Windows Server 2008 R2 or Windows Server 2012/2012 R2 drivers.

1. Insert the media (CD, DVD, or USB drive) containing the driver.
2. Select Start → Settings → Control Panel → System.

The System Properties screen is displayed.

3. Click on the Hardware tab.
4. Click Device Manager .

The Device Manager screen is displayed.

5. Expand SCSI and RAID Controllers by double-clicking the entry or by clicking on the plus symbol next to SCSI and RAID Controller .
6. Double-click the RAID controller for which you want to update the driver.
7. Click the Driver tab and click Update Driver .

The screen to update the device driver wizard is displayed.

8. Select Install from a list or specific location .
9. Click Next .
10. Follow the steps in the wizard and browse to the location of the driver files.
11. Select the INF file from the driver media (CD, DVD, or other media).
12. Click Next and continue with the installation steps in the wizard.
13. Click Finish to exit the wizard and reboot the system for the changes to take place.
Page 29 of the Dell UCPM-800 user manual — Installing Or Updating VMware Drivers For Shared PERC 8
Page 29 · click to enlarge
Page 29

Installing Or Updating Linux Drivers For Shared PERC 8

Use the procedures in this section to update the driver for Red Hat Enterprise Linux 6 Update 5 and SUSE Enterprise Linux 11 SP3. To ensure that you have the current version of the driver, download the updated Linux driver from dell.com/support

Installing Or Updating The Driver Package On RHEL Using KMOD Support

Perform the following steps to install the RPM package with KMOD support:

1. Uncompress the gzipped tarball driver release package.
2. Install the driver package using the command rpm –ihv kmod-megaraid_ sas- .x86_64.rpm
3. Reboot the system for the updated driver to take effect.
4. Verify that the driver has been loaded using the command modinfo megaraid_sas
5. View the list of controllers installed on your system using the command lspci | grep IOV

Installing Or Updating The Driver Package On SLES Using KMP Support

Perform the following steps to install the RPM package with KMP support:

1. Uncompress the gzipped tarball driver release package.
2. Install the driver package using the command rpm –ihv kmod-megaraid_ sas- .x86_64.rpm
3. Reboot the system for the updated driver to take effect.
4. Verify that the driver is loaded using the command modinfo megaraid_sas
5. View the list of controllers installed on your system using the command lspci | grep IOV

Installing Or Updating VMware Drivers For Shared PERC 8

For information on how to install drivers on VMware ESXi 5.1 and 5.5, see kb.vmware.com/kb/2005205 For information on VMware ESXi drivers, see the VMware ESXi documentation at dell.com/ virtualizationsolutions.

Page 30 of the Dell UCPM-800 user manual — 5 Management Applications For Shared PERC 8 Card
Page 30 · click to enlarge
Page 30

5 Management Applications For Shared PERC 8 Card

The Dell Chassis Management Controller (CMC) enables you to:

  • Configure the shared RAID system
  • Create and manage multiple disk groups
  • Control and monitor multiple RAID systems
  • Provide online maintenance through a web interface or Command Line Interface (CLI)

For more information on the CMC web interface or CLI commands available for Shared PERC 8, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/esmmanuals

Page 31 of the Dell UCPM-800 user manual — Shared PERC 8 Card Boots Into Safe Mode
Page 31 · click to enlarge
Page 31

6 Troubleshooting

To get help with your Dell Shared PowerEdge RAID Controller Shared (PERC) 8 card, you can contact your Dell Technical Service representative or see dell.com/contactdell

Performance variations between write-back and writethrough cache modes

Performance is highly variable across configurations, drive type, applications and IO workloads. The write performance of write-through mode is typically lower than that of write-back mode. Some configurations and workloads exhibit significant performance deltas.

Evaluate your needs for maximum I/O performance (a single Shared PERC 8 configuration) versus maximum data protection (a Fault Tolerant Shared PERC 8 configuration).

Shared PERC 8 Card Boots Into Safe Mode

In the event of some failure conditions encountered at boot, Shared PERC 8 boots with restricted capability in safe mode without user intervention. In such a condition Shared PERC 8 reports all configured disk drives as Foreign to the management application. The Dell Chassis Management Controller (CMC) displays events generated by the Shared PERC 8 card indicating the reason for booting into safe mode. The following table details the conditions and the corresponding event notifications that are reported to the CMC. Table 2. Conditions and the Corresponding Event Notifications Reported to the CMC

Category Event Reported To the CMC Description of the Failure

Controller cache pinned for missing or offline VDs: %s

The Shared PERC 8 card preserves dirty cache for a virtual disk that transitioned to offline or was deleted due to missing physical disks.

You can restore the preserved cache to the virtual disk once the original drives are re- inserted and the foreign configuration is imported.

Controller booted to safe mode due to critical errors Critical Error during boot - On-board expander FW or mfg image is corrupted - reflash image

This issue occurs if expanders are not detected.

Reseat and cable the expanders.

Corrective Action · Pinned Cache · SAS Discovery

Page 32 of the Dell UCPM-800 user manual — Critical Errors Or Disk Warning Messages Seen In The Windows Event Log
Page 32 · click to enlarge
Page 32

Category Event Reported To the CMC Description of the Failure

Critical Error during boot - NVDATA image is invalid - reflash NVDATA image

The NVData image is invalid.

Contact Dell Technical Support.

Degraded State Of Virtual Disks

A redundant virtual disk is in a degraded state when one or more physical disks have failed or are inaccessible. For example, if a RAID 1 virtual disk consists of two physical disks and one of them fails or becomes inaccessible, the virtual disk becomes degraded.

To recover a virtual disk from a degraded state, you must replace the failed physical disk and rebuild it. After the rebuilding process is complete, the virtual disk state changes from degraded to optimal.

General Issues

Shared PERC 8 Card Has Yellow Exclamation Mark In Device Manager

Issue: The device is displayed in Device Manager but has a yellow exclamation mark (!).

Corrective Action:

Reinstall the driver. For more information on reinstalling drivers, see Driver Installation. If reinstalling the driver does not resolve the yellow exclamation mark, perform a shutdown of all server modules and power cycle the chassis.

Shared PERC 8 Card Not Seen In Device Manager

Issue: The device does not appear in the Device Manager.

Corrective Action:

In the Dell Chassis Management Controller (CMC) application, verify if the Shared PERC 8 is correctly mapped to the server module. For more information on assigning virtual adapters to server slots, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/poweredgemanuals

If the Virtual Adapter to Server Slot mapping is correct and the device still does not appear in the Device Manager, turn off the system and reseat the Shared PERC 8 card.

Critical Errors Or Disk Warning Messages Seen In The Windows Event Log

Issue: Error messages such as Critical Event11, PERCSAS2The driver detected a controller error on \Device\RaidPort...

Corrective Action · or,

Page 33 of the Dell UCPM-800 user manual — Unable to rebuild a fault tolerant virtual disk
Page 33 · click to enlarge
Page 33

The IO operation at logical block address xxxxxx for Disk x was retried

referring to the PercSAS2 driver is seen in the Windows Event log .

Corrective Action:

These error messages may be triggered under some non-critical cases. See the system status and the CMC logs to identify any persistent failures.

Shared PERC 8 Cards Fail To Function

Issue: Shared PERC 8 cards fail to function in systems with the Fault Tolerant Shared PERC 8 card configuration.

Corrective Action:

This issue may occur if the Shared PERC 8 card property settings between the two Shared PERC 8 cards is not compatible. Make sure that the firmware packages are identical for both the Shared PERC 8 cards.

Physical disk issues

Incorrect Number of Virtual Disks Displayed In Windows Disk Manager

Issue: The number of disks displayed in Windows Disk Manager is more than the actual number of virtual disks assigned to the server.

Corrective Action:

This issue occurs if the MPIO feature is not installed in systems with the Fault Tolerant Shared PERC 8 card configuration. Install MPIO services from the list of features that can be installed on the server. For instructions on how to install MPIO, see Installing and Configuring MPIO at technet.microsoft.com.

Physical Disk In Failed State

Issue: One of the physical disks in the disk array is in the failed state.

Corrective Action:

Update the Shared PERC 8 cards to the latest firmware available on dell.com/ support. Replace the physical disk with a working one which is compatible with the old physical disk and is of equal or greater capacity.

Unable to rebuild a fault tolerant virtual disk

Issue: Cannot rebuild a fault tolerant virtual disk. For more information, see the alert log for virtual disks.

Corrective Action:

The replacement disk is too small or not compatible with the virtual disk. Replace the failed disk with a compatible good physical disk with equal or greater capacity.

Page 34 of the Dell UCPM-800 user manual — Rebuilding A Failed Physical Disk
Page 34 · click to enlarge
Page 34

Fatal Error Or Data Corruption Reported

Issue: Fatal error(s) or data corruption(s) is reported when accessing virtual disks.

Corrective Action:

Contact Dell Technical Support.

Physical Disk Displayed As Blocked By Management Application

Issue: One or more physical disks are displayed as Blocked and cannot be configured.

Corrective Action:

Ensure the physical disk is supported by SCSI-3 Persistent Reservation (PR). Update the physical disk and Shared PERC 8 to the latest firmware available on dell.com/ support.

Multiple Disks Become Inaccessible

Issue: Multiple disks become simultaneously inaccessible.

Corrective Action:

Multiple physical disk errors in a single array indicate a failure in cabling or connection and can involve loss of data. Perform the following steps to recover the virtual disk:

1. Turn off the system, check the cable connections, and reseat the physical disks.
2. Ensure that all the disks are present in the enclosure.
3. Turn on the system and enter the Chassis Management Controller (CMC).
4. Use the CMC to import the foreign configuration that is detected or clear the foreign configuration.

If the virtual disk is redundant and transitioned to Degraded state before going Offline, a rebuild operation starts automatically after the configuration is imported. If the virtual disk has gone directly to the Offline state due to a cable pull or power loss situation, the virtual disk is imported in its Optimal state without a rebuild occurring.

Rebuilding A Failed Physical Disk

Issue: Rebuilding a physical disk after one of them is in a failed state.

Corrective Action:

If you have configured hot spares, the Shared PERC 8 card automatically tries to rebuild a physical disk that is in a failed state. The automatic rebuild is not available if there is no hot spare with enough capacity to rebuild the failed physical disk. You

Page 35 of the Dell UCPM-800 user manual — Controller cache issues
Page 35 · click to enlarge
Page 35

must make sure a physical disk with enough storage in the subsystem is set as a hot spare for rebuilding the physical disk.

Virtual Disk Fails During Rebuild Using A Global Hot Spare

Issue: A virtual disk fails during rebuild while using a global hot spare. The global hot spare reverts to Hotspare state and the virtual disk is in Failed state.

Corrective Action:

Check whether the original virtual disk has failed or has been removed.

Virtual Disk Fails During Rebuild Using A Dedicated Hot Spare

Issue: A virtual disk fails during rebuild while using a dedicated hot spare. The dedicated hot spare goes to Ready state and the virtual disk goes to Failed state.

Description: Check whether the original virtual disk has failed or has been removed.

Physical disk takes a long time to rebuild

Issue: A physical disk is taking longer than expected to rebuild.

Description: A physical disk takes longer to rebuild when under high stress. For example, there is one rebuild I/O operation for every five host I/O operations. You cannot add a second virtual disk to a disk group while the virtual disk in that disk group is undergoing a rebuild. The firmware does not allow you to create a virtual disk using the free space available in a disk group if a physical disk in a virtual disk group is undergoing a rebuild operation.

Controller cache issues

For certain conditions virtual drives will be either not configured to write-back caching or if configured, it will transition to write-through caching. The status of write-back caching can be viewed through CMC storage logs.

The following table details the conditions and the corrective actions.

Table 3. Conditions and the corrective actions

During the VRTX power on with no failing conditions, the virtual drive temporarily transitions to write-through as part of the Shared PERC 8 firmware initialization. After the system power on, the virtual drive transitions back to write-back.

There is no intervention required.

Perform the following:

During VRTX power on or reset, unresolved pinned cache is present.

  • Insert the drives that caused the virtual drive to go offline, that resulted in the cache being pinned to recover the virtual drive. OR
  • Clear the pinned cache through CMC.

Conditions Actions

Page 36 of the Dell UCPM-800 user manual — SMART Error Detected On A Physical Disk In A Redundant Virtual Disk
Page 36 · click to enlarge
Page 36

During a Shared PERC firmware flash, virtual drive transitions to write-through until chassis is recycled.

Allow the chassis reset to complete after the firmware flash.

Virtual drives permanently transition to write- through when Hardware failure occurs.

If hardware failure occurs, contact Dell technical support. For more information, see the Getting help.

In the event of a firmware mismatch, in the dual fault tolerant Shared PERC 8 configurations, if one controller has write-through capability and the other does not, virtual drives on the controller with write-through capability reverts to write-through.

Update the firmware such that both cards are running the latest supported versions available.

SMART Errors

Self Monitoring and Reporting Technology (SMART) monitors the internal performance of all motors, heads, and physical disk electronics and detects predictable physical disk failures.

SMART Error Detected On A Physical Disk In A Redundant Virtual Disk

Issue: A SMART error is detected on a physical disk in a redundant virtual disk.

Corrective Action:

Perform the following steps:

1. Back up your data.
2. Physically remove the physical disk that detected the SMART error.
3. Replace the disk with a new physical disk of equal or higher capacity.
4. Perform the Auto Replacement of a Virtual Disk operation.

Conditions Actions

Page 37 of the Dell UCPM-800 user manual — General Disk Fails
Page 37 · click to enlarge
Page 37

SMART Error Detected On A Physical Disk In A Non-Redundant Virtual Disk

Issue: A SMART error is detected on a physical disk in a non-redundant virtual disk.

Corrective Action:

Perform the following steps:

1. Back up your data.
2. Physically remove the physical disk that detected the SMART error.
3. Replace the affected physical disk with a new physical disk of equal or higher capacity.
4. Delete the failed virtual disk and recreate the virtual disk with the same members.
5. Restore from the backup.

Auto Replacement Member Errors

Source Disk Fails

Issue: The source disk fails during the Auto Replacement Member operation.

Description: If the source data is available from other disks in the virtual disk, the rebuild begins automatically on the target disk, using the data from the other disks.

Target Disk Fails

Issue: The target disk fails.

Description: If the target disk fails, the Auto Replacement Member operation is terminated.

General Disk Fails

Issue: A general disk fails.

Description: If the target disk fails and the Auto Replacement Member operation terminates but the source data is still available, then the Auto Replacement Member operation continues as Auto Replacement Member.

Page 38 of the Dell UCPM-800 user manual — Hard-Drive Indicator Patterns
Page 38 · click to enlarge
Page 38

Hard-Drive Indicator Patterns

Dell UCPM-800 — Hard-Drive Indicator Patterns diagram (page 38)
Fig. 2 · Hard-Drive Indicator Patterns

Figure 2. Hard-Drive Indicators

1. hard-drive activity indicator (green) 2. hard-drive status indicator (green and amber)

Drive-Status Indicator Pattern Condition

Blinks green two times per second Identifying drive or preparing for removal

Off Drive ready for insertion or removal

Blinks green, amber, and off Predicted drive failure

Blinks amber four times per second Drive failed

Blinks green slowly Drive rebuilding

Steady green Drive online

Blinks green three seconds, amber three seconds, and off six seconds

Rebuild aborted

Page 39 of the Dell UCPM-800 user manual — Documentation feedback
Page 39 · click to enlarge
Page 39

7 Getting help

Contacting Dell

Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:

2. Select your country from the drop-down menu on the bottom right corner of the page.
3. For customized support:

a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.

The support page that lists the various support categories is displayed.

4. For general support:

a. Select your product category. b. Select your product segment. c. Select your product.

The support page that lists the various support categories is displayed.

Locating your system Service Tag

Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.

Documentation feedback

If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit to send your feedback.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dell UCPM-800

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dell UCPM-800

Be the first to ask — other owners or our team will answer.

Original document

Dell UCPM-800 manual PDF

39 pages·1.1 MB·Home Theater Server·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…