Dell Shared PowerEdge RAID Controller (PERC) 8 For Dell PowerEdge VRTX Systems User’s Guide

Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A03
2014 - 11




The Dell Shared PowerEdge RAID Controller (PERC) 8 card installed on the Dell PowerEdge VRTX system supports Single Root Input Output Virtualization (SR-IOV). This feature allows multiple systems to share available hardware resources.
The PERC 8 card allows four server modules to access a local shared storage. Each server module's operating system loads a Virtual Function (VF) driver that allows the server module to communicate with the Shared PERC 8 firmware. The server module can then be mapped to either a single virtual disk or multiple virtual disks that are located on the shared storage. From a single server module, you can only access the virtual disks that are mapped to that server module.
The PowerEdge VRTX system is available in two configurations of the Shared PERC 8 card:
Single Shared PERC 8 Card Configuration — In this configuration, the PowerEdge VRTX system is installed with a single Shared PERC 8 card. The default cache policy for virtual disks created in this configuration is write-back. In this mode, write completion information is returned to the host after the data is written to the Shared PERC 8 controller’s cache.
Fault Tolerant Shared PERC 8 Card Configuration — In this configuration, the PowerEdge VRTX system is installed with two Shared PERC 8 cards. The shared PERC cards are configured in an active-passive mode. Both the cards can access the storage subsystem. However, only the active controller will provide the data access. If one Shared PERC 8 card fails, the other Shared PERC 8 card takes control in a seamless transition.
Checkpoints are created for all background operations. After a failover, operations are restored from the last checkpoint. The default cache policy for virtual disks created in this configuration is write-back. In this mode, write completion information is returned to the host after the data is written to the peer shared PERC 8 controller’s cache.
Host data is also mirrored to the peer controller's cache to allow seamless operation in case of a primary card failure.

The characteristics of a Shared PERC 8 card are as follows: Table 1. Shared PERC 8 card specifications


The Shared PERC 8 card supports the following operating systems:
a. Open CLI terminal and run the command racadm raid get vdisks –o. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
b. Click Chassis Overview → Storage → Virtual Disks → Assign to view the virtual disk mapping by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
c. Click Chassis Overview → Storage → Virtual Disks to get the virtual disk configuration information by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.

Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.
Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill,

or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:
a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.
The support page that lists the various support categories is displayed.
a. Select your product category. b. Select your product segment. c. Select your product.
The support page that lists the various support categories is displayed.
If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill up the form, and click Submit to send your feedback.

Some of the features of the Shared PERC 8 card are as follows:
Physical disk power management is a power saving feature of the Shared PERC 8 card. Idle-C feature, as defined by the T10 organization, is auto-enabled for physical disk power management. Physical disks that support Idle-C feature, spin at lower RPMs upon timer expiration when there is no I/O activity.
Consistency Check (CC) is a background operation that verifies and corrects the mirror or parity data for fault tolerant virtual disks. It is recommended that you periodically run a consistency check on virtual disks. You can manually start a CC in the Dell Chassis Management Controller (CMC).
You can initialize virtual disks as described in the following sections.

Both Consistency Check (CC) and Background Initialization (BGI) correct parity errors. However, CC reports data inconsistencies through an event notification, whereas BGI is an automatic process.
BGI does not run on RAID 0 virtual disks. You cannot disable BGI permanently. If you cancel BGI, it automatically restarts within five minutes. Unlike full or fast initialization of virtual disks, BGI does not clear data from the physical disks. CC or BGI typically causes some loss in performance until the operation completes.
During full initialization, the host is not able to access the virtual disk. You can start a full initialization on a virtual disk in the CMC.
In the event of a controller failover in systems with Fault Tolerant Shared PERC 8 card configuration, full initialization does not continue on the active controller. You must start full initialization again through CMC. For more information on virtual disk initialization, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/poweredgemanuals and the Dell Chassis Management Controller for Dell PowerEdge VRTX Online Help.
In the event of controller failover or system reboot during a full initialization, the operation terminates and a BGI begins on the virtual disk.
A fast initialization on a virtual disk overwrites the first and last 8 MB of the virtual disk, clearing any boot records or partition information. The operation takes only 2-3 seconds to complete and is recommended when you are recreating virtual disks. You can perform a fast initialization in the CMC.
Physical disk roaming is moving the physical disks from one backplane slot to another on the same controller. The controller automatically recognizes the relocated physical disks and logically places them in the virtual disks that are part of the disk group. You can perform disk roaming only when the system is turned off.

Perform the following steps to use disk roaming:
The controller detects the RAID configuration from the configuration data on the physical disks.
The Shared PERC 8 card supports FastPath feature, which improves application performance by delivering high I/O per second (IOPS).
Under specific conditions with FastPath, the I/O bypasses the controller cache and is committed directly to the physical disk from the host memory or directly from the physical disk. All simple non-spanned virtual disks configured with Write-Through write-cache policy and No Read-Ahead read-cache policy can utilize FastPath.
Workloads on SSD volumes provide the most performance improvement with FastPath.
The following conditions support FastPath:
The following conditions do not support FastPath
The Shared PERC 8 card supports migration of virtual disks from one controller to another without taking the target controller offline. The controller can import RAID virtual disks in optimal, degraded, or partially degraded states.
Conditions that do not support virtual virtual disk migration:
Conditions that support virtual virtual disk migration:

The system discovers and automatically imports the detected foreign configuration.
The following Virtual Disk Cache policies are supported on Shared PERC 8:

The write cache policy of a virtual disk determines how the controller handles writes to the virtual disk. Write-Back and Write-Through are the two write cache policies that can be set on virtual disks individually.
All RAID volumes are presented as Write-Through to the operating system independent of the actual write cache policy of the virtual disk. The Shared PERC 8 cards manage data in the cache independently of the operating system or any applications.
In Write-Back caching, the controller sends a data transfer completion signal to the host when the controller cache has received all the data in a transaction. The controller then writes the cached data to the storage device in the background.
The risk of using Write-Back cache is that the cached data can be lost if there is a power failure during or when the data is written to the storage device. This risk is mitigated by using a Non-Volatile Cache on the Shared PERC 8 card.
Write-Back caching is the default caching mode for single and dual Shared PERC 8 card configurations. Write-Back caching can be configured under all conditions in which the battery is present and in good condition.
If a virtual disk is already created on the VRTX system with the firmware version that does not support write-back caching, then the default will remain as write-through. The virtual disk must be manually changed to write-back before it goes to write-back mode, even if the system has been updated to a write-back supported firmware version.
Write-Back mode is available when you select Write-Back Force. When Write-Back Force mode is selected, the virtual disk is in Write-Back mode even if the battery is not present.
In Write-Through caching, the controller sends a data transfer completion signal to the host system when the disk subsystem has received all the data in a transaction.

Write-through caching is used under conditions in which the battery fails or is not present.
The read policy of a virtual disk determines how the controller handles reads to that virtual disk. The read policies are:
Management utilities provide the option to modify disk cache policies for physical disks associated with a virtual disk. The following options are available for the Shared PERC controller:
Enabled Enables physical disk cache for drives associated with the selected virtual disk.
Disabled Disables physical disk cache for drives associated with the selected virtual disk.
Default The default cache policy on the physical disk is used. See the physical disk documentation for details on the default setting.
The fault tolerance features of Shared PERC 8 are as follows:
Option Description

The following sections describe some methods to achieve fault tolerance.
The SMART feature monitors certain physical aspects of all motors, heads, and physical disk electronics to help detect predictable physical disk failures. Data on SMART-compliant physical disks can be monitored to identify changes in values and determine whether the values are within threshold limits. Many mechanical and electrical failures display some degradation in performance before failure.
A SMART failure is also referred to as predicted failure. There are numerous factors that are predicted physical disk failures, such as a bearing failure, a broken read/write head, and changes in spin-up rate. In addition, there are factors related to read/write surface failure, such as seek error rate and excessive bad sectors.
The Patrol Read feature is designed as a preventive measure to ensure physical disk health and data integrity. Patrol Read scans for and resolves potential problems on configured physical disks. The Dell Chassis Management Controller (CMC) can be used to start and control the features of Patrol Read.
The following is an overview of Patrol Read:
– Full or Background Initialization
– Consistency Check (CC)
For more information on Patrol Read, see the Dell Chassis Management Controller for PowerEdge VRTX Online Help.
– Rebuild · – Replace Member

Failed physical disks are detected and rebuilds automatically start to new disks that are inserted into the same slot. Automatic rebuilds can also occur with hot spares. If you have configured hot spares, the controllers automatically try to use them to rebuild failed physical disks.
Hot swapping is the manual replacement of a disk while the Shared PERC 8 card is online and performing the normal functions. The following requirements must be fulfilled before performing a hot swap of a physical disk:
The automatic Replace Member functionality allows a previously commissioned hot spare to be reverted to a usable hot spare. When a disk failure occurs within a virtual disk, an assigned hot spare (dedicated or global) is commissioned and begins rebuilding until the virtual disk is optimal. After the failed physical disk is replaced (in the same slot) and the rebuild is complete, the Shared PERC 8 card automatically starts to copy data from the commissioned hot spare to the newly-inserted disk. After the data is copied, the new disk is a part of the virtual disk and the hot spare is reverted to a ready hot spare. This allows hot spares to remain in specific enclosure slots. While the Shared PERC 8 card is reverting the hot spare, the virtual disk remains optimal.
The Shared PERC 8 card is capable of preserving its cache in the event of a system power outage or improper system shutdown. The Shared PERC 8 card is attached to a Battery Backup Unit (BBU) that provides backup power to transfer contents of the DRAM to the Non-Volatile Cache (NVC) during system power loss.
Cache Preservation With Non-Volatile Cache
The Cache Preservation With Non-Volatile Cache (NVC) module allows controller cache data to be stored indefinitely. If the controller has data in the cache memory during a power outage or improper system shutdown, a small amount of power from the battery is used to transfer cache data to a non- volatile flash storage where it remains until power is restored and the system is booted.

If a system power loss or improper system shutdown has occurred:
Virtual disks are automatically imported and preserved cache (if any) will be flushed to the physical disks of appropriate virtual disks. If preserved cache is still present, there could be situations preventing the flushing of preserved cache data.
A transparent learn cycle is a periodic operation that calculates the charge that is remaining in the battery to ensure there is sufficient energy. The operation runs automatically, and causes no impact to the system or Shared PERC 8 card performance. The Shared PERC 8 card automatically performs the Transparent Learn Cycle (TLC) on the battery to calibrate and gauge its charge capacity once every 90 days.
The time frame for completion of a learn cycle is a function of the battery charge capacity and the discharge and charge currents used. For Shared PERC 8 card, the expected time frame for completion of a learn cycle is approximately seven hours.
Conditions For Replacing The Battery
The Shared PERC 8 battery is marked Failed in the Battery Status in the CMC, when the state or health of the battery is declared bad. If battery is declared failed, then the firmware runs learn cycles in subsequent reboots until the battery is replaced. After the battery is replaced, the virtual disk then transitions to Write- Back mode.
The dual-controller configuration of the VRTX system has two shared-PERC controllers configured in an active-passive mode. A single active controller monitors all the storage related processes. When the active controller stops functioning, the passive controller acts as a peer hot-spare, and takes over the functions of the active controller in a seamless manner. Although the transition is seamless with respect to the operating system, there may be some temporary performance impact in the course of the failover.
Recovering cache data · TLC Time Frame

Multipathing solutions use redundant physical path components such as adapters, cables, and switches to create logical paths between the server and the storage device. In the event that one or more of these components fails, multipathing logic uses an alternate path for I/O so that applications can still access their data.
In the Fault Tolerant Shared PERC 8 card configuration, the PowerEdge VRTX system has two Shared PERC 8 cards in an active-passive mode. In this configuration, each host server can access the same virtual disk through both cards. In the absence of a multipath driver, the operating system identifies the single disk as two identical disks. The multipath driver aggregates the two disks into a single disk with redundant access that is then presented to the operating system. The MPIO driver determines the path chosen for any I/O sent to the virtual disk. Any I/O directed to the passive card is internally redirected to the active card for completion.
In Windows, multipath support is enabled by installing the MPIO driver. The Shared PERC 8 device must be added to the list of devices that are aggregated by MPIO after the device driver is installed. Perform the following steps to add the Shared PERC 8 card:
This is only a one time setup procedure. After the Shared PERC 8 device is added to the list of devices, the MPIO driver aggregates all instances of the same virtual disk into a single one. The recommended multipath policy for Windows is round-robin (with subset).
In VMWare, multipath support is automatically enabled using Native Multipathing (NMP) for all Shared PERC 8 cards in Dell versions of the ESXi operating systems.
Currently, Linux support is not offered by Dell on fault tolerant VRTX configurations.

Follow the documentation in this section to remove or install a Shared PERC 8 card under different scenarios.
For information on how to install a Shared PERC 8 card, see Installing The Shared PERC 8 Card.
For information on the post-installation tasks, see Post-Installation Tasks For Shared 8 Card.
When replacing an existing Shared PERC8 card in the PowerEdge VRTX system, perform the steps in this chapter to ensure proper functionality of the shared storage after the replacement process is complete.
In the Single Shared PERC 8 card configuration, the shared PERC slot is labeled as INT_STORAGE_1 on the PowerEdge VRTX system board. In the Fault Tolerant Shared PERC 8 card configuration, the shared PERC slots are labeled as INT_STORAGE_1 and INT_STORAGE_2 on the PowerEdge VRTX system board. To locate the Shared PERC slots, see System Board Connectors in the Dell PowerEdge VRTX Enclosure Owner's Manual at dell.com/poweredgemanuals
Controller firmware package 23.8.10-0059 is the minimum firmware package version required for fault tolerant Shared PERC 8 configurations on PowerEdge VRTX.
For more information, see the storage subsystem compatibility matrix document at dell.com/support/ home
For information on removing and reinstalling system parts, see the VRTX Enclosure Owner's Manual of the system at dell.com/poweredgemanuals

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the system.
Perform the following steps to enable recovery in the event the part replacement process fails:
the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location. c. Click Chassis Overview → Storage → Virtual Disks to get the virtual disk configuration
information by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the system.

To remove the Shared PERC 8 card:

Figure 1. Removing and Installing the Shared PERC 8 Card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
When the card is fully seated, the release levers snap over the edge of the card.
It may take up to 25 minutes for the PowerEdge VRTX storage subsystem to completely power on.
The firmware version must be same for both the cards.

The VRTX storage subsystem comprises of Shared PERC firmware, drivers, Chassis Infrastructure firmware and the CMC. When updating any of these components, make sure that all the component versions are at a compatible baseline.
Before you begin, download the windows update package for the firmware.

The Dell Shared PowerEdge RAID Controller (PERC) 8 card requires software drivers to operate with the supported operating systems.
This chapter contains the procedures for installing the drivers for the Shared PERC 8 card.
Downloading Drivers and Firmware For Shared PERC 8 From The Dell Support Website For All Operating Systems
NOTE: To download the latest firmware and drivers for a server module (for example Dell PowerEdge M520, M620, and M820), enter the service tag or the model number of the server module. To download the latest firmware and driver for components inside the PowerEdge VRTX chassis (for example Shared PERC 8 firmware and driver), enter the service tag or the model number of the PowerEdge VRTX chassis.
The drivers that are applicable to your selection are displayed.
Downloading Drivers From The Dell Systems Service And Diagnostic Tools Media For Windows
To download drivers from the Dell Systems Service and Diagnostic Tools media:
The Welcome to Dell Service and Diagnostic Utilities screen is displayed.

For the list of supported operating systems, see Supported Operating Systems.
Repeat this step for all the drivers you require.
For more information on reinstalling the operating system, see the relevant document at dell.com/ support/manuals.
This procedure is applicable for updating existing Windows Server 2008 R2 or Windows Server 2012/2012 R2 drivers.
The System Properties screen is displayed.
The Device Manager screen is displayed.
The screen to update the device driver wizard is displayed.

Use the procedures in this section to update the driver for Red Hat Enterprise Linux 6 Update 5 and SUSE Enterprise Linux 11 SP3. To ensure that you have the current version of the driver, download the updated Linux driver from dell.com/support
Perform the following steps to install the RPM package with KMOD support:
Perform the following steps to install the RPM package with KMP support:
For information on how to install drivers on VMware ESXi 5.1 and 5.5, see kb.vmware.com/kb/2005205 For information on VMware ESXi drivers, see the VMware ESXi documentation at dell.com/ virtualizationsolutions.

The Dell Chassis Management Controller (CMC) enables you to:
For more information on the CMC web interface or CLI commands available for Shared PERC 8, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/esmmanuals

To get help with your Dell Shared PowerEdge RAID Controller Shared (PERC) 8 card, you can contact your Dell Technical Service representative or see dell.com/contactdell
Performance is highly variable across configurations, drive type, applications and IO workloads. The write performance of write-through mode is typically lower than that of write-back mode. Some configurations and workloads exhibit significant performance deltas.
Evaluate your needs for maximum I/O performance (a single Shared PERC 8 configuration) versus maximum data protection (a Fault Tolerant Shared PERC 8 configuration).
In the event of some failure conditions encountered at boot, Shared PERC 8 boots with restricted capability in safe mode without user intervention. In such a condition Shared PERC 8 reports all configured disk drives as Foreign to the management application. The Dell Chassis Management Controller (CMC) displays events generated by the Shared PERC 8 card indicating the reason for booting into safe mode. The following table details the conditions and the corresponding event notifications that are reported to the CMC. Table 2. Conditions and the Corresponding Event Notifications Reported to the CMC
Category Event Reported To the CMC Description of the Failure
Controller cache pinned for missing or offline VDs: %s
The Shared PERC 8 card preserves dirty cache for a virtual disk that transitioned to offline or was deleted due to missing physical disks.
You can restore the preserved cache to the virtual disk once the original drives are re- inserted and the foreign configuration is imported.
Controller booted to safe mode due to critical errors Critical Error during boot - On-board expander FW or mfg image is corrupted - reflash image
This issue occurs if expanders are not detected.
Reseat and cable the expanders.
Corrective Action · Pinned Cache · SAS Discovery

Category Event Reported To the CMC Description of the Failure
Critical Error during boot - NVDATA image is invalid - reflash NVDATA image
The NVData image is invalid.
Contact Dell Technical Support.
A redundant virtual disk is in a degraded state when one or more physical disks have failed or are inaccessible. For example, if a RAID 1 virtual disk consists of two physical disks and one of them fails or becomes inaccessible, the virtual disk becomes degraded.
To recover a virtual disk from a degraded state, you must replace the failed physical disk and rebuild it. After the rebuilding process is complete, the virtual disk state changes from degraded to optimal.
Issue: The device is displayed in Device Manager but has a yellow exclamation mark (!).
Corrective Action:
Reinstall the driver. For more information on reinstalling drivers, see Driver Installation. If reinstalling the driver does not resolve the yellow exclamation mark, perform a shutdown of all server modules and power cycle the chassis.
Issue: The device does not appear in the Device Manager.
Corrective Action:
In the Dell Chassis Management Controller (CMC) application, verify if the Shared PERC 8 is correctly mapped to the server module. For more information on assigning virtual adapters to server slots, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/poweredgemanuals
If the Virtual Adapter to Server Slot mapping is correct and the device still does not appear in the Device Manager, turn off the system and reseat the Shared PERC 8 card.
Issue: Error messages such as Critical Event11, PERCSAS2The driver detected a controller error on \Device\RaidPort...
Corrective Action · or,

The IO operation at logical block address xxxxxx for Disk x was retried
referring to the PercSAS2 driver is seen in the Windows Event log .
Corrective Action:
These error messages may be triggered under some non-critical cases. See the system status and the CMC logs to identify any persistent failures.
Issue: Shared PERC 8 cards fail to function in systems with the Fault Tolerant Shared PERC 8 card configuration.
Corrective Action:
This issue may occur if the Shared PERC 8 card property settings between the two Shared PERC 8 cards is not compatible. Make sure that the firmware packages are identical for both the Shared PERC 8 cards.
Issue: The number of disks displayed in Windows Disk Manager is more than the actual number of virtual disks assigned to the server.
Corrective Action:
This issue occurs if the MPIO feature is not installed in systems with the Fault Tolerant Shared PERC 8 card configuration. Install MPIO services from the list of features that can be installed on the server. For instructions on how to install MPIO, see Installing and Configuring MPIO at technet.microsoft.com.
Issue: One of the physical disks in the disk array is in the failed state.
Corrective Action:
Update the Shared PERC 8 cards to the latest firmware available on dell.com/ support. Replace the physical disk with a working one which is compatible with the old physical disk and is of equal or greater capacity.
Issue: Cannot rebuild a fault tolerant virtual disk. For more information, see the alert log for virtual disks.
Corrective Action:
The replacement disk is too small or not compatible with the virtual disk. Replace the failed disk with a compatible good physical disk with equal or greater capacity.

Issue: Fatal error(s) or data corruption(s) is reported when accessing virtual disks.
Corrective Action:
Contact Dell Technical Support.
Issue: One or more physical disks are displayed as Blocked and cannot be configured.
Corrective Action:
Ensure the physical disk is supported by SCSI-3 Persistent Reservation (PR). Update the physical disk and Shared PERC 8 to the latest firmware available on dell.com/ support.
Issue: Multiple disks become simultaneously inaccessible.
Corrective Action:
Multiple physical disk errors in a single array indicate a failure in cabling or connection and can involve loss of data. Perform the following steps to recover the virtual disk:
If the virtual disk is redundant and transitioned to Degraded state before going Offline, a rebuild operation starts automatically after the configuration is imported. If the virtual disk has gone directly to the Offline state due to a cable pull or power loss situation, the virtual disk is imported in its Optimal state without a rebuild occurring.
Issue: Rebuilding a physical disk after one of them is in a failed state.
Corrective Action:
If you have configured hot spares, the Shared PERC 8 card automatically tries to rebuild a physical disk that is in a failed state. The automatic rebuild is not available if there is no hot spare with enough capacity to rebuild the failed physical disk. You

must make sure a physical disk with enough storage in the subsystem is set as a hot spare for rebuilding the physical disk.
Issue: A virtual disk fails during rebuild while using a global hot spare. The global hot spare reverts to Hotspare state and the virtual disk is in Failed state.
Corrective Action:
Check whether the original virtual disk has failed or has been removed.
Issue: A virtual disk fails during rebuild while using a dedicated hot spare. The dedicated hot spare goes to Ready state and the virtual disk goes to Failed state.
Description: Check whether the original virtual disk has failed or has been removed.
Issue: A physical disk is taking longer than expected to rebuild.
Description: A physical disk takes longer to rebuild when under high stress. For example, there is one rebuild I/O operation for every five host I/O operations. You cannot add a second virtual disk to a disk group while the virtual disk in that disk group is undergoing a rebuild. The firmware does not allow you to create a virtual disk using the free space available in a disk group if a physical disk in a virtual disk group is undergoing a rebuild operation.
For certain conditions virtual drives will be either not configured to write-back caching or if configured, it will transition to write-through caching. The status of write-back caching can be viewed through CMC storage logs.
The following table details the conditions and the corrective actions.
Table 3. Conditions and the corrective actions
During the VRTX power on with no failing conditions, the virtual drive temporarily transitions to write-through as part of the Shared PERC 8 firmware initialization. After the system power on, the virtual drive transitions back to write-back.
There is no intervention required.
Perform the following:
During VRTX power on or reset, unresolved pinned cache is present.
Conditions Actions

During a Shared PERC firmware flash, virtual drive transitions to write-through until chassis is recycled.
Allow the chassis reset to complete after the firmware flash.
Virtual drives permanently transition to write- through when Hardware failure occurs.
If hardware failure occurs, contact Dell technical support. For more information, see the Getting help.
In the event of a firmware mismatch, in the dual fault tolerant Shared PERC 8 configurations, if one controller has write-through capability and the other does not, virtual drives on the controller with write-through capability reverts to write-through.
Update the firmware such that both cards are running the latest supported versions available.
Self Monitoring and Reporting Technology (SMART) monitors the internal performance of all motors, heads, and physical disk electronics and detects predictable physical disk failures.
Issue: A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective Action:
Perform the following steps:
Conditions Actions

Issue: A SMART error is detected on a physical disk in a non-redundant virtual disk.
Corrective Action:
Perform the following steps:
Issue: The source disk fails during the Auto Replacement Member operation.
Description: If the source data is available from other disks in the virtual disk, the rebuild begins automatically on the target disk, using the data from the other disks.
Issue: The target disk fails.
Description: If the target disk fails, the Auto Replacement Member operation is terminated.
Issue: A general disk fails.
Description: If the target disk fails and the Auto Replacement Member operation terminates but the source data is still available, then the Auto Replacement Member operation continues as Auto Replacement Member.


Figure 2. Hard-Drive Indicators
Drive-Status Indicator Pattern Condition
Blinks green two times per second Identifying drive or preparing for removal
Off Drive ready for insertion or removal
Blinks green, amber, and off Predicted drive failure
Blinks amber four times per second Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three seconds, and off six seconds
Rebuild aborted

Contacting Dell
Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:
a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.
The support page that lists the various support categories is displayed.
a. Select your product category. b. Select your product segment. c. Select your product.
The support page that lists the various support categories is displayed.
Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.
If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit to send your feedback.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.