Information in this document is subject to change without notice. © 1998–1999 Network Appliance, Inc. Licensed to Dell Computer Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
No part of this book covered by copyright may be reproduced in any form or by any means—graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system—without prior written permission of the copyright owner.
Portions of this product are derived from the Berkeley Net2 release and the 4.4-Lite-2 release, which are copyrighted and publicly distributed by The Regents of the University of California.
Copyright © 1980–1995 The Regents of the University of California. All rights reserved.
Portions of this product are derived from NetBSD, which is copyrighted and publicly distributed by Carnegie Mellon University.
Copyright © 1994, 1995 Carnegie Mellon University. All rights reserved. Author Chris G. Demetriou.
Permission to use, copy, modify, and distribute this software and its documentation is hereby granted, provided that both the copyright notice and its permission notice appear in all copies of the software, derivative works or modified versions, and any portions thereof, and that both notices appear in supporting documentation.
CARNEGIE MELLON ALLOWS FREE USE OF THIS SOFTWARE IN ITS “AS IS” CONDITION. CARNEGIE MELLON DISCLAIMS ANY LIABILITY OF ANY KIND FOR ANY DAMAGES WHATSOEVER RESULTING FROM THE USE OF THIS SOFTWARE.
Software derived from copyrighted material of The Regents of the University of California, Carnegie Mellon University, and Network Appliance are subject to the following license and disclaimer:
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
Redistributions of source code must retain the above copyright notices, this list of conditions, and the following disclaimer.
Redistributions in binary form must reproduce the above copyright notices, this list of conditions, and the following disclaimer in the documentation and/or other materials provided with the distribution.
All advertising materials mentioning features or use of this software must display the following acknowledgment:
This product includes software developed by the University of California, Berkeley and its contributors.
Neither the name of the University nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Network Appliance reserves the right to change any products described herein at any time, and without notice. Network Appliance assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by Network Appliance. The use and purchase of this product do not convey a license under any patent rights, trademark rights, or any other intellectual property rights of Network Appliance.
The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications.
RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7103 (October 1988) and FAR 52-227-19 (June 1987).
Trademarks used in this text: Dell, the DELL logo, Dimension, Inspiron, OptiPlex, Latitude, PowerEdge, and PowerVault are trademarks and DellWare is a service mark of Dell Computer Corporation; the Network Appliance logo is a registered trademark and Network Appliance and Data ONTAP are trademarks of Network Appliance, Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation disclaims any proprietery interest in trademarks and trade names other than its own.
April 1999 P/N 3385P Rev. A00


Use the following safety guidelines to ensure your own personal safety and to help protect your computer or storage system from potential damage.
Throughout this guide, blocks of text may be accompanied by an icon and printed in bold type or in italic type. These blocks of text are notes, cautions, and warnings, and they are used as follows:
!"# !"# $
Observe the following warnings while servicing this system:
!"# % & " % ' % ( % )
!"# * % *
!"# % + + ' % %
!"# $ % &'( ) *+,+% -* ,. '%*+ %/ !*.0 # .1 & 2%'/ * + $+% !30 !* "04 * +. . 0!#+' 2 $ !"# % &'(

(,"-./ ( + 0 +% 1 + + + 0 %0 + + + % 0 +% 0
,"- 22 $2$ 22 + + $ -2' +3+ 2 + +3 +++ $ $2$ 2
! "# $ %&$ ' ( # ) $ #* " "$ ) '
5 6 5 7 +8 9+: # +7 #0 % &' , +' + ( ;& ,+#,8 *,% !* 7+ !* $+% &=.>+(
(,"-./4 ( 5 0 6 0 . + + 6 + % 0 ' 0 0 6
,"# ( + 2 +% . % 3 + + 6 + 2 +% 3 3 + + 3 + + 3
To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the following precautions.
Observe the following general precautions for using and working with your system:
Observe and follow service markings. Do not service any Dell product except as explained in your Dell system documentation. Opening or removing covers that are marked with the triangular symbol with a lightning bolt may expose you to electrical shock. Components inside these compartments should be serviced only by a Dell authorized service technician. If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your Dell authorized service provider:
— The power cable, extension cord, or plug is damaged.
— An object has fallen into the product.
— The product has been exposed to water.
— The product has been dropped or damaged.
— The product does not operate correctly when you follow the operating instructions.

Keep your system components away from radiators and heat sources. Also, do not block cooling vents. Do not spill food or liquids on your system components, and never operate the product in a wet environment. If the computer gets wet, see the appropriate chap- ter in your troubleshooting guide or contact a Dell-authorized service provider. Do not push any objects into the openings of your system components. Doing so can cause fire or electric shock by shorting out interior components. Use the product only with Dell products or other Dell-approved equipment. Allow the product to cool before removing covers or touching internal components. Use the correct external power source. Operate the product only from the type of power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult your Dell service provider or local power company. To help avoid damaging your system components, be sure the voltage selection switch (if provided) on the power supply is set to match the power available at your location:
— 115 volts (V)/60 hertz (Hz) in most of North and South America and some Far Eastern countries such as South Korea and Taiwan
— 100 V/50 Hz in eastern Japan and 100 V/60 Hz in western Japan
— 230 V/50 Hz in most of Europe, the Middle East, and the Far East
Also be sure that your monitor and attached peripherals are electrically rated to operate with the power available in your location.
Use only approved power cable(s). If you have not been provided with a power cable for your computer or storage system or for any AC-powered option intended for your system, purchase a power cable that is approved for use in your country. The power cable must be rated for the product and for the voltage and current marked on the product’s electrical ratings label. The voltage and current rating of the cable should be greater than the ratings marked on the product. To help prevent electric shock, plug the system components and peripheral power cables into properly grounded electrical outlets. These cables are equipped with three-prong plugs to help ensure proper grounding. Do not use adapter plugs or remove the grounding prong from a cable. If you must use an extension cord, use a three-wire cord with properly grounded plugs. Observe extension cord and power strip ratings. Make sure that the total ampere rating of all products plugged into the extension cord or power strip does not exceed 80 percent of the extension cord or power strip ampere ratings limit. Do not use appliance/voltage converters or kits sold for appliances with your Dell product. To help protect your system components from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or un- interruptible power supply (UPS).

Position cables and power cords carefully; route cables and the power cord and plug so that they cannot be stepped on or tripped over. Be sure that nothing rests on your system components’ cables or power cord. Do not modify power cables or plugs. Consult a licensed electrician or your power company for site modifications. Always follow your local/national wiring rules. To help avoid possible damage to the system board, wait 5 seconds after turning off the system before removing a component from the system board or discon- necting a peripheral device from the computer. Handle batteries carefully. Do not disassemble, crush, puncture, short external contacts, dispose of in fire or water, or expose batteries to temperatures higher than 60 degrees Celsius (140 degrees Fahrenheit). Do not attempt to open or ser- vice batteries; replace batteries only with batteries designated for the product. Turn down the volume before using headphones or other audio devices.
Observe the following additional safety guidelines for your system:
Unless your installation and/or troubleshooting documentation specifically allows it, do not remove enclosure covers, attempt to override the safety interlocks, or access any components inside the system. Depending on your system, installa- tion and repairs may be done only by individuals who are qualified to service your computer or storage system equipment and trained to deal with products capa- ble of producing hazardous energy levels. When connecting or disconnecting power to hot-pluggable power supplies, if offered with your Dell product, observe the following guidelines:
— Install the power supply before connecting the power cable to the power supply.
— Unplug the power cable before removing the power supply.
— If the system has multiple sources of power, disconnect power from the sys- tem by unplugging all power cables from the power supplies.
Move products with care; ensure that all casters and/or stabilizers are firmly con- nected to the computer or storage system. Avoid sudden stops and uneven surfaces.
Observe the following precautions for rack stability and safety. Also refer to the rack installation documentation accompanying the system and the rack for specific warn- ing and/or caution statements and procedures.
!"# ( ( + %* + ' % $ %* % +

!"# + + % & + $
NOTE: Dell’s server and storage systems are certified as components for use in Dell’s rack cabinet using the Dell customer rack kit. The final installation of Dell systems and rack kits in any other brand of rack cabinet has not been approved by any safety agen- cies. It is the customer’s responsibility to have the final combination of Dell systems and rack kits for use in other brands of rack cabinets evaluated for suitability by a certi- fied safety agency.
System rack kits are intended to be installed in a Dell rack by trained service tech- nicians. If you install the kit in any other rack, be sure that the rack meets the specifications of a Dell rack. Do not move large racks by yourself. Due to the height and weight of the rack, Dell recommends a minimum of two people to accomplish this task. Before working on the rack, make sure that the stabilizers are secure to the rack, extend to the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack. Always load the rack from the bottom up, and load the heaviest item in the rack first. Make sure that the rack is level and stable before extending a component from the rack. Extend only one component at a time from the rack. Use caution when pressing the component rail release latches and sliding a com- ponent into or out of a rack; the slide rails can pinch your fingers. After a component is inserted into the rack, carefully extend the rail into a locking position, and then slide the component into the rack. Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not exceed 80 percent of the branch circuit rating. Ensure that proper airflow is provided to components in the rack. Do not step on or stand on any system/component when servicing other systems/ components in a rack.
!" # $%
Observe the following guidelines when working with options:
Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical shock from lightning. Never connect or use a modem or telephone in a wet environment. Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.

Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack. Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
Observe the following precautions for laser devices:
Do not open any panels, operate controls, make adjustments, or perform proce- dures on a laser device other than those specified in the product’s documentation. Only authorized service technicians should repair laser devices.
Before you remove the computer covers, perform the following steps in the sequence indicated.
!"# - ( % % ' % * ( & & (
% % 7 ' % %
While you work, periodically touch an unpainted metal surface on the computer chassis to dissipate any static electricity that might harm internal components.
Doing so reduces the potential for personal injury or shock.
In addition, take note of these safety guidelines when appropriate:
When you disconnect a cable, pull on its connector or on its strain-relief loop, not on the cable itself. Some cables have a connector with locking tabs; if you are dis- connecting this type of cable, press in on the locking tabs before disconnecting the cable. As you pull connectors apart, keep them evenly aligned to avoid bending any connector pins. Also, before you connect a cable, make sure that both connectors are correctly oriented and aligned.

Handle components and cards with care. Don’t touch the components or con- tacts on a card. Hold a card by its edges or by its metal mounting bracket. Hold a component such as a microprocessor chip by its edges, not by its pins.
!"# % & " % ' % ( % )
Static electricity can harm delicate components inside your computer. To prevent static damage, discharge static electricity from your body before you touch any of your computer’s electronic components, such as the microprocessor. You can do so by touching an unpainted metal surface on the computer chassis.
As you continue to work inside the computer, periodically touch an unpainted metal surface to remove any static charge your body may have accumulated.
You can also take the following steps to prevent damage from electrostatic discharge (ESD):
When unpacking a static-sensitive component from its shipping carton, do not remove the component from the antistatic packing material until you are ready to install the component in your computer. Just before unwrapping the antistatic packaging, be sure to discharge static electricity from your body. When transporting a sensitive component, first place it in an antistatic container or packaging. Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads and workbench pads.
The following notice may appear throughout this document to remind you of these precautions:
!"# - 89 . ( :
!"# + % $
!"# , &
For comfort and efficiency, observe the following ergonomic guidelines when you set up and use your computer system:
Position your system so that the monitor and keyboard are directly in front of you as you work. Special shelves are available (from Dell and other sources) to help you correctly position your keyboard.

Set the monitor at a comfortable viewing distance (usually 510 to 610 millimeters [20 to 24 inches] from your eyes). Make sure that the monitor screen is at eye level or slightly lower when you sit in front of the monitor. Adjust the tilt of the monitor, its contrast and brightness settings, and the lighting around you (such as overhead lights, desk lamps, and the curtains or blinds on nearby windows) to minimize reflections and glare on the monitor screen. Use a chair that provides good lower back support. Keep your forearms horizontal with your wrists in a neutral, comfortable position while you use the keyboard or mouse. Always leave space to rest your hands while you use the keyboard or mouse. Let your upper arms hang naturally at your sides. Sit erect, with your feet resting on the floor and your thighs level. When sitting, make sure the weight of your legs is on your feet and not on the front of your chair seat. Adjust your chair’s height or use a footrest, if necessary, to maintain proper posture. Vary your work activities. Try to organize your work so that you do not have to type for extended periods of time. When you stop typing, try to do things that use both hands.
monitor screen at or below eye level

wrists relaxed and flat
monitor and keyboard positioned directly in front of user
arms at desk level
feet flat on the floor

!
This guide describes how to install a PowerVault 720N, 740N, or a 760N filer in a rack, connect it to a PowerVault 700N Disk-Array Enclosure (DAE) storage system and to an optional tape backup device, and start up the system. The chapters in this guide are summarized as follows:
Chapter 1, “Introducing the Dell PowerVault 720N, 740N, and 760N Filers” introduces the standard and optional features and gives the slot assign- ments for the supported expansion cards for the three filers. Chapter 2, “Installing a Filer System” provides detailed procedures for installing a filer in a rack and cabling the filer to PowerVault 700N storage system(s) and to a tape backup device. Chapter 3, “Troubleshooting the Filer Hardware” provides information on trouble- shooting the filer, based on light-emitting diode (LED) status displays and liquid-crystal display (LCD) panel error and informational messages. Chapter 4, “Getting Help” describes the help tools Dell provides to assist you should you have a problem with the filer. It also explains how and when to call Dell for technical assistance. Chapter 4 also includes a diagnostics checklist that you can copy and fill out as you perform the troubleshooting procedures. If you need to call Dell for technical assistance, use the completed checklist to tell the Dell technical support representative what procedures you performed to better help the representative give you assistance. If you must return a piece of hard- ware to Dell, include a filled-out checklist.
This guide is for system administrators and trained computer equipment installation technicians who are familiar with network data servers and how the Network File Sys- tem (NFS), Common Internet File System (CIFS), and Hypertext Transfer Protocol (HTTP) protocols are used to share and transfer files.

This guide uses the following terms:
Filer refers to a PowerVault 720N, 740N, or 760N network data server. System refers, at a minimum, to a filer and a connected PowerVault 700N storage system. An optional tape backup device can also be a component of the system. Disk storage system refers to a single PowerVault 700N storage system or a fibre channel-arbitrated loop (FC-AL) of several PowerVault 700N storage systems.
In addition to this guide, the following documentation is included with your system or with the PowerVault 700N storage system:
The Dell PowerVault 720N, 740N, and 760N Storage System Installation and Ser- vice Guide, for installing and servicing the PowerVault 700N storage system. The Dell PowerVault 720N, 740N, and 760N User’s Guide for using the filer. Getting Started With the Dell PowerVault 7xxN Storage System for initial setup and cabling of the filer and attached PowerVault 700N storage system units. The Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for setting up and administering the filer. The Dell PowerVault 720N, 740N, and 760N Quick Reference card for a quick ref- erence to commands used to administer and use the filer.
You may also have one or more of the following documents.
Operating system documentation is included if you ordered your operating sys- tem software from Dell. This documentation describes how to install (if necessary), configure, and use your operating system software. Documentation is included with any options you purchase separately from your system. This documentation includes information that you need to configure and install these options in your Dell computer. Technical information files—sometimes called “readme” files—may be installed on your hard-disk drive to provide last-minute updates about technical changes to your system or advanced technical reference material intended for experienced users or technicians.

Table 1 lists the kinds of formatting this guide uses to identify special information.
Italic type Words or characters that require special attention. File names and path names. Placeholders for information you must supply. For example, if the guide says to enter the arp -d hostname command, you enter the characters “arp -d” followed by the actual name of the host. Manual page names. Book titles in cross-references.
Monospaced font Command and daemon names. Information displayed on the system console or other computer monitors. The contents of files.
Words or characters you type. What you type is always shown in lowercase letters, unless you must type it in uppercase letters for it to work properly.
This guide contains special messages that are described as follows:
!"# !"# $
Bold monospace font




%&'$(%)'$( %*'$+
Dell™ PowerVault™ 720N, 740N, and 760N filers are dedicated, special-purpose net- work data servers that provide fast and reliable file service to network clients connected to Ethernet networks.
The 720N, 740N, and 760N filer differences are based on performance, capacity, and networking.
The filer standard features are described in three parts—those that you can see from the front panel, those that you can see with the front bezel removed, and those that you can see from the back panel.
Introduction 1-1

Figure 1-1 shows the standard features that you can see from the front panel.

Table 1-1 describes the front panel features.
Installation Brackets When you install the filer in an equip- ment rack, you attach its installation brackets to the front rails of the rack.
A right-angle mounting bracket running the length of each side of the filer chas- sis rests on similar brackets mounted inside each side of the rack cabinet.
LEDs (Light Emitting Diodes) The LEDs on the front panel report sys- tem status and network activity. A glance at these LEDs lets you know right away whether the filer requires troubleshooting.
The LEDs are described in the section, “LEDs on the front and back panel,” in Chapter 3.
Activity LED · Status LED · Power LED

Figure 1-2 shows the standard features that you can see with the front bezel removed.

Table 1-2 describes the features that you can see after the front bezel is removed.
Reset Button This button is behind the front bezel so that you cannot reset the filer inadvert- ently. It enables you to reset the filer in those rare cases when the system fails or you upgrade the software.
To reset the filer, remove the front bezel and push the reset button, located below the power LED.
Diskette Drive This drive enables you to boot the sys- tem from a diskette when the system fails to start from the hard disk. You also use this drive to run diagnostics using the diagnostics diskette.
LCD (Liquid Crystal Display) The LCD displays status, error, and diag- nostic messages up to 32 characters long.
The LCD messages are described in the section, “LCD messages,” in Chapter 3.
Reset button · Diskette drive · Introduction 1-3

Figure 1-3 shows the standard features that you can see from the back panel.

10/100 Base-T Ethernet interface
CONSOLE port FC-AL0 Fibre Channel interface
!
Table 1-3 describes the back panel features.
!
The built-in interface provides a 10Base-T or 100Base-T Ethernet connection. The interface automatically deter- mines the medium type (10Base-T or 100Base-T). Two LEDs report on the status of the interface (see LEDs on the front and back panels, in Chapter 3). You do not need to order an Ethernet Network Interface Card (NIC).
SCSI Tape Interface The built-in, wide differential SCSI (Small Computer Sys- tem Interface) interface provides a connection to a SCSI tape backup device.
Power Supplies The filer comes with two autoranging power supplies. The first power supply, on the left side, is labeled PS 1; the second is labeled PS 2.
Each power supply provides +5V, +3.3V, +12V, and -12V output DC power. Two LEDs report on its status. A retaining clip secures the power cord to the filer.
Two power supplies provide:
Redundancy—When one power supply fails, the other takes over and provides power for the filer until you replace the failed power supply. Hot swapping—You can replace one power supply while the second is running without disrupting service.
NVRAM card · SCSI tape interface · 10/100Base-T Ethernet interface

!
Serial Port CONSOLE port—Provides a console connection from which you can monitor and manage the filer.
After you install the filer in a rack, you configure it for network operation from the console. Later, you can use the console to access and manage the filer when a remote connection is not available.
FC-AL Disk Interface The built-in interface provides an FC-AL (Fibre Channel Arbitrated Loop) connection to the Dell PowerVault 700N Disk-Array Enclosure (DAE) storage system with 18-GB disk drives.
NVRAM Card This card provides Non-Volatile Random Access Memory. It stores in-transit data before the data is permanently written to disk.
An optional feature is a feature that you can use or order for your system to supple- ment the standard features.
The optional features fall into five categories:
Your filer ships with the optional features you selected installed. You can also order optional features later.
You can order the following Ethernet NICs for additional network connectivity:
Figure 1-4 shows the back panel of a filer with two quad-port 10/100Base-T Ethernet cards installed in slots 1 and 2, and a GB Ethernet card installed in slot 6.
· Introduction 1-5


Two 10/100 Base-T quad-port Ethernet cards
"# $ !%
You can order an FC-AL adapter for additional fibre channel disk storage.
Table 1-4 shows how much fibre channel disk storage capacity each filer supports. The number of loops includes the loop connected to the built-in FC-AL interface.
" & ' ( !&(
$ %
!" # $
720N None One 30 0.5 TB
740N One Two 60 1.0 TB
760N Two Three 80 1.5 TB
The FC-AL disk adapters in all three PowerVault Filers are supported by one or more PowerVault 700N storage systems.
!"
The filer has nine expansion slots on the system board. Slot 9 is dedicated to the NVRAM card. The remaining eight expansion slots are for additional cards and adapt- ers that enable you to expand your network connectivity and disk storage capacity.
GB Ethernet card ·

The connectors of the cards and adapters installed in the slots fit through the slot openings in the filer’s back panel. Figure 1-5 shows the expansion slots as viewed from the back panel.

Slot 9 dedicated to NVRAM card
)#*( '
# Table 1-5 shows the available slots on each filer. The bullet () indicates an avail- able slot. Shaded boxes indicate unavailable slots.
)& +&
! & ' ( ) * + " ,
740N
760N
Introduction 1-7

Table 1-6 gives the slot assignments for the available three slots on the 720N.
, & - ./
! & ' ( ) * + " ,

Table 1-7 gives the slot assignments for the available six slots on the 740N.
. & - ."/
! & ' ( ) * + " ,

Table 1-8 gives the slot assignments for the available eight slots on the 760N.
0 & - .,/
! & ' ( ) * + " ,

$%& # · $'& # · $(& #

As a network data server, the function of the PowerVault 720N, 740N, or 760N filer is to move data over the network in response to a client request. The filer uses Data ONTAP™ operating system software to do so. The data is stored on storage disks that reside in PowerVault 700N storage systems connected to the filer. In addi- tion, a SCSI tape backup device is recommended for regular backups to protect your data. Therefore, a complete system consists of a filer connected to one or more PowerVault 700N storage systems, plus an optional (but recommended) tape backup device.
)*
Figure 1-6 shows a filer installed in a rack above two daisy-chained PowerVault 700N storage systems, and a tape backup device.
Introduction 1-9


two PowerVault 700N storage systems
SCSI tape backup device
,&1( $2 1 -
filer

", , -.
The following list provides an overview of the procedures you perform to install the filer and the rest of the units in the system:
Preparing for the installation Installing the filer in a rack Connecting the filer to a PowerVault 700N Disk-Array Enclosure (DAE) storage system Connecting the filer to the network Establishing a console terminal connection to the filer Connecting the system to a power source
This chapter provides instructions for installing the filer and connecting the PowerVault 700N storage system and backup tape device for the first time
Before you install your system, make sure that you meet the following tools, equip- ment, environmental, electrical, space, and location requirements.
;
Installing a Filer System 2-1

!+ , +
You need the following tools and equipment to install the filer.
A 19-inch (483-mm.) rack conforming to ANSI/EIA-310-D-92. If you do not install the system components in a rack, you must provide additional grounding. Phillips #1 and #2 screwdrivers. A cage-nut installation tool (included in the rack mounting kit). A torque-measuring wrench capable of measuring up to 30 inch-pounds (3.389 newton-meters) torque.
!- , +
Table 2-1 lists the environmental requirements.
-( 3- 145 -
- . .
Temperature range 50° F to 104° F (10° C to 40° C)
–4° F to 149° F (–20° C to 65° C)
Relative humidity 10% to 90% (noncondensing)
5% to 90% in original shipping container (noncondensing)
! , +
Table 2-2 lists the electrical power requirements.
# $45 -
/ 0
Power supply 90 to 250V AC single phase
Maximum current 4A at 90V AC (RATED)
Frequency 47 to 63 Hz
Watts 300 max. (with Power Factor)
BTU/hr 1025 max.
Otherwise, 50% (noncondensing) · 12 /

, +
Table 2-3 gives the filer’s dimensions and weight.
#5 (- - 6 76 8
$ 3 4 / 5 6
Height 9.625 in 24.4 cm 5.5 U (1 U =1.75 inch)
Width 17 in 43.18 cm
Depth 25.25 in 64.14 cm
Weight* 64 lbs. 29 kg.
*Weight with all expansion slots filled.
Table 2-4 describes the recommended minimum clearance for the filer.
" 45 - 76 8
/
Front clearance 22.86 cm 9.0 in.
Back clearance 170.2 cm 67 in.
Additional work space in back 60.96 cm 24 in.
Vertical rack space 24.4 cm 9.625 in.
Top clearance, only in back 22.2 mm 0.875 in.
Ensure that your shipment package includes:
One or more filers with the expansion cards you ordered installed in the filer Two power cords (one for each power supply) FC-AL cables for connecting the filer to the PowerVault 700N storage system A disposable electrostatic discharge (ESD) wrist strap and grounding leash Documentation kit with software Diagnostic loopback cable (for Ethernet NIC) Serial console cables (one straight through cable, one null modem cable)
Installing a Filer System 2-3

— Two rack adapter rails and mounting hardware
— A 1/2-U filler panel and mounting hardware (including cage nuts and cage nut
— A cable management clip with mounting hardware
Observe the following requirements, cautions, and warnings when you install the filer in a rack (the filer ships with front installation brackets installed).
Ensure that the rack mounting holes meet ANSI/EIA-310-D-92 specifications for 19-inch (483-mm.) wide equipment. Ensure that equipment installed above the filer is no closer than 0.875-inch (22.2-mm) from the top of the filer’s ventilation holes.
; .-( % .-( % .-( .-(
!"# ?@ AB + C $ + ' +
! 9 , DAA 1% ' % / ( + 1 ( 9 , DAA ( +
The left- and right-hand rack adapter rails have six threaded holes on the front and four on the back. The multiple holes allow users to install the rack adapter rails in either whole-unit or half-unit rack mount positions. The six threaded holes are labeled 1 through 6 on the front and 7 through 10 on the back, with stamped numbers.
To install the rack adapter rails in a standard 19-inch (483-mm.) equipment rack, per- form the following steps:
installation tool)

front vertical rail 1-U marking on vertical rail

1/2-U increment in vertical rail IU grouping of three evenly-spaced holes
align lower edge of support rail with one of these locations
1-U increment in vertical rail
4 !2 4 76 9:!8
a. At the front of the rack, install the rack adapter rail using threaded holes 1 and 5 for whole-U positions and holes 2 and 6 for half-U positions (see Figure 2-2).
b. Secure the front of each rack adapter rail with two 10-32 x 0.375-inch coun- tersunk screws with conical washers provided with the mounting hardware (see Figure 2-2).
c. Using a torque-measuring wrench, tighten the rack adapter rail to the vertical rail to 27 inch pounds (3.0 newton meters).
Installing a Filer System 2-5

Whole-U Alignment Half-U Alignment

conical washer 10-32 x 0.375-inch countersunk screws
4 !&( 4 +6 9 39 & -
d. At the back of the rack, secure the rack adapter rail to the rack’s vertical rail using two 10-32 x 0.375-inch screws and conical washers.
If you used hole numbers 1 and 5 at the front of the rack, hole numbers 8 and 10 will align to holes on the vertical rail (for whole-U alignment).
If you used hole numbers 2 and 6 at the front of the rack, hole numbers 7 and 9 will align to holes on the vertical rail (for half-U alignment). See Figure 2-3.
e. Using a torque-measuring wrench, tighten the rack adapter rail to the vertical rail to 27 inch pounds (3.0 newton meters).
Figure 2-4 shows the rack adapter rails properly positioned in the rack.
rack adapter rail · rack vertical rail · 1-U spacing mark


! 4 !&( 4 +6 9 39 & -

"% 4 !&( 4
Installing a Filer System 2-7

To install the filer after the rack adapter rails are installed inside the rack, perform the following steps:
The half-U filler panel provides the proper spacing between the installed filer and other equipment installed in the rack, such as the PowerVault 700N storage system or a tape backup device. Mounting hardware for the filler panel consists of two 10-32 x 0.625-inch screws and two 10-32 cage nuts.
Perform the following steps to install the cage nuts and install the filler panel:
By installing the filler panel one way or the other (inverted), you can achieve the proper fit, whether the filer occupies whole-unit or half-unit rack positions.


)%
Your installed filer should look similar to Figure 2-6.

, % 4 !
Installing a Filer System 2-9

A cable management kit is provided with the filer. This kit consists of a large plastic cable management clip and two self-tapping screws. When properly installed, cables are routed from the back of the filer, through the circular loop of the plastic cable man- agement clip, to the PowerVault 700N storage system, network receptacle, or to the tape backup device.
Cables routed through the cable management clip represent a service loop at the back of the filer. When a trained service technician needs to perform service inside the filer, the cable management clip is opened and the cables are released from the clip. The technician opens the drawer on the back of the filer without putting unneces- sary tension on installed cable connections.
The clip must be oriented so that the latch is at the top of the clip.
Your installation may look similar to Figure 2-7.
Depending on the rack you are using, you may have to first drill a pilot hole for the self-tapping screws.
( % %
Ensure that the cable management clip is easily opened and closed.

select any two holes
.: - (%

To connect the filer to a single PowerVault 700N storage system (or to as many as eight PowerVault 700N storage systems when cabled as a daisy-chain) you use the filer’s built-in FC-AL (DB-9) interface.
To connect a second or third loop of Fibre Channel PowerVault 700N storage systems to the 740N or 760N filer, you need an FC-AL adapter card installed in the filer for each additional loop. If you order the adapter after your initial order, you must install it yourself.
. # ' , , ' #6 233"
To connect the filer to the first PowerVault 700N storage system (in a single FC-AL loop), perform the following steps:
For a daisy-chain configuration, make sure that the ID on the PowerVault 700N storage system connected to the filer is set to 0.
Figure 2-8 shows the completed connections to the first PowerVault 700N storage system.
Installing a Filer System 2-11


PowerVault 700N Storage System
0 $2 .// 1 -
# ). / $& *
The 740N and 760N support two and three loops of PowerVault 700N storage systems, respectively (each cabled in its own FC-AL loop). Connecting more than one loop enables you to spread the storage load. You must observe the 1.0 TB and 1.5 TB storage limit for the 740N and 760N, respectively.
You connected the first loop of PowerVault 700N storage system(s) to the filer’s built- in FC-AL interface (FC-AL0). You need an FC-AL adapter installed in the filer for each additional loop of PowerVault 700N storage system(s). The PowerVault 700N storage system(s) in each loop are numbered from 0 to 7.
To connect the filer to a second and third loop of PowerVault 700N storage system(s), perform the following steps:
1'/
If you ordered optional FC-AL adapters for your 740N or 760N filer during initial purchase, they are installed in the filer when you receive it. You need to install it yourself if you order it at a later time. Refer to “Slot Assignments,” in Chapter 1, to learn the correct slot number on the 740N and 760N, respectively.
Connector labeled FC-AL0 · PRI connector

In Figure 2-9, the first loop is connected to the FC-AL0 interface of an 760N. The second loop is connected to the FC-AL adapter in slot 7 on the 740N or 760N filer.
The configuration in Figure 2-9 has eight PowerVault 700N storage systems. Such a configuration must be installed in a rack, preferably with the filer located in the middle of the rack and four PowerVault 700N storage systems above and four below the filer. A rack is not shown in the illustration.

FC-AL adapter in slot 7
;$ &' : ( $2 .// 1 -
The third FC-AL loop (loop 2) would be connected using this procedure, but using the FC-AL adapter card in slot 6 for the 740N filer, or using the FC-AL adapter card in slot 4 for the 760N filer.
Installing a Filer System 2-13
FC-AL1 loop · FC-AL0 loop

The filer has a built-in wide differential SCSI tape interface for connecting an external tape backup device.
This SCSI tape interface accepts a standard 68-pin SCSI cable with a maximum length of 17 feet (5 meters).
To install the tape backup device, refer to the documentation shipped with the tape device.
To connect the filer to a tape device, perform the following steps:
If it is not, execute the halt command, then turn off the power on the power supply.
If the filer has two power supplies, turn off both power supplies.
Refer to the documentation for the tape backup device.
% ' ) --
Use the SCSI cable provided with the tape backup device.
( --
Use an active SCSI terminator.
For information about terminating the SCSI bus, refer to the documentation for your tape backup device.

Figure 2-10 shows a SCSI cable connected to the tape backup device and to the con- nector, labeled SCSI TAPE.

SCSI tape backup device
/ % ( !(
You can connect the filer to multiple networks.
This section describes how to connect your filer to an Ethernet network.
During your initial purchase, you order the NICs you need. The filer is shipped with the NICs installed. You can also order additional NICs later.
The NICs’ connectors fit through the slot openings in the filer’s back panel.
Installing a Filer System 2-15

Table 2-5 lists all available network connectivity.
) $ ! 1
25 . 25
GB (1000Base-T) Ethernet
' 8 " #
The filer supports three types of Ethernet NICs: a single-port 10/100Base-T, a quad- port 10/100Base-T, and a GB Ethernet.
! #, +
Table 2-6 lists the cabling requirements for Ethernet connections.
,# 45 -
-4 / 0
10Base-T Category 3 or 5 unshielded twisted- pair (UTP) cable.*
100Base-TX Category 5 UTP cable.*
GB Ethernet Fiber cable.
*Do not exceed the maximum cable length specification.
0. 1&21&& ! .
To connect the filer to a 10/100Base-T Ethernet network, perform the following step:
Use Category 3 (10Base-T only) or Category 5 (10/100Base-T) unshielded twisted- pair (UTP) cable.
Figure 2-11 shows the built-in Ethernet connector.


% # '
0. 3 ! .
To connect the filer to other Ethernet networks, follow this step.
Figure 2-12 shows two quad-port 10/100Base-T cards in slots 1 and 2 and one single-port card in slot 3.

Single-port 10/100Base-T Ethernet card
Two quad-port 10/100Base-T Ethernet cards
# $ !%
Installing a Filer System 2-17
Built-in Ethernet connector

At this point, the filer, PowerVault 700N storage system, and tape backup device are connected and the filer is connected to the network.
You are ready to power on the system. Before you do so, it is a good idea to establish a terminal connection to the filer so that you can observe the system responses on the terminal screen when the system is started. You also need a terminal to set up the filer after you start it.
You can establish a connection to the filer from an ASCII terminal, serial concentrator, or communications server.
This section describes how to connect an ASCII terminal (also referred to as an ANSI terminal) to the filer and how to verify the filer and PowerVault 700N storage system installations.
, +
A DB-9–to–DB-9 straight-through serial cable for an ASCII terminal connection is pro- vided with your filer. If this cable is not compatible with your terminal connector, use a null modem cable.
The filer’s DB-9 serial port supports only DTE devices, not DCE devices such as modems. Most terminals are wired as DTE devices.
The following table lists the pin settings for the DB-9 CONSOLE port.
. & -
$ , 1 $ , 1
1 Data Carrier Detect 5 Ground
2 Receive Data 6 Data Set Ready
3 Transmit Data 7 Request to Send
4 Data Transmit Ready 8 Clear to Send
33 ! #

0.
To connect an ASCII terminal to the filer, perform the following steps:
0 --
1
Line speed 9600 baud
Data bits per character 8
Refer to the documentation for your terminal for further details.
+
Use the provided DB-9–to–DB-9 serial cable.
Figure 2-13 shows the location of the CONSOLE port.

'
#,
If you are connecting an ASCII terminal from a remote site, be sure that you do not have a local terminal connected to the filer’s CONSOLE port.
Installing a Filer System 2-19

You turn on power on to the units in the system in this order:
PowerVault 700N storage systems and tape backup device (any order) PowerVault 720N, 740N or 760N filer last
The PowerVault 700N storage system and disk drives require time to power on, reset, and prepare to respond to the filer. The filer expects them to be ready for input/output when it is turned on and performs its reset and self-test.
The turn-on process automatically:
This section uses a system with three units as an example—filer, PowerVault 700N storage system, and tape backup device. Assume that you have these three units installed and connected in a rack and are ready to turn them on.
0. . / $& * -
To turn on the PowerVault 700N storage system and tape backup device, refer to the documentation for those products.
Do not proceed if the PowerVault 700N storage system(s) or the tape backup device fail to power up. Recheck all connections and the power source, and then retry.
0.
To connect the filer to a power source, perform the following steps:
Figure 2-14 shows two power supplies.


AC power plug clips
" $ ((
The system verifies the filer hardware and loads the operating system.
LEDs on front panel
Power Turns green. StatusTurns yellow, then turns off when the filer starts.
AC LED on power supply
Yellow First turns yellow to indicate that AC power is present. GreenThen turns green to indicate that all outputs are good.
If the LEDs do not light, check your connections and the power source, and retry.
At the end of the initial startup, the default host name prompt filer> appears on the console screen.
The startup messages appearing on the LCD display are described in “LCD Mes- sages,” in Chapter 3.
The filer is ready to be configured.
Installing a Filer System 2-21
AC power switch · AC power plug · status LED



This chapter provides information about how to troubleshoot the PowerVault 720N, 740N, or 760N hardware based on the filer’s light-emitting diode (LED) status indica- tors and system error messages displayed on the liquid crystal display (LCD) panel. It also describes the startup messages that appear when you first start up the system.
!"# * % ' *
- ( &
This chapter does not describe the specific steps necessary to replace expansion cards or internal components of the filer. Refer all servicing of components inside the filer to trained service technicians.
This chapter does not describe system problems related to software configuration, NFS, CIFS, or HTTP. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for information about troubleshooting software problems.
Troubleshooting the Filer Hardware 3-1

The LEDs and LCD are controlled by a built-in environmental controller sensor on the system board that functions as the interface between them and the processor. This controller/sensor monitors environmental conditions, such as the temperature and fan status, and displays signals on the LEDs and messages on the LCD.
Should any corrective action be required, the LCD displays a message. Refer to “LCD Messages” to determine what corrective action is required for a particular message.
Figure 3-1 shows the LEDs on the front panel.

Status LED Power LED
'#
Activity LED

Table 3-1 describes the three LED codes on the front panel.
'# (
-$ 7
Operation/activity is normal.
CPU or network activity detected.
No activity detected.
The system is operating normally.
A fault has occurred or the system has halted. The system requires service. Refer to the LCD mes- sage for a description of the system problem.
The LCD message STDBY/SERV means the filer is in standby mode—a product feature to be implemented in a future software release.
The Status LED turns yellow when you turn on the filer and stays lit while the operating system is loading. It turns off when the filer starts.
Power Green On—The system is on.
Off—The system is down.
. * !
Figure 3-2 shows the power supply LEDs.

AC yellow LED DC green LED
! + $ ((1'#
Troubleshooting the Filer Hardware 3-3

Table 3-2 describes the power supply LED codes on the back panel.
'# (
-$ 7
DC Green On — DC power is good. Off — DC output power is not good.
If the DC green LED is off, contact a service technician to replace the power supply.
If one power supply fails, the message, Power supply degraded . . . appears on the LCD. A similar message appears on the system console telling you which power supply failed. The message, Power good, also appears on the LCD and console, indicating that the second power supply is maintaining the filer.
AC Yellow On—AC signal is good.
Off—AC signal is not good.
If the AC LED is off but the power LED on the front panel is on, the second power supply takes over and maintains the filer. In either case:
Ensure that the power supply is fully installed and locked into place. Ensure that the power switch is in the On position. Check the power source. If the preceding actions do not correct the problem, contact Dell technical support for help.

! !
The built-in 10/100BASE-T Ethernet connector has two LEDs, as shown in Figure 3-3.

Ethernet connector Green LED Yellow LED
% # '#
Table 3-3 describes the LEDs for the built-in 10/100BASE-T Ethernet connector.
% # '# (
-$ 7
Top Green On—Ethernet connection is ready.
Off—No Ethernet connection is present.
Bottom Yellow On—Traffic is passing on the network.
Off—No traffic on the network.
The filer supports a single-port 10/100BASE-T and a quad-port 10/100BASE-T Ethernet card.
# 1&21&&! !
The single-port 10/100BASE-T Ethernet card has one connector and two LEDs, as shown in Figure 3-4.
Troubleshooting the Filer Hardware 3-5


"'# #
Table 3-4 describes the LEDs on the single-port Ethernet card.
" # '# (
-$ 7
Left Yellow On—Traffic is flowing through the card.
Off—No traffic is present.
Right Green On—Link to the network is valid.
Off—No link to the network is present.
4 1&21&&! !
The quad-port Ethernet card has four connectors for four channels, with the top con- nector assigned to the first channel. Each connector has a corresponding yellow and green LED.
The four LEDs at the top are for the first and second channel. The four LEDs at the bottom are for the third and fourth channel, as shown in Figure 3-5.
Single-port Ethernet card


)'# < #
Table 3-5 describes the pair of yellow and green LEDs for a single channel.
)< # '# (
-$ 7
Yellow On—Traffic is flowing through the card.
Off—No traffic is present.
Green On—The link to the network is valid.
Off—No link to the network is present.
Troubleshooting the Filer Hardware 3-7
Quad-port Ethernet card · First or Third · Second or Fourth

The GB Ethernet card has one fibre-optic connector and two LEDs, as shown in Figure 3-6.

,'# = #
,= # +'# (
-$ 7
Yellow On—The network is active
Off—The network is not active
Link status Green On—The link is operating properly
Off—The link has failed
The filer has a single-port, wide differential SCSI adapter for tape backup on the back panel. This adapter has no LEDS.
GB Ethernet card · Network activity

The system reports its status, error, and diagnostic messages on the LCD and system console.
Most LCD messages are truncated versions of console messages that provide more information about the error condition than the LCD messages.
Table 3-7 lists the four types of LCD messages:
.1( ':
$ $
Startup messages Indicate the results of the POSTs (power-on self-tests) and the status of the boot process.
Error messages at startup Appear when the system is starting.
Informational or error messages
Appear when the system is operating.
Error messages when halting Show the system has halted or is restarting because of system problems.
This section identifies and describes the different types of messages on the LCD and suggests corrective actions for problems associated with the message.
Some of the corrective actions require you to contact a service technician to replace hardware components.
The system console messages are logged to /etc/messages. If you contact Dell tech- nical support for service, report both the LCD and the console message.
When the system is powered on, it verifies the hardware, loads the operating system, and displays the startup messages on the LCD and console, if the console is connected.
5 #6 *
If you are starting the system from a system boot diskette, the system does not dis- play the system prompt after it is started. Instead, it asks you for input. The LCD displays the following message: Waiting for user input.
For more information about starting the system boot diskette, refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide .
Troubleshooting the Filer Hardware 3-9

* ) 7 #
Table 3-8 lists the two types of startup messages.
01( (:
34 4
POST messages Immediately after you power on the filer.
Boot messages When the filer is loading the operating system.
When you turn on the power, the filer checks the hardware on the system board by running a series of POST tests from a PROM (Programmable Read-Only Memory).
The following list is a sample of messages that appear on the system console when the POST tests are running. The exact messages that appear on your system console depend on your system configuration.
Alpha Open Firmware by FirmWorks
Copyright 1995-1998 FirmWorks, Network Appliance. All Rights Reserved.
Firmware release 2.0_a2
Memory size is 512 MB
Finding image...
If you do not have a system console connected to the filer, you can observe the POST messages on the LCD.

3 7 #
The following list is a sample of POST messages that appear on the LCD:
3 !7 #
The following list gives the possible error messages on the LCD if the filer encounters errors during the POST tests.
If this error message appears, contact Dell technical support. The ok> prompt accepts debugging commands, which are reserved for authorized service personnel only.
*SIO error *FLPY seek err
*Watchdog failed*FLPY track err
*L2 parity error*FLPY head err
*Fan(s) stopped*FLPY format err
*CPU fan stopped*FLPY read error
*Overtemp alert*FLPY setup err
*PS #1 failed*LCD won't open
*PS #2 failed*LCD cmd stall
*No power info!*LCD cursor err
*Clock bogus. Date reset*LCD data error
*Env-A stat err*Clock error
*Env-B stat err*Clock dead
*Env-C stat err*Clock reset
Troubleshooting the Filer Hardware 3-11

If the hardware passes all POST tests, the filer begins to load the filer software and display informational boot messages.
Figure 3-7 shows a sample message that appears on the system console when the filer is successfully started. The exact boot messages that appear on your system console depend on your system configuration.
If you are starting the system from a system boot diskette, some messages might be different from the following messages. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for information about how the filer is started from a system boot diskette.
Version 1.12 Host Loop Id 119 Cacheline size 8 FC Packet size 2048 3 Disks: 25.8GB 1 shelf with DISK ENCLOSURE SCSI Host Adapter 0b slot 0: Ethernet Controller e0
Please enter the new hostname [ ]:
. :

Table 3-9 lists LCD error messages that the system detects when starting.
; (# :
- $
Add at least xMB more memory x—The amount of memory you need to add to the system. The system has too lit- tle memory for the amount of disk space installed.
Cannot initialize labels When it tries to create a new file system, the system cannot initialize the disk labels.
Cannot read labels This error occurs only when the filer tries to initialize a new file system. The mes- sage indicates that the filer has a problem reading disk labels it wrote to the disks.
This error occurs because
The system fails to read the size of a disk. The written disk labels were not valid.
Can’t open /etc/rc The /etc/rc file is corrupted. Run setup by entering setup at the hostname> prompt.
The setup program prompts you to enter the necessary system configuration infor- mation. For more information about the filer setup program, refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide.
Dirty shutdown in degraded mode
The file system might be inconsistent because you did not shut down the sys- tem cleanly when it was in degraded mode.
Configuration exceeds max PCI space
Memory space for mapping in PCI cards has been exhausted.
Make sure that all expansion cards in the filer are supported cards.
Disk labels scrambled! The disk labels are corrupted.
Troubleshooting the Filer Hardware 3-13

; (# :
- $
Drive m.n not supported m—The disk number; n—the disk ID num- ber. The system detects a disk or tape drive that is not supported by Dell.
EMU rev x not qualified The EMU revision level is not recognized.
Drive placement ha x shelf y ha—host adapter, x— host adapter num- ber, y—disk shelf number (PowerVault 700 storage enclosure address number). The specified drives are incorrectly placed in the PowerVault 700N storage system. For more information, refer to the manual for the PowerVault 700N storage system.
EMU y not supported The EMU firmware revision or part num- ber is not valid.
File system may be scrambled One of the following errors causes the file system to be inconsistent:
An unclean shutdown when the filer is in degraded mode and when NVRAM is not working. The number of disks detected in the disk array is different from the num- ber of disks recorded in the disk labels. The system cannot start when more than one disk is missing. The system encounters a read error while reconstructing parity. A disk failed at the same time as the system crashed.
Invalid PCI card slot n n—The card’s expansion slot number. The system detects an expansion card that is not supported by Dell.

; (# :
- $
No disks! The system can detect FC-AL controllers but not the disks. Verify that
All disks are installed properly in the PowerVault 700N storage system. If multiple PowerVault 700N storage systems are connected in a loop, ensure that a terminator is installed on the last PowerVault 700N storage system. Also ensure that all FC-AL connections are secure.
If the problem persists, use another FC-AL cable, then power-cycle (turn the power off, then on again) the PowerVault 700N storage system and the FC-AL adapter card.
No /etc/rc, running setup The system cannot find the /etc/rc file. It automatically starts setup and prompts you to enter the necessary system config- uration information. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for more information about filer setup.
No network interfaces! The system cannot detect any network interfaces. Turn off the system and verify that all network cards are seated properly in the appropriate expansion slots.
No NVRAM present The system cannot detect the NVRAM card. Make sure that the NVRAM card is securely installed in expansion slot 9.
No FC-AL or SCSI disk controllers!
The system cannot detect any FC-AL or SCSI controllers. Turn off the power on the filer and verify that all network cards are in their proper expansion slots.
No SES on shelf x ha y ha—host adapter. Occurs if the Enclosure Services in the FC-AL drive racks have not initialized or have problems.
NVRAM #n downrev! n—The serial number of the NVRAM card. The NVRAM card is an early revision that cannot be used with the system.
Troubleshooting the Filer Hardware 3-15

; (# :
- $
NVRAM test failed The system NVRAM produces an error when the system is starting.
Replace NVRAM batteries! The system is in degraded mode and both batteries on the NVRAM card are low or discharged. Replace both batteries immediately.
Unsupported NVRAM size xMB x—The amount of memory on the NVRAM card. The specified size is not supported.
Unsupported SES shelf x, ha y ha—host adapter. The system detects unsupported Enclosure Services hardware.
After the system has started, the LCD displays a number followed by a bar graph to indicate how many operations per second the system has processed.
If the system is not operating correctly, the LCD displays one of the following mes- sages. Some of the errors described also cause the service LED on the system front panel to illuminate.

/% - # :
- $
CIFS service disabled! This message appears only if you have licensed CIFS. One of the following errors causes CIFS service to fail:
The filer’s /etc/passwd and /etc/group files are missing. To learn how to cre- ate a new filer, refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide. The filer failed to register its WINS host name and workgroup name with the WINS server. Using the cifs setup command, enter the host name and workgroup name. The WINS server has a problem. Refer to the documentation for your WINS server for information about troubleshooting the server.
Data disk n x% rebuilt n—The RAID group disk number; x— amount of data reconstruction completed. This shows how much data reconstruction has been completed on the spare disk after the system entered degraded mode. If an error occurs when the reconstruction is in progress, the error message over- rides this message.
Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for informa- tion about how to locate a disk based on the RAID group disk number.
Disk n is broken n—The RAID group disk number. The solution depends on whether you have a hot spare installed in the system. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for informa- tion about how to locate a disk based on the RAID group disk number and how to replace a faulty disk.
Troubleshooting the Filer Hardware 3-17

/% - # :
- $
Fans stopped; replace them! This message appears if the fan assembly of the filer stops functioning. Replace the fan assembly as soon as possible.
Fault on shelf n n—The PowerVault 700N storage system enclosure address number. This message appears when the system detects an error on one or more Dell PowerVault 700N storage systems. Check the LEDs of the specified Dell PowerVault 700N storage systems to see whether a fan or power supply needs to be replaced. Replace the faulty fan or power supply on the Dell Power-Vault 700N storage system, if needed.
Maintenance mode The system is running in maintenance mode. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for more information about maintenance mode.
Non Maskable interrupt This message is usually generated by a correctable (nonfatal) memory error, but might signal other conditions.
If this message appears repeatedly, it might indicate a defective memory mod- ule (DIMM). Refer to the console messages or to the /etc/messages file for detailed information.
NFS service not enabled This message appears only if you have licensed NFS. NFS service has been dis- abled either because the system failed to enable it when it started, or because you disabled it with the nfs off command.
Parity disk is broken The parity disk is not operating and the system is in degraded mode. The solution depends on whether a hot spare is installed in the system. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for information about replacing a faulty disk.

/% - # :
- $
Parity disk x% rebuilt The system shows the amount of com- pleted data reconstruction on the spare disk after the system entered degraded mode.
x—Amount of data reconstructed. If an error occurs during reconstruction, the error message overrides this message.
Power supply degraded! One of the power supply units is down.
For more information about this error message, check the messages on the console. The power supply unit (1 or 2) generating the alarm is identified on the console message.
Replace NVRAM batteries! This message appears in these situations:
An NVRAM card battery is low or dis- charged. Replace both batteries as soon as possible. Both batteries on the NVRAM card are low or discharged. The system will shut down every 24 hours to encourage you to replace the batter- ies as soon as possible. To set the time that the system runs before it automatically shuts down, use the raid.timeout option with the options command. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for more information. Both NVRAM card batteries are low or discharged and the system is in degraded mode. The system shuts down immediately.
Troubleshooting the Filer Hardware 3-19

/% - # :
- $
Reporting SNMP traps and Set- ting up SNMP trap host
These messages appear briefly when the filer is reporting to the SNMP manage- ment host on SNMP trap conditions. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for informa- tion about SNMP administration and setting up SNMP management parameters.
Setting time from remote host This message appears briefly when the filer is resetting its Time-of-Day Clock from a remote time source. For more informa- tion, see the rdate command in the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide.
These messages appear briefly when the routing software is configuring the routing table. For more information, refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide.
x route to y
The following SES error messages might also appear during system operation: Drive placement ha x shelf y, No SES on shelf x ha y, Unsupported SES shelf x, ha y.
x default route

If a system problem has caused the system to halt or restart, the LCD displays one of the system halt messages listed in Table 3-11.
1 -3 # :
- $
CPU fan has failed The filer’s CPU fan has stopped function- ing. The system automatically shuts down.
Dumping core The system is dumping core after a sys- tem crash.
For information about core files, refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Ref- erence Guide .
Disk hung during swap! A disk error occurred as you were hot swapping a disk. To recover, disconnect the Dell PowerVault 700N storage system from the power supply and wait 15 sec- onds to allow all disks to spin down. Reconnect the power source to the Dell PowerVault 700N storage system and enter boot to restart the system.
Error dumping core The system cannot dump core during a system crash; the system restarts without dumping core.
Halted This message appears after you enter a halt command or after the system is halted automatically because of a prob- lem. If an error message appears during the restart, follow the instructions sug- gested in this chapter to fix the problem.
ISA IOCHK ISA bus failure.
Panicking The system is crashing. If the system does not hang while crashing, the mes- sage, Dumping core, appears.
Rebooting The system is restarting. The boot mes- sages follow.
Replace NVRAM batteries! Both NVRAM batteries are discharged. The system automatically shuts down.
Troubleshooting the Filer Hardware 3-21

1 -3 # :
- $
System error: errsts%x %x—An error code representing a spe- cific error condition. The system detects a hardware error, such as a parity error, that cannot be corrected. To clear the error condition, the system restarts.
System too hot The temperature sensor indicates that the system temperature is too high.
Uncor proc mchk: code x Processor machine check code.
Uncor sys mchk: code x System machine check code.

This chapter describes the tools Dell provides to help you when you have a problem with your PowerVault 720N, 740N, or 760N filer. It also tells you when and how to call Dell for technical or customer assistance.
If you need assistance with a technical problem, perform the following steps:
For more information, refer to “World Wide Web on the Internet” found later in this chapter.
When prompted by Dell’s automated telephone system, enter your Express Ser- vice Code to route the call directly to the proper support personnel. If you do not have an Express Service Code, open the Dell Accessories folder, double-click the Express Service Code icon, and follow the directions.
For instructions on using the technical support service, refer to “Technical Sup- port Service” and “Before You Call” found later in this chapter.
Getting Help 4-1

Dell provides a number of tools to assist you. These tools are described in the follow- ing sections.
The Internet is your most powerful tool for obtaining information about your filer and other Dell products. Through the Internet, you can access most of the services described in this chapter, including AutoTech, TechFax, order status, technical support, and product information.
From Dell’s World Wide Web home page (http://www.dell.com), click the Support icon, and click Support Your Dell. Enter your service tag number (or, if you have one, your Express Service Code) and click Submit. If you don’t have your service tag or Express Service Code available, you can also select support information by system.
Everything you need to know about your system is presented on the system support page, including the following tools and information:
Technical information — Details on every aspect of your system, including hard- ware specifications. Self-diagnostic tool — A system-specific troubleshooting application for resolving many computer-related issues by following interactive flowcharts. Drivers, files, and utilities — The latest drivers and BIOS updates to keep your system functioning at its best. Component support — Technical information, documentation, and troubleshoot- ing tips for different system components. Online Communications Center — Tool for submitting requests for both technical and non-technical information on Dell products. Avoid telephone delays by receiv- ing an e-mail response to your request for information if your filer is not functioning properly or if you have questions regarding your filer’s hardware or operation.
Dell can be accessed electronically using the following addresses:
http://www.dell.com/intl/apcc/ (for Asian/Pacific countries only)
http://www.euro.dell.com (for Europe only)
ftp.dell.com/
Log in as user: anonymous, and use your e-mail address as your password.

support@us.dell.com
apsupport@dell.com (for Asian/Pacific countries only)
support.euro.dell.com (for Europe only)
sales@dell.com
apmarketing@dell.com (for Asian/Pacific countries only)
info@dell.com
Dell’s automated technical support service—AutoTech—provides recorded answers to the questions most frequently asked by Dell customers.
When you call AutoTech, you use your touch-tone telephone to select the subjects that correspond to your questions. You can even interrupt an AutoTech session and continue the session later. The code number that the AutoTech service gives you allows you to continue your session where you ended it.
The AutoTech service is available 24 hours a day, seven days a week. You can also access this service through the technical support service. For the telephone number to call, refer to “Dell Contact Numbers” found later in this chapter.
Dell takes full advantage of fax technology to serve you better. Twenty-four hours a day, seven days a week, you can call the Dell TechFax line toll-free for all kinds of tech- nical information.
Using a touch-tone phone, you can select from a full directory of topics. The technical information you request is sent within minutes to the fax number you designate. For the TechFax telephone number to call, refer to “Dell Contact Numbers” found later in this chapter.
Use your modem to access Dell’s TechConnect bulletin board service (BBS) 24 hours a day, seven days a week. The service is menu-driven and fully interactive. The proto- col parameters for the BBS are 1200 to 19.2K baud, 8 data bits, no parity, 1 stop bit.
Getting Help 4-3

You can call this automated service to check on the status of any Dell products that you have ordered. A recording prompts you for the information needed to locate and report on your order. For the telephone number to call, refer to “Dell Contact Num- bers” found later in this chapter.
Dell’s industry-leading hardware technical-support service is available 24 hours a day, seven days a week, to answer your questions about Dell hardware.
Our technical support staff pride themselves on their track record: more than 90 per- cent of all problems and questions are taken care of in just one toll-free call, usually in less than 10 minutes. When you call, our experts can refer to records kept on your Dell system to better understand your particular question. Our technical support staff use computer-based diagnostics to provide fast, accurate answers to questions.
To contact Dell’s technical support service, first refer to the section titled “Before You Call” and then call the number for your country as listed in “Dell Contact Numbers” found later in this chapter.
If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact Dell Computer Corporation for customer assistance. Have your invoice or packing slip handy when you call. For the telephone number to call, refer to “Dell Contact Numbers” found later in this chapter.
If you need information about additional products available from Dell Computer Corpo- ration, or if you would like to place an order, visit Dell’s World Wide Web site at http://www.dell.com/. For the telephone number to call to speak to a sales special- ist, refer to “Dell Contact Numbers” found later in this chapter.
Prepare all items being returned, whether for repair or credit, as follows:
For the telephone number to call, refer to “Dell Contact Numbers” found later in this chapter.

You are responsible for paying shipping expenses. You are also responsible for insuring any product returned, and you assume the risk of loss during shipment to Dell Computer Corporation. Collect-on-delivery (C.O.D.) packages are not accepted.
Returns that are missing any of the preceding requirements will be refused at our receiving dock and returned to you.
Remember to fill out the Diagnostics Checklist (Figure 4-1). If possible, turn on your system before you call Dell for technical assistance and call from a telephone at or near the filer’s console. You may be asked to type some commands at the keyboard, relay detailed information during operations, or try other troubleshooting steps possi- ble only at the filer’s console. Make sure the system documentation is available.
!"# % ' ) %
Getting Help 4-5

Service tag (bar code on the back of the computer):
Return Material Authorization Number (if provided by Dell support technician):
Expansion cards:
Are you connected to a network? yes no
Refer to your operating system documentation to determine the contents of the system’s start-up files. If the computer is connected to a printer, print each file. Otherwise, record the contents of each file before calling Dell.
Error message, beep code, or diagnostic code:
Description of problem and troubleshooting procedures you performed:
" !

When you need to contact Dell, use the telephone numbers, codes, and electronic addresses provided in Tables 4-2 and 4-3. Table 4-2 provides the various codes required to make long-distance and international calls. Table 4-3 provides local tele- phone numbers, area codes, toll-free numbers, Web site and e-mail addresses, if applicable, for each department or service available in various countries around the world. If you are making a direct-dialed call to a location outside of your local tele- phone service area, determine which codes to use (if any) in Table 4-2 in addition to the local numbers provided in Table 4-3. For example, to place an international call from Paris, France to Bracknell, England, dial the international access code for France followed by the country code for the U.K., the city code for Bracknell, and then the local number as shown in the following illustration.

To place a long-distance call within your own country, use area codes instead of inter- national access codes, country codes, and city codes. For example, to call Paris, France from Montpellier, France, dial the area code plus the local number as shown in the following illustration.
01 Area Code (for Paris from
The codes required depend on where you are calling from as well as the destination of your call; in addition, each country has a different dialing protocol. If you need assis- tance in determining which codes to use, contact a local or an international operator.

7
Australia (Sydney) 0011 61 2
Austria (Vienna) 900 43 1
Belgium (Brussels) 00 32 2
Brunei — 673 —
Canada (North York, Ontario) 011 — Not required
Chile (Santiago) — 56 2
China (Xiamen) — 86 592
Czech Republic (Prague) 00 420 2
Denmark (Horsholm) 009 45 Not required
Finland (Helsinki) 990 358 9
France (Paris) (Montpellier) 00 33 (1) (4)
Germany (Langen) 00 49 6103
Hong Kong 001 852 Not required
Ireland (Bray) 16 353 1
Italy (Milan) 00 39 2
Japan (Kawasaki) 001 81 44
Korea (Seoul) 001 82 2
Luxembourg 00 352 —
Macau — 853 Not required
Malaysia (Penang) 00 60 4
Mexico (Colonia Granada) 95 52 5
Netherlands (Amsterdam) 00 31 20
New Zealand 00 64 —
Norway (Lysaker) 095 47 Not required
Poland (Warsaw) 011 48 22
Singapore (Singapore) 005 65 Not required
South Africa (Johannesburg) 09/091 27 11
Spain (Madrid) 07 34 91
8 9

7
Sweden (Upplands Vasby) 009 46 8
Switzerland (Geneva) 00 41 22
Taiwan 002 886 —
Thailand 001 66 —
U.K. (Bracknell) 010 44 1344
U.S.A. (Austin, Texas) 011 1 Not required
$
Customer Technical Support (Dell Dimension™ systems only) 1-300-65-55-33
Customer Technical Support (Other systems) toll free: 1-800-633-559
Customer Care toll free: 1-800-819-339
Corporate Sales toll free: 1-800-808-385
Transaction Sales toll free: 1-800-808-312
Fax toll free: 1-800-818-341
Technical Support 0660-8779
Customer Care 01 660 8056
Switchboard 01 491 04 0
Customer Technical Support 02 481 92 88
Customer Care 02 481 9119
Home/Small Business Sales toll free: 0800 16884
Corporate Sales 02 481 91 00
Fax 02 481 92 99
Switchboard 02 481 91 00
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
Customer Technical Support (Penang, Malaysia) 810 4966
Customer Service (Penang, Malaysia) 810 4949
Transaction Sales (Penang, Malaysia) 810 4955
Canada (North York, Ontario)
Automated Order-Status System toll free: 1-800-433-9014
AutoTech (Automated technical support) toll free: 1-800-247-9362
Customer Care (From outside Toronto) toll free: 1-800-387-5759
Customer Care (From within Toronto) 416 758-2400
Customer Technical Support toll free: 1-800-847-4096
Sales (Direct Sales—from outside Toronto) toll free: 1-800-387-5752
Sales (Direct Sales—from within Toronto) 416 758-2200
Sales (Federal government, education, and medical) toll free: 1-800-567-7542
Sales (Major Accounts) toll free: 1-800-387-5755
TechConnect BBS (Austin, Texas, U.S.A.) 512 728-8528
TechFax toll free: 1-800-950-1329
Sales, Customer Support, and Technical Support toll free: 1230-020-4823
Customer Service toll free: 800 858 2437
Sales toll free: 800 858 2222
Czech Republic* (Prague)
Technical Support 02 22 83 27 27
Customer Care 02 22 83 27 11
Fax 02 22 83 27 14
TechFax 02 22 83 27 28
Switchboard 02 22 83 27 11
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
Technical Support 45170182
Customer Care 45170181
Switchboard 45170100
Fax Technical Support (Upplands Vasby, Sweden) 859005594
Fax Switchboard 45170117
Technical Support 09 253 313 60
Customer Care 09 253 313 61
Fax 09 253 313 99
Switchboard 09 253 313 00
Technical Support (Paris) 01 47 62 68 90
Technical Support (Montpellier) 04 67 06 62 86
Customer Care (Paris) 01 47 62 68 92
Customer Care (Montpellier) 04 67 06 61 96
TechConnect BBS (Montpellier) 04 67 22 53 04
Fax (Montpellier) 04 67 06 60 07
Switchboard (Paris) 01 47 62 69 00
Switchboard (Montpellier) 04 67 06 60 00
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
Technical Support 06103 971-200
Technical Support Fax 06103 971-222
Preferred Accounts Customer Care 06103 971-420
Preferred Accounts Customer Care Fax 06103 971-544
Customer Care 06103 971-500
TechConnect BBS 06103 971-666
Switchboard 06103 971-0
Technical Support toll free: 800 96 4107
Customer Service (Penang, Malaysia) 810 4949
Transaction Sales toll free: 800 96 4109
Corporate Sales toll free: 800 96 4108
Customer Technical Support 1-850-543-543
Customer Care 01 204 4026
Home/Small Business Customer Care (Bracknell, U.K.) 0870 906 0100
Sales 1-850-235-235
SalesFax 01 286 2020
Fax 01 286 6848
TechConnect BBS 01 204 4711
TechFax 01 204 4708
Switchboard 01 286 0500
Technical Support 2 57782.690
Customer Care 2 57782.555
Sales 2 57782.411
Fax 2 57503530
Switchboard 2 57782.1
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
Technical Support toll free: 0088-22-7890
Technical Support (Server) toll free: 0120-1984-35
Technical Support (Dimension and Inspiron™) toll free: 0120-1982-56
Technical Support (WorkStation, OptiPlex™, and Latitude™) toll free: 0120-1984-39
Y2K Support 044 556-4298
Customer Care 044 556-4240
Direct Sales 044 556-3344
Commercial Sales 044 556-3430
Faxbox Service 03-5972-5840
Switchboard 044 556-4300
Technical Support toll free: 080-200-3800
Transaction Sales toll free: 080-200-3600
Corporate Sales toll free: 080-200-3900
Customer Service (Penang, Malaysia) 810 4949
Fax 394 3122
Switchboard 287 5600
Customer Technical Support (Austin, Texas, U.S.A.) 512 728-4093
Customer Service (Austin, Texas, U.S.A.) 512 728-3619
Fax (Technical Support and Customer Service) (Austin, Texas, U.S.A.) 512 728-3883
Sales (Austin, Texas, U.S.A.) 512 728-4397
SalesFax (Austin, Texas, U.S.A.) 512 728-4600

$
Customer Technical Support (Brussels, Belgium) . . 02 481 92 88
Home/Small Business Sales (Brussels, Belgium) toll free: 080016884
Corporate Sales (Brussels, Belgium) 02 481 91 00
Customer Care (Brussels, Belgium) 02 481 9119
Fax (Brussels, Belgium) 02 481 92 99
Switchboard (Brussels, Belgium) 02 481 91 00
Technical Support toll free: 0800 582
Customer Service (Penang, Malaysia) 810 4949
Transaction Sales toll free: 0800 581
Technical Support toll free: 1 800 888 298
Customer Service 04 810 4949
Transaction Sales toll free: 1 800 888 202
Corporate Sales toll free: 1 800 888 213
Automated Order-Status System (Austin, Texas, U.S.A.) 512 728-0685
AutoTech (Automated technical support) (Austin, Texas, U.S.A.) 512 728-0686
Customer Technical Support 525 228-7870
Sales 525 228-7811
Customer Service 525 228-7878
Main 525 228-7800
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
Customer Technical Support 020 5818838
Home/Small Business Sales toll free: 0800-0663
Home/Small Business SalesFax 020 682 7171
Corporate Sales 020 581 8818
Corporate SalesFax 020 686 8003
Fax 020 686 8003
Switchboard 020 581 8818
New Zealand Technical Support (Dell Dimension systems only) ($2.50 + GST per call) 0900 51010
Technical Support (Other systems) 0800 446 255
Customer Service 0800 444 617
Sales 0800 441 567
Fax 0800 441 566
Technical Support 67116882
Customer Care 67116881
Switchboard 67116800
Fax Technical Support (Upplands Vasby, Sweden) 590 05 594
Fax Switchboard 67116865
Technical Support 22 60 61 99
Customer Care 22 60 61 99
Sales 22 60 61 99
Fax 22 60 61 998
Switchboard 22 60 61 999
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
Technical Support toll free: 800 6011 051
Customer Service (Penang, Malaysia) 04 810 4949
Transaction Sales toll free: 800 6011 054
Corporate Sales toll free: 800 6011 053
Technical Support 011 709 7710
Customer Care 011 709 7710
Sales 011 706 7700
Fax 011 709 0495
Switchboard 011 709 7700
Southeast Asian/ Pacific Countries (excluding Australia, Brunei, China, Hong Kong, Japan, Korea, Macau, Malaysia, New Zealand, Singapore, Taiwan, and Thailand—refer to individual listings for these countries)
Customer Technical Support, Customer Service, and Sales (Penang, Malaysia) 60 4 810-4810
Technical Support 902 100 130
Corporate Customer Care 902 118 546
Home/Small Business Customer Care 902 118 540
TechConnect BBS 91 329 33 53
Corporate Sales 902 100 185
Home/Small Business Sales 902 118 541
Switchboard 91 722 92 00
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
Sweden* (Upplands Vasby)
Technical Support 08 590 05 199
Customer Care 08 590 05 169
Fax Technical Support 08 590 05 594
Sales 08 590 05 185
Technical Support 0844 811 411
Customer Care 0848 802 802
Fax 022 799 01 90
Switchboard 022 799 01 01
Technical Support toll free: 0080 651 226/0800 33 557
Customer Service (Penang, Malaysia) 810 4949
Transaction Sales toll free: 0080 651 228/0800 33 556
Corporate Sales toll free: 0080 651 227/0800 33 555
Technical Support toll free: 0880 060 07
Customer Service (Penang, Malaysia) 810 4949
Sales toll free: 0880 060 06
U.K.* (Bracknell)
Technical Support Department 0870-908-0800
Corporate Customer Care 01344 720206
Home/Small Business Customer Care 0870-906-0010
TechConnect BBS 0870-908-0610
Sales 01344 720000
AutoFax 0870-908-0510
* For technical assistance in this country after normal working hours, use one of the following numbers: (353-1) 204 4008 or (353-1) 286 5908 (English only—the call is rerouted to the U.S.A.).

$
U.S.A. (Austin, Texas)
Automated Order-Status System toll free: 1-800-433-9014
AutoTech (Automated technical support) toll free: 1-800-247-9362
Dell Home and Small Business Group:
Customer Technical Support (Return Material Authorization Numbers) toll free: 1-800-624-9896
Customer Service (Credit Return Authorization Numbers) toll free: 1-800-624-9897
National Accounts (systems purchased by established Dell national accounts [have your account number handy], medical institutions, or value-added resellers [VARs]):
Customer Service and Technical Support (Return Material Authorization Numbers) toll free: 1-800-822-8965
Public Americas International (systems purchased by governmental agencies [local, state, or federal] or educational institutions):
Customer Service and Technical Support (Return Material Authorization Numbers) toll free: 1-800-234-1490
Dell Sales toll free: 1-800-289-3355
Spare Parts Sales toll free: 1-800-357-3355
DellWareSM toll free: 1-800-753-7201
DellWare FaxBack Service 512 728-1681
Fee-Based Technical Support toll free: 1-800-433-9005
Sales (Catalogs) toll free: 1-800-426-5150
Fax toll free: 1-800-727-8320
TechFax toll free: 1-800-950-1329
TechConnect BBS 512 728-8528
Dell Services for the Deaf, Hard-of- Hearing, or Speech-Impaired toll free: 1-877-DELLTTY (1-877-335-5889)
Switchboard 512 338-4400
8 9

connecting a terminal, 2-19 DB-9–to–DB-9 serial cable, 2-18 pin settings, 2-18
electrostatic discharge (ESD) wrist strap
and grounding leash, 2-3
CPU fan has failed message, 3-21
CPU fan stopped message, 3-11
electrostatic discharge. See ESD
EMU rev x not qualified message, 3-14
EMU y firmware y not supported
Env-A/B/C rupt err message, 3-11
Data disk n x% rebuilt message, 3-17
Data ONTAP, filer software, 1-9
Env-A/B/C stat err message, 3-11
Environmental Monitoring Unit (EMU)
environmental requirements, 2-2, 2-3
Data disk x% rebuilt message, 3-17 Dirty shutdown in degraded mode
Error dumping core message, 3-21
message, 3-13 Parity disk is broken message, 3-18 Parity diskx% rebuilt message, 3-19 Power supply degraded! message,
error messages at startup
Add at least xMB more memory, 3-13 Can’t open /etc/rc, 3-13 Cannot initialize labels, 3-13 Cannot read labels, 3-13 Configuration exceeds max PCI space,
3-19 Replace NVRAM batteries! message,
3-13 Dirty shutdown in degraded mode,
3-13 Disk labels scrambled!, 3-13 Drive m.n not supported, 3-14 Drive placement ha x shelf y, 3-14 EMU rev x not qualified, 3-14 EMU y firmware y not supported, 3-14 File system may be scrambled, 3-14 Invalid PCI card slot n, 3-14 No /etc/rc, running setup, 3-15 No disks!, 3-15 No FC-AL or SCSI disk controllers!,
Dirty shutdown in degraded mode
Disk hung during swap! message, 3-21
Disk labels scrambled! message, 3-13
Disk n is broken message, 3-17
disk storage limits, 1-6
see system boot diskette
3-15 No network interfaces!, 3-15 No NVRAM present, 3-15 No SES on shelf x ha y, 3-15 NVRAM #n downrev!, 3-15 NVRAM test failed, 3-16 Replace NVRAM batteries, 3-16 Unsupported NVRAM size xMB, 3-16 Unsupported SES shelf x, ha y, 3-16
Drive m.n not supported message, 3-14
Drive placement ha x shelf y message,
Dumping core message, 3-21

error messages when halting
Fault on shelf n message, 3-18
CPU fan has failed, 3-21 Disk hung during swap!, 3-21 Error dumping core, 3-21 Halted, 3-21 ISA IOCHK, 3-21 Panicking, 3-21
see Fibre Channel Arbitrated Loop
back panel, 1-4 behind front panel, 1-3 front panel, 1-2
error or informational messages
fiber cable, GB Ethernet, 2-16
CIFS service disabled!, 3-16 Data disk n x% rebuilt, 3-17 disk n is broken, 3-17 Fans stopped; replace them!, 3-18 Fault on shelf n, 3-18 maintenance mode, 3-18 NFS service not enabled, 3-18 Non Maskable interrupt, 3-18 Parity disk is broken, 3-18 Parity disk x% rebuilt, 3-19 Power supply degraded, 3-19 Replace NVRAM batteries!, 3-19 Reporting SNMP traps, 3-20 Setting time from remote host, 3-20 Setting up SNMP trap host, 3-20 x default route, 3-20 x route to y, 3-20
Fibre Channel Arbitrated Loop (FC-AL)
adapter, 1-6, 2-13 adapter slot assignments, 1-8 disk array enclosure (DAE), 1-6 filer-to-disk storage cable, 2-12, 2-13 filer-to-shelf cable, 2-11 interface, 1-5, 2-16 interface with PowerVault F700N DAE
with 18-GB FC-AL disk drives, 1-5
File system may be scrambled message,
*FLPY format err message, 3-11 *FLPY head err message, 3-11 *FLPY init fail message, 3-12 *FLPY reg error message, 3-12 *FLPY seek err message, 3-11 *FLPY setup err message, 3-11 *FLPY track err message, 3-11
see electrostatic discharge wrist strap
available network connectivity, 1-4,
FP button stuck message, 3-12
2-15 built-in 10/100Base-T Ethernet
frequency, electrical requirements, 2-2
interface, 1-4 cabling requirements, 2-16 card LEDs, 3-5 connecting the filer, 2-16 types of cards, 2-16
GB Ethernet card, 1-5
cabling requirements, 2-16 LEDs, 3-8 slot assignments, 1-8
*CPU fan stopped message, 3-11 *Fans stopped message, 3-11 Fans stopped; replace them!
using wrist strap and grounding leash,

Light Emitting Diodes (LEDs), 1-2, 3-2
10/100Base-T Ethernet cards, 3-5, 3-6 activity LED on the front panel, 3-3 built-in Ethernet interface, 3-5 front panel, 3-2, 3-3 power LED on the front panel, 3-3 power supply, 3-3 quad-port 10/100Base-T Ethernet card,
halt command, 2-14, 3-21
height of filer, 2-3
AutoTech service, 4-3 Internet, 4-2 TechConnect BBS, 4-3 TechFax service, 4-3
3-6 status LED on the front panel, 3-3
Liquid Crystal Display (LCD), 1-3
Liquid Crystal Display (LCD) messages,
3-9 Data disk n x% rebuilt, 3-17 Disk hung during swap!, 3-21 Disk labels scramble!, 3-13 Disk n is broken, 3-17 Fault on shelf n, 3-18 Maintenance mode, 3-18 NFS service not enabled, 3-18 No FC-AL or SCSI disk controllers!,
see error and informational messages
installing the filer, 2-1, 2-8
3-15 Non Maskable interrupt, 3-18 Parity disk is broken, 3-18, 3-19 Parity disk x% rebuilt, 3-19 POST error messages, 3-11 Power supply degraded!, 3-19 Replace NVRAM batteries!, 3-19 Reporting SNMP traps, 3-20 Setting time from remote host, 3-20 Setting up SNMP trap host, 3-20 STDBY/SERV, 3-3 Unsupported NVRAM size xMB, 3-16 x default route, 3-20 x route to y, 3-20
connecting to a disk storage shelf, 2-11 connecting to a power source, 2-20 connecting to a tape backup device,
2-14 connecting to the network, 2-15 establishing a terminal connection,
2-18 in a rack, 2-4 preparing for the installation, 2-1
Internet help tools, 4-2
Invalid PCI card slot n message, 3-14
ISA IOCHK message, 3-21
L2 parity error message, 3-11
Maintenance mode message, 3-18
maximum current, for the filer, 2-2
see Liquid Crystal Display
see Light Emitting Diodes

Disk n is broken, 3-17 Drive m.n not supported, 3-14 Dumping core, 3-21 EMU rev x not qualified, 3-14 Error dumping core, 3-21 Fans stopped; replace them!, 3-18 File system may be scrambled, 3-14 Finding image..., 3-10 Firmware release 2.0_a2, 3-10 Halted, 3-21 Invalid PCI card slot n, 3-14 Maintenance mode, 3-18 Memory size is 512 MB, 3-10 NFS service not enabled, 3-18 No /etc/rc, running setup, 3-15 No disks!, 3-15 No FC-AL or SCSI disk controllers!,
*Clock bogus. Date reset, 3-11 *Clock dead, 3-11 *Clock error, 3-11 *Clock reset, 3-11 *CPU fan stopped, 3-11 *Env-A rupt err, 3-11 *Env-A stat err, 3-11 *Env-B rupt err, 3-12 *Env-B stat err, 3-11 *Env-C rupt err, 3-12 *Env-C stat err, 3-11 *Fans stopped, 3-11 *FLPY format err, 3-11 *FLPY head err, 3-11 *FLPY init fail, 3-12 *FLPY read error, 3-11 *FLPY reg error, 3-12 *FLPY seek err, 3-11 *FLPY track err, 3-11 *FP button stuck, 3-12 *L2 parity error, 3-11 *LCD cmd stall, 3-11 *LCD cursor err, 3-11 *LCD data error, 3-11 *LCD won’t open, 3-11 *No power infor!, 3-11 *Overtemp alert, 3-11 *PS #1 failed, 3-11 *PS #2 failed, 3-11 *SIO error, 3-11 *Watchdog failed, 3-11 Add at least xMB more memory, 3-13 Can’t open /etc/rc, 3-13 Cannot initialize labels, 3-13 Cannot read labels, 3-13 Checking sensors, 3-11 CIFs service disabled!, 3-17 Configuration exceeds max PCI space,
3-15 No network interfaces!, 3-15 No NVRAM present, 3-15 No SES on shelf x ha y, 3-15 Non Maskable interrupt, 3-18 NVRAM #n downrev, 3-15 NVRAM test failed, 3-16 Panicking, 3-21 Parity disk is broken, 3-18 Parity disk x% rebuilt, 3-19 Power supply degraded!, 3-19 Probing devices, 3-10, 3-11 Rebooting, 3-21 Replace NVRAM batteries!, 3-16, 3-19,
3-21 Reporting SNMP traps, 3-20 Setting time from remote host, 3-20 Setting up SNMP trap host, 3-20 Starting, 3-10 Startup failed, 3-11 System error:errsts%x, 3-22 System too hot, 3-22 Testing 256MB, 3-11 Testing 512MB, 3-10 Testing clock, 3-11 Testing floppy, 3-11 Testing LCD, 3-10 Testing SIO, 3-10 Testing watchdog, 3-11
3-13 CPU fan has failed, 3-21 Data disk n x% rebuilt, 3-17 Dirty shutdown in degraded mode,
3-13 Disk hung during swap!, 3-21 Disk labels scrambled!, 3-13
messages · Index 5

Uncor proc mchk: code x, 3-22 Unsupported NVRAM size xMB, 3-16 Unsupported SES shelf x, ha y, 3-14,
see Non-Volatile Random Access
3-16 x default route, 3-20 x route to y, 3-20
$
Overtemp alert message, 3-11
built-in 10/100Base-T Ethernet, 1-4 expansion slots, 1-6
Network Interface Cards (NICs), 2-15
Parity disk is broken message, 3-18, 3-19
connecting the filer to the network,
Parity disk x% rebuilt message, 3-19
nfs off command, 3-18
power LED on the front panel, 3-3
NFS service not enabled message, 3-18
connecting the filer, 2-20
see Network Interface Cards
hot-swappable, 1-4 redundant, 1-4
No /etc/rc, running setup message, 3-15
No disks! message, 3-15
Power supply degraded! message, 3-19
No FC-AL or SCSI disk controllers!
power-on self-test (POST) messages,
3-10, 3-11 error messages on the LCD, 3-11
No network interfaces! message, 3-15
No power info! message, 3-11
connecting to the filer, 2-11
No SES on shelf x ha y message, 3-15
Non-Volatile Random Access Memory
(NVRAM) card, 1-5 File system may be scrambled
help tools, 4-1 with your order, 4-4
message, 3-14 No NVRAM present message, 3-15 NVRAM #n downrev message, 3-15 NVRAM test failed message, 3-16 Replace NVRAM batteries! message,
PS #1/#2 failed message, 3-11
3-16, 3-21 Unsupported NVRAM size xMB
quad-port 10/100Base-T Ethernet card
null modem cable, for serial console, 2-18

slot assignments, 1-7, 1-8
Small Computer System Interface
rack, for installing the filer, 2-4
SNMP error messages, 3-20
Replace NVRAM batteries! message,
software on filer, Data ONTAP, 1-9
space and location requirement, 2-3
documentation, xiv electrical, 2-2 environmental, 2-3 rack installation, 2-3, 2-4
from the system boot diskette, 3-9
Reset button on the front panel, 1-3
status LED on the front panel, 3-3
robotic loader, on tape backup device,
POST error messages, 3-11, 3-12 starting the system, 3-9
for preventing ESD, xi health considerations, xi
logged in /etc/messages, 3-9
connecting disk shelves, 2-11 ID of tape backup, 2-14 ID of tape device, 2-14 tape backup device, 1-9, 2-14 tape backup interface, 1-4
tape backup device, 1-9
connecting the filer, 2-14 robotic loader, 2-14 SCSI ID, 2-14
DB-9–to–DB-9 straight-through, 2-18 pin settings, 2-18
serial concentrator, connecting to the
obtaining, 4-1 warranty repair or credit, 4-4
CONSOLE port, 1-5 for connecting the ASCII terminal, 2-19
technical specifications, 1-2, 1-3
environmental requirements, 2-2 System too hot message, 3-22
setup program, error message, 3-15
shipment package, contents, 2-3
terminal connection, to the filer, 2-18
SIO error message, 3-11

SCSI bus at the tape device, 2-14
terminology used in this manual, xiv
*CPU fan stopped message, 3-11 *Fans stopped message, 3-11 CPU fan has failed message, 3-21 Fans stopped; replace them message,
Diagnostics Checklist, 4-6 Internet tools, 4-2
troubleshooting, using LEDs and LCD
warranty repair or credit, 4-4
Watchdog failed message, 3-11
weight, of filer, 2-4
for Ethernet card, 2-16
World Wide Web help tools, 4-2