Dell PowerConnect 10G Switches:
M8024-k, 8024 and 8024F


Network Enabled Solutions Team, Kevin Locklear
Contributor
Kili Land

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind.
© 2011 - 2012 Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or photography. Dell, the Dell logo, PowerConnect and PowerEdge are trademarks of Dell Inc. Intel and Xeon are registered trademarks of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others.
March 2012| Rev 2.0



Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
The PowerConnect™ M8024-k, 8024 and 8024F switches are now DCB/DCBx capable with a downloadable update. Starting with firmware 4.2, the latest PowerConnect™ 10 Gigabit switches can now be used as an FCoE Transit Switch (FIP Snooping Bridge, T11, BB-5). With this new firmware implementation Converged Network Adapters (CNAs) can be used in the rack-mount or blade server to enable access to Fibre Channel networks and their storage.
capability and will not be supported for any of the described scenarios.
This document provides an easy to use guide for configuring FIP Snooping on the Dell PowerConnect™ M8024-k Blade Switch (Figure 1), and the PowerConnect™ 8024F (Figure 2).
Dell PowerConnect™ M8024-k Switch (10G Ethernet) Figure 1.

Dell PowerConnect™ 8024F (10G Ethernet) Figure 2.

With FIP snooping enabled on the PowerConnect™ 8024 model switches, FIP logins, solicitations, and advertisements are monitored. In this monitoring or snooping process the switch gathers information pertaining to the ENode and FCF addresses. With this information the switch will then place filters that only allow access to ENode devices that have logged-in successfully. This enables the FCoE VLAN to deny all other traffic except this lossless FCoE storage traffic.
The filtering process also secures the end-to-end path between the ENode device and the FCF. The ENode will only be able to talk with the FCF in which it has logged into.
With a switch configured to performing FIP snooping the industry term for this switch is FSB or FIP snooping bridge. It is performing FIP snooping as described in the previous term.
FCoE forwarders (FCFs) act as an Ethernet and FC switch combined. All typical termination functions that would occur on a FC switch occur on the FCF. FCF’s give VF_Ports and VE_Ports for their virtual FC interfaces.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Priority Flow Control (PFC), or Per-Priority Pause is defined in the IEEE 802.1Qbb standard. PFC is flow control based on priority settings and adds additional information to the standard pause frame. The additional fields added to the pause frame allow devices to pause traffic on a specific priority instead of pausing all traffic. (IEEE, 2009) Pause frames will be initiated by the FCF in most cases when its receive buffers are starting to reach a congested point. With PFC traffic is paused instead of dropped and retransmitted. This provides the lossless network behavior necessary for FC packets to be encapsulated and passed along the Ethernet paths.
N-port identifier virtualization which enables multiple N-port fabric logins at the same time on the same physical FC link (Cisco Systems, Inc., 2011).This term is in reference to the Cisco Nexus 5000 series switches implementation of NPIV.
N-port virtualizer is a FC aggregation method which passes traffic through to end devices, while eliminating the need to use a domain ID for this device (Cisco Systems, Inc., 2011). This term is also in reference to configuration settings on the Cisco Nexus 5000 series switches.
Virtual SAN is a logical partitioning of physical connections to provide for fabric or SAN separation.
each PowerConnect M8024-k module from a single serial connection to the chassis. For more information about console redirect, see the Dell Blade Server CMC User's Guide at http://support.dell.com/support/edocs/software/smdrac3/cmc/index.htm

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
The following sections will present very basic examples of deploying the 10G switches for FIP Snooping and will provide step-by-step explanations of the CLI commands as a guide. The GUI does not currently support configurations for FIP Snooping. Consult the table of contents above for a list of examples covered in this document.
General overview of deployment Figure 3.

The following suggested configurations used to deploy this solution is done in a sequential order for reading but as Figure 3 represents this is more of a simultaneous process. There are dependencies that will be occuring during the configuration that will rely on other parts of the process. Storage configuration is not covered in any depth due to the possibility for various supported storage devices as part of the whole solution.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Each of the following scenarios in this document assume that the PowerConnect™ 8024 model switch being used is in normal Switch Mode (not Simple Mode) and is using firmware version 4.2.x.x or later.
covered in this document. FCoE is not supported with the PowerConnect 8024 model switches in Simple Mode. The CLI command in the example may be used for disabling Simple Mode, but please consult the User Guide for more information on specifics of Simple Mode.
Disabling simple mode Figure 4.

configure no mode simple
If a Non-FIP-Aware switch is introduced anywhere in the data path FCoE will not be supported and can’t be expected to work as designed. The Dell PowerConnect M8024-k and 8024F are considered non- FIP-aware switches until they have the 4.2 or greater firmware installed. See updating firmware section for instructions on performing this update.
Stacking is not recommended in an FCoE environment with the Dell PowerConnect 8024 Model Switches. If the switches are stacked the configuration should be changed to disable stacking. Please refer to the Dell PowerConnect 8024 4.2 firmware user’s guide for further details on disabling or changing stacking ports. If the configuration is used in this manner lossless Ethernet and reliability can not be guaranteed.
As mentioned in the non-FIP-aware bullet the Dell PowerConnect Switches will not support FCoE or FIP snooping without 4.2 or greater firmware. See updating firmware section to perform this update.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Scenario 1: Deploying the Dell PowerConnect 8024 Series FSB in a Cisco 5000 Series Switch (NPIV) environment
This first example is a basic, single connection between devices example using the Dell PowerConnect M8024-k. This configuration is being shown for the purposes of simplification and potentially easing into the progression of a more in-depth setup. It is also easier to use a simple configuration such as this setup to aid in troubleshooting of the initial install. In a typical business environment most configurations will be scaled to include several connections between servers and storage. The scenarios following this one will show some of these larger configurations. Note that this configuration will also work in the rack server environment with Dell PowerConnect 8024F switch
Simple 1-link connection between devices Figure 5.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
The flowchart in Figure 8 is a general overview of how the deployment will occur. This includes the basic planning that will need to take place in order for most of the steps in the rest of the document to fall into place.
General Overview of the whole configuration and planning procedure Figure 6.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Figure 9 is a graphical representation of how many of the configuration pieces are considered parallel settings. Most of the configuration will depend heavily on configurations being completed in more than just one place.
Overview of parallel configuration Figure 7.

In many of the business environments where this configuration will be installed there will be different administrators for the different areas of the infrastructure. In other words there may be a LAN infrastructure administrator, a storage or SAN administrator, and potentially a server administrator. These different team members will have to work together for a successful deployment of all the involved parts. In an M1000e bladeserver environment it may be the server admin that deploys the blade servers, operatings systems, network adapter drivers, and very possibly configures the blade IOM networking switches. If different admins are involved as described these tasks can be done in parallel to enable a quicker deployment.
It is important to understand certain checks or validations along the way may rely on configurations being completed in a different part of the infrastructure.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
The Dell PowerConnect 8024 model switches will monitor FIP packets and will establish the proper filtering, and priorities for the FCoE traffic that is passed through the configured links. To see an example of the full configuration see Appendix-A - M8024-K Example.
Example commands for Dell PowerConnect M8024-k (can be copied and pasted) Figure 8.
configure no mode simple vlan database vlan 20,1000 exit hostname "mySwitch" vlan database vlan 20,1000 exit feature fip-snooping vlan 20,1000 fip-snooping enable exit interface out-of-band ip address 192.168.10.1 255.255.255.0 192.168.10.254 exit classofservice dot1p-mapping 1 1 classofservice dot1p-mapping 2 2 classofservice dot1p-mapping 3 3 classofservice dot1p-mapping 4 4 classofservice dot1p-mapping 5 5 classofservice dot1p-mapping 6 6 exit interface Te1/0/1 switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 switchport mode general lldp dcbx port-role auto-down spanning-tree portfast exit interface Te1/0/20 switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 spanning-tree cost 0 spanning-tree port-priority 0 switchport mode general lldp dcbx port-role auto-up fip-snooping port-mode fcf exit
several impacting steps so that the switch will retain the configuration settings put into place on the next boot.
Routed VLAN’s can’t have FIP-snooping enabled. VLAN 1 may be set for routing and this must be
changed in the VLAN database if it is going to be used as the native VLAN or PVID.
Command-Line Interface Method

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Step by Step explanation of CLI example o Configure – this brings the prompt into the configuration interface
o no mode simple – puts switch into normal mode o vlan database - moves down into the VLAN database interface
vlan 20 – add VLAN 20 to used for untagged traffic or as the native VLAN vlan 1000 - add VLAN 1000 to the VLAN database, this will be the FCoE VLAN exit – exit the current level of the interface configuration o hostname “mySwitch” – set the hostname of the switch in this example “mySwitch” o feature fip-snooping - this turns on the fip-snooping capability of the switch o vlan 20,1000 – this moves the interface into vlan 20,1000
fip-snooping enable – this enables the fip-snooping capabilities on these particular VLAN’s. Both must be included for the initial TLV negotiation to establish the FCoE VLAN exit – exit interface configuration o interface out-of-band – move into the interface out-of-band configuration interface
ip address 192.168.100.1 255.255.255.0 192.168.100.254 – this sets the out-of- band management interface IP address, subnet, and gateway for the switch exit – exit the interface configuration o classofservice dot1p-mapping x x – establishes direct CoS mapping for the priorities (must be in place for certain CNA’s o interface te1/0/1 – this moves into the interface te1/0/1 configuration
switchport general pvid 20 – establishes the native VLAN as 20, you must remove VLAN 1 in order for this to function correctly switchport general allowed vlan add 20 - adds VLAN 20 the trunk as an untagged VLAN switchport general allowed vlan add 1000 tagged – this sets up a trunk with a tagged VLAN of 1000 (the FCoE VLAN), and includes the native VLAN as untagged if general mode is enabled. switchport general allowed remove vlan 1 – this removes vlan 1 which would typically be the native vlan otherwise. switchport mode general – this enables the port for general mode lldp dcbx port-role auto-down – sets the DCBx port-role to be auto-down for an ENode connection spanning-tree portfast – sets the ports to a portfast behavior since these are internal- facing server ports. exit – exits the interface configuration

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
o interface te1/0/20 – this moves into the interface te1/0/20 configuration
switchport general pvid 20 – establishes the native VLAN as 20, you must remove VLAN 1 in order for this to function correctly switchport general allowed vlan add 20 - adds VLAN 20 the trunk as an untagged VLAN switchport general allowed vlan add 1000 tagged - – this sets up a trunk with a tagged VLAN of 1000 (the FCoE VLAN), and includes the native VLAN as untagged if general mode is enabled. switchport general allowed remove vlan 1 – this removes vlan 1 which would typically be the native vlan otherwise. switchport mode general – this enables the port for mode general spanning-tree cost 0 – sets spanning tree cost to 0 spanning-tree port-priority 0 – sets this ports priority to 0 so that it has the lowest spanning tree priority in case a loop is created elsewhere on the switch lldp dcbx port-role auto-up – sets the DCBx port-role to be auto-up which dynamically sets the configuration-source for an FCF connection fip-snooping port-mode fcf – enables the port for fip-snooping from an FCF connection exit - exits the interface configuration exit – exits from configuration mode
after important steps so that the switch will retain the configuration settings when the switch is next rebooted or if a power loss occurs. It is also a good practice to copy a well-validated working configuration to a separate location such as the management station for the networks, and have a backup-configuration saved local to the switch.
Further explanation of key points:

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Configuration overview of Dell PowerConnect M8024-k Figure 9.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Configuring the Cisco 5000 series switch with firmware ver 5.x for a single connection from the Dell PowerConnect M8024-k or 8024()(F)
The CLI commands below are necessary for an un-configured Cisco 5020. The CLI will show additional lines that are either default or can’t be changed and are not added for this example. The CLI will also show the lines in a different order after they have been entered. Appendix-A Cisco Nexus 5548UP CLI example will have a copy of the full configuration for a 5548UP for reference.
Sample CLI for Cisco Nexus 5020 (can be copied and pasted) Figure 10.
feature fcoe feature npiv feature telnet feature lacp feature lldp system default switchport trunk mode auto vlan 20 vlan 1000 fcoe vsan 2 vsan database vsan 2 vsan 2 interface vfc1 vsan 2 interface fc2/1 interface vfc1 bind interface Ethernet1/1 no shutdown interface fc2/1 switchport trunk mode auto no shutdown interface Ethernet1/1 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 zone name blade1 vsan 2 member interface fc2/1 member pwwn xx:xx:xx:xx:xx:xx:xx:xx zoneset name set1 vsan 2 member blade1 zoneset activate name set1 vsan 2
Command-Line Interface Method

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
The following CLI commands are necessary for an un-configured Cisco Nexus 5548UP or Cisco Nexus 5596. The full CLI will show additional lines that are either default or can’t be changed and are not added for this example. The CLI will also show the lines in a different order after they have been entered. Appendix-A Cisco Nexus 5548UP CLI example will have a copy of the full configuration.
Sample CLI for Cisco Nexus 5548 (can be copied and pasted) Figure 11.
feature fcoe feature npiv feature telnet feature lacp system default switchport trunk mode auto system qos service-policy type qos input fcoe-default-in-policy service-policy type queuing input fcoe-default-in-policy service-policy type queuing output fcoe-default-out-policy service-policy type network-qos fcoe-default-nq-policy vlan 20 vlan 1000 fcoe vsan 2 vsan database vsan 2 vsan 2 interface vfc1 vsan 2 interface fc2/1 interface vfc1 bind interface Ethernet1/1 no shutdown interface fc2/1 switchport trunk mode auto no shutdown interface Ethernet1/1 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 zone name blade1 vsan 2 member interface fc2/1 member pwwn xx:xx:xx:xx:xx:xx:xx:xx zoneset name set1 vsan 2 member blade1 zoneset activate name set1 vsan 2
SAN Switching Configuration Guide. The CLI entries above only cover the areas that must be added to enable FCoE capabilities on the particular ports being used of a Cisco Nexus 5020 and Nexus 5548. This topic will be covered after the Step by Step explanation of the CLI example.
Command-Line Interface Method

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Step by Step explanation of the CLI example
Configure – this brings you into the configuration interface.
o feature FCOE – enables the feature for FCOE as long as the licensing and FC modules are installed.
o feature NPIV – enables the FC ports to accept multiple logins (Necessary for Compellent).
o feature LACP – enables the switch to be able to use port-channel groups in a LACP mode.
o feature LLDP – enables the switch to use LLDP which is needed for DCBx negotiations. Some switch versions will have this on by default and the entry will not be needed.
o service-policy type qos input fcoe-default-in-policy service-policy type queuing input fcoe-default-in-policy service-policy type queuing output fcoe-default-out-policy service-policy type network-qos fcoe-default-nq-policy - these are qos settings that are in place by default on the 5010 and 5020 Cisco Nexus switches. These settings will have to be input for the 5548 and 5596 Cisco Nexus switches.
o system default switchport trunk mode auto – sets trunk mode to auto for FC ports; optionally this can be set to off, or on if needed.
o vlan 20 – this is the VLAN to be used for the Native VLAN. o vlan 1000 - this is the VLAN being used for FCoE in this example
fcoe vsan 2 – this establishes the previous VLAN 1000 as an FCoE VLAN in VSAN 2.
o vsan database – enter into the vsan database interface.
vsan 2 – initializes VSAN 2 vsan 2 interface vfc1 – set interface vfc1 to be part of VSAN 2 vsan 2 interface fc2/1 – set interface fc2/1 to be part of VSAN 2 o interface vfc1 – selects virtual fc interface vfc1 (vfc1 is an example and can be a different number based on the admin’s choice at configuration time).
Bind interface Ethernet1/1 – this binds interface Ethernet 1/1 to the virtual fc interface which in this case is vfc1. This is one form of binding the VFC. The other form would be to bind the VFC to the FCoE FIP MAC address of the CNA being used. Examples of this will be included later in the document. no shutdown – turns the virtual interface on since default is shutdown. o Interface fc2/1 – selects the fc2/1 interface (which will typically be the first fibre channel port on the Nexus 5020.
no shutdown – turns the fc2/1 interface on since default is shutdown.
o interface Ethernet 1/1 – selects interface Ethernet 1/1
switchport mode trunk – set switchport mode to trunk for the 2 VLAN’s. switchport trunk allowed vlan 1000 – add allowed VLAN 1000 to the trunk.
o system qos

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
o Zone name blade1 vsan 2 – this will set the name for your zone (blade1 can be any chosen name); vsan 2 will match the vsan you have created.
Member interface fc2/1 - this adds the fc2/1 interface as a member of the zone. member pwwn xx:xx:xx:xx:xx:xx:xx:xx – adds the port WWN of the ENode device to the zone. (insert the port WWN of the device being used). o zoneset name set1 vsan 2 – move into the zoneset interface (in this case the name is set1 but could be any name and the VSAN number is based on the FCoE VLAN being used.
member blade1 – this includes the blade1 zone into this zoneset. o zoneset activate name set1 vsan 2 – activates the zoneset containing these zones.
Further explanation of key points:
Cisco Nexus 5000 series configuration sequence Figure 12.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
M1000e Chassis Management Controller -> Server Overview -> Properties -> Figure 13.
WWN/MAC information for Blade Server 3’s “B” fabric CNA port 2 (B2).


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Basic Validation for the Cisco Nexus 5000 series switch configuration With connections made via fiber optic cable or direct connect cable (twin-ax) the basic connectivity on the port between the two switches can be verified. These cables or SFP+ transceivers must only be Cisco-branded products for the Cisco Nexus to link properly. The following command is used to give a port status overview: SHOW INTERFACE BRIEF. This example has been shortened from the actual results but will display the results of active ports and VFC interfaces. Verify that the ports which are expected to have links show up correctly.
Example of show interface brief command Figure 14.
Demo5548-1# show interface brief Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps) fc1/31 2 auto auto up swl F 4 -- fc1/32 2 auto auto up swl F 4 -- Ethernet VLAN Type Mode Status Reason Speed Port Interface Ch # Eth1/1 20 eth trunk up none 10G(D) 2 Eth1/2 20 eth trunk up none 10G(D) 2 Eth1/3 1 eth access up none 10G(D) -- Eth1/4 1 eth access down SFP not inserted 10G(D) -- Eth1/5 1 eth access down SFP not inserted 10G(D) -- Eth1/6 1 eth access down SFP not inserted 10G(D) – *rest of the ports removed for sizing Port-channel VLAN Type Mode Status Reason Speed Protocol Interface Po2 20 eth trunk up none a-10G(D) lacp Port VRF Status IP Address Speed MTU mgmt0 -- up 172.25.188.100 1000 1500 Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps) vfc1 2 F on trunking -- TF auto -- vfc3 2 F on down -- -- -- vfc4 2 F on trunking -- TF auto -- vfc5 2 F on down -- -- -- vfc6 2 F on trunking -- TF auto -- vfc7 2 F on down -- -- -- vfc8 2 F on trunking -- TF auto -- TF auto --

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Check the spanning tree configuration. Blocking ports should be understood and when they show in this entry it should be the number expected. Otherwise it could be that an unintentional cable loop has been created that will need to be resolved. Type : SHOW SPANNING-TREE SUMMARY
show spanning-tree summary command showing current configuration with Figure 15.
Demo-5020-1# show spanning-tree summary Switch is in rapid-pvst mode Root bridge for: VLAN0001 Port Type Default is disable Edge Port [PortFast] BPDU Guard Default is disabled Edge Port [PortFast] BPDU Filter Default is disabled Bridge Assurance is enabled Loopguard Default is disabled Pathcost method used is short

Name Blocking Listening Learning Forwarding STP Active VLAN0001 0 0 0 1 1 1 vlan 0 0 0 1 1
Next, verify that negotiations have happened properly between the FCF and end devices, in this case the Cisco Nexus 5020 is the FCF. Type : SHOW FLOGI DATABASE
show flogi database command showing devices that have completed fabric login Figure 16.
Demo-5020-1# show flogi database INTERFACE VSAN FCID PORT NAME NODE NAME fc2/1 2 0xc6000c 20:04:00:20:c2:10:ab:cd 10:00:00:20:c2:10:ab:cd vfc1 2 0xc60009 20:01:14:fe:b5:07:12:34 20:00:14:fe:b5:07:12:34 Total number of flogi = 2.

At this point the VFC and FC interfaces should be populated in the FLOGI database. This command is showing the devices that have done a valid FLOGI (fabric login) to the Cisco Nexus switch. The VFC should show the expected port and node WWN of the CNA being used in the server.
The following command will show the status of the zones that have been put into place. The asterisks will indicate devices that have an established session (have negotiated and logged in) with the Cisco Nexus 5020. Type : SHOW ZONESET ACTIVE. This command will show the current activated zoneset and all the participating zones with their individual members.
Example of show zoneset active command Figure 17.

Demo-5020-1# show zoneset active zoneset name set1 vsan 2 zone name blade1 vsan 2 * fcid 0xc6000c [interface fc2/1 swwn 20:00:00:05:73:ab:12:34] * fcid 0xc60009 [pwwn 20:01:14:fe:b5:07:12.34]
ports states

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
With all cables in place between the switches and the FC/FCoE SAN, use the following commands to validate your configuration.
First check general status of the ports, and links by using: SHOW INTERFACE STATUS
Show interface status results Figure 18.
PowerConnectM8024-k#show interfaces status Port Name Duplex Speed Neg Link Flow Control State Status Te1/0/1 N/A Unknown Auto Down Inactive Te1/0/2 N/A Unknown Auto Down Inactive Te1/0/3 Full 10000 Auto Up Inactive Te1/0/4 N/A Unknown Auto Down Inactive Te1/0/5 Full 10000 Auto Up Inactive Te1/0/6 N/A Unknown Auto Down Inactive Te1/0/7 Full 10000 Auto Up Inactive Te1/0/8 N/A Unknown Auto Down Inactive Te1/0/9 N/A Unknown Auto Down Inactive Te1/0/10 N/A Unknown Auto Down Inactive Te1/0/11 Full 10000 Auto Up Active Te1/0/12 Full 10000 Auto Up Inactive Te1/0/13 N/A Unknown Auto Down Inactive Te1/0/14 N/A Unknown Auto Down Inactive Te1/0/15 N/A Unknown Auto Down Inactive Te1/0/16 N/A Unknown Auto Down Inactive Te1/0/17 N/A Unknown Auto Down Inactive Te1/0/18 N/A Unknown Auto Down Inactive Te1/0/19 Full 10000 Off Up Inactive Te1/0/20 Full 10000 Off Up Inactive Oob Type Link State --- oob Out-Of-Band Up Port Type Link State Po1 Link Aggregate Down Po2 Link Aggregate Up

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
With the SHOW SPANNING-TREE BLOCKEDPORTS command the status of ports that may be impacted by spanning tree can be checked. This is also a good point to make sure that the spanning-tree behaviors are as expected, such as Priority, which switch is root, etc.
show spanning-tree blockedports command Figure 19.

PowerConnectM8024-k#show spanning-tree blockedports Spanning tree Enabled (BPDU flooding : Disabled) mode rstp CST Regional Root: 80:00:5C:26:0A:AD:0C:39 Regional Root Path Cost: 0 ###### MST 0 Vlan Mapped: 1, 20, 1000 ROOT ID Priority 32768 Address 5C26.0AAD.0C39 This Switch is the Root. Hello Time 2 Sec Max Age 20 sec Forward Delay 15 sec Interfaces Name State Prio.Nbr Cost Sts Role RestrictedPort
On the PowerConnect M8024-k, 8024 or 8024F the sessions can be checked by using: SHOW FIP-SNOOPING. This will show the VLAN’s that are snooped and configured, along with how many FCF’s, and ENode devices that are available. If there is no entry or “0” FCF’s or ENode’s after running this command there is possibly a missed step in the configuration. Proceeding beyond this point will not be possible until this configuration error is corrected.
Show fip-snooping command which gives a brief status on available ENode’s, Figure 20.

Global Mode: Enabled FCoE VLAN List: 20,1000 FCFs: 1 ENodes: 1 Sessions: 2 Max VLANs: 8 Max FCFs in VLAN: 4 Max ENodes: 72 Max Sessions: 1024
and FCF’s · PowerConnectM8024-k#show fip-snooping

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
The following command will show a set of vital information on the DCBX configuration. Type: SHOW
LLDP DCBX INTERFACE ALL. The important things to note with this command are that the configuration source selected is “True” and that the configuration source port is configured as expected to be the uplink to the top-of-rack FCF switch. It can also be noted that ports that are expected to be passing DCBX traffic should have counter statistics listed here.
show lldp dcbx interface all Figure 21.
PowerConnectM8024-k#show lldp dcbx interface all Is configuration source selected True Configuration source port Te1/0/19 DCBX DCBX DCBX unknown Interface Status Role Version Tx Rx Errors TLV Te1/0/1 Enabled Auto-down Auto 0 Te1/0/2 Enabled Auto-down Auto 0 Te1/0/3 Enabled Auto-down Auto 22710 22562 1 0 Te1/0/4 Enabled Auto-down Auto 0 Te1/0/5 Enabled Auto-down Auto 22420 22151 0 0 Te1/0/6 Enabled Auto-down Auto 0 Te1/0/7 Enabled Auto-down Auto 22451 22292 0 0 Te1/0/8 Enabled Auto-down Auto 33 0 0 0 Te1/0/9 Enabled Auto-down Auto 22 35 0 0 Te1/0/10 Enabled Auto-down Auto 0 Te1/0/11 Enabled Auto-down Auto 17175 0 0 0 Te1/0/12 Enabled Auto-down Auto 17179 17310 0 0 Te1/0/13 Enabled Auto-down Auto 0 Te1/0/14 Enabled Auto-down Auto 0 Te1/0/15 Enabled Auto-down Auto 0 Te1/0/16 Enabled Auto-down Auto 0 Te1/0/17 Enabled Manual Auto 0 Te1/0/18 Enabled Manual Auto 0 Te1/0/19 Enabled Auto-up Auto 22707 22861 0 0 Te1/0/20 Enabled Auto-up Auto 22706 22865 0 0
The highlighted port lines show the ports that are actively taking part in FCoE traffic. The role shown by each of the server facing ports should always be auto-down, while the role for the uplinks to the FCF should be auto-up or configuration source. There should be both DCBX Tx counters as well as DCBX Rx counters to show that the negotiations actually occurred with the particular devices.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
The following command will show a set of vital information on the DCBX configuration. Type: SHOW
LLDP DCBX INTERFACE TE1/0/20 DETAIL. This command will show more specific detail about the configuration that has been negotiated between the devices. In this example port te1/0/20 is used as it is one of the uplink ports into the top-of-rack FCF switch.
Some key items in these results will be “true” for peer is configuration source, “Auto-up” for auto- configuration port role and local configuration PFC(3) En/Will/Error configured as Y/Y/N. As an additional note you should also see PFC enable vector: 3:1, this shows that priority queue 3 is set as “strict” and will be lossless.
Show lldp dcbx interface te1/0/20 detail Figure 22.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Finally, after these validation steps, go into the disk management interface of the server. If the SAN is configured appropriately the server will have an available LUN to use for storage.
Problem Potential Problem Area Potential Fix Basic Connectivity Between CNA and 8024 Series switch is not present (ping between devices) Cable is not connected or is failing
Connect or Change cable and reconnect The OS on the server is not configured to have the network card enabled or active
Check adapter settings in the OS and verify ports turned on or enabled
Load driver and ensure both Ethernet and storage device drivers are in place for CNA (if applicable)
The driver for the applicable OS is not loaded
Determine which internal ports should be enabled and configure the ports on with the "no shutdown" command
Internal server facing ports on the M8024-k may not be enabled (no shutdown)
External or regular ports on the 8024 series switch or Cisco Nexus 5000 series switch may not be enabled (no shutdown)
Determine which external ports should be enabled and configure the ports on with the "no shutdown" command
Untagged or Native VLAN's are not configured appropriately. If PVID is changed on 8024 series, VLAN 1 must be removed
Configure Native VLAN's appropriately. See PowerConnect 8024 CLI section or Cisco Nexus 5000 series CLI section for detail on this.
ENode's or FCF entries are not present on the PowerConnect 8024 series switch
See above basic connectivity problems see above Applicable FCoE or storage driver is not configured in the server OS for the CNA
This could be an indication that the storage side of the CNA driver has not been fully installed.
Some CNA's have the option to configure the DCB settings manually. This will potentially cause misbehavior due to the DCBX negotiations not occurring as expected. PowerConnect 8024 may not have appropriate firmware in place, it must be 4.2.0.4 or greater
CNA may not be configured as willing (will negotiate values with the FCF switch)
Download and install firmware 4.2.0.4 or greater see upgrade firmware section
Cisco Nexus 5000 series switch may not have the supported firmware in place. Must be 5.0(2)N1(1) or greater
ENode's or FCF entries are not present on the PowerConnect 8024 series switch- continued -
Download and install latest Cisco firmware.
Feature FCoE may not be configured on Cisco Nexus 5000 series switch
Ensure FCoE feature is configured on Nexus 5000 Series switch
fip-snooping may not be enabled on the native and FCoE VLAN on the Dell PowerConnect 8024 series switch
See PowerConnect 8024 CLI section for explanation of enabling both VLAN's for fip-snooping

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Problem Potential Problem Area Potential Fix
Ensure that VFC's are created that will be applicable to the connection. This can be bound to the FCoE-FIP MAC of the CNA or to the physical interface of the Cisco Nexus 5000 Series switch
The VFC entries may not be present on the Cisco Nexus 5000 series switch
Check VFC entries applicable to the connection and make sure "no shutdown" is part of the configuration for that interface
The VFC entry may not be enable (no shutdown)
The same tagged VLAN should pass FCoE traffic from the PowerConnect 8024 series switch to the Cisco Nexus 5000 series switch. Configure this VLAN appropriately - see CLI explanation sections
The FCoE VLAN may not match on both sides (PowerConnect 8024 and Cisco Nexus 5000 series tagged VLAN entries matched to the FCoE feature)
Configure feature LACP on the Cisco Nexus, and make sure the applicable port-channel is put into the configuration - see CLI explanation sections for further detail Configuration classofservice dot1p- mapping may not be in place on the PowerConnect switch
LACP feature may not be enabled on Cisco Nexus 5000 series switch for applicable LAG's between the two switches
See PowerConnect 8024 CLI section for explanation of applying this configuration
CNA’s that have NPAR capabilities may not have the partitions configured appropriately for FCoE
See CNA documentation for applicable partition settings for FCoE use
FLOGI entries for CNA's are not present on Cisco Nexus 5000 series switch
See above basic connectivity problems see above Verify above section on ENode’s or FCF present on PowerConnect 8024 series switch see above FLOGI entries for FC devices are not present on Cisco Nexus 5000 series switch Cable is not connected or is failing
Connect or Change cable and reconnect
Storage license for Cisco Nexus may not be installed.
Check licenses on Cisco Nexus and install if necessary
End storage device is not powered on Power on Storage device
Storage device is not configured to communicate with FCF or FC switch
Configure storage device to have applicable settings
Configure FC ports for particular storage device and turn on (no shutdown)
FC port on Cisco Nexus not configured
Cisco Nexus may be configured for NPV which allows for the logins to occur on FC switch further downstream
Check configuration of Cisco Nexus. If configured for NPV check for FLOGI logins on the FC switch that the Cisco Nexus is connected to.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Multiple port link (LAG) configuration between switches and storage Figure 23.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Configuring the Cisco Nexus 5000 series switch with firmware ver 5.x for a multiple link LAG (link aggregation) connection at the Top-of-Rack.
The typical scenario in a business environment consists of more than one connection or uplink. The following illustrations and examples describe a two link LAG from an M8024-k to the Cisco Nexus 5020.
Multiple port link (LAG) Cisco 5020 configuration (can be copied and pasted) Figure 24.
Command-Line Interface Method

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Step by Step explanation of CLI example (only covering the differences from the single port configuration) o interface vfc1 – selects virtual fc interface vfc1 (vfc1 is an example and can be a different number based on choice at configuration time) bind interface port-channel1 – this binds interface port-channel1 to the virtual fc interface which in this case is vfc1. no shutdown – turns the virtual interface on since default is shutdown o interface fc2/2 – selects the fc2/2 interface (this is an additional FC port for the 2 connections no shutdown – turns the fc2/1 interface on since default is shutdown
o interface Ethernet 1/1 – selects interface Ethernet 1/1 switchport mode trunk – set switchport mode to trunk for the 2 VLAN’s switchport trunk native vlan 20 – add native VLAN 20 to the trunk switchport trunk allowed vlan 1000 – add allowed VLAN 1000 to the trunk channel-group 1 mode active – this interface is part of a port channel 1 o interface Ethernet 1/2 – selects interface Ethernet 1/2 switchport mode trunk – set switchport mode to trunk for the 2 VLAN’s switchport trunk native vlan 20 – add native VLAN 20 to the trunk switchport trunk allowed vlan 1000 – add allowed VLAN 1000 to the trunk channel-group 1 mode active – this interface is part of port channel 1
o zone name blade1 vsan 2 – this will set the name for your zone (blade1 can be any chosen name), vsan 2 will match the vsan you have created.
member interface fc2/1 - this adds the fc2/1 interface as a member of the zone. member pwwn xx:xx:xx:xx:xx:xx:xx:xx – adds the port WWN of the ENode device to the zone (this should match the CNA of the server being used, in this case blade 2).
o zone name blade2 vsan 2 – this will set the name for your zone (blade1 can be any chosen name), vsan 2 will match the vsan you have created.
member interface fc2/2 - this adds the fc2/1 interface as a member of the zone. member pwwn xx:xx:xx:xx:xx:xx:xx:xx – adds the port WWN of the ENode device to the zone (this should match the CNA of the server being used, in this case blade 2).
o zoneset name set1 vsan 2 – move into the zoneset interface (in this case the name is set1 but could be any name and the VSAN number is based on the FCoE VLAN being used.
member blade1 – this includes the blade1 zone into this zoneset member blade2 – this includes the blade2 zone into this zoneset o zoneset activate name set1 vsan 2 – activates the zoneset containing these zones.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
This is an example of the necessary CLI commands for 8024 model switches configured with two links in a LAG or port-channel uplinked to the Cisco 5020. This provides more bandwidth and fail-over capability which would be more typical in the larger scale infrastructure typically used.
Multiple port uplink (LAG) M8024-k configuration (can be copied and pasted) Figure 25.
Command-Line Interface Method

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Step by Step explanation of Dell PowerConnect M8024-k CLI example with multiple port (LAG) uplink (this only covers the differences from the single port configuration). o interface te1/0/19 – this moves into the interface te1/0/19 configuration
channel-group 1 mode active – adds this interface to the channel-group 1 lldp dcbx port-role auto-up – sets the DCBX port-role to be auto-up for an FCF connection exit - exit the interface configuration o interface te1/0/20 – this moves into the interface te1/0/20 configuration
channel-group 1 mode active – adds this interface to the channel-group 1 lldp dcbx port-role auto-up – sets the DCBX port-role to be auto-up for an FCF connection exit - exit the interface configuration o interface port-channel 1 – this moves into the interface te1/0/20 configuration
switchport general allowed vlan add 1000 tagged - – this sets up a trunk with a tagged VLAN of 1000 (the FCoE VLAN), and includes the native VLAN as untagged if general mode is enabled. switchport mode general – this enables the port for mode general fip-snooping port-mode fcf – enables the port for fip-snooping from an FCF connection exit - exit the interface configuration o exit – exit from configuration mode
Validation Follow the same validation steps as mentioned with the single link steps to ensure that this configuration is working correctly. The ideal method for troubleshooting or validation is to take one link at a time.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Scenario 3: Configuring Multiple Uplinks into LAG for Cisco Nexus 5000 Series Switch (NPV mode) Environment
Multiple link configuration between switches and storage Figure 26.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Configuring the Cisco Nexus 5000 series switch with firmware ver 5.0(3)N2(2a) in NPV mode for a multiple link LAG (link aggregation) connection from the Dell PowerConnect M8024-k or 8024()(F)
The typical scenario in a business environment consists of more than one connection or uplink. The following pictures and examples describe a two link LAG from an M8024-k to the Cisco 5020.
Multiple port link Cisco 5020 configuration (can be copied and pasted) Figure 27.
Command-Line Interface Method

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Step by Step explanation of CLI example for the Cisco Nexus 5000 Series using NPV (only covering the differences from the single port configuration) o feature NPV– enables the NPV feature which turns off zoning. The FC side of the Nexus 5000 series switch effectively turns into just a FC gateway (just passing FC out to another switch). When this feature is enabled the Cisco Nexus 5000 series switch will have to do a full reload because it is completely changing the way it deals with the FC packet behavior. Be prepared for this reload because it may impact a currently running network environment.
Configuring the Dell PowerConnect M8024-k,8024,and 8024F for FIP Snooping with Cisco Nexus 5000 series switch in NPV mode.
The configuration will be the same as previously mentioned in the single or multiple port configurations. The simplicity of the PowerConnect 8024 series switch setup for FIP Snooping is one of the great advantages to using this in an FCoE network.
The 8024 family devices will pass ETS information between end devices and the FCF but local settings are not changed in the 8024 series switches. This process allows for a best effort approach in the default configuration. This will be sufficient for the typical business usage model but for more in-depth settings the following CoS settings can be set in order to apply exact minimum thresholds for the queues that will be used for FCoE or iSCSI. These minimum thresholds are a guaranteed minimum bandwidth for the queues involved, in this case priority queue 3 for FCoE or 4 for iSCSI. The following example is applicable to the FCoE class of service queue 3 settings. (These settings can also be found in the appendix in the full CLI example.)
CoS settings to establish minimum bandwidth for FCoE queue Figure 28.
! Default priority is 0 (CoS queue 0). Untagged frames receive the default priority treatment. ! interface range te1/0/1-16 ! Set CoS queue 3 to strict priority (not WRED) per 802.1Qaz cos-queue strict 3 ! Reserve 50% bw for CoS queue 3 cos-queue min-bandwidth 0 0 0 50 exit interface te1/0/20 ! Set CoS queue 3 to strict priority (not WRED) per 802.1Qaz (traffic selection class 0) cos-queue strict 3 ! Reserve 50% bw for CoS queue 3 - other queues are best effort. ! This bandwidth is shared with other queues if not used cos-queue min-bandwidth 0 0 0 50 Exit
all the internal server-facing ports on the M8024-k modular switch. The settings for te1/0/20 are based on this port being an uplink from the M8024-k modular switch to the Cisco Nexus 5000 series switch. As mentioned above the full configuration with these settings in place can be seen in the Appendix A – M8024-k CLI example.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Further notes on ETS / CoS behavior settings
Careful consideration should be taken when establishing the strict priority queues and managing bandwidth reservations. It FCoE and iSCSI are configured on the same switch and these settings are used to configured both CoS queues it is possible to choke the bandwidth being allowed for regular LAN traffic. As a suggested method limiting the queues for these priorities to 30 or 40 percent would keep this from occurring. The preferred method for configuration is fabric separation or in simpler terms; separating the two storage types onto different switches for ease of management and bandwidth control.
Fabric separation as preferred method for management of networks and Figure 29.

storage

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
new firmware updates. It is important to follow instructions found in those documents if they deviate from this white paper.
Steps for upgrading the firmware on a stack of switches are similar to upgrading the firmware on a single switch. After downloading a new image to the Master by using the File Download page in the Web UI or the copy command in the CLI, the downloaded image is distributed to all member units of the stack. The instructions below will guide you through these steps.
To find the firmware version the switch is using, enter the following command: show version The commands below demonstrate how to copy the firmware file down to the switch via a TFTP server. The switch will need access to the TFTP server on the network and the firmware file will need to be present in the download folder of the TFTP server. Perform the following command from the CLI interface. Press Y when prompted. Be patient as this procedure may take a few minutes
PowerConnectM8024-k #show version Image Descriptions image1 : default image image2 : Images currently available on Flash unit image1 image2 current-active next-active 1 4.1.0.9 4.1.0.6 image1 image1

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Perform another show version command to confirm that the new firmware has been downloaded to the switch. Notice that the firmware was copied into the inactive image for each member. The current-active column now shows the same values as the next-active column. The next step is to activate the image that contains the new firmware. In this example, the switch will need image2 activated. Perform the following commands. Notice that the next-active column now shows different values than the current-active column. Before performing the following update bootcode command, read the Release Notes and any special instructions for updating the firmware release. It is generally required that you update bootcode only on major releases of the firmware, whereas minor releases will not require the update to bootcode. It is recommended to only run this command if required. Press Y when prompted. Updating and rebooting the switch will take a few minutes. If the bootcode is not required, then a simple reload command will need to be performed. After reload, the firmware upgrade is complete.
console#show version Images currently available on Flash unit image1 image2 current-active next-active 1 4.1.0.9 4.2.0.4 image1 image1
console#boot system image2 Activating image image2 .. Images currently available on Flash unit image1 image2 current-active next-active 1 4.1.0.9 4.2.0.4 image1 image2
console#update bootcode Update bootcode and reset (Y/N)?Y Issuing boot code update command... Validating boot code from image...CRC Valid.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
To validate, login to the switch and perform a show version command. For the example given the following is displayed. While downgrading to a previous firmware is supported, all features and functions that were not part
console#show version Images currently available on Flash unit image1 image2 current-active next-active 1 4.1.0.9 4.2.0.4 image2 image2
of the previous firmware will be lost, including those features and functions that were introduced in the current firmware in use. Firmware version 4.2 or later must be active on all switches or stack members in order for stacking and DCB to work. Do not downgrade a switch or stack to firmware version 4.1.x.x or earlier.
Find the firmware versions that the stack members are using.

The commands below demonstrate how to copy the firmware file down to the switch via a TFTP server. The switch will need access to the TFTP server on the network and the firmware file will need to be present in the download folder of the TFTP server. If other methods are preferable over TFTP please see the User’s Guide. Perform the following steps:

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F

The dialog box below will appear after a short period stating that the transfer is complete.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Also notice that the switch still has the same Current-Active image as before.


The Current-Active column should now show the opposite values as what is in the Next-Active column. A reload is required to active the firmware.


Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F

While downgrading to a previous firmware is supported, all features and functions that were not part of the previous firmware will be lost, including those features and functions that were introduced in the current firmware in use. Firmware version 4.2 or later must be active for the DCB or stacking features to work correctly. Do not downgrade the switch to firmware version 4.1.x.x or earlier.

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
show running-config !Current Configuration: !System Description "PowerConnect M8024-k, 4.2.1.3, VxWorks 6.6" !System Software Version 4.2.1.3 !Cut-through mode is configured as disabled !System Operational Mode "Normal" ! configure no mode simple vlan database vlan 20,1000 exit slot 1/0 2 ! PCM8024-k feature fip-snooping vlan 20,1000 fip-snooping enable exit stack member 1 1 ! PCM8024-k exit no logging console username "root" password e6e66b8981c1030d5650da159e79539a privilege 15 encrypted line console exec-timeout 0 exit classofservice dot1p-mapping 1 1 classofservice dot1p-mapping 2 2 classofservice dot1p-mapping 3 3 classofservice dot1p-mapping 4 4 classofservice dot1p-mapping 5 5 classofservice dot1p-mapping 6 6 ! interface Te1/0/1 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
! interface Te1/0/2 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/3 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/4 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/5 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
exit ! interface Te1/0/6 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/7 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/8 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/9 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
lldp dcbx port-role auto-down exit ! interface Te1/0/10 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/11 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/12 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/13 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/14 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/15 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/16 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-down exit ! interface Te1/0/17 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 exit ! interface Te1/0/18 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 shutdown spanning-tree port-priority 0 mtu 2500 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 exit ! interface Te1/0/19 channel-group 2 mode active cos-queue min-bandwidth 0 0 0 50 cos-queue strict 0 3 spanning-tree port-priority 0 mtu 2500 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-up exit ! interface Te1/0/20 channel-group 2 mode active cos-queue min-bandwidth 0 0 0 50 cos-queue strict 0 3 spanning-tree port-priority 0 mtu 2500 switchport general allowed vlan add 20 switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 lldp dcbx port-role auto-up exit ! interface port-channel 2 cos-queue min-bandwidth 0 0 0 50 cos-queue strict 3 spanning-tree port-priority 0 switchport mode general switchport general pvid 20 switchport general allowed vlan add 20

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
switchport general allowed vlan add 1000 tagged switchport general allowed vlan remove 1 mtu 2500 fip-snooping port-mode fcf exit ! interface port-channel 3 mtu 2500 exit ! interface port-channel 4 mtu 2500 exit
Skipped port-channel 5 through 126 for space interface port-channel 127 mtu 2500 exit ! interface port-channel 128 mtu 2500 exit enable password f611e082a05f5562f1d0d2bbcef2b5bf encrypted exit console#

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
!Command: show running-config !Time: Tue Feb 14 22:47:07 2012 version 5.0(3)N2(2a) feature fcoe feature telnet cfs ipv4 distribute feature lacp feature lldp username admin password 5 $1$0bcPjaAd$t3MSaSb34/4QiOx/il5VM0 role network-admin ip domain-lookup hostname Technet5548-1 class-map type qos class-fcoe class-map type queuing class-fcoe match qos-group 1 class-map type queuing class-all-flood match qos-group 2 class-map type queuing class-ip-multicast match qos-group 2 class-map type network-qos class-fcoe match qos-group 1 class-map type network-qos class-all-flood match qos-group 2 class-map type network-qos class-ip-multicast match qos-group 2 system qos service-policy type qos input fcoe-default-in-policy service-policy type queuing input fcoe-default-in-policy service-policy type queuing output fcoe-default-out-policy service-policy type network-qos fcoe-default-nq-policy slot 1 port 31-32 type fc snmp-server user admin network-admin auth md5 0x18e86ba84d1d511fcb6fe4b5e02dc408 priv 0x18e86ba84d1d511fcb6fe4b5e02dc408 loca lizedkey snmp-server enable traps entity fru vrf context management ip route 0.0.0.0/0 172.25.188.254 vlan 1 vlan 20 name NATIVE_VLAN
Technet5548-1# show running-config

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
vlan 1000 fcoe vsan 2 name FCoE_VLAN vsan database vsan 2 interface port-channel2 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 interface vfc3 bind mac-address 14:fe:b5:8e:5b:f2 no shutdown interface vfc4 bind mac-address 14:fe:b5:8e:5b:f0 no shutdown interface vfc5 bind mac-address 14:fe:b5:8e:5c:09 no shutdown interface vfc6 bind mac-address 14:fe:b5:8e:5c:0b no shutdown interface vfc7 bind mac-address 14:fe:b5:8e:5c:26 no shutdown interface vfc8 bind mac-address 14:fe:b5:8e:5c:24 no shutdown vsan database vsan 2 interface vfc3 vsan 2 interface vfc4 vsan 2 interface vfc5 vsan 2 interface vfc6 vsan 2 interface vfc7 vsan 2 interface vfc8 vsan 2 interface fc1/31 vsan 2 interface fc1/32 feature npv feature npiv interface fc1/31 switchport trunk mode on no shutdown

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
interface fc1/32 switchport trunk mode on no shutdown interface Ethernet1/1 interface Ethernet1/2 interface Ethernet1/3 interface Ethernet1/4 interface Ethernet1/5 interface Ethernet1/6 interface Ethernet1/7 interface Ethernet1/8 interface Ethernet1/9 interface Ethernet1/10 interface Ethernet1/11 interface Ethernet1/12 interface Ethernet1/13 interface Ethernet1/14 interface Ethernet1/15 interface Ethernet1/16 interface Ethernet1/17 interface Ethernet1/18 interface Ethernet1/19 interface Ethernet1/20 interface Ethernet1/21 interface Ethernet1/22 interface Ethernet1/23 interface Ethernet1/24

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
interface Ethernet1/25 interface Ethernet1/26 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 interface Ethernet1/27 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 interface Ethernet1/28 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 interface Ethernet1/29 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 channel-group 2 mode active interface Ethernet1/30 switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 1000 channel-group 2 mode active interface mgmt0 ip address 172.25.188.100/16 line console line vty boot kickstart bootflash:/n5000-uk9-kickstart.5.0.3.N2.2a.bin boot system bootflash:/n5000-uk9.5.0.3.N2.2a.bin interface fc1/31 switchport mode NP interface fc1/32 switchport mode NP

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024, and 8024F
Version information for the network switches used in creating this document are as follows:
Switch Firmware Versions Table 1.
Network switch Dell PowerConnect™
Software version 4.2.0.1, 4.2.0.2, 4.2.0.3, 4.2.0.4, 4.2.1.3 4.2.0.1, 4.2.0.2, 4.2.0.3, 4.2.0.4, 4.2.1.3 5.0(3)N2(2a), 5.0(3)N1(1b)
Fibre Channel over Ethernet Initialization Protocol, Cisco, http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/white_paper_c11- 560403.html
T11/09-291v0 FIP VLAN discovery updates, T11, http://www.t11.org/ftp/t11/pub/fc/bb-5/09-291v1.pdf
IEEE. (2008, November 24). 802.1Qaz/D0.2. Draft Standard for Local and Metropolitan Area Networks –
Virtual.
IEEE. (2009, Feb 9). 802.1Qbb/D1.0. Draft Standard for Local and Metropolitan Area Networks – Virtual.
Cisco Systems, Inc. (2011). Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release
5.0(3)N2(1). San Jose: Cisco Systems, Inc.
Dell (NASDAQ: DELL) is a leading technology provider to commercial and public enterprises around the world.
Dell PowerConnect™ · 8024/8024F Cisco 5020 · M8024k