Operator’s Manual
3M Library Systems 3M Center, Building 225-4N-14 P.O. Box 33225 St. Paul, MN 55133-3225
Printed in U.S.A. E 3M 1999 September 78-6970-6943-9 Rev B. Printed on recycled paper.

3M, Tattle-Tape, and SelfCheck are trademarks of 3M Company.





Section 1. Introduction
From the best-trained field service organization, to our technical service group and customer support staff, we are committed to providing you with the support you require to ensure your complete satisfaction.
The Global Leader in Library Materials Flow Management
People who remove materials from libraries without authorization are much like your average patron. Library materials are usually placed within book bags, briefcases or concealed under clothing. 3M detection systems have been designed to detect the unauthorized removal of materials concealed in this manner. While a 100% electronic net does not exist, the 3M system provides effective protection and significant reduction in the loss of library materials.
3M pioneered the concept of electronic protection of library materials more than 25 years ago. We are still leading the way.
Today, thousands of libraries around the world use the 3Mt Library Security System to protect their valuable collections. In fact, more libraries trust 3M than all other library security systems combined.
What this means to you
With a little attention and care, your 3M system should provide you with many years of service and help to protect your library against thousands of dollars in losses.
This manual explains how your 3M Library Security System operates. By becoming familiar with the information this manual contains, you and your staff will derive the maximum benefits from your system. But do not hesitate to contact us if you have questions.
Call our toll-free 800 number any time of day or night for service, to order supplies, to leave messages for your sales representative, or to contact the 3M credit department:
1-800-328-0067

Blank Page

Section 2. How the System Works
Checking out materials is accomplished using desensitizers to “turn off” the strips while resensitizers are used to turn the strips back on when materials are returned to the library. This allows for full circulation of all library materials.
Your 3Mt Library System consists of several components, including 3Mt Tattle-Tapet Security Strips, circulation accessories, and the detection system(s).
The 3M detection system is designed to detect sensitized 3M Tattle-Tape security strips and then sound an alarm, thus preventing unauthorized removal of library materials.
The key to the effectiveness of the system is protecting your materials with 3M Tattle-Tape security strips. Only when materials are protected can the 3M Detection system detect someone trying to leave the library without properly checking out items.
It is this simple:
Mark materials as described in this manual.
Circulate materials using desensitizers and resensitizers described in the Accessories section.
The primary zone of detection between the lattices extends from the floor to 72 inches [1,82 m] above the floor. The electronic coverage in this area is not 100% and it will vary with the options you have and the type of 3M security markers you use. The rate of detection in this area is effective to deter the loss of protected materials.
Listen for the 3M detection system alarm to sound when unauthorized removal of materials occurs. Of course, it is also important to watch for suspicious actions such as holding materials above the head and passing items around the lattices when passing through the detection system.
3M offers several models of detection systems to meet your library’s needs. See the next section for the details on the various models.


Blank Page

Section 3. System Configuration
3.1 Models 2301 and 2302
The detection lattices are shown below:
Patron Counter/Alarm Counter/ Diagnostic Display
Patron Counter/Alarm Counter/ Diagnostic Display

FCC Radio Frequency Rules and Regulations
Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de Classe A prescrites dans le reglement sur le brouillage radioelectrique edicte par le Ministere des Communications du Canada.
This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The safety related fire, shock, and injury aspects of the Model 2300 series have been investigated to UL 1950, CSA 22.2 No. 950, and EN 60950 standards by Underwriters Laboratories Inc. Burglary and theft protection features have not been evaluated.
DOC Radio Frequency Rules and Regulations
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the radio inteference regulations of the Canadian Department of Communications.

3.3 Accessories
3.4 Security Strips
A variety of accessories is available for use with your 3Mt Detection System Model 2301/2302. However, it is unlikely that any one customer will use every accessory.
3M has a wide range of security strips to protect your merchandise. Any of the security strips listed below may be used effectively with the detection systems Models 2301/2302.
3M Tattle-Tape Security Strips
The 3Mt Desensitizers are designed to desensitize 3Mt Tattle-Tapet Security Strips. Security strips on protected items must be properly desensitized so the items can be carried through the system without causing an alarm.
B1 - for print materials B2 - for print materials DAC-1 - for audio cassettes DCD-2 - for audio CDs and CD-ROMs DSA-1 - for audio cassettes DVM-1 - for video cassettes
3M desensitizers used with 3M Tattle-Tape security strips:
Model 763 On-counter, magnetic media Model 766 Handheld, magnetic media Model 930 On-counter Model 2001 On-counter, magnetic media (strips only) Model 2001M On-counter, magnetic media Model 2004 In-counter Model 955 Bookcheck Model 966 Bookcheck
Security strips on protected items must be properly resensitized to ensure items carried through the system will cause an alarm.
3Mt Resensitizers used with 3M Tattle-Tape security strips:
Model 2011 On-counter, magnetic media Model 955 Bookcheck Model 966 Bookcheck Model 951 Handheld Model 764 On-counter, for printed material and compact discs
Locking exit gates and an entrance gate can be installed on the system.
3Mt SelfCheckt System
The 3Mt SelfCheckt System is a library system used by patrons to check out their own library materials. It completes library loan transactions by desensitizing 3M Tattle-Tape security strips and recording the transaction in the library circulation system.
Desensitizers · Resensitizers · Gates

3.5 Turning Your System On
3.6 How to Verify System Operation
Your 3Mt Detection System Model 2301/2302 has been designed to be left on continuously.
Your 3M detection system Model 2301/2302 should be inspected daily for proper operation.
To turn the system on:
System operation may be verified with the built-in Diagnostic Display which is located on lattice A. During normal operation, the current patron count and alarm count will be displayed. A leading “P” indicates a patron count (for example, P123456). A leading “A” indicates an alarm count (for example, A1234).
2301/2302 Baseplate Mounting - Connect the power cord to a power outlet.
2301/2302 Direct Mount - Connect the power cord to a power outlet, and turn the key switch to On.
If a system problem should occur, a code number will appear in the Diagnostic Display. Refer to the Troubleshooting Guide, Section 6-9, if a code number is present.
Allow two minutes for the system to warm up.

An alarm condition is indicated by an audible signal. The specific corridor in which an alarm condition exists is indicated by the light built into the top of lattice A or C.
There is no need for repetitive walk-through testing.

3.7 Emergency Shutdown
If an emergency occurs, remove power from the system by one of the following methods:

3.8 Models 3501 and 3502
The Detection Panels are shown below:
Fuse & voltage selector
Power cord Panel A

Fuse & voltage selector

3.9 FCC/Industry Canada/European/Australia EMC Compliance
Industry Canada Radio Frequency Rules and Regulations
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
FCC Radio Frequency Rules and Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can emit radiated radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.
This unit complies with the EMC requirements for Australia.

Australia













3.10 M3501/M3502 Detection System
! Caution
Personal Injury Hazard.
The 3Mt Detection System Model 3501/3502 is designed to detect the unauthorized removal of media from the library. It is designed to be positioned inside the library at the library exit. All exiting traffic should be directed through the Model 3501/3502 to maximize effectiveness. This system is designed for continuous operation. For maximum protection of the library media, use Tattle-Tapet Security Strips and 3Mt Accessories.
Attempting to change fuses without unplugging the Detection System may cause personal injury. Inserting the fuse holder in the incorrect direction could blow the fuse.
To avoid any possibility of injury, disconnect the power before attempting to change the fuse. To avoid blowing the fuse, insert the fuse holder in the correct direction. For continued protection against risk of fire, replace only with the same type and rating of fuse.
! WARNING
Possible personal injury or equipment damage. Incorrect configuration and installation of the 120/240 voltage selector may cause personal injury or equipment damage.
Personal Injury Hazard. Risk of electrical shock present. Not operator serviceable. Refer all servicing to 3M factory trained service personnel. Do not open of enter panels or electronic enclosure.
Install the fuse holder/voltage selector in the correct orientation. See additional information in this manual on voltage configuration and fuses.
High Voltage · Internal Use · High Voltage

3.11 Accessories
3.12 Security Strips
A variety of accessories is available for use with your 3Mt Detection System Model 3501/3502. However, it is unlikely that any one customer will use every accessory.
3M has a wide range of security strips to protect your merchandise. Any of the security strips listed below may be used effectively with the detection systems Models 3501/3502.
3M Tattle-Tape security strips
The 3Mt Desensitizers are designed to desensitize 3Mt Tattle-Tapet Security Strips. Security strips on protected items must be properly desensitized so the items can be carried through the system without causing an alarm.
B1 - for print materials B2 - for print materials DAC-1 - for audio cassettes DCD-2 - for audio CDs and CD-ROMs DSA-1 - for audio cassettes DVM-1 - for video cassettes
3M Desensitizers used with 3M Tattle-Tape security strips:
Model 763 On-counter, magnetic media Model 766 Handheld, magnetic media Model 930 On-counter Model 2001 On-counter, magnetic media Model 2001M On-counter, magnetic media Model 2004 In-counter Model 955 Bookcheck Model 966 Bookcheck
Security strips on protected items must be properly resensitized to ensure items carried through the system will cause an alarm.
3Mt Resensitizers used with 3M Tattle-Tape security strips:
Model 2011 On-counter, magnetic media Model 955 Bookcheck Model 966 Bookcheck Model 951 Handheld Model 764 On-counter, for printed material and compact discs
3Mt SelfCheckt System
The 3Mt SelfCheckt System is a library system used by patrons to check-out their own library materials. It completes library loan transactions by desensitizing 3M Tattle-Tape security strips and recording the transaction in the library circulation system.
Desensitizers · Resensitizers

3.13 Turning Your System On
3.14 How to Verify System Operation
The 3Mt Detection System Model 3501/3502 is designed to be left on continuously.
Your 3Mt Detection System Model 3501/3502 should be inspected daily for proper operation.
To turn on, connect the Electronics Enclosure power cord to a power outlet. Turn the On/Off key switch to ON. The Power On indicator light should be on.
Proper system operation is indicated when the red power indicator light is illuminated. System operation may be verified by passing through the system with a marked book, which should result in an audible alarm and a light on at the top of the panels. Each pass through the system should also increment the counter by one. The alarm/inhibit light on the Electronics Enclosure should also be illuminated (green) at the time of alarm. If the system does not respond, see the Troubleshooting Guide in Section 6.
Allow 15 seconds for the system to start up.
There is no need for repetitive walk-through testing.

3.15 Emergency Shutdown

If an emergency occurs, remove power from the Model 3500 system by one of the following methods:

The fuses are located on the bottom of the Electronic Enclosure in the power entry connector.



a. Up to 125VAC, use a 4A fuse.
b. Voltages over 125VAC to 250VAC, use a 3.15A fuse.

3.17 Models 3801 and 3802
The Detection Panels are shown below:


The 3800 System is also available in a 3-corridor 3803 model and a 4-corridor 3804 model.

3.18 Accessories
3.19 Security Strips
A variety of accessories is available for use with your 3Mt Detection System Model 3801/3802. However, it is unlikely that any one customer will use every accessory.
3M has a wide range of security strips to protect your merchandise. Any of the security strips listed below may be used effectively with the Detection Systems Models 3801/3802.
3M Tattle-Tape Security Strips
The 3Mt Desensitizers are designed to desensitize 3Mt Tattle-Tapet Security Strips. Security strips on protected items must be properly desensitized so the items can be carried through the system without causing an alarm.
B1 - for print materials B2 - for print materials DAC-1 - for audio cassettes DCD-2 - for audio CDs and CD-ROMs DSA-1 - for audio cassettes DVM-1 - for video cassettes
3M desensitizers used with 3M Tattle-Tape security strips:
Model 763 On-counter, magnetic media Model 766 Handheld, magnetic media Model 930 On-counter Model 2001 On-counter, magnetic media Model 2001M On-counter, magnetic media Model 2004 In-counter Model 955 Bookcheck Model 966 Bookcheck
Security strips on protected items must be properly resensitized to ensure items carried through the system will cause an alarm.
3Mt Resensitizers used with 3M Tattle-Tape security strips:
Model 2011 On-counter, magnetic media Model 955 Bookcheck Model 966 Bookcheck Model 951 Handheld Model 764 On-counter, for printed material and compact discs
Locking exit gates and an entrance gate can be installed on the system.
3Mt SelfCheckt System
The 3Mt SelfCheckt System is a library system used by patrons to check-out their own library materials. It completes library loan transactions by desensitizing 3M Tattle-Tape security strips and recording the transaction in the library circulation system.
Desensitizers · Resensitizers · Gates

3.20 Turning Your System On
3.21 How to Verify System Operation
The power On/Off switch is a key switch located on one end of the corridor at the base of the electronics chassis. The 3Mt Detection System Model 3801/3802 is designed to be left on continuously.
Your 3M detection system Model 3801/3802 should be inspected daily for proper operation.
System operation may be verified with the built-in Diagnostic Display located on one security panel. During normal operation, the current patron count or alarm count will be alterately displayed at 15 second intervals. A leading “P” indicates a patron count (for example, P123456). A leading “A” indicates an alarm count (for example, A123456).
To turn the system on, insert the key and turn the key switch to the ON position. The green light above the key switch will light, indicating the system is on. They key should always be removed from the system to prevent tampering.
Allow two minutes for the system to warm up. A “DIAG9” will appear in the “Patron Counter/Diagnostic Display” during warm-up. Thereafter, the patron count or alarm count will be displayed.
If a system problem should occur, a code number will appear in the Diagnostic Display. Refer to the Troubleshooting Guide, Section 6, if a code number is present.
An alarm condition is indicated by an audible signal. The specific corridor in which an alarm condition exists is indicated by the light built into the top of panel A or C.
There is no need for repetitive walk-through testing.

3.22 Emergency Shutdown
3.24 DOC Radio Frequency Rules and Regulations
If an emergency occurs, remove power from the system by one of the following methods:
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the radio inteference regulations of the Canadian Department of Communications.
The safety related fire, shock, and injury aspects of the Model 2300, 3500, and 3800 series have been investigated to UL 1950, CSA 22.2 No. 950, and EN 60950 standards by Underwriters Laboratories Inc. Models also comply with European CE requirements. Burglary and theft protection features have not been evaluated.
This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Blank Page

Section 4. 3M Accessories for Use with the 3Mt Library Security System
Accessories Used with the 3M Library Security System
Desensitizers Page M766 Handheld magnetic media 4-2 M930 On-counter 4-4 M2001 On-counter, magnetic media 4-6 . . M2001M On-counter, magnetic media 4-8 . . M2004 In-counter, general use 4-10 M955 Bookcheck 4-17 M966 Bookcheck 4-21 M763 On-counter, magnetic media 4-25 . .
3M has a variety of security strips and accessories, desensitizers and resensitizers for use with the 3Mt Library Security System. Security strips and their uses are described in Section 5.
This section contains information for proper use and operation of the accessories used with the 3M detection systems. You may have one or more of these accessories depending on your operation, volume, and selection of materials to be protected. For specific information on using your accessory devices, locate the page(s) describing the device.
Resensitizers M2011 On-counter, magnetic media 4-12 . . M951 Handheld 4-14 M955 Bookcheck 4-17 M966 Bookcheck 4-21 M764 On-counter, print and CD media4-27
Gate M494 Locking Exit or Entrance Gate 4-30
3Mt SelfCheckt System M5210 SelfCheck System 4-31 M5220 SelfCheck System 4-32 M6210 SelfCheck System 4-33 M4210 SelfCheck System 4-34
3Mt Staff Workstation M995 Staff Workstation 4-35
Description/Characteristics

4.1 3Mt Handheld Desensitizer Model 766 (For Use With Recorded Magnetic Media)
Draw the 3M Model 766 across the marked article with the desensitizing element in full contact with the security strip.
The 3M Desensitizer Model 766 is designed to desensitize surface-applied 3Mt Tattle-Tapet Security Strips. This includes security strips which have been applied to recorded magnetic media such as audio cassettes, video cassettes, or boxed computer software.

Security strips on protected items must be properly desensitized so the items can be carried through the library system without causing an alarm.

Only one pass is necessary to fully desensitize a security strip.
Passing the 3M Model 766 across the security strip first in one direction and then in the other (scrubbing motion) may partially resensitize the security strip and cause unwanted alarms.
The 3M Model 766 is a non-electric, handheld device which requires no installation. However, the security cable should be attached to prevent unauthorized removal.

Security Strips Used with the 3M Model 766 Desensitizer
Typical Items Used with the 3M Model 766 Desensitizer
3Mt Tattle-Tapet Security Strips (surface-applied)
Make sure that the 3M Model 766 desensitizing element contacts the security strip.
DVM-1
DAC-1
All general items (with surface-applied security strips)
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
To avoid damage to credit cards or computer disks, do not permit the 3M Model 766 to make direct contact with credit cards or computer disks.
The 3M Model 766 should be used and stored away from areas which are readily accessible to customers.
Security Strip Storage Conditions
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock, first in, first out.

4.2 3Mt On-Counter Desensitizer Model 930 (Not For Use With Recorded Magnetic Media)
To desensitize security strips in books or magazines:
Draw the spine of the book or magazine across the top of the 3M Model 930. Keep the spine of the marked item in full contact with the desensitizer.
The 3Mt On-counter Desensitizer Model 930 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, and other general items.

The 3M Model 930 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer disks as they may be damaged.
Security strips on protected items must be properly desensitized so the items can be carried through the library system without causing an alarm.

To desensitize security strips on general items and unrecorded magnetic media:
Draw the marked item across the top of the 3M Model 930. Keep the security strip in full contact with the desensitizer.

The 3M Model 930 is a moveable, non-electric, on-counter device which requires no installation. However, it should be located away from areas which are readily accessible to customers.
A yellow warning label is supplied by 3M and should be secured on or near the 3M Model 930 to advise customers of potential damage to recorded magnetic media.
Only one pass is necessary to fully desensitize a security strip.
Passing the marked item across the 3M Model 930 first in one direction and then in the other (scrubbing motion), may partially resensitize the security strip and cause unwanted alarms.

Security Strips Used with 3Mt Desensitizer Model 930
Typical Items Used with 3M Model 930 Desensitizer
3Mt Tattle-Tapet Security Strips
All general items — excluding recorded magnetic media.
B2 (DS-B2-N)
DCD-2
Keep credit cards, recorded magnetic media (audio tapes, video tapes or computer disks) and stem-wind and self-wind wrist watches at least six inches [150 mm] away from the 3M Model 930 surface to prevent magnetic damage. A yellow warning label is supplied by 3M and should be secured on or near the 3M Model 930 to advise customers of potential damage to recorded magnetic media. Keep a minimum of 12 inches from computers and computer displays (CRTs).
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
The 3M Model 930 should be installed away from areas which are readily accessible to customers.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Security Strip Storage Conditions
Store security strips at 50 -- 90F [10 -- 32 C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.
Store security strips at least two feet [0,6 m] away from the 3M Model 930.

4.3 3Mt On-Counter Desensitizer Model 2001 (For Use With Recorded Magnetic Media)
To desensitize security strips:
S Draw the marked item across the black plate on the Model 2001.
The 3Mt On-counter Desensitizer Model 2001 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to records, audio cassettes, and prepackaged computer software.
S Make sure the security strip is in full contact with the black plate on the Model 2001.

This device is not intended to desensitize security strips which have been applied directly to computer software, as the disks may be damaged.
Security strips on protected items must be properly desensitized so the items can be carried through the library security system without causing an alarm.

Only one pass is necessary to fully desensitize a security strip.
Passing the marked item across the 3M Model 2001 first in one direction and then in the other (scrubbing motion) may partially resensitize the strip and cause unwanted alarms.
The 3M Model 2001 is a moveable, non-electric, on-counter device which requires no installation. However, the 3M Model 2001 should be used away from areas which are readily accessible to customers.
To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001.

Security Strips Used with the 3Mt Desensitizer Model 2001
Typical Items Used with the 3M Model 2001 Desensitizer
3Mt Tattle-Tapet Security Strips
DVM-1
DSA-1
To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001. Computer software disks should be enclosed in a box or case to keep the disks at least 1/4 inch [6 mm] from the Model 2001 surface.
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
The 3M Model 2001 should be used and stored away from areas which are readily accessible to customers.
Security Strip Storage Conditions
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.

4.4 3Mt On-Counter Desensitizer Model 2001M (For Use With Recorded Magnetic Media)
To desensitize security strips:
S Draw the marked item across the black plate on the Model 2001M.
The 3M On-counter Desensitizer Model 2001M is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to records, boxed audio cassettes, video cassettes, compact disks and boxed computer software.
S Make sure the security strip is in full contact with the black plate on the Model 2001M.

This device is not intended to desensitize security strips which have been applied directly to unboxed audio cassettes or to computer software, as they may be damaged. However, security strips may be applied to boxed computer software.
Security strips on protected items must be properly desensitized so the items can be carried through the library security system without causing an alarm.

Only one pass is necessary to fully desensitize a security strip.
Passing the marked item across the 3M Model 2001M first in one direction and then in the other (scrubbing motion) may partially resensitize the security strip and cause unwanted alarms.
The 3M Model 2001M is a non-electric, moveable on-counter device which requires no installation. However, the security cable should be attached to prevent unauthorized removal.
To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001M.

Security Strips Used with the 3Mt Desensitizer Model 2001M
Typical Items Used with the 3M Model 2001M Desensitizer
3Mt Tattle-Tapet Security Strips
DSA-1
DVM-1
To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001M. Computer software disks should be enclosed in a box or case to keep the disks at least 1/4 inch [6 mm] from the Model 2001 surface.
Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
The 3M Model 2001M should be installed away from areas which are readily accessible to customers.
Security Strip Storage Conditions
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.

4.5 3Mt In-Counter Desensitizer Model 2004 (Not For Use With Recorded Magnetic Media)
Pass the marked article across the face of the Model 2004 with the security strip in full contact with the surface of the desensitizer.
The 3Mt Desensitizer Model 2004 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips in or on books, magazines, and other general items.

The 3M Model 2004 is not intended to be used with recorded magnetic media such as audio or video cassettes or computer software.
Security strips on protected items must be properly desensitized so the items can be carried through the library system without causing an alarm.

The 3M Model 2004 is a non-electric device which is designed to be permanently installed in the checkout counter.
A yellow warning label is supplied by 3M and should be secured on or near the Model 2004 to advise customers of potential damage to recorded magnetic media.
Only one pass is necessary to fully desensitize a security strip.
Passing the marked item across the 3M Model 2004 first in one direction and then in the other (scrubbing motion) may partially resensitize the security strip and cause unwanted alarms.

Security Strips Used with the 3Mt Desensitizer Model 2004
Typical Items Used with the 3M Desensitizer Model 2004
3Mt Tattle-Tapet Security Strips
All general items — excluding recorded magnetic media.
B2 (DS-B2-N)
DCD-2
Keep credit cards, recorded magnetic media (audio tapes, video tapes or computer disks) and stem-wind and self-wind wrist watches at least six inches [150 mm] away from the 3M Model 2004 surface to prevent magnetic dam- age. A yellow warning label is supplied by 3M and should be secured on or near the 3M Model 2004 to advise customers of potential damage to recorded magnetic media. Keep a minimum of 12 inches ffom computers and computer displays (CRTs).
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Security Strip Storage Conditions
Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.
Store security strips at least two feet [0,6 m] away from the Model 2004.

4.6 3Mt On-Counter Resensitizer Model 2011 (For Use With Recorded Magnetic Media)
To resensitize security strips, pass the marked article across the surface of the 3M Model 2011. Make sure the security strips are in full contact with the 3M Model 2011.
The 3Mt On-counter Resensitizer Model 2011 is designed to resensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to audio cassettes or video cassettes.
Strips passed across the 3M Model 2011 in the direction opposite the arrows will not be resensitized.

This device is not intended to resensitize security strips which have been applied directly to computer disks, as the disks may be damaged.
Security strips must be resensitized when the marked items are returned. Improperly resensitized items will not alarm when passed through the library system.

The 3M Model 2011 is a moveable, non-electric, on-counter device which requires no installation.
The 3M Model 2011 should be located away from areas which are readily accessible to customers.
Only one pass is necessary to fully resensitize each security strip.
To avoid damage to credit cards or computer software: Do not attempt to resensitize security strips which have been applied directly to computer software. Do not permit credit cards or computer software disks to make direct contact with the 3M Model 2001.

Security Strips Used with the 3Mt Resensitizer Model 2011
Typical Items Used with the 3M Resensitizer Model 2011
3Mt Tattle-Tapet Security Strips
DVM-1
To avoid damage to credit cards or computer software: Do not attempt to resensitize security strips which have been applied directly to computer software. Do not permit credit cards or computer software disks to make direct contact with the 3M Model 2001.
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips and labels.
Security Strip Storage Conditions
Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.

4.7 3Mt Handheld Resensitizer Model 951 (Not For Use With Recorded Magnetic Media)
The 3M Model 951 is a portable device which requires no installation other than plugging it into the proper power source.
The 3Mt Resensitizer Model 951 is designed to resensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, periodicals, and compact discs.
The 3M Model 951 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer software.
The 3M Tattle-Tape security strips should be resensitized when the protected items are returned. Improperly resensitized items will not alarm when passed through the detection system.

Installation · Description/Characteristics · Model 951

The center of the Model 951 must pass directly over the security strip and no farther than1/4 inch [6 mm] above the strip.
Turn the Model 951 on at least six inches [150 mm] from the 3Mt Tattle-Tapet Security Strip.


Pass the resensitizer slowly along the object where the security strip is located. Continue beyond the security strip before turning the resensitizer off.

The recommended duty cycle for the Model 951 is one minute on and five minutes off.
3 inches 76 mm
1 second 1 segundo

Operating Instructions · Resensitizing Security Strips

Security Strips Used with the 3Mt Resensitizer Model 951
Problem: The Model 951 will not resensitize any strip.
3Mt Tattle-Tapet Security Strips
D The Model 951 is not connected to a working power outlet.
B2
Solution: Plug the Model 951 into a working power outlet.
D The internal thermal sensor is open.
Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
The resensitizer may have been used or turned “ON” for too long a time, allowing it to over heat. The recommended duty cycle is one minute on and five minutes off.
Typical Items Used with the 3M Resensitizer Model 951
Solution: Allow the Model 951 to cool.
Problem: Poor or inconsistent resensitizing.
D Passing the Model 951 along the length of a security strip too fast.
Solution: Slow the speed for resensitizing to approximately three inches [75 mm] per second.
D The center of the Model 951 resensitizing element is not directly over the security strip.
Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least six inches [150 mm] away from the 3M Model 951 surface to prevent magnetic damage.
D The Model 951 is more than 1/4 inch [6 mm] away from the security strip.
Solution: Verify that the Model 951 is being used directly over the security strip and is not more than 1/4 inch [6 mm] away from the security strip.
Security Strip Storage Conditions
Store security strips at 50 -- 90 F (10 -- 32 C) and at 20 -- 70% relative humidity.
Problem: Cracked or damaged housing.
Store security strips in a clean area and out of direct sunlight. Rotate stock.
Solution: Discontinue use immediately. The Model 951 is not repairable. Replace the unit.

4.8 3Mt Bookcheck Model 955 (Not For Use With Recorded Magnetic Media)
The Model 955 may be placed either on or under the circulation counter.
The 3Mt Bookcheck Model 955 is designed to desensitize and resensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, periodicals, and compact discs.
The Model 955 is capable of operating from a nominal voltage of 115 volts or 230 volts. The voltage selection switch on the back of the Model 955 must be moved to the proper position before it may be used for the first time.
The Model 955 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer software.
Set the voltage selection switch to the 115 position when operating from 100 to 130 volts.
The Model 955 also has a verifier switch and light. When the verifier switch is in the ON position, the verifier light identifies materials which are protected with active 3M Tattle-Tape security strips.
Set the voltage selection switch to the 230 position when operating from 200 to 240 volts.

Security strips and labels on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.
When items are returned, the security strips can be resensitized. Improperly resensitized items will not alarm when passed through the detection system.


Select the Sensitize mode.
Select the Desensitize mode.
Place the spine of the marked book or an edge of a compact disc in the cradle of the bookcheck.
Place the spine of a marked book or a compact disc in the cradle of the bookcheck.
Slide the item to the left. As the item passes the optical trigger an audible signal (thump) will indicate the 3M Tattle-Tape security strip has been resensitized.
Slide the item to the left. As the item passes the optical trigger, an audible signal (thump) will indicate the 3Mt Tattle-Tapet Security Strip has been desensitized.
The orange verifier light will also turn on, confirming that the security strip has been properly resensitized. If the verifier light does not turn on, then the item is not marked with a 3M Tattle-Tape security strip.
The orange verifier light will also turn off, confirming that the security strip has been properly desensitized.
To ensure items will be properly desensitized, do not place more than one item at a time in the cradle of the Model 955.
To ensure that items will be properly resensitized, do not place more than one item at a time in the cradle of the Model 955.




Verifying that materials are protected with 3Mt Tattle-Tapet Security Strips
Problem: The optical sensor area may have accumulated dust.
When the VERIFIER switch is in the ON position, the verifier light will identify which items in your collection are protected with 3Mt Tattle-Tapet security strips.
Solution: Clean this area by blowing or brushing dust from the optical sensors.
! Caution To reduce the risk of electrical shock, do not use liquids to clean the optical sensor.
To verify that an item is protected with a 3M security strip, resensitize the item as described on the previous page.
Make sure the Sensitize/Desensitize switch is in the SENSITIZE position.

Place the item in the center of the Model 955 with the item gently touching the vertical portion of the unit.
If the item is protected, the verifier will light. If the verifier does not light, then you will want to install a 3M Tattle-Tape security strip to protect the item.

Resetting the circuit breaker
The Model 955 bookcheck will not operate if the circuit breaker is open.
S Reset the circuit breaker on the back of the bookcheck one time.
S If the bookcheck does not operate correctly after resetting the circuit breaker one time, call 3M service at 1-800-328-0067.

No desensitizing or resensitizing
resensitize any strip.
D The Model 955 fails to operate or “thump.”
Problem: The Model 955 is not connected to a working power outlet.
Solution: Plug the Model 955 into a working power outlet.
Optical Sensor Area · Troubleshooting · Circuit Breaker

Security Strips Used with the 3Mt Bookcheck Model 955
Typical Items Used with the 3M Bookcheck Model 955
3Mt Tattle-Tapet Security Strips
B2
DCD-2
Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least 6 inches [150 mm] away from the 3M Model 955 surface to prevent magnetic damage.
The Model 955 should be installed away from areas which are readily accessible to patrons.
Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a grease cutting cleaner. Rub on the surface until clean and wipe dry.
Security Strip Storage Conditions
Store security strips at 50 -- 90 F [10 -- 32 C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

4.9 3Mt Bookcheck Model 966 (Not For Use With Recorded Magnetic Media)
The Model 966 is designed to be installed in the circulation counter. It is also designed to be reversible, allowing you to process materials in a right-to-left or left-to-right motion. However, once installed in the counter, materials can be processed in one direction only. The library staff should indicate their preference of direction to the 3M service representative during the installation.
The 3Mt Bookcheck Model 966 is designed to desensitize and resensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, periodicals, and compact discs.
The Model 966 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer software.
The library is responsible for cutting the mounting hole for the Model 966 in the circulation counter top and for mounting the Model 966 to the counter. Instructions for completing this portion of the installation are included with the Model 966.
The Model 966 also has a verifier switch and light. When the verifier switch is in the ON position, the verifier light identifies materials which are protected with active 3M Tattle-Tape security strips.
Once the Model 966 is mounted in the counter, the 3M service representative will complete the electrical installation of the Model 966.
Security strips and labels on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.
Do not plug the unit into a power outlet until the 3M service representative has completed the wiring.
When items are returned, the security strips can be resensitized. Improperly resensitized items will not alarm when passed through the detection system.


Installation · Description/Characteristics · Model 966

Select the Sensitize mode.
Select the Desensitize mode.
Place the spine of a protected book or a compact disc on the flat surface of the Model 966.
Place the spine of a protected book or a compact disc on the flat surface of the Model 966.
Slide the item to be sensitized in the direction of the arrow while gently touching the item against the vertical portion of the unit.
Slide the item to be desensitized in the direction of the arrow while gently touching the item against the vertical portion of the unit.
As the item passes the optical trigger, an audible signal (thump) will indicate that the 3M Tattle-Tape security strip has been sensitized.
As the item passes the optical trigger, an audible signal (thump) will indicate that the 3Mt Tattle-Tapet Security Strip has been desensitized.
To confirm that the security strip has been properly sensitized, move the item to the center of the unit and the orange verifier light should turn on. If the verifier light does not turn on, then the item is not protected with a 3M Tattle-Tape security strip.
The orange verifier light will also turn off, confirming that the security strip has been properly desensitized.
To ensure that items are properly desensitized, do not place more than one item at a time on the Model 966.
To ensure that items are properly sensitized, do not place more than one item at a time on the Model 966.



Incorrect Methods of Sensitizing and Desensitizing

Verifying that materials are protected with 3Mt Tattle-Tapet Security Strips
No desensitizing or resensitizing
When the VERIFIER switch is in the ON position, the verifier light will identify which items in your collection are protected with 3Mt Tattle-Tapet security strips.
resensitize any strip.
The Model 966 fails to operate or “thump”.
To verify that an item is protected, resensitize the item as described earlier.
Problem: The Model 966 is not connected to a working power outlet.
Make sure the Sensitize/Desensitize switch is in the SENSITIZE position.
Solution: Plug the Model 966 into a working power outlet.
Place the item in the center of the Model 966 with the item gently touching the vertical portion of the unit.
Problem: The optical sensor area may have accumulated dust.
If the item is protected, the verifier will light. If the verifier does not light, then you will want to install a 3M Tattle-Tape security strip to protect the item.
Solution: Clean this area by blowing or brushing dust from the optical sensors.
! Caution To reduce the risk of electrical shock, do not use liquids to clean the optical sensor.



Resetting the circuit breaker
The Model 966 will not operate if the circuit breaker is open.
S Reset the circuit breaker on the back of the Model 966 one time.
S If the Model 966 does not operate correctly after resetting the circuit breaker one time, call 3M service at 1-800-328-0067.
Troubleshooting · Optical Sensor

Security Strips Used with the 3Mt Bookcheck Model 966
Typical Items Used with the 3M Model 966 In-Counter Bookcheck
3Mt Tattle-Tapet Security Strips
B2
DCD-2
Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least 6 inches [150 mm] away from the 3M Model 966 surface to prevent magnetic damage.
Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a grease cutting cleaner. Rub on the surface until clean and wipe dry.
Security Strip Storage Conditions
Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

4.10 3Mt On-Counter Desensitizer Model 763 (For Use With Recorded Magnetic Media)
To desensitize security strips:
Draw the marked item across the surface of the Model 763. Make sure the strips are against the back or horizontal surface of the unit. Place video tapes against the back of the unit as shown in the following example.
The 3Mt On-Counter Desensitizer Model 763 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to audio and video cassettes, and prepackaged computer software.

This device is not intended to desensitize security strips which have been applied directly to computer software, as the disks may be damaged.
Security strips on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.

Place audio tapes on the horizontal surface of the unit as shown in the following example.

The 3M Model 763 is a moveable, non-electric, on-counter device which requires no installation. However, the 3M Model 763 should be used and stored away from areas which are readily accessible to customers.
Only one pass is necessary to fully desensitize a security strip.
To avoid damage to credit cards or computer software, do not permit credit cards or computer disks to make direct contact with the 3M Model 763.
Operating Instructions · Description/Characteristics · Installation

Security Strips Used with the 3Mt Desensitizer Model 763
Typical Items Used with the 3M Desensitizer Model 763
3Mt Tattle-Tapet Security Strips
DVM-1
DSA-1
Security strips should be applied only to surfaces which are flat, clean, dry, and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
To avoid damage to credit cards or computer software, do not permit credit cards or computer disks to make direct contact with the 3M Model 763.
Computer software disks should be enclosed in a box or case to keep disks at least 1/4I (6 mm) from the 3M Model 763 surface.
The 3M Model 763 should be used and stored away from areas which are readily accessible to customers.
Security Strip Storage Conditions
Store security strips at 50_ -- 90_F (10_ -- 32_C) and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security system to be defeated.

4.11 3Mt On-Counter Resensitizer Model 764 (Not For Use With Recorded Magnetic Media)
sliding the printed material. Connect the device to an AC power outlet. For an AC voltage range of 100 -- 120 VAC, use a 120 VAC 60 Hz unit, and for an AC voltage range of 200 -- 240 VAC, use a 220 VAC 50 Hz unit.
The Model 764 is a stand-alone on-counter resensitizer. It is used to resensitize 3Mt Tattle-Tapet Security Strips that have been applied to books, magazines, and other print media or to compact disks. Properly resensitized strips will set off an alarm when carried through a 3Mt Detection System. The Model 764 is powered from an AC power outlet.
System placement relative to interfering objects:
Magnetic Material:Keep all MAGNETICALLY
RECORDED MATERIALS, audio and video cassettes, and computer disks at least 6 inches [150 mm] from the M764 Resensitizer.
Computers (CRT) Keep all computers (CRTs) at least
36 inches [914 mm] from the M764 Resensitizer.
Physical:
Bright Lights: Keep the Model 764 out of direct sunlight or other bright light. A change in the amount of light detected by the unit may cause false triggering.
Depth: 5.5 in. [140 mm] Width: 12.25 in. [311 mm] Height: 4.38 in. [111 mm] Weight: 14.3 lbs. [6,5 kg] Shipping Weight: 17.0 lbs. [7,7 kg]
To avoid damage to credit cards or computer software: Do not attempt to resensitize security strips which have been applied directly to computer software. Do not permit credit cards or computer software disks to make direct contact with the 3M Model 764.
Resensitizing Books or Other Print Media
Slide the marked item from right to left along the front of the Model 764 as shown below. The spine of the marked item must be in contact with the front surface.

The Model 764 is a stand-alone on-counter device. It can be set on any non-metallic table or cart top. The Model 764 may produce audible noise and/or vibration if placed within 0.8 inches [20 mm] of metal objects or surfaces. A mounting base option is available that eliminates this situation.
For proper operation, the printed material must be moved across the front of the Model 764, so there must be adequate space on either side of the device for

Resensitizing Compact Disks (CDs)
The procedure for resensitizing CDs is the same as for books, except: the CD must be positioned upright as shown below and two passes must be made.




Spine of Material not against Model 764

If the indicator light will not turn on during a proper pass, check the power connection for the Model 764. If the power connection is good, disconnect the power cord from the unit, pull out the fuse holder and check the fuse. A spare fuse is provided with each new Model 764. This unit is not otherwise operator serviceable.



Typical Items Used with the 3M On-Counter Resensitizer Model 764
In the U.S., the Model 764 is not serviced at the customer site. If a unit fails, it is replaced. When the replacement unit is received, the user packages the failed unit in the shipping carton and returns it to 3M. For assistance or more information on this program, please call the 3M National Service Center, 1 (800) 328-0067.
International users should call the 3M subsidiary in their area for information on local service.
Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least 6 inches [150 mm] away from the 3M Model 764 surface to prevent magnetic damage.
Security Strips Used with the 3Mt On-Counter Resensitizer Model 764
3Mt Tattle-Tapet Security Strips
B2
Security Strip Storage Conditions
Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.
Store security strips in a clean area and out of direct sunlight. Rotate stock.
Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a grease cutting cleaner. Rub on the surface until clean and wipe dry.

4.12 3M t Model 494 Locking Exit or Entrance Gate
Problem: Gate will not lock or remains locked. Gate closes too quickly (less than 4 seconds) or too slowly (more than 7 seconds).
The 3M Model 494 is designed to restrain patrons during an alarm. Gates are shipped from the factory to open with a clockwise rotation but may be modified to open with a counterclockwise rotation.
Solution: Place service call.
Problem: Gate arm does not return to the correct closed position (perpendicular to the gate base).
The locking mechanism is controlled by an alarm signal and power from the detection system.
When a strip is detected in the detection system and an alarm is created, the exit gate will lock in the closed position blocking patron travel through the exit corridor. The gate remains locked for the alarm period. If the gate is locked during an emergency, the gate arm can be forced open with a force of 15 -- 25 lbs. [6,8 -- 11,3 kg].
Solution:
Gates are not available on the Detection System Model 3500.

Force Gate Arm to Correct Position
Gate Arm Stops Here
Locking exit gates may be installed on either side of the detection system. For single corridor systems, the gate box may be located at the end of either panel. For dual corridor systems, two gates are required and the gate boxes must be located at the ends of the two outside panels.
The locking exit gate is designed to be installed by 3M factory trained service personnel.


Force Gate Arm to Correct Position
Gate Arm Stops Here

4.13 3Mt SelfCheckt System Model 5210
S Multiple Book Detection prevents more than one item from being checked out on the same bar code
S Built-in photocells keep patrons from substituting materials
The system emulates the same procedures to process materials that librarians use. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip — all in a matter of seconds.
S Advanced technology raster laser scanner reads the entire bar code area, enabling it to read even worn codes
S Only desensitizes books when approved by the host circulation system
S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of transaction
If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.
S Simple to install wherever floor traffic demands
S Can be programmed with a wide variety of messages and instructions to fit most library situations
The 3M selfcheck system is compatible with many automated circulation systems.
S PIN numbers can be added for security against misuse of lost or stolen library cards
The system also features menus which allow you to make changes in a few minutes. You can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.
S Overall design and neutral beige color blends well into any library decor
The system operates much like automatic teller machines. For details, refer to the Operating Guide for the Model 5210.
S Automates library checkout, freeing staff time for other important tasks
The following diagram illustrates the components that the patron uses in the 3M selfcheck system.
S Built-in 3M Tattle-Tape security strip detection ensures that library security is not compromised
S Full-color graphics and user-friendly prompts are easy to follow

Scanner to read bar codes
Color Monitor displays graphic instructions to patrons
Red scanning area where patrons place library cards and library materials to be scanned
Magnetic Card Reader (optional)
Printer for due date receipt

4.14 3Mt SelfCheckt System Model 5220
S Full-color graphics and user-friendly prompts are easy to follow
S Multiple Book Detection prevents more than one item from being checked out on the same bar code
The SelfCheck system emulates the procedures used by librarians to process library materials. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved library patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip — all in a matter of seconds.
S Built-in photocells keep patrons from substituting materials
S Advanced technology raster laser scanner reads the entire bar code area, enabling it to read even worn codes
S Only desensitizes books when approved by the host circulation system
S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of a transaction
If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials are on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.
S Simple to install wherever floor traffic demands
S Can be programmed with a wide variety of messages and instructions to fit most library situations
The 3M selfcheck system is compatible with many automated circulation systems.
The system also features menus which allow librarians to make changes in a few minutes. They can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.
S PIN numbers can be added for security against misuse of lost or stolen library cards
S Overall design and neutral beige color blends well into any library decor
The system operates much like automatic teller machines. For details, refer to the Operating Guide for the Model 5210/5220.
S Automates library checkout, freeing staff time for other important tasks
S Built-in 3M Tattle-Tape security strip detection ensures that library security is not compromised
The following diagram illustrates the components that the patron uses in the 3M selfcheck system.
Scanner to read bar codes

Color Monitor displays graphic instructions to patrons
Scanning area where pa- trons place library cards and library materials to be checked out.
Printer for due date receipt

4.15 3Mt SelfCheckt System Model 6210
S Multiple Book Detection prevents more than one item from being checked out on the same bar code
S Built-in photocells keep patrons from substituting materials
The SelfCheck system Model 6210 emulates the procedures used by librarians to process library materials. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved library patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip — all in a matter of seconds.
S Advanced technology laser scanner reads the entire bar code area, enabling it to read even worn codes
S Only desensitizes books when approved by the host circulation system
S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of a transaction
If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials are on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.
S Simple to install wherever floor traffic demands
S Can be programmed with a wide variety of messages and instructions to fit most library situations
The 3M selfcheck system is compatible with many automated circulation systems.
S PIN numbers can be added for security against misuse of lost or stolen library cards
The system also features menus which allow librarians to make changes in a few minutes. They can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.
S Overall design and light gray color blends well into any library decor
The system operates much like automatic teller machines. For details, refer to the on-line Operating Guide for the Model 6210.
S Automates library checkout, freeing staff time for other important tasks
The following diagram illustrates the components that the patron uses in the 3M selfcheck system.
S User-friendly prompts and graphics are easy to follow

Color monitor displays graphic instructions to patrons
Scanner to read bar codes
Receipt printer for due date receipt
Magnetic card reader (optional)
Video cassette unit to process VHS video tapes
Scanning area where patrons place library cards and library ma- terials to be scanned

4.16 3M t SelfCheck t System Model 4210
S Multiple Book Detection prevents more than one item from being checked out on the same bar code
S Built-in photocells keep patrons from substituting materials
The SelfCheck system Model 4210 emulates the procedures used by librarians to process library materials. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved library patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip - all in a matter of seconds.
S Advanced technology laser scanner reads the entire bar code area, enabling it to read even worn codes
S Only desensitizes books when approved by the host circulation system
S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of a transaction
If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials are on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.
S Simple to install wherever floor traffic demands
S Can be programmed with a wide variety of messages and instructions to fit most library situations
The 3M selfcheck system is compatible with many automated circulation systems.
S PIN numbers can be added for security against misuse of lost or stolen library cards
The system also features menus which allow librarians to make changes in a few minutes. They can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.
S Overall design and light gray color blends well into any library decor
The system operates much like automatic teller machines. For details, refer to the on-line Operating Guide for the Model 4210.
S Automates library checkout, freeing staff time for other important tasks
The following diagram illustrates the components that the patron uses in the 3M selfcheck system.
S User-friendly prompts and graphics are easy to follow
Scanner to read bar codes

Magnetic card reader (optional)
Cradle Scanning area where patrons
place library cards and
Receipt printer for due date receipt
materials to be scanned
Video checkout unit - to process VHS video tapes
Keypad Black & white monitor displays graphic instruc- tions to patrons
Description/Characteristics · Operating Instructions · Features and Benefits

4.17 3M t Staff Workstation Model 995
The staff workstation is designed to desensitize and resensitize the following 3Mt Tattle-Tapet Security Strips:
The 3Mt Staff Workstation Model 995 emulates the same processes the library staff follows to check in or out library items. The Model 995 is connected to an existing library terminal and consolidates several processing tasks.
The desensitizing and resensitizing deck can be surface or flush mounted.
S Reduces item handling S Enhances library security S No additional software S Compatible with most existing workstations S Checks items in or out S Magnetic media safe S Security sensitizing or desensitizing S Security verification S Scanner disabling S In or on counter installation
A scanner and a keyboard wedge are included with the Model 995 to scan item bar codes. This replaces scanning with a hand-held scanner, using a light pen, or entering the number on the keyboard.
For processing non-magnetic media, electronics in the Model 995 eliminate the need for separate resensitizing and desensitizing accessories.
With the flip of a switch, the operator can process recorded magnetic media such as audio cassettes, video cassettes, or computer software. Magnetic media may be processed by using the Model 995 to record the transaction in the library circulation system and an appropriate resensitizer or desensitizer to sensitize or desensitize the strip.
This system operates similar to the common check in and check out processes. For details, refer to the Staff Workstation Model 995 Operator’s Manual.


Blank Page

Section 5. 3Mt Tattle-Tapet Security Strips Used with the 3Mt Detection System
To determine the recommended 3M stripping procedures for each strip type, please refer to the page(s) which describe the specific strip you are using.
3M offers a complete line of 3Mt Tattle-Tapet Security Strips which will allow you to protect a variety of items. Each of the security strips which can be used with the 3Mt Detection Systems is described in this section. The strips provide maximum protection and are most effective when 3M marking procedures are followed.
Security Strips Used with the 3M Detection Systems
B1 5-3 B2 5-5 DAC-1 5-7 DCD-2 5-9 DVM-1 5-11
Stripping Procedure · Description/Characteristics · Security Strips Page

5.1 Print Media Protection — 3M t Tattle-Tape t Security Strips: B1

The 3Mt B1 Security Strip is a security strip which may be secured inside the spine of a book.
Security strips on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.
The 3M B1 security strips should be applied and stored away from areas which are readily accessible to patrons.
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.


Installation in Books · Description/Characteristics · Security Strip Application

Desensitizers Used with 3Mt Tattle-Tapet B1 Security Strips
Push the bayonet between the book cover and the binding.
3Mt On-counter Model 930
3Mt Bookchecks Models 435, 950 and 955
Pull the bayonet through the book, stopping when the security strip disappears.
3Mt Bookcheck Model 966
3Mt In-counter Model 2004

Resensitizers Used with 3M Tattle-Tape B1 Security Strips
3M Bookchecks Models 435, 950 and 955
3M Bookcheck Model 966
3Mt Handheld Resensitizer Model 951
3Mt On-counter Resensitizer Model 764
Typical Items Marked with 3M Tattle-Tape B1 Security Strips

Security Strip Storage Conditions
Store security strips at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.
Keep security strips in a clean area and out of direct sunlight. Rotate stock.
Store the security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Hardcover books

5.2 Print Media Protection — 3M t Tattle-Tape t Security Strips: B2
The 3Mt B2 Security Strips are designed to be placed between the pages of books or magazines.
Avoid pages where the book opens naturally.
Do not open the book wide enough that it will open to this page again.
Security strips on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.

The 3M B2 security strips should be applied and stored away from areas which are readily accessible to patrons.
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

Installation in Books · Description/Characteristics · Security Strip Application

Desensitizers Used with 3M Tattle-Tape B2 Security Strips
3Mt On-counter Model 930

3Mt Bookchecks Model 435, 950 and 955
3Mt Bookcheck Model 966
3Mt In-counter Model 2004
Resensitizers Used with 3M Tattle-Tape B2 Security Strips
3M Bookchecks Models 435, 950 and 955
3M Bookcheck Model 966
3Mt Handheld Resensitizer Model 951
3Mt On-counter Resensitizer Model 764
Typical Items Marked with 3M Tattle-Tape B2 Security Strips

Security Strip Storage Conditions
Store security strips at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.
Keep security strips in a clean area and out of direct sunlight. Rotate stock.
Store the security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Paperback books · Hardcover books · Periodicals

5.3 Audio Cassette Protection — 3M t Tattle-Tape t Security Strips: DAC-1

The 3Mt Tattle-Tapet DAC-1 Audio Cassette Security Strip and cover label are designed to be applied directly on audio cassettes.
Once applied, discreet protection and full circulation of audio cassettes is provided for the life of the marked item.
Security strips on protected cassettes must be properly desensitized so the cassettes can be carried through the detection system without causing an alarm.

The 3M Tattle-Tape DAC-1 security strips should be applied and stored away from areas which are readily accessible to patrons.
Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

Marking Audio Cassettes · Description/Characteristics · Security Strip Application

Desensitizers Used with 3Mt Tattle-Tapet DAC-1 Security Strips

3Mt On-counter, magnetic media Model 2001
3Mt Handheld, magnetic media Model 766
3Mt On-counter, magnetic media Model 763
Resensitizers Used with 3M Tattle-Tape DAC-1 Security Strips
3M On-counter, magnetic media Model 2011
Typical Items Marked with 3M Tattle-Tape DAC-1 Security Strips
Security Strip Storage Conditions
Store security strips at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.
Keep security strips in a clean area and out of direct sunlight. Rotate stock. Use security strips within 2 years of purchase to assure maximum adhesion of strip and cover label.
Store the DAC-1 security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized, resulting in poor detection. If this should happen, the strips may be fully resensitized prior to use.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Audio cassettes

5.4 Compact Disc Protection — 3M t Tattle-Tape t Security Overlay: DCD-2

The 3Mt Tattle-Tapet DCD-2 Compact Disc Security Overlay is designed to be applied directly on CDs and CD-ROMs. The security strip and overlay are combined to simplify installation.
Once applied, protection and full circulation of CDs and CD-ROMs is provided for life of the marked item.
Security strips on protected compact discs must be properly desensitized so the compact discs can be carried through the detection system without causing an alarm.

The 3M Tattle-Tape DCD-2 overlay should be applied and stored away from areas which are readily accessible to patrons.
DCD-2 overlays should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the overlay.


Description/Characteristics · Security Strip Application · Marking Compact Discs

Desensitizers Used with 3Mt Tattle-Tapet DCD-2 Overlay
Security Overlay Storage Conditions
Store security overlays at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.
3Mt On-counter Model 930
3Mt Bookchecks Models 435, 950 and 955
Keep security overlays in a clean area and out of direct sunlight. Rotate stock. Use security strips within 2 years of purchase to assure maximum adhesion of overlay.
3Mt Bookcheck Model 966
3Mt Handheld Model 766 (must contact overlay)
Resensitizers Used with 3M Tattle-Tape DCD-2 Overlay
Store the security overlays at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.
3Mt Handheld Resensitizer Model 951
3M Bookchecks Models 435, 950 and 955
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
3M Bookcheck Model 966
3Mt On-counter Resensitizer Model 764
Typical Items Marked with 3M Tattle-Tape DCD-2 Overlay
Compact discs · CD-ROMs

5.5 Video Cassette Protection — 3M t Tattle-Tape t Security Strips: DVM-1

The 3Mt Tattle-Tapet DVM-1 Video Cassette Security Strip and cover label are designed to be applied directly on video cassettes.
Once applied, discreet protection and full circulation of video cassettes are provided for the life of the marked items.
Security strips on protected cassettes must be properly desensitized so the cassettes can be carried through the detection system without causing an alarm.
The 3M Tattle-Tape DVM-1 security strips should be applied and stored away from areas which are readily accessible to patrons.

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.
Description/Characteristics · Security Strip Application · Marking Video Cassettes

Desensitizers Used with 3Mt Tattle-Tapet DVM-1 Security Strips

3Mt On-counter, magnetic media Model 2001
3Mt Handheld, magnetic media Model 766
3Mt On-counter, magnetic media Model 763
Resensitizers Used with 3M Tattle-Tape DVM-1 Security Strips
3Mt On-counter, magnetic media Model 2011
Typical Items Marked with 3M Tattle-Tape DVM-1 Security Strips
Compact disc jewel cases
Security Strip Storage Conditions
Store security strips at 50_ -- 90_F
[10_ -- 32_C] and at 20 -- 70% relative humidity.
Keep security strips in a clean area and out of direct sunlight. Rotate stock. Use security strips within 2 years of purchase to assure maximum adhesion of strip and cover label.
Store the security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.
Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.
Video cassettes · Maps · Documents

Blank Page

Section 6. Training Your Staff
6.1 Operator’s Manual
This manual contains all of the information necessary to operate your 3M Library Security System, as well as supplemental information on handling alarms, ordering supplies, and training your staff. It also contains important information about security strips and circulation accessories.
A key element of any media loss prevention effort is a successful staff training program. Your 3Mt Library Security System will be much more effective with the active cooperation and participation of your entire library staff. We recommend that you periodically conduct formal training sessions, including the following elements to ensure its success:
Library personnel should be familiar with the manual and where to locate it so they can refer to it when necessary.
6-1 Familiarization with the Operator’s Manual
6--2 View 3M Materials Flow Management Customer Training Video
The 3M Materials Flow Management Customer Training Video is provided along with the 3M Library Security System. We recommend you view this video prior to familiarizing yourself with other training information in this section.
6-3 Hands-on practice marking materials with security strips and labels and desensitizing and resensitizing security strips
6-4 Review of your library’s security policies
6-5 What to do when the alarm sounds
6-6 System Alarm Log
6-7 Addressing patron concerns

6.3 Hands-on Practice
6.5 What To Do When The Alarm Sounds
After reviewing the Operator’s Manual, your staff should get some actual hands-on experience in using the 3M Materials Flow Management products. We suggest you start by demonstrating the proper techniques for each stripping procedure. You may wish to conduct the actual practice as follows:
S Have your staff review the 3M Materials Flow Management Customer Training Video included in your customer training kit. The video includes an index and running time clock for easy review of specific sections of the video.
Sooner or later, it’s bound to happen. The audible alarm goes off. In multiple corridor systems, the light at the top of the panel will indicate in which corridor the alarm occurred. What you and your staff do in response to the alarm will depend on your library’s policy and the laws in your community. Always follow your library’s specific procedures. 3M offers these guidelines as a suggested supplement:
S Set up your circulation accessories on a table along with security strips and a few bayonets.
S Let each staff member practice installing the security strips that you use:
B1 Strips -- in the spine of
books B2 Strips -- in the gutter of
First, don’t panic. Remain calm and courteous. You can’t be positive that the person who triggered the alarm is stealing. Never accuse anyone of theft by word, by facial expression, or by tone of voice. The alarm may have been triggered accidentally, so always respond in a positive, non-threatening manner.
books DVM-1 Strips -- on video tapes DCD-2 Overlays -- on compact discs DAC-1 Cassette -- on audio cassettes Strips
S Let each staff member practice desensitizing and resensitizing materials with the appropriate circulation accessories.
Before practicing how to respond to alarms, your staff should be familiar with your library’s security policies as they relate to theft of materials. Your policy should be put in writing and kept in your training kit in addition to any procedures you already follow to keep your staff informed of security measures. It is particularly important for staff members to know what procedures your library follows when theft is suspected or when it is necessary to contact a local law enforcement agency.
A critical phase of staff training concerns the proper steps to take when the security system alarm sounds. The value of tact and courtesy when handling this delicate situation cannot be overemphasized. Your staff members should receive as much preparation as possible to make them feel comfortable. Only then will they be likely to deal successfully with patrons who activate the alarm.

The library staff person mistakenly neglects to desensitize a marked item when checking out the patron’s materials, or the patron accidentally removes marked materials from the library.
The detection system is virtually free of false alarms. Occasionally the detection system may alarm and the staff will find that the patron does not have unauthorized library materials. The patron may have carried items with active strips into the library. “Unwanted alarms” are alarms caused by active security strips on items carried into the library. If the following items have active security strips, they may cause unwanted alarms:
After asking the patron to return to the counter, a typical response might be, “Excuse me, did I forget to check out one of your items?” — or — “Did you perhaps pick up one of the library’s books with your own things?” These are courteous questions, and they don’t accuse the patron of theft. Be sure to smile and ask the questions in a friendly, non-threatening manner.
S Books from another library or book store
S Audio and video cassettes from video rental and music stores
Process and desensitize all items again. If you discover an item that hasn’t been properly checked out, never accuse the patron of stealing. Simply act as if the error was an oversight — it more than likely was. If the patron causes the alarm to sound again, follow the policy that your library has established for possible theft of materials.
S Other items from retail stores
Other security system users may check out, lend, or sell protected items without desensitizing the security strips. These items will cause unwanted alarms as the patron enters or exits the library. Unwanted alarms will cause concern and added work for the library staff. Unwanted alarms are generally infrequent and will vary depending on the patrons and on the proximity of your library to locations that are releasing materials containing active security strips.
If a patron denies having any library materials after sounding the alarm, follow your library’s policy for theft.
Because it is not possible to distinguish between unwanted alarms and alarms with potential book loss, all responses to alarms must be consistent and follow your management policies. If patrons see no response to alarms, the detection system becomes less effective. When you decide that an active strip on an item from outside your library caused an alarm, follow these steps:
If a patron bolts and runs out of the library after sounding the alarm, follow your library’s policy for theft.
Responding to alarms is a sensitive situation, but can be handled confidently and effectively as long as your library has established procedures AND your staff has been fully trained in following them.
Many patrons will learn from the experience and will not carry items that may cause alarms into the library.

6.6 System Alarm Log
6.7 Addressing Patron Concerns
The System Alarm Log is used to keep a record of alarms that occur.
If your patrons express concern about the effect of the 3Mt Detection System on pacemakers, hearing aids, recorded magnetic media, you can respond that 3M researchers (in conjunction with the manufacturers of these items) have conducted extensive tests on 3M detection systems and have found them to be perfectly safe. The magnetic signal used by the detection panels to detect sensitized 3Mt Tattle-Tapet Security Strips is no stronger than that of an ordinary kitchen blender or a hair dryer.
For each alarm, record the information on the log. Keeping this log up-to-date provides a key tool for monitoring system activity. An up-to-date alarm log provides useful information for your management and your 3M service representative.

1. Test 2.Upon entering 3.Failure to desensitize 4. Undetermined 5. Real alarm

(1) Reason for Alarm:
Date Time Patron · Alarm

6.8 Cleaning Instructions
S Steps 3 through 6 are for washing the fan filter. Instead of washing the filter, it may be vacuumed without removing the grille. Washing is preferred because it results in a more thorough cleaning.
Turn off the security system prior to using liquid cleaners. Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a common household grease-cutting liquid cleaner. We suggest a monthly cleaning to retain the best equipment appearance.
Photocell Lens and Reflector
At least once a month, wipe the photocell lens and reflector with a soft cloth dampened with water.

Over time, areas on accessories that come in constant contact with adhesive-backed tapes and labels will accumulate a build-up of adhesive. To remove adhesive build-up, clean the surface with a cloth dampened with rubbing alcohol (ethyl or isopropyl).
Fan Filter on Electronics Chassis
At least once every six months, clean the fan filter as follows:

6.9 Troubleshooting Guide

No alarm, no patron count, no diagnostic code in display window.
No power at wall outlet. Reset facility circuit breaker.
System unplugged. Plug in and wait two minutes for full operation.
System circuit breaker tripped. Reset the circuit breaker no more than three times. Call 3M Service if problem persists.
System failure. Place service call.
No alarm, diagnostic code 1, 2, 3, 4, 5, or 6 in window.
System failure. Place service call. Code number will be needed.
No alarm, patron count in window.
Strip desensitized. Test system with another marked object with a sensitized strip.
Model 2301, 2302 · Problem Cause Action

Infrequent unwanted alarms.
Miscellaneous metallic objects. Infrequent, unwanted alarms are considered acceptable.
Protected material from other library or retail store.
Identify material that caused alarm.
Failure to desensitize strip properly. Check operator training procedures.
Frequent (daily) unwanted alarms.
Failure to desensitize strip properly. Follow correct check-out procedures outlined in 3M literature. Check operator training procedures.
Metallic object located too close to system.
Remove, maintain a minimum distance of 3 feet.
System failure. Place service call. Code number, if any, will be needed.
Reduced coverage, no alarm.
Metallic object located too close to system.
Remove, maintain a minimum distance of 3 feet.
Incomplete walk-through test. Retest by walking completely through the corridor. The light beam between the photocell and the reflector in the corridor must be interrupted.
Strip not detected. Retest marked object.
System failure. Place service call. Code number will be needed.
Diagnostic code 7 in window.
Metallic object located too close to lattice. Examples: metal window or door frames, desks, counters, shelves, waste baskets, etc.
Move metal object or system until minimum distance is approximately 3 feet.
Diagnostic code 8 in window.
Excessive electrical/electronic interference, generally caused by devices such as computers, CRTs, copiers, electronic fluorescent lights.
Decrease interference from device: Move device farther away from system. Turn device off. Use device with lower emissions. Shield device.
Problem Cause Action

6.10 Troubleshooting Guide
No alarm, no patron count, no red power indicator on Electronic Enclosure.
No power at receptacle. Reset facility circuit breaker.
Power cord disconnected at receptacle.
Plug power cord in receptacle.
System fuse open. Replace fuse in power entry connector.
Power turned off at Electronics Enclosure.
Turn key switch to ON.
System failure. Place service call. (1-800-328-0067)
No alarm, no patron count, power indicator ON.
Processor requires reset. Turn key switch OFF, wait 5 seconds, then turn switch ON.
System failure. Place service call. (1-800-328-0067)
Model 3501, 3502 · Problem Cause Action

No alarm, patron counter works.
Strips in book desensitized or missing.
Resensitize books, or install Tattletape in book.
System failure. Place service call. (1-800-328-0067)
Metal objects too close to panel. Move all metal to minimum distance of 18 inches from the panels.
Unwanted alarms. Protected material from other library/retail store.
Identify material that caused alarm.
Failure to desensitize marker properly.
Check desensitizing process and training.
Miscellaneous metallic objects. Infrequent unwanted alarms from some metal objects are possible.
System failure. Place service call. (1-800-328-0067)
Reduced coverage, no alarm, patron counter works.
Metal objects too close to panel. Move all metal objects to a minimum distance of 18 inches from panels.
Electrical interference. Remove possible sources of electrical interference such as computers, copiers, TVs, and electronic devices.
Incomplete walk-through test. Test the system by walking completely through just as a patron must.
Books not properly resensitized. Resensitize book, check sensitizing method and staff training.
System failure. Place service call. (1-800-328-0067)
Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor.
Metal objects too close to panel. Move all metal objects to a minimum of 3 feet from the panel.
Marked book or strips too close to panel.
Move marked books to a minimum of 3 feet from the panel.
Electrical interference. Eliminate source of interference.
System failure. Place service call. (1-800-328-0067)
Problem Cause Action

6.11 Troubleshooting Guide
No alarm, no code in window.
No power at wall outlet. Reset facility circuit breaker.
Panel unplugged. Plug in and wait five minutes for full operation.
System circuit breaker tripped. Reset the circuit breaker no more than three times. Call 3M Service if problem persists.
Power turned off at system panel. Turn key switch to ON.
System failure. Place service call.
No alarm, code 3 in window.
Dirty fan filter. Clean fan filter.
System failure. Place service call.
No alarm, code 5 in window.
Metal objects such as carts of trash cans next to system.
Remove interfering objects. Pull power cord at wall plug. Wait ten seconds. Reinsert plug and wait five minutes for full operation.
No alarm, code 6 in win- dow.
Detection reduced due to presence of metal objects, computers, cash regis- ters, or electronic device next to sys- tem.
Check area directly next to panels. Move objects away. Retest system.
Model 3801, 3802 · Problem Cause Action

No alarm, code 1, 2, 4, 7 or 8. System failure. Place service call. Code number will be needed.
No alarm, patron count in window.
Marker deactivated. Test system with another marked object with a sensitized strip.
Infrequent unwanted alarms.
Miscellaneous metallic objects. Infrequent, unwanted alarms are considered acceptable.
Protected material from other library or retail store.
Identify material that caused alarm.
Failure to desensitize marker properly.
Check operator training procedures.
Frequent (daily) unwanted alarms.
Failure to desensitize marker properly.
Follow correct check-out procedures outlined in 3M literature. Check operator training procedures.
Photocell or reflector lens dirty. Clean with soft cloth and water.
System failure. Place service call. Code number will be needed.
Reduced coverage, no alarm.
Metallic object located too close to system.
Remove, maintain a minimum distance of 2 feet.
Incomplete walk-through test. Retest by walking completely through the corridor. The light beam between the photocell and the reflector in the corridor must be interrupted.
Marker not detected. Retest marked object.
No alarm, code 9 in window.
System is in warm-up mode. Wait approximately 1 minute.
Problem Cause Action

6.12 Ordering Supplies
With NetscapeR, version 1.1 or later or MicrosoftR Internet Explorert, version 2.0 or later in the U.S., you can place service requests over the Internet. 3M will send you an automated confirmation of your request and then another confirmation when you are scheduled for service. The Internet service address is:
Be sure to budget annually for any supplies you might need. You should also budget for your Service Agreement renewal each year so that you are assured of getting the most cost-effective service for your 3Mt Detection System.
Remember . . . only when all of your library materials are marked with 3Mt Tattle-Tapet Security Strips, are you effectively protecting your materials from loss and assuring that all of them are available to your patrons when they’re needed.
To renew your supply of 3M Tattle-Tape strips and bayonets, simply call our customer service number:
In U.S.: 1/800-328-0067 (toll-free). Press 2 when instructed to do so.
When you call for service, please have the following information available:
a. Is the malfunction in the detection system or desensitizer/resensitizer?
You can use this number if you want to order additional circulation accessories, detection equipment or other supplies.
b. Symptoms of the problem: poor or no detection; system alarms for no apparent reason; Bookcheck will not desensitize/resensitize; light does not work, etc.
To renew your Service Agreement, simply follow the instructions on the renewal notice you receive in the mail 90 days prior to the expiration of your current Service Agreement.
c. What is the diagnostic code indicated in the Status Display Window located on the side of the detection panel?
3M has a nationwide service network to help in the event you experience any difficulties with your 3M detection system. Simply call our service number:
The service representative will discuss the problem with you and attempt to solve it on the telephone. If a service call is necessary, a 3M service technician will be quickly dispatched to your library.
In U.S.: 1/800-328-0067 (toll-free, 24 hours a day). Press 1 when instructed to do so.
Français 1-800-567-3193 · Français 1-800-567-3193

Blank Page

Section 7. Service
To request service, call the 3M National Service Center.
Press 1 when instructed to do so.
Provide system model and serial numbers.
Model Number Serial Number

Blank Page

that, in 3M’s sole judgment, the performance or reliability is adversely affected thereby, or which is subjected to accident, misuse or neglect.
THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, indirect, or consequential, arising out of the sale, use, or misuse of 3M Library System products, or the user’s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE.
3M warrants that the 3Mt Library Security System will be free of defects in material and manufacture for a period of 90 days from the date of installation by 3M. Provided the system has been properly installed, operated, and maintained by purchaser, 3M will, at 3M’s option, repair, replace or refund the purchase price of such quantity of product determined to be defective. This warranty shall not apply to any system or component which has been repaired or modified by persons not authorized by 3M so
Statements or recommendations not contained herein shall have no force of effect unless in an agreement signed by an authorized representative of 3M. 3M reserves the right to make any changes in the design or construction of its products without obligation in respect to products previously sold and delivered.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No alarm, no patron count, no diagnostic code in display window. | No power at wall outlet. | Reset facility circuit breaker. | p.81 |
| No alarm, no patron count, no diagnostic code in display window. | System unplugged. | Plug in and wait two minutes for full operation. | p.81 |
| No alarm, no patron count, no diagnostic code in display window. | System circuit breaker tripped. | Reset the circuit breaker no more than three times. Call 3M Service if problem persists. | p.81 |
| No alarm, no patron count, no diagnostic code in display window. | System failure. | Place service call. | p.81 |
| No alarm, diagnostic code 1, 2, 3, 4, 5, or 6 in window. | System failure. | Place service call. Code number will be needed. | p.81 |
| No alarm, patron count in window. | Strip desensitized. | Test system with another marked object with a sensitized strip. | p.81 |
| Infrequent unwanted alarms. | Miscellaneous metallic objects. | Infrequent, unwanted alarms are considered acceptable. | p.82 |
| Infrequent unwanted alarms. | Protected material from other library or retail store. | Identify material that caused alarm. | p.82 |
| Infrequent unwanted alarms. | Failure to desensitize strip properly. | Check operator training procedures. | p.82 |
| Frequent (daily) unwanted alarms. | Failure to desensitize strip properly. | Follow correct check-out procedures outlined in 3M literature. Check operator training procedures. | p.82 |
| Frequent (daily) unwanted alarms. | Metallic object located too close to system. | Remove, maintain a minimum distance of 3 feet. | p.82 |
| Frequent (daily) unwanted alarms. | System failure. | Place service call. Code number, if any, will be needed. | p.82 |
| Reduced coverage, no alarm. | Metallic object located too close to system. | Remove, maintain a minimum distance of 3 feet. | p.82 |
| Reduced coverage, no alarm. | Incomplete walk-through test. | Retest by walking completely through the corridor. The light beam between the photocell and the reflector in the corridor must be interrupted. | p.82 |
| Reduced coverage, no alarm. | Strip not detected. | Retest marked object. | p.82 |
| Reduced coverage, no alarm. | System failure. | Place service call. Code number will be needed. | p.82 |
| Diagnostic code 7 in window. | Metallic object located too close to lattice. Examples: metal window or door frames, desks, counters, shelves, waste baskets, etc. | Move metal object or system until minimum distance is approximately 3 feet. | p.82 |
| Diagnostic code 8 in window. | Excessive electrical/electronic interference, generally caused by devices such as computers, CRTs, copiers, electronic fluorescent lights. | Decrease interference from device: Move device farther away from system. Turn device off. Use device with lower emissions. Shield device. | p.82 |
| No alarm, no patron count, no red power indicator on Electronic Enclosure. | No power at receptacle. | Reset facility circuit breaker. | p.83 |
| No alarm, no patron count, no red power indicator on Electronic Enclosure. | Power cord disconnected at receptacle. | Plug power cord in receptacle. | p.83 |
| No alarm, no patron count, no red power indicator on Electronic Enclosure. | System fuse open. | Replace fuse in power entry connector. | p.83 |
| No alarm, no patron count, no red power indicator on Electronic Enclosure. | Power turned off at Electronics Enclosure. | Turn key switch to ON. | p.83 |
| No alarm, no patron count, no red power indicator on Electronic Enclosure. | System failure. | Place service call. (1-800-328-0067) | p.83 |
| No alarm, no patron count, power indicator ON. | Processor requires reset. | Turn key switch OFF, wait 5 seconds, then turn switch ON. | p.83 |
| No alarm, no patron count, power indicator ON. | System failure. | Place service call. (1-800-328-0067) | p.83 |
| No alarm, patron counter works. | Strips in book desensitized or missing. | Resensitize books, or install Tattletape in book. | p.84 |
| No alarm, patron counter works. | System failure. | Place service call. (1-800-328-0067) | p.84 |
| No alarm, patron counter works. | Metal objects too close to panel. | Move all metal to minimum distance of 18 inches from the panels. | p.84 |
| Unwanted alarms. | Protected material from other library/retail store. | Identify material that caused alarm. | p.84 |
| Unwanted alarms. | Failure to desensitize marker properly. | Check desensitizing process and training. | p.84 |
| Unwanted alarms. | Miscellaneous metallic objects. | Infrequent unwanted alarms from some metal objects are possible. | p.84 |
| Unwanted alarms. | System failure. | Place service call. (1-800-328-0067) | p.84 |
| Reduced coverage, no alarm, patron counter works. | Metal objects too close to panel. | Move all metal objects to a minimum distance of 18 inches from panels. | p.84 |
| Reduced coverage, no alarm, patron counter works. | Electrical interference. | Remove possible sources of electrical interference such as computers, copiers, TVs, and electronic devices. | p.84 |
| Reduced coverage, no alarm, patron counter works. | Incomplete walk-through test. | Test the system by walking completely through just as a patron must. | p.84 |
| Reduced coverage, no alarm, patron counter works. | Books not properly resensitized. | Resensitize book, check sensitizing method and staff training. | p.84 |
| Reduced coverage, no alarm, patron counter works. | System failure. | Place service call. (1-800-328-0067) | p.84 |
| Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor. | Metal objects too close to panel. | Move all metal objects to a minimum of 3 feet from the panel. | p.84 |
| Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor. | Marked book or strips too close to panel. | Move marked books to a minimum of 3 feet from the panel. | p.84 |
| Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor. | Electrical interference. | Eliminate source of interference. | p.84 |
| Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor. | System failure. | Place service call. (1-800-328-0067) | p.84 |
| No alarm, no code in window. | No power at wall outlet. | Reset facility circuit breaker. | p.85 |
| No alarm, no code in window. | Panel unplugged. | Plug in and wait five minutes for full operation. | p.85 |
| No alarm, no code in window. | System circuit breaker tripped. | Reset the circuit breaker no more than three times. Call 3M Service if problem persists. | p.85 |
| No alarm, no code in window. | Power turned off at system panel. | Turn key switch to ON. | p.85 |
| No alarm, no code in window. | System failure. | Place service call. | p.85 |
| No alarm, code 3 in window. | Dirty fan filter. | Clean fan filter. | p.85 |
| No alarm, code 3 in window. | System failure. | Place service call. | p.85 |
| No alarm, code 5 in window. | Metal objects such as carts of trash cans next to system. | Remove interfering objects. Pull power cord at wall plug. Wait ten seconds. Reinsert plug and wait five minutes for full operation. | p.85 |
| No alarm, code 6 in win- dow. | Detection reduced due to presence of metal objects, computers, cash regis- ters, or electronic device next to sys- tem. | Check area directly next to panels. Move objects away. Retest system. | p.85 |
| No alarm, code 1, 2, 4, 7 or 8. | System failure. | Place service call. Code number will be needed. | p.86 |
| No alarm, patron count in window. | Marker deactivated. | Test system with another marked object with a sensitized strip. | p.86 |
| Infrequent unwanted alarms. | Failure to desensitize marker properly. | Check operator training procedures. | p.86 |
| Frequent (daily) unwanted alarms. | Failure to desensitize marker properly. | Follow correct check-out procedures outlined in 3M literature. Check operator training procedures. | p.86 |
| Frequent (daily) unwanted alarms. | Photocell or reflector lens dirty. | Clean with soft cloth and water. | p.86 |
| Frequent (daily) unwanted alarms. | System failure. | Place service call. Code number will be needed. | p.86 |
| Reduced coverage, no alarm. | Metallic object located too close to system. | Remove, maintain a minimum distance of 2 feet. | p.86 |
| Reduced coverage, no alarm. | Marker not detected. | Retest marked object. | p.86 |
| No alarm, code 9 in window. | System is in warm-up mode. | Wait approximately 1 minute. | p.86 |