EN
3M logo
Official user manual

3M 2301

91 pages·819 KB·Home Security System·PDF·ENDEFRITNLJA
3M 2301
Table of Contents 80 sections Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories · Operator’s Manual · 3M Library Security System Introduction · Section 1. Introduction · … ShowHide
Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessoriesp.1Operator’s Manualp.13M Library Security System Introductionp.5Section 1. Introductionp.53M Library Security System How the System Worksp.7Section 2. How the System Worksp.7966--02RDp.73M Library Security System System Configurationp.9Section 3. System Configurationp.93.1 Models 2301 and 2302p.92300--33CDp.92300--32CDp.93.2 Agency Approvalsp.103.3 Accessoriesp.113.4 Security Stripsp.113.5 Turning Your System Onp.123.6 How to Verify System Operationp.123.7 Emergency Shutdownp.133.8 Models 3501 and 3502p.143.9 FCC/Industry Canada/European/Australia EMC Compliancep.163500--17Lp.173.10 M3501/M3502 Detection Systemp.18! Cautionp.18! WARNINGp.183.11 Accessoriesp.193.12 Security Stripsp.193.13 Turning Your System Onp.203.14 How to Verify System Operationp.203.15 Emergency Shutdownp.213.16 Fuse Replacementp.213.17 Models 3801 and 3802p.223.18 Accessoriesp.233.19 Security Stripsp.233.20 Turning Your System Onp.243.21 How to Verify System Operationp.243.22 Emergency Shutdownp.253.24 DOC Radio Frequency Rules and Regulationsp.253.25 Agency Approvalsp.253.23 FCC Radio Frequency Rules and Regulationsp.253M Library Security System 3M Accessoriesp.273M Accessories 3M Library Security Systemp.28DSA-1p.29DVM-1p.29DAC-1p.29DCD-2p.29B1 (DS-B1-N)p.31B2 (DS-B2-N)p.31B1p.42B2p.42Warningp.47Model 764p.534.12 3M t Model 494 Locking Exit or Entrance Gatep.564.16 3M t SelfCheck t System Model 4210p.604.17 3M t Staff Workstation Model 995p.61B1 B2 DS-B1-N DS-B2-N DCD-2p.613M t Tattle-Tape t Security Strips 3M Library Security Systemp.635.1 Print Media Protection — 3M t Tattle-Tape t Security Strips: B1p.645.2 Print Media Protection — 3M t Tattle-Tape t Security Strips: B2p.665.3 Audio Cassette Protection — 3M t Tattle-Tape t Security Strips: DAC-1p.685.4 Compact Disc Protection — 3M t Tattle-Tape t Security Overlay: DCD-2p.705.5 Video Cassette Protection — 3M t Tattle-Tape t Security Strips: DVM-1p.723M Library Security System Training Your Staffp.75Section 6. Training Your Staffp.756.1 Operator’s Manualp.756.2 Training Videop.756.3 Hands-on Practicep.766.5 What To Do When The Alarm Soundsp.766.4 Review Of Your Library’s Security Policiesp.766.6 System Alarm Logp.786.7 Addressing Patron Concernsp.781. Test 2.Upon entering 3.Failure to desensitize 4. Undetermined 5. Real alarmp.793M Library Security Systems System Alarm Logp.796.8 Cleaning Instructionsp.806.9 Troubleshooting Guidep.816.10 Troubleshooting Guidep.836.11 Troubleshooting Guidep.856.12 Ordering Suppliesp.876.13 Obtaining Servicep.873M Library Security System Servicep.89Section 7. Servicep.89
Page 1 of the 3M 2301 user manual — Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories
Page 1 · click to enlarge
Page 1

Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories

Operator’s Manual

3M Library Systems 3M Center, Building 225-4N-14 P.O. Box 33225 St. Paul, MN 55133-3225

Printed in U.S.A. E 3M 1999 September 78-6970-6943-9 Rev B. Printed on recycled paper.

Page 2 of the 3M 2301 user manual — Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories
Page 2 · click to enlarge
Page 2

3M, Tattle-Tape, and SelfCheck are trademarks of 3M Company.

Page 3 of the 3M 2301 user manual — Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories
Page 3 · click to enlarge
Page 3
Page 3 of the 3M 2301 user manual — Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories
Page 4 of the 3M 2301 user manual — Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories
Page 4 · click to enlarge
Page 4
Page 4 of the 3M 2301 user manual — Library Security System Model 2301/2302, 3501/3502, 3801/3802, 3803/3804 and Accessories
Page 5 of the 3M 2301 user manual — 3M Library Security System Introduction
Page 5 · click to enlarge
Page 5

3M Library Security System Introduction

Section 1. Introduction

From the best-trained field service organization, to our technical service group and customer support staff, we are committed to providing you with the support you require to ensure your complete satisfaction.

The Global Leader in Library Materials Flow Management

People who remove materials from libraries without authorization are much like your average patron. Library materials are usually placed within book bags, briefcases or concealed under clothing. 3M detection systems have been designed to detect the unauthorized removal of materials concealed in this manner. While a 100% electronic net does not exist, the 3M system provides effective protection and significant reduction in the loss of library materials.

3M pioneered the concept of electronic protection of library materials more than 25 years ago. We are still leading the way.

Today, thousands of libraries around the world use the 3Mt Library Security System to protect their valuable collections. In fact, more libraries trust 3M than all other library security systems combined.

What this means to you

With a little attention and care, your 3M system should provide you with many years of service and help to protect your library against thousands of dollars in losses.

This manual explains how your 3M Library Security System operates. By becoming familiar with the information this manual contains, you and your staff will derive the maximum benefits from your system. But do not hesitate to contact us if you have questions.

Call our toll-free 800 number any time of day or night for service, to order supplies, to leave messages for your sales representative, or to contact the 3M credit department:

1-800-328-0067

Page 6 of the 3M 2301 user manual — 3M Library Security System Introduction
Page 6 · click to enlarge
Page 6

3M Library Security System Introduction

Blank Page

Page 7 of the 3M 2301 user manual — 966--02RD
Page 7 · click to enlarge
Page 7

3M Library Security System How the System Works

Section 2. How the System Works

Checking out materials is accomplished using desensitizers to “turn off” the strips while resensitizers are used to turn the strips back on when materials are returned to the library. This allows for full circulation of all library materials.

Your 3Mt Library System consists of several components, including 3Mt Tattle-Tapet Security Strips, circulation accessories, and the detection system(s).

The 3M detection system is designed to detect sensitized 3M Tattle-Tape security strips and then sound an alarm, thus preventing unauthorized removal of library materials.

The key to the effectiveness of the system is protecting your materials with 3M Tattle-Tape security strips. Only when materials are protected can the 3M Detection system detect someone trying to leave the library without properly checking out items.

It is this simple:

Mark materials as described in this manual.

Circulate materials using desensitizers and resensitizers described in the Accessories section.

The primary zone of detection between the lattices extends from the floor to 72 inches [1,82 m] above the floor. The electronic coverage in this area is not 100% and it will vary with the options you have and the type of 3M security markers you use. The rate of detection in this area is effective to deter the loss of protected materials.

Listen for the 3M detection system alarm to sound when unauthorized removal of materials occurs. Of course, it is also important to watch for suspicious actions such as holding materials above the head and passing items around the lattices when passing through the detection system.

3M offers several models of detection systems to meet your library’s needs. See the next section for the details on the various models.

3M 2301 — 3M Library Security System How the System Works diagram (page 7)
Fig. 1 · 3M Library Security System How the System Works

966--02RD

Page 8 of the 3M 2301 user manual — 3M Library Security System How the System Works
Page 8 · click to enlarge
Page 8

3M Library Security System How the System Works

Blank Page

Page 9 of the 3M 2301 user manual — 2300--32CD
Page 9 · click to enlarge
Page 9

3M Library Security System System Configuration

Section 3. System Configuration

3.1 Models 2301 and 2302

The detection lattices are shown below:

Patron Counter/Alarm Counter/ Diagnostic Display

2300--33CD

Patron Counter/Alarm Counter/ Diagnostic Display

2300--32CD

Show 16 more labels / short text on this page
Lattice B · Lattice A · Alarm Indicator Light · Photocell Reflector · Photocell · Circuit Breaker · Model 2301BP · Lattice C · Alarm Indicator Light · Lattice B · Lattice A · Alarm Indicator Light · Photocell Reflector · Photocell · Circuit Breaker · Model 2302BP
Page 10 of the 3M 2301 user manual — 3.2 Agency Approvals
Page 10 · click to enlarge
Page 10

3M Library Security System System Configuration

FCC Radio Frequency Rules and Regulations

Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de Classe A prescrites dans le reglement sur le brouillage radioelectrique edicte par le Ministere des Communications du Canada.

This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

3.2 Agency Approvals

The safety related fire, shock, and injury aspects of the Model 2300 series have been investigated to UL 1950, CSA 22.2 No. 950, and EN 60950 standards by Underwriters Laboratories Inc. Burglary and theft protection features have not been evaluated.

DOC Radio Frequency Rules and Regulations

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the radio inteference regulations of the Canadian Department of Communications.

Page 11 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 11 · click to enlarge
Page 11

3M Library Security System System Configuration

3.3 Accessories

3.4 Security Strips

A variety of accessories is available for use with your 3Mt Detection System Model 2301/2302. However, it is unlikely that any one customer will use every accessory.

3M has a wide range of security strips to protect your merchandise. Any of the security strips listed below may be used effectively with the detection systems Models 2301/2302.

3M Tattle-Tape Security Strips

The 3Mt Desensitizers are designed to desensitize 3Mt Tattle-Tapet Security Strips. Security strips on protected items must be properly desensitized so the items can be carried through the system without causing an alarm.

B1 - for print materials B2 - for print materials DAC-1 - for audio cassettes DCD-2 - for audio CDs and CD-ROMs DSA-1 - for audio cassettes DVM-1 - for video cassettes

3M desensitizers used with 3M Tattle-Tape security strips:

Model 763 On-counter, magnetic media Model 766 Handheld, magnetic media Model 930 On-counter Model 2001 On-counter, magnetic media (strips only) Model 2001M On-counter, magnetic media Model 2004 In-counter Model 955 Bookcheck Model 966 Bookcheck

Security strips on protected items must be properly resensitized to ensure items carried through the system will cause an alarm.

3Mt Resensitizers used with 3M Tattle-Tape security strips:

Model 2011 On-counter, magnetic media Model 955 Bookcheck Model 966 Bookcheck Model 951 Handheld Model 764 On-counter, for printed material and compact discs

Locking exit gates and an entrance gate can be installed on the system.

3Mt SelfCheckt System

The 3Mt SelfCheckt System is a library system used by patrons to check out their own library materials. It completes library loan transactions by desensitizing 3M Tattle-Tape security strips and recording the transaction in the library circulation system.

Desensitizers · Resensitizers · Gates

Page 12 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 12 · click to enlarge
Page 12

3M Library Security System System Configuration

3.5 Turning Your System On

3.6 How to Verify System Operation

Your 3Mt Detection System Model 2301/2302 has been designed to be left on continuously.

Your 3M detection system Model 2301/2302 should be inspected daily for proper operation.

To turn the system on:

System operation may be verified with the built-in Diagnostic Display which is located on lattice A. During normal operation, the current patron count and alarm count will be displayed. A leading “P” indicates a patron count (for example, P123456). A leading “A” indicates an alarm count (for example, A1234).

2301/2302 Baseplate Mounting - Connect the power cord to a power outlet.

2301/2302 Direct Mount - Connect the power cord to a power outlet, and turn the key switch to On.

If a system problem should occur, a code number will appear in the Diagnostic Display. Refer to the Troubleshooting Guide, Section 6-9, if a code number is present.

Allow two minutes for the system to warm up.

3M 2301 — 3M Library Security System System Configuration diagram (page 12)
Fig. 2 · 3M Library Security System System Configuration

An alarm condition is indicated by an audible signal. The specific corridor in which an alarm condition exists is indicated by the light built into the top of lattice A or C.

There is no need for repetitive walk-through testing.

Page 13 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 13 · click to enlarge
Page 13

3M Library Security System System Configuration

3.7 Emergency Shutdown

2. Disconnect the power cord from the power outlet.

If an emergency occurs, remove power from the system by one of the following methods:

3. If step 2 is not possible, set the facility circuit breaker for the system to OFF.
1. Turn On/Off Key Switch to OFF.
Page 14 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 14 · click to enlarge
Page 14

3M Library Security System System Configuration

3.8 Models 3501 and 3502

The Detection Panels are shown below:

Fuse & voltage selector

Power cord Panel A

Show 8 more labels / short text on this page
Key switch · Electronic enclosure · Alarm light · Power receptacle · Photocell/reflector · Panel B · Alarm Counter · Model 3501
Page 15 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 15 · click to enlarge
Page 15

3M Library Security System System Configuration

Fuse & voltage selector

Show 11 more labels / short text on this page
Key switch · Electronic enclosure · Alarm light · Power receptacle · Power cord · Panel A · Photocell/reflector · Panel B · Panel C · Counter Alarm · Model 3502
Page 16 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 16 · click to enlarge
Page 16

3M Library Security System System Configuration

3.9 FCC/Industry Canada/European/Australia EMC Compliance

Industry Canada Radio Frequency Rules and Regulations

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

FCC Radio Frequency Rules and Regulations

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can emit radiated radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.

This unit complies with the EMC requirements for Australia.

3M 2301 — 3M Library Security System System Configuration diagram (page 16)
Fig. 3 · 3M Library Security System System Configuration

Australia

Page 17 of the 3M 2301 user manual — 3500--17L
Page 17 · click to enlarge
Page 17

3M Library Security System System Configuration

3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 4 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 5 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 6 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 7 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 8 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 9 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 10 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 11 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 12 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 13 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 17)
Fig. 14 · 3M Library Security System System Configuration

3500--17L

Page 18 of the 3M 2301 user manual — ! Caution
Page 18 · click to enlarge
Page 18

3M Library Security System System Configuration

3.10 M3501/M3502 Detection System

! Caution

Personal Injury Hazard.

The 3Mt Detection System Model 3501/3502 is designed to detect the unauthorized removal of media from the library. It is designed to be positioned inside the library at the library exit. All exiting traffic should be directed through the Model 3501/3502 to maximize effectiveness. This system is designed for continuous operation. For maximum protection of the library media, use Tattle-Tapet Security Strips and 3Mt Accessories.

Attempting to change fuses without unplugging the Detection System may cause personal injury. Inserting the fuse holder in the incorrect direction could blow the fuse.

To avoid any possibility of injury, disconnect the power before attempting to change the fuse. To avoid blowing the fuse, insert the fuse holder in the correct direction. For continued protection against risk of fire, replace only with the same type and rating of fuse.

! Caution

! WARNING

Possible personal injury or equipment damage. Incorrect configuration and installation of the 120/240 voltage selector may cause personal injury or equipment damage.

Personal Injury Hazard. Risk of electrical shock present. Not operator serviceable. Refer all servicing to 3M factory trained service personnel. Do not open of enter panels or electronic enclosure.

Install the fuse holder/voltage selector in the correct orientation. See additional information in this manual on voltage configuration and fuses.

High Voltage · Internal Use · High Voltage

Page 19 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 19 · click to enlarge
Page 19

3M Library Security System System Configuration

3.11 Accessories

3.12 Security Strips

A variety of accessories is available for use with your 3Mt Detection System Model 3501/3502. However, it is unlikely that any one customer will use every accessory.

3M has a wide range of security strips to protect your merchandise. Any of the security strips listed below may be used effectively with the detection systems Models 3501/3502.

3M Tattle-Tape security strips

The 3Mt Desensitizers are designed to desensitize 3Mt Tattle-Tapet Security Strips. Security strips on protected items must be properly desensitized so the items can be carried through the system without causing an alarm.

B1 - for print materials B2 - for print materials DAC-1 - for audio cassettes DCD-2 - for audio CDs and CD-ROMs DSA-1 - for audio cassettes DVM-1 - for video cassettes

3M Desensitizers used with 3M Tattle-Tape security strips:

Model 763 On-counter, magnetic media Model 766 Handheld, magnetic media Model 930 On-counter Model 2001 On-counter, magnetic media Model 2001M On-counter, magnetic media Model 2004 In-counter Model 955 Bookcheck Model 966 Bookcheck

Security strips on protected items must be properly resensitized to ensure items carried through the system will cause an alarm.

3Mt Resensitizers used with 3M Tattle-Tape security strips:

Model 2011 On-counter, magnetic media Model 955 Bookcheck Model 966 Bookcheck Model 951 Handheld Model 764 On-counter, for printed material and compact discs

3Mt SelfCheckt System

The 3Mt SelfCheckt System is a library system used by patrons to check-out their own library materials. It completes library loan transactions by desensitizing 3M Tattle-Tape security strips and recording the transaction in the library circulation system.

Desensitizers · Resensitizers

Page 20 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 20 · click to enlarge
Page 20

3M Library Security System System Configuration

3.13 Turning Your System On

3.14 How to Verify System Operation

The 3Mt Detection System Model 3501/3502 is designed to be left on continuously.

Your 3Mt Detection System Model 3501/3502 should be inspected daily for proper operation.

To turn on, connect the Electronics Enclosure power cord to a power outlet. Turn the On/Off key switch to ON. The Power On indicator light should be on.

Proper system operation is indicated when the red power indicator light is illuminated. System operation may be verified by passing through the system with a marked book, which should result in an audible alarm and a light on at the top of the panels. Each pass through the system should also increment the counter by one. The alarm/inhibit light on the Electronics Enclosure should also be illuminated (green) at the time of alarm. If the system does not respond, see the Troubleshooting Guide in Section 6.

Allow 15 seconds for the system to start up.

There is no need for repetitive walk-through testing.

Page 21 of the 3M 2301 user manual — 3.16 Fuse Replacement
Page 21 · click to enlarge
Page 21

3M Library Security System System Configuration

3.15 Emergency Shutdown

3M 2301 — 3M Library Security System System Configuration diagram (page 21)
Fig. 15 · 3M Library Security System System Configuration

If an emergency occurs, remove power from the Model 3500 system by one of the following methods:

1. Turn On/Off Key Switch to OFF.
2. Disconnect the power cord from the power outlet.
3. If step 2 is not possible, set the facility circuit breaker for the system to OFF.
3M 2301 — 3M Library Security System System Configuration diagram (page 21)
Fig. 16 · 3M Library Security System System Configuration

3.16 Fuse Replacement

The fuses are located on the bottom of the Electronic Enclosure in the power entry connector.

3M 2301 — 3.16 Fuse Replacement diagram (page 21)
Fig. 17 · 3.16 Fuse Replacement
3M 2301 — 3.16 Fuse Replacement diagram (page 21)
Fig. 18 · 3.16 Fuse Replacement
3M 2301 — 3.16 Fuse Replacement diagram (page 21)
Fig. 19 · 3.16 Fuse Replacement
1. Turn the key switch to OFF and disconnect the power cord from the power source.
2. Using a small flat blade screwdriver, remove the fuse block from the power entry connector.
3. Do not remove the voltage selection block as this has been set by the installer at the correct voltage.
5. Reinstall the fuse block, connect the power cord to the power source, and turn the key switch to ON.
4. Replace the failed fuses with the correct fuse for your operating voltage:

a. Up to 125VAC, use a 4A fuse.

b. Voltages over 125VAC to 250VAC, use a 3.15A fuse.

Page 22 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 22 · click to enlarge
Page 22

3M Library Security System System Configuration

3.17 Models 3801 and 3802

The Detection Panels are shown below:

3M 2301 — 3M Library Security System System Configuration diagram (page 22)
Fig. 20 · 3M Library Security System System Configuration
3M 2301 — 3M Library Security System System Configuration diagram (page 22)
Fig. 21 · 3M Library Security System System Configuration

The 3800 System is also available in a 3-corridor 3803 model and a 4-corridor 3804 model.

Page 23 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 23 · click to enlarge
Page 23

3M Library Security System System Configuration

3.18 Accessories

3.19 Security Strips

A variety of accessories is available for use with your 3Mt Detection System Model 3801/3802. However, it is unlikely that any one customer will use every accessory.

3M has a wide range of security strips to protect your merchandise. Any of the security strips listed below may be used effectively with the Detection Systems Models 3801/3802.

3M Tattle-Tape Security Strips

The 3Mt Desensitizers are designed to desensitize 3Mt Tattle-Tapet Security Strips. Security strips on protected items must be properly desensitized so the items can be carried through the system without causing an alarm.

B1 - for print materials B2 - for print materials DAC-1 - for audio cassettes DCD-2 - for audio CDs and CD-ROMs DSA-1 - for audio cassettes DVM-1 - for video cassettes

3M desensitizers used with 3M Tattle-Tape security strips:

Model 763 On-counter, magnetic media Model 766 Handheld, magnetic media Model 930 On-counter Model 2001 On-counter, magnetic media Model 2001M On-counter, magnetic media Model 2004 In-counter Model 955 Bookcheck Model 966 Bookcheck

Security strips on protected items must be properly resensitized to ensure items carried through the system will cause an alarm.

3Mt Resensitizers used with 3M Tattle-Tape security strips:

Model 2011 On-counter, magnetic media Model 955 Bookcheck Model 966 Bookcheck Model 951 Handheld Model 764 On-counter, for printed material and compact discs

Locking exit gates and an entrance gate can be installed on the system.

3Mt SelfCheckt System

The 3Mt SelfCheckt System is a library system used by patrons to check-out their own library materials. It completes library loan transactions by desensitizing 3M Tattle-Tape security strips and recording the transaction in the library circulation system.

Desensitizers · Resensitizers · Gates

Page 24 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 24 · click to enlarge
Page 24

3M Library Security System System Configuration

3.20 Turning Your System On

3.21 How to Verify System Operation

The power On/Off switch is a key switch located on one end of the corridor at the base of the electronics chassis. The 3Mt Detection System Model 3801/3802 is designed to be left on continuously.

Your 3M detection system Model 3801/3802 should be inspected daily for proper operation.

System operation may be verified with the built-in Diagnostic Display located on one security panel. During normal operation, the current patron count or alarm count will be alterately displayed at 15 second intervals. A leading “P” indicates a patron count (for example, P123456). A leading “A” indicates an alarm count (for example, A123456).

To turn the system on, insert the key and turn the key switch to the ON position. The green light above the key switch will light, indicating the system is on. They key should always be removed from the system to prevent tampering.

Allow two minutes for the system to warm up. A “DIAG9” will appear in the “Patron Counter/Diagnostic Display” during warm-up. Thereafter, the patron count or alarm count will be displayed.

If a system problem should occur, a code number will appear in the Diagnostic Display. Refer to the Troubleshooting Guide, Section 6, if a code number is present.

An alarm condition is indicated by an audible signal. The specific corridor in which an alarm condition exists is indicated by the light built into the top of panel A or C.

There is no need for repetitive walk-through testing.

Page 25 of the 3M 2301 user manual — 3.23 FCC Radio Frequency Rules and Regulations
Page 25 · click to enlarge
Page 25

3M Library Security System System Configuration

3.22 Emergency Shutdown

3.24 DOC Radio Frequency Rules and Regulations

If an emergency occurs, remove power from the system by one of the following methods:

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the radio inteference regulations of the Canadian Department of Communications.

6. Turn On/Off Key Switch to Off.
7. Disconnect the power cord from the power outlet.
8. If steps 1 and 2 are not possible, set the facility circuit breaker for the system to off.

3.25 Agency Approvals

The safety related fire, shock, and injury aspects of the Model 2300, 3500, and 3800 series have been investigated to UL 1950, CSA 22.2 No. 950, and EN 60950 standards by Underwriters Laboratories Inc. Models also comply with European CE requirements. Burglary and theft protection features have not been evaluated.

3.23 FCC Radio Frequency Rules and Regulations

This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Page 26 of the 3M 2301 user manual — 3M Library Security System System Configuration
Page 26 · click to enlarge
Page 26

3M Library Security System System Configuration

Blank Page

Page 27 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 27 · click to enlarge
Page 27

3M Library Security System 3M Accessories

Section 4. 3M Accessories for Use with the 3Mt Library Security System

Accessories Used with the 3M Library Security System

Desensitizers Page M766 Handheld magnetic media 4-2 M930 On-counter 4-4 M2001 On-counter, magnetic media 4-6 . . M2001M On-counter, magnetic media 4-8 . . M2004 In-counter, general use 4-10 M955 Bookcheck 4-17 M966 Bookcheck 4-21 M763 On-counter, magnetic media 4-25 . .

3M has a variety of security strips and accessories, desensitizers and resensitizers for use with the 3Mt Library Security System. Security strips and their uses are described in Section 5.

This section contains information for proper use and operation of the accessories used with the 3M detection systems. You may have one or more of these accessories depending on your operation, volume, and selection of materials to be protected. For specific information on using your accessory devices, locate the page(s) describing the device.

Resensitizers M2011 On-counter, magnetic media 4-12 . . M951 Handheld 4-14 M955 Bookcheck 4-17 M966 Bookcheck 4-21 M764 On-counter, print and CD media4-27

Gate M494 Locking Exit or Entrance Gate 4-30

3Mt SelfCheckt System M5210 SelfCheck System 4-31 M5220 SelfCheck System 4-32 M6210 SelfCheck System 4-33 M4210 SelfCheck System 4-34

3Mt Staff Workstation M995 Staff Workstation 4-35

Description/Characteristics

Page 28 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 28 · click to enlarge
Page 28

3M Accessories 3M Library Security System

4.1 3Mt Handheld Desensitizer Model 766 (For Use With Recorded Magnetic Media)

Draw the 3M Model 766 across the marked article with the desensitizing element in full contact with the security strip.

The 3M Desensitizer Model 766 is designed to desensitize surface-applied 3Mt Tattle-Tapet Security Strips. This includes security strips which have been applied to recorded magnetic media such as audio cassettes, video cassettes, or boxed computer software.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 28)
Fig. 22 · 3M Accessories 3M Library Security System

Security strips on protected items must be properly desensitized so the items can be carried through the library system without causing an alarm.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 28)
Fig. 23 · 3M Accessories 3M Library Security System

Only one pass is necessary to fully desensitize a security strip.

Passing the 3M Model 766 across the security strip first in one direction and then in the other (scrubbing motion) may partially resensitize the security strip and cause unwanted alarms.

The 3M Model 766 is a non-electric, handheld device which requires no installation. However, the security cable should be attached to prevent unauthorized removal.

Show 4 more labels / short text on this page
Operating Instructions · Description/Characteristics · Model 766 · Installation
Page 29 of the 3M 2301 user manual — DCD-2
Page 29 · click to enlarge
Page 29

3M Library Security System 3M Accessories

Security Strips Used with the 3M Model 766 Desensitizer

Typical Items Used with the 3M Model 766 Desensitizer

3Mt Tattle-Tapet Security Strips (surface-applied)

Make sure that the 3M Model 766 desensitizing element contacts the security strip.

DSA-1

DVM-1

DAC-1

All general items (with surface-applied security strips)

DCD-2

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

To avoid damage to credit cards or computer disks, do not permit the 3M Model 766 to make direct contact with credit cards or computer disks.

The 3M Model 766 should be used and stored away from areas which are readily accessible to customers.

Security Strip Storage Conditions

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock, first in, first out.

Show 6 more labels / short text on this page
Audio cassettes · Video cassettes · Packaged computer software · Compact discs · Security Strip Application · Exceptions
Page 30 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 30 · click to enlarge
Page 30

3M Accessories 3M Library Security System

4.2 3Mt On-Counter Desensitizer Model 930 (Not For Use With Recorded Magnetic Media)

To desensitize security strips in books or magazines:

Draw the spine of the book or magazine across the top of the 3M Model 930. Keep the spine of the marked item in full contact with the desensitizer.

The 3Mt On-counter Desensitizer Model 930 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, and other general items.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 30)
Fig. 24 · 3M Accessories 3M Library Security System

The 3M Model 930 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer disks as they may be damaged.

Security strips on protected items must be properly desensitized so the items can be carried through the library system without causing an alarm.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 30)
Fig. 25 · 3M Accessories 3M Library Security System

To desensitize security strips on general items and unrecorded magnetic media:

Draw the marked item across the top of the 3M Model 930. Keep the security strip in full contact with the desensitizer.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 30)
Fig. 26 · 3M Accessories 3M Library Security System

The 3M Model 930 is a moveable, non-electric, on-counter device which requires no installation. However, it should be located away from areas which are readily accessible to customers.

A yellow warning label is supplied by 3M and should be secured on or near the 3M Model 930 to advise customers of potential damage to recorded magnetic media.

Only one pass is necessary to fully desensitize a security strip.

Passing the marked item across the 3M Model 930 first in one direction and then in the other (scrubbing motion), may partially resensitize the security strip and cause unwanted alarms.

Show 4 more labels / short text on this page
Operating Instructions · Description/Characteristics · Model 930 · Installation
Page 31 of the 3M 2301 user manual — B1 (DS-B1-N)
Page 31 · click to enlarge
Page 31

3M Library Security System 3M Accessories

Security Strips Used with 3Mt Desensitizer Model 930

Typical Items Used with 3M Model 930 Desensitizer

3Mt Tattle-Tapet Security Strips

All general items — excluding recorded magnetic media.

B1 (DS-B1-N)

B2 (DS-B2-N)

DCD-2

Keep credit cards, recorded magnetic media (audio tapes, video tapes or computer disks) and stem-wind and self-wind wrist watches at least six inches [150 mm] away from the 3M Model 930 surface to prevent magnetic damage. A yellow warning label is supplied by 3M and should be secured on or near the 3M Model 930 to advise customers of potential damage to recorded magnetic media. Keep a minimum of 12 inches from computers and computer displays (CRTs).

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

The 3M Model 930 should be installed away from areas which are readily accessible to customers.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Security Strip Storage Conditions

Store security strips at 50 -- 90F [10 -- 32 C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Store security strips at least two feet [0,6 m] away from the 3M Model 930.

Show 4 more labels / short text on this page
Books · Magazines · Exceptions · Security Strip Application
Page 32 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 32 · click to enlarge
Page 32

3M Accessories 3M Library Security System

4.3 3Mt On-Counter Desensitizer Model 2001 (For Use With Recorded Magnetic Media)

To desensitize security strips:

S Draw the marked item across the black plate on the Model 2001.

The 3Mt On-counter Desensitizer Model 2001 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to records, audio cassettes, and prepackaged computer software.

S Make sure the security strip is in full contact with the black plate on the Model 2001.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 32)
Fig. 27 · 3M Accessories 3M Library Security System

This device is not intended to desensitize security strips which have been applied directly to computer software, as the disks may be damaged.

Security strips on protected items must be properly desensitized so the items can be carried through the library security system without causing an alarm.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 32)
Fig. 28 · 3M Accessories 3M Library Security System

Only one pass is necessary to fully desensitize a security strip.

Passing the marked item across the 3M Model 2001 first in one direction and then in the other (scrubbing motion) may partially resensitize the strip and cause unwanted alarms.

The 3M Model 2001 is a moveable, non-electric, on-counter device which requires no installation. However, the 3M Model 2001 should be used away from areas which are readily accessible to customers.

To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001.

Show 4 more labels / short text on this page
Operating Instructions · Description/Characteristics · Model 2001 · Installation
Page 33 of the 3M 2301 user manual — DAC-1
Page 33 · click to enlarge
Page 33

3M Library Security System 3M Accessories

Security Strips Used with the 3Mt Desensitizer Model 2001

Typical Items Used with the 3M Model 2001 Desensitizer

3Mt Tattle-Tapet Security Strips

DAC-1

DVM-1

DSA-1

To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001. Computer software disks should be enclosed in a box or case to keep the disks at least 1/4 inch [6 mm] from the Model 2001 surface.

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

The 3M Model 2001 should be used and stored away from areas which are readily accessible to customers.

Security Strip Storage Conditions

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Show 6 more labels / short text on this page
Records · Audio cassettes · Video cassettes · Boxed computer software · Exceptions · Security Strip Application
Page 34 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 34 · click to enlarge
Page 34

3M Accessories 3M Library Security System

4.4 3Mt On-Counter Desensitizer Model 2001M (For Use With Recorded Magnetic Media)

To desensitize security strips:

S Draw the marked item across the black plate on the Model 2001M.

The 3M On-counter Desensitizer Model 2001M is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to records, boxed audio cassettes, video cassettes, compact disks and boxed computer software.

S Make sure the security strip is in full contact with the black plate on the Model 2001M.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 34)
Fig. 29 · 3M Accessories 3M Library Security System

This device is not intended to desensitize security strips which have been applied directly to unboxed audio cassettes or to computer software, as they may be damaged. However, security strips may be applied to boxed computer software.

Security strips on protected items must be properly desensitized so the items can be carried through the library security system without causing an alarm.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 34)
Fig. 30 · 3M Accessories 3M Library Security System

Only one pass is necessary to fully desensitize a security strip.

Passing the marked item across the 3M Model 2001M first in one direction and then in the other (scrubbing motion) may partially resensitize the security strip and cause unwanted alarms.

The 3M Model 2001M is a non-electric, moveable on-counter device which requires no installation. However, the security cable should be attached to prevent unauthorized removal.

To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001M.

Show 4 more labels / short text on this page
Operating Instructions · Description/Characteristics · Model 2001M · Installation
Page 35 of the 3M 2301 user manual — DAC-1
Page 35 · click to enlarge
Page 35

3M Library Security System 3M Accessories

Security Strips Used with the 3Mt Desensitizer Model 2001M

Typical Items Used with the 3M Model 2001M Desensitizer

3Mt Tattle-Tapet Security Strips

DAC-1

DSA-1

DVM-1

To avoid damage to credit cards or computer software, do not permit credit cards or computer software to make direct contact with the 3M Model 2001M. Computer software disks should be enclosed in a box or case to keep the disks at least 1/4 inch [6 mm] from the Model 2001 surface.

Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

The 3M Model 2001M should be installed away from areas which are readily accessible to customers.

Security Strip Storage Conditions

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Show 6 more labels / short text on this page
Records · Boxed audio cassettes · Video cassettes · Boxed computer software · Exceptions · Security Strip Application
Page 36 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 36 · click to enlarge
Page 36

3M Accessories 3M Library Security System

4.5 3Mt In-Counter Desensitizer Model 2004 (Not For Use With Recorded Magnetic Media)

Pass the marked article across the face of the Model 2004 with the security strip in full contact with the surface of the desensitizer.

The 3Mt Desensitizer Model 2004 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips in or on books, magazines, and other general items.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 36)
Fig. 31 · 3M Accessories 3M Library Security System

The 3M Model 2004 is not intended to be used with recorded magnetic media such as audio or video cassettes or computer software.

Security strips on protected items must be properly desensitized so the items can be carried through the library system without causing an alarm.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 36)
Fig. 32 · 3M Accessories 3M Library Security System

The 3M Model 2004 is a non-electric device which is designed to be permanently installed in the checkout counter.

A yellow warning label is supplied by 3M and should be secured on or near the Model 2004 to advise customers of potential damage to recorded magnetic media.

Only one pass is necessary to fully desensitize a security strip.

Passing the marked item across the 3M Model 2004 first in one direction and then in the other (scrubbing motion) may partially resensitize the security strip and cause unwanted alarms.

Show 4 more labels / short text on this page
Operating Instructions · Description/Characteristics · Model 2004 · Installation
Page 37 of the 3M 2301 user manual — B1 (DS-B1-N)
Page 37 · click to enlarge
Page 37

3M Library Security System 3M Accessories

Security Strips Used with the 3Mt Desensitizer Model 2004

Typical Items Used with the 3M Desensitizer Model 2004

3Mt Tattle-Tapet Security Strips

All general items — excluding recorded magnetic media.

B1 (DS-B1-N)

B2 (DS-B2-N)

DCD-2

Keep credit cards, recorded magnetic media (audio tapes, video tapes or computer disks) and stem-wind and self-wind wrist watches at least six inches [150 mm] away from the 3M Model 2004 surface to prevent magnetic dam- age. A yellow warning label is supplied by 3M and should be secured on or near the 3M Model 2004 to advise customers of potential damage to recorded magnetic media. Keep a minimum of 12 inches ffom computers and computer displays (CRTs).

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Security Strip Storage Conditions

Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Store security strips at least two feet [0,6 m] away from the Model 2004.

Show 4 more labels / short text on this page
Books · Magazines · Exceptions · Security Strip Application
Page 38 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 38 · click to enlarge
Page 38

3M Accessories 3M Library Security System

4.6 3Mt On-Counter Resensitizer Model 2011 (For Use With Recorded Magnetic Media)

To resensitize security strips, pass the marked article across the surface of the 3M Model 2011. Make sure the security strips are in full contact with the 3M Model 2011.

The 3Mt On-counter Resensitizer Model 2011 is designed to resensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to audio cassettes or video cassettes.

Strips passed across the 3M Model 2011 in the direction opposite the arrows will not be resensitized.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 38)
Fig. 33 · 3M Accessories 3M Library Security System

This device is not intended to resensitize security strips which have been applied directly to computer disks, as the disks may be damaged.

Security strips must be resensitized when the marked items are returned. Improperly resensitized items will not alarm when passed through the library system.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 38)
Fig. 34 · 3M Accessories 3M Library Security System

The 3M Model 2011 is a moveable, non-electric, on-counter device which requires no installation.

The 3M Model 2011 should be located away from areas which are readily accessible to customers.

Only one pass is necessary to fully resensitize each security strip.

To avoid damage to credit cards or computer software: Do not attempt to resensitize security strips which have been applied directly to computer software. Do not permit credit cards or computer software disks to make direct contact with the 3M Model 2001.

Show 4 more labels / short text on this page
Operating Instructions · Description/Characteristics · Model 2011 · Installation
Page 39 of the 3M 2301 user manual — DSA-1
Page 39 · click to enlarge
Page 39

3M Library Security System 3M Accessories

Security Strips Used with the 3Mt Resensitizer Model 2011

Typical Items Used with the 3M Resensitizer Model 2011

3Mt Tattle-Tapet Security Strips

DAC-1

DVM-1

To avoid damage to credit cards or computer software: Do not attempt to resensitize security strips which have been applied directly to computer software. Do not permit credit cards or computer software disks to make direct contact with the 3M Model 2001.

DSA-1

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips and labels.

Security Strip Storage Conditions

Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Show 4 more labels / short text on this page
Video cassettes · Audio cassettes · Exceptions · Security Strip Application
Page 40 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 40 · click to enlarge
Page 40

3M Accessories 3M Library Security System

4.7 3Mt Handheld Resensitizer Model 951 (Not For Use With Recorded Magnetic Media)

The 3M Model 951 is a portable device which requires no installation other than plugging it into the proper power source.

The 3Mt Resensitizer Model 951 is designed to resensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, periodicals, and compact discs.

The 3M Model 951 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer software.

The 3M Tattle-Tape security strips should be resensitized when the protected items are returned. Improperly resensitized items will not alarm when passed through the detection system.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 40)
Fig. 35 · 3M Accessories 3M Library Security System

Installation · Description/Characteristics · Model 951

Page 41 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 41 · click to enlarge
Page 41

3M Library Security System 3M Accessories

The center of the Model 951 must pass directly over the security strip and no farther than1/4 inch [6 mm] above the strip.

Turn the Model 951 on at least six inches [150 mm] from the 3Mt Tattle-Tapet Security Strip.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 41)
Fig. 36 · 3M Library Security System 3M Accessories
3M 2301 — 3M Library Security System 3M Accessories diagram (page 41)
Fig. 37 · 3M Library Security System 3M Accessories

Pass the resensitizer slowly along the object where the security strip is located. Continue beyond the security strip before turning the resensitizer off.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 41)
Fig. 38 · 3M Library Security System 3M Accessories

The recommended duty cycle for the Model 951 is one minute on and five minutes off.

3 inches 76 mm

1 second 1 segundo

3M 2301 — 3M Library Security System 3M Accessories diagram (page 41)
Fig. 39 · 3M Library Security System 3M Accessories

Operating Instructions · Resensitizing Security Strips

Page 42 of the 3M 2301 user manual — DCD-2
Page 42 · click to enlarge
Page 42

3M Accessories 3M Library Security System

Security Strips Used with the 3Mt Resensitizer Model 951

Problem: The Model 951 will not resensitize any strip.

3Mt Tattle-Tapet Security Strips

D The Model 951 is not connected to a working power outlet.

B1

B2

Solution: Plug the Model 951 into a working power outlet.

DCD-2

D The internal thermal sensor is open.

Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

The resensitizer may have been used or turned “ON” for too long a time, allowing it to over heat. The recommended duty cycle is one minute on and five minutes off.

Typical Items Used with the 3M Resensitizer Model 951

Solution: Allow the Model 951 to cool.

Problem: Poor or inconsistent resensitizing.

D Passing the Model 951 along the length of a security strip too fast.

Solution: Slow the speed for resensitizing to approximately three inches [75 mm] per second.

D The center of the Model 951 resensitizing element is not directly over the security strip.

Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least six inches [150 mm] away from the 3M Model 951 surface to prevent magnetic damage.

D The Model 951 is more than 1/4 inch [6 mm] away from the security strip.

Solution: Verify that the Model 951 is being used directly over the security strip and is not more than 1/4 inch [6 mm] away from the security strip.

Security Strip Storage Conditions

Store security strips at 50 -- 90 F (10 -- 32 C) and at 20 -- 70% relative humidity.

Problem: Cracked or damaged housing.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Solution: Discontinue use immediately. The Model 951 is not repairable. Replace the unit.

Show 7 more labels / short text on this page
Troubleshooting · Security Strip Application · Books · Magazines · Periodicals · Compact discs · Exceptions
Page 43 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 43 · click to enlarge
Page 43

3M Library Security System 3M Accessories

4.8 3Mt Bookcheck Model 955 (Not For Use With Recorded Magnetic Media)

The Model 955 may be placed either on or under the circulation counter.

The 3Mt Bookcheck Model 955 is designed to desensitize and resensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, periodicals, and compact discs.

The Model 955 is capable of operating from a nominal voltage of 115 volts or 230 volts. The voltage selection switch on the back of the Model 955 must be moved to the proper position before it may be used for the first time.

The Model 955 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer software.

Set the voltage selection switch to the 115 position when operating from 100 to 130 volts.

The Model 955 also has a verifier switch and light. When the verifier switch is in the ON position, the verifier light identifies materials which are protected with active 3M Tattle-Tape security strips.

Set the voltage selection switch to the 230 position when operating from 200 to 240 volts.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 43)
Fig. 40 · 3M Library Security System 3M Accessories

Security strips and labels on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.

When items are returned, the security strips can be resensitized. Improperly resensitized items will not alarm when passed through the detection system.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 43)
Fig. 41 · 3M Library Security System 3M Accessories
Show 4 more labels / short text on this page
Installation · Description/Characteristics · Voltage Selection · Model 955
Page 44 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 44 · click to enlarge
Page 44

3M Accessories 3M Library Security System

Select the Sensitize mode.

Select the Desensitize mode.

Place the spine of the marked book or an edge of a compact disc in the cradle of the bookcheck.

Place the spine of a marked book or a compact disc in the cradle of the bookcheck.

Slide the item to the left. As the item passes the optical trigger an audible signal (thump) will indicate the 3M Tattle-Tape security strip has been resensitized.

Slide the item to the left. As the item passes the optical trigger, an audible signal (thump) will indicate the 3Mt Tattle-Tapet Security Strip has been desensitized.

The orange verifier light will also turn on, confirming that the security strip has been properly resensitized. If the verifier light does not turn on, then the item is not marked with a 3M Tattle-Tape security strip.

The orange verifier light will also turn off, confirming that the security strip has been properly desensitized.

To ensure items will be properly desensitized, do not place more than one item at a time in the cradle of the Model 955.

To ensure that items will be properly resensitized, do not place more than one item at a time in the cradle of the Model 955.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 44)
Fig. 42 · 3M Accessories 3M Library Security System
3M 2301 — 3M Accessories 3M Library Security System diagram (page 44)
Fig. 43 · 3M Accessories 3M Library Security System
3M 2301 — 3M Accessories 3M Library Security System diagram (page 44)
Fig. 44 · 3M Accessories 3M Library Security System
Show 4 more labels / short text on this page
Operating Instructions · Resensitizing Security Strips · Desensitizing Security Strips · Desensitize Sensitize
Page 45 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 45 · click to enlarge
Page 45

3M Library Security System 3M Accessories

Verifying that materials are protected with 3Mt Tattle-Tapet Security Strips

Problem: The optical sensor area may have accumulated dust.

When the VERIFIER switch is in the ON position, the verifier light will identify which items in your collection are protected with 3Mt Tattle-Tapet security strips.

Solution: Clean this area by blowing or brushing dust from the optical sensors.

! Caution To reduce the risk of electrical shock, do not use liquids to clean the optical sensor.

To verify that an item is protected with a 3M security strip, resensitize the item as described on the previous page.

Make sure the Sensitize/Desensitize switch is in the SENSITIZE position.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 45)
Fig. 45 · 3M Library Security System 3M Accessories

Place the item in the center of the Model 955 with the item gently touching the vertical portion of the unit.

If the item is protected, the verifier will light. If the verifier does not light, then you will want to install a 3M Tattle-Tape security strip to protect the item.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 45)
Fig. 46 · 3M Library Security System 3M Accessories

Resetting the circuit breaker

The Model 955 bookcheck will not operate if the circuit breaker is open.

S Reset the circuit breaker on the back of the bookcheck one time.

S If the bookcheck does not operate correctly after resetting the circuit breaker one time, call 3M service at 1-800-328-0067.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 45)
Fig. 47 · 3M Library Security System 3M Accessories

No desensitizing or resensitizing

SymptomThe Model 955 will not desensitize or

resensitize any strip.

D The Model 955 fails to operate or “thump.”

Problem: The Model 955 is not connected to a working power outlet.

Solution: Plug the Model 955 into a working power outlet.

Optical Sensor Area · Troubleshooting · Circuit Breaker

Page 46 of the 3M 2301 user manual — B1
Page 46 · click to enlarge
Page 46

3M Accessories 3M Library Security System

Security Strips Used with the 3Mt Bookcheck Model 955

Typical Items Used with the 3M Bookcheck Model 955

3Mt Tattle-Tapet Security Strips

B1

B2

DCD-2

Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least 6 inches [150 mm] away from the 3M Model 955 surface to prevent magnetic damage.

The Model 955 should be installed away from areas which are readily accessible to patrons.

Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a grease cutting cleaner. Rub on the surface until clean and wipe dry.

Security Strip Storage Conditions

Store security strips at 50 -- 90 F [10 -- 32 C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Show 8 more labels / short text on this page
Books · Magazines · Periodicals · Compact discs · Records · Security Strip Application · Exceptions · Cleaning
Page 47 of the 3M 2301 user manual — 966--02RD
Page 47 · click to enlarge
Page 47

3M Library Security System 3M Accessories

4.9 3Mt Bookcheck Model 966 (Not For Use With Recorded Magnetic Media)

The Model 966 is designed to be installed in the circulation counter. It is also designed to be reversible, allowing you to process materials in a right-to-left or left-to-right motion. However, once installed in the counter, materials can be processed in one direction only. The library staff should indicate their preference of direction to the 3M service representative during the installation.

The 3Mt Bookcheck Model 966 is designed to desensitize and resensitize 3Mt Tattle-Tapet Security Strips. This includes strips applied in or on books, magazines, periodicals, and compact discs.

The Model 966 is not intended to be used with recorded magnetic media such as audio cassettes, video cassettes or computer software.

The library is responsible for cutting the mounting hole for the Model 966 in the circulation counter top and for mounting the Model 966 to the counter. Instructions for completing this portion of the installation are included with the Model 966.

The Model 966 also has a verifier switch and light. When the verifier switch is in the ON position, the verifier light identifies materials which are protected with active 3M Tattle-Tape security strips.

Once the Model 966 is mounted in the counter, the 3M service representative will complete the electrical installation of the Model 966.

Security strips and labels on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.

Do not plug the unit into a power outlet until the 3M service representative has completed the wiring.

When items are returned, the security strips can be resensitized. Improperly resensitized items will not alarm when passed through the detection system.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 47)
Fig. 48 · 3M Library Security System 3M Accessories

Warning

3M 2301 — Warning diagram (page 47)
Fig. 49 · Warning

966--02RD

Installation · Description/Characteristics · Model 966

Page 48 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 48 · click to enlarge
Page 48

3M Accessories 3M Library Security System

Select the Sensitize mode.

Select the Desensitize mode.

Place the spine of a protected book or a compact disc on the flat surface of the Model 966.

Place the spine of a protected book or a compact disc on the flat surface of the Model 966.

Slide the item to be sensitized in the direction of the arrow while gently touching the item against the vertical portion of the unit.

Slide the item to be desensitized in the direction of the arrow while gently touching the item against the vertical portion of the unit.

As the item passes the optical trigger, an audible signal (thump) will indicate that the 3M Tattle-Tape security strip has been sensitized.

As the item passes the optical trigger, an audible signal (thump) will indicate that the 3Mt Tattle-Tapet Security Strip has been desensitized.

To confirm that the security strip has been properly sensitized, move the item to the center of the unit and the orange verifier light should turn on. If the verifier light does not turn on, then the item is not protected with a 3M Tattle-Tape security strip.

The orange verifier light will also turn off, confirming that the security strip has been properly desensitized.

To ensure that items are properly desensitized, do not place more than one item at a time on the Model 966.

To ensure that items are properly sensitized, do not place more than one item at a time on the Model 966.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 48)
Fig. 50 · 3M Accessories 3M Library Security System
3M 2301 — 3M Accessories 3M Library Security System diagram (page 48)
Fig. 51 · 3M Accessories 3M Library Security System
3M 2301 — 3M Accessories 3M Library Security System diagram (page 48)
Fig. 52 · 3M Accessories 3M Library Security System

Incorrect Methods of Sensitizing and Desensitizing

Show 4 more labels / short text on this page
Operating Instructions · Resensitizing Security Strips · Desensitizing Security Strips · Desensitize Sensitize
Page 49 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 49 · click to enlarge
Page 49

3M Library Security System 3M Accessories

Verifying that materials are protected with 3Mt Tattle-Tapet Security Strips

No desensitizing or resensitizing

When the VERIFIER switch is in the ON position, the verifier light will identify which items in your collection are protected with 3Mt Tattle-Tapet security strips.

SymptomThe Model 966 will not desensitize or

resensitize any strip.

The Model 966 fails to operate or “thump”.

To verify that an item is protected, resensitize the item as described earlier.

Problem: The Model 966 is not connected to a working power outlet.

Make sure the Sensitize/Desensitize switch is in the SENSITIZE position.

Solution: Plug the Model 966 into a working power outlet.

Place the item in the center of the Model 966 with the item gently touching the vertical portion of the unit.

Problem: The optical sensor area may have accumulated dust.

If the item is protected, the verifier will light. If the verifier does not light, then you will want to install a 3M Tattle-Tape security strip to protect the item.

Solution: Clean this area by blowing or brushing dust from the optical sensors.

! Caution To reduce the risk of electrical shock, do not use liquids to clean the optical sensor.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 49)
Fig. 53 · 3M Library Security System 3M Accessories
3M 2301 — 3M Library Security System 3M Accessories diagram (page 49)
Fig. 54 · 3M Library Security System 3M Accessories
3M 2301 — 3M Library Security System 3M Accessories diagram (page 49)
Fig. 55 · 3M Library Security System 3M Accessories

Resetting the circuit breaker

The Model 966 will not operate if the circuit breaker is open.

S Reset the circuit breaker on the back of the Model 966 one time.

S If the Model 966 does not operate correctly after resetting the circuit breaker one time, call 3M service at 1-800-328-0067.

Troubleshooting · Optical Sensor

Page 50 of the 3M 2301 user manual — B1
Page 50 · click to enlarge
Page 50

3M Accessories 3M Library Security System

Security Strips Used with the 3Mt Bookcheck Model 966

Typical Items Used with the 3M Model 966 In-Counter Bookcheck

3Mt Tattle-Tapet Security Strips

B1

B2

DCD-2

Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least 6 inches [150 mm] away from the 3M Model 966 surface to prevent magnetic damage.

Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a grease cutting cleaner. Rub on the surface until clean and wipe dry.

Security Strip Storage Conditions

Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Show 7 more labels / short text on this page
Books · Magazines · Periodicals · Compact discs · Security Strip Application · Exceptions · Cleaning
Page 51 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 51 · click to enlarge
Page 51

3M Library Security System 3M Accessories

4.10 3Mt On-Counter Desensitizer Model 763 (For Use With Recorded Magnetic Media)

To desensitize security strips:

Draw the marked item across the surface of the Model 763. Make sure the strips are against the back or horizontal surface of the unit. Place video tapes against the back of the unit as shown in the following example.

The 3Mt On-Counter Desensitizer Model 763 is designed to desensitize 3Mt Tattle-Tapet Security Strips. This includes security strips which have been surface-applied to audio and video cassettes, and prepackaged computer software.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 51)
Fig. 56 · 3M Library Security System 3M Accessories

This device is not intended to desensitize security strips which have been applied directly to computer software, as the disks may be damaged.

Security strips on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 51)
Fig. 57 · 3M Library Security System 3M Accessories

Place audio tapes on the horizontal surface of the unit as shown in the following example.

3M 2301 — 3M Library Security System 3M Accessories diagram (page 51)
Fig. 58 · 3M Library Security System 3M Accessories

The 3M Model 763 is a moveable, non-electric, on-counter device which requires no installation. However, the 3M Model 763 should be used and stored away from areas which are readily accessible to customers.

Only one pass is necessary to fully desensitize a security strip.

To avoid damage to credit cards or computer software, do not permit credit cards or computer disks to make direct contact with the 3M Model 763.

Operating Instructions · Description/Characteristics · Installation

Page 52 of the 3M 2301 user manual — DAC-1
Page 52 · click to enlarge
Page 52

3M Accessories 3M Library Security System

Security Strips Used with the 3Mt Desensitizer Model 763

Typical Items Used with the 3M Desensitizer Model 763

3Mt Tattle-Tapet Security Strips

DAC-1

DVM-1

DSA-1

Security strips should be applied only to surfaces which are flat, clean, dry, and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

To avoid damage to credit cards or computer software, do not permit credit cards or computer disks to make direct contact with the 3M Model 763.

Computer software disks should be enclosed in a box or case to keep disks at least 1/4I (6 mm) from the 3M Model 763 surface.

The 3M Model 763 should be used and stored away from areas which are readily accessible to customers.

Security Strip Storage Conditions

Store security strips at 50_ -- 90_F (10_ -- 32_C) and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security system to be defeated.

Show 7 more labels / short text on this page
Records · Audio cassettes · Video cassettes · Boxed computer software · Compact discs · Security Strip Application · Exceptions
Page 53 of the 3M 2301 user manual — Model 764
Page 53 · click to enlarge
Page 53

3M Library Security System 3M Accessories

4.11 3Mt On-Counter Resensitizer Model 764 (Not For Use With Recorded Magnetic Media)

sliding the printed material. Connect the device to an AC power outlet. For an AC voltage range of 100 -- 120 VAC, use a 120 VAC 60 Hz unit, and for an AC voltage range of 200 -- 240 VAC, use a 220 VAC 50 Hz unit.

The Model 764 is a stand-alone on-counter resensitizer. It is used to resensitize 3Mt Tattle-Tapet Security Strips that have been applied to books, magazines, and other print media or to compact disks. Properly resensitized strips will set off an alarm when carried through a 3Mt Detection System. The Model 764 is powered from an AC power outlet.

System placement relative to interfering objects:

Magnetic Material:Keep all MAGNETICALLY

RECORDED MATERIALS, audio and video cassettes, and computer disks at least 6 inches [150 mm] from the M764 Resensitizer.

Computers (CRT) Keep all computers (CRTs) at least

36 inches [914 mm] from the M764 Resensitizer.

Physical:

Bright Lights: Keep the Model 764 out of direct sunlight or other bright light. A change in the amount of light detected by the unit may cause false triggering.

Depth: 5.5 in. [140 mm] Width: 12.25 in. [311 mm] Height: 4.38 in. [111 mm] Weight: 14.3 lbs. [6,5 kg] Shipping Weight: 17.0 lbs. [7,7 kg]

AC Power120 VAC 60 Hz (T5L250V fuse), 5A 220 VAC 50 Hz (Fuse 2.5A)

To avoid damage to credit cards or computer software: Do not attempt to resensitize security strips which have been applied directly to computer software. Do not permit credit cards or computer software disks to make direct contact with the 3M Model 764.

Resensitizing Books or Other Print Media

Slide the marked item from right to left along the front of the Model 764 as shown below. The spine of the marked item must be in contact with the front surface.

Model 764

3M 2301 — Model 764 diagram (page 53)
Fig. 59 · Model 764

The Model 764 is a stand-alone on-counter device. It can be set on any non-metallic table or cart top. The Model 764 may produce audible noise and/or vibration if placed within 0.8 inches [20 mm] of metal objects or surfaces. A mounting base option is available that eliminates this situation.

1. Start the pass with the marked item completely to the right of the Model 764.
2. Check that the indicator light turns on as the item is slid to the left.
3. Continue sliding the item to the left until it has passed across the entire front surface of the unit. To ensure that processing is completed, the indicator light must turn off at the end of the pass.

For proper operation, the printed material must be moved across the front of the Model 764, so there must be adequate space on either side of the device for

Show 5 more labels / short text on this page
Description/Characteristics · Specifications · Operating Instructions · Indicator Light · Installation
Page 54 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 54 · click to enlarge
Page 54

3M Accessories 3M Library Security System

Resensitizing Compact Disks (CDs)

The procedure for resensitizing CDs is the same as for books, except: the CD must be positioned upright as shown below and two passes must be made.

1. Pass the CD across the front surface of the Model 764 once.
3M 2301 — 3M Accessories 3M Library Security System diagram (page 54)
Fig. 60 · 3M Accessories 3M Library Security System
2. Rotate the CD clockwise or counterclockwise 180 degrees so the bottom is now on top.
3. Pass the CD across the Model 764 a second time.
3M 2301 — 3M Accessories 3M Library Security System diagram (page 54)
Fig. 61 · 3M Accessories 3M Library Security System
3M 2301 — 3M Accessories 3M Library Security System diagram (page 54)
Fig. 62 · 3M Accessories 3M Library Security System
3M 2301 — 3M Accessories 3M Library Security System diagram (page 54)
Fig. 63 · 3M Accessories 3M Library Security System

Spine of Material not against Model 764

3M 2301 — 3M Accessories 3M Library Security System diagram (page 54)
Fig. 64 · 3M Accessories 3M Library Security System
4. The Model 764 has been designed for a comfortable processing speed. The photocell must be unblocked for a short time (approximately 1.5 seconds) between books.
5. The speed with which material is processed can be increased by stacking printed materials up to the height of the vertical front surface of the unit. This is especially helpful for thin materials such as periodicals.

If the indicator light will not turn on during a proper pass, check the power connection for the Model 764. If the power connection is good, disconnect the power cord from the unit, pull out the fuse holder and check the fuse. A spare fuse is provided with each new Model 764. This unit is not otherwise operator serviceable.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 54)
Fig. 65 · 3M Accessories 3M Library Security System
Show 5 more labels / short text on this page
Wrong Direction · Center Start · Troubleshooting · Indicator Light · Photocell
Page 55 of the 3M 2301 user manual — DCD-2
Page 55 · click to enlarge
Page 55

3M Library Security System 3M Accessories

3M 2301 — 3M Library Security System 3M Accessories diagram (page 55)
Fig. 66 · 3M Library Security System 3M Accessories

Typical Items Used with the 3M On-Counter Resensitizer Model 764

In the U.S., the Model 764 is not serviced at the customer site. If a unit fails, it is replaced. When the replacement unit is received, the user packages the failed unit in the shipping carton and returns it to 3M. For assistance or more information on this program, please call the 3M National Service Center, 1 (800) 328-0067.

International users should call the 3M subsidiary in their area for information on local service.

Keep credit cards, recorded magnetic media (audio cassettes, video cassettes, computer software), stem-wind and self-wind wrist watches at least 6 inches [150 mm] away from the 3M Model 764 surface to prevent magnetic damage.

Security Strips Used with the 3Mt On-Counter Resensitizer Model 764

3Mt Tattle-Tapet Security Strips

B1

B2

Security Strip Storage Conditions

DCD-2

Store security strips at 50 -- 90F [10 -- 32C] and at 20 -- 70% relative humidity.

Store security strips in a clean area and out of direct sunlight. Rotate stock.

Security strips should always be applied to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a grease cutting cleaner. Rub on the surface until clean and wipe dry.

Show 8 more labels / short text on this page
Service · Books · Magazines · Periodicals · Compact discs · Exceptions · Security Strip Application · Cleaning
Page 56 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 56 · click to enlarge
Page 56

3M Accessories 3M Library Security System

4.12 3M t Model 494 Locking Exit or Entrance Gate

Problem: Gate will not lock or remains locked. Gate closes too quickly (less than 4 seconds) or too slowly (more than 7 seconds).

The 3M Model 494 is designed to restrain patrons during an alarm. Gates are shipped from the factory to open with a clockwise rotation but may be modified to open with a counterclockwise rotation.

Solution: Place service call.

Problem: Gate arm does not return to the correct closed position (perpendicular to the gate base).

The locking mechanism is controlled by an alarm signal and power from the detection system.

When a strip is detected in the detection system and an alarm is created, the exit gate will lock in the closed position blocking patron travel through the exit corridor. The gate remains locked for the alarm period. If the gate is locked during an emergency, the gate arm can be forced open with a force of 15 -- 25 lbs. [6,8 -- 11,3 kg].

Solution:

1. If the gate arm does not return far enough, as shown below, apply sufficient pressure in the direction shown to return the gate to the correct position.

Gates are not available on the Detection System Model 3500.

3M 2301 — 3M Accessories 3M Library Security System diagram (page 56)
Fig. 67 · 3M Accessories 3M Library Security System

Force Gate Arm to Correct Position

Gate Arm Stops Here

Locking exit gates may be installed on either side of the detection system. For single corridor systems, the gate box may be located at the end of either panel. For dual corridor systems, two gates are required and the gate boxes must be located at the ends of the two outside panels.

The locking exit gate is designed to be installed by 3M factory trained service personnel.

2. If the gate arm returns too far, as shown below, open the gate until it reaches the stop. Apply sufficient pressure (15 -- 25 lbs. [6,8 -- 11,3 kg] of force) to move the gate arm an additional amount. Release the gate arm and check its position. Repeat the procedure as necessary.
3M 2301 — 3M Accessories 3M Library Security System diagram (page 56)
Fig. 68 · 3M Accessories 3M Library Security System
3M 2301 — 3M Accessories 3M Library Security System diagram (page 56)
Fig. 69 · 3M Accessories 3M Library Security System

Force Gate Arm to Correct Position

Gate Arm Stops Here

Show 6 more labels / short text on this page
Troubleshooting · Description/Characteristics · Installation · Correct Position · Locking Exit Gate · Correct Position
Page 57 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 57 · click to enlarge
Page 57

3M Library Security System 3M Accessories

4.13 3Mt SelfCheckt System Model 5210

S Multiple Book Detection prevents more than one item from being checked out on the same bar code

S Built-in photocells keep patrons from substituting materials

The system emulates the same procedures to process materials that librarians use. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip — all in a matter of seconds.

S Advanced technology raster laser scanner reads the entire bar code area, enabling it to read even worn codes

S Only desensitizes books when approved by the host circulation system

S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of transaction

If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.

S Simple to install wherever floor traffic demands

S Can be programmed with a wide variety of messages and instructions to fit most library situations

The 3M selfcheck system is compatible with many automated circulation systems.

S PIN numbers can be added for security against misuse of lost or stolen library cards

The system also features menus which allow you to make changes in a few minutes. You can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.

S Overall design and neutral beige color blends well into any library decor

The system operates much like automatic teller machines. For details, refer to the Operating Guide for the Model 5210.

S Automates library checkout, freeing staff time for other important tasks

The following diagram illustrates the components that the patron uses in the 3M selfcheck system.

S Built-in 3M Tattle-Tape security strip detection ensures that library security is not compromised

S Full-color graphics and user-friendly prompts are easy to follow

3M 2301 — 3M Library Security System 3M Accessories diagram (page 57)
Fig. 70 · 3M Library Security System 3M Accessories

Scanner to read bar codes

Color Monitor displays graphic instructions to patrons

Red scanning area where patrons place library cards and library materials to be scanned

Magnetic Card Reader (optional)

Printer for due date receipt

Show 6 more labels / short text on this page
Description/Characteristics · Operating Instructions · Features and Benefits · Cradle · Light Bar · Keypad
Page 58 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 58 · click to enlarge
Page 58

3M Accessories 3M Library Security System

4.14 3Mt SelfCheckt System Model 5220

S Full-color graphics and user-friendly prompts are easy to follow

S Multiple Book Detection prevents more than one item from being checked out on the same bar code

The SelfCheck system emulates the procedures used by librarians to process library materials. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved library patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip — all in a matter of seconds.

S Built-in photocells keep patrons from substituting materials

S Advanced technology raster laser scanner reads the entire bar code area, enabling it to read even worn codes

S Only desensitizes books when approved by the host circulation system

S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of a transaction

If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials are on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.

S Simple to install wherever floor traffic demands

S Can be programmed with a wide variety of messages and instructions to fit most library situations

The 3M selfcheck system is compatible with many automated circulation systems.

The system also features menus which allow librarians to make changes in a few minutes. They can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.

S PIN numbers can be added for security against misuse of lost or stolen library cards

S Overall design and neutral beige color blends well into any library decor

The system operates much like automatic teller machines. For details, refer to the Operating Guide for the Model 5210/5220.

S Automates library checkout, freeing staff time for other important tasks

S Built-in 3M Tattle-Tape security strip detection ensures that library security is not compromised

The following diagram illustrates the components that the patron uses in the 3M selfcheck system.

Scanner to read bar codes

3M 2301 — 3M Accessories 3M Library Security System diagram (page 58)
Fig. 71 · 3M Accessories 3M Library Security System

Color Monitor displays graphic instructions to patrons

Scanning area where pa- trons place library cards and library materials to be checked out.

Printer for due date receipt

Show 5 more labels / short text on this page
Description/Characteristics · Operating Instructions · Features and Benefits · Keypad · Cradle
Page 59 of the 3M 2301 user manual — 3M Library Security System 3M Accessories
Page 59 · click to enlarge
Page 59

3M Library Security System 3M Accessories

4.15 3Mt SelfCheckt System Model 6210

S Multiple Book Detection prevents more than one item from being checked out on the same bar code

S Built-in photocells keep patrons from substituting materials

The SelfCheck system Model 6210 emulates the procedures used by librarians to process library materials. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved library patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip — all in a matter of seconds.

S Advanced technology laser scanner reads the entire bar code area, enabling it to read even worn codes

S Only desensitizes books when approved by the host circulation system

S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of a transaction

If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials are on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.

S Simple to install wherever floor traffic demands

S Can be programmed with a wide variety of messages and instructions to fit most library situations

The 3M selfcheck system is compatible with many automated circulation systems.

S PIN numbers can be added for security against misuse of lost or stolen library cards

The system also features menus which allow librarians to make changes in a few minutes. They can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.

S Overall design and light gray color blends well into any library decor

The system operates much like automatic teller machines. For details, refer to the on-line Operating Guide for the Model 6210.

S Automates library checkout, freeing staff time for other important tasks

The following diagram illustrates the components that the patron uses in the 3M selfcheck system.

S User-friendly prompts and graphics are easy to follow

3M 2301 — 3M Library Security System 3M Accessories diagram (page 59)
Fig. 72 · 3M Library Security System 3M Accessories

Color monitor displays graphic instructions to patrons

Scanner to read bar codes

Receipt printer for due date receipt

Magnetic card reader (optional)

Video cassette unit to process VHS video tapes

Scanning area where patrons place library cards and library ma- terials to be scanned

Show 5 more labels / short text on this page
Description/Characteristics · Operating Instructions · Features and Benefits · Keypad · Cradle
Page 60 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 60 · click to enlarge
Page 60

3M Accessories 3M Library Security System

4.16 3M t SelfCheck t System Model 4210

S Multiple Book Detection prevents more than one item from being checked out on the same bar code

S Built-in photocells keep patrons from substituting materials

The SelfCheck system Model 4210 emulates the procedures used by librarians to process library materials. When a patron places a library card in the system, a scanner is activated that reads the bar code and then accesses the library circulation system. If he or she is an approved library patron, screen graphics appear that guide the patron through the check-out process. The system verifies that the item can be circulated, checks the item out, desensitizes the 3Mt Tattle-Tapet Security Strip and prints out a date due slip - all in a matter of seconds.

S Advanced technology laser scanner reads the entire bar code area, enabling it to read even worn codes

S Only desensitizes books when approved by the host circulation system

S Automatically prints out date due slips, giving patrons a handy record of transaction; can be programmed to print out slips singly or at end of a transaction

If patrons are not approved borrowers or there is some other problem or information to convey — such as fines owed or materials are on hold for them — the screen simply spells out the appropriate message or asks them to go to the front desk.

S Simple to install wherever floor traffic demands

S Can be programmed with a wide variety of messages and instructions to fit most library situations

The 3M selfcheck system is compatible with many automated circulation systems.

S PIN numbers can be added for security against misuse of lost or stolen library cards

The system also features menus which allow librarians to make changes in a few minutes. They can choose from a variety of different instructional messages and even add Personal Identification Numbers (PINs) to further improve security.

S Overall design and light gray color blends well into any library decor

The system operates much like automatic teller machines. For details, refer to the on-line Operating Guide for the Model 4210.

S Automates library checkout, freeing staff time for other important tasks

The following diagram illustrates the components that the patron uses in the 3M selfcheck system.

S User-friendly prompts and graphics are easy to follow

Scanner to read bar codes

3M 2301 — 3M Accessories 3M Library Security System diagram (page 60)
Fig. 73 · 3M Accessories 3M Library Security System

Magnetic card reader (optional)

Cradle Scanning area where patrons

place library cards and

Receipt printer for due date receipt

materials to be scanned

Video checkout unit - to process VHS video tapes

Keypad Black & white monitor displays graphic instruc- tions to patrons

Description/Characteristics · Operating Instructions · Features and Benefits

Page 61 of the 3M 2301 user manual — B1 B2 DS-B1-N DS-B2-N DCD-2
Page 61 · click to enlarge
Page 61

3M Library Security System 3M Accessories

4.17 3M t Staff Workstation Model 995

The staff workstation is designed to desensitize and resensitize the following 3Mt Tattle-Tapet Security Strips:

The 3Mt Staff Workstation Model 995 emulates the same processes the library staff follows to check in or out library items. The Model 995 is connected to an existing library terminal and consolidates several processing tasks.

B1 B2 DS-B1-N DS-B2-N DCD-2

The desensitizing and resensitizing deck can be surface or flush mounted.

S Reduces item handling S Enhances library security S No additional software S Compatible with most existing workstations S Checks items in or out S Magnetic media safe S Security sensitizing or desensitizing S Security verification S Scanner disabling S In or on counter installation

A scanner and a keyboard wedge are included with the Model 995 to scan item bar codes. This replaces scanning with a hand-held scanner, using a light pen, or entering the number on the keyboard.

For processing non-magnetic media, electronics in the Model 995 eliminate the need for separate resensitizing and desensitizing accessories.

With the flip of a switch, the operator can process recorded magnetic media such as audio cassettes, video cassettes, or computer software. Magnetic media may be processed by using the Model 995 to record the transaction in the library circulation system and an appropriate resensitizer or desensitizer to sensitize or desensitize the strip.

This system operates similar to the common check in and check out processes. For details, refer to the Staff Workstation Model 995 Operator’s Manual.

3M 2301 — B1 B2 DS-B1-N DS-B2-N DCD-2 diagram (page 61)
Fig. 74
Show 5 more labels / short text on this page
Description/Characteristics · Features and Benefits · Operating Instructions · Electronics Box · Scanner Switch
Page 62 of the 3M 2301 user manual — 3M Accessories 3M Library Security System
Page 62 · click to enlarge
Page 62

3M Accessories 3M Library Security System

Blank Page

Page 63 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 63 · click to enlarge
Page 63

3M t Tattle-Tape t Security Strips 3M Library Security System

Section 5. 3Mt Tattle-Tapet Security Strips Used with the 3Mt Detection System

To determine the recommended 3M stripping procedures for each strip type, please refer to the page(s) which describe the specific strip you are using.

3M offers a complete line of 3Mt Tattle-Tapet Security Strips which will allow you to protect a variety of items. Each of the security strips which can be used with the 3Mt Detection Systems is described in this section. The strips provide maximum protection and are most effective when 3M marking procedures are followed.

Security Strips Used with the 3M Detection Systems

B1 5-3 B2 5-5 DAC-1 5-7 DCD-2 5-9 DVM-1 5-11

Stripping Procedure · Description/Characteristics · Security Strips Page

Page 64 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 64 · click to enlarge
Page 64

3M t Tattle-Tape t Security Strips 3M Library Security System

5.1 Print Media Protection — 3M t Tattle-Tape t Security Strips: B1

1. Remove the liner from the security strip.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 64)
Fig. 75 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

The 3Mt B1 Security Strip is a security strip which may be secured inside the spine of a book.

Security strips on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.

The 3M B1 security strips should be applied and stored away from areas which are readily accessible to patrons.

2. Place 1/4 inch [6 mm] of the B1 security strip on the tip of the bayonet.

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 64)
Fig. 76 · 3M t Tattle-Tape t Security Strips 3M Library Securi…
3. Open the book so the book cover separates from the binding.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 64)
Fig. 77 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Installation in Books · Description/Characteristics · Security Strip Application

Page 65 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 65 · click to enlarge
Page 65

3M t Tattle-Tape t Security Strips 3M Library Security System

4. Start the bayonet into the book with the adhesive side of the security strip toward the book cover.

Desensitizers Used with 3Mt Tattle-Tapet B1 Security Strips

Push the bayonet between the book cover and the binding.

3Mt On-counter Model 930

3Mt Bookchecks Models 435, 950 and 955

Pull the bayonet through the book, stopping when the security strip disappears.

3Mt Bookcheck Model 966

3Mt In-counter Model 2004

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 65)
Fig. 78 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Resensitizers Used with 3M Tattle-Tape B1 Security Strips

3M Bookchecks Models 435, 950 and 955

3M Bookcheck Model 966

3Mt Handheld Resensitizer Model 951

3Mt On-counter Resensitizer Model 764

Typical Items Marked with 3M Tattle-Tape B1 Security Strips

5. Close the book and press along the outside of the spine to secure the security strip.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 65)
Fig. 79 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Security Strip Storage Conditions

Store security strips at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.

Keep security strips in a clean area and out of direct sunlight. Rotate stock.

Store the security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.

6. Pull the bayonet to release it from the security strip.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 65)
Fig. 80 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Hardcover books

Page 66 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 66 · click to enlarge
Page 66

3M t Tattle-Tape t Security Strips 3M Library Security System

5.2 Print Media Protection — 3M t Tattle-Tape t Security Strips: B2

1. Open the book to a page with a margin wide enough that the security strip will not cover the printing.

The 3Mt B2 Security Strips are designed to be placed between the pages of books or magazines.

Avoid pages where the book opens naturally.

Do not open the book wide enough that it will open to this page again.

Security strips on protected items must be properly desensitized so the items can be carried through the detection system without causing an alarm.

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 66)
Fig. 81 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

The 3M B2 security strips should be applied and stored away from areas which are readily accessible to patrons.

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

2. Remove the short liner from the security strip.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 66)
Fig. 82 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Installation in Books · Description/Characteristics · Security Strip Application

Page 67 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 67 · click to enlarge
Page 67

3M t Tattle-Tape t Security Strips 3M Library Security System

3. Grasp the long plastic liner and slide the security strip into the gutter, as deeply as possible.

Desensitizers Used with 3M Tattle-Tape B2 Security Strips

3Mt On-counter Model 930

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 67)
Fig. 83 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

3Mt Bookchecks Model 435, 950 and 955

3Mt Bookcheck Model 966

3Mt In-counter Model 2004

Resensitizers Used with 3M Tattle-Tape B2 Security Strips

3M Bookchecks Models 435, 950 and 955

3M Bookcheck Model 966

3Mt Handheld Resensitizer Model 951

4. Fold over a few pages and press along length of strip to secure in place.

3Mt On-counter Resensitizer Model 764

Typical Items Marked with 3M Tattle-Tape B2 Security Strips

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 67)
Fig. 84 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Security Strip Storage Conditions

Store security strips at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.

5. Open the book to the page with the strip. Pull the long liner from the strip. Turn the page and apply pressure to secure the second side of the security strip to the book.

Keep security strips in a clean area and out of direct sunlight. Rotate stock.

Store the security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 67)
Fig. 85 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Paperback books · Hardcover books · Periodicals

Page 68 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 68 · click to enlarge
Page 68

3M t Tattle-Tape t Security Strips 3M Library Security System

5.3 Audio Cassette Protection — 3M t Tattle-Tape t Security Strips: DAC-1

1. Remove the liner from the security strips.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 68)
Fig. 86 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

The 3Mt Tattle-Tapet DAC-1 Audio Cassette Security Strip and cover label are designed to be applied directly on audio cassettes.

Once applied, discreet protection and full circulation of audio cassettes is provided for the life of the marked item.

Security strips on protected cassettes must be properly desensitized so the cassettes can be carried through the detection system without causing an alarm.

2. Apply the security strip across the top of the label area on the audio cassette.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 68)
Fig. 87 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

The 3M Tattle-Tape DAC-1 security strips should be applied and stored away from areas which are readily accessible to patrons.

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

3. Press along the length of the security strip to secure it to the cassette.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 68)
Fig. 88 · 3M t Tattle-Tape t Security Strips 3M Library Securi…
4. Do not place the strip at the bottom of the audio cassette.

Marking Audio Cassettes · Description/Characteristics · Security Strip Application

Page 69 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 69 · click to enlarge
Page 69

3M t Tattle-Tape t Security Strips 3M Library Security System

5. Apply the cover label over the security strip.

Desensitizers Used with 3Mt Tattle-Tapet DAC-1 Security Strips

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 69)
Fig. 89 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

3Mt On-counter, magnetic media Model 2001

3Mt Handheld, magnetic media Model 766

3Mt On-counter, magnetic media Model 763

Resensitizers Used with 3M Tattle-Tape DAC-1 Security Strips

3M On-counter, magnetic media Model 2011

Typical Items Marked with 3M Tattle-Tape DAC-1 Security Strips

6. Press along the length of the cover label to secure it to the cassette.

Security Strip Storage Conditions

Store security strips at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.

Keep security strips in a clean area and out of direct sunlight. Rotate stock. Use security strips within 2 years of purchase to assure maximum adhesion of strip and cover label.

Store the DAC-1 security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized, resulting in poor detection. If this should happen, the strips may be fully resensitized prior to use.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Audio cassettes

Page 70 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 70 · click to enlarge
Page 70

3M t Tattle-Tape t Security Strips 3M Library Security System

5.4 Compact Disc Protection — 3M t Tattle-Tape t Security Overlay: DCD-2

2. Center the security overlay on the compact disc and hold it firmly in position.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 70)
Fig. 90 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

The 3Mt Tattle-Tapet DCD-2 Compact Disc Security Overlay is designed to be applied directly on CDs and CD-ROMs. The security strip and overlay are combined to simplify installation.

Once applied, protection and full circulation of CDs and CD-ROMs is provided for life of the marked item.

Security strips on protected compact discs must be properly desensitized so the compact discs can be carried through the detection system without causing an alarm.

3. Lift the smaller portion of the overlay and bend it back while removing the liner, rolling the adhesive surface of the overlay onto the CD surface.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 70)
Fig. 91 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

The 3M Tattle-Tape DCD-2 overlay should be applied and stored away from areas which are readily accessible to patrons.

DCD-2 overlays should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the overlay.

4. Remove the liner from the large portion of the overlay — as in step 3 — securing it to the CD surface.
1. Place the security strip/overlay on the label side of the compact disc.
5. Rub the entire surface of the overlay to securely bond it to the CD.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 70)
Fig. 92 · 3M t Tattle-Tape t Security Strips 3M Library Securi…
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 70)
Fig. 93 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

Description/Characteristics · Security Strip Application · Marking Compact Discs

Page 71 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 71 · click to enlarge
Page 71

3M t Tattle-Tape t Security Strips 3M Library Security System

Desensitizers Used with 3Mt Tattle-Tapet DCD-2 Overlay

Security Overlay Storage Conditions

Store security overlays at 50_ -- 90_F [10_ -- 32_C] and at 20 -- 70% relative humidity.

3Mt On-counter Model 930

3Mt Bookchecks Models 435, 950 and 955

Keep security overlays in a clean area and out of direct sunlight. Rotate stock. Use security strips within 2 years of purchase to assure maximum adhesion of overlay.

3Mt Bookcheck Model 966

3Mt Handheld Model 766 (must contact overlay)

Resensitizers Used with 3M Tattle-Tape DCD-2 Overlay

Store the security overlays at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.

3Mt Handheld Resensitizer Model 951

3M Bookchecks Models 435, 950 and 955

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

3M Bookcheck Model 966

3Mt On-counter Resensitizer Model 764

Typical Items Marked with 3M Tattle-Tape DCD-2 Overlay

Compact discs · CD-ROMs

Page 72 of the 3M 2301 user manual — DVM-1
Page 72 · click to enlarge
Page 72

3M t Tattle-Tape t Security Strips 3M Library Security System

5.5 Video Cassette Protection — 3M t Tattle-Tape t Security Strips: DVM-1

2. Apply the security strip near the edge of the recessed area on the top of the video cassette.
3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 72)
Fig. 94 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

DVM-1

The 3Mt Tattle-Tapet DVM-1 Video Cassette Security Strip and cover label are designed to be applied directly on video cassettes.

Once applied, discreet protection and full circulation of video cassettes are provided for the life of the marked items.

Security strips on protected cassettes must be properly desensitized so the cassettes can be carried through the detection system without causing an alarm.

3. Verify the strip is properly positioned. Press along the length of the security strip to secure it to the cassette.

The 3M Tattle-Tape DVM-1 security strips should be applied and stored away from areas which are readily accessible to patrons.

3M 2301 — DVM-1 diagram (page 72)
Fig. 95

Security strips should be applied only to surfaces which are flat, clean, dry and at room temperature. For maximum adhesion, minimize touching the adhesive surface of the security strips.

1. Remove the liner from the security strip.
4. Do not place the strip in the middle of the recessed area.

Description/Characteristics · Security Strip Application · Marking Video Cassettes

Page 73 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 73 · click to enlarge
Page 73

3M t Tattle-Tape t Security Strips 3M Library Security System

5. Apply the cover label over the security strip.

Desensitizers Used with 3Mt Tattle-Tapet DVM-1 Security Strips

3M 2301 — 3M t Tattle-Tape t Security Strips 3M Library Security System diagram (page 73)
Fig. 96 · 3M t Tattle-Tape t Security Strips 3M Library Securi…

3Mt On-counter, magnetic media Model 2001

3Mt Handheld, magnetic media Model 766

3Mt On-counter, magnetic media Model 763

Resensitizers Used with 3M Tattle-Tape DVM-1 Security Strips

3Mt On-counter, magnetic media Model 2011

Typical Items Marked with 3M Tattle-Tape DVM-1 Security Strips

6. Press along the length of the cover label to secure it to the cassette.

Compact disc jewel cases

Security Strip Storage Conditions

Store security strips at 50_ -- 90_F

[10_ -- 32_C] and at 20 -- 70% relative humidity.

Keep security strips in a clean area and out of direct sunlight. Rotate stock. Use security strips within 2 years of purchase to assure maximum adhesion of strip and cover label.

Store the security strips at least two feet [0,6 m] from all desensitizers or they may be partially or completely desensitized.

Never leave a desensitizer unattended. Access to a desensitizer may allow your security sys- tem to be defeated.

Video cassettes · Maps · Documents

Page 74 of the 3M 2301 user manual — 3M t Tattle-Tape t Security Strips 3M Library Security System
Page 74 · click to enlarge
Page 74

3M t Tattle-Tape t Security Strips 3M Library Security System

Blank Page

Page 75 of the 3M 2301 user manual — 6.2 Training Video
Page 75 · click to enlarge
Page 75

3M Library Security System Training Your Staff

Section 6. Training Your Staff

6.1 Operator’s Manual

This manual contains all of the information necessary to operate your 3M Library Security System, as well as supplemental information on handling alarms, ordering supplies, and training your staff. It also contains important information about security strips and circulation accessories.

A key element of any media loss prevention effort is a successful staff training program. Your 3Mt Library Security System will be much more effective with the active cooperation and participation of your entire library staff. We recommend that you periodically conduct formal training sessions, including the following elements to ensure its success:

Library personnel should be familiar with the manual and where to locate it so they can refer to it when necessary.

6-1 Familiarization with the Operator’s Manual

6.2 Training Video

6--2 View 3M Materials Flow Management Customer Training Video

The 3M Materials Flow Management Customer Training Video is provided along with the 3M Library Security System. We recommend you view this video prior to familiarizing yourself with other training information in this section.

6-3 Hands-on practice marking materials with security strips and labels and desensitizing and resensitizing security strips

6-4 Review of your library’s security policies

6-5 What to do when the alarm sounds

6-6 System Alarm Log

6-7 Addressing patron concerns

Show 4 more labels / short text on this page
6-8 Cleaning Instructions · 6-9 Troubleshooting Guide · 6-10 Ordering supplies · 6-11 Obtaining service
Page 76 of the 3M 2301 user manual — 6.4 Review Of Your Library’s Security Policies
Page 76 · click to enlarge
Page 76

3M Library Security System Training Your Staff

6.3 Hands-on Practice

6.5 What To Do When The Alarm Sounds

After reviewing the Operator’s Manual, your staff should get some actual hands-on experience in using the 3M Materials Flow Management products. We suggest you start by demonstrating the proper techniques for each stripping procedure. You may wish to conduct the actual practice as follows:

S Have your staff review the 3M Materials Flow Management Customer Training Video included in your customer training kit. The video includes an index and running time clock for easy review of specific sections of the video.

Sooner or later, it’s bound to happen. The audible alarm goes off. In multiple corridor systems, the light at the top of the panel will indicate in which corridor the alarm occurred. What you and your staff do in response to the alarm will depend on your library’s policy and the laws in your community. Always follow your library’s specific procedures. 3M offers these guidelines as a suggested supplement:

S Set up your circulation accessories on a table along with security strips and a few bayonets.

S Let each staff member practice installing the security strips that you use:

B1 Strips -- in the spine of

books B2 Strips -- in the gutter of

First, don’t panic. Remain calm and courteous. You can’t be positive that the person who triggered the alarm is stealing. Never accuse anyone of theft by word, by facial expression, or by tone of voice. The alarm may have been triggered accidentally, so always respond in a positive, non-threatening manner.

books DVM-1 Strips -- on video tapes DCD-2 Overlays -- on compact discs DAC-1 Cassette -- on audio cassettes Strips

S Let each staff member practice desensitizing and resensitizing materials with the appropriate circulation accessories.

6.4 Review Of Your Library’s Security Policies

Before practicing how to respond to alarms, your staff should be familiar with your library’s security policies as they relate to theft of materials. Your policy should be put in writing and kept in your training kit in addition to any procedures you already follow to keep your staff informed of security measures. It is particularly important for staff members to know what procedures your library follows when theft is suspected or when it is necessary to contact a local law enforcement agency.

A critical phase of staff training concerns the proper steps to take when the security system alarm sounds. The value of tact and courtesy when handling this delicate situation cannot be overemphasized. Your staff members should receive as much preparation as possible to make them feel comfortable. Only then will they be likely to deal successfully with patrons who activate the alarm.

Page 77 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 77 · click to enlarge
Page 77

3M Library Security System Training Your Staff

The library staff person mistakenly neglects to desensitize a marked item when checking out the patron’s materials, or the patron accidentally removes marked materials from the library.

The detection system is virtually free of false alarms. Occasionally the detection system may alarm and the staff will find that the patron does not have unauthorized library materials. The patron may have carried items with active strips into the library. “Unwanted alarms” are alarms caused by active security strips on items carried into the library. If the following items have active security strips, they may cause unwanted alarms:

After asking the patron to return to the counter, a typical response might be, “Excuse me, did I forget to check out one of your items?” — or — “Did you perhaps pick up one of the library’s books with your own things?” These are courteous questions, and they don’t accuse the patron of theft. Be sure to smile and ask the questions in a friendly, non-threatening manner.

S Books from another library or book store

S Audio and video cassettes from video rental and music stores

Process and desensitize all items again. If you discover an item that hasn’t been properly checked out, never accuse the patron of stealing. Simply act as if the error was an oversight — it more than likely was. If the patron causes the alarm to sound again, follow the policy that your library has established for possible theft of materials.

S Other items from retail stores

Other security system users may check out, lend, or sell protected items without desensitizing the security strips. These items will cause unwanted alarms as the patron enters or exits the library. Unwanted alarms will cause concern and added work for the library staff. Unwanted alarms are generally infrequent and will vary depending on the patrons and on the proximity of your library to locations that are releasing materials containing active security strips.

If a patron denies having any library materials after sounding the alarm, follow your library’s policy for theft.

Because it is not possible to distinguish between unwanted alarms and alarms with potential book loss, all responses to alarms must be consistent and follow your management policies. If patrons see no response to alarms, the detection system becomes less effective. When you decide that an active strip on an item from outside your library caused an alarm, follow these steps:

If a patron bolts and runs out of the library after sounding the alarm, follow your library’s policy for theft.

Responding to alarms is a sensitive situation, but can be handled confidently and effectively as long as your library has established procedures AND your staff has been fully trained in following them.

1. Explain the problem to the patron.
2. Verify that all of the patron’s library materials are properly checked out.
3. Allow the patron to exit the library.

Many patrons will learn from the experience and will not carry items that may cause alarms into the library.

Show 4 more labels / short text on this page
Scenario #1 · Unwanted Alarms · Scenario #2 · Scenario #3
Page 78 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 78 · click to enlarge
Page 78

3M Library Security System Training Your Staff

6.6 System Alarm Log

6.7 Addressing Patron Concerns

The System Alarm Log is used to keep a record of alarms that occur.

If your patrons express concern about the effect of the 3Mt Detection System on pacemakers, hearing aids, recorded magnetic media, you can respond that 3M researchers (in conjunction with the manufacturers of these items) have conducted extensive tests on 3M detection systems and have found them to be perfectly safe. The magnetic signal used by the detection panels to detect sensitized 3Mt Tattle-Tapet Security Strips is no stronger than that of an ordinary kitchen blender or a hair dryer.

For each alarm, record the information on the log. Keeping this log up-to-date provides a key tool for monitoring system activity. An up-to-date alarm log provides useful information for your management and your 3M service representative.

Page 79 of the 3M 2301 user manual — 3M Library Security Systems System Alarm Log
Page 79 · click to enlarge
Page 79

3M Library Security System Training Your Staff

1. Test 2.Upon entering 3.Failure to desensitize 4. Undetermined 5. Real alarm

3M 2301 — 3M Library Security System Training Your Staff diagram (page 79)
Fig. 97 · 3M Library Security System Training Your Staff

(1) Reason for Alarm:

3M Library Security Systems System Alarm Log

Date Time Patron · Alarm

Page 80 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 80 · click to enlarge
Page 80

3M Library Security System Training Your Staff

6.8 Cleaning Instructions

1. Turn the key switch to OFF.
2. Wait until the fan stops.

S Steps 3 through 6 are for washing the fan filter. Instead of washing the filter, it may be vacuumed without removing the grille. Washing is preferred because it results in a more thorough cleaning.

Turn off the security system prior to using liquid cleaners. Remove dirt and greasy buildup using towels or soft cloths which have been dampened with a common household grease-cutting liquid cleaner. We suggest a monthly cleaning to retain the best equipment appearance.

3. Remove the four thumb screws holding the fan grille.
4. Remove and wash the fan filter in water.

Photocell Lens and Reflector

5. Dry the fan filter.

At least once a month, wipe the photocell lens and reflector with a soft cloth dampened with water.

6. Reinstall the fan filter, grille, and four screws.
7. Return the key switch to ON.
3M 2301 — 3M Library Security System Training Your Staff diagram (page 80)
Fig. 98 · 3M Library Security System Training Your Staff

Over time, areas on accessories that come in constant contact with adhesive-backed tapes and labels will accumulate a build-up of adhesive. To remove adhesive build-up, clean the surface with a cloth dampened with rubbing alcohol (ethyl or isopropyl).

Fan Filter on Electronics Chassis

At least once every six months, clean the fan filter as follows:

Show 4 more labels / short text on this page
Lattice and Base · General Maintenance · Accessories (Desensitizers) · Model 3801/3802
Page 81 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 81 · click to enlarge
Page 81

3M Library Security System Training Your Staff

6.9 Troubleshooting Guide

3M 2301 — 3M Library Security System Training Your Staff diagram (page 81)
Fig. 99 · 3M Library Security System Training Your Staff

No alarm, no patron count, no diagnostic code in display window.

No power at wall outlet. Reset facility circuit breaker.

System unplugged. Plug in and wait two minutes for full operation.

System circuit breaker tripped. Reset the circuit breaker no more than three times. Call 3M Service if problem persists.

System failure. Place service call.

No alarm, diagnostic code 1, 2, 3, 4, 5, or 6 in window.

System failure. Place service call. Code number will be needed.

No alarm, patron count in window.

Strip desensitized. Test system with another marked object with a sensitized strip.

Model 2301, 2302 · Problem Cause Action

Page 82 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 82 · click to enlarge
Page 82

3M Library Security System Training Your Staff

Infrequent unwanted alarms.

Miscellaneous metallic objects. Infrequent, unwanted alarms are considered acceptable.

Protected material from other library or retail store.

Identify material that caused alarm.

Failure to desensitize strip properly. Check operator training procedures.

Frequent (daily) unwanted alarms.

Failure to desensitize strip properly. Follow correct check-out procedures outlined in 3M literature. Check operator training procedures.

Metallic object located too close to system.

Remove, maintain a minimum distance of 3 feet.

System failure. Place service call. Code number, if any, will be needed.

Reduced coverage, no alarm.

Metallic object located too close to system.

Remove, maintain a minimum distance of 3 feet.

Incomplete walk-through test. Retest by walking completely through the corridor. The light beam between the photocell and the reflector in the corridor must be interrupted.

Strip not detected. Retest marked object.

System failure. Place service call. Code number will be needed.

Diagnostic code 7 in window.

Metallic object located too close to lattice. Examples: metal window or door frames, desks, counters, shelves, waste baskets, etc.

Move metal object or system until minimum distance is approximately 3 feet.

Diagnostic code 8 in window.

Excessive electrical/electronic interference, generally caused by devices such as computers, CRTs, copiers, electronic fluorescent lights.

Decrease interference from device: Move device farther away from system. Turn device off. Use device with lower emissions. Shield device.

Problem Cause Action

Page 83 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 83 · click to enlarge
Page 83

3M Library Security System Training Your Staff

6.10 Troubleshooting Guide

No alarm, no patron count, no red power indicator on Electronic Enclosure.

No power at receptacle. Reset facility circuit breaker.

Power cord disconnected at receptacle.

Plug power cord in receptacle.

System fuse open. Replace fuse in power entry connector.

Power turned off at Electronics Enclosure.

Turn key switch to ON.

System failure. Place service call. (1-800-328-0067)

No alarm, no patron count, power indicator ON.

Processor requires reset. Turn key switch OFF, wait 5 seconds, then turn switch ON.

System failure. Place service call. (1-800-328-0067)

Model 3501, 3502 · Problem Cause Action

Page 84 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 84 · click to enlarge
Page 84

3M Library Security System Training Your Staff

No alarm, patron counter works.

Strips in book desensitized or missing.

Resensitize books, or install Tattletape in book.

System failure. Place service call. (1-800-328-0067)

Metal objects too close to panel. Move all metal to minimum distance of 18 inches from the panels.

Unwanted alarms. Protected material from other library/retail store.

Identify material that caused alarm.

Failure to desensitize marker properly.

Check desensitizing process and training.

Miscellaneous metallic objects. Infrequent unwanted alarms from some metal objects are possible.

System failure. Place service call. (1-800-328-0067)

Reduced coverage, no alarm, patron counter works.

Metal objects too close to panel. Move all metal objects to a minimum distance of 18 inches from panels.

Electrical interference. Remove possible sources of electrical interference such as computers, copiers, TVs, and electronic devices.

Incomplete walk-through test. Test the system by walking completely through just as a patron must.

Books not properly resensitized. Resensitize book, check sensitizing method and staff training.

System failure. Place service call. (1-800-328-0067)

Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor.

Metal objects too close to panel. Move all metal objects to a minimum of 3 feet from the panel.

Marked book or strips too close to panel.

Move marked books to a minimum of 3 feet from the panel.

Electrical interference. Eliminate source of interference.

System failure. Place service call. (1-800-328-0067)

Problem Cause Action

Page 85 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 85 · click to enlarge
Page 85

3M Library Security System Training Your Staff

6.11 Troubleshooting Guide

No alarm, no code in window.

No power at wall outlet. Reset facility circuit breaker.

Panel unplugged. Plug in and wait five minutes for full operation.

System circuit breaker tripped. Reset the circuit breaker no more than three times. Call 3M Service if problem persists.

Power turned off at system panel. Turn key switch to ON.

System failure. Place service call.

No alarm, code 3 in window.

Dirty fan filter. Clean fan filter.

System failure. Place service call.

No alarm, code 5 in window.

Metal objects such as carts of trash cans next to system.

Remove interfering objects. Pull power cord at wall plug. Wait ten seconds. Reinsert plug and wait five minutes for full operation.

No alarm, code 6 in win- dow.

Detection reduced due to presence of metal objects, computers, cash regis- ters, or electronic device next to sys- tem.

Check area directly next to panels. Move objects away. Retest system.

Model 3801, 3802 · Problem Cause Action

Page 86 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 86 · click to enlarge
Page 86

3M Library Security System Training Your Staff

No alarm, code 1, 2, 4, 7 or 8. System failure. Place service call. Code number will be needed.

No alarm, patron count in window.

Marker deactivated. Test system with another marked object with a sensitized strip.

Infrequent unwanted alarms.

Miscellaneous metallic objects. Infrequent, unwanted alarms are considered acceptable.

Protected material from other library or retail store.

Identify material that caused alarm.

Failure to desensitize marker properly.

Check operator training procedures.

Frequent (daily) unwanted alarms.

Failure to desensitize marker properly.

Follow correct check-out procedures outlined in 3M literature. Check operator training procedures.

Photocell or reflector lens dirty. Clean with soft cloth and water.

System failure. Place service call. Code number will be needed.

Reduced coverage, no alarm.

Metallic object located too close to system.

Remove, maintain a minimum distance of 2 feet.

Incomplete walk-through test. Retest by walking completely through the corridor. The light beam between the photocell and the reflector in the corridor must be interrupted.

Marker not detected. Retest marked object.

No alarm, code 9 in window.

System is in warm-up mode. Wait approximately 1 minute.

Problem Cause Action

Page 87 of the 3M 2301 user manual — 6.13 Obtaining Service
Page 87 · click to enlarge
Page 87

3M Library Security System Training Your Staff

6.12 Ordering Supplies

With NetscapeR, version 1.1 or later or MicrosoftR Internet Explorert, version 2.0 or later in the U.S., you can place service requests over the Internet. 3M will send you an automated confirmation of your request and then another confirmation when you are scheduled for service. The Internet service address is:

Be sure to budget annually for any supplies you might need. You should also budget for your Service Agreement renewal each year so that you are assured of getting the most cost-effective service for your 3Mt Detection System.

https://www.mmm.com/3mlibsvc

Remember . . . only when all of your library materials are marked with 3Mt Tattle-Tapet Security Strips, are you effectively protecting your materials from loss and assuring that all of them are available to your patrons when they’re needed.

In CanadaEnglish 1-800-268-6235
In your areaSales Service Supplies

To renew your supply of 3M Tattle-Tape strips and bayonets, simply call our customer service number:

In U.S.: 1/800-328-0067 (toll-free). Press 2 when instructed to do so.

When you call for service, please have the following information available:

1. Your name, name of your library or school, address, phone number.
In CanadaEnglish 1-800-268-6235
2. Model and serial number of the equipment to be worked on.
In your areaSales Service Supplies
3. Description of the problem. For example,

a. Is the malfunction in the detection system or desensitizer/resensitizer?

You can use this number if you want to order additional circulation accessories, detection equipment or other supplies.

b. Symptoms of the problem: poor or no detection; system alarms for no apparent reason; Bookcheck will not desensitize/resensitize; light does not work, etc.

To renew your Service Agreement, simply follow the instructions on the renewal notice you receive in the mail 90 days prior to the expiration of your current Service Agreement.

c. What is the diagnostic code indicated in the Status Display Window located on the side of the detection panel?

6.13 Obtaining Service

3M has a nationwide service network to help in the event you experience any difficulties with your 3M detection system. Simply call our service number:

The service representative will discuss the problem with you and attempt to solve it on the telephone. If a service call is necessary, a 3M service technician will be quickly dispatched to your library.

In U.S.: 1/800-328-0067 (toll-free, 24 hours a day). Press 1 when instructed to do so.

Français 1-800-567-3193 · Français 1-800-567-3193

Page 88 of the 3M 2301 user manual — 3M Library Security System Training Your Staff
Page 88 · click to enlarge
Page 88

3M Library Security System Training Your Staff

Blank Page

Page 89 of the 3M 2301 user manual — 1-800-328-0067
Page 89 · click to enlarge
Page 89

3M Library Security System Service

Section 7. Service

To request service, call the 3M National Service Center.

1-800-328-0067

Press 1 when instructed to do so.

Provide system model and serial numbers.

Model Number Serial Number

Page 90 of the 3M 2301 user manual — 3M Library Security System Service
Page 90 · click to enlarge
Page 90

3M Library Security System Service

Blank Page

Page 91 of the 3M 2301 user manual — IMPORTANT NOTICE TO PURCHASER:
Page 91 · click to enlarge
Page 91

IMPORTANT NOTICE TO PURCHASER:

that, in 3M’s sole judgment, the performance or reliability is adversely affected thereby, or which is subjected to accident, misuse or neglect.

THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, indirect, or consequential, arising out of the sale, use, or misuse of 3M Library System products, or the user’s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE.

3M warrants that the 3Mt Library Security System will be free of defects in material and manufacture for a period of 90 days from the date of installation by 3M. Provided the system has been properly installed, operated, and maintained by purchaser, 3M will, at 3M’s option, repair, replace or refund the purchase price of such quantity of product determined to be defective. This warranty shall not apply to any system or component which has been repaired or modified by persons not authorized by 3M so

Statements or recommendations not contained herein shall have no force of effect unless in an agreement signed by an authorized representative of 3M. 3M reserves the right to make any changes in the design or construction of its products without obligation in respect to products previously sold and delivered.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No alarm, no patron count, no diagnostic code in display window.No power at wall outlet.Reset facility circuit breaker. p.81
No alarm, no patron count, no diagnostic code in display window.System unplugged.Plug in and wait two minutes for full operation. p.81
No alarm, no patron count, no diagnostic code in display window.System circuit breaker tripped.Reset the circuit breaker no more than three times. Call 3M Service if problem persists. p.81
No alarm, no patron count, no diagnostic code in display window.System failure.Place service call. p.81
No alarm, diagnostic code 1, 2, 3, 4, 5, or 6 in window.System failure.Place service call. Code number will be needed. p.81
No alarm, patron count in window.Strip desensitized.Test system with another marked object with a sensitized strip. p.81
Infrequent unwanted alarms.Miscellaneous metallic objects.Infrequent, unwanted alarms are considered acceptable. p.82
Infrequent unwanted alarms.Protected material from other library or retail store.Identify material that caused alarm. p.82
Infrequent unwanted alarms.Failure to desensitize strip properly.Check operator training procedures. p.82
Frequent (daily) unwanted alarms.Failure to desensitize strip properly.Follow correct check-out procedures outlined in 3M literature. Check operator training procedures. p.82
Frequent (daily) unwanted alarms.Metallic object located too close to system.Remove, maintain a minimum distance of 3 feet. p.82
Frequent (daily) unwanted alarms.System failure.Place service call. Code number, if any, will be needed. p.82
Reduced coverage, no alarm.Metallic object located too close to system.Remove, maintain a minimum distance of 3 feet. p.82
Reduced coverage, no alarm.Incomplete walk-through test.Retest by walking completely through the corridor. The light beam between the photocell and the reflector in the corridor must be interrupted. p.82
Reduced coverage, no alarm.Strip not detected.Retest marked object. p.82
Reduced coverage, no alarm.System failure.Place service call. Code number will be needed. p.82
Diagnostic code 7 in window.Metallic object located too close to lattice. Examples: metal window or door frames, desks, counters, shelves, waste baskets, etc.Move metal object or system until minimum distance is approximately 3 feet. p.82
Diagnostic code 8 in window.Excessive electrical/electronic interference, generally caused by devices such as computers, CRTs, copiers, electronic fluorescent lights.Decrease interference from device: Move device farther away from system. Turn device off. Use device with lower emissions. Shield device. p.82
No alarm, no patron count, no red power indicator on Electronic Enclosure.No power at receptacle.Reset facility circuit breaker. p.83
No alarm, no patron count, no red power indicator on Electronic Enclosure.Power cord disconnected at receptacle.Plug power cord in receptacle. p.83
No alarm, no patron count, no red power indicator on Electronic Enclosure.System fuse open.Replace fuse in power entry connector. p.83
No alarm, no patron count, no red power indicator on Electronic Enclosure.Power turned off at Electronics Enclosure.Turn key switch to ON. p.83
No alarm, no patron count, no red power indicator on Electronic Enclosure.System failure.Place service call. (1-800-328-0067) p.83
No alarm, no patron count, power indicator ON.Processor requires reset.Turn key switch OFF, wait 5 seconds, then turn switch ON. p.83
No alarm, no patron count, power indicator ON.System failure.Place service call. (1-800-328-0067) p.83
No alarm, patron counter works.Strips in book desensitized or missing.Resensitize books, or install Tattletape in book. p.84
No alarm, patron counter works.System failure.Place service call. (1-800-328-0067) p.84
No alarm, patron counter works.Metal objects too close to panel.Move all metal to minimum distance of 18 inches from the panels. p.84
Unwanted alarms.Protected material from other library/retail store.Identify material that caused alarm. p.84
Unwanted alarms.Failure to desensitize marker properly.Check desensitizing process and training. p.84
Unwanted alarms.Miscellaneous metallic objects.Infrequent unwanted alarms from some metal objects are possible. p.84
Unwanted alarms.System failure.Place service call. (1-800-328-0067) p.84
Reduced coverage, no alarm, patron counter works.Metal objects too close to panel.Move all metal objects to a minimum distance of 18 inches from panels. p.84
Reduced coverage, no alarm, patron counter works.Electrical interference.Remove possible sources of electrical interference such as computers, copiers, TVs, and electronic devices. p.84
Reduced coverage, no alarm, patron counter works.Incomplete walk-through test.Test the system by walking completely through just as a patron must. p.84
Reduced coverage, no alarm, patron counter works.Books not properly resensitized.Resensitize book, check sensitizing method and staff training. p.84
Reduced coverage, no alarm, patron counter works.System failure.Place service call. (1-800-328-0067) p.84
Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor.Metal objects too close to panel.Move all metal objects to a minimum of 3 feet from the panel. p.84
Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor.Marked book or strips too close to panel.Move marked books to a minimum of 3 feet from the panel. p.84
Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor.Electrical interference.Eliminate source of interference. p.84
Alarm/Inhibit indicator illuminated or intermittent with no traffic in corridor.System failure.Place service call. (1-800-328-0067) p.84
No alarm, no code in window.No power at wall outlet.Reset facility circuit breaker. p.85
No alarm, no code in window.Panel unplugged.Plug in and wait five minutes for full operation. p.85
No alarm, no code in window.System circuit breaker tripped.Reset the circuit breaker no more than three times. Call 3M Service if problem persists. p.85
No alarm, no code in window.Power turned off at system panel.Turn key switch to ON. p.85
No alarm, no code in window.System failure.Place service call. p.85
No alarm, code 3 in window.Dirty fan filter.Clean fan filter. p.85
No alarm, code 3 in window.System failure.Place service call. p.85
No alarm, code 5 in window.Metal objects such as carts of trash cans next to system.Remove interfering objects. Pull power cord at wall plug. Wait ten seconds. Reinsert plug and wait five minutes for full operation. p.85
No alarm, code 6 in win- dow.Detection reduced due to presence of metal objects, computers, cash regis- ters, or electronic device next to sys- tem.Check area directly next to panels. Move objects away. Retest system. p.85
No alarm, code 1, 2, 4, 7 or 8.System failure.Place service call. Code number will be needed. p.86
No alarm, patron count in window.Marker deactivated.Test system with another marked object with a sensitized strip. p.86
Infrequent unwanted alarms.Failure to desensitize marker properly.Check operator training procedures. p.86
Frequent (daily) unwanted alarms.Failure to desensitize marker properly.Follow correct check-out procedures outlined in 3M literature. Check operator training procedures. p.86
Frequent (daily) unwanted alarms.Photocell or reflector lens dirty.Clean with soft cloth and water. p.86
Frequent (daily) unwanted alarms.System failure.Place service call. Code number will be needed. p.86
Reduced coverage, no alarm.Metallic object located too close to system.Remove, maintain a minimum distance of 2 feet. p.86
Reduced coverage, no alarm.Marker not detected.Retest marked object. p.86
No alarm, code 9 in window.System is in warm-up mode.Wait approximately 1 minute. p.86

Ask about the 3M 2301

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the 3M 2301

Be the first to ask — other owners or our team will answer.

Original document

3M 2301 manual PDF

91 pages·819 KB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…