User’s Guide Guía del usuario Mode d’emploi Bedienungsanleitung Guida dell’utilizzatore


Removing and Replacing the Calculator’s Cover
Always slide the unit into the cover with the unit’s display end first. Never slide the keyboard end of the unit into the cover.


Be sure to read the following safety precautions before using this calculator. Keep this manual handy for later ref- erence.
This symbol is used to indicate information that can result in personal injury or material damage if ignored. Batteries







Key Layout

17 12 16 15 15 15 11 30 11 11 11 14 11 14 11
A B C sin-1 cos-1 tan-1 D
11 30 14 14 14 20 24 24 11 21 24 20 11 11 11
21 17 21 17 21 17 9 11 19
9 21 17 21 17 21 17 19 19
19 17 19 17 19 17 21 18 21 18


17 12 16 15 15 15 11 30 11 11 11 14 11 14 11
A B C sin-1 cos-1 tan-1 D
11 30 14 14 14 20 24 24 11 21 24 20 11 11 11
21 17 21 17 21 17 9 11 19
9 21 17 21 17 21 17 19 19
19 17 19 17 19 17 21 18 21 18

Before Starting Calculations...



1.5-08
23 9 32 23 + 9 j 3 53 6 47 53 , 6 | ) 45 2 90
–11.00

193.2 28 6.9
193.2 j 1 \ 23 =
p 1 \ 28 =
4 5 2 3
2 C 3 + 1 C 4 C 5 =
2 7 15.00
3 4 2 3 4.00
11 4.00
1 2.00

1 2.00
1500 - 12 A v
660 \ 880 A v
2500 - 15 A v +
2875.00
3500 - 25 A v ,
2625.00
300 500 500
100 160 (%)
300 + 500 A v
46 40 40
100 15 (%)
46 , 40 A v

Functions
q q q 1 →“ R ”
0.89785901200
q q q 2 →“ T ”
W R A x \ 3 T =
2 2 π 4
q q q 2 →“ T ”
W A V R L 2 \ 2 T =
0.78539816300
g \ A x =
0.2500
q q q 1 →“ R ”
36.5384457700
A g 0.741 =
k Hyperbolic/Inverse Hyperbolic
Functions
18.2854553600
4.09462222400
π 3

4.25 A v 2 (R) = 243.5070629 4 . 2 5 r
Antilogarithms
0.08990511100
4.4998096700
22026.4657900
31.622776600
Squares, Cubes, Reciprocals, Factorials, Random Numbers and π
5.28719690900
–1.29002405300

1.98864779500
1023.00
1728.00
1 1 3 4
R 3 a , 4 a T a =
40320.00
0.66400
Example (results differ each time)
9.42477796100
200 \ 7 - 14 =
(Specifies three decimal places.)
400.00000
(Calculation continues using 10 display digits)
200 \ 7 =
28.57100
400.00000
Performing the same calculation using the specified number of decimal places
200 \ 7 =
28.57100
(Internal rounding) A Q
28.57100
Fix · - 14 =

399.99400
F 2 2 1 \ 3 =
3.3–01
56.088003
81.25–03
Key Operation Unit Symbol A k 103 k (kilo) A M 106 M (Mega) A g 109 G (Giga) A t 1012 T (Tera) A m 10–3 m (milli) A N 10–6 µ (micro) A n 10–9 n (nano) A p 10–12 p (pico) A f 10–15 f (femto)
- 14 = · Sci

* For displayed values, the calculator selects the ENG sym- bol that makes the numeric part of the value fall within the range of 1 to 1000. * ENG symbols cannot be used when inputting fractions. * The ENG mode cannot be used in combination with the CMPLX, or BASE-N modes.
9 \ 10 = 900. 9 1 m
In the ENG mode, even standard (non-ENG) calculation results are displayed using ENG symbols.
J 900. 9 1 m
k Coordinate Conversion (Pol(x, y), Rec (r, θ))
x A F 2 P 60 T =
1.73205080800
r A f 1 P L 3 T =
y 0 o

1.04719755100
7 A m 4 =
10 A n 4 =
0 1 Σx2 0 2 Σx 0 k n A M o A A σn A N σn-1
θ 0 o

Enter SD Mode F F 1 A m = (Memory Clear)
55 S 54 S 51 S 55 S 53 S S 54 S 52 S
(Sample Standard Deviation σn1) A N =
1.40788595300
(Population Standard Deviation σn) A A =
1.31695671900
(Arithmetic Mean o) A M =
53.37500
(Number of Data n) 0 k
(Sum of Values Σx) 0 H
(Sum of Squares of Values Σx 2) 0 G
22805.00
P(t) R(t) Q(t)

A D 1 ( P ( ) - 0.28 F = 0.38974
k Regression Calculations (REG Mode)
0 G Σx2 0 H Σx 0 k n 0 h Σy2 0 n Σy 0 o Σxy 0 M Σx3 0 x Σx2y 0 y Σx4 A M o A A xσn
A N xσn-1 A l p A d yσn A c yσn-1 A q Regression coefficient A A w Regression coefficient B A e Regression coefficient C A u Correlation coefficient r A O m A b n
The regression formula for linear regression is: y A Bx.

Perform linear regression to de- termine the regression formula terms and correlation coefficient for the data nearby. Next, use the regression formula to estimate at- mospheric pressure at 18°C and temperature at 1000 hPa.
Pressure 10°C 1003 hPa 15°C 1005 hPa 20°C 1010 hPa 25°C 1011 hPa 30°C 1014 hPa
Enter REG Mode (Linear Regression) q q 2 1 A m = (Memory Clear)
10 P1003 S 15 P1005 S 20 P1010 S 25 P 1011 S 30 P1014 S
(Regression Coefficient A) A q =
997.400
(Regression Coefficient B) A w =
0.5600
(Correlation Coefficient r) A J =
0.98260736800
(Atmospheric Pressure at 18°C) 18 A b
1007.4800
(Temperature at 1000 hPa) 1000 A O
4.64285714300
xi yi 29 1.6 50 23.5 74 38.0 103 46.4 118 48.0
Perform quadratic regression to de- termine the regression formula terms and correlation coefficient for the data nearby. Next, use the regression for- mula to estimate the values for ˆy (es- timated value of y) for xi = 16 and ˆx (estimated value of x) for yi = 20.
Temperature Atmospheric

Enter REG mode (Quadratic regression) F F 2 r 3 A m =
29 P 1.6 S 50 P 23.5 S 74 P 38.0 S103 P 46.4 S 118 P 48.0 S 118. REG
(Regression Coefficient B) A w = 1.495939413
( ˆy when x i = 16) 16 A b - 13.38291067
(ˆx 1 when yi = 20) 20 A O 47.14556728
(ˆx 2 when yi = 20) A O 175.5872105

Enter CMPLX Mode F 2
R 2 + 3 i T +
R 4 + 5 i T = 6.
Real number part A r 8. i
Determine the absolute value.
A A R 3 + 4 i T = 5. CMPLX Determine the argument.
A a R 3 + 4 i T = 53.13010235
Imaginary number part · Imaginary number axis · Real number axis

Input the formula.
p y p u p x K +
3 p x , 12 Y= X 2 + 3 X-12
Store it in memory. C
Input a value for its variable. 7 = 58.
8 = 76.
31 A c CONV
01 is the inches-to-centimeters conversion pair number.
= 78.74 31 i n cm
=

Number Conversion Pair Number Conversion Pair 01 in → cm 21 oz → g 02 cm → in 22 g → oz 03 ft → m 23 lb → kg 04 m → ft 24 kg → lb 05 yd → m 25 atm → Pa 06 m → yd 26 Pa → atm 07 mile → km 27 mmHg → Pa 08 km → mile 28 Pa → mmHg 09 n mile → m 29 hp → kW 10 m → n mile 30 kW → hp 11 acre → m2 31 kgf/cm2→ Pa 12 m2 → acre 32 Pa → kgf/cm2
17 pc → km 37 °F → °C 18 km → pc 38 °C → °F 19 km/h → m/s 39 J → cal 20 m/s → km/h 40 cal → J

28 CONST28
28 is the “speed of light in vacuum” constant number.
K 0. 65 Co 2
65 Co 2 5.841908662 18
Number Constant Name Symbol 01 proton mass mp 02 neutron mass mn 03 electron mass me 04 muon mass mµ 05 Bohr radius a 0 06 Planck's constant h 07 nuclear magneton µ N 08 Bohr magneton µ B 09 Planck's constant, rationalized (h-bar) 10 fine-structure constant α 11 classical electron radius re 12 electron Compton wavelength λ c 13 proton gyromagnetic ratio γ p 14 proton Compton wavelength λ cp 15 neutron Compton wavelength λ cn 16 Rydberg constant R∞ 17 atomic mass unit u 18 proton magnetic moment µ p 19 electron magnetic moment µ e 20 neutron magnetic moment µ n 21 muon magnetic moment µ µ 22 Faraday constant F
=

Number Constant Name Symbol 23 elementary charge e 24 Avogadro constant NA 25 Boltzmann constant k 26 molar volume of ideal gas Vm 27 molar gas constant R 28 speed of light in vacuum C 0 29 first radiation constant C 1 30 second radiation constant C 2 31 Stefan-Boltzmann constant σ 32 permittivity of vacuum ε 0 33 permeability of vacuum µ 0 34 magnetic flux quantum φ 0 35 standard acceleration of gravity g 36 astronomical unit AU 37 parsec pc 38 Celsius temperature t 39 Newtonian constant of gravitation G 40 standard atmosphere atm

Binary 1000000000 x 1111111111 0 x 0111111111 Octal 4000000000 x 7777777777 0 x 3777777777 Decimal –2147483648 x 2147483647 Hexadecimal 80000000 x FFFFFFFF 0 x 7FFFFFFF
101112 + 110102 Binary mode F F 3 b 0. b
101112 + 110102 0. b
= 110001. b
76548 ÷ 1210 Octal mode F F 3 o 0. o
l l l 4 (o) 76548 \
l l l 1 (d)1210 0. o
= 516. o
12016 or 11012 Hexadecimal mode F F 3 h 0. H
12016 l 2 (or)
l l l 3 (b)11012 0. H
= 12d. H

d 2 p x K + 3 p x +
8 P 1 P 5 P 6 T 0.
2.258 = 2.258
12 I 34 I 56 I - 3.45 0.
= 43°24°31.2

k When you have a problem
If calculation results are not what you expect or if an error occurs, perform the following steps. 1. F 1 (COMP mode) 2. F F F 1 (DEG mode) 3. F 3 1 (NORM 1 mode) 4. Check the formula you are working with to confirm it is correct. 5. Enter the correct modes to perform the calculation and try again.
< fx-570W/ fx-100W > If the above steps do not correct your problem, press the P button (see page 35 or 36) on the back of the calculator to reset it. Pressing the P button deletes all data stored in calculator memory. Make sure you always keep written copies of all important data.
< fx-991W/ fx-115W > If the above steps do not correct the problem, press the 5 key. The calculator performs a self-check operation and deletes all data stored in memory if any abnormality is detected. Make sure you always keep written copies of all important data.
k Error Messages The calculator is locked up while an error message is on the display. Press t to clear the error, or press e or r to display the calculation and correct the problem. See “Error Locator” on page 10 for details.

k Order of Operations Calculations are performed in the following order of prec- edence. 1 Coordinate transformation: Pol (x, y), Rec (r, θ) Integrations: ∫dx 2 Type A functions: With these functions, the value is entered and then the function key is pressed. x2, x1, x!, ° ’ ” 3 Powers and roots: xy, x

4 ab/c 5 Abbreviated multiplication format in front of π, memory name, or variable name: 2π, 5A, πA etc. 6 Type B functions: With these functions, the function key is pressed and then the value is entered.
3 , log, In, ex, 10x, sin, cos, tan, sin1, cos1, tan1, sinh, cosh, tanh, sinh1, cosh1, tanh1, () 7 Abbreviated multiplication format in front of Type B functions: 2 3, Alog2 etc. 8 Permutation and combination: nPr, nCr 9 , 0 , * Operations of the same precedence are performed from right to left. exIn 120 → ex{In( 120)} Other operations are performed from left to right. * Operations enclosed in parentheses are performed first.
k Stacks This calculator uses memory areas, called “stacks,” to tem- porarily store values (numeric stack) and commands (com- mand stack) according to their precedence during calcu- lations. The numeric stack has 10 levels and the command stack has 24 levels. A stack error (Stk ERROR) occurs whenever you try to perform a calculation that is so com- plex that the capacity of a stack is exceeded.
,

k Power Supply The type of battery you should use depends on the model number of your calculator.
< fx-991W/ fx-115W > The TWO WAY POWER system actually has two power supplies: a solar cell and a G13 Type (LR44) button bat- tery. Normally, calculators equipped with a solar cell alone can operate only when relatively bright light is present. The TWO WAY POWER system, however, lets you con- tinue to use the calculator as long as there is enough light to read the display.
2 Remove the old battery.
3 Wipe off the sides of new bat- tery with a dry, soft cloth. Load it into the unit with the posi- tive k side facing up (so you can see it).
4 Replace the back cover and secure it in place with the six screws.
5 Press 5 to turn power on. Be sure not to skip this step.
Screw Screw

< fx-570W > This calculator is powered by single G13 Type (LR44) but- ton battery.
Dim figures on the display of the calculator indicate that battery power is low. Continued use of the calculator when the battery is low can result in improper operation. Replace the battery as soon as possible when display figures become dim.
2 Remove the two screws that hold the battery cover in place and then remove the battery cover. 3 Remove the old battery.
4 Wipe off the side of new battery with a dry, soft cloth. Load it into the unit with the positive k side facing up (so you can see it).
5 Replace the battery cover and secure it in place with the two screws.
6 Use a thin, pointed object to press the P button. Be sure not to skip this step.
7 Press L to turn power on.
Screw · P button

< fx-100W > This calculator is powered by single AA-size battery.
Dim figures on the display of the calculator indicate that battery power is low. Continued use of the calculator when the battery is low can result in improper operation. Replace the battery as soon as possible when display figures become dim.
2 Remove the six screws that hold the back cover in place and then remove the back cover. 3 Remove the old battery.
4 Load a new battery into the unit so it’s positive k and negative l sides are fac- ing correctly.
5 Replace the back cover and secure it in place with the six screws.
6 Use a thin, pointed object to press the P button. Be sure not to skip this step.
7 Press L to turn power on.
Screw · Screw · P button

Internal digits: 12 Accuracy: As a rule, accuracy is ±1 at the 10th digit.
sinx DEG 0 x 4.4999999991010
RAD 0 x 785398163.3
GRA 0 x 4.4999999991010
cosx DEG 0 x 4.5000000081010
RAD 0 x 785398164.9
GRA 0 x 5.0000000091010
tanx DEG Same as sinx, except when x= (2n-1)90.
RAD Same as sinx, except when x= (2n-1)π/2.
GRA Same as sinx, except when x= (2n-1)100. sin–1x 0 x 1 cos–1x
tan–1x 0 x 9.9999999991099
sinhx 0 x 230.2585092 coshx
sinh–1x 0 x 4.9999999991099 cosh–1x
tanhx 0 x 9.99999999910-1 tanh–1x
logx/lnx 0 x
10x –9.9999999991099 x 99.99999999 ex –9.9999999991099 x 230.2585092 x 0 x 1 10100
x2 x 1 1050
1/x x 1 10100 ; x G 0
3 x x 1 10100
x! 0 x 69 (x is an integer)
Functions Input Range

nPr 0 n 99, r n (n, r is an integer) 1 {n!/(n–r)!} 9.9999999991099 nCr 0 n 99, r n (n, r is an integer)
Pol(x, y) x, y 9.9999999991049
(x2+y2) 9.9999999991099
Rec(r, ) 0 r 9.9999999991099
a, b, c 110100
°’ ” 0 b, c x110100
Decimal ↔ Sexagesimal Conversions 000000 x 9999990590
x0: –110100ylogx100 xy x0: y0 x0: yn, (n is an integer) However: –110100 ylogx100 y0: x G 0 –1101001/x logy100 x y y0: x0 y0: x2n1, (n G 0; n is an integer) However: –110100 1/x logy100
1 2n+1
Total of integer, numerator, and denominator must be 10 digits or less (including division marks).
x 11050
y 11050
SD n 110100
(REG) xn, yn, o, p A, B, r: n G 0 xn–1, yn–1 : n G 0, 1
* Erros are cumulative with such internal continuous cal- culations as xy, x x, x!, and
3 x, so accuracy may be adversely affected.
Functions Input Range · 1 n

Power Supply:
Solar cell and a single G13 Type button bat- tery (LR44)
Battery Life:
play of flashing cursor. Approximately 2 years when left with power turned off. fx-570W: Approximately 12,000 hours continuous dis-
play of flashing cursor. Approximately 3 years when left with power turned off. fx-115W/ fx-991W:
Approximately 3 years (1 hour use per day).
Dimensions:
3/4(H) 3(W) 67/16(D) fx-115W/ fx-570W/ fx-991W:
10(H) 76(W) 150(D) mm 3/8(H) 3(W) 57/8(D)
Weight:
fx-100W: 114 g (4 oz) including battery fx-115W/ fx-570W/ fx-991W: 85 g (3 oz) including battery

CASIO ELECTRONICS CO., LTD. Unit 6, 1000 North Circular Road, London NW2 7JD, U.K.

CASIO COMPUTER CO., LTD.
6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, Japan
SA9810-C Printed in China
U.S. Pat. 4,410.956
Imprimé en Chine
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.