


CASIO EDUCATIONAL FORUM http://edu.casio.com/forum/



Sample operations in this manual are indicated by a icon. Unless specifically stated, all sample operations assume that the calculator is in its initial default setup. Use the procedure under “Initializing the Calculator” to return the calculator to its initial default setup. For information about the , 1, B, and * marks that are shown in the sample operations, see “Configuring the Calculator Setup”.
Perform the following procedure when you want to initialize the calculator and return the calculation mode and setup to their initial default settings. Note that this operation also clears all data currently in calculator memory. (CLR)(All)(Yes)

Before using the calculator, slide its hard case downwards to remove it, and then affix the hard case to the back of the calculator as shown in the illustration nearby.

Press to turn on the calculator. Press (OFF) to turn off the calculator.
Auto Power Off Your calculator will turn off automatically if you do not perform any operation for about 10 minutes. If this happens, press the key to turn the calculator back on.
Display the CONTRAST screen by performing the following key operation: (SETUP)A(;CONT). Next, use B and C to adjust contrast. After the setting is the way you want, press . Important: If adjusting display contrast does not improve display readability, it probably means that battery power is low. Replace the battery.
Pressing the or # key followed by a second key performs the alternate function of the second key. The alternate function is indicated by the text printed above the key. The following shows what the different colors of the alternate function key text mean.
sin –1 D s


The display of the calculator shows expressions you input, calculation results, and various indicators.



First perform the following key operation to display the setup menu: (SETUP). Next, use A and D and the number keys to configure the settings you want. Underlined (___) settings are initial defaults.
MthIO LineIO Specifies the display format. Natural Display (MthIO) causes fractions, irrational numbers, and other expressions to be displayed as they are written on paper.

MthIO: Selects MathO or LineO. MathO displays input and calculation results using the same format as they are written on paper. LineO displays input the same way as MathO, but calculation results are displayed in linear format.
Linear Display (LineIO) causes fractions and other expressions to be displayed in a single line.

·

Deg Rad Gra Specifies degrees, radians or grads as the angle unit for value input and calculation result display. Note: In this manual, the B symbol next to a sample operation indicates degrees, while the * symbol indicates radians.
Fix Sci Norm Specifies the number of digits for display of a calculation result. Fix: The value you specify (from 0 to 9) controls the number of decimal places for displayed calculation results. Calculation results are rounded off to the specified digit before being displayed. Example: 1 100 ÷ 7 = 14.286 (Fix 3) 14.29 (Fix 2) Sci: The value you specify (from 1 to 10) controls the number of significant digits for displayed calculation results. Calculation results are rounded off to the specified digit before being displayed. Example: 1 1 ÷ 7 = 1.4286 s 10–1 (Sci 5)
1.429 s 10–1 (Sci 4) Norm: Selecting one of the two available settings (Norm 1, Norm 2) determines the range in which results will be displayed in non-exponential format. Outside the specified range, results are displayed using exponential format. Norm 1: 10–2 |x|, |x| > 1010 Norm 2: 10–9 |x|, |x| > 1010 Example: 1 1 ÷ 200 = 5 s 10–3 (Norm 1) 0.005 (Norm 2)
Aab/c A d/c Specifies either mixed fraction (ab/c) or improper fraction (d/c) for display of fractions in calculation results.
ASTAT ON ; OFF Specifies whether or not to display a FREQ (frequency) column in the STAT Mode Stat Editor.
ARdec ON ; OFF Specifies whether or not to display calculation results using recurring decimal form.
ADisp Dot ; Comma Specifies whether to display a dot or a comma for the calculation result decimal point. A dot is always displayed during input. Note: When dot is selected as the decimal point, the separator for multiple results is a comma (,). When comma is selected, the separator is a semicolon (;).
A;CONT Adjusts display contrast. See “Adjusting Display Contrast” for details.
Initializing Calculator Settings Perform the following procedure to initialize the calculator, which returns the calculation mode to COMP and returns all other settings, including setup menu settings, to their initial defaults. (CLR)(Setup)(Yes)

Basic Input Rules Calculations can be input in the same form as they are written. When you press the priority sequence of the input calculation will be evaluated automatically and the result will appear on the display.
4 ssin30 s(30 + 10 s3) = 120 4 Q 30 30 10 3

*1 *2 *3
*1 Input of the closing parenthesis is required for sin, sinh, and other functions that include parentheses. *2 These multiplication symbols (s) can be omitted. A multiplication symbol can be omitted when it occurs immediately before an opening parenthesis, immediately before sin or other function that includes parentheses, immediately before the Ran# (random number) function, or immediately before a variable (A, B, C, D, E, F, M, X, Y), P or e. *3 The closing parenthesis immediately before the operation can be omitted.
Input example omitting *2 and *3 operations in the above example.

Calculation Priority Sequence The priority sequence of input calculations is evaluated in accordance with the rules below. When the priority of two expressions is the same, the calculation is performed from left to right.

Inputting with Natural Display Selecting Natural Display makes it possible to input and display fractions and certain functions (log, x2, x3, x9, x−1, 109, e9, Abs) just as they are written in your textbook.
2 + '2 1 + '2

2 2 CC1 2
Using Values and Expressions as Arguments (Natural Display only) A value or an expression that you have already input can be used as the
argument of a function. After you have input 7
6 , for example, you can make it the argument of , resulting in 7 6 '.
To input 1 + 7
1 7 6

As shown above, the value or expression to the right of the cursor after )(INS) are pressed becomes the argument of the function that is specified next. The range encompassed as the argument is everything up to the first open parenthesis to the right, if there is one, or everything up to the first function to the right (sin(30), log2(4), etc.) This capability can be used with the following functions: , , (), :(), 7(), , , (), .
Overwrite Input Mode (Linear Display only) You can select either insert or overwrite as the input mode, but only while Linear Display is selected. In the overwrite mode, text you input replaces the text at the current cursor location. You can toggle between the insert and overwrite modes by performing the operations: )(INS). The cursor appears as “I” in the insert mode and as “ ” in the overwrite mode. Note: Natural Display always uses the insert mode, so changing display format from Linear Display to Natural Display will automatically switch to the insert mode.
Correcting and Clearing an Expression To delete a single character or function: Move the cursor so it is directly to the right of the character or function you want to delete, and then press ). In the overwrite mode, move the cursor so it is directly under the character or function you want to delete, and then press ). To insert a character or function into a calculation: Use B and C to move the cursor to the location where you want to insert the character or function and then input it. Be sure always to use the insert mode if Linear Display is selected. To clear all of the calculation you are inputting: Press .
Your calculator uses a recurring decimal when you input a value. Calculation results also can be displayed using recurring decimal form whenever applicable.
Inputting a Recurring Decimal When inputting a recurrent decimal, press 7(I
To input 0.33333... (0.3



Displaying a Calculation Result as a Recurring Decimal Value Calculation results that can be displayed as recurring decimal values will be displayed as such when ON is selected for the Rdec setting on the setup menu. Pressing the 5 key will cycle between the available calculation result formats as shown below.
Decimal Value According to Display (Norm, Fix, Sci) Settings
Decimal Value According to Display (Norm, Fix, Sci) Settings
Fraction Recurring Decimal · Or · Recurring Decimal Fraction





0 7(I • ) 3 C 0 7(I
1 7(I • ) 6 C 2 7(I


While Natural Display is selected, each press of 5 will toggle the currently displayed calculation result between its fraction form and decimal form, its form and decimal form, or its P form and decimal form.

(P) 6 1 6 f 0.5235987756
('2 + 2) s '3 = '6 + 2'3 = 5.913591358
2 C 2 3 '6 + 2'3 f 5.913591358
While Linear Display is selected, each press of 5 will toggle the currently displayed calculation result between its decimal form and fraction form.

1 ÷ 5 = 0.2 = 1 5 1
15 0.2 f 1Y5
1 4 5 1Y5 f 0.2

Fraction Calculations Note that the input method for fractions is different, depending upon whether you are using Natural Display or Linear Display.
2 + 1 = 7 3 2 6 2 3 C 1 2 7 6
or 2 A 3 C 1A 2 7 6
1 2 3 1 2 7Y6
1 = 1 2 2 4 − 3 4 () 3 C1A 2 1 2
1 4 3 1 2 1Y2
150 s20% = 30 150 20(%) 30
Calculate what percentage of 880 is 660. (75%) 660880(%) 75
Increase 2500 by 15%. (2875) 2500 2500 15(%) 2875
Discount 3500 by 25%. (2625)
3500 3500 25(%) 2625

Degree, Minute, Second (Sexagesimal) Calculations Performing an addition or subtraction operation between sexagesimal values, or a multiplication or division operation between a sexagesimal value and a decimal value will cause the result to be displayed as a sexagesimal value. You also can convert between sexagesimal and decimal. The following is the input format for a sexagesimal value: {degrees} {minutes} {seconds} .
2°20´30˝ + 39´30˝ = 3°00´00˝
2 20 30 0 39 30 3°0´0˝
Convert 2°15´18˝ to its decimal equivalent.
2 1518 2°15´18˝
(Converts sexagesimal to decimal.) 2.255
(Converts decimal to sexagesimal.) 2°15´18˝
Multi-Statements You can use the colon character (:) to connect two or more expressions and execute them in sequence from left to right when you press .
Using Engineering Notation A simple key operation transforms a displayed value to engineering notation.
Transform the value 1234 to engineering notation, shifting the decimal point to the right.
' 1.234×103
Transform the value 123 to engineering notation, shifting the decimal point to the left. 123 123
'(k) 0.123×103
'(k) 0.000123×106
Calculation History In the COMP Mode, the calculator remembers up to approximately 200 bytes of data for the newest calculation. You can scroll through calculation history contents using D and A.
1 + 1 = 2 1 1 2 2 + 2 = 4 2 2 4
1234 1234 · ' 1234×100

3 + 3 = 6 3 3 6 (Scrolls back.) D 4 (Scrolls back again.) D 2
Replay While a calculation result is on the display, you can press B or C to edit the expression you used for the previous calculation.
4 × 3 + 2.5 = 14.5 1 4 3 2.5 14.5 4 × 3 −7.1 = 4.9 (Continuing) B)))) 7.1 4.9
Answer Memory (Ans) The last calculation result obtained is stored in Ans (answer) memory. Ans memory contents are updated whenever a new calculation result is displayed.

To divide the result of 3 s 4 by 30 1
Variables (A, B, C, D, E, F, X,Y) Your calculator has eight preset variables named A, B, C, D, E, F, X, and Y. You can assign values to variables and also use the variables in calculations.
To assign the result of 3 + 5 to variable A 3 5B(STO)E(A) 8
To multiply the contents of variable A by 10 (Continuing) #E(A) 10 80
To recall the contents of variable A (Continuing) BE(A) 8
To clear the contents of variable A 0B(STO)E(A) 0

Independent Memory (M) You can add calculation results to or subtract results from independent memory. The “M” appears on the display when there is any value other than zero stored in independent memory.

To clear the contents of M 0B(STO)J(M) 0
To add the result of 10 s 5 to M (Continuing) 10 5J 50
To subtract the result of 10 + 5 from M (Continuing) 10 5J(M–) 15
To recall the contents of M (Continuing) BJ(M) 35
Clearing the Contents of All Memories Ans memory, independent memory, and variable contents are retained even if you press , change the calculation mode, or turn off the calculator. Perform the following procedure when you want to clear the contents of all memories. (CLR)(Memory)(Yes)
In the COMP Mode, you can factor a positive integer up to 10 digits into prime factors up to three digits.

When you perform prime factorization on a value that includes a factor that is prime number with more than three digits, the part that cannot be factored will be enclosed in parentheses on the display.

To perform prime factorization on 4104676 (= 22 s 10132)

For actual operations using each function, see the “Examples” section following the list below.
: P is displayed as 3.141592654, but P = 3.14159265358980 is used for internal calculations. e: e is displayed as 2.718281828, but e = 2.71828182845904 is used for internal calculations.
sin, cos, tan, sin−1, cos−1, tan−1: Trigonometric functions. Specify the angle unit before performing calculations. See 1.
sinh, cosh, tanh, sinh−1, cosh−1, tanh−1: Hyperbolic functions. Input a function from the menu that appears when you press E. The angle unit setting does not affect calculations. See 2.
°, r, g: These functions specify the angle unit. ° specifies degrees, r radians, and g grads. Input a function from the menu that appears when you perform the following key operation: (DRG). See 3. , : Exponential functions. Note that the input method is different depending upon whether you are using Natural Display or Linear Display. See 4.
log: Logarithmic function. Use the : key to input logab as log (a, b). Base 10 is the default setting if you do not input anything for a. The key also can be used for input, but only while Natural Display is selected. In this case, you must input a value for the base. See 5.
ln: Natural logarithm to base e. See 6. x2, x3, x9, , , , x−1: Powers, power roots, and reciprocals. Note that the input methods for x9, , , and and are different depending upon are different depending upon whether you are using Natural Display or Linear Display. See 7.
22, input 27, press the B key, and then press 7().
Pol, Rec: Pol converts rectangular coordinates to polar coordinates, while Rec converts polar coordinates to rectangular coordinates. See 8.
Pol(x, y) = (r, Ƨ) Rec(r, Ƨ) = (x, y)

Specify the angle unit before performing calculations. The calculation result for r and Ƨ and for x and y are each assigned respectively to variables X and Y. Calculation result Q is displayed in the range of −180° Q 180°.
Rectangular Polar Coordinates (Rec) Coordinates (Pol)
x!: Factorial function. See 9.
Abs: Absolute value function. Note that the input method is different depending upon whether you are using Natural Display or Linear Display. See 10.
Ran#: Generates a 3-digit pseudo random number that is less than 1. The result is displayed as a fraction when Natural Display is selected. See 11.

RanInt#: For input of the function of the form RanInt#(a, b), which generates a random integer within the range of a to b. See 12. nPr, nCr: Permutation (nPr) and combination (nCr) functions. See 13.
Rnd:Theargumentofthisfunctionismadeadecimalvalueandthenrounded in accordance with the current number of display digits setting (Norm, Fix, or Sci). With Norm 1 or Norm 2, the argument is rounded off to 10 digits. With Fix and Sci, the argument is rounded off to the specified digit. When Fix 3 is the display digits setting, for example, the result of 10 ÷ 3 is displayed as 3.333, while the calculator maintains a value of 3.33333333333333 (15 digits) internally for calculation. In the case of Rnd(10÷3) = 3.333 (with Fix 3), both the displayed value and the calculator’s internal value become 3.333. Because of this a series of calculations will produce different results depending on whether Rnd is used (Rnd(10÷3) s 3 = 9.999) or not used (10 ÷ 3 s3 = 10.000). See 14.
sin 30°= 0.5 1B Q 30 0.5
sin−10.5 = 30° 1B Q(sin−1)0.5 30
sinh 1 = 1.175201194 E@(sinh)1 1.175201194
cosh–1 1 = 0 ED(cosh−1)1 0
P/2 radians = 90°, 50 grads = 45° B
(P) 2 (DRG)A(r) 90 50(DRG)B(g) 45
To calculate e5s2 to three significant digits (Sci 3)
(SETUP)(Sci)
7()5C 2 2.97×102
1 7()5 2 2.97×102
log101000 = log 1000 = 3 :1000 3
To calculate ln 90 (= loge 90) to three significant digits (Sci 3)
(SETUP)(Sci) 790 4.50×100
1.2 s103 = 1200 1.2 10 3 1200
(1+1)2+2 = 16 1 1 2 2 16 (52)3 = 15625 5V 15625
32 5 = 2 () 5C 32 2 1 5() 32 2

To calculate '2 × 3 (= 3'2 = 4.242640687...) to three decimal places (Fix 3) (SETUP)(Fix) 2 C 3 3'2 4.243 1 2 3 4.243
To convert rectangular coordinates ('2 , '2 ) to polar coordinates B (Pol) 2 C(,) 2 C r=2,Ƨ=45 1 (Pol) 2 (,) 2 r= 2 Ƨ= 45 To convert polar coordinates ('2 , 45°) to rectangular coordinates B (Rec) 2 C(,) 45 X=1,Y=1

(5 + 3) ! = 40320 5 3 (x!) 40320
|2 – 7| s 2 = 10 2 7C 2 10 1 2 7 2 10
To obtain three random three-digit integers
1000 (Ran#) 459 48 117
(Results shown here are for illustrative purposes only. Actual results will differ.)
To generate random integers in the range of 1 to 6
# (RanInt)1(,) 6 2 6 1
(Results shown here are for illustrative purposes only. Actual results will differ.)
To determine the number of permutations and combinations possible when selecting four people from a group of 10
Permutations: 10 (nPr) 4 5040 Combinations: 10(nCr) 4 210
To perform the following calculations when Fix 3 is selected for the number of display digits: 10 ÷ 3 s 3 and Rnd(10 ÷ 3) s 3 1
(SETUP)(Fix) 10 3 3 10.000 (Rnd)10 3 3 9.999

To start a statistical calculation, perform the key operation (STAT) to enter the STAT Mode and then use the screen that appears to select the type of calculation you want to perform.
To select this type of statistical calculation:
(Regression formula shown in parentheses) Press this key:
Single-variable (X) (1-VAR)
Paired-variable (X, Y), linear regression (y = A + Bx) (A+BX)
Paired-variable (X, Y), quadratic regression
(y = A + Bx + Cx2) (_+CX2)
Paired-variable (X, Y), logarithmic regression
(y = A + Blnx) (ln X)
Paired-variable (X, Y), e exponential regression
(y = AeBx) (e^X)
Paired-variable (X, Y), ab exponential regression
(y = ABx) (A•B^X)
Paired-variable (X, Y), power regression (y = AxB) (A•X^B)
Paired-variable (X, Y), inverse regression
(y = A + B/x) (1/X)
Pressing any of the above keys ( to ) displays the Stat Editor. Note: When you want to change the calculation type after entering the STAT Mode, perform the key operation (STAT)(Type) to display the calculation type selection screen.
Inputting Data Use the Stat Editor to input data. Perform the following key operation to display the Stat Editor: (STAT)(Data). The Stat Editor provides 80 rows for data input when there is an X column only, 40 rows when there are X and FREQ columns or X and Y columns, or 26 rows when there are X, Y, and FREQ columns. Note: Use the FREQ (frequency) column to input the quantity (frequency) of identical data items. Display of the FREQ column can be turned on (displayed) or off (not displayed) using the Stat Format setting on the setup menu.
To select linear regression and input the following data: (170, 66), (173, 68), (179, 75)
STAT

STAT
STAT

STAT
STAT

66 6875

Obtaining Statistical Values from Input Data To obtain statistical values, press while in the Stat Editor and then recall the statistical variable (Sx, 3x2, etc.) you want. Supported statistical variables and the keys you should press to recall them are shown below. For single-variable statistical calculations, the variables marked with an asterisk (*) are available.
To input the single-variable data x = {1, 2, 2, 3, 3, 3, 4, 4, 5}, using the FREQ column to specify the number of repeats for each items ({xn; freqn} = {1;1, 2;2, 3;3, 4;2, 5;1}), and calculate the mean and population standard deviation.

(STAT)(1-VAR) 1 2 3 4 5AC 1 2 3 2

(STAT)(Var)(M)
(STAT)(Var)(Sx)
To calculate the linear regression and logarithmic regression correlation coefficients for the following paired-variable data and determine the regression formula for the strongest correlation: (x, y)
= (20, 3150), (110, 7310), (200, 8800), (290, 9310). Specify Fix 3 (three decimal places) for results.
(SETUP)A(STAT)(OFF) (SETUP)(Fix)
(STAT)(A+BX) 20110 200 290AC 3150731088009310
STAT FIX

(STAT)(Reg)(r)
(STAT)(Type)(In X) (STAT)(Reg)(r)
(STAT)(Reg)(A)
(STAT)(Reg)(B)
Logarithmic Regression Correlation Coefficient: 0.998 Logarithmic Regression Formula: y = –3857.984 + 2357.532lnx
Calculating Estimated Values Based on the regression formula obtained by paired-variable statistical calculation, the estimated value of y can be calculated for a given x-value. The corresponding x-value (two values, x1 and x2, in the case of quadratic regression) also can be calculated for a value of y in the regression formula.
To determine the estimate value for y when x = 160 in the regression formula produced by logarithmic regression of the data in 3. Specify Fix 3 for the result. (Perform the following operation after completing the operations in 3.) 160(STAT)(Reg)(L)
·

Start? Input the lower limit of X (Default = 1).
End? Input the upper limit of X (Default = 5). Note: Make sure that the End value is always greater than the Start value.
Step? Input the increment step (Default = 1). Note: The Step specifies by how much the Start value should be sequentially incremented as the number table is generated. If you specify Start = 1 and Step = 1, X sequentially will be assigned the values 1, 2, 3, 4, and so on to generate the number table until the End value is reached.
1 for the range –1 x 1, incremented in steps of 0.5
To generate a number table for the function f(x) = x2 + 2


110.5

VERIFY is a function you can use to verify whether an input equality or inequality is true (indicated by TRUE) or false (indicated by FALSE). The following shows the general procedure for using VERIFY.
To verify whether 4'9 = 12 is true 1. Press (VERIF) to enter the VERIFY Mode.

49C(VERIFY)(=)12 • You can select the equality symbol or inequality symbol from the menu that appears when you press (VERIFY).


2 , cos (8 9))

To verify log2 log3 log4 (VERIF) :2(VERIFY)( ) :3(VERIFY)( ) :4

(VERIF) 0(VERIFY)( ) 89C 89C7

To verify 52 = 25 = 625 (VERIF) 57(VERIFY)(=) 25(VERIFY)(=) 625
The calculation range, number of digits used for internal calculation, and calculation precision depend on the type of calculation you are performing.

Calculation Range p1 s 10–99 to p9.999999999 s 1099 or 0
Precision In general, p1 at the 10th digit for a single calculation. Precision for exponential display is p1 at the least significant digit. Errors are cumulative in the case of consecutive calculations.

DEG 0 \x\ 9 s109
GRA 0 \x\ 1 s1010

DEG 0 \x\ 9 s109
RAD 0 \x\ 157079632.7
GRA 0 \x\ 1 s1010
DEG Same as sinx, except when \x\ = (2n–1) s90.
RAD Same as sinx, except when \x\ = (2n–1) sP/2.
GRA Same as sinx, except when \x\ = (2n–1) s100.
0 \x\ 1 cos–1x
tan–1x 0 \x\ 9.999999999 s1099
sinhx 0 \x\ 230.2585092 coshx
sinh–1x 0 \x\ 4.999999999 s1099
cosh–1x 1 x 4.999999999 s1099
tanhx 0 \x\ 9.999999999 s1099
tanh–1x 0 \x\ 9.999999999 s10–1
logx/lnx 0 x 9.999999999 s1099
10x –9.999999999 s1099 x 99.99999999
ex –9.999999999 s1099 x 230.2585092
'x 0 x 1 s10100
x2 \x\ 1 s1050
x –1 \x\ 1 s10100 ; x & 0
3x \x\ 1 s10100
x! 0 x 69 (x is an integer)
nPr 0 n 1 s1010, 0 r n (n, r are integers) 1 {n!/(n–r)!} 1 s10100
nCr 0 n 1 s1010, 0 r n (n, r are integers) 1 n!/r! 1 s10100 or 1 n!/(n–r)! 1 s10100
\x\, \y\ 9.999999999 s1099
Pol(x, y)
x2+y2 9.999999999 s1099
0 r 9.999999999 s1099
Rec(r, Ƨ)
\a\, b, c 1 s10100; 0 b, c The display seconds value is subject to an error of 21 at the second decimal place.
\x\ 1 s10100
Decimal j Sexagesimal Conversions 0°00˝ \x\ 9999999°5959˝
x0: –1 s10100 ylogx 100 x= 0: y 0 x 0: y = n, m 2n+1 (m, n are integers)

y0: x & 0, –1 s10100 1/x logy 100 y= 0: x 0 y 0: x = 2n+1, 2n+1
m (m & 0; m, n are integers)
Total of integer, numerator, and denominator must be 10 digits or less (including division marks).
a b/c
RanInt#(a, b) a b; \a\, \b\ 1 s1010; b – a 1 s1010
The calculator will display an error message whenever an error occurs for any reason during a calculation. There are two ways to exit an error message display: Pressing B or C to display the location of the error, or pressing to clear the message and calculation.
Displaying the Location of an Error While an error message is displayed, press B or C to return to the calculation screen. The cursor will be positioned at the location where the error occurred, ready for input. Make the necessary corrections to the calculation and execute it again.
When you input 14 ÷ 0 s 2 = by mistake instead of 14 ÷ 10 s 2 =

140 2
C (or B)

Clearing the Error Message While an error message is displayed, press to return to the calculation screen. Note that this also clears the calculation that contained the error.

Syntax ERROR Cause: There is a problem with the format of the calculation you are performing. Action: Make necessary corrections.
Insufficient MEM Error Cause: The configuration of TABLE Mode parameters caused more than 30 X-values to be generated for a table. Action: Narrow the table calculation range by changing the Start, End, and Step values, and try again.
Argument ERROR Cause: A non-integer argument was input for the random number function (RanInt#). Action: Input only integers for the argument.
Before Assuming Malfunction of the Calculator...
Perform the following steps whenever an error occurs during a calculation or when calculation results are not what you expected. If one step does not correct the problem, move on to the next step. Note that you should make separate copies of important data before performing these steps. 1. Check the calculation expression to make sure that it does not contain any errors. 2. Make sure that you are using the correct mode for the type of calculation you are trying to perform. 3. If the above steps do not correct your problem, press the key. This will cause the calculator to perform a routine that checks whether calculation functions are operating correctly. If the calculator discovers any abnormality, it automatically initializes the calculation mode and clears memory contents. For details about initialized settings, see “Configuring the Calculator Setup”. 4. Initialize all modes and settings by performing the following operation: (CLR)(Setup)(Yes).

A low battery is indicated by a dim display, even if contrast is adjusted, or by failure of figures to appear on the display immediately after you turn on the calculator. If this happens, replace the battery with a new one. Important: Removing the battery will cause all of the calculator’s memory contents to be deleted. 1. Press (OFF) to turn off the calculator. 2. Remove the cover as shown in the illustration and replace the battery, taking care that its plus (+) and minus (–) ends are facing correctly. 3. Replace the cover. 4. Initialize the calculator: (CLR)(All)(Yes) • Do not skip the above step!
Power Requirements:
fx-83GT PLUS: AAA-size battery R03 (UM-4) s 1 fx-85GT PLUS: Built-in solar cell; button battery LR44 (GPA76) s 1 Approximate Battery Life:
fx-83GT PLUS: 17,000 hours (continuous display of flashing cursor) fx-85GT PLUS: 3 years (based on one hour of operation per day) Power Consumption: 0.0002 W (fx-83GT PLUS) Operating Temperature: 0°C to 40°C (32°F to 104°F) Dimensions:
fx-83GT PLUS: 13.8 (H) s80 (W) s162 (D) mm 1/2 (H) s31/8 (W) s63/8 (D) fx-85GT PLUS: 11.1 (H) s80 (W) s162 (D) mm 3/8 (H) s31/8 (W) s63/8 (D) Approximate Weight:
fx-83GT PLUS: 100 g (3.5 oz) including the battery fx-85GT PLUS: 95 g (3.4 oz) including the battery
I How can I perform input and display results the same way I did on a
model that does not have Natural Textbook Display? Perform the following key operation: (SETUP)(LineIO). See “Configuring the Calculator Setup” on page E-5 for more information. I How can I change a fraction form result to decimal form? How can I change a fraction form result produced by a division operation to decimal form? See “Toggling Calculation Results” on page E-13 for the procedure.

I What is the difference between Ans memory, independent memory,
and variable memory? Each of these types of memory acts like “containers” for temporary storage of a single value. Ans Memory: Stores the result of the last calculation performed. Use this memory to carry the result of one calculation on to the next. Independent Memory: Use this memory to totalize the results of multiple calculations. Variables: This memory is helpful when you need to uses the same value multiple times in one or more calculations. I What is the key operation to take me from the STAT Mode or TABLE
Mode to a mode where I can perform arithmetic calculations? Press (COMP). I How can I return the calculator to its initial default settings? Perform the following operation: (CLR)(Setup)(Yes) I When I execute a function calculation, why do I get a calculation result
that is completely different from older CASIO calculator models? With a Natural Textbook Display model, the argument of a function that uses parentheses must be followed by a closing parenthesis. Failing to press after the argument to close the parentheses may cause unwanted values or expressions to be included as part of the argument.
Example: (sin 30) + 15 B Older (S-VPAM) Model: Q30 15 15.5 Natural Textbook Display Model: 1 Q30 15 15.5 Failure to press here as shown below will result in calculation of sin 45. Q30 15 0.7071067812
This mark applies in EU countries only.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.