
Perform the following procedure when you want to initialize the calculator and return the calculation mode and setup to their initial default settings. Note that this operation also clears all data currently in calculator memory. fx-82MS/85MS/300MS/350MS: p!,(CLR)3(All)= fx-82SX PLUS/220 PLUS: pr3(All)=
Sample operations in this manual are indicated by a icon. Unless specifically stated, all sample operations assume that the calculator is in its initial default setup. Use the procedure under “3. Initializing the Calculator” to return the calculator to its initial default setup.
RJA521989-001V01 SA0912-A Printed in China
CASIO Worldwide Education Website http://edu.casio.com
User’s Guide
fx-82MS fx-82SX PLUS fx-85MS fx-220 PLUS fx-300MS fx-350MS
d 1ab/c 2 d/c Specifies either mixed fraction (ab/c) or improper fraction (d/c) for display of fractions in calculation results. 1Dot 2 Comma Specifies whether to display a dot or a comma for the calculation result decimal point. A dot is always displayed during input.
1Fix 2Sci 3Norm Specifies the number of digits for display of a calculation result. Fix: The value you specify (from 0 to 9) controls the number of decimal places for displayed calculation results. Calculation results are rounded off to the specified digit before being displayed. Example: 100 ÷ 7 = 14.286 (Fix 3) Sci: The value you specify (from 1 to 10) controls the number of significant digits for displayed calculation results. Calculation results are rounded off to the specified digit before being displayed. Example: 1 ÷ 7 = 1.4286 × 10 –1 (Sci 5) Norm: Selecting one of the two available settings ( Norm 1 , Norm 2) determines the range in which results will be displayed in non- exponential format. Outside the specified range, results are displayed using exponential format. Norm 1: 10 –2 | x |, | x | 10 10 Norm 2: 10 –9 | x |, | x | 10 10 Example: 1 ÷ 200 = 5 × 10–3 (Norm 1); 0.005 (Norm 2)
Pressing the , key more than once displays additional setup screens. Underlined ( ___ ) settings are initial defaults. 1Deg 2Rad 3Gra Specifies degrees, radians or grads as the angle unit for value input and calculation result display. Note: In this manual, the v symbol next to a sample operation indicates degrees.
Before using the calculator, slide its hard case downwards to remove it, and then affix the hard case to the back of the calculator as shown in the illustration nearby.
Regression calculations (fx-82MS/85MS/ 300MS/350MS only) N3(REG)
Standard deviation N2(SD)
General calculations N1(COMP)
When you want to perform this type of operation:
7. Turning Power On and Off
6. Removing the Hard Case
Perform this key operation:
What is the percentage change when a value is increased from 40 to 46? (15%) 46 -40 !=(%) 15. Degree, Minute, Second (Sexagesimal) Calculations The following is the input format for a sexagesimal value: {degrees} $ {minutes} $ {seconds} $.
If 300 grams are added to a test sample originally weighing 500 grams, what is the percentage increase in weight? (160%) 300 +500 !=(%) 160.
Discount 3500 by 25%. (2625) 3500 * 25 1=(%) - 2625.
Increase 2500 by 15%. (2875) 2500 * 15 1=(%) + 2875.
Calculate what percentage of 880 is 660. (75%) 660 / 880 1=(%) 75.
150 × 20% = 30 150 * 20 1=(%) 30.
2 + 1 = 1 3 2 6 1 2 $ 3 + 1 $ 2 = 1 {1 {6.
Correcting and Clearing an Expression To delete a single character or function: 1234_ → ddD → 12 4 To insert a character or function into a calculation: 123_ → d!D(INS) e → 1243 • The cursor changes from “_” to “ t”. To clear all of the calculation you are inputting: Press A.
Initializing Calculator Settings Perform the following procedure to initialize the calculator, which returns the calculation mode to COMP and returns all other settings, including setup menu settings, to their initial defaults. fx-82MS/85MS/300MS/350MS: p1,(CLR)c(Mode)= fx-82SX PLUS/220 PLUS: prc(Mode)=
10th Addition, subtraction (+, –)
9th Multiplication, division ( × , ÷)
8th Permutation ( n P r ), combination ( n C r )
7th Implied multiplication of Type B functions: 2 '3, Alog2, etc.
5th Implied multiplication of π , e (natural logarithm base), memory name, or variable name: 2 π , 3 e , 5A, π A, etc.
Type A functions: With these functions, the value is entered and then the function key is pressed. ( x 3 , x 2 , x −1 , x !, ° ’ ”, m, m1 , m2 , n, °, r , g ) 3rd Powers and roots: ^( x y ), x '
1st Function with parentheses: Pol( x , y ), Rec( r , ), RanInt#( a , b )* (*fx-82SX PLUS/220 PLUS only)
Type B functions: With these functions, the function key is pressed and then the value is entered. ( ', 3 ', log, ln, e x , 10 x , sin, cos, tan, sin −1 , cos −1 , tan −1 , sinh, cosh, tanh, sinh −1 , cosh −1 , tanh −1 , (−))
To clear the contents of M fx-82MS/85MS/300MS/350MS: 0 1t(STO)l(M) 0. fx-82SX PLUS/220 PLUS: 0 1n(Min) 0.
To clear the contents of variable A 0 1t(STO) y(A) 0. Independent Memory (M) You can add calculation results to or subtract results from independent memory. The “M” appears on the display when there is any value other than zero stored in independent memory.
To recall the contents of variable A (Continuing) ty(A) 8.
To multiply the contents of variable A by 10 (Continuing) Sy(A) * 10 = 80.
To assign the result of 3 + 5 to variable A 3 + 5 1t(STO) y(A) 8.
123 + 456 = 579 123 + 456 = 579. 789 – 579 = 210 (Continuing) 789 -G= 210. Variables (A, B, C, D, E, F, X, Y) (fx-82MS/85MS/300MS/350MS only) Your calculator has eight preset variables named A, B, C, D, E, F, X, and Y.
To divide the result of 3 × 4 by 30 3 * 4 = 12. (Continuing) / 30 =
4 × 3 + 2.5 = 14.5 4 * 3 + 2.5 = 14.5 4 × 3 − 7.1 = 4.9 (Continuing) dYYYY- 7.1 = 4.9 Answer Memory (Ans) The last calculation result obtained is stored in Ans (answer) memory. Ans memory contents are updated whenever a new calculation result is displayed.
Replay (Not included on the fx-82SX PLUS) While a calculation result is on the display, you can press d or e to edit the expression you used for the previous calculation.
1 + 1 = 2 1 + 1 = 2. 2 + 2 = 4 2 + 2 = 4. 3 + 3 = 6 3 + 3 = 6. (Scrolls back.) f 4. (Scrolls back again.) f 2. Note: Calculation history data is all cleared whenever you press O, when you change to a different calculation mode, or whenever you initialize modes and settings.
Calculation History (Not included on the fx-82SX PLUS) In the COMP Mode, the calculator remembers up to approximately 150 bytes of data for the newest calculation. You can scroll through calculation history contents using f and c.
Transform the value 1234 to engineering notation, shifting the decimal point to the right. 1234 = 1234. W 1.234×10 3
Using Engineering Notation A simple key operation transforms a displayed value to engineering notation.
3 + 3 : 3 × 3 3 + 3 Sr(:) 3 * 3 = 6. Disp = 9.
Multi-Statements (fx-82MS/85MS/300MS/350MS only) You can use the colon character (:) to connect two or more expressions and execute them in sequence from left to right when you press =.
Convert 2°15´18˝ to its decimal equivalent. 2 $ 15 $ 18 $= 2°15°18. (Converts sexagesimal to decimal.) $ 2.255 (Converts decimal to sexagesimal.) !$(←) 2°15°18.
2°20´30˝ + 39´30˝ = 3°00´00˝ 2 $ 20 $ 30 $+ 0 $ 39 $ 30 $= 3°0°0.
1.2 × 10 3 = 1200 1.2 * 10 M 3 = 1200. (5 2 ) 3 = 15625 ( 5 x)W= 15625.
To calculate ln 90 (= log e 90) to three significant digits (Sci 3) N 2(Sci) 3 i 90 = 4.50×10 0
log 1000 = 3 l 1000 = 3.
To calculate e 5 × 2 to three significant digits (Sci 3) N 2(Sci) 3 1i( e x ) 5 * 2 = 2.97×10 2
π /2 radians = 90°, 50 grads = 45° v (1E(π)/ 2 )1G(DRG')c(R)= 90. 50 1G(DRG ') d(G) = 45.
sinh 1 = 1.175201194 ws(sinh) 1 = 1.175201194 cosh –1 1 = 0 w1c(cosh −1 ) 1 = 0.
sin 30°= 0.5 v s 30 = 0.5 sin −1 0.5 = 30° v 1s(sin −1 ) 0.5 = 30.
Rnd : The argument of this function is made a decimal value and then rounded in accordance with the current number of display digits setting (Norm, Fix, or Sci). With Norm 1 or Norm 2, the argument is rounded off to 10 digits. See 13.
RanInt# (fx-82SX PLUS/220 PLUS only) : For input of the function of the form RanInt#( a , b ), which generates a random integer within the range of a to b . See 11. n P r , n C r : Permutation ( n P r ) and combination ( n C r ) functions. See
Ran# : Generates a 3-digit pseudo random number that is less than 1. See 10.
Specify the angle unit before performing calculations. Calculation result θ is displayed in the range of −180° θ 180°. x ! : Factorial function. See 9.
Rectangular Polar Coordinates (Rec) Coordinates (Pol)
Pol( x , y ) = ( r , ) Rec( r , ) = ( x , y )
Pol, Rec : Pol converts rectangular coordinates to polar coordinates, while Rec converts polar coordinates to rectangular coordinates. See 8.
ln : Natural logarithm to base e . See 6. x 2 , x 3 , ^( x y ), ', 3 ', x ', x −1 : Powers, power roots, and reciprocals. See 7.
log : Logarithmic function. See 5.
10 x , e x : Exponential functions. See 4.
°, r , g : These functions specify the angle unit. ° specifies degrees, r radians, and g grads. Input a function from the menu that appears when you perform the following key operation: 1G(DRG '). See 3.
sinh, cosh, tanh, sinh −1 , cosh −1 , tanh −1 : Hyperbolic functions. The angle unit setting does not affect calculations. See 2.
sin, cos, tan, sin −1 , cos −1 , tan −1 : Trigonometric functions. Specify the angle unit before performing calculations. See 1.
To recall the contents of M fx-82MS/85MS/300MS/350MS: (Continuing) tl(M) 35. fx-82SX PLUS/220 PLUS: (Continuing) n 35. Note: Variable M is used for independent memory. Clearing the Contents of All Memories Independent memory and variable contents are retained even if you press A, change the calculation mode, or turn off the calculator. Perform the following procedure when you want to clear the contents of all memories. fx-82MS/85MS/300MS/350MS: p!,(CLR)1(Mcl)= fx-82SX PLUS/220 PLUS: pr1(Mcl)=
To subtract the result of 10 + 5 from M (Continuing) 10 + 5 1l(M–) 15.
To add the result of 10 × 5 to M (Continuing) 10 * 5 l 50.

Paired-variable (X, Y), quadratic regression ( y = A + Bx + Cx2) ,3(REG)e3(Quad)
Paired-variable (X, Y), inverse regression ( y = A + B/x) ,3(REG)e2(Inv)
Paired-variable (X, Y), power regression ( y = AxB) ,3(REG)e1(Pwr)
Paired-variable (X, Y), e exponential regression ( y = AeB x ) ,3(REG)3(Exp)
Paired-variable (X, Y), logarithmic regression ( y = A + Blnx) ,3(REG)2(Log)
Paired-variable (X, Y), linear regression ( y = A + Bx) ,3(REG)1(Lin)
Single-variable (X) ,2(SD)
To select this type of statistical calculation: (Regression formula shown in parentheses)
To perform the following calculations when Fix 3 is selected for the number of display digits: 10 ÷ 3 × 3 and Rnd(10 ÷ 3) × 3 N 1(Fix) 3 10 / 3 * 3 = 10.000 10 / 3 =10(Rnd) * 3 = 9.999
To determine the number of permutations and combinations possible when selecting four people from a group of 10 Permutations: 10 1{( n P r ) 4 = 5040. Combinations: 10 {4 = 210.
To generate random integers in the range of 1 to 6 (fx-82SX PLUS/220 PLUS only) 12(RanInt) 1 1((,) 6 )= 2. = 6. (Actual results will differ.)
To obtain two random three-digit integers 1000 1.(Ran#) = 459. = 48. (Actual results will differ.)
(5 + 3) ! = 40320 ( 5 + 3 )1E( x !) = 40320.
32 5 = 2 5 1M( x ') 32 = 2. To calculate '2 × 3(= 3 '2 = 4.242640687...) to three decimal places (Fix 3) N 1(Fix) 3 1 2 * 3 = 4.243
Perform this key operation:
2 fx-82MS/85MS/300MS/350MS: To calculate the linear regression and logarithmic regression correlation coefficients ( r ) for the following paired-variable data and determine the regression formula for the strongest correlation: ( x , y ) = (20, 3150), (110, 7310), (200, 8800), (290, 9310). Specify Fix 3 (three decimal places) for results. ,3(REG) 1(Lin) , 1(Fix) 3 20 , 3150 7 110 , 7310 7 200 , 8800 7 290 , 9310 7 !2(S-VAR) ee3(r) = 0.923 ,3(REG) 2(Log) 20 , 3150 7 110 , 7310 7 200 , 8800 7 290 , 9310 7 !2(S-VAR) ee3(r) = 0.998 !2(S-VAR) ee1(A) = −3857.984 !2(S-VAR) ee2(B) = 2357.532 Logarithmic Regression Formula: y = –3857.984 + 2357.532lnx
To calculate the mean ( o) and population standard deviation ( σ x ) for the following data: 55, 54, 51, 55, 53, 53, 54, 52 ,c(SD) 55 7 54 7 51 7 55 7 53 77 54 7 52 7 fx-82SX PLUS/220 PLUS: !h( o) = 53.375 !i( σ x ) = 1.316956719 fx-82MS/85MS/300MS/350MS: !c(S-VAR) b( o) 53.375 !c(S-VAR) c( σ x ) 1.316956719
To determine the estimate value for y when x = 160 in the regression formula produced by logarithmic regression of the data in 2. Specify Fix 3 for the result. (Perform the following operation after completing the operations in 2.) 160 12(S-VAR) eee2( n) = 8106.898 Important: Regression coefficient, correlation coefficient, and estimated value calculations can take considerable time when there are a large number of data items.
Calculating Estimated Values Based on the regression formula obtained by paired-variable statistical calculation, the estimated value of y can be calculated for a given x-value. The corresponding x-value (two values, x1 and x2, in the case of quadratic regression) also can be calculated for a value of y in the regression formula.
RanInt#(a, b) a b; |a|, |b| 1 × 1010; b – a 1 × 1010 (a, b are integers)
Rec(r, ) 0 r 9.999999999 × 1099
Pol(x, y) |x|, |y| 9.999999999 × 1099 x2 + y2 9.999999999 × 1099
a b/c
logx/lnx 0 x 9.999999999 × 1099
tanh–1x 0 |x| 9.999999999 × 10–1
tanhx 0 |x| 9.999999999 × 1099
cosh–1x 1 x 4.999999999 × 1099
sinh–1x 0 |x| 4.999999999 × 1099
nCr 0 n 1 × 1010, 0 r n (n, r are integers) 1 n!/r! 1 × 10100 or 1 n!/(n–r)! 1 × 10100
nPr 0 n 1 × 1010, 0 r n (n, r are integers) 1 {n!/(n–r)!} 1 × 10100
x! 0 x 69 (x is an integer)
3'x |x| 1 × 10100
x –1 |x| 1 × 10100; x G 0
x2 |x| 1 × 1050
'x 0 x 1 × 10100
ex –9.999999999 × 1099 x 230.2585092
10x –9.999999999 × 1099 x 99.99999999
Total of integer, numerator, and denominator must be 10 digits or less (including division marks).
y 0: x G 0, –1 × 10100 1/x logy 100 y = 0: x 0 y 0: x = 2n+1, 1 n (n G 0; n is an integer)
x 0: –1 × 10100 ylogx 100 x = 0: y 0 x 0: y = n, 1 2n+1 (n is an integer)
Decimal ↔ Sexagesimal Conversions 0°0´0˝ |x| 9999999°59´
|x| 1 × 10100
|a|, b, c 1 × 10100; 0 b, c The display seconds value is subject to an error of ±1 at the second decimal place.
fx-82MS/82SX PLUS/ 220 PLUS fx-350MS fx-85MS/300MS
Important: Removing the battery will cause all of the calculator’s memory contents to be deleted. 1. Press 1A(OFF) to turn off the calculator. • To ensure that you do not accidentally turn on power while replacing the battery, slide the hard case onto the front of the calculator (fx-350MS). 2. Remove the cover as shown in the illustration and replace the battery, taking care that its plus (+) and minus (–) ends are facing correctly. Screw Screw
Perform the following steps whenever an error occurs during a calculation or when calculation results are not what you expected. Note that you should make separate copies of important data before performing these steps. 1. Check the calculation expression to make sure that it does not contain any errors. 2. Make sure that you are using the correct mode for the type of calculation you are trying to perform. 3. If the above steps do not correct your problem, press the O key. 4. Initialize all modes and settings. See “Initializing Calculator Settings”.
fx-82SX PLUS fx-220 PLUS
fx-82MS 18.6 × 85 × 156 mm 3 / 4 × 3 3 / 8 × 6 1 / 8
Power Requirements: fx-82MS/82SX PLUS/220 PLUS: AA-size battery R6P (SUM-3) × 1 fx-350MS: Button battery LR44 (GPA76) × 1 fx-85MS/300MS: Built-in solar cell; button battery LR44 (GPA76) × 1 Approximate Battery Life: fx-82MS/82SX PLUS/220 PLUS: 17,000 hours (continuous display of flashing cursor) fx-350MS: 9,000 hours (continuous operation) fx-85MS/300MS: 3 years (based on one hour of operation per day) Power Consumption: 0.0001 W (fx-82MS/82SX PLUS/220 PLUS/350MS) Operating Temperature: 0°C to 40°C (32°F to 104°F) Dimensions (H × W × D)/ Approximate Weight (including the battery)
This mark applies in EU countries only.
12.2 × 85 × 155 mm 1 / 2 × 3 3 / 8 × 6 1 / 8
19.5 × 78 × 155 mm 3 / 4 × 3 1 / 8 × 6 1 / 8
100 g (3.5 oz)
115 g (4.1 oz)
115 g (4.1 oz)
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.