EN
Advantech logo
Official user manual

Advantech USB-4761

38 pages·748 KB·Network Card·PDF·ENDEFRITNLJA
Advantech USB-4761
Table of Contents 57 sections Contents · Chapter 1 Introduction · 1.1 Features · 1.1.1 Robust Protection · … ShowHide
Contentsp.5Chapter 1 Introductionp.81.1 Featuresp.81.1.1 Robust Protectionp.91.1.2 Wide Input Rangep.91.1.3 Reset Protection for Industrial Applicationsp.91.1.4 Plug & Play Functionp.91.2 Applicationsp.101.3 Installation Guidep.10Figure 1.1: Installation Flow Chartp.111.4 Software Overviewp.121.4.1 Programming Choices for DA&C Module:p.121.4.2 Device Driversp.121.5 Device Driver Programmingp.131.5.1 Programming Toolsp.131.5.2 Programming with Device Drivers Function Libraryp.141.5.3 Troubleshooting Device Drivers Errorp.14Chapter 2 Installationp.162.1 Unpackingp.162.2 Driver Installationp.17Figure 2.1: Advantech Automation Software Setupp.172.3 Hardware Installationp.18Figure 2.2: Device Name on the Device Managerp.19Figure 2.3: The (!) Indicates Improper Installationp.202.4 Device Setup & Configurationp.202.4.1 Setting Up the Devicep.20Figure 2.4: Device Manager Dialog Boxp.212.4.2 Configuring the Devicep.21Figure 2.5: The Device Setting Dialog Boxp.222.5 Device Testingp.222.5.1 Testing Digital Input Functionp.23Figure 2.6: Digital Input Tab in Device Test Dialogp.232.5.2 Testing Digital Output Functionp.23Figure 2.7: Digital Output Tab in Device Test Dialogp.242.6 Hardware Uninstallationp.24Figure 2.8: Unplug or Eject Hardware Dialogp.25Figure 2.9: Stop a Hardware device dialog boxp.25Chapter 3 Signal Connectionsp.283.1 Overviewp.283.2 I/O Connectorsp.283.2.1 Pin Assignmentp.28Figure 3.1: I/O Connector Pin Assignmentp.293.2.2 I/O Connector Signal Descriptionp.30I/O Connector Signal Descriptionp.303.2.3 LED Indicator Status Descriptionp.30LED Indicator Status Descriptionp.303.3 Isolated Digital Input Connectionsp.313.3.1 Single-ended Channel Connectionsp.31Figure 3.2: Isolated Digital Input Connectionsp.313.4 Relay Connectionsp.31Figure 3.3: Relay Output Channel Connectionsp.313.5 Field Wiring Considerationsp.32Appendix A Specificationsp.34A.1 Isolated Digital Inputp.34A.2 Relay Outputp.34A.3 Generalp.35Appendix B Function Blockp.38
Page 1 of the Advantech USB-4761 user manual — 8-channel Relay, 8-channel IDI USB Module
Page 1 · click to enlarge
Page 1

USB-4761

8-channel Relay, 8-channel IDI USB Module

User Manual

Page 2 of the Advantech USB-4761 user manual
Page 2 · click to enlarge
Page 2

The documentation and the software included with this product are copy- righted 2006 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this man- ual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reli- able. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use.

Intel and Pentium are trademarks of Intel Corporation.

Microsoft Windows and MS-DOS are registered trademarks of

Microsoft Corp.

All other product names or trademarks are properties of their respective owners.

Part No. 2003476100 1st Edition

Printed in Taiwan March 2006

USB-4761 User Manual ii

Copyright · Acknowledgements

Page 3 of the Advantech USB-4761 user manual
Page 3 · click to enlarge
Page 3

Product Warranty (2 years)

Advantech warrants to you, the original purchaser, that each of its prod- ucts will be free from defects in materials and workmanship for two years from the date of purchase.

This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper instal- lation. Advantech assumes no liability under the terms of this warranty as a consequence of such events.

Because of Advantech’s high quality-control standards and rigorous test- ing, most of our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you will be billed according to the cost of replacement materials, service time and freight. Please consult your dealer for more details.

If you think you have a defective product, follow these steps:

1. Collect all the information about the problem encountered. (For example, CPU speed, Advantech products used, other hardware and software used, etc.) Note anything abnormal and list any onscreen messages you get when the problem occurs.
2. Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available.
3. If your product is diagnosed as defective, obtain an RMA (return merchandize authorization) number from your dealer. This allows us to process your return more quickly.
4. Carefully pack the defective product, a fully-completed Repair and Replacement Order Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable container. A product returned without proof of the purchase date is not eligible for warranty service.
5. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer.
Page 4 of the Advantech USB-4761 user manual — CE
Page 4 · click to enlarge
Page 4

CE

This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This kind of cable is available from Advantech. Please contact your local supplier for ordering information.

Technical Support and Assistance

1. Visit the Advantech web site at www.advantech.com/support

where you can find the latest information about the product.

2. Contact your distributor, sales representative, or Advantech's cus-

tomer service center for technical support if you need additional assistance. Please have the following information ready before you call: - Product name and serial number - Description of your peripheral attachments - Description of your software (operating system, version, appli- cation software, etc.) - A complete description of the problem - The exact wording of any error messages

To assist us in making improvements to this manual, we would welcome comments and constructive criticism. Please send all such - in writing to: support@advantech.com

Safety Precaution - Static Electricity

Follow these simple precautions to protect yourself from harm and the products from damage.

1. To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards while the PC is on.
2. Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components.

USB-4761 User Manual iv

Document Feedback

Page 5 of the Advantech USB-4761 user manual — Table of Contents
Page 5 · Contents
Contents

Contents

Contentsp.5Chapter 1 Introductionp.81.1 Featuresp.81.1.1 Robust Protectionp.91.1.2 Wide Input Rangep.91.1.3 Reset Protection for Industrial Applicationsp.91.1.4 Plug & Play Functionp.91.2 Applicationsp.101.3 Installation Guidep.10Figure 1.1: Installation Flow Chartp.111.4 Software Overviewp.121.4.1 Programming Choices for DA&C Module:p.121.4.2 Device Driversp.121.5 Device Driver Programmingp.131.5.1 Programming Toolsp.131.5.2 Programming with Device Drivers Function Libraryp.141.5.3 Troubleshooting Device Drivers Errorp.14Chapter 2 Installationp.162.1 Unpackingp.162.2 Driver Installationp.17Figure 2.1: Advantech Automation Software Setupp.172.3 Hardware Installationp.18Figure 2.2: Device Name on the Device Managerp.19Figure 2.3: The (!) Indicates Improper Installationp.202.4 Device Setup & Configurationp.202.4.1 Setting Up the Devicep.20Figure 2.4: Device Manager Dialog Boxp.212.4.2 Configuring the Devicep.21Figure 2.5: The Device Setting Dialog Boxp.222.5 Device Testingp.222.5.1 Testing Digital Input Functionp.23Figure 2.6: Digital Input Tab in Device Test Dialogp.232.5.2 Testing Digital Output Functionp.23Figure 2.7: Digital Output Tab in Device Test Dialogp.242.6 Hardware Uninstallationp.24Figure 2.8: Unplug or Eject Hardware Dialogp.25Figure 2.9: Stop a Hardware device dialog boxp.25Chapter 3 Signal Connectionsp.283.1 Overviewp.283.2 I/O Connectorsp.283.2.1 Pin Assignmentp.28Figure 3.1: I/O Connector Pin Assignmentp.293.2.2 I/O Connector Signal Descriptionp.30I/O Connector Signal Descriptionp.303.2.3 LED Indicator Status Descriptionp.30LED Indicator Status Descriptionp.303.3 Isolated Digital Input Connectionsp.313.3.1 Single-ended Channel Connectionsp.31Figure 3.2: Isolated Digital Input Connectionsp.313.4 Relay Connectionsp.31Figure 3.3: Relay Output Channel Connectionsp.313.5 Field Wiring Considerationsp.32Appendix A Specificationsp.34A.1 Isolated Digital Inputp.34A.2 Relay Outputp.34A.3 Generalp.35Appendix B Function Blockp.38
Page 8 of the Advantech USB-4761 user manual — 1.1 Features
Page 8 · click to enlarge
Page 8

Chapter 1 Introduction

Thank you for buying the Advantech’s USB-4761 data acquisition mod- ule. The Advantech USB-4761 is a powerful data acquisition (DAS) module for the USB port. It features a unique circuit design and complete functions for data acquisition and control.

1.1 Features

USB-4761 has the most requested measurement & control functions:

  • 8 relay output (Form C) and 8 isolated digital input channels
  • LED indicators to show activated relays
  • High-voltage isolation on input channels (2,500 VDC)
  • High ESD protection (2,000 VDC)
  • Wide input range (5 ~ 30 VDC)
  • Interrupt handling capability
  • Supports USB 2.0
  • Bus-powered
  • Wiring terminal on Modules
Page 9 of the Advantech USB-4761 user manual — 1.1.1 Robust Protection
Page 9 · click to enlarge
Page 9

1.1.1 Robust Protection The USB-4761 digital input channels feature a robust isolation protection for industrial, lab and machinery automation applications. It durably withstands voltage up to 2,500 VDC, preventing your host system from any incidental harms. If connected to an external input source with surge protection, the USB-4761 can offer up to a maximum of 2,000 VDC ESD (Electrostatic Discharge) protection.

1.1.2 Wide Input Range The USB-4761 has a wide range of input voltage from 5 to 30 VDC, and it is suitable for most industrial applications with 12 and 24 VDC input volt- age.

1.1.3 Reset Protection for Industrial Applications When the system has undergone a hot reset (i.e. without turning off the system power), USB-4761 can either retain outputs values of each chan- nel, or return to its default configuration as open status, depending on its onboard jumper setting. This function protects the system from wrong operations during unexpected system resets.

1.1.4 Plug & Play Function USB-4761 is a portable Plug-&-Play device that fully complies with the USB 2.0 specification. During module installation, all bus-related config- urations such as base I/O address and interrupts are conveniently taken care of by the Plug-&-Play function. You have virtually no need to set any jumpers or DIP switches.

Page 10 of the Advantech USB-4761 user manual — 1.3 Installation Guide
Page 10 · click to enlarge
Page 10

1.2 Applications

  • Industrial On/Off control
  • Switch status sensing
  • Digital I/O control
  • Industrial and lab automation
  • SMT/PCB machinery
  • Semi-conductor machinery
  • PC-based Industrial Machinery
  • Testing & Measurement
  • Laboratory & Education
  • External relay driving

1.3 Installation Guide

Before you install your USB-4761 module, please make sure you have the following necessary components:

  • USB-4761 DAS Module
  • Shielded USB 2.0 cable (1.8 m)
  • Driver software Advantech DLL drivers (included in the companion CD-ROM)
  • Personal computer or workstation with a USB port (running Windows 2000, or XP)

Some application software is also available for enhanced operation. USB- 4761 works with ActiveDAQ, ActiveDAQ Pro, and other third-party software packages.

After you have the necessary components and maybe some accessories for enhanced operation of your USB DAS module, you can then begin the installation procedure. Figure 1.1 on the next page provides a concise flow chart to give a broad picture of the software and hardware installa- tion procedures.

Page 11 of the Advantech USB-4761 user manual — Figure 1.1: Installation Flow Chart
Page 11 · click to enlarge
Page 11
Advantech USB-4761 — Figure 1.1: Installation Flow Chart diagram (page 11)
Fig. 1 · Figure 1.1: Installation Flow Chart
Figure 1.1Installation Flow Chart
Page 12 of the Advantech USB-4761 user manual — 1.4 Software Overview
Page 12 · click to enlarge
Page 12

1.4 Software Overview

Advantech offers a rich set of DLL drivers, third-party driver support and application software to help fully exploit the functions of your USB-4761 module:

  • Device Drivers (on the companion CD-ROM)
  • LabVIEW driver
  • Advantech ActiveDAQ
  • Advantech ActiveDAQ Pro

1.4.1 Programming Choices for DA&C Module: You may use Advantech application software like Advantech Device Drivers. On the other hand, advanced users are allowed to use register- level programming as another option, although this is not recommended due to its laborious and time-consuming nature.

1.4.2 Device Drivers The Advantech Device Drivers software is included on the companion CD-ROM. Advantech’s Device Drivers features a complete I/O function library to help boost your application performance. The Advantech Device Drivers for Windows 2000/XP works seamlessly with develop- ment tools such as Visual C++, Visual Basic, Inprise C++ Builder, and Inprise Delphi.

Page 13 of the Advantech USB-4761 user manual — 1.5 Device Driver Programming
Page 13 · click to enlarge
Page 13

1.5 Device Driver Programming

This section will provide a roadmap to demonstrate how to build an appli- cation from scratch using Advantech Device Drivers with your favorite development tools such as Visual C++, Visual Basic, Delphi, or C++ Builder. The step-by-step instructions on how to build your own applica- tions using each development tool will be given in the Device Drivers Manual. Moreover, a rich set of example source code is also given for your reference.

1.5.1 Programming Tools Programmers can develop application programs with the following devel- opment tools:

  • Visual C++
  • Visual Basic
  • Delphi
  • C++ Builder

For instructions on how to begin programming in each development tool, Advantech offers a Tutorial Chapter in the Device Drivers Manual for your reference. Please refer to the corresponding sections in this chapter on the Device Drivers Manual to begin your programming efforts. You can also look at the example source code provided for each programming tool, since they can get you very well oriented.

The Device Drivers Manual can be found on the companion CD-ROM. Alternatively, if you have already installed the Device Drivers on your system, The Device Drivers Manual can be readily accessed through the Start button:

Start/Programs/Advantech Automation/Advantech Device Manager /Device Driver’s Manual

The example source code can be found under the corresponding installa- tion folder such as the default installation path:

For information about using other function groups or other development tools, please refer to Creating Windows 2000/XP Applications with Device Drivers chapter and the Function Overview chapter in the Device Drivers Manual.

\Program Files\Advantech\ADSAPI\Examples

Page 14 of the Advantech USB-4761 user manual — 1.5.2 Programming with Device Drivers Function Library
Page 14 · click to enlarge
Page 14

1.5.2 Programming with Device Drivers Function Library Advantech Device Drivers offer a rich function library that can be uti- lized in various application programs. This function library consists of numerous APIs that support many development tools, such as Visual C++, Visual Basic, Delphi and C++ Builder.

1.5.3 Troubleshooting Device Drivers Error Driver functions will return a status code when they are called to perform a certain task for the application. When a function returns a code that is not zero, it means the function has failed to perform its designated func- tion. To troubleshoot the Device Drivers error, you can pass the error code to DRV_GetErrorMessage function to return the error message. Alternatively, you can refer to the Device Drivers Error Codes Appendix in the Device Drivers Manual for a detailed listing of Error Codes, Error IDs and the Error Messages.

Page 15 of the Advantech USB-4761 user manual — Installation
Page 15 · click to enlarge
Page 15

Installation

This chapter has a package item check- list, proper instructions about unpack- ing and step-by-step procedures for both driver and USB installation..

Sections include:

  • Unpacking
  • Driver Installation
  • Hardware Installation
  • Device Setup & Configuration
  • Device Testing
  • Hardware Uninstallation
Page 16 of the Advantech USB-4761 user manual — 2.1 Unpacking
Page 16 · click to enlarge
Page 16

Chapter 2 Installation

2.1 Unpacking

After receiving your USB-4761 package, please inspect its contents first. The package should contain the following items:

  • USB-4761 Module
  • Shielded USB 2.0 Cable (1.8 m)
  • Companion CD-ROM (DLL driver included)
  • User Manual

The USB-4761 Module harbors certain electronic components vulnerable to electrostatic discharge (ESD). ESD could easily damage the integrated circuits and certain components if preventive measures are not carefully paid attention to. Before removing the module from the antistatic plastic bag, you should take following precautions to ward off possible ESD damage:

  • Touch the metal part of your computer chassis with your hand to discharge static electricity accumulated on your body. One can also use a grounding strap.
  • Make contact between the antistatic bag and ground before opening the bag.

After taking out the module, you should first:

Inspect the module for any possible signs of external damage (loose or damaged components, etc.). If the module is visibly damaged, please notify our service department or our local sales representative immedi- ately. Avoid using a damaged module with your system.

  • Avoid physical contact with materials that could hold static electricity such as plastic, vinyl and Styrofoam.
Page 17 of the Advantech USB-4761 user manual — 2.2 Driver Installation
Page 17 · click to enlarge
Page 17

2.2 Driver Installation

We recommend you install the software driver before you install the USB-4761 module into your system, since this will guarantee a smooth installation process.

The 32-bit DLL driver Setup program for the USB-4761 module is included on the companion CD-ROM that is shipped with your module package. Please follow the steps below to install the driver software:

1. Insert the companion CD-ROM into your CD-ROM drive.
2. The Setup program will be launched automatically if you have the auto-play function enabled on your system. When the Setup Program is launched, you’ll see the following Setup Screen.
Advantech USB-4761 — 2.2 Driver Installation diagram (page 17)
Fig. 2 · 2.2 Driver Installation
Figure 2.1Advantech Automation Software Setup
Page 18 of the Advantech USB-4761 user manual — 2.3 Hardware Installation
Page 18 · click to enlarge
Page 18
3. Click Continue , and select the Installation option
4. Select the specific device and then just follow the installation instructions step by step to complete your device driver installation and setup.

For further information on driver-related issues, an online version of the Device Drivers Manual is available by accessing the following path:

\Advantech Device Manager\Device Driver’s Manual

2.3 Hardware Installation

After the DLL driver installation is completed, you can now go on to install the USB-4761 module in any USB port that supports the USB 2.0 standard, on your computer. It is suggested that you refer to the com- puter’s user manual or related documentation if you have any doubts. Please follow the steps below to install the module on your system.

1. Touch the metal part on the surface of your computer to neutralize the static electricity that might be in your body.
2. Plug your USB module into the selected USB port. Hold the module only by its edges Plug the module firmly into place. Use of excessive force must be avoided; otherwise the module might get damaged.

Start\Programs\Advantech Automation

Page 19 of the Advantech USB-4761 user manual — Figure 2.2: Device Name on the Device Manager
Page 19 · click to enlarge
Page 19
Advantech USB-4761 — Figure 2.2: Device Name on the Device Manager diagram (page 19)
Fig. 3 · Figure 2.2: Device Name on the Device Manager
Figure 2.2Device Name on the Device Manager

Note: If your module is properly installed, you should see the device name of your module listed on the Device Manager tab. If you see your device name listed, but marked with an exclamation sign “!” (Fig. 2-4), it means your module has not been correctly installed. In this case, remove the mod- ule from Device Manager by selecting its device name and press the Remove button. Then go through the driver installation process again.

Page 20 of the Advantech USB-4761 user manual — 2.4 Device Setup & Configuration
Page 20 · click to enlarge
Page 20
Advantech USB-4761 — Figure 2.3: The (!) Indicates Improper Installation diagram (page 20)
Fig. 4 · Figure 2.3: The (!) Indicates Improper Installation
Figure 2.3The (!) Indicates Improper Installation

After your module is properly installed with your system, you can now configure your device using the Advantech Device Manager that has itself already been installed on your system during driver setup. A com- plete device installation procedure should include device setup, configu- ration and testing. The following sections will guide you through the Setup, Configuration and Testing of your device.

2.4 Device Setup & Configuration

Advantech Device Manager is a utility that allows you to set up, config- ure and test your devices, and later stores your settings in the system reg- istry. These settings will be used when you call the APIs of Advantech 32-bit DLL drivers.

2.4.1 Setting Up the Device Step 1: To complete the device setup and configuration procedures, you must first install the device along with its driver. (Please refer to the previous section of Chapter 2 for detailed installation instructions).

Page 21 of the Advantech USB-4761 user manual — Figure 2.4: Device Manager Dialog Box
Page 21 · click to enlarge
Page 21
2. You can view the device(s) already installed on your system (if any) in the Installed Devices list box. If you haven’t installed any devices, you might see a blank list.
Advantech USB-4761 — Figure 2.4: Device Manager Dialog Box diagram (page 21)
Fig. 5 · Figure 2.4: Device Manager Dialog Box
Figure 2.4Device Manager Dialog Box

2.4.2 Configuring the Device Step 3: Click “Setup” button and you will see the “Device Setting “dialog box as follow. On the Device Setting dialog box, you can set the DI inter- rupt trigger edge and the power-on DO values.

Page 22 of the Advantech USB-4761 user manual — 2.5 Device Testing
Page 22 · click to enlarge
Page 22
Advantech USB-4761 — Figure 2.5: The Device Setting Dialog Box diagram (page 22)
Fig. 6 · Figure 2.5: The Device Setting Dialog Box
Figure 2.5The Device Setting Dialog Box

Start/Programs/Advantech Automation/Advan- tech Device Manager/Device Driver’s Manual

for the firmware download utility guidance and further information.

2.5 Device Testing

Following the Setup and Configuration procedures to the last step described in the previous section, you can now proceed to test the device by clicking the Test Button in the I/O Device Installation dialog window. In the Device Test dialog window, you are free to test the functions of USB-4761 on Digital input and Digital output tabs.

Page 23 of the Advantech USB-4761 user manual — 2.5.1 Testing Digital Input Function
Page 23 · click to enlarge
Page 23

2.5.1 Testing Digital Input Function Click the Digital Input tab to show the Digital Input test panel as seen below. By the color of the LEDs, you can easily discern whether the sta- tus of each digital input channel is high or low.

Advantech USB-4761 — 2.5.1 Testing Digital Input Function diagram (page 23)
Fig. 7 · 2.5.1 Testing Digital Input Function
Figure 2.6Digital Input Tab in Device Test Dialog

2.5.2 Testing Digital Output Function Click the Digital Output tab to bring up the Digital Output test panel as shown below. By pressing the buttons on each tab, you can easily set each digital output channel as high or low for the corresponding port

Page 24 of the Advantech USB-4761 user manual — 2.6 Hardware Uninstallation
Page 24 · click to enlarge
Page 24
Advantech USB-4761 — Figure 2.7: Digital Output Tab in Device Test Dialog diagram (page 24)
Fig. 8 · Figure 2.7: Digital Output Tab in Device Test Dialog
Figure 2.7Digital Output Tab in Device Test Dialog

Only after your module device is properly set up, configured and tested, can the device installation procedure be considered complete. After the device installation procedure is completed, you can safely proceed to the next chapter, Signal Connections.

2.6 Hardware Uninstallation

Though the Advantech USB modules are hot swappable, we still recom- mend you to follow the hardware un-installation procedure to avoid any unpredictable damages to your device or your system.

1. Close the applications of the USB module (ex. Advantech Device Manager).
Page 25 of the Advantech USB-4761 user manual — Figure 2.8: Unplug or Eject Hardware Dialog
Page 25 · click to enlarge
Page 25
2. Right click the “Unplug or Eject Hardware” icon on your task bar.
Advantech USB-4761 — Figure 2.8: Unplug or Eject Hardware Dialog diagram (page 25)
Fig. 9 · Figure 2.8: Unplug or Eject Hardware Dialog
Figure 2.8Unplug or Eject Hardware Dialog
3. Select “Advantech USB4711 Device” and press “Stop” Button.
Advantech USB-4761 — Figure 2.8: Unplug or Eject Hardware Dialog diagram (page 25)
Fig. 10 · Figure 2.8: Unplug or Eject Hardware Dialog
Figure 2.9Stop a Hardware device dialog box
Page 26 of the Advantech USB-4761 user manual — Figure 2.8: Unplug or Eject Hardware Dialog
Page 26 · click to enlarge
Page 26
4. Unplug your USB device from the USB port.
Page 27 of the Advantech USB-4761 user manual — Signal Connections
Page 27 · click to enlarge
Page 27

Signal Connections

This chapter provides useful informa- tion on how to connect input and output signals to the USB-4761 via the I/O connectors..

Sections include:

  • Overview
  • I/O Connectors
  • Field Wiring Considerations
Page 28 of the Advantech USB-4761 user manual — 3.2 I/O Connectors
Page 28 · click to enlarge
Page 28

Chapter 3 Signal Connections

3.1 Overview

Maintaining good signal connections is one of the most important factors in ensuring that your application system is sending and receiving data correctly. A good signal connection can avoid unnecessary and costly damage to your PC and other hardware devices.

3.2 I/O Connectors

USB-4761 is equipped with plug-in screw-terminal connectors that facilitate connection to the module without terminal boards or cables.

3.2.1 Pin Assignment Figure 3.1 on next page shows the pin assignments for the five 10-pin I/O connectors on USB-4761.

Page 29 of the Advantech USB-4761 user manual — Figure 3.1: I/O Connector Pin Assignment
Page 29 · click to enlarge
Page 29
Advantech USB-4761 — Figure 3.1: I/O Connector Pin Assignment diagram (page 29)
Fig. 11 · Figure 3.1: I/O Connector Pin Assignment
Figure 3.1I/O Connector Pin Assignment
Page 30 of the Advantech USB-4761 user manual — 3.2.2 I/O Connector Signal Description
Page 30 · click to enlarge
Page 30

3.2.2 I/O Connector Signal Description

Table 3.1I/O Connector Signal Description

NO Normally Open pin of relay output

COM Common pin of relay output

NC Normally Close pin of relay output

IDInA Isolated digital input A

IDInB Isolated digital input B

3.2.3 LED Indicator Status Description The USB Module is equipped with a LED indicator to show the current status of the device. When you plug the USB device into the USB port, the LED indicator will blink five times and then stay lit to indicate that it is on. Please refer to the following table for detailed LED indicator status information.

Table 3.2LED Indicator Status Description

ON Device ready for work

Off Device not ready to work

Slow Blinking (5 times) Device Initialization

Fast Blinking (Depends on data transfer speed).

Signal Name Description · LED Status Description · Device working

Page 31 of the Advantech USB-4761 user manual — 3.4 Relay Connections
Page 31 · click to enlarge
Page 31

3.3 Isolated Digital Input Connections

3.3.1 Single-ended Channel Connections USB-4761 has 8 isolated digital input channels. Each of isolated digital input channel accepts 10~30 VDC voltage inputs, and accept bi-direc- tional input. It means that you can apply positive or negative voltage to an isolated input pin (Vin ). The figure below shows how to connect an external input source to one of the card's isolated input channels.

Advantech USB-4761 — 3.3 Isolated Digital Input Connections diagram (page 31)
Fig. 12 · 3.3 Isolated Digital Input Connections
Figure 3.2Isolated Digital Input Connections

3.4 Relay Connections

After power on, the initial relay output status is shown as below:

Advantech USB-4761 — 3.4 Relay Connections diagram (page 31)
Fig. 13 · 3.4 Relay Connections
Figure 3.3Relay Output Channel Connections
Page 32 of the Advantech USB-4761 user manual — 3.5 Field Wiring Considerations
Page 32 · click to enlarge
Page 32

3.5 Field Wiring Considerations

  • When you use USB-4761 to acquire data from outside, noises in the environment might significantly affect the accuracy of your measurements if due cautions are not taken. The following measures will be helpful to reduce possible interference running signal wires between signal sources and the USB-4761.
  • The signal cables must be kept away from strong electromagnetic sources such as power lines, large electric motors, circuit breakers or welding machines, since they may cause strong electromagnetic interference. Keep the analog signal cables away from any video monitor, since it can significantly affect a data acquisition system.
  • If the cable travels through an area with significant electromagnetic interference, you should adopt individually shielded, twisted-pair wires as the analog input cable. This type of cable has its signal wires twisted together and shielded with a metal mesh. The metal mesh should only be connected to one point at the signal source ground.
  • Avoid running the signal cables through any conduit that might have power lines in it.
  • If you have to place your signal cable parallel to a power line that has a high voltage or high current running through it, try to keep a safe distance between them. Or place the signal cable in a right angle to the power line to minimize the undesirable effect.
Page 33 of the Advantech USB-4761 user manual — APPENDIX
Page 33 · click to enlarge
Page 33

A

APPENDIX

Specifications

Page 34 of the Advantech USB-4761 user manual — A.2 Relay Output
Page 34 · click to enlarge
Page 34

Appendix A Specifications

A.1 Isolated Digital Input

Optical Isolation 2,500 VDC

Opto-isolator response time 25us

Input Voltage VIH (max.) 30VDC

VIH (min.) 5VDC

Input current 5VDC 1.2mA

12VDC 3.3mA

24VDC 6.9mA

30VDC 8.7mA

A.2 Relay Output

Relay Type Form C

Rating (Resistive) 30 VDC@1 A 110 [email protected] A 120 [email protected] A 240 [email protected] A

Max. Switching Power 62.5 VA, 60 W

Max. Switching Voltage 220 VDC,250 VAC

Max. Switching Current 5 A

Breakdown Voltage 1500 V

Operate time 5 ms max.

Release time 4 ms max.

Insulation Resistance 1X109 . (at 500 VDC)

Life Expectancy Mechanical 1X108 operations (typical)

Electrical 12 V@10 mA: 5X107 operations (typical) 6 V@100 mA: 1X107 operations (typical) 60 V@500 mA: 5X105 operations (typical) 30 V@1000 mA: 1X106 operations (typical) 30 V@2000 mA: 2X105 operations (typical)

Channels 8 · VIL (max,) 2VDC · Channels 8

Page 35 of the Advantech USB-4761 user manual — A.3 General
Page 35 · click to enlarge
Page 35

A.3 General

I/O Connector Type Removable 10-pin screw terminal x 5

Dimensions 132 X 80 X 32 mm (5.2” X 3.2” X 1.3”)

Power Consumption 60mA@+5V typical, 400mA@+5V max.

Temperature Operation 0~60 (32~140) (refer to IEC 68-2-1, 2)

Relative Humidity 5%~95% RH non-condensing (refer to IEC 68-2-1, 2)

Storage -20~70 (-4~158) · 29 Appendix A

Page 36 of the Advantech USB-4761 user manual — A.3 General
Page 36 · click to enlarge
Page 36
Page 36 of the Advantech USB-4761 user manual — A.3 General
Page 37 of the Advantech USB-4761 user manual — APPENDIX
Page 37 · click to enlarge
Page 37

B

APPENDIX

Function Block

Page 38 of the Advantech USB-4761 user manual — Appendix B Function Block
Page 38 · click to enlarge
Page 38

Appendix B Function Block

Advantech USB-4761 — Appendix B Function Block diagram (page 38)
Fig. 14 · Appendix B Function Block
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Advantech USB-4761

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Advantech USB-4761

Be the first to ask — other owners or our team will answer.

Original document

Advantech USB-4761 manual PDF

38 pages·748 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…