1/2/4 Port Ethernet to RS-232/422/485 Data Gateway User’s Manual

This document is copyrighted, 2001, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd., reserves the right to make improve- ments to the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements upon the rights of third parties which may result from its use.
The ADAM-4570/ADAM-4571/EDG-4504 has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the ADAM-4570/ADAM-4571/EDG-4504 system from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products.
3nd Edition Printed Taiwan January 2002
Copyright Notice · CE Notification

Advantech Customer Services Each and every Advantech product is built to the most exacting specifications to ensure reliable performance in the unusual and demanding conditions typical of industrial environments. Whether your new Advantech equipment is destined for the laboratory or the factory floor, you can be assured that your product will provide the reliability and ease of operation for which the name Advantech has come to be known.
Your satisfaction is our number one concern. Here is a guide to Advantech’s customer services. To ensure you get the full benefit of our services, please follow the instructions below carefully.
Technical Support We want you to get the maximum performance from your products. So if you run into technical difficulties, we are here to help. For most frequently asked questions you can easily find answers in your product documentation. These answers are normally a lot more detailed than the ones we can give over the phone.
Please consult this manual first. If you still cannot find the answer, gather all the information or questions that apply to your problem and, with the product close at hand, call your dealer. Our dealers are well trained and ready to give you the support you need to get the most from your Advantech products. In fact, most problems reported are minor and are able to be easily solved over the phone.
In addition, free technical support is available from Advantech engineers every business day. We are always ready to give advice on application requirements or specific information on the installation and operation of any of our products.

Product Warranty Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of purchase.
This warranty does not apply to any products which have been repaired or altered by other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability as a conse- quence of such events under the terms of this Warranty.
Because of Advantech’s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product ever does prove defective, it will be repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you will be billed according to the cost of replacement materi- als, service time and freight. Please consult your dealer for more details.
If you think you have a defective product, follow these steps:
3. If your product is diagnosed as defective, you have to request an RMA number. When requesting an RMA (Return Material Authori- zation) number, please access ADVANTECH’s RMA website: http:// www.advantech.com.tw/rma If the web sever is shut down, please contact our office directly. You should fill in the “Problem Repair Form”,describing in detail the application environment, configura- tion, and problems encountered. Note that error descriptions such as “does not work” and “failure” are so general that we are then required to apply our internal standard repair process.

product returned without dated proof of purchase is not eligible for warranty service.



3.2 Configuring the ADAM-4570/ADAM-4571/EDG-4504 The Configuration Utility 33
3.2.1 Search for Specific ADAM-4570/ADAM-4571/EDG-4504 34 3.2.2 System Configuration 36 3.2.3 Network Configuration 38 3.2.4 Port Configuration 39 3.2.4.1 Host/Device Idle Protection (ADAM-4570 only) 41 3.2.5 Security Configuration 47 3.3 Status Messages 48
3.3.1 Connection Diagnostic 48 3.4 Port Mapping Utility 50
3.4.1 Self Test Function 52 3.4.2 Upgrading ADAM-4570/ADAM-4571/EDG-4504s Firmware Download 54 3.4.3 Save The Configuration 57 3.4.4 Auto-reconnect function 58





Table 2-1 ADAM-4570 LED Definition 13 Table 2-2 ADAM-4571 LED Definition 15 Table 2-3 EDG-4504 LED Definition 17

Overview

1.1 Introduction
The ADAM-4570/ADAM-4571/EDG-4504 is a light- ning fast and cost effective data gateway between RS- 232/422/485 and Ethernet interfaces. This unit imme- diately upgrades your existing device(s) to the Ethernet world. Functionally transparent and efficient, the ADAM-4570/ADAM-4571/EDG-4504 is specially designed for remotely controlling and monitoring de- vices via the Internet.
The ADAM-4570/ADAM-4571/EDG-4504 provides one, two or four RS-232/485/422 serial ports that can each be easily configured for your needs. For increas- ing the reliability of systems, the ADAM-4570 also pro- vides three significant functions: Host idle, Device idle and Auto-reconnect. The ADAM-4570/ADAM-4571/ EDG-4504 also supports transmission speeds up to 230 Kbps, meeting the demand for today’s high-speed ex- change. Users can use a Windows utility to configure the ADAM-4570/ADAM-4571/EDG-4504 without need for further programming. The ADAM-4570/ ADAM-4571/EDG-4504 not only protects your cur- rent hardware investment but also ensures future net- work expandability. Since the protocol conversion is transparent, all existing devices can be seamlessly inte- grated into the Ethernet network. Therefore, the ADAM-4570/ADAM-4571/EDG-4504 can be used in security systems, factory automation, SCADA, trans- portation and more.
The ADAM-4570/ADAM-4571/EDG-4504 inte- grates both your existing human-machine interface soft- ware (HMI) and RS-232/422/485 system architecture with an Ethernet network. The result helps save cabling

space and software development cost. The ADAM- 4570/ADAM-4571/EDG-4504 also provides a high- performance RISC CPU and real time operating sys- tem to reduce CPU load. These components make the ADAM-4570/ADAM-4571/EDG-4504 more stable and reliable. Another benefit is the ADAM-4570/ ADAM-4571/EDG-4504 allows users to remotely download programs to a designated device via Ethernet. This reduces the need for on-site maintenance and di- agnosis. In addition, the ADAM-4570/ADAM-4571/ EDG-4504 comes with a Windows configuration and port-mapping utility. This configuration tool can auto- detect all Ethernet Data Gateway products on a local network. It also lets users easily adjust all settings. The port mapping utility helps to set up COM ports for one Windows 95/98/NT/2000/XP platform. This helps us- ers manage all ports to meet their needs.
Host/Device Idle Protection empowers the reliabil- ity of system (ADAM-4570)
For improving the stability of systems, users usually have to spend lots of effort to build up “Redundant” func- tionality. Now, the ADAM-4570 provides new pow- erful functions that help users build up redundant sys- tems fast and easily: The new functions are Host idle & Device idle.
The purpose of the “Host idle switch” function is to prevent system hang-up from occurring due to applica- tion program failure. If the application program fails, the ADAM-4570 will cut off the connection between the host PC and the ADAM-4570. Another PC can then start to access the same ADAM-4570. Also, if

the serial device or communication between the device and the ADAM-4570 fails, the “Device Idle” function will switch the communication port from one port to another port to keep com- municating with another device automatically. Thus, another de- vice can send data to the ADAM-4570.
Auto-reconnect after networking breaks
Sometimes, the system crashes because the ADAM-4570/ ADAM-4571/EDG-4504 is interrupted or powered-off by ac- cident. The ADAM-4570/ADAM-4571/EDG-4504 provides an “Auto-reconnect” function to solve this problem. When the ADAM-4570/ADAM-4571/EDG-4504 is powered-off acci- dentally, the driver will keep trying to reconnect the ADAM- 4570/ADAM-4571/EDG-4504 automatically. When the ADAM-4570/ADAM-4571/EDG-4504 recovers or is pow- ered-on, due to this auto-reconnect function, the host PC can send commands to the ADAM-4570/ADAM-4571/EDG-4504 again. This function enhances the reliability of the system.
Auto-detect Ethernet Data Gateway products
The configuration utility can search all the Ethernet Data Gate- way devices on the network automatically and configure them according to the current network status, saving your effort to acquire the status information yourself.
Easy to diagnose the communication situation
If this test item is selected, an internal test will be done on the RS-232 serial port, and the result (successful or failed) will be displayed when the test is completed. If this test item is selected, an external test will also be done to check that the connection signals for each port are working properly. For the external test, you will need to connect each port to a loopback tester. The test

is divided into two parts: Signal test and Communication Param- eters test. If the results are OK, users can be sure the communi- cation quality between host PC and ADAM-4570/ 4571 is OK.
Easy to maintain by downloading firmware remotely
Advantech continually upgrades ADAM-4570/ADAM-4571/ EDG-4504’s firmware to keep pace with the ever-expanding world of computing. You can use the Download function located on the Port Mapping utility to carry out the upgrade procedure. Please access Advantech’s Web site to download the required computer file and then follow the instructions.
1.2 Features
Chapter 1 Introduction 5

1.3 Specifications

DIN-rail, panel mounting (EDG-4504)
1.4 Package Checklist
Chapter 1 Introduction 7




In this chapter, you will be given an overview of the ADAM-4570/ADAM-4571/EDG-4504 hardware installation procedures. As mentioned in the previous chapter, the ADAM-4570/ADAM-4571/EDG-4504 comes ready for all network connections, including Ethernet, and RS-232/422/485 port connections.
We begin this chapter with a brief showing the installation procedure. You can take flow chart for reference.

Figure2-1 Installation Flow Chart

2.1 Understanding the ADAM-4570/ADAM-4571/EDG-4504
The ADAM-4570/ADAM-4571/EDG-4504 is an advanced data gateway unit. It extends traditional COM ports of a PC with access over a TCP/IP network. Through networking, you can control and monitor remote serial devices either over a LAN or over the WAN.
Since the ADAM-4570/ADAM-4571/EDG-4504 is connected through a TCPIP network, you will need to know some basic facts about networking in order to get the server hooked up correctly.
2.1.1 Network Architecture
Traditional serial port communication uses a COM port board that slides into one of the slots at the back of your PC. In this case, only the computer containing the board can access the serial port. With the ADAM-4570/ADAM-4571/EDG-4504, you are now able to access the COM port from a distance through local area network. The ADAM-4570/ADAM-4571/EDG- 4504 can be integrated within the network architecture of any protocol. Note, all serial devices which are connected to the port must have the same protocol running and the same trans- mission speed. Connect devices running different protocols to different ports of the ADAM-4570/ADAM-4571/EDG-4504.
Chapter 2 Getting Started 11

The following illustration shows the network architecture as be- low:

Figure 2-2 Network Architecture(1)

Figure 2-3 Network Architecture(2)

2.1.2 Top / Front / Rear View
There are five network status LEDs located on the top panel of ADAM-4570, each with its own specific function.

Table 2-1 ADAM-4570 LED Definition
Chapter 2 Getting Started 13


Figure 2-4 ADAM-4570—Top Panel

Figure 2-5 ADAM-4570—Front Panel

Figure 2-6 ADAM-4570—Back Panel

There are four LEDs located on the top panel of ADAM-4571, each with its own specific function.

Table 2-2 ADAM-4571 LED Definition
Chapter 2 Getting Started 15


Figure 2-7 ADAM-4571—Top Panel

Figure 2-8 ADAM-4571—Front Panel

Figure 2-9 ADAM-4571—Back Panel

There are 13 LEDs located on the top panel of EDG-4504, each with its own specific function.

Table 2-3 EDG-4504 LED Definition
Chapter 2 Getting Started 17


Figure 2-10 EDG-4504—Top Panel

Figure 2-11 EDG-4504—Front Panel

Figure 2-12 EDG-4504—Front Panel

2.1.3 Stickers
If you forgot the IP addresses of specific ADAM-4570/ADAM- 4571/EDG-4504s or where the host PC is mapped to the ADAM-4570 port, we have provided five stickers for you to note the IP addresses and place in a secure location. For ex- ample,
160.59.20.89: The IP address of the specific host PC mapped to this port.
Chapter 2 Getting Started 19

2.2 Connecting the Hardware
Next, we will explain how to find a proper location for your EDG COMPort series, and then explain how to connect to the network, hook up the power cable, and connect to the ADAM- 4570/ADAM-4571/EDG-4504’s serial port.
4504, you can install other communication cards first.
2.2.1 Choosing a Location
Due to its versatility and innovative design, the ADAM-4570/ ADAM-4571 can be:

The ADAM-4570/ADAM-4571 can be attached to a wall us- ing the included metal brackets. Each bracket comes with four screws; first attach the brackets to the bottom of the ADAM- 4570/ADAM-4571. Next, screw each bracket to a wall.

Figure 2-13 Panel Mounting
Chapter 2 Getting Started 21
Panel Mounting

You can mount the ADAM-4570/ADAM-4571 on a standard DIN Rail. First, using two screws, attach the metal plate to the DIN Rail bracket. Because the screw heads are beveled, the tops of the screws will be flush with the metal plate. Din Rail Mounting Brackets—Orientation of Metal Plates
You can now screw the metal plate with the DIN rail bracket assembly to the bottom of the server is a more convenient way. Next, use the remaining screws to put the metal plate on the bottom of the ADAM-4570/ADAM-4571.

Figure 2-14 Din Rail Mounting
DIN Rail Mounting

ADAM-4570/ADAM-4571 can be stacked as seen in the fig- ure below.

Chapter 2 Getting Started 23
Piggyback Stack · Figure2-15 Piggyback Stack


Figure 2-16 Din Rail Mounting

Figure 2-17 Panel Mounting

2.2.2 Network Connection
There are two ways to use the 10/100Base-T Ethernet connec- tor located on the ADAM-4570/ADAM-4571/EDG-4504 :
Cabling requirements for the Ethernet side
Use an RJ-45 connector to connect the Ethernet port of the ADAM-4570/ADAM-4571/EDG-4504 to the network hub. The cable for connection should be Category 3 (for 10Mbps data rate) or Category 5 (for 100 Mbps data rate) UTP/STP cable, which is compliant with EIA/TIA 586 specifications. Maximum length between the hub and any ADAM-4570/ ADAM-4571/EDG-4504 is up to 100 meters (ca. 300 ft).

Figure 2-18 Connecting ADAM-4570/ADAM-4571/EDG-4504 series to
Chapter 2 Getting Started 25
the hub

2.2.3 Power Connection
You should take the following steps to connect ADAM-4570/ ADAM-4571/EDG-4504 power. 1. Connect the power cable to 2-pin connector 2. Connect power cable to power adapter

Figure 2-19 Power Connection for ADAM-4570/4571

Figure 2-20 Power Connection for EDG-4504
If the ADAM-4570/ADAM-4571/EDG-4504 is working prop- erly, the green power LED will light up , indicating that the ADAM-4570/ADAM-4571/EDG-4504 is receiving power. Furthermore, the ADAM-4570/ADAM-4571/EDG-4504 pro- vides surge protection to protect it from being damaged by over- voltage, a 34V surge protection is added to the power end and an 18V surge protection is for the RS-422/485 end.

2.2.4 Serial Connection
The model of the ADAM-4570/4571 that you purchased has RJ-48 serial ports on the bottom of module. Depending on your serial device and serial interfaces, there are two options:
Figure 2-21 Serial Connection for ADAM-4570/4571
Chapter 2 Getting Started 27

PIN Name DCD RX TX DTR GND DSR RTS CTS RI
RJ-48 1 2 3 4 5 6 7 8 9


The model of the EDG-4504 that you purchased has DB-9 se- rial ports on the bottom of module. Depending on your serial device and serial interfaces, there are two options:
Figure 2-22 Serial Connection for EDG-4504
Chapter 2 Getting Started 29




3.1 Driver and Utility Installation
In order to use a PC via an Ethernet network to control serial devices connected to the ADAM-4570/ADAM-4571/EDG- 4504, you must first have a host running Windows 95/98/ME/ NT/2000/XP. This type of application also requires the host to have an Ethernet card and TCP/IP protocol installed. Following are the installation instructions to set up the ADAM-4570/ ADAM-4571/EDG-4504.
2.Use your Windows Explorer or the Windows Run command to execute the Setup program (the path for the Setup program on the CD-ROM should be D:\ADAM4570\utility&driver\ portmaputility1.01\setup.exe, if your default floppy drive is D:).


Figure 3-1 Configuration Utility
3.2 Configuring the ADAM-4570/ADAM-4571/EDG-4504 — The Configuration Utility
The ADAM-4570/ADAM-4571/EDG-4504 provides easy Windows configuration through Ethernet connection. This Windows utility searches all the ADAM-4570/ADAM-4571/ EDG-4504 and devices on the network automatically and you can configure various parameters for TCP/IP configuration eas- ily. For secure administration, it can also restrict the access rights for configuration to only one host PC to enhance network secu- rity. With this secure function enabled, other PCs will not have permission for configuration. The Windows utility consists of four functional categories: System, Network, Port, and Security which are presented on the toolbar of the configuration utility.
tings for each category, please follow the steps described below to make thse settings effective on the ADAM-4570/ ADAM-4571/EDG-4504.
è è

3.2.1 Search for Specific ADAM-4570/ADAM-4571/ EDG-4504
If you want to locate specific ADAM-4570/ADAM-4571/EDG- 4504s, the configuration utility provides a “Locate” function to assist you. You can select all the ADAM-4570/ADAM-4571/ EDG-4504 devices (see Figure 3-2) or select a group of ADAM- 4570s (see Figure 3-3) or just select one ADAM-4570 (see Figure 3-4). When you select a specific device, the LED that stands for “Status” will glow for 8 minutes. When you select another device, the original “Status” LED will turn off. Please follow these steps:

Figure 3-2 Locate all ADAM-4570/ADAM-4571/EDG-4504
1.Select “Designated” and select “ADAM-4570”


Figure 3-3 Locate the desired group of ADAM-4570s

Figure 3-4 Locate specific ADAM-4570s

3.2.2 System Configuration

Figure 3-5 System Setting Window
Configuration utility can only search the ADAM-4570/ADAM- 4571/EDG-4504 devices on the local network segment and cannot search beyond a router or gateway. Make sure that all the ADAM-4570/ADAM-4571/EDG-4504 devices that you want to monitor must reside on the same local network segment with the host PC.
In this column, you will see all the found ADAM-4570/ADAM- 4571/EDG-4504 devices are listed when you use the configura- tion utility to auto-search ADAM-4570/ADAM-4571/EDG- 4504 devices. The specific number following each ADAM-4570/ ADAM-4571/EDG-4504 device is its MAC Address. The MAC Address is what helps the local system to identify and locate each Ethernet data gateway device. This MAC Address is al- ready set before delivery from factory, hence no need for further configuration.
Ethernet Data Gateway

Configuration utility provides a default name for device to distin- guish a specific ADAM-4570/ADAM-4571/EDG-4504 from other ADAM-4570/ADAM-4571/EDG-4504. You can update the default device name based on your application. Names longer than 128 characters cannot be used. It is best to choose a name you can remember.
This field is to record the function, application and other infor- mation for each ADAM-4570/ADAM-4571/EDG-4504 device in more detail for easy management and maintenance. You are allowed to describe in your own words.
In this field, the configuration utility represents the firmware ver- sion of the ADAM-4570/ADAM-4571/EDG-4504. You might need to refer to the firmware version to determine functions avail- able on the ADAM-4570/ADAM-4571/EDG-4504 device. In case of problems that might concern the firmware version, please provide the firmware version number to our Customer Service.
Each ADAM-4570/ADAM-4571/EDG-4504 offers three se- rial interfaces, RS-232, RS-485 and RS-422. You can use any one of these serial interfaces according to your requirements.

3.2.3 Network Configuration

Figure 3-6 Network Configuration Window
This does not need configuration.
This function will show the current linking speed to be either 10Mbps or 100Mbps. However, the utility will auto-detect the current transmission speed on the network segment and set the transmission speed for the device accordingly without your fur- ther efforts.
The utility will detect the current transmission mode (half-duplex or full-duplex) on the network segment, and set the transmission mode for the device accordingly without your further efforts.
MAC Address · Link Speed · Duplex Mode

IP address, Subnet Mask, Default Gateway
The IP address identifies your ADAM-4570/ADAM-4571/ EDG-4504 device on the global network. Each ADAM-4570/ ADAM-4571/EDG-4504 has same default IP address 10.0.0.1. Obtain a specific IP address from your network administrator and then configure each ADAM-4570/ADAM-4571/EDG-4504 with the individual IP address.
support auto IP address configured by DHCP server.
3.2.4 Port Configuration

Figure 3-7 Port Configuration Window

To specify which port on the ADAM-4570/ADAM-4571/EDG- 4504 is to be connected to the serial device.
You can give more detailed description of the function of the port for easy management and maintenance. Descriptions longer than 128 characters cannot be used.
Each ADAM-4570/ADAM-4571/EDG-4504 offers three kinds of serial interfaces, RS-232, RS-485 and RS-422. You can use any of the three serial interfaces according to your requirements.
The ADAM-4570/ADAM-4571/EDG-4504 provides five options: Even, Odd, None, Space, Mark.
The ADAM-4570/ADAM-4571/EDG-4504 provides four options: None, Xon/Xoff, RTS/CTS, DTR/DSR.
The ADAM-4570/ADAM-4571/EDG-4504 provides four options: 5, 6, 7 or 8.
The ADAM-4570/ADAM-4571/EDG-4504 provides three options: 1, 1.5 or 2.
The ADAM-4570/ADAM-4571/EDG-4504 supports baud rates from 300 to 230,000 bps.

3.2.4.1 Host/Device Idle Protection (ADAM-4570 only)
When building up a system, users sometimes face the following problems. The system crashes because the serial/Host device breaks down; the application program fails or the cable between the host device and the ADAM-4570 breaks etc. For keeping the stability of system, the users usually have to spend lots of efforts to build up “Redundant” function. Now the ADAM-4570 provides new powerful functions to help users to build up it fast and easily. Focusing on Host PC, serial device, ADAM-4570, the new functions are: Host idle switch, device idle switch and auto-reconnect (refer to Chapter 3.4.4).
Host Idle Switch Mode When the application program which is running in host PC fails, the ADAM-4570 and the serial device always “Hang up”. The data can not be sent to other PC. The purpose of the “Host idle switch” mode is to prevent this system hang-up from occurring due to the above problems. If the application program fails, the ADAM-4570 will cut off the connection between the host PC and the ADAM-4570. Another PC can then start to access the same ADAM-4570. Below illustrates the behavior of the ADAM-4570.




The “Timing” is the time that the ADAM-4570 will wait to receive commands from the host PC. If the ADAM-4570 does not receive any commands from the host PC over this user set period of time, the ADAM-4570 will automatically cut off the connection. The time limitation (seconds) ranges from 1 ~ 4095

Configuration Steps


Device Idle Switch Mode
When the serial device or communication between the device and the ADAM-4570 fails, the data can not be sent to the host PC in the set time period. The purpose of the “Device idle switch” mode is to provide another communication link to the serial device. If the serial device or communication be- tween the device and the ADAM-4570 fails, the ADAM- 4570 will switch the communication port from port 1 to port 2 to keep communicating with device B automatically. Thus, de- vice B can send data to ADAM-4570’s port 2. An illustration of this configuration follows.

The C O M 25 of host PC receives the data



The “Timing” is the period of time that the ADAM-4570 will wait to receive data from the serial device. If the ADAM- 4570 does not receive any data from the device over the pe- riod of time the user sets up, the ADAM-4570 will switch the communication port to another one. The time limitation (sec- onds) is from 1 ~ 4095
Configuration Steps

3.2.5 Security Configuration
Figure 3-9 Security configuration
Only configure the authorized IP
This option is enabled in order to protect all configuration settings from being changed inadvertently.
Allow any IP to access
If this option is enabled, any PC can access data from this ADAM-4570/ADAM-4571/EDG-4504.
The specified IP which can access
If you do not want many PCs to have the access right, you can limit at most 32 PCs to access data from this ADAM-4570/ ADAM-4571/EDG-4504.

3.3 Status Messages
The status message shown at the bottom of the utility window reflects the current status of ADAM-4570/ADAM-4571/EDG- 4504.
Figure 3-10 Status messages
The configuration utility has found the ADAM-4570/ADAM- 4571/EDG-4504 and it is ready for use.
The configuration utility is searching the ADAM-4570/ADAM- 4571/EDG-4504
“Querying DATA from EDG COMport”
The configuration utility is getting data from the ADAM-4570/ ADAM-4571/EDG-4504.
“Read” · “Searching EDG COMport”

The ADAM-4570/ADAM-4571/EDG-4504 is ready to be configured and is now waiting for acknowledgement from the device.
“Lost Connection from the Device”
Due to device shut down or network failure, the configuration utility has lost connection after 5 seconds.
“Fail to apply this setting to the device”
Specific settings are not accepted by ADAM-4570/ADAM- 4571/EDG-4504.
“The device fails to respond”
The connected device does not respond.
“Fail to reset the device”
Fail to reset the ADAM-4570/ADAM-4571/EDG-4504.
3.3.1 Connection Diagnostic
When you complete the configuration of your ADAM-4570/ ADAM-4571/EDG-4504s, you can follow the steps to check if the ADAM-4570/ADAM-4571/EDG-4504 connects to net- work or not.
“Device Ready”

at the remote site to check and see if the power is on, and make sure that the connection is okay.
3.4 Port Mapping Utility
The purpose of the port mapping utility is to help you manage all ports which are in one Windows NT or Windows 2000 plat- form. The utility displays three types of ports: Used ports, Un- used ports and ADAM-4570/ADAM-4571/EDG-4504 ports. Please follow the steps.

Figure 3-11 Unused ports
2.Click ADD button to assign the COMport to the specific ADAM-4570/ADAM-4571/EDG-4504.


Figure 3-12 Assign COM port to ADAM-4570/ADAM-4571/EDG-4504

Figure 3-13 Warning window


3.4.1 Self Test Function
The purpose of this test is to make sure the communication from host PC to ADAM -4570 is OK. If there is still an error, you can check the communication from the ADAM-4570/ADAM- 4571/EDG-4504 to the serial devices.
If the test is selected, an external test will be done to check that the connection signals for each port are working properly. For the test, you will need to connect each port to a loopback tester (provided in the package). Refer to the following chart for the specifications of this loopback tester. The loopback test only applies to RS-232 mode. The test is divided into two parts: Signal test and Communication Parameters test.

Figure 3-14 Test window

2.Click OK button to return to the port mapping window. All the ports in the ADAM-4570/ADAM-4571/EDG-4504 are tested ok.

Figure 3-15 Loopback test
3.4.2 Upgrading ADAM-4570/ADAM-4571/EDG- 4504’s Firmware Download
Advantech continually upgrades its firmware to keep pace with the ever-expanding world of computing. You can use the Down- load function located on Port Mapping utility to carry out the upgrade procedure. Please access Advantech’s Web site at http://www.advantech.com to download the required computer file and then follow these instructions.

Figure 3-16 Update firmware window

Figure 3-17 Select the file


Figure 3-18 Download firmware
reboot ADAM-4570/ADAM-4571/EDG-4504 untill no application program access this ADAM-4570/ADAM- 4571/EDG-4504.

3.4.3 Save The Configuration
If you want to save or recover the configuration, you can select the “Import/Export” items.



3.4.4 Auto-reconnect function
Sometimes, the system crashes because the ADAM-4570 is in- terrupted or is powered-off by accident. Users want the host PC to re-connect to the ADAM-4570 automatically after such an occurrence. The ADAM-4570 provides an “Auto-reconnect” function to solve this problem. When the ADAM-4570 is pow- ered-off accidentally, the driver will keep trying to reconnect the ADAM-4570 automatically. When the ADAM-4570 recovers or is powered-on, due to this auto-reconnect function, the host PC’s commands will be received by the ADAM-4570 again. This function enhances the reliability of the system.


This chapter explains how to solve some of the most common problems you could encounter while using ADAM-4570/ ADAM-4571/EDG-4504. If you are still having problems after reading this chapter, contact your dealer, or e-mail Advantech for help.
“Configuration Utility can not find ADAM-4570/ADAM- 4571/EDG-4504”
“Configuration utility can find ADAM-4570/ADAM-4571/ EDG-4504 but cannot access ADAM-4570/ADAM-4571/ EDG-4504”

For security reasons, and to simplify operations, users can give the access right to specific PC. Only these PCs can g e t data from ADAM-4570/ADAM-4571/EDG-4504. Thus, if while using the ADAM-4570/ADAM-4571/EDG-4504, it is advised that you check to see if your PC is on the access right list.
“Cannot change the IP address or other server proper- ties”
The network administrator is the only one allowed to modify the ADAM-4570/ADAM-4571/EDG-4504’s configuration. Keep in mind, even when multiple hosts share the same net- work, administrative access is still protected. If you need to change any configu ration settings, ask your network administra- tor for assis tance.
“The host PC can acess the ADAM-4570/ADAM-4571/ EDG-4504 at this local site but later moves the ADAM- 4570/ADAM-4571/EDG-4504 to a remote site that PC can- not access.”
Due differing network interface connections, your IP address might have changed, and as a result, you are no longer on the ADAM-4570/ADAM-4571/EDG-4504’s Access Control list.
To resolve this issue:
Chapter 4 Troubleshooting 59


Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.