MX410/MX412 System Manual Document Number: 61 189500L1-1B August 2005 PRELIMINARY ®.
MX410/MX412 System Manual ii PRELIMINARY 61189500L1-1B Front Matter T rademar ks Any brand names and product names includ ed in this manual are trademarks, registered trademarks, or trade names of their respectiv e holders. T o the Holder of the Manual The contents of this publication are current as of the d ate of publication.
MX410/MX412 System Manual 61189500L1-1B PRELIMINARY iii R e vision Histor y Con v entions The following typographical conventi ons are used in this document: This font indicates a cross-reference link. First-ti me references to tables and figures are shown in this font .
MX410/MX412 System Manual iv PRELIMINARY 61189500L1-1B Compliance The MX410 (P/N 118950 0L1) and MX412 (P/N 1 189512L1) comply with the requirement s covered under UL 609 50 and NEBS Level 3. The MX410 and MX412 are intended to be installed in a restrict ed access area only.
MX410/MX412 System Manual 61189500L1-1B PRELIMINARY v T r aining ADTRAN offers training courses on ou r produc ts. These courses includ e overviews on product features and functions while covering applicat ions of ADTRAN’s prod uct lines.
MX410/MX412 System Manual vi PRELIMINARY 61189500L1-1B This page is intentionally blank..
61189500L1-1B PRELIMINARY vii MX410/MX412 System Manual Contents Section 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Product Overview . . . .
MX410/MX412 System Manual viii PRELIMINARY 61189500L1-1B Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 MX410 . . . . . . . . . . . .
Contents 61189500L1-1B PRELIMINARY ix DS1 Test Pattern Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-45 Performance Monitoring Menu . . . . . . . . . . . . . . . . . . . . . . .
MX410/MX412 System Manual x PRELIMINARY 61189500L1-1B Figures Figure 1-1. MX410 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Figure 1-2. MX412 Overview . . . . . . . . . . .
Contents 61189500L1-1B PRELIMINARY xi Figure 5-18. Network Management Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 -31 Figure 5-19. Ethernet Menu . . . . . . . . . . . . . . . . . . . . . . . . . . .
MX410/MX412 System Manual xii PRELIMINARY 61189500L1-1B Table 5-10. Cross-Connect Mapping Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25 Table 5-11. Performance Monitoring Definitions . . . . . . . . . . . .
61189500L1-1B PRELIMINARY 1-1 Section 1 Intr oduction PR ODUCT OV ER VIEW The MX410/MX412 delivers full DS0 control to se rvice locations, allowing carriers full utili- zation of DS1 b andwidth. The MX410 interfaces to four lon g-haul outsi de plant protected DS1s via RJ-48 connectors, while the MX412 inte rfaces to 12 DS1s.
Product Overview MX410/MX412 System Manual 1-2 PRELIMINARY 61189500L1-1B The major features of the MX 410/MX412 are as follows: • 19-inch wall mounting or rack mounting, one rack unit high • Front panel data connections •O n e V .
MX410/MX412 System Manual Produ ct Overview 61189500L1-1B PRELIMINARY 1-3 Figure 1-2. MX412 Overview 4 x 10/100 Ethernet FXS 4 x RS-232 E911, etc. Digital Radios Data Analog Radios Data Grooming of DS0S LAN Extension over PPP for Remote Management Star Configuration of Backhaul Backhaul 12 x T1 V.
Product Overview MX410/MX412 System Manual 1-4 PRELIMINARY 61189500L1-1B This page is intentionally blank..
61189500L1-1B PRELIMINARY 2-1 Section 2 Engineering Guidelines GENER AL This section provid es engineer ing guidelines for network desi gners who are incorporating an MX410 or MX412 system into their networ k.
Power Dissipation MX410/MX412 System Manual 2-2 PRELIMINARY 61189500L1-1B P OWER DISSIPA TION Table 2-3 provides the h eat dissipation data at –48 VDC (o perating range of –42 VDC to –60 VDC) and ±24 VDC (ope rating range of ±22 VDC to ±27 VDC ) with redundant PSUs installed (MX410 only).
61189500L1-1B PRELIMINARY 3-1 Section 3 A pplica tion Guidelines INTRODUCTION This section describes several applications for the MX410/MX412 system. For each appli- cation there is a figure illustrating the app lication, a list of the equipment needed, and an explanation of the basic setup.
MX410/MX412 System Manual 3-2 PRELIMINARY 61189500L1-1B MX410 DA TA P A TH BLOCK DIAG RAM As shown in Figure 3-1 , the MX410/MX412 contains a 1/0 cr oss connect that allows DS0s to be mapped betw een four DS1s (12 DS1s on the M X412), four PPP ports, and a V.
MX410/MX412 System Manual Dr op and Co ntinue Application 61189500L1-1B PRELIMINARY 3-3 Dr op and Continue A pplica tion The following applies to Remote Site #1 shown in Figure 3-2 .
Drop and Continue Application MX410/MX412 System Manual 3-4 PRELIMINARY 61189500L1-1B Setup Connect the incoming DS1 (the DS1 from which the DS0s are dropped) to the DS1 1 RJ. Connect the outgoing DS1 to the DS1 2 RJ. Connect the other DS1s using the R J connector on the front pan el.
MX410/MX412 System Manual Dr op and Co ntinue Application 61189500L1-1B PRELIMINARY 3-5 Figure 3-4 shows the Quick Setup menu af ter DS0s 21-22 have been dropped from DS 1 1 to PPP1, DS0s 23-24 have been dropped from DS1 1 to the V.35 port. Figure 3-4.
Drop and Continue Application MX410/MX412 System Manual 3-6 PRELIMINARY 61189500L1-1B Figure 3-6 shows the Cross-Connect Mapping menu after the remaining DS0s have been continued to DS1 2 as well as 4 DS0s (13-16) dropped to DS1 3 (1-4) and four other DS0s (17-20) droppe d to DS1 4 (1-4).
MX410/MX412 System Manual Drop and Insert Applica tion 61189500L1-1B PRELIMINARY 3-7 Dr op and Inser t A pplica tion The following applies to Remote Si te #1 shown in Figure 3-7 . In the Drop and Insert Appli- cation DS0s from one DS 1 can be dropped out to the other DS1 p orts.
Drop and Insert Application MX410/MX412 System Manual 3-8 PRELIMINARY 61189500L1-1B Setup Connect the DS1 from which the DS0s will be dropped to the DS1 1 RJ. Connect th e other DS1 to which the DS0s will be inserted to th e DS1 2 RJ. Connect the other DS1s using the other RJ connectors on the front pane l.
MX410/MX412 System Manual Drop and Insert Applica tion 61189500L1-1B PRELIMINARY 3-9 Figure 3-9 shows the Quick Setup menu af ter DS0s 23-24 have been dropped from DS 1 1 to PPP1 and PPP 2 has been insert ed into DS0s 23-24 in DS1 2.
Drop and Insert Application MX410/MX412 System Manual 3-10 PRELIMINARY 61189500L1-1B Figure 3-11 shows the Cross-Connect Mapping menu after DS0s 1- 12 are continued throu gh from DS1 1 to DS1 2 and DS0s 13-23 are dr opped from DS1 1 to DS1 3. Figure 3-11.
MX410/MX412 System Manual Drop and Insert Applica tion 61189500L1-1B PRELIMINARY 3-11 Figure 3-13 the Cross-Co nnect Mapping menu aft er DS0s 13-23 are inserted in DS1 2 from DS1 4.
Integrated Wireless Access Device or DS0 Grooming MX410/MX412 System Manual 3-12 PRELIMINARY 61189500L1-1B Inte g r ated W ireless Access Device or DS0 Grooming The following applies to Remote Si te #1 shown in Figure 3-14 an d Figure 3-15 .
MX410/MX412 System Manual Integrated Wi reless Access Device or DS0 Grooming 61189500L1-1B PRELIMINARY 3-13 Figure 3-15. Bandwidth Efficiency with DS0 Grooming Diagram The equipment needed for an Integrated Wirele ss Access Dev ice or Bandwidth Efficiency with DS0 Grooming application is shown in Table 3-3 .
Integrated Wireless Access Device or DS0 Grooming MX410/MX412 System Manual 3-14 PRELIMINARY 61189500L1-1B Setup Connect the DS1 from which the DS0s will be dropped to the DS1 1 RJ. Connect th e other DS1s to DS1 2, 3 and 4 RJ. For more in formation, refer to “DS1 Ports” on page 4-6.
MX410/MX412 System Manual Integrated Wi reless Access Device or DS0 Grooming 61189500L1-1B PRELIMINARY 3-15 Figure 3-17 shows the Quick Setup men u after DS0s 23-2 4 have been dropped fr om DS1 1 to PPP1, and PPP 2 , 3, and 4 have been inserte d into DS0s 23-24 in DS1 2, 3 and 4 r espectively.
Integrated Wireless Access Device or DS0 Grooming MX410/MX412 System Manual 3-16 PRELIMINARY 61189500L1-1B Figure 3-19 shows the Cross-Connect Mapping menu after DS0s 1-7 are mapped from DS1 1 to DS1 2, DS0s 8-15 are mapped fr om DS1 1 to DS1 3, and DS0s 15-22 are mapped fr om DS1 1 to DS1 4.
MX410/MX412 System Manual Integrated Wi reless Access Device or DS0 Grooming 61189500L1-1B PRELIMINARY 3-17 Figure 3-21 shows the Cross-Connect Mapping menu for DS1 3. Figure 3-21. Integrated Wireless Access Device Cross-Co nnect Map Example 4 Figure 3-22 shows the Cross-Connect Mapping menu for DS1 4.
Remote Management of Other Systems using Terminal Server Ports and Ethernet Connectivity MX410/MX412 Syste m Manual 3-18 PRELIMINARY 61189500L1-1B R emote Management of Other Systems using T er m inal.
MX410/MX412 System Manual Re mote Manage ment of Other Syste ms using Terminal Server Ports and Ethern et Connectivity 61189500L1-1B PRELIMINARY 3-19 Setup First, connect the RS-232 craf t port on the other equipment to the MX410 terminal server port.
Remote Management of Other Systems using Terminal Server Ports and Ethernet Connectivity MX410/MX412 Syste m Manual 3-20 PRELIMINARY 61189500L1-1B This page is intentionally blank.
61189500L1-1B PRELIMINARY 4-1 Section 4 Installa tion GENER AL The first three tasks for installing and operating the MX410/MX412 are to unpack, inspect, and install.
Rackmount MX410/MX412 System Manual 4-2 PRELIMINARY 61189500L1-1B RACKMOUNT For a rackmount installation, perform the followin g steps: 1. Ensure the mounting b rackets to the MX 410/MX412 are attached using the two screws provided for each bracket.
MX410/MX412 System Manual Rear Pane l 61189500L1-1B PRELIMINARY 4-3 R EAR P ANEL The MX410/MX412 rear panel is equipped with wire-wrap pins for external auxi liary inputs, wire-wrap pins f or alarms (crit ical, major, and minor), a frame ground lug, and a single power connector for both DC power feeds (A and B).
Rear Pane l MX410/MX412 System Manual 4-4 PRELIMINARY 61189500L1-1B Alar m Contacts/A UX Inputs The alarm contacts and auxiliary (AUX) inputs are shown in Figure 4-4 . Figure 4-4. Alarm Contacts and AUX Inputs The alarm interfaces connect to the nine Form C type relays on the MX410/MX412 labeled CRIT , MAJOR , and MINOR .
MX410/MX412 System Manual Front Pane l 61189500L1-1B PRELIMINARY 4-5 FR O N T P A N E L The front panel s for the MX410 an d MX412 are described below. MX410 The MX410 front panel (see Figure 4-5 ) is equipped with the following: • One V.35 Port (refer to “V.
Front Panel MX410/MX412 System Manual 4-6 PRELIMINARY 61189500L1-1B V. 3 5 P o r t The V.35 port is a Nx6 4k serial interface (up to 1.536 Mbps) w ith a CCITT V.35, 34-pin connector. The V. 35 connector pin list is shown in Table 4-2 . DS1 P o r ts The DS1 interfaces located on the front pane l of the MX410/MX412 are RJ-48 connectors.
MX410/MX412 System Manual Front Pane l 61189500L1-1B PRELIMINARY 4-7 Ether net P or ts The four Ethernet jacks labeled ETHERNET located on the MX410/MX412 front panel provide LAN access to the Network. From these ports, devices located on the local area network can be remotely managed.
Front Panel MX410/MX412 System Manual 4-8 PRELIMINARY 61189500L1-1B T er minal Ser v er P o r ts The four Terminal Ser ver port RS-232 interfaces located on the fr ont panel are used to remotely connect to RS -232 managed devices .
MX410/MX412 System Manual Front Pane l 61189500L1-1B PRELIMINARY 4-9 FXS P or t The FXS port (MX412 only ) provides a 2-wir e analog interface between a Voice Frequency (VF) transmission and a signaling facility.
Front Panel MX410/MX412 System Manual 4-10 PRELIMINARY 61189500L1-1B LED Indicators The LEDs on the fr ont panel of the MX410 /MX412 indicate the stat us of the power, DS1, Ethernet, and alarm interfaces. See Table 4-7 for a listing of the LEDs and their indications.
MX410/MX412 System Manual Turn-up 61189500L1-1B PRELIMINARY 4-11 TU R N - U P The following sections provide tu rn-up steps for applying power and logging in to the MX410/ MX412. Pow e r U p To power up the MX410/MX412, perf orm the following steps: 1.
Turn-up MX410/MX412 Syste m Manual 4-12 PRELIMINARY 61189500L1-1B 3. Install the power connector for DC power feeds A and B by connecting RET A , PWR A , RET B , and PWR B to the power connector. PWR refers to respe ctive –48 VDC or ±24 VDC power sources, while RET refers to respective returns.
61189500L1-1B PRELIMINARY 5-1 Section 5 User Interface INTRODUCTION This section provid es detailed information on the following: • “System Management” on page 5-1 • “Logging in to the MX410.
Logging in to the MX410/MX 412 MX410/MX412 System Manual 5-2 PRELIMINARY 61189500L1-1B – no parity (none) –o n e s t o p b i t – no flow control 2. Set the PC for direct connect on the appropriate communications port (as opp osed to dial up connection).
MX410/MX412 System Manual Menu Structure 61189500L1-1B PRELIMINARY 5-3 MENU STR UCTUR E The menu structu re for the M X410/MX412 is a layered menu tree. Ea ch layer of the menu tree is displayed as a menu or a screen. Th is section defines the terminology used in conjunction with the MX410/MX412 menu system.
Menu Layout and Navigation MX410/MX412 System Manual 5-4 PRELIMINARY 61189500L1-1B MENU LAYOUT AND NA VIGATION Figure 5-1 illustrates the basic menu layout used in the MX410/MX412 menu system. The MX410/MX412 Menu Layout figure is general in nature, and not all menus contain all of the elements shown in the figure.
MX410/MX412 System Manual Menu Tree 61189500L1-1B PRELIMINARY 5-5 Table 5-1 shows the general keyboard comm ands for the MX410/MX41 2. MENU T R EE Menu trees are maps that can be used to lo c ate provisioning options with ease. This subsection provides a detailed set of menu tr ees for the MX410/MX412.
Menu Tree MX410/MX412 System Manual 5-6 PRELIMINARY 61189500L1-1B Figure 5-2. MX410/MX412 Menu Tree Unit Name CLEI Code Part Number Serial Number Product Revision MAC Address Code V ersion Code Checksum Boot V ersion Boot Checksum 2. Provisioning Main Menu 1.
MX410/MX412 System Manual Menu Tree 61189500L1-1B PRELIMINARY 5-7 Figure 5-2. MX410/MX412 Menu Tree (Continued) 5. General 1. 9600 2. 19200 3. 38400 4. 57600 5. 1 15200 2. Create New User Account 1. User ID 2. Password 3. Apply 4. Access T ech Support Account Challenge Key Enter Response Key 1.
Menu Tree MX410/MX412 System Manual 5-8 PRELIMINARY 61189500L1-1B Figure 5-2. MX410/MX412 Menu Tree (Continued) 1. Trap Host IP 2. Trap Host Method 3. Trap Host Status 7. SNMP 8. System Configuration Archive (SCA) 9. Save Provisioning 10. Auto Save 1.
MX410/MX412 System Manual Menu Tree 61189500L1-1B PRELIMINARY 5-9 Figure 5-2. MX410/MX412 Menu Tree (Continued) 1. PPPs 2. V .35 4. IP Address / Subnet Mask 3. System ID New System Name 3. FXS (MX412 Only) 5. Default Gateway New Gateway 6. Date Enter Date (MM/DD/YYYY) 7.
Menu Tree MX410/MX412 System Manual 5-10 PRELIMINARY 61189500L1-1B Figure 5-3. MX410/MX412 Menu Tree (Continued) 1. Aux #1 Input 2. Aux #2 Input 3. Aux #3 Input 4. Aux #4 Input 5. Power Feed A 6. Power Feed B 7. PSU A (MX410 Only) 8. PSU B (MX410 Only) 2.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-11 MENU DESCRIPTIONS The MX410/MX412 Main Menu (see Figure 5-4 ) is the access point to all other operations. Each Main menu item has several functions and submenus that identify and provide access to specific operations and parameters.
Menu Descriptions MX410/MX412 System Manual 5-12 PRELIMINARY 61189500L1-1B Configur ation Screen The Configuration Screen (see Figure 5-5 ) displays informatio n about the MX410/MX412. Information su ch as Code Version ch anges as upgrade s are performed .
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-13 T able 5-3. MX410/MX412 Configuration Scr een Fields Field Description Unit Name This field displays the MX410/M X412 unit name. CLEI Code This field displays the Common Language Equipment Identifier (CLEI) code of the MX410/MX412.
Menu Descriptions MX410/MX412 System Manual 5-14 PRELIMINARY 61189500L1-1B Pr o visioning Menu The Provisioning Menu (see Figure 5-6 ) is used to make provisioning changes to various options. Figure 5-6. Provisioning Menu The Provisioning menu opti ons are shown in Table 5-4 .
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-15 T able 5 -4. Provisioning Menu Options Option Description Function 1 DS1 Ports This option displays the “DS1 Ports Menu” on p age 5-16. 2 V.35 Port This option displays the “V.
Menu Descriptions MX410/MX412 System Manual 5-16 PRELIMINARY 61189500L1-1B DS1 P or ts Menu The DS1 Ports Menu (see Figure 5-7 ) displays line length, line co ding, loopback det ection, framing, SNMP .
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-17 The DS1 Ports menu options are shown in Table 5-5 . T able 5-5. DS1 Por ts Menu Options Option Description Fu nction 1 DS1 Port #1 This option displays the “DS1 Provisioning Menu” on page 5- 18.
Menu Descriptions MX410/MX412 System Manual 5-18 PRELIMINARY 61189500L1-1B DS1 Pro visioning Menu The DS1 Provisioning menu (see Figure 5-9 ) is used to set the line length, line coding, loopback detection, framing, SNMP line status trap, SNMP link status t rap, circuit ID, interface state, and alarm pass thru information for the selected DS1 port.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-19 Alarm Pass Thru T able 5-6. DS1 Provisioning Menu Options Option Description Function 1 Line Length This option sets the line length (lin e build out) for each port inter- face according to the distance fr om the MX410/MX412 to the other device.
Menu Descriptions MX410/MX412 System Manual 5-20 PRELIMINARY 61189500L1-1B Primar y Timing Mode Menu The Primary Timing Mode menu (see Figure 5-10 ) is used to set the primary timing mode for the selected DS1 port (1-4 on the MX410 and 1-12 on the MX41 2).
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-21 Secondar y Timing Mode Menu The Secondary Timing Mode menu (see Figure 5-11 ) is used to set the secondary timing mode for the selected DS1 p ort (1-4 on the MX4 10 and 1-12 on the MX412).
Menu Descriptions MX410/MX412 System Manual 5-22 PRELIMINARY 61189500L1-1B V .35 Por t Me nu The V.35 Port Menu (see Figure 5-12 ) is used to provision the V.35 Port. Figure 5-12. V.35 Port Menu The V.35 Port menu options are shown in Table 5-9 . T able 5-9.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-23 Cross-Con nect Ma pping Menu The Cross-Connect Mapping menu is used to di splay DS0 information for the four DS1 ports (12 ports on the MX412), as well as FXS (MX412 only), PPP, and V.
Menu Descriptions MX410/MX412 System Manual 5-24 PRELIMINARY 61189500L1-1B The Cross-Connect Mapping menu options are shown in Table 5-10 . T able 5-10.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-25 T er minal Ser v er P or ts Menu The Terminal Server Ports Menu (see Figure 5-15 ) is used to select Terminal Port 1 through Port 4 for provisio ning. Figure 5-15. Terminal Server Ports Menu The Terminal Server Ports menu options are shown in Table 5-11 .
Menu Descriptions MX410/MX412 System Manual 5-26 PRELIMINARY 61189500L1-1B T er minal Ser v er P or t (1 - 4) Menu The Terminal Server Port Menu (see Figure 5-16 ) is used to provision the Terminal Sever Port selected on the (previous) Terminal Server Ports menu.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-27 General Pr o visioning Menu The General Provisioning Menu (see Figure 5-17 ) is used to provision th e craft port Baud rate, the date, time, system ID, auto-logoff inactivi ty time, to reset the MX410/MX412, and to handle security administration.
Menu Descriptions MX410/MX412 System Manual 5-28 PRELIMINARY 61189500L1-1B 5 Auto-Logoff Inactivity Time This option defines when a menu session automatically termi- nates due to inactivity.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-29 Network Mana geme nt Menu The Network Management menu (see Figure 5-18 ) is used to provisio n network information. Figure 5-18. Network Management Menu The Network Management menu options are shown in Table 5-14 .
Menu Descriptions MX410/MX412 System Manual 5-30 PRELIMINARY 61189500L1-1B Ether net Menu The Ethernet Menu (see Figure 5-19 ) is used to provision Ethernet information. Figure 5-19. Ethernet Menu The Ethernet menu options are shown in Table 5-15 . T able 5-1 5.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-31 MAC Address This read-only field displays the Medium Access Control (MAC) Address. MAC Addresses are loca tion-independent (programmed into the card at manufacture, they relocate when the card does).
Menu Descriptions MX410/MX412 System Manual 5-32 PRELIMINARY 61189500L1-1B PPP BCP/IPCP Menu Point-to-Point Protocol (PPP) is commonly us ed for LAN extens ion an d Remote management connectivity.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-33 T able 5-1 6. PPP BCP/IPCP Menu Options Option Description Function 1 BCP/IPCP This option is used to select eith er BCP (Brid ge Cont rol Protocol) or IPCP (IP Control Protocol for routing).
Menu Descriptions MX410/MX412 System Manual 5-34 PRELIMINARY 61189500L1-1B DHCP Ser v er Menu The DHCP (Dynamic Host Configuration Protocol) Server menu shown in Figure 5-21 , is used to provision DHCP server connections. Figure 5-21. DHCP Server Menu The DHCP Server menu options are shown in Table 5-17 .
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-35 SNMP Menu The SNMP (Simple Network Mana gement Protocol) menu (see Figure 5-22 ) is used to provision SNMP information. Figure 5-22. SNMP Menu The SNMP menu options are shown in Table 5-18 .
Menu Descriptions MX410/MX412 System Manual 5-36 PRELIMINARY 61189500L1-1B 5 Trap Host 4 IP This option invokes another menu which is used to enter the Trap Host 4 IP ad dress of an SNMP manager to which the MX410/ MX412 sends traps , the method (v ersion 1 traps or version 2 notif i- cations), and enable or disable the trap host.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-37 SCA Update Menu The SCA (System Configuration Archive) Up date Menu (see Figure 5 -23 ) is used to update SCA information. Figure 5-23. SCA Update Menu The SCA Update menu options are shown in Table 5-19 .
Menu Descriptions MX410/MX412 System Manual 5-38 PRELIMINARY 61189500L1-1B Quick Setup Menu To simplify the installation process, all of th e basic configuration op tions necessary to setup the MX410/MX412 are grouped together on the Quick Setup menu (see Figure 5-24 ).
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-39 3 FXS (MX412 only) This option is used to provis ion the FXS port. Options are as follows: • Choose TO Gro up (for DS1 1 thro ugh DS1 4) • Choose TO DS0 Ra nge: enter a range • Mo d e: Se l ec t L o op St a rt, P LA R D4 , P L AR D3 , or F X R in gd o wn .
Menu Descriptions MX410/MX412 System Manual 5-40 PRELIMINARY 61189500L1-1B Status Screen The Status screen (see Figure 5-25 ) provides detailed status informat ion about th e DS1 Ports, Ethernet Ports, PPP, Timing, and the Power Feed. Figure 5-25. Status Screen The Status menu options are shown in Table 5-21 .
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-41 Test This field displays one of the following possible states: • Data Mode: Indicates no tests are active • Payload Loopb.
Menu Descriptions MX410/MX412 System Manual 5-42 PRELIMINARY 61189500L1-1B T est Menu The Test menu (see Figure 5-26 ) provides options for testing the DS1 Ports.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-43 DS1 (P or t #) Menu The DS1 (Port #) menu (see Figure 5-27 ) provides options for testing the DS1 Ports. Figure 5-27. DS1 (Port #) Menu The DS1 (Port #) menu o ptions are shown in Table 5 -23 .
Menu Descriptions MX410/MX412 System Manual 5-44 PRELIMINARY 61189500L1-1B P or t (#) T est M enu The Port (#) Test menu (see Figure 5-28 ) provides options for testing the DS1 Port s. Figure 5-28. Port (#) Test Menu The Port (#1-#4 on MX410, and #1 -#12 on MX412) Test menu options are shown in Table 5- 24 .
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-45 DS1 T est Pa tter n Menu The DS1 Test Pattern menu (see Figure 5-29 ) provides options for testing the DS1 ports using pattern data. Figure 5-29. DS1 Test Pattern Menu The DS1 Test Pattern menu options are all test patt ern types.
Menu Descriptions MX410/MX412 System Manual 5-46 PRELIMINARY 61189500L1-1B P erfor mance Monitoring Menu The Performance Monitoring menu (see Figure 5-30 ) provides options for viewing performance data affecting the MX410/MX4 12 operations. Data is viewed in daily or 15-minute increments.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-47 1. FE ( Frame bit E rror): This parame ter indicates the occurrence of a frame bit error in the received frame bi t pattern. 2. CS (Controlled Slip): This parameter indicates the replication or deletion of the 192 payload bits of a DS1 frame by the receivin g unit.
Menu Descriptions MX410/MX412 System Manual 5-48 PRELIMINARY 61189500L1-1B Daily Perfor mance Mon itoring Scr een The Daily Performance Monitoring screen (see Figure 5-31 ) displays DS1 performance monitoring data in daily increm ents and in a tabular form at.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-49 Daily PM T hresholds Menu The Daily PM Thresholds menu (see Figure 5-33 ) displays DS1 pe rformance monitoring thresholds data in a tabular f ormat.
Menu Descriptions MX410/MX412 System Manual 5-50 PRELIMINARY 61189500L1-1B 8 UAS-P This option sets the UAS-P threshold value. The available threshold range is (1-65535) . The default value is 10. 9 Restore ALL DS1 Threshold Defaults This option restores all threshold values to the defaults listed above.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-51 Quar ter Hour PM T hresh olds Menu The Quarter Hour PM Thresholds menu (see Figure 5-34 ) displays DS1 performance monitoring thresho lds data in a tabular f ormat.
Menu Descriptions MX410/MX412 System Manual 5-52 PRELIMINARY 61189500L1-1B Clear PM Data Menu This option invokes the Cle ar Performance Mo nitoring Data menu and requests verification before deleting all previously colle ct ed performance monito ring data.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-53 System Alar ms Menu The System Alarms Menu (see Figure 5-35 ) provides options for viewing all alarms affecting MX410/MX412 system operations . Alarms may be viewed within the Master Log menu (detailed in the next section).
Menu Descriptions MX410/MX412 System Manual 5-54 PRELIMINARY 61189500L1-1B Master Log Menu The Master Log Menu (see Figure 5-36 ) is used to review and acknowledge alarms.
MX410/MX412 System Manual Menu Descriptions 61189500L1-1B PRELIMINARY 5-55 Code Download Method Menu The Code Download Method menu (see Figure 5-37 ) provides options for upgrading the software of the MX41 0/MX412. Figure 5-37. Code Download Method Menu The Code Download Method menu options are sh own in Table 5-29 .
Menu Descriptions MX410/MX412 System Manual 5-56 PRELIMINARY 61189500L1-1B This page is intentionally blank..
61189500L1-1B PRELIMINARY A-1 A ppendix A W ar r anty W AR RANTY AND CUSTOMER SER VICE ADTRAN will replace or repair this product within the warranty period if it does not me et its published specifications or fails while in se rvice. Warr anty information can be found at www.
Carrier Networks Division 901 Explorer Blvd. Huntsville, AL 3580 6 ®.
An important point after buying a device ADTRAN MX412 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ADTRAN MX412 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ADTRAN MX412 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ADTRAN MX412 you will learn all the available features of the product, as well as information on its operation. The information that you get ADTRAN MX412 will certainly help you make a decision on the purchase.
If you already are a holder of ADTRAN MX412, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ADTRAN MX412.
However, one of the most important roles played by the user manual is to help in solving problems with ADTRAN MX412. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ADTRAN MX412 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center