STACKABLE TOKEN RING
INTELLIGENT HUBS
USER’S GUIDE

Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
Printed in the United States of America
MicroMMAC-22T, 24T, 42T, 44T, BRIM, and TPIM are trademarks of Cabletron Systems, Inc.
SPECTRUM, LANVIEW, and Remote LANVIEW are registered trademarks of Cabletron Systems, Inc.
IBM is a registered trademark of International Business Machines Corporation.
DEC, VT200, and VT300 are trademarks of Digital Equipment Corporation.
CompuServe is a trademark of Compuserve, Inc.
Printed On Recycled Paper
All Rights Reserved

FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas.
Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.
Read the instructions for correct handling.

CABLETRON SYSTEMS, INC. PROGRAM
LICENSE AGREEMENT
This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.
OF LIABILITY
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABLITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.

2. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR ON THE DURATION OR LIMITATION OF IMPLIED WARRANTEES IN SOME INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.
RIGHTS
The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at 252.227-7013. Cabletron Systems, Inc., 35 Industrial Way. Rochester, New Hampshire 03866


INTRODUCTION
Welcome to the Cabletron Systems MicroMMAC-22T/-24T/-42T/ -44T Stackable Token Ring Intelligent Hub User’s Guide. This manual provides installation instructions, network requirements, reference information, and operating instructions for the MicroMMAC-T (Figure 1-1) family of stackable hubs. Installing the MicroMMAC-T requires familiarity with the physical layer components of Token Ring (IEEE 802.5) data communications networks.
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM UTP CABLE MicroMMAC-24T
18 17 16 15 14 13 24 23 22 21 20 19
CPU ACT MGMT 16 Mb/s COM 1 COM 2
16M 4M TPIM
DISPLAY SPEED
RESET
RO
6 5 4 3 2 1
Figure 1-1. The MicroMMAC-T
This manual contains the following information:
Chapter 1, Introduction, outlines the contents of this manual and describes features of the MicroMMAC-T and its add-on components. It also lists sources where more information on Token Ring network implementation can be found.
Chapter 2, Requirements/Specifications, describes cabling requirements, network guidelines, and MicroMMAC-T operating specifications.
Chapter 3, Installation, contains MicroMMAC-T installation instructions and discusses network connections using various media types. This chapter includes instructions for setting the Ring Speed Switch, the Reset Switch, the NVRAM Switch, and the TPIM Phantom Switch. It also
Slot Ring Out

describes how to install a TPIM and concludes with installation check-out instructions.
Chapter 4, Local Management, explains how to set up and use a management terminal and a modem to access Local Management.
Chapter 5, Troubleshooting, explains how to monitor the operation performance of the MicroMMAC-T using LANVIEW® LEDs and LCD’s. It also explains how to access POWER UP diagnostic test information.
The MicroMMAC-T is an intelligent, stackable Multi-Media Access Center providing connectivity and SNMP management for up to 255 Token Ring users (Local Management for up to 120 Token Ring users) in remote office environments. The MicroMMAC-T can be used in conjunction with Cabletron’s STH HubSTACK series of stackable non-intelligent hubs.
Figure 1-2 illustrates a typical MicroMMAC-T configuration scenario. Attachable Bridge/Routing Interface Modules (BRIMs), incorporated as seamless entities within the MicroMMAC-T, provide connectivity not only to standard Token Rings but also to Ethernet, FDDI, ATM, and WAN environments, depending upon the BRIM types used.
Token Ring Port Interface Modules (TPIMs) attachable at the Ring In/Ring Out (RI/RO) ports provide connectivity and expanded trunk connections to a range of Token Ring media: Unshielded Twisted Pair (UTP), Shielded Twisted Pair (STP), and Fiber.
By installing Cabletron’s MicroSNAC daughterboard in the MicroMMAC-T, you can consolidate SNA/SDLC, BSC, LAN, and WAN connectivity into a single unit.
Telnet support provides easy access to Local Management tools from any TCP/IP based node on the network.
The MicroMMAC-T complies with the IEEE 802.5 standard and is fully IBM Token Ring compatible. The remainder of this chapter discusses MicroMMAC-T features in greater detail.

SDLC TOKEN RING
UTP
WORKSTATION
Figure 1-2. Typical MicroMMAC-T Configuration Scenario
All MicroMMAC-Ts are functionally and physically identical except for the number and type of their Trunk Connection Unit (TCU) lobe ports. The following MicroMMAC-T configurations are available:
Telnet

The active TCU ports regenerate, reshape, and filter the incoming signal, permitting UTP lobe cable lengths of up to 120 meters and STP lobe cable lengths up to 150 meters at 16 Mbps ring speed. The MicroMMAC-22T and the MicroMMAC-42T can be upgraded in the field using the Cabletron UTP and STP 12-port upgrade kits.
Differential Manchester encoding is used for each concentrator module TCU port. This permits passing data regardless of receive link polarity.
If a station attempts to insert into a ring port at a different speed from the one set on the MicroMMAC-T, that port is automatically bypassed to prevent the ring from beaconing. The Lobe Port Status LED blinks red (for more information, see Section 5.1, USING LANVIEW LEDs) to indicate that the port with the speed fault is being bypassed.
Local Management provides you with the ability to manage the MicroMMAC-T and all of its attached segments, including most BRIMs and the MicroSNAC device. The CR BRIM-W/T and the MicroSNAC provide their own configuration firmware.
Access Local Management by connecting an actual or emulated Digital Equipment Corporation VT100™ series terminal to the MicroMMAC-T’s COM 1 port or the COM 2 port. To view diagnostic test information from a display terminal, use the COM 2 port.
Token Ring Port Interface Modules (TPIMs)
TPIMs are modular connector cards used for expanding trunk connections to a range of Token Ring media. TPIMs have embedded repeaters that
Active TCU Ports · Cable Signal Polarity · Speed Fault Protection

re-time all data. Cabletron offers a variety of TPIMs for RI/RO trunk connections as shown in Table 1-1.
Table 1-1. TPIMs
TPIM Media Type Connector
TPIM-T1 Shielded Twisted Pair DB9
TPIM-T2 Unshielded Twisted Pair RJ45
TPIM-T4 Shielded Twisted Pair RJ45
TPIM-F2 Multimode Fiber Optic ST
TPIM-F3 Single mode Fiber Optic ST
Use the Ring Speed Switch to select either 4 or 16 Mbps ring speed.
The firmware image on the MicroMMAC-T can be upgraded by Flash EEPROM downloads via Cabletron System’s Remote LANVIEW/Windows version 2.3 or later, or via any server supporting BOOTP or TFTP protocols.
Cabletron Systems’ LANVIEW LEDs, located on the face of the MicroMMAC-T, provide an effective monitoring and troubleshooting tool to help diagnose power failures, RI/RO status, cable faults, ring speed, link problems, and network activity. See Section 5.1 for information about using LEDs.
Cabletron’s Distributed LAN Monitor Mode
To manage a network that includes multiple subnets, remote network management stations need to query multiple management devices, increasing the data traffic on the network. Network managers can reduce the amount of management related traffic by setting the MicroMMAC-T into Distributed LAN Monitor mode via a remote management package. The MicroMMAC-T in DLM mode will collect management data from the
Ring Speed Switch · Flash EEPROM · LANVIEW LEDs

numerous management devices and serve as their management data representative. The network management station then has to query only one management device, the MicroMMAC-T in DLM mode, to access management data for all management devices on the network.
Consult your network manager for DLM setup.
Both of the front panel COM ports are factory-configured to support Local Management connections. Select among configuration options for Local Management, Uninterruptible Power Supplies (UPS), the Serial Line Internet Protocol (SLIP), and modems.
LCD and LCD Display Button
MicroMMAC-T’s front panel LCD used in conjunction with the LCD display button provides you with comprehensive system-level information such as power-up diagnostics, FLASH image revision levels, IP addresses, and error alerts. See Section 5.2 for more information.
The Reset button on the front panel initializes the processor when pressed. The information contained in NVRAM is retained after initialization. See Section 3.5 for more information.
The MicroMMAC-T provides access to the following Management Information Bases:

The MicroMMAC-T supports the RMON MIB RFC 1271/1513 Token Ring Extensions shown in Table 1-2.
Table 1-2. RMON MIB RFC 1271/1513 Support
Token Ring ML Stats Table
Token Ring P Stats Table
Token Ring ML History Table
Token Ring P History Table
Alarm Table alarm 1

Table 1-2. RMON MIB RFC 1271/1513 Support (Cont.)
Ring Station Control Table
Ring Station Order Table
Ring Station Config Control Table
Ring Station Config Table
Source Routing Stats Table
The MicroMMAC-T can be stacked with up to four HubSTACK STH series non-intelligent hubs as shown in Figure 1-3. Four connectors are available on the back panel of the MicroMMAC-T for connecting STH 12/24 type non-intelligent hubs. The MicroMMAC-T provides complete management, including full packet and error statistics for the entire stack, individual device, or individual port.
It is not necessary to power-off the MicroMMAC-T to add or remove hubs from the stack.


A slot on the back panel of the unit provides installation access for BRIMs to the hub. MicroMMAC-T management systems treat the installed BRIM and the hub as a single entity. Cabletron offers the BRIMs listed in Table 1-3.

Table 1-3. BRIMs
BRIM-W6 Wide Area Network (Full or Fractional T1; 56k DDS)
BRIM-A6 Asynchronous Transfer Mode Connection
BRIM-T6 Token Ring Connection
CR BRIM-W/T Cisco WAN BRIM for Token Ring
BRIM-FO Fiber Distributed Data Interface Connection
The MicroSNAC add-on daughterboard provides two ports, both of which can be used to provide conversion from SNA/SDLC or BSC links to LLC2. The MicroSNAC can operate in a converter mode or as a WAN concentrator.
The MicroMMAC-T may be managed through any Simple Network Management Protocol (SNMP) software. Cabletron Systems offers the following remote management packages:
The MicroMMAC -T supports Telnet, which allows any TCP/IP based node on the network to establish a Local Management session with the
BRIM Description · BRIM-E6 Ethernet Connection

module. This feature complements the remote SNMP management and allows for quick hub configuration changes or checks.
The following publications provide more information on Token Ring network implementation.
Local Area Networks, Token Ring Access Method, IEEE Standard 802.5 (1989)
Commercial Building Wiring Standard, EIA/TIA-568
LAN Troubleshooting Handbook, Mark Miller (1989, M&T Publishing)
For additional support related to the Cabletron Systems MicroMMAC-T, or for any questions, comments, or suggestions concerning this manual, contact Cabletron Systems Technical Support:
By phone (603) 332-9400
Monday-Friday; 8am - 8pm EST
By CompuServe® GO CTRON from any ! prompt
By Internet mail support@ctron.com
By BBS (603) 337-3750
By mail Cabletron Systems, Inc.
P.O. Box 5005 Rochester, NH 03866-5005

REQUIREMENTS/SPECIFICATIONS
Read this chapter prior to installing the MicroMMAC-T. It contains operating specifications and requirements for power and cabling. To obtain satisfactory performance from this equipment, networks must meet the requirements and conditions specified in this chapter. Failure to follow these guidelines may result in poor network performance.
Token Ring architecture provides for a set of Trunk Coupling Units (TCUs) connected by trunk cabling. To extend the trunk cabling, install TPIMs into the MicroMMAC-T’s RI/RO ports. TPIMs have embedded repeaters and provide trunk connections for UTP, STP, Multimode Fiber, and Single Mode Fiber cabling.
Attach stations to the TCU lobe ports with lobe cabling. Figure 2-1 shows a typical ports to cables configuration.
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
18 17 16 15 14 13 24 23 22 21 20 19
DISPLAY
CPU ACT MGMT 16 Mb/s COM 1 COM 2
RESET
RO
12 11 10 9 8 7
6 5 4 3 2 1
Lobe Cabling TCU Lobe Ports
Trunk Cabling Token Ring Station
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
18 17 16 15 14 13 24 23 22 21 20 19
CPU ACT MGMT 16 Mb/s COM 1 COM 2
DISPLAY SPEED
RESET
RO RI
12 11 10 9 8 7
6 5 4 3 2 1
Figure 2-1. MicroMMAC-T Ports/Cables
Ring Out TPIM · Ring In TPIM

2.1.1 UTP Cable Specifications
The MicroMMAC-22T and MicroMMAC-24T lobe ports and the TPIM-T2 support voice grade Unshielded Twisted Pair (UTP) cable, as described in specifications for EIA/TIA TSB 568 and IBM Type 3 cable.
UTP consists of four pairs of 24 AWG solid wire for data or voice communication and is typically used to wire cable runs within building walls. In some installations, existing UTP building wiring can be used for Token Ring cabling. UTP cable must conform to the limits shown in Table 2-1.
The increased popularity and cost advantages of UTP cable have driven refinements in UTP cable design. Better grades of UTP cable, known as supergrade or level 4, provide improved transmission characteristics and may allow operation at 16 Mbps on longer lobe cables.
The values listed in Figure 2-1 include the maximum attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the segment.
Table 2-1. UTP Voice Grade and Category 3 Specifications
1 MHz 100Ω ±15%
4 MHz 100Ω ±15%
10 MHz 100Ω ±15%
16 MHz 100Ω ±15%
Attenuation and Impedance · Frequency Impedance Attenuation

Lobe length is the physical length of the cable connecting a station to its TCU port at the MicroMMAC-T. Table 2-2 lists the maximum lobe cable length for ring speeds of 4 and 16 Mbps. The values listed refer to total lengths made up of UTP cable only.
Table 2-2. UTP Maximum Lobe Lengths
UTP Cable Type Maximum Lobe Length
4 Mbps 16 Mbps
Category 3 200 meters 100 meters
(656 feet) (328 feet)
Category 4 200 meters 100 meters
(656 feet) (328 feet)
Category 5 250 meters 120 meters
(820 feet) (394 feet)
Type 3 Media Filters
A Type 3 Media Filter is required when connecting a UTP lobe segment from a MicroMMAC-22T or MicroMMAC-24T to a station supporting STP cabling. Cabletron Systems offers the following Type 3 Media Filters:
Maximum Number of Stations
When UTP lobe cabling is used in any ring segment, the number of ring stations supported by the MicroMMAC-T is limited to 150, regardless of the operating ring speed.
Maximum Lobe Lengths

2.1.2 STP Cable Specifications
MicroMMACs 42T and 44T and TPIMs T1 and T4 support IBM Type 1, 2, 6, and 9 STP cabling as described below:
The attenuation values shown in Table 2-3 include the attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the segment
Table 2-3. STP Cable Specifications
Types Frequency Impedance Attenuation
1 & 2 4 MHz
6 & 9 4 MHz
The lobe length is the physical length of the cable connecting a station to its TCU port at the MicroMMAC-T. Table 2-4 lists the maximum lobe

cable length for ring speeds of 4 and 16 Mbps. The cable lengths listed in Table 2-4 refer to total lengths made up of STP cable only
Table 2-4. STP Maximum Lobe Lengths
STP Cable Type Ring Speed
4 Mbps 16 Mbps
IBM Types 1 & 2 300 meters 150 meters
(984 feet) (492 feet)
IBM Types 6 & 9 (only for station to wall jack and patch panels)
30 meters 30 meters
(99 feet) (99 feet)
The maximum trunk cable length between the MicroMMAC-T and other active devices is equal to the maximum drive distance as shown in Table 2-5. For passive devices, the combined length of twice the longest trunk cable, plus the longest lobe cable attached to the passive ring segment cannot exceed the Maximum Drive Distance.
Table 2-5. STP Maximum Drive Distance
STP Cable Type Ring Speed
4 Mbps 16 Mbps
IBM Types 1 & 2 770 meters 346 meters
(2525 feet) (1138 feet)
IBM Types 6 & 9 513 meters 230 meters
(1683 feet) (755 feet)
Maximum Number of Stations
If only STP lobe cabling is used throughout the ring, the MicroMMAC-T supports up to 255 ring stations, regardless of ring speed.
Maximum Trunk Lengths

If multiple cable types exist in network, compensations must be made for the different cable attenuations. Type 6 and Type 9 cables can run only 2/3 the distance of Type 1. Therefore 10 meters of Type 1 ≈ 6.6 meters of Types 6 and 9.
2.1.3 Multimode Fiber Optic Cable Specifications
Table 2-6 shows specifications for the Multimode Fiber Optic Cable supported by TPIM-F2
Table 2-6. Multimode Fiber Optic Cable Specifications
Cable Type Attenuation Maximum Drive Distance
50/125 µm 13.0 dB or less The maximum allowable fiber optic cable length is 2 km (2187.2 yards). However, IEEE 802.5 specifications allow for a maximum of 1 km (1093.6 yards).
62.5/125 µm 16.0 dB or less
100/140 µm 19.0 dB or less
The maximum trunk cable length between the MicroMMAC-T and other active devices is equal to the maximum drive distance as shown in Table 2-6. For passive devices, the combined length of twice the longest trunk cable, plus the longest lobe cable attached to the passive ring segment, must not exceed the Maximum Drive Distance Trunk Length.
Fiber optic cable must be tested with an attenuation test set adjusted for an 850 nm wavelength. This test ensures that a cable’s signal loss is within acceptable limits. Table 2-6 shows the attenuation for each Multimode cable type.
Mixed Cable Types · Maximum Trunk Lengths · Attenuation

The fiber optic delay budget, which determines the fiber optic cable’s maximum length, should be calculated and taken into consideration in the network design stage. Fiber optic delay budget is determined by summing the optical signal loss due to fiber optic cable attenuation, in-line splices, and fiber optic connectors.
Table 2-7 shows specifications for the Single Mode Fiber Optic Cable supported by TPIM-F3.
Table 2-7. Single Mode Fiber Optic Cable Specifications
Cable Type Attenuation Maximum Drive Distance
8/125-12/125 µm 10.0 dB or less The max. allowable fiber optic cable length is 10 km (10936 yards). However, IEEE 802.5 specs allow for a max. of 1 km (1093.6 yards).
The maximum trunk cable length between the MicroMMAC-T and other active devices is equal to the Maximum Drive Distance as shown in Table 2-7. For passive devices, the combined length of twice the longest trunk cable plus the longest lobe cable attached to the passive ring segment must not exceed the Maximum Drive Distance Trunk Length.
Fiber optic cable must be tested with an attenuation test set adjusted for a 1300 nm wavelength. This test ensures that the cable’s signal loss is within an acceptable range of 10 dB or less for any given single mode fiber optic link.
Fiber Optic Budget · Maximum Trunk Lengths · Attenuation

The fiber optic delay budget, which determines the fiber optic cable’s maximum length, should be calculated and taken into consideration in the network design stage. Fiber optic delay budget is determined by summing the optical signal loss due to fiber optic cable attenuation, in-line splices, and fiber optic connectors.
The following sections describe common cable problems and recommendations for correcting them.
Crosstalk is interference caused by signal coupling between different cable pairs contained within a multi-pair cable bundle. Multi-pair cables should not be used for UTP lobe cabling. UTP lobe cabling should be dedicated to carrying Token Ring traffic. Avoid mixing Token Ring signals with other applications (voice, etc.) within the same cable.
Noise can be caused by crosstalk or externally imposed impulses. If noise-induced errors are suspected, ensure that the electrical wiring in the area is properly wired and grounded and/or try re-routing cabling away from potential noise sources (motors, switching equipment, fluorescent lighting, high amperage equipment).
The attenuation of PVC-insulated cable varies significantly with temperature. Check the cable manufacturer’s specifications. Plenum-rated cables are strongly recommended in areas where temperatures exceed 40˚C. Under such conditions, plenum-rated cables ensure that cable attenuation remains within specifications.

In addition to complying with the preceding cable specifications, the following recommendations should be followed to minimize errors and obtain optimum performance from the network:
The RJ45 COM 1 and COM 2 ports (Figure 2-2) support Local Management applications. A description of COM port applications is listed below:
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM UTP CABLE MicroMMAC-24T
DISPLAY RESET SPEED
COM 2 COM 1
Figure 2-2. COM 1/COM 2 Ports
Other Considerations

Both COM 1 and COM 2 ports are factory-configured to support Local Management access by an actual or emulated Digital Equipment Corporation VT 100™ terminal.
Terminal display of POWER UP booting/diagnostic tests available only when terminal is connected to COM 2 (for information about Boot sequences, see Section 5.3 ).
COM 2 supports Uninterruptible Power Supply (American Power Conversion only).
Both COM ports support Serial Line Internet Protocol (SLIP).
Both COM ports support modem connection.
TPIMs provide Ring In/Ring Out (RI/RO) connections that can extend the network through a variety of media. Each TPIM has an embedded repeater that re-times all data.
The LNK (Link) LED on each TPIM provides the following information:
TPIM-T1 provides a female DB9 connector that supports STP cabling. Figure 2-3 shows TPIM-T1 pinouts for Ring Out and Ring In applications.
Booting/Diagnostics · Modem

LNK 5 4 3 2 1
9 8 7 6
RING OUT 1. Transmit + 2. Ground 3. +5V at 250 mA 4. Ground 5. Receive - 6. Transmit - 7. Ground 8. Ground 9. Receive +
RING IN 1. Receive + 2. Ground 3. +5V at 250 mA 4. Ground 5. Transmit - 6. Receive - 7. Ground 8. Ground 9. Transmit +
Figure 2-3. TPIM-T1 Pinouts
TPIM-T2 provides an RJ45 connector that supports UTP cabling. Figure 2-4 shows pinouts for Ring Out and Ring In applications.
LNK 1 2 3 4 5 6 7 8
RING OUT 1. Not Used 2. Not Used 3. Receive - 4. Transmit + 5. Transmit - 6. Receive + 7. Not Used 8. Not Used
RING IN 1. Not Used 2. Not Used 3. Transmit - 4. Receive + 5. Receive - 6. Transmit + 7. Not Used 8. Not Used
Figure 2-4. TPIM-T2 Pinouts
TPIM-T4 is an RJ45 connector that supports STP cabling. Figure 2-5 shows pinouts for Ring Out and Ring In applications.

LNK 1 2 3 4 5 6 7 8
RING OUT 1. Not Used 2. Not Used 3. Receive - 4. Transmit + 5. Transmit - 6. Receive + 7. Not Used 8. Not Used
RING IN 1. Not Used 2. Not Used 3. Transmit - 4. Receive + 5. Receive - 6. Transmit + 7. Not Used 8. Not Used
Figure 2-5. TPIM-T4 Pinouts
TPIM-F2, shown in Figure 2-6, provides an ST connector that supports Multimode fiber Optic cabling.
TPIM-F2
Figure 2-6. TPIM-F2
NOTE: Transmitter power and receive sensitivity levels, shown in Table 2-8, are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given to those measured on any particular port. If power levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed (i.e. -30.5 dBm peak=-33.5 dBm average).

Table 2-8. TPIM-F2 Specifications.
Parameter Typical Value Worst Case Worst Case Budget
-30.5 dBm -28.0 dBm — —
-7.6 dBm -8.2 dBm — —
Transmitter Power:
50/125 µm -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB
62.5/125 µm -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB
100/140 µm -7.0 dBm -9.0 dBm 19.0 dB 23.5 dB
TPIM-F3, shown in Figure 2-7, is an ST connector that supports Single Mode fiber Optic cabling.
TPIM-F3
Figure 2-7. The TPIM-F3
Table 2-9. TPIM-F3 Specifications
Parameter Typical Minimum Maximum
Transmitter Peak Wave Length
1300 nm 1270 nm 1330 nm
Spectral Width 60 nm – 100 nm
Rise Time 3.0 nsec 2.7 nsec 5.0 nsec
Typical Budget · Receive Sensitivity · Peak Input Power

Table 2-9. TPIM-F3 Specifications
Parameter Typical Minimum Maximum
Fall Time 2.5 nsec 2.2 nsec 5.0 nsec
Duty Cycle 50.1% 49.6% 50.7%
For a 4°C temperature increase, multiply the typical coefficient (-0.15 dBm) by four and add the result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).
Maximum Sensitivity (-36.0)
Typical Sensitivity (-31.0)
Minimum Sensitivity (-30.0)
Minimum Receive Input (-9.72)
Typical Receive Input (-7.5)
Maximum Receive Input (-6.99)
Maximum Transmit Power (-12.0)
(At 25°C into 8.3/125µm fiber)
Typical Transmit Power (-15.5)
Minimum Transmit Power (-21.0)
-40 -35 -30 -25 -20 -15 -10 -5 0
Less Power More Power
* Transmit Power Typical Power Minimum Power Maximum Power Coefficient (See Note Below) -0.15dBm/°C -0.12 dBm/°C -0.18 dBm/°
When measuring power levels with an Average Power Meter, add 3 dBm

to the average power measurement to correctly compare the average power values measured to the values listed above (i.e., -33.5 dBm average + 3 dB = -30.5 dBm peak).
Cabletron Systems reserves the right to change the following operating specifications at any time without notice:
The power supply has two outputs of +5 volts and +12 volts. Maximum output power is 125 watts and the minimum efficiency is 65% under all conditions of line at full load. The minimum and maximum load current from each output is shown below.
Table 2-10.
Output Min. Load Max. Load Max Power
+ 5 Volts 1.00 Amps 15 Amps 75 Watts
+12 Volts 0.15 Amps 4 Amps 48 Watts

This unit meets the safety requirements of UL 1950, CSA C22.2 No. 950 and EN 60950; the EMI requirements of FCC Class A and EN 55022 Class A; and the EMC requirements of EN 50082-1.
Dimensions:
2.8H x 17.0W x 13.5D inches (7.2H x 43.6W x 34.6D cm)
Weight:
MTBF >944,197 hours projected
MTTR

INSTALLATION
This chapter outlines MicroMMAC-T installation and network connection procedures. Be sure that the network meets the guidelines and requirements outlined in Chapter 2, Requirements/Specifications, before installing the MicroMMAC-T.
Unpack the module carefully. Preserve and save all packaging materials for possible storage or transport of the MicroMMAC-T.
Thoroughly inspect the MicroMMAC-T immediately. If there are any signs of damage to the module, contact Cabletron Systems Technical Support immediately.
Attach the strain relief bracket to the front of the MicroMMAC-T as described:

TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
Figure 3-1. Attaching the Strain Relief Bracket
The MicroMMAC-T can be rack-mounted, wall-mounted, or placed on any horizontal surface. Refer to the following subsections for the appropriate installation instructions. When installing the MicroMMAC-T into something other than a 19-inch rack, installation requires the following:
Refer to Figure 3-2 and perform the following steps to install the MicroMMAC-T in a 19-inch rack:

TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
Figure 3-2. Installing of Rack-Mount Brackets
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
Figure 3-3. Installing the MicroMMAC-T in a 19-inch Rack
When wall-mounting the MicroMMAC-T, the TCU ports must face downward. Perform the following steps to wall-mount the MicroMMAC-T:

Figure 3-4. Wall-Mounting the MicroMMAC-T

3.3.3 Free-Standing Installation
For a free-standing shelf or table top installation, locate the MicroMMAC-T, as shown in Figure 3-5, within 7 feet of its power source on an unrestricted free surface area 21 inches wide, 18 inches deep, and 6 inches high.
21 IN.
18 IN.
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
6 IN.
Max. Dist. 7 FT.
Figure 3-5. Free-Standing Installation
To connect the MicroMMAC-T to the power source, plug the power cord into a grounded wall outlet. After the MicroMMAC-T runs a self test, the CPU LED blinks green to indicate normal operation. If the LED remains red, the processor is faulty.
The MicroMMAC-T reset button is located on the left front panel as shown in Figure 3-6.

To reset the MicroMMAC-T:
Insert a small pointed-tip object (e.g., ballpoint pen) into the recessed reset button hole, press the button once, and then release.
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
4 Mb 16 Mb
RESET SWITCH RESET BUTTON
Figure 3-6. The Reset Button
The ring speed switch is located on the front face of the MicroMMAC-T as shown in Figure 3-7.
The MicroMMAC-T’s factory-default ring speed setting is 16 Mbps.
To change the ring speed: 1. Slide the ring speed switch to the desired setting.

TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
4 Mb 16 Mb
Ring Speed LED Indicator On = 16 Mbps Off = 4 Mbps
4 Mb 16 Mb
Figure 3-7. The Ring Speed Switch
Figure 3-8 shows the location of the NVRAM Reset Switch. It can be reached by a inserting a small screwdriver through the side vent. NVRAM (Non-Volatile Random Access Memory) stores user-entered parameters such as IP address and device name.
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
IN HERE
Figure 3-8. NVRAM Reset Switch Location
To restore MicroMMAC-T parameters to the factory defaults: 1. With power-ON, toggle the NVRAM switch from one position to the other.

Once the module is reset, use the factory-default settings or enter new parameters. The MicroMMAC-T stores these settings in NVRAM during normal operation and during power down until the reset switch is toggled again.
The MicroMMACs 22T and 24T have unshielded RJ45 lobe ports that support UTP cabling. To connect a UTP segment from the MicroMMAC-T to a station supporting STP cabling, a Type 3 Media Filter is required. The Cabletron Systems TRMF and TRMF-2 are available for this purpose.
The MicroMMACs 42T and 44T have shielded RJ45 lobe ports that support STP cabling. Shielded patch cables that adapt a shielded RJ45 to a data connector (MIC) are available from Cabletron Systems (PN 9372057-8). These adapter/patch cables allow connection to an existing patch panel equipped with data connectors. The MicroMMAC-T’s network lobe port pinouts are shown in Figure 3-9.
RJ45 Plug to MIC Connector
Pin 3 (Receive -) to . . . Green (Transmit -) Pin 4 (Transmit +) to . . . Orange (Receive +) Pin 5 (Transmit -) to . . . Black (Receive -) Pin 6 (Receive +) to . . . Blue (Transmit +)

RJ45 Plug to RJ45 Plug (at TCU) (at device port)
Pin 3 (Receive -) to Pin 3 (Transmit -) Pin 4 (Transmit +) to Pin 4 (Receive +) Pin 5 (Transmit -) to Pin 5 (Receive -) Pin 6 (Receive +) to Pin 6 (Transmit +)
Figure 3-9. Network lobe pinouts
Figure 3-10 and Figure 3-11 illustrate possible MicroMMAC-T cabling configurations.
RJ45 Plug · RJ45 Plug


TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
CPU ACT MGMT 16 Mb/s COM 1 COM 2


TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
CPU ACT MGMT 16 Mb/s COM 1 COM 2
To attach a lobe segment to a MicroMMAC-T network port: 1. Insert the RJ45 connector from each twisted pair segment into an RJ45 network lobe port on the MicroMMAC-T, as shown in Figure 3-12.

a. Check that the device at the other end of the twisted pair segment has power, and that the network interface driver is initialized.
b. Verify the RJ45 connector pinouts on the twisted pair segment.
c. Check that the twisted pair connection meets the dB loss limits and cable specifications outlined in Chapter 2.
d. Check Local Management to ensure that the port is enabled.
e. If a link still can not be established, contact Cabletron Systems Technical Support.
TPIMs provide specialized RI/RO ports for trunk connections. Each TPIM supports a different medium (cable type). Different TPIMs may be operated together: for example, a TPIM-T1 can provide a Ring-In port while a TPIM-T4 provides a Ring-Out port.
The following sub-sections explain how to set the Phantom and RI/RO Switches, how to install a TPIM into a MicroMMAC-T, and how to attach network segments through the TPIM.
Prior to connecting trunk cabling to the TPIMs, check the connectors for proper pinouts. Table 3-1 provides a cross-reference of pinouts for TPIMs used for Ring-In or Ring-Out applications.
Table 3-1. Pinout Cross-Reference for TPIMs
TPIM-T2/T4
TPIM-T1
TPIM-T1
(RJ45)
(RJ45)
(DB9)
(DB9)
TX+ 6 4 9 1
TX3 5 5 6

Table 3-1. Pinout Cross-Reference for TPIMs (Cont.)
TPIM-T2/T4
TPIM-T1
TPIM-T1
(RJ45)
(RJ45)
(DB9)
(DB9)
RX+ 4 6 1 9
RX5 3 6 5
3.9.1 Setting Phantom and RI/RO Switches
The Phantom Switch (shown in Figure 3-13) enables the port to “autowrap” if a trunk cable fails or is removed. The Phantom Switch should be set to the appropriate setting before TPIM installation. When attaching a Cabletron hub to the TPIM, leave the switch at the factory default setting of 1. When attaching a non-Cabletron device to the TPIM, such as an IBM 8228 MAU, use the 0 setting.
Ensure that the Ring-In/Ring-Out Switch is in the factory default RI/RO position. The MicroMMAC-T does not support the Station (S) setting.

P H A N T O M
(See Below For Settings)
S RI/RO
TPIM-T1/TPIM-T2/TPIM-T4
TPIM-F2/TPIM-F3
Phantom Switch Settings 1 = Cabletron Device (Default) 0 = Non-Cabletron Device
RI/RO Switch Settings RI/RO = Ring In Ring Out (Default) STN = Station (Not Functional)
RI/RO Switch Settings RI/RO = Ring In/Ring Out (Default) S = Station (Not Functional)
Figure 3-13. The Phantom and RI/RO Switches
To install a TPIM, perform the following steps:
Top View

18 17 16 15 14 13
6 5 4 3 2 1
TPIM-T1
Figure 3-14. Installing a TPIM
Use TPIM-T1 to connect STP segments. Before connecting a segment to the TPIM-T1, confirm proper pinouts at each end of the segment.
To connect a TPIM-T1 to a Twisted Pair Segment: 1. Insert the DB9 connector on the segment into the DB9 port on the TPIM as shown in Figure 3-15.

18 17 16 15 14 13
TPIM-T1
6 5 4 3 2 1
Figure 3-15. The TPIM-T1
a. Check that the device at the other end of the segment has power.
b. Verify that the DB9 connector is pinned properly.
c. Check that the twisted pair connection meets dB loss limits and cable specifications outlined in Chapter 2.
d. Check that the port is enabled through the Local Management.
e. If a link still cannot be established, contact Cabletron Systems Technical Support.
The TPIM-T2 supports UTP cabling and the TPIM-T4 supports STP cabling. Both devices use the same method for connecting an RJ45 connector to an RJ45 port. Before connecting a segment to the TPIM-T2 /T4, check each end of the segment to ensure the wires are pinned properly.
To connect a segment to a TPIM-T2/-T4: 1. Insert the RJ45 connector on the twisted pair segment into the RJ45 port on the TPIM as shown in Figure 3-16.

RO
LNK
TPIM-T2
18 17 16 15 14 13
TPIM-T2
6 5 4 3 2 1
Figure 3-16. The TPIM-T2/-T4
a. Check that the device at the other end of the segment has power.
b. Verify that the RJ45 is pinned properly.
c. Check that the twisted pair connection meets dB loss limits and cable specifications outlined in Chapter 2.
d. Check that the port is enabled through Local Management.
e. If a link still can not be established, contact Cabletron Systems Technical Support.
Use TPIMs -F2/ -F3 to connect Fiber Optic Link segments. When connecting a fiber optic link segment to the TPIM-F2 or TPIM-F3 consider the following:

To connect a fiber optic link segment to the TPIM-F2 /-F3: 1. Remove the protective plastic covers from the appropriate fiber optic ports on the module and from the ends of the connectors on each fiber strand.
RX TX
LNK
TPIM-F2
18 17 16 15 14 13
LNK
TPIM-F2
6 5 4 3 2 1
Figure 3-17. The TPIM-F2/-F3

a. Check that the device at the other end of the link has power.
b. Verify that the fiber strands are properly “crossed-over” between the ports on the module and on the fiber optic device at the other end of the fiber optic link segment.
c. Verify that the fiber connection meets the dB loss limit specifications outlined in Chapter 2.
d. Check that the port is enabled through MicroMMAC-T Local Management.
e. If a link still can not be established, contact Cabletron Systems Technical Support.
To check MicroMMAC-T installation: 1. Trace the ring path through the network to be sure that there are no breaks in the ring and that it is free from logical design errors.
a. Check that each cable connection is secure and logically correct.
b. Verify the pinouts for each connection.
c. Use a cable tester to check the cable conductors for continuity.
When these checks are successfully cleared, the MicroMMAC-T is ready for normal operation. If errors or other problems are encountered, see Chapter 5, Troubleshooting, for information about diagnosing operational problems.
If problems still occur, contact your Cabletron Technical Support representative.

This chapter explains how to set up a management terminal and a modem to access MicroMMAC-T’s Local Management (LM). It also explains how to use Local Management tools to manage the MicroMMAC-T, its components, and its attached segments (i.e., BRIMs, MicroSNAC).
Use Local Management to Do the Following: • Control password access to the MicroMMAC-T
To access Local Management, use one of the following management terminals:

Cabletron supplies an RJ45 Cable Kit with the MicroMMAC-T. This kit includes a UTP console cable with RJ45 connectors on each end. It also provides adapters for DB9 or DB25 connections. Refer to the RJ45 Cable Kit Instruction Sheet for adapter pinouts and additional instructions.
The following sections explain how to attach the console cable to the management terminal.
To attach a management terminal to the MicroMMAC-T: 1. Attach the connecting cable’s male RJ45 connector to either the COM 1 port or the COM 2 port on the MicroMMAC-T as shown in Figure 4-1.
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM STP CABLE MicroMMAC-24T
MANAGEMENT TERMINAL
Figure 4-1. Management Terminal Connection
Table 4-1 lists the setup parameters for the Local Management terminal. If you are using a Digital Equipment Corporation VT terminal, press F3 to access the Setup Directory. For PC emulations of VT terminals, refer to the emulator’s documentation for setup parameters.

When you have finished attaching and setting up the terminal, you can access Local Management.
Table 4-1. Terminal Settings for LM Terminal
Display Setup Columns 80 Columns
Auto Wrap No Auto Wrap
General Setup Mode VT 100,
Cursor Keys Normal Cursor Keys
Transmit Transmit = 9600
Receive Receive = Transmit
Bits, Parity 8 Bits, No Parity
Stop Bit 1 Stop Bit
Local Echo No Local Echo
Port Data Leads Only
Keyboard Setup Keys Typewriter Keys
Margin Bell Margin Bell
To access Local Management from a modem, use an RS-232 cable available from Cabletron Systems. This cable connects the modem to the

MicroMMAC-T’s COM 2 port. Figure 4-2 shows the pinout for a cable with an RJ45 connector at the MicroMMAC-T end of the cable.
RJ45 TO 25-PIN
CABLE
RJ45 COM 2
25-Pin Female "D" Shell Connector
TRANSMIT
RECEIVE RECEIVE
SIGNAL GROUND SIGNAL GROUND
DATA CARRIER DETECT DATA CARRIER DETECT 2 8
DATA TERMINAL READY
20 DATA TERMINAL READY
8 2 RING
RING
Figure 4-2. Modem Cable Pinouts
To access Local Management: 1. Turn on the display terminal and then press the Return key.
The MicroMMAC-T Local Management screen (Figure 4-3) appears.
Pin 1 · Port

CABLETRON Systems, Incorporated P.O. Box 5005 Rochester, NH 03867-5005 USA (603) 332-9400
(c) Copyright CABLETRON Systems, Inc. 1995
Device Model Number: 00.00.01 Serial Number: 00.00.01 Functionality Level: 00.00.01 Flash Image Version: 01.00.01 BOOTPROM Version: 01.00.01 Board Revision: 00.00.01
Figure 4-3. MicroMMAC-T Local Management Screen
If your password is invalid, the cursor returns to the beginning of the password field; otherwise, the MAIN MENU screen appears. Figure 4-4 shows the MAIN MENU screen at the top of the representational screen-access hierarchy.
Once the MicroMMAC-T is given a valid IP address (see Section 4.3.2 for information on setting an IP address), you can establish a Telnet session with Local Management from any TCP/IP based node on the network.
uMMAC-T Local Management

The MicroMMAC-T Local Management screen appears when you establish a connection (Figure 4-3).
The MENU screens, shown in Figure 4-4, provide access to all MicroMMAC-T Local Management tools:
The MAIN MENU screen is the gateway to all other Local Management MENU screens and the tools they provide. It also lets you access the DEVICE STATISTICS and Management Information Base (MIB) NAVIGATOR screens.
Selections from the SETUP MENU screen let you setup and manage system parameters, establish community names, designate traps, download Flash images and establish ring security privileges.
Selections from the STATUS MENU screen let you control access to MicroMMAC-T ports and monitor chassis and component functions.
MAIN MENU Screen · SETUP MENU Screen · STATUS MENU Screen

uMMAC-T Local Management Flash Image Version: 01.00.01
SETUP MENU
STATUS MENU
DEVICE STATISTICS
MIB NAVIGATOR
EXIT
uMMAC-T Local Management Flash Image Version: 01.00.01
uMMAC-T Local Management Flash Image Version: 01.00.01
SETUP MENU
CHASSIS STATUS COMPONENT STATUS
SYSTEM LEVEL SNMP COMMUNITY NAMES SNMP TRAPS FLASH DOWNLOAD RING SECURITY
RETURN
Figure 4-4. Local Management MENU Screens Hierarchy
This section describes how to work with all LM screens.
Selecting a MENU Screen Option 1. Use the Tab key or arrow keys to highlight a MENU option.
The selected screen appears.
Setting or Modifying Local Management Screen Fields
Local Management screen lets you set or modify and then save system fields, or parameters, singularly or globally. Use the following procedures

(or other procedures where they are described) when working with LM screens:
The “SAVED” message appears on the screen indicating that your change(s) have been saved to memory.
If you decide to exit the screen without saving your changes, the “NOT SAVED-PRESS SAVE TO KEEP YOUR CHANGES” appears on the screen.
Exiting a Local Management Screen 1. Use the Tab key or arrow keys to highlight the RETURN command at the bottom of the screen.
Local Management returns you to the previous MENU screen.
Exiting Your Local Management Session 1. Use the Tab key or arrow keys to highlight the RETURN command at the bottom of the screen.
The Local Management screen disappears.
The remainder of this chapter describes Local Management screens and how to use the tools they provide.

The SYSTEM LEVEL Screen (Figure 4-5) displays and lets you set the following parameters:
It also displays the Physical MAC device address and the Default Interface.
uMMAC-T Local Management Flash Image Version: 01.00.01
Host IP Address Subnet Mask Default Interface Default Gateway xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx NONE DEFINED NONE DEFINED
Beacon Recovery [ ENABLED ] Number of Retries(000-100,999-infinite):004 Retry Interval(000-999):021
Local Admin Addr [ DISABLED ]: 40-00-00-00-00-00 Physical MAC Address: 00-00-B8-28-08-54
Figure 4-5. SYSTEM LEVEL Screen
The following sections describe SYSTEM LEVEL screen fields, their functions, and where applicable, how to use them.
Setting the System Date
Use this field to set the correct date.

The “SAVED” message appears on the screen indicating that your change have been saved to memory.
Setting the System Time
Use this field to set the correct time.
The “SAVED” message appears on the screen indicating that your changes have been saved to memory.
Setting the Host IP Address
Use this field to set the Internet Protocol (IP) address for the MicroMMAC-T.
If the format is invalid, the message “INVALID IP FORMAT” appears. Retype the IP Address using the correct format.

The new value appears in the IP Address field.
The “SAVED” message appears on the screen indicating that your changes have been saved to memory.
The MicroMMAC-T will then do a soft reset.
Modifying the Subnet Mask
Subnets are logical divisions of the network that serve to isolate groups of devices. The Subnet Mask determines how the MicroMMAC-T directs SNMP Trap messages (see Section 4.3.4 for information about SNMP Traps) to a destination address. The MicroMMAC-T directly addresses destinations within its own subnet. The MicroMMAC-T sends messages destined for other subnets to a router.
To modify the Subnet Mask: 1. Highlight the Subnet Mask field.
If the format is not valid, the “INVALID IP FORMAT” message appears. Retype the Subnet Mask using the correct format.

The “SAVED” message appears on the screen indicating that your changes have been saved to memory.
The MicroMMAC-T will then do a soft reset.
Setting the Default Gateway
The Default Gateway is the IP address of the network connection (e.g., external router) used in forwarding management information from the MicroMMAC-T (e.g., SNMP traps) to a network management station. Use the Default Gateway in conjunction with the Subnet Mask.
To set the Default Gateway: 1. Highlight the Default Gateway field.
If the format is invalid, the message “INVALID IP FORMAT” appears. Re-type the IP Address using the correct format.
The “SAVED” message appears on the screen indicating that your changes have been saved to memory.
The MicroMMAC-T will then do a soft reset
Setting Automatic Beacon Recovery Process (ABRP) Fields
Beaconing is part of a standard IEEE 802.5 Token Ring process by which a Token Ring LAN attempts to recover from cable or hardware problems by automatically locating and bypassing the fault, thereby restoring network communications without operator intervention. If the standard process fails, beaconing can disable a token ring network. Cabletron’s ABRP protects against such network stoppages.
The ABRP is automatically invoked whenever a Token Ring network component problem creates a beaconing condition, and it is often able to correct the problem before the standard IEEE process begins. Once the

ABRP locates the problem and corrects it, the MicroMMAC-T generates traps to provide the network’s designated remote management station with information regarding the incident, including:
The MicroMMAC-T provides the following ABRP management fields:
The Beacon Recovery field indicates the current status of the ABRP at the device. The ABRP occurs for the MicroMMAC-T ports and STH ports under MicroMMAC-T control only. ENABLED is the default setting in this field and indicates that the ABRP is currently active at the device; DISABLED indicates that the ABRP is inactive at the device.
The Number of Retries field displays and lets you modify the number of times you want the MicroMMAC-T to try to re-enable a disabled port from which a beaconing condition was detected. The default number of retries is 4. You can enter values from the range specified in the parentheses (000-100, 999: infinite).
The Retry Interval field displays and lets you modify the time delay (in increments of 7 seconds) between ring port retry attempts. The default setting is 21.
To set the Beacon Recovery field: 1. Highlight the Beacon Recovery field

The “SAVE” message appears on the screen indicating that your selection was saved to memory and the new value of the field takes effect.
To set the Number of Retries field: 1. Highlight the Number of Retries field and type in an allowed value.
The “SAVE” message appears on the screen indicating that your selection was saved to memory and the new value of the field takes effect.
To set the Retry Interval field: 1. Highlight the Retry Interval field and type in an allowed value (in increments of 7 only).
The “SAVE” message appears on the screen indicating that your selection was saved to memory and the new value of the field takes effect.
Setting COM 1 and COM 2 Applications
You can select COM port settings for LM, SLIP, UPS, Telnet, or a modem.
The “SAVE” message appears on the screen indicating that your selection was saved to memory and the new value of the field takes effect.
Use the SNMP COMMUNITY NAMES (Figure 4-6) screen to establish SNMP community names for the MicroMMAC-T. Community names

serve two purposes: they act as passwords to Local Management (LM) and control SNMP management access to the MicroMMAC-T.
You control MicroMMAC-T access by establishing access policy privileges at three increasingly higher levels of security:
If a user who lacks proper authorization attempts to edit a field, the following message appears: “AUTHORIZATION PROHIBITS ACCESS”.
uMMAC-T Local Management Flash Image Version: 01.00.01
Community Name Access Policy
public read-only public read-write public super-user
Figure 4-6. SNMP COMMUNITY NAMES Screen
Instructions for using SNMP COMMUNITY NAMES screen fields are provided below.

This field displays designated user names.
This field displays the access privileges accorded to each community name.
Editing the Community Name field 1. Highlight the Community Name field.
If you press the Return key without entering a password, the field defaults to Public.
The “SAVED” message appears indicating that your changes have been saved to memory.
Use the SNMP TRAPS screen (Figure 4-7) to designate which remote management workstations will receive traps from the MicroMMAC-T. Traps provide messages about network and device operational statistics.
Community Name · Access Policy

uMMAC-T Local Management Flash Image Version: 01.00.01
Trap Destination Trap Community Name Enable Traps
xxx.xxx.xxx.xxx public [YES] xxx.xxx.xxx.xxx public [YES] xxx.xxx.xxx.xxx public [YES] xxx.xxx.xxx.xxx public [YES] xxx.xxx.xxx.xxx public [NO] xxx.xxx.xxx.xxx public [NO] xxx.xxx.xxx.xxx public [NO] xxx.xxx.xxx.xxx public [NO]
Figure 4-7. SNMP TRAPS Screen
The following sections discuss the fields on the SNMP TRAPS Screen and provide instructions for using them.
This field shows the IP Address of the workstation that receives traps from the MicroMMAC-T.
This field displays the user-defined name of the SNMP Compliant Network Management Stations that receive traps.
This field lets you enable the transmission of SNMP trap messages.
Setting SNMP Traps 1. Highlight the Trap Destination field.
Trap Destination · Trap Community Name · Enable Traps

If the format is invalid, the “INVALID IP FORMAT” message appears. Re-type the Trap Destination IP address using the correct format.
If you press the Return key without entering a community name, the field defaults to .
The “SAVED” message appears indicating that your changes have been saved to memory.
The MicroMMAC-T acts as the Ring Security Monitor for the entire ring. Users who have Super-User privileges can control access to the Token Ring network through the RING SECURITY screen (Figure 4-8). When Ring Security is enabled, the MicroMMAC-T stores in a secure database in NVRAM an allowed stations list consisting of the MAC addresses of up to 255 stations on the network.

uMMAC-T Local Management Flash Image Version: 01.00.01
Stn Edit 00-00-00-00-00-00 [ Add ] Security Mode [ Disabled ]
Figure 4-8. RING SECURITY Screen
Only stations on the ring’s allowed list can enter the ring. The MicroMMAC-T retains this allowed list and automatically re-enables ring security whenever you power up or reset the unit.
You can select from two modes of ring security:
Use the MicroMMAC-T in Alarm Only mode to add stations to the ring’s allowed list. In Alarm Only mode, new stations can enter the ring, but a “station added” trap notifies the Network Management Station (NMS) of the event. The trap includes the new station’s MAC address so that you can decide whether to retain the new station on the ring.
Each address you approve automatically becomes part of the ring’s allowed list. Later, you can add more stations to the allowed list by temporarily disabling ring security, then re-enabling it using the Alarm Only feature.
STATION ADDRESS xx-xx-xx-xx-xx-xx

In Alarm/Remove mode, the MicroMMAC-T sends a “Remove MAC Frame Command” to new stations attempting to enter the ring. A trap sent to the NMS informs it of the action taken. If the Remove MAC Frame Command fails to remove the new station after three attempts, a trap to the NMS informs it that “the station could not be removed.”
The following sections discuss RING SECURITY screen fields and provide instructions for using them.
This field lists up to 255 MAC addresses on the ring security allowed list.
Use the Station Edit command to add or delete stations from the allowed list and to edit single entries on the allowed list.
Use this command to set the level of security for the ring. Select from the following Security Modes:
Stn Edit · Security Mode

it sends a trap to the NMS informing it that the station could not be removed. The station must then be physically removed from the ring.
Use this field to save changes made to ring security in the MicroMMAC-T’s NVRAM. You must use the SAVE/EXECUTE command for your changes to take effect.
Use this command to scroll to the next screen of the allowed list database.
Use this command to scroll back to the previous screen of the allowed list database.
Use this command to exit the RING SECURITY screen and return to the SETUP MENU screen.
Changing the Security Mode 1. Highlight the Security Mode field.
The MicroMMAC-T enables the selected mode of ring security. The following message appears at the top of the screen: “SECURITY MODE CHANGED.”
Building the Allowed List Automatically 1. Set the Security Mode to Disabled (as described above) and then set the Security Mode to Alarm Only.
Ring Security automatically builds an allowed list only after the Alarm Only mode has been invoked from the Disabled mode.

Viewing the Revised Allowed List 1. Highlight the RETURN command and then press the Return key.
The SETUP MENU screen appears.
The RING SECURITY screen appears, showing the revised Station Address allowed list.
Adding Stations to the STATION ADDRESS Allowed List 1. Highlight the Stn Edit field.
The new MAC address appears on the STATION ADDRESS allowed list.
Deleting Stations from the STATION ADDRESS Allowed List 1. Set ring security to the Alarm/Remove mode.
The station’s MAC address no longer appears on the STATION ADDRESS allowed list.

The DEVICE STATISTICS screen (Figure 4-9) displays ring information, isolating errors, and non-isolating errors.
uMMAC-T Local Management Flash Image Version: 01.00.01
RING INFORMATION Frames Received: 4572 Active Monitor Addr: 00-00-B8-28-08-54 KBytes Received: 10157 Ring Status: Normal Errors Received: 0 Ring Number: 0 Beacon States: 0 Stations on Ring: 1 Ring Purges: 2 Ports Enabled: 0 Active Monitor Changes: 1 Ring Speed (Mb/s): 4
ISOLATING ERRORS NON-ISOLATING ERRORS Line Errors: 0 Lost Frame Errors: 0 Burst Errors: 0 Frame Copied Errors: 0 AC Errors: 0 Rcvr Congestion Errors: 0 Abort Transmit Errors: 0 Token Errors: 0 Internal Errors: 0 Frequency Errors: 0
[ TOTAL ] [ REFRESH 3sec ] RETURN
Figure 4-9. DEVICE STATISTICS Screen
The following sections discuss the fields on the DEVICE STATISTICS screen and provide instructions for using them.
The DEVICE STATISTICS counter mode field at the top of the screen (Figure 4-9 shows an sample screen in the TOTAL counter mode) displays the method used for compiling device statistics. The method is selected from the corresponding counter mode field located at the bottom of the screen.
The MicroMMAC-T compiles and displays statistics from three separate counter modes:

Selecting the Device Statistics Counter Mode 1. Highlight the current mode at the bottom of the screen and toggle to a counter mode selection.
The selected counter mode appears at the top and the bottom of the screen.
Using the ACCUMULATIVE Counter Mode 1. Select the ACCUMULATIVE counter mode.
The following fields appear on the screen: Date Cleared and Time Cleared in the upper right part of the screen and Clear at the lower left part of the screen.
The Date Clear and Time Clear fields change to reflect the beginning of the period over which you want to view device statistics.
Setting the Refresh Field
This field displays the time interval between screen counter updates. You can choose refresh intervals from 3 to 10 seconds.
DEVICE STATISTICS screen read-only fields are described below:
This field displays the frames received by the MicroMMAC-T.
Frames Received

This field displays the sum in kilobytes of frames received by the MicroMMAC-T.
This field displays the Isolating and Non-Isolating Errors (described below) detected on the ring.
This field displays the beacon conditions detected on the ring. Stations transmit beacons when they detect bit streaming or signal loss on the ring.
This field displays the ring purge frames transmitted by the active monitor.
This field displays the number of times the active monitor has changed.
Isolating Errors are “soft” ring errors that indicate the domain of a fault. That is, the active monitor can isolate the fault’s region to the transmitting adapter, the receiving adapter, the cable, and the components between them. The errors are described below:
This field displays the total line errors detected on the ring. Line Errors are corrupted frames that are detected by a node. This type of error normally occurs when stations enter and leave the ring.
This error can also indicate a problem with the receiver of the reporting node, or the transmitter of its Nearest Active Upstream Neighbor (NAUN), or the cabling and hub hardware between them.
This field displays the total burst errors detected on the ring. Burst Errors are the absence of clocking signals at a node’s receiver. This error normally

occurs when stations enter or leave the ring with the absence of phantom current.
This error can also indicate a problem with the receiver of the reporting node, or the transmitter of its NAUN, or the cabling and hub hardware between them.
This field displays the total Address Recognized/Frame Copied errors. This indicates that the reporting NAUN is faulty. The node cannot set the address recognized indicator and/or frame copied indicator bits in the frame which it has copied. This leaves the downstream node with an incorrect NAUN address.
This field displays the total abort delimiter frames transmitted by a station. This indicates that either the reporting node has detected an error on itself, or there is an error with its NAUN, or the cabling and wiring hubs between them.
This field displays the total internal errors detected by the adapter’s hardware and/or firmware. These errors cause the adapter to remove itself from the ring and indicates a problem with the adapter hardware or firmware.
Ring Information provides ring status information.
This field displays the MAC address of the active monitor. The active monitor initiates recovery procedures from various error situations.
This field displays the following Ring Status conditions:

This field displays the assigned number of rings on the network.
Stations on a Ring
This field displays the number of stations inserted into the ring.
This field displays the number of network lobe ports enabled.
This field displays the ring speed of the MicroMMAC-T as either 4 Mb/s or 16 Mb/s.
Non-Isolating Errors are “soft error” conditions that could have been caused by any station on the ring. Their fault domain cannot be detected.
This field displays the total number of Lost Frame Errors. These errors occur when the adapter fails to receive the end of the frame it has just transmitted. The frame was lost somewhere on the ring but there is no way to pinpoint where. This can be caused by stations entering or leaving the ring.

This field displays the total number of Frame Copied Errors. These errors occur when a station finds a frame with its address as the destination, but finds the address recognized indicator bits not set to zero. This indicates a possible duplicate address.
This field displays the total number of Rcvr Congestion Errors. This indicates a station is receiving/repeating a frame and recognizes a frame addressed to it, but has no buffer space available for the frame.
This field displays the total number of Token Errors. Token Errors occur when an active monitor does not see a token circulating on the ring before its Timer Valid Transmission (TVX) time expires (e.g. a lost frame error has occurred), or sees a recirculating frame or token. The active monitor is responsible for purging the ring and issuing a new token.
This field displays the total number of frequency errors. This indicates that the frequency of the incoming signal deviates excessively from the adapter’s onboard crystal oscillator. It could indicate an error in this node’s oscillator, the active monitor, or any node in between. When the node detects a frequency error, it enters the monitor contention process to establish a new active monitor.
The CHASSIS STATUS VIEW screen lets you monitor and manage the operational status of the station ports and RI/RO ports on the MicroMMAC-T and the station ports on its attached non-intelligent STH hubs. It also lets you monitor and managed attached BRIMs (the CR-BRIM-W/T and the MicroSNAC device provide their own comprehensive console access management tools).
The CHASSIS STATUS VIEW screen supports three separate screen modes:

The following sections describe generic CHASSIS STATUS VIEW screen fields and control procedures.
This field, located within parentheses next to the screen title, displays the current screen mode.
These fields consist of the columns of numbered ports located under the device identifiers (MMAC24, STH24, et al). They display port-status information and let you selectively enable and disable ports when in the ADMINISTRATIVE mode.
Virtual Flexible Network Bus (VFNB)
Use this field (a quasi Network Bus), located at the top of each the port-status column under the device identifier, to either bypass or activate a module, or hub, when in the ADMINISTRATIVE mode.
Possible VFNB screen configurations for Enabled modules are described as follows:
Mode · Port Status

VFNB screen configurations for Bypassed modules are described as follows:
Use this field to select ADMINISTRATIVE, OPERATIONAL, or RING OUT ENABLE screen status modes. It is located within parentheses at the bottom of the screen.
ENABLE ALL PORTS (ADMINISTRATIVE mode only)
Use this field to enable all MicroMMAC-T and connected STH hub ports.
Use this field to scroll to the next screen.
Use this field to scroll to the previous screen. This field appears only after the NEXT command has been invoked.
This field displays the time interval between screen counter updates. You can choose refresh intervals of 3 to 10 seconds.
Use this field to return to the STATUS MENU screen.
Selecting OPERATIONAL, ADMINISTRATIVE, or RING OUT ENABLE Mode Screens 1. Highlight the screen mode status field.
Screen Mode Status

The selected screen mode appears.
Setting the REFRESH Field 1. Highlight the REFRESH3sec field.
Using the OPERATIONAL Mode Screen
The OPERATIONAL mode screen (Figure 4-10) is a display-only screen that shows the token ring access status of hub ports and devices. By default the OPERATIONAL mode screen shows the status of ports 1-12 for the MicroMMAC-T and attached STH hubs.
uMMAC-T Local Management Flash Image Version: 01.00.01
CHASSIS STATUS VIEW ( OPERATIONAL ) 5 4 3 2 1 STH24 MMAC24 |---> <---| 16Mb/s 16Mb/s 1 [BYP] 1 [INS] 2 [BYP] 2 [INS] 3 [ENB] 3 [INS] 4 [LNK] 4 [INS] 5 [LNK] 5 [INS] 6 [LNK] 6 [ENB] 7 [ENB] 7 [ENB] 8 [ENB] 8 [ENB] 9 [INS] 9 [ENB] 10 [INS] 10 [ENB] 11 [INS] 11 [ENB] 12 [INS] 12 [ENB]
NEXT [ OPERATIONAL ] [ REFRESH 3sec ] RETURN
Figure 4-10. CHASSIS STATUS VIEW (OPERATIONAL) Screen
Station ports, on any module, can be in either of the following four operational states:

Ring In/Ring Out ports can be in either of the following two operational states:
BRIMs and the MicroSNAC device can be in either of two operational states: ENB or BYP.
To display the status of ports 13-24: 1. Highlight the NEXT command and then press the Return key.
The screen displays the status of ports 13-24 for all modules.
To display the status of RI/RO ports, BRIMs, or the MicroSNAC device: 1. Highlight the NEXT command and then press the Return key.
Repeat Step 1. as many times as necessary to display the status of the device you want.
The screen displays the selected device’s status.

Using the ADMINISTRATIVE Mode Screen
In addition to displaying the operational status of ring ports, the ADMINISTRATIVE mode screen provides you with two methods for controlling access to them:
When you bypass a module, or device, you not only remove it from the Token Ring to which it was previously attached, but you also establish a separate, or stand-alone, Token Ring composed only of the terminals attached to the ports on the bypassed module.
This capability is useful, for example, when you want to establish a secondary ring to run at a slower data transmission speed, or for segregating a user group sharing a common application, or for security reasons.
Enabling or disabling ports simply turns them on and off.
uMMAC-T Local Management Flash Image Version: 01.00.01
CHASSIS STATUS VIEW ( ADMINISTRATIVE ) 5 4 3 2 1 STH24 MMAC24 |---> <---| 16Mb/s 16Mb/s 1 [ON] 1 [ON] 2 [ON] 2 [ON] 3 [ON] 3 [ON] 4 [ON] 4 [ON] 5 [ON] 5 [ON] 6 [ON] 6 [ON] 7 [ON] 7 [OFF] 8 [ON] 8 [OFF] 9 [ON] 9 [OFF] 10 [ON] 10 [OFF] 11 [ON] 11 [OFF] 12 [ON] 12 [OFF]
NEXT ENABLE ALL PORTS [ ADMINISTRATIVE ] [ REFRESH 3sec ] RETURN
Figure 4-11. CHASSIS STATUS VIEW (ADMINISTRATIVE) Screen
To enable and disable select ports: 1. Highlight the port status fields showing either ON or OFF.

Enabled ports provide access for other stations into the token ring network; disabled ports cannot provide access to the ring until they have been enabled.
To enable all ports for all modules: 1. Highlight the ENABLE ALL PORTS field.
All ports are enabled.
To bypass all ports on a module: 1. Highlight the VFNB (located under the module identifier).
The entire module is bypassed from the Token Ring.
To reconnect a module to the token ring: 1. Highlight the bypass mode identifier, (-B-).
The module is now connected to the Token Ring.
Using the RING OUT ENABLE Mode Screen
Use the RING OUT ENABLE mode screen to switch ports from the default Station (STN) status to RING OUT (RO) enable status.

uMMAC-T Local Management Flash Image Version: 01.00.01
CHASSIS STATUS VIEW ( RING OUT ENABLE ) 5 4 3 2 1 STH24 MMAC24 |---> <---| 16Mb/ 16Mb/s 1 [RO] 1 [STN] 2 [RO] 2 [STN] 3 [RO] 3 [STN] 4 [RO] 4 [STN] 5 [RO] 5 [STN] 6 [STN] 6 [RO] 7 [STN] 7 [RO] 8 [STN] 8 [RO] 9 [STN] 9 [RO] 10 [STN] 10 [RO] 11 [STN] 11 [RO] 12 [STN] 12 [RO]
NEXT [ RING OUT ENABLE ] [ REFRESH 3sec ] RETURN
Figure 4-12. CHASSIS STATUS VIEW (RING OUT ENABLE) Screen
To switch to and from STN and RO: 1. Highlight the port-status field showing STN or RO.
You can now connect the RO enabled ports to Multi-Station Access Unit (MAU) RI ports.
The COMPONENT STATUS Screen (Figure 4-13) displays the Administrative status of components operating in the MicroMMAC-T.

uMMAC-T Local Management Flash Image Version: 01.00.01
Component Name Admin. Status
Chassis Mgr enabled Local Mgmt enabled SNMP Agent enabled Protocol Stack enabled Telnet enabled RMON enabled Network 1 enabled Network 2 enabled
Figure 4-13. COMPONENT STATUS VIEW Screen
The MIB NAVIGATOR screen (Figure 4-14) provides the MIB NAVIGATOR prompt where you can issue commands for navigating and modifying the Management Information Base (MIB) structure. MIBs are the databases of objects used for managing MicroMMAC-T devices management systems.

Welcome to Cabletron MicroMMAC-T Revision 01.00.01
Figure 4-14. MIB Navigator Screen
The following sections define MIB commands and describe how to get help on using them.
To access a list of MIB commands:
Type “help” or “?” at the MIB prompt and then press the Return key.
The MIB NAVIGATOR screen appears showing the MIB Navigational and Built In commands listed in Table 4-2.
To get help on specific commands:
Type help <command> and then press the Return key.
To escape from the MIB NAVIGATOR screen:
Type either of the Special commands: done, exit, or quit at the prompt and press the Return key to return to the MAIN MENU screen.
MIBNav-> help

Table 4-2. MIB Commands
arp defroute netstat done
dir get ls ping snmp- branch
mib 2 next pw d
Navigational commands allow you to access and manage MIB objects for the device. MIB Commands are described as follows:
This command displays the object leaves of a specified directory tree.
This command changes directories within a MIB sub-tree.
This command changes directories to the Cabletron MIB.
These commands display contents of a specified sub-tree.
This command provides you with a specified object value.
This command changes directories to MIB2.

This command shows the next leaf in a path.
This command displays the full path name of the directory in which you are working.
This command lets you set the value of a managed object.
This command lets you change your community name.
This command displays an entire MIB for a device.
This command displays community name and access privileges to the MIB.
Built-In commands allow you to access and manage network devices connected to the device. Commands are described as follows:
This command lets you access the Address Resolution Protocol (arp) cache to view cache data delete entries, or add a static route.
This command lets you set the default IP route to a device through a specified interface.
This command lets you display general network statistics for a managed device.

This command let you generate an outbound ping request.
This command lets you query another SNMP device.
This command lets you query another SNMP device to obtain a value for an object.
This command lets set the values of object in other devices.
This command displays all objects and their values in a device.
This command generates a TRACEROUTE request to an IP address.
The FLASH DOWNLOAD Screen (Figure 4-15) lets you upgrade the operating image for the device.It allows you to chose a download method: RUNTIME or DOWNLOAD, to specify method-dependent options, to select a TFTP server, and to select the name and location of the image.
To download a Flash image: 1. Set values for the screen’s fields.

uMMAC-T Local Management Flash Image Version: 01.00.01
Figure 4-15. The FLASH DOWNLOAD Screen
The following sections discuss the fields on the FLASH DOWNLOAD screen and provide instructions for using them.
Use the Download Method field to select either the RUNTIME or the BOOTPROM download method. The Reboot after Download field appears when the RUNTIME method is used, and the Commit to Flash field appears when the BOOTPROM method is used.
The RUNTIME method permanently changes the image in Flash, replacing the currently stored version while the management device is operational. The process neither interrupts network operations nor affects the currently running LM application. When the device is reset, the new image takes effect.
To chose the RUNTIME method: 1. Highlight the Download Method field.
Download Method field

The Reboot after Download field appears by default when the RUNTIME method is used. If YES is selected, the MicroMMAC-T will automatically reset after the image is downloaded into Flash to load the new image into the active system file.
You can choose to use the BOOTPROM method also. It forces the device to reset and reboot from the download server rather than from the image stored in Flash.
When BOOTPROM is selected, the Commit to Flash toggle field appears, replacing the Reboot after Download field. If YES is chosen, the device will automatically replace the old image in Flash with the new image. If NO is chosen, the new image will be downloaded into active memory only, leaving the prior image in Flash unaffected and available for use at next reset. The NO option allows the user to test a new system file without losing the prior system file.
Flash Image Server IP
This read-only field shows the IP address of the most recently used file server.
Flash Image File Name
This read-only field shows the file name of the most recently downloaded image.
Use this editable field to enter the IP address of the file server containing the desired Flash image.
Use this editable field to enter the name of the file you want to download.
Download Server IP · Download File Name

TROUBLESHOOTING
This chapter describes and explains how to use LANVIEW LEDs and the Liquid Crystal Display (LCD) to troubleshoot physical layer network problems. The chapter concludes with an overview of the POWER UP Diagnostic Test.
LANVIEW LEDs (located on the front panel) are Cabletron Systems’ built-in visual diagnostic and status monitoring system. Use the LEDs to monitor network status or diagnose physical-layer network problems. Table 5-1 below lists and describes front panel LEDs.
Table 5-1. LANVIEW LEDS
Lobe Port Status (Ports 1-24)
Off Green Red Red (blinking)
No Link/Port Enabled Link/Port Enabled No Link/Port Disabled Link or Ring Speed Fault/Port Disabled
16MbpsRing Speed 4 Mbps Ring Speed
Green (Flashing) Red (Flashing) Off
Good Frames Beacon Recovery Running No Activity
Management Agent Active Management Agent Not Active
CPU (Central Processing Unit)
Off Green (Flashing) Green (Blinking) Red Yellow Yellow/Green
No Power CPU Initializing CPU Functioning (normal) CPU Not Functioning Diagnostic Testing Booting


The MicroMMAC-T is equipped with an LCD and a LCD display button as shown in Figure 5-1.
TOKEN RING HUB WITH LANVIEW® SUPPORTING 100 OHM UTP CABLE
CPU ACT MGMT 16 Mb/s COM 1 COM 2 DISPLAY RESET SPEED
The LCD is a diagnostic tool for viewing the following important status information about the MicroMMAC-T:

5.2.1 Static System Messages
Static System messages (Table 5-2) display MicroMMAC-T configuration information. To view them, press and release the Display button (Figure 5-1). Press the Display button to scroll through each message. If the Display button is not pressed again within ten seconds, the display defaults back to the product name.
Table 5-2. Static System Messages
Displays current IP address. This can be changed via Local Management
xxx.xxx.xxx.xxx
Displays Hardware or MAC address
xx.xx.xx.xx.xx.xx
Displays currently executing image
Rev. xx.xx.xx
Displays internal Boot PROM version number
Rev. xx.xx.xx
Displays number of times Flash EEPROM has been programmed.
Displays COM 1 Port’s current Baud rate
Displays COM 1 Port’s current function (Local Management console, UPS, or SLIP)
Displays COM 2 Port’s current Baud rate
Displays COM 1 Port’s current function

5.2.2 Alarm Messages
Alarm messages (Table 5-3) describe events that occur within the MicroMMAC-T. To view the Alarm Messages queue, press the Display button (Figure 5-1) and hold for five seconds. Press the Display button to scroll through each message. If the Display button is not pressed again within ten seconds, the display defaults back to the product name.
Table 5-3. Alarm Messages
No alarm messages in queue. This is the Alarm Messages default setting.
TPIM
TPIM inserted into RI or RO.
TPIM removed from RI or RO.
The x Stack inserted (where x is any value from 2 to 5).
The x Stack removed (where x is any value from 2 to 5).
Stack x Port xx
Indicates unauthorized attempt to access net work lobe ports.
uMMACT Port xx Violation
Indicates unauthorized attempt to access network lobe ports.
Indicates a station is attempting to recover from a hardware problem on the ring.
Indicates the ring has recovered from a beaconing situation.
uMMACT Port xx Removed
Indicates that a station has been removed from the ring as a result of the beacon recovery process

Table 5-3. Alarm Messages (Cont.)
Stack x Port xx
Indicates that a station has been removed from the ring as a result of the beacon recovery process
Ring Port xx wrapped
Indicates a TPIM RI or RO has Autowrapped.
Indicates that the Eagle chip set is automatically being reinserted.
Indicates that the network has been in and out of a beaconing state several times.
Unsaved intialization messages appear on the LCD as the event occurs, but are not saved in a buffer for future recall. Table 5-4 lists unsaved failure or error messages (If Failure or Error Messages appear, call your Cabletron Technical Support representative.), and Table 5-5 lists normal unsaved initialization messages.
Table 5-4. Unsaved Failure or Error Messages

Table 5-5. Normal Unsaved Initialization Messages
Saved System Message are device-related start-up or boot strap messages, BOOTP/TFTP host, or start-up error messages as shown in Table 5-6. To access the Saved System Messages queue, enter the Saved Alarm Messages queue. While in the Alarm Messages queue, press the Display button and hold for two seconds. Scroll through each message by pressing the Display button. If the Display button is not pressed again for ten seconds, the LCD defaults to the product name.
Table 5-6. Saved System Messages
Messages · Displayed Message

5.3 VIEWING POWER UP DIAGNOSTIC TESTS
The MicroMMAC-T runs from BootPROM comprehensive booting and diagnostic tests of the device whenever it has been started or reset. You can view a chronicle of the tests and any error condition messages they produce by connecting your terminal to the COM 2 port of the MicroMMAC-T. BootPROM loads the test image into Flash at the completion of the test, which lasts approximately two minutes.
The testing process generates information and displays it on your terminal. The only time you can issue commands controlling the display of the information is when an error condition has been discovered.
Figure 5-2 shows the opening test information sequence of the POWER UP DIAGNOSTIC screen depicting an error condition message with response options that are discussed below.
POWER UP DIAGNOSTIC register tests memory tests SCC COM 1 tests SCC COM 2 tests T.R. adapter tests
Do you wish to continue, retry, or loop (c, r, or l)?
P.O.Box 5005 Rochester, NH 03866-5005
Figure 5-2. POWER UP DIAGNOSTIC screen
Responding to Error Messages
Error messages provide you with three response options:
CABLETRON Systems, Incorporated · MicroMMAC-T Diagnostic/Boot Display

Choosing continue, or c, lets you proceed with the remainder of the diagnostic test. Choosing retry, or r, lets you repeat the test that produced the error message. Choosing loop, or l, lets you continuously repeat the test that produced the error message until you decide to stop it by pressing the Delete key.
To execute a response option:
Type an option letter at the prompt located at the end of the response option question and then press the Return key.
To return to Local Management:
Press the Return key.

The main cord used with this equipment must be a 2 conductor plus ground type with minimum 0.75 mm square conductors and must incorporate a standard IEC appliance coupler on one end and a mains plug on the other end which is suitable for the use and application of the product and that is approved for use in the country of application.
Die Netzleitung, die mit diesem Geraet benuetzt wird, soll einen zwei Leiter mit Erdleiter haben, wobei die Leiter mindestens 0.75 mm sind, mit einer normalen IEC Geraetesteckdose an einem Ende und einem Geraetestecker am anderen Ende versehen sind, der fuer den Gebrauch und die Anwendung des Geraetes geeignet und der zum Benuetzen im Lande der Anwendung anerkannt ist.
El cable principal de la red eléctrica utilizado con este equipo debe tener 2 conductores y 1 toma de tierra con un mínimo de 0.75 mm2 cada uno y necesita tener un aparato de acoplamiento standard IEC en un extremo y un enchufe para el cable principal de la red eléctrica en el otro extremo, lo cual sea adecuado para el uso y applicación del producto y lo cual sea aprobado para uso en el pais de applicación.
Le cordon d' alimentation reliant cet appareil au secteur doit obligatoirement avoir deux fils conducteurs de 0.75 mm2 minimum et un fil de terre. It doit également être équipé du côté appareil d'une fiche agrée IEC et du côte secteur, d'une prise adaptée à l'usage du produit et aux normes du pays où l'appareil est utilisé.
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| IS4 | You can enter values from the range specified in the parentheses | p.67 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.