EN
Bunn logo
Official user manual

Bunn JDF-2S

24 pages·3.4 MB·Beverage Dispenser·PDF·ENDEFRITNLJA
Bunn JDF-2S
Table of Contents 49 sections JDF-2S · Silver Series · INSTALLATION & OPERATING MANUAL · BUNN-O-MATIC CORPORATION · … ShowHide
Page 1 of the Bunn JDF-2S user manual — BUNN-O-MATIC CORPORATION
Page 1 · click to enlarge
Page 1

JDF-2S

Silver Series

Bunn JDF-2S — JDF-2S diagram (page 1)
Fig. 1

INSTALLATION & OPERATING MANUAL

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644

To obtain the Illustrated Parts Catalog, visit the Bunn-O-Matic website, at www.bunn.com This is absolutely FREE, and the quickest way to obtain the catalog. Contact Buun-O-Matic Corporation at 1-800-286-6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.

www.bunn.com 38945.0000F 01/07 ©2006 Bunn-O-Matic Corporation

Page 2 of the Bunn JDF-2S user manual — BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Page 2 · click to enlarge
Page 2

CONTENTS Introduction & Warranty 2 User Notices 3 Initial Set-Up & Electrical Requirements 4 Plumbing Requirements 4 Door Cover Installation 5 Plumbing Hookup 6 Initial Fill 6 Loading & Priming 7 Operating Controls 8 Dispenser Use 8 Cleaning 10 Adjustments & Optional Settings 12 Function Lists 15 Troubleshooting 16 Coolant Diagram 22 Schematic Wiring Diagram 23 Quick Setup Guide 24

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY

Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first. These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment. THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.

BUNN, JDF-2S and JDF-2SA are either trademarks or registered trademarks of Bunn-O-Matic Corporation.

· 38945 061506

Page 3 of the Bunn JDF-2S user manual — USER NOTICES
Page 3 · click to enlarge
Page 3

USER NOTICES

Carefully read and follow all notices on the equipment and in this manual. They were written for your protec tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.

Bunn JDF-2S — USER NOTICES diagram (page 3)
Fig. 2

27442.0000 00986.0002

33461.0001

Page 4 of the Bunn JDF-2S user manual — PLUMBING REQUIREMENTS
Page 4 · click to enlarge
Page 4

INITIAL SET-UP

Set the dispenser on the counter where it will be used. The JDF-2S requires a minimum of 4 inches (102 mm) of air clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is required between the dispenser sides and the wall or another appliance. For optimum performance, do not let warm air from surrounding machines blow on the JDF-2S. Leave some space so the dispenser can be moved for cleaning.

ELECTRICAL REQUIREMENTS

CAUTION: The dispenser must be disconnected from the power source until specified in Electrical Hook-Up. The 120V rated dispensers have an attached cord set and require a 2-wire, grounded, individual branch circuit rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R. The 230V rated dispenser has an attached cord set and requires an attachment plug cap rated at least 230 volts ac, 15 amp. The attachment plug cap must meet with applicable national/local electrical codes. Refer to the data plate for exact electrical requirements.

ELECTRICAL HOOK-UP CAUTION: Improper electrical installation will damage electronic components.

1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source. 3. Confirm that the refrigeration switch on the rear of the dispenser is in the OFF position. 4. Connect the dispenser to the power source. 5. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumb ing has been hooked up, the dispenser is ready for Initial Fill.

PLUMBING REQUIREMENTS

This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second. A shut off valve should be installed in the line before the dispenser. Install a regu lator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The regulator is also necessary if the water source has pressure fluxuations. The main water inlet is a 3/8” (9.52 mm) MFL connection. NOTE- At least 18 inches (457 mm) of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene, before the dispenser will facilitate movement to clean the countertop. It can be purchased direct from BUNN-O-MATIC (part number 34325.10_ _ [see Illustrated Parts Catalog for complete part number.]) BUNN-O-MATIC does not recommend the use of saddle valves to install the dispenser. The size and shape of the hole(s) made in the supply line(s) by saddle valves may restrict water flow.

This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., you must comply with the applicable Plumbing/Sanitation Code for your area.

· 38945 061506

Page 5 of the Bunn JDF-2S user manual — P3579
Page 5 · click to enlarge
Page 5

DOOR COVER INSTALLATION

Bunn JDF-2S — DOOR COVER INSTALLATION diagram (page 5)
Fig. 3
1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door.

P3577

Bunn JDF-2S — P3577 diagram (page 5)
Fig. 4
2. Install door cover.

P3578

Bunn JDF-2S — P3578 diagram (page 5)
Fig. 5
3. Secure the door cover using 5 screws provided.

P3579

· 38945 031406

Page 6 of the Bunn JDF-2S user manual — P3582
Page 6 · click to enlarge
Page 6

PLUMBING HOOKUP The plumbing connection is located on the rear of the dispenser. A 3/8” (9.52 mm) male flare adapter fitting is supplied, installed on the rear of the dispenser.

Bunn JDF-2S — P3580-1 diagram (page 6)
Fig. 6

FIG 1 Plumbing Connections

P3580-1

INITIAL FILL CAUTIONThe dispenser must be disconnected from the
Bunn JDF-2S — P3580-1 diagram (page 6)
Fig. 7

power source throughout the initial fill except when speci fied in the instructions. 1. Remove drip tray assembly and splash panel from the dispenser. Replace the drip tray. 2. Connect the water source to the back of the dispenser. 3. Pull the fill tube from the dispenser, remove the plug and connect it to the dispense nozzle. 4. Place the Dispense Lockout switch in the OFF position. 5. Connect dispenser to the power source. Press and hold the dispense button for the dispense station that the tube is connected to for 10 seconds, until you hear the water valve turn on. 6. Monitor the water bath fill level until water starts to trickle from the overflow tube. Then press the dispense button again to stop the fill process. 7. Turn ON the refrigeration switch at the back of the dis penser. This will start the water bath pump circulation. 8. Check water level in the overflow tube and top off the tank if necessary (Step 5). 9. Disconnect the fill tube and allow excess water to drain into the drip tray. Replace the plug in the end of the fill tube and store back into the dispenser. 10. Place the Dispense Lockout switch back to the ON posi tion. 11. Replace the splash panel and drip tray. 12. It will take approximately three hours at 75° F (24° C) ambient to create the ice bank required for full dispenser performance. During this time, some further trickling from the water bath is expected due to expansion caused by ice bank formation. While the refrigeration system is creating the ice bank, the dispenser may be readied for use as described in Loading, Priming and Adjustment.

FIG 2 Initial Fill Hose

P3581-1

Bunn JDF-2S — P3581-1 diagram (page 6)
Fig. 8

FIG 3 Initial Fill Connection

P3582

· 38945 050106

Page 7 of the Bunn JDF-2S user manual — LOADING
Page 7 · click to enlarge
Page 7

LOADING

Frozen Concentrates 1. Thaw the frozen concentrate in a refrigerated 35-40 degrees F (1.6-4.4 degrees C) environment for 36 to 48 hours before use. 2. Thoroughly mix the thawed concentrate by vigorously shaking the product container. 3. Open the dispenser door. 4. Prior to placing the product container in the dispenser, make sure that the o-ring on the container adapter is lubricated. This will ease removal of the container when it becomes necessary. 5. Place the product container in the desired position and press it firmly into the bottle adapter opening. 6. Open the vent hole in the product container.

Ambient Concentrates (Optional) 1. Install an Ambient Concentrate Conversion Kit (BUNN-O-MATIC part number 33699.0001) per the instruc tions provided in the kit. 2. Attach the concentrate product hose to the appropriate concentrate line located at the rear of the dispens er. 3. Attach the other end of the product hose to the product container through an appropriate fitting.

PRIMING 1. Open the dispenser door 2. Load concentrate per instructions in section titled Loading. 3. Close the dispenser door. 4. Place a large container under the appropriate dispense nozzle. Press and hold the “Product Dispense Switch” Fig 5, until concentrate dispenses from the dispense nozzle. Note: This may take several seconds, depending on the installation and set pump speed.

· 38945 031406

Page 8 of the Bunn JDF-2S user manual — DISPENSER USE
Page 8 · click to enlarge
Page 8

OPERATING CONTROLS

Refrigeration Switch The refrigeration switch is located on the rear of the dispenser near the center. This switch controls power to the water bath pump and relay contacts for the compressor and condenser fan motor.

FIG 4 Refrigeration Switch

P3580-1

Bunn JDF-2S — P3580-1 diagram (page 8)
Fig. 9
Bunn JDF-2S — P3580-1 diagram (page 8)
Fig. 10

FIG 6 P3583 P3612

FIG 5

A. Product Dispense Switch Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow. B. Dispense Lockout Switch This switch is located at the bottom front of the dispenser just behind the drip tray. It is used to turn ON and OFF the Dispensing function. It is also used for some programming and fill procedures.

DISPENSER USE

Press and Hold Dispensing: 1. Place a cup on the drip tray beneath the desired dispensing nozzle. 2. Press and hold the “Product Dispense” switch until the beverage reaches the desired level, then release.

· 38945 050106

Page 9 of the Bunn JDF-2S user manual — P3585 FIG 7
Page 9 · click to enlarge
Page 9

OPERATING CONTROLS (Continued)

Portion Control Option The JDF-2S dispenser is also equipped with a portion control option. The following steps will guide you through the set up process for this option. Portion control can be set on one or all dispense heads as needed. 1. Unplug dispenser from power source. 2. Place Dispense Lockout switch in the OFF position. 3. Remove drip tray and splash panel from the front of the machine then replace the drip tray. 4. Press and hold either dispense switch while plugging the dispenser into the power source. Continue hold ing dispense switch until all 4 temperature LED’s, Fig. 7 on the circuit board start flashing slowly (this takes about 5 seconds). Release dispense switch. 5. Press and release either dispense switch 6 times to enter the portion control set up mode. This will cause the 4 temperature LED’s to flash rapidly. 6. Place a container under the desired dispense nozzle to measure the portion size. 7. Press and hold the desired dispense switch to dispense product until the desired amount of product is achieved. (Maximum dispense time is 25 seconds). Repeat this on all dispense heads as desired. 8. Place Dispense Lockout switch back into the ON position. This will exit the Portion control set up mode. 9. Place a container under the dispense nozzle and press the dispense button to confirm that the portion size is set correctly. Repeat steps 1-8 if any changes are needed. 10. Replace splash panel.

Procedure to return all dispense heads back to Push and Hold mode: 1. Unplug dispenser from power source. 2. Place Dispense Lockout switch in the OFF position. 3. Remove drip tray and splash panel from the front of the machine then replace the drip tray. 4. Press and hold either dispense switch while plugging the dispenser into the power source. Continue holding dispense switch until all 4 temperature LED’s on the circuit board start flashing slowly (this takes about 5 seconds). Release dispense switch. 5. Press and release either dispense switch three times. 6. Place Dispense Lockout switch back into the ON position. 7. Replace splash panel and drip tray. 8. Place a container under each dispense nozzle and press dispense buttons to confirm machine is operating in push and hold mode.

Bunn JDF-2S — OPERATING CONTROLS (Continued) diagram (page 9)
Fig. 11 · OPERATING CONTROLS (Continued)

P3585 FIG 7

· 38945 050106

Page 10 of the Bunn JDF-2S user manual — CLEANING & PREVENTIVE MAINTENANCE
Page 10 · click to enlarge
Page 10

CLEANING & PREVENTIVE MAINTENANCE

DailyRinse Procedure Tools required: 32 oz. (946 ml) minimum empty container
1. Open refrigerated compartment door and remove product containers. 2. Fill a clean container with warm water and place the container into the cabinet and press it firmly into the bottle adapter opening. 3. Close the door, place an empty container under the dispensing nozzle and press the dispense switch until clear water flows from the dispense nozzle. 4. Repeat steps 1 - 3 for all dispense stations.

Daily: Parts Washing 1. Remove and wash the dispense nozzle(s), mixing element(s), drip tray and drip tray cover in a mild detergent solution. Rinse thoroughly. 2. Wipe splash panel, areas around dispense nozzle(s), and refrigerated compartment with a clean, damp cloth.

Weekly: Semi-Automatic Sanitize Process Tools required: 1 empty 5 gallon (18.9 L) bucket, 2 packets of Kay 5 sanitizer, and clean, empty concentrate container.

1. Remove all concentrate from the dispenser and store in a separate refrigerated compartment. 2. Fill clean empty concentrate container(s) with approximately 32 oz. (946 ml) of hot tap water (approximately 140 Deg. F (60 Deg. C). Load the containers of hot water into the dispenser (just like concentrate). 3. Place an empty container under the dispense nozzles. 4. Press and hold the dispense button at each station until the stream out of the nozzles runs clear (about 30 seconds). Note: the dispenser will not allow both stations to run at the same time. 5. Once this is completed, remove the container(s) and empty. 6. Remove each dispense nozzle and mixing element and run under hot tap water to remove excess pulp. 7. Prepare 2.5 gal. (9.46 L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gal. (9.46 L) of 120 Deg F (48.9 Deg. C) water to ensure 100 ppm of available chlorine. 8. Place nozzle(s) and mixing element(s) in a separate 1-quart container of sanitizing solutions and mix thor oughly. Allow the parts to soak for 2 minutes. 9. Clean the dispense nozzle receptacle(s) (dispense valves) with the sanitizing solution and a soft bristle brush. 10. Clean the concentrate bottle’s inlet adapter(s) using the sanitizing solution and a soft bristle brush. 11. Replace the mixing element(s) and nozzle(s). 12. Fill approximately 128 ounces (3.8 L) of clean sanitizing solution into clean, empty concentrate container(s). Do not use the sanitizing solution used in step 10. Load the container(s) into the dispenser. 13. Place a large empty container under each dispense nozzle. 14. Press and hold both dispense buttons for about 10 seconds to initiate the sanitize cycle. The cycle will start with only one of the dispense stations dispensing. Note: The cycle will consist of a 1 minute dispense time (alternating) on each station, then 5 minutes of soak time, then a 2 minute dispense time (alternating) on each station. 15. When the above cycle is complete, Remove the sanitizing solution and replace with concentrate. 16. At each station, press and hold the dispense switch until product appears. Then dispense one 12 ounce (354.9 ml) glass of finished product and discard. 17. Wipe internal and external surfaces with a clean, damp cloth.

38945 090606

Page 11 of the Bunn JDF-2S user manual — CLEANING & PREVENTIVE MAINTENANCE
Page 11 · click to enlarge
Page 11

Monthly: Clean Condenser Coils 1. Use a soft bristle brush to clean the build up of dirt in the condenser.

AnnuallyReplace Pump Tubing

1. Open dispenser door. 2. Remove all product containers and place them in a refrigerated (35-40 degrees F [1.6-4.4 degrees C]) envi ronment. Disconnect all connections to ambient products from the bottle adapter. 3. Rinse all dispense stations using steps outlined in “DAILY RINSE PROCEDURE”. 4. Disconnect dispenser from power source. 5. Remove the dispense platform cover. 6. Disconnect the dispense platform water line from the supply line inside the refrigerated cabinet and discon nect the wiring connection from the cabinet receptacle. 7. Remove the mounting screw securing the dispense platform to the cabinet . 8. Pull the dispense platform completely out of the cabinet and place it on a flat work surface. 9. Close the dispenser door. 10. Remove the 4 screws securing the pump head. 11. Gently pull the pump head apart. 12. Gently pull the pump tube from around the pump’s rotor. 13. Release the clamps securing the old pump tubing to the plastic elbows. 14. Pull the plastic elbows from the old pump tubing, and discard the old pump tubing. 15. Insert the plastic elbows into the new pump tubing and secure it with the clamps. 16. Gently wrap the new pump tubing around the pump’s rotor. 17. Reassemble the pump housing onto the platform assembly. 18. Repeat steps 10 through 17 for the remaining pump. 19. Replace the dispense platform into the refrigerated cabinet, making sure to reconnect all electrical and water connections. 20. Replace the dispense platform cover. 21. Turn power on to dispenser. 22 Install containers of rinse water, run each station and check for leaks. Repair leaks as necessary. 23. Replace product shelf and product containers. Reconnect any connections to ambient product containers. 24. Prime the pumps as described in “PRIMING” in the Initial Fill Section.

CLEANING (cont) · 38945 012207

Page 12 of the Bunn JDF-2S user manual — P3586
Page 12 · click to enlarge
Page 12

ADJUSTMENT & OPTIONAL SETTINGS

Water Flow Testing and Adjustment 1. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the ap propriate dispense nozzle. Place the Dispense Lockout switch in the OFF position. 2. Press and release the desired “Product Dispense Switch” three times. 3. The selected position will dispense water (no concentrate) only for 3 seconds. 4. Measure the water dispensed. 5. Adjust the water flow rate Fig 8, (clockwise to increase flow rate; coun terclockwise to decrease flow rate) to the corresponding product mix ratio as follows:

P3586

FIG 8 Adjusting Water Flow

Using 1/4” allen wrench

Mix Ratio (water + concentrate)Adjust water flow rate to:ProductBrix % 2+1*3.75 fl. oz (111 ml) per 3-second testPrune Juice16.0% Other* 4+1*4.0 fl. oz (118 ml) per 3-second testOrange Juice11.8% Pineapple Juice12.8% Cranberry Fruit Cocktail14.0% 5+1Grapefruit Juice10.6% Lemonade Apple Juice12.0% Fruit Punch Grape Juice13.0% 3+1 through 7+1Other* Above 7+1*4.0 fl. oz (118 ml) per 3-second testOther* High Viscosity Juice2.25 - 3.0 fl. oz (66.5 - 89 ml) per 3-second testAs Required-
6. Repeat steps 1 through 5 as necessary until the correct water flow rate is achieved. 7. Repeat steps 1 through 5 for the remaining dispense positions. 8. Place the Dispense Lockout switch back into the ON position.

Pump Speed Adjustment 1. Disconnect the dispenser from the power source. 2. Remove the drip tray. 3. Remove the two screws securing the splash panel and remove the splash panel 4. Locate the adjustment knobs on the circuit board. 5. Turn the adjustment knobs clockwise to increase speed and counterclockwise to decrease speed. 6. The left knob adjusts the left dispense station and the right knob adjusts the right station. 7. Reinstall the splash panel and drip tray and reconnect the dispenser to the power source.

38945 050106

Page 13 of the Bunn JDF-2S user manual — OZ
Page 13 · click to enlarge
Page 13

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Total Dispense Ratio Set Up Procedure 1. Adjust water flow as described in Water Flow Testing and Adjustment. Record water output setting for later reference on each dispense head. 2. Place the Dispense Lockout switch in the OFF position. 3. Place a measuring container under the dispense nozzle, press and release the DISPENSE button 6 times. 4. Record the total ounces dispensed. 5. Refer to the Brix/Ratio chart below to confirm proper total dispensed amount for ratio desired and water output previously recorded. 6. To increase or decrease the product output, refer to Pump Speed Adjustment section. 7. Place the Dispense Lockout switch back into the ON position.

SECOND WATERDISPENSE

2ATIO4ARGET

OZ

$ISPENSEDPRODUCTOZ

Temperature Compensated Refractometer Method 1. Adjust the water flow as described in Water Flow Testing and Adjustment. 2. Place an empty container under the appropriate dispense nozzle. 3. Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from the dispense nozzle. 4. Discard the product caught previously and place the empty container back under the dispense nozzle. 5. Press and hold the “Product Dispense Switch” until the cup is filled. 6. Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions) to check the brix %. 7. Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the correct brix % as described in Pump Speed Adjustment.

38945 050106

Page 14 of the Bunn JDF-2S user manual — SECOND WATERDISPENSE
Page 14 · click to enlarge
Page 14

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Dispenser Lockout Dispense functions of the dispenser can be turned-off to prevent unauthorized use of the dispenser, while keeping the refrigeration system running.

1. Locate the Dispense Lockout switch at the bottom front of the dispenser behind the drip tray. 2. Place the switch in the OFF position to prevent dispensing. 3. Place the switch in the ON position to allow dispensing.

38945 050106

Page 15 of the Bunn JDF-2S user manual — P3585 FIG 9
Page 15 · click to enlarge
Page 15

FUNCTION LIST

Circuit Board LED Indicators

LED # LED Color Illuminates: 1 Green When the compressor should be ON. 2 Cabinet Red When the cabinet temperature is above 50 degrees F. Flashes slowly when cabinet temperature exceeds 50 degrees F for 4 hours. Dispense functions are locked out under this condition. Power down the dispenser to reset.

Flashes rapidly if dispense is attempted in lockout condition.

Open cabinet thermistor circuit will flash #2 and #3 LED’s 1 time every 3 seconds.

Shorted cabinet thermistor will turn #2 and #3 LED’s on steady. 3 Cabinet Green When cabinet temperature is below 50 degrees F. 4 Bath Red When bath temperature is above 34 degrees F. Flashes slowly when compressor is in a 6 minute delay period.

Open bath thermistor circuit will flash #4 and #5 LED’s 1 time every 3 seconds. The compressor will not run under this condition.

Shorted bath thermistor circuit will flash #4 and #5 LED’s 2 times every 3 seconds. The compressor will not run under this condition. 5 Bath Green When bath temperature is below 34 degrees F.

P3585 FIG 9

38945 031406

Page 16 of the Bunn JDF-2S user manual — PROBLEM PROBABLE CAUSE REMEDY
Page 16 · click to enlarge
Page 16

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.

  • Inspection, testing, and repair of electrical equipment should be performed only by qualified service person nel.
  • All electronic components have 120-240 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the application of external voltages may result in board failure.
  • Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a terminal or crimp.
  • Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water.
  • The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help to avoid twists and kinks in the tubing.
  • Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
  • WARNING –
  • Exercise extreme caution when servicing electrical equipment.
  • Unplug the dispenser when servicing, except when electrical tests are specified.
  • Follow recommended service procedures.
  • Replace all protective shields or safety notices.

PROBLEM PROBABLE CAUSE REMEDY

Cold Water Circulation Dispense stations not working. Note: Cooling failure or excessive cabinet temperatures for more than 4 hours will result in dispense lockout or no dispense. Note: Reset fault/timer by unplug ging unit.

1. Cabinet cooling fan.

Replace fan (24vdc). Note: Fan receives power when the dispenser is powered.

2. Bath recirculation pump.

A) If not running, check refrigera tion switch and wiring for proper continuity.

B) Check for 120V or 230V AC at pump. Replace pump.

3. Restricted water flow to cabinet water coil and bath.

Check for kinked hose.

38945 061506

Page 17 of the Bunn JDF-2S user manual — PROBLEM PROBABLE CAUSE REMEDY
Page 17 · click to enlarge
Page 17

TROUBLESHOOTING (cont.)

PROBLEM PROBABLE CAUSE REMEDY

Refrigeration Dispense stations not working. Note: Cooling failure or excessive bath and cabinet temperatures for more than 4 hours will result in dispense lockout or no dispense.

1. Compressor ON/OFF switch.

Check for "ON" position or no con tinuity - replace switch.

2. Dirty condenser filter or fins.

Clean filter and fins or replace con denser filter. (Filter not supplied on some machines).

3. Condenser fan not running.

A) Check for 120V or 230V AC. Re place fan motor or check fan blades for obstructions.

B) Check compressor LED on circuit board. If ON, relay coil should have power (120 or 230 VAC).

4. Compressor relay not activat ing.

Check compressor relay coil for 120 or 230vac. NOTE: Always check power with coil attached. If compressor LED is ON and no 120 or 230vac - re place board. If yes, 120 or 230vac - replace relay. Note: Relay contacts are normally open.

5. Compressor not running.

Check compressor thermal overload (N/C). If open check for dirty con denser filter or adequate ventilation and space around machine.

6. Compressor running and not cooling.

Check refrigeration system for leaks and proper charge.

Dispenser Locked Out Dispense stations not working.

1. Check Dispense Lockout switch.

(A) Set switch to ON position.

(B) Check switch and harness for proper continuity.

Cooling system failure.

1. Refrigeration or cold water recir culation system.

Check all previous items that pre tain to refrigeration or cold water recirculation

38945 061506

Page 18 of the Bunn JDF-2S user manual — PROBLEM PROBABLE CAUSE REMEDY
Page 18 · click to enlarge
Page 18

TROUBLESHOOTING (cont.)

PROBLEM PROBABLE CAUSE REMEDY

Dispense station not working

1. Dispense Lockout switch set to OFF position.

Place switch in ON position.

2. Dispense switch failed

Check switch and harness for proper continuity.

All stations dispense concentrate only

Check for ON position.

A) Compressor relay/contacts shorted - replace relay.

B) Recirculating pump - replace or check for kinked flex line.

Inlet water valve failed

A) Check for 120V or 230V power when dispensing. If yes, replace valve. If no, check harness for proper continuity. Then replace circuit board if needed.

Main water supply · Frozen bath · 38945 061506

Page 19 of the Bunn JDF-2S user manual — PROBLEM PROBABLE CAUSE REMEDY
Page 19 · click to enlarge
Page 19

TROUBLESHOOTING (cont.)

PROBLEM PROBABLE CAUSE REMEDY

Dispense station concentrate only

Replace solenoid (24vdc) or check wire connection between water valve and main control board.

Dispense station water only

Replace refill concentrate container or BIB

Product pump not pumping

Check for proper counterclockwise rotation of pump rollers. If coun terclockwise, replace pump tubing. If clockwise, wire connection to pump is reversed. Switch wires on terminals.

A) Check speed setting on circuit board and increase speed (turn clockwise)

B) Check for d.c. power to pump motor. If yes, replace motor assy. If no, check harness for proper con tinuity. Then replace circuit board if needed.

Show 4 more labels / short text on this page
Water solenoid · Concentrate out · Pump not turning · 38945 031406
Page 20 of the Bunn JDF-2S user manual — PROBLEM PROBABLE CAUSE REMEDY
Page 20 · click to enlarge
Page 20

TROUBLESHOOTING (cont.)

PROBLEM PROBABLE CAUSE REMEDY

Water leak filling drip tray or around dispense deck area

1. Initial fill/setup

Some expansion normal. May fill drip tray during initial ice block formation

2. Dispense deck

Inspect or replace fittings clamps, o-rings, solenoids and quick discon nect fittings. NOTE: Dispense deck area slopes to drain tube that leads to the drip tray.

3. Water pressure greater than 100psi

Install water pressure regulator and reduce to 50 psi.

Water leaking beneath machine

1. Bath tank overflow.

A) Check all internal water connec tions.

B) Check internal plumbing con nections.

2. Condensation from cabinet cool ing coil.

Check for routing of condensation tube to water bath.

Erratic spray during dispense

Dispense nozzle mixer missing or broken

Replace mixer.

Dispense nozzle dripping water

Dispense solenoid.

Replace dispense deck solenoid.

38945 031406

Page 21 of the Bunn JDF-2S user manual — PROBLEM PROBABLE CAUSE REMEDY
Page 21 · click to enlarge
Page 21

TROUBLESHOOTING (cont.)

PROBLEM PROBABLE CAUSE REMEDY

Unit is not working

1. Step-down transformer.

Check for 120/24 or 230/24 vac. If no 24vac reading, replace step-down transformer.

2. Main control board.

If 24 vac present and no LED’s lit, replace control board..

Difficulty brixing and/or weak bev erage

1. Product viscosity or too cold.

Thorough thaw of product before use (35° - 40°)

2. Low water pressure.

Maintain 20 psi or higher and a minimum flow rate of 3 fl oz/sec.

3. High water pressure.

Over 100 psi, install a pressure regulator and set to 50 psi.

4. Dispense valve adjustment set ting.

A) Perform 3 second water dispense test. Factory setting is 1.0 oz/sec. Acceptable water flow rate is .-0.8 to 1.5 oz/sec depending on the mix ratio (4+1).

B) Adjust water to proper mix ratio. Once water is set, adjust motor speed to achieve brix %.

5. Brix ratio.

Check for proper brix ratio per prod uct using Total Dispense method and or refractometer method.

Difficulty brixing and/or weak bev erage

1. Pump tubing.

Inspect, clean, or replace tubing and pump rotor/rollers for ease of rotation.

2. Use of portable water pump.

A) Follow plumbing requirements for pressure and flow rate.

B) Source another portable pump or water supply that meets require ments.

Inspect all lines and connections from bag-in-box connector to bottle adapter assembly.

Difficulty brixing bag-in-box · Vacuum leak · 38945 061506

Page 22 of the Bunn JDF-2S user manual — PROCESS TUBE
Page 22 · click to enlarge
Page 22

COOLANT SCHEMATIC DIAGRAM

PROCESS TUBE

EVAPORATOR

ACCUMULATOR COMPRESSOR

SUCTION

FILTER

DRYER

CONDENSER

38945 031406

Page 23 of the Bunn JDF-2S user manual — SCHEMATIC WIRING DIAGRAM JDF-2S
Page 23 · click to enlarge
Page 23

SCHEMATIC WIRING DIAGRAM JDF-2S

120V MODELS

230V MODELS

Bunn JDF-2S — SCHEMATIC WIRING DIAGRAM JDF-2S diagram (page 23)
Fig. 12

120 VOLTS AC or 230 VOLTS AC 2 WIRE SINGLE PHASE

23 38945 121906

Page 24 of the Bunn JDF-2S user manual — P3591 P3590-1
Page 24 · click to enlarge
Page 24

QUICK SETUP GUIDE

Bunn JDF-2S — QUICK SETUP GUIDE diagram (page 24)
Fig. 13
Bunn JDF-2S — QUICK SETUP GUIDE diagram (page 24)
Fig. 14
Bunn JDF-2S — QUICK SETUP GUIDE diagram (page 24)
Fig. 15

P3577

1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door. 2. Install door cover. 3. Secure the door cover using 5 screws provided.

P3578 P3579

Bunn JDF-2S — P3578 P3579 diagram (page 24)
Fig. 16
Bunn JDF-2S — P3578 P3579 diagram (page 24)
Fig. 17

P3587-1 P3580-1 P3588

4. Place refrigeration switch in the OFF po sition.
5. Connect water supply to machine. (See Plumbing Requirements)
6. Connect power supply to machine. (See Electrical Requirements)
Bunn JDF-2S — P3587-1 P3580-1 P3588 diagram (page 24)
Fig. 18
Bunn JDF-2S — P3587-1 P3580-1 P3588 diagram (page 24)
Fig. 19

P3582 P3589 P3612

7. Install bath tank fill tube over a nozzle as shown. (See Initial Fill)
8. Place the Dispense Lockout switch in the OFF position.
9. Hold the dispense switch until water be gins to flow into the tank (approx. 10 sec onds). When tank is full, water will begin pour out of the overflow tube, Press the dispense button to stop the flow of water.
Bunn JDF-2S — P3582 P3589 P3612 diagram (page 24)
Fig. 20
Bunn JDF-2S — P3582 P3589 P3612 diagram (page 24)
Fig. 21
12. Proceed to page 7 in the Operating and Installation manual for calibration instruc tions and charts.

P3591 P3590-1

10. Place the refrigeration switch in the ON position.
11. Insert juice containers as shown.

38945 050106

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Bunn JDF-2S

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bunn JDF-2S

Be the first to ask — other owners or our team will answer.

Original document

Bunn JDF-2S manual PDF

24 pages·3.4 MB·Beverage Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…