READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.
This manual provides important information on proper operation & maintenance. Every effort has been
made to ensure the accuracy of this manual. These instructions are not meant to cover every possible
condition and situation that may occur. We reserve the right to change this product at any time without
prior notice.
IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE,
DO NOT RETURN THIS PRODUCT TO THE RETAILER - CONTACT CUSTOMER SERVICE.
If you experience a problem, have questions or need parts for this product, visit our website
http://www.buffalotools.com or call Customer Service at 1-888-287-6981, Monday-Friday,
8 AM - 4 PM Central Time. A copy of the sales receipt is required.
FOR CONSUMER USE ONLY – NOT FOR PROFESSIONAL USE. KEEP THIS MANUAL, SALES RECEIPT & APPLICABLE WARRANTY FOR FUTURE REFERENCE.




RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment. Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

Notice Regarding Emissions: Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine Modifications (EM). Legal Requirements: Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site. IMPORTANT SAFETY INSTRUCTIONS STOP!
Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this generator, call 1-888-287-6981, Monday - Friday, 8 AM - 4 PM Central Time.
Chemicals: According to the State of California, the exhaust from this generator contains chemicals known to cause cancer, birth defects, or other reproductive harm.







In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator.


PACKAGE CONTENTS The following items are supplied with this Model GEN154 2000 Surge Watts / 1500 Running Watts Portable Generator. Verify that all items are included. STOP!




GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator.
1 1) Fuel Tank Cap 2) Control Panel 3) Grounding Terminal 4) Oil Access 5) Recoil Starter 6) Carburetor Choke Lever 7) Fuel Cock


When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as illustrated in Figure 2.


Figure 1 – Open the Oil Access Panel Figure 2 - Adding Oil

line. The fuel tank capacity for this generator is 1.8 gallon (7 L). NOTE: Because gasoline can expand, do not fill the fuel tank to the very top.
Failure to properly ground this generator can result in electrocution. Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3. A No. 12 AWG (American Wire Gauge) stranded copper wire is generally an acceptable grounding wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth. Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

Figure 3 The Grounding Terminal is located on the front of the generator, to the right of the DC Output socket.

Subsequent Use of this Generator For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation. IMPORTANT: Be familiar with the procedures described in the previous section titled “Using the Generator for the First Time” of this manual. If not, review this section now. Step 1 - Verify Oil Level Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil, it is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity.
dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See “Changing/Adding Oil” in the
“Maintenance/Care” section of this manual).
5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level. Step 2 - Verify Gas Level Before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the top of this generator, indicates the gas level currently in the fuel tank. If necessary, add fresh unleaded gasoline with an octane rating of 87 or higher according to “Step 2 - Add Gasoline” of the “Using this Generator for the First Time” section of this manual. Model GEN154 Fuel Tank Capacity (gals /L) 1.8 / 7 Model GEN154 Fuel Type Fresh, Unleaded Gasoline Octane Rating 87 or Higher
Failure to properly ground this generator can result in electrocution. Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth. Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been correctly completed. If unsure about how to perform any of these steps, call 1-888-287-6981, Monday - Friday, 8 AM - 4 PM Central Time for customer service.
Disconnect all electrical loads from this generator before attempting to start. To start this generator:
cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.
again. If problems persist, call 1-888-287-6981, Monday - Friday, 8 AM - 4 PM Central Time.
additional 30 seconds and then move the choke lever completely over to the “open” position.

Figure 4 The Recoil Start is located on the left side of the generator.



This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage equal to or less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a generator. A device's rated (running) wattage should be listed somewhere on the device itself and/or in its manual. If the wattage specification for a device is not available, the wattage can be calculated by multiplying the Voltage requirement (120 or 240) by the Amperage drawn. Watts = Volts x Amperes Or, the wattage required by a device can be estimated by using the following chart. The chart provides only estimates and it is better to know the exact wattage of each electrical device to be powered by this generator.
Electrical Device Rated (Running) Watts Additional Surge Watts air compressor (1 - 1/2 HP) 2500 2500 airless sprayer (1/3 HP) 600 1200 coffee maker 1500 0 computer w/17 inch monitor 800 0 deep freezer 500 500 electric drill (1/2 HP) 1000 1000 furnace fan blower (1/2 HP) 800 1300 hot plate 2500 0 microwave oven (1000 watt) 1000 0 quartz halogen work light 1000 0 refrigerator/freezer (18 Cu. Ft.) 800 1600 saw - circular (7 1/4 inch) 1500 1500 stereo receiver 450 0 electric stove - single element 1500 0 sump pump 800 1200 television (27 inch color) 500 0 well water pump (1/3 HP) 1000 2000 window air conditioner (10000 BTU) 1200 1800 window fan 300 600
Connect electrical devices to this generator according to the following procedure: Allow the engine to run for several minutes after it has been started. Confirm that the electrical device is switched off prior to plugging it into this generator.

Connect only electrical devices that are in good working order. Faulty devices or power cords present the risk of electrical shock. Immediately turn off and disconnect any device that commences to operate abnormally, sluggish or abruptly stops. Determine if the problem was the device or the rated load capacity of this generator has been exceeded. NOTE: Plug appliances into the correct outlet. Connect standard 120 Volt, single phase, 60 Hz loads to the 120 Volt outlet. Connect 12 Volt, DC loads to the 12 Volt outlet.
Even though this generator has an overall rated wattage of 1100, do not attempt to draw more than 1300 Watts from the 120 Volt outlet. Draws higher than 1300 Watts will damage this generator and void the warranty.
with the next lower rated wattage requirement.
Do not connect 50Hz or 3-phase loads to this generator.

SOME NOTES ABOUT POWER CORDS Long or thin cords can require more wattage from a generator to power an electrical device. Figure 6 shows the recommended cords according to the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly higher rated wattage requirement.

Device Requirements Max. Cord Length (ft) by Wire Gauge Amps Watts (120V) Watts (240V) #8 wire #10 wire #12 wire #14 wire #16 wire 2.5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7.5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15 1800 3600 NR 150 100 65 NR 20 2400 4800 175 125 75 50 NR 25 3000 6000 150 100 60 NR NR 30 3600 7200 125 65 NR NR NR 40 4800 9600 90 NR = Not Recommended.

The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet.
Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator.
Failing to use the correct procedure can cause a battery to explode, seriously injuring anyone nearby. Keep heat, sparks, flame and smoking materials away from the battery. To connect 12 Volt batteries to the DC outlet:

Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency.


Allow this generator to cool down before touching areas that become hot during operation.
Allowing gasoline to sit in this generator's fuel tank for extended time without use can increase the difficulty in starting this generator in the future. Never store this generator for extended time with gasoline in the fuel tank. MAINTENANCE/CARE Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 7.

Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance procedures. Keep heat, sparks and flame away.
Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual. Recommended Maintenance Schedule
Every Year or Each 300 Hrs Engine Oil Check Level X Replace X Air Filter Check X Clean X Fuel Filler Cap Clean X Spark Plug Check/Clean X Fuel Tank Verify Gas Level X Clean X Figure 7 - Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, vacuum and/or pressurized air. Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion. Never use gasoline to clean parts of this generator.


Checking the Oil Level It is important to check the oil level in the engine crankcase before each use to ensure that there is a sufficient quantity. To check the oil level:
visible only at the very end of the dipstick, add oil until the engine crankcase is filled.
5. Confirm that the oil filler/dipstick cap is properly in place when finished verifying the oil level. Changing/Adding Oil The oil level in this generator should be checked before each use. (See Figure 9.) When the oil level is low, add oil until the level is sufficient to operate this generator. The oil capacity for this Model GEN154 2000 Surge Watts / 1500 Running Watts Portable Generator engine is 13.5 fluid oz. (0.40 L). To drain the oil from this generator: It is necessary to drain the oil from the crankcase only if it has become contaminated with water and/or dirt.
When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as shown in Figure 8. Oil Capacity (fluid oz./L) 13.5 / 0.40 Oil Type Recommended High Detergent Motor Oil, SAE10W-30

Figure 8 – Adding oil

Air Filter Maintenance Routine maintenance of the air filter helps maintain proper airflow to the carburetor. Occasionally verify that the air filter is free of excessive dirt. The air filter will require more frequent cleaning when operating this generator in extremely dusty areas.
To clean air filter, remove from generator. Wash in kerosene. Pour motor oil on filter, squeeze out excess oil and reinstall in the generator. Spark Plug Maintenance The spark plug is essential for proper engine operation. The spark plug should be intact, free of deposits, and properly gapped. A bad or incorrectly installed spark plug can cause engine damage. To inspect the spark plug:
recommended.

Figure 9 - Measuring the spark plug gap Emptying the Fuel Tank To store this generator for extended time, drain the gasoline from the fuel tank. To drain gasoline from this generator:
Do not store gasoline for more than 3 months.

Storage Time Recommended Storage Procedure (which will help prevent difficult starts) Less than 1 month No storage procedure required. 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.) 1 year or more Empty the fuel tank. (See “Emptying the Fuel Tank” in the “Maintenance/Care” section.) Disconnect the spark plug. TROUBLESHOOTING IMPORTANT: If trouble persists, call our customer help line at 1-888-287-6981, Monday - Friday, 8 AM - 4 PM Central Time.

Symptom Cause Solution Engine switch is set to "off." Set engine switch to "on." Fuel valve is turned to "closed." Turn fuel valve to "open." Choke is open. Close the choke. Engine is out of gasoline. Add gasoline. Engine is filled with contaminated and/or old gasoline.
Engine will not start.
Drain gasoline from the engine and add new gasoline. Spark plug is dirty. Clean spark plug. Spark plug is broken. Replace spark plug. Generator is not on level surface. Move generator to a level surface to prevent triggering the low oil shutdown.
Oil is low. Add or replace oil. Circuit breaker is off. Flip circuit breaker to "on." Reset button is "off." Push reset button to "on." Bad connecting wires/cables. Try a different extension cord.
Engine runs but there is no electrical output.
Bad electrical device connected to generator. Disconnect device, try connecting another device. Generator is overloaded. Reduce draw on generator to within this generator's rated wattage by reducing number of connected electrical devices. Short in one of the connected devices. Disconnect any faulty or short-circuited electrical loads.
Generator runs but does not support all connected electrical devices.
Air filter is dirty. Clean or replace air filter.






GEN154 2000 SURGE WATTS / 1500 RUNNING WATTS PORTABLE GENERATOR PARTS LIST No. Part Name Part Number Qty No. Part Name Part Number Qty

1 Bolt GB5789 M5*8 2 46 Washer GB95 8 2
2 Absorber Set GR1000 A-04.00 2 47 Nut GB/T6184 M8 2
3 Control Panel GR1000 A-05.00 1 48 Cover 1
5 Bolt GB5780 M6*90 4 50 Bolt GB/T6184 M8 4
6 Spring Washer GB93 6 4 51 Washer 2
7 Washer GB95 6 4 52 Washer GB95 8 2
8 Bolt GB16674 M6*12 1 53 Spring Washer GB93 8 2
9 Fixed Talon 1 54 Nut GB/T6170 M* 2
10 Rear Cover 1 55 Washer GB95 6 1
26 Engine Assembly GB/T6174 M8 1 27 Nut GB95 8 4 28 Washer GB95 8 1 29 Washer GB93 8 1 30 Spring Washer 1 31 Bolt GB5780 M8*20 2 32 Frame Assembly GR1000A-01.00 1 33 Rubber Cushion GR1000A-16 4 34 Washer GB95 8 8 35 Spring Washer GB93 8 8 36 Nut GB/T6170 M8 2 37 DC Plug 6 38 DC Socket 4 39 AC Socket 1 40 Pilot Lamp 3 41 Flat Washer 1 42 DC Protector 1 43 AC Protector 1 44 Screw GB/T818 M6*16 4 45 Bolt GB5781 M8*20 2

Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Engine will not start. | Engine switch is set to "off." | Set engine switch to "on." | p.21 |
| Engine will not start. | Fuel valve is turned to "closed." | Turn fuel valve to "open." | p.21 |
| Engine will not start. | Choke is open. | Close the choke. | p.21 |
| Engine will not start. | Engine is out of gasoline. | Add gasoline. | p.21 |
| Engine will not start. | Engine is filled with contaminated and/or old gasoline. | Drain gasoline from the engine and add new gasoline. | p.21 |
| Engine will not start. | Spark plug is dirty. | Clean spark plug. | p.21 |
| Engine will not start. | Spark plug is broken. | Replace spark plug. | p.21 |
| Engine will not start. | Generator is not on level surface. | Move generator to a level surface to prevent triggering the low oil shutdown. | p.21 |
| Engine will not start. | Oil is low. | Add or replace oil. | p.21 |
| Engine runs but there is no electrical output. | Circuit breaker is off. | Flip circuit breaker to "on." | p.21 |
| Engine runs but there is no electrical output. | Reset button is "off." | Push reset button to "on." | p.21 |
| Engine runs but there is no electrical output. | Bad connecting wires/cables. | Try a different extension cord. | p.21 |
| Engine runs but there is no electrical output. | Bad electrical device connected to generator. | Disconnect device, try connecting another device. | p.21 |
| Generator runs but does not support all connected electrical devices. | Generator is overloaded. | Reduce draw on generator to within this generator's rated wattage by reducing number of connected electrical devices. | p.21 |
| Generator runs but does not support all connected electrical devices. | Short in one of the connected devices. | Disconnect any faulty or short-circuited electrical loads. | p.21 |
| Generator runs but does not support all connected electrical devices. | Air filter is dirty. | Clean or replace air filter. | p.21 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.