User Manual





VΩ terminal 10A terminal











2. Set the range switch to desired AC or DC position. If the current magnitude to be measured is not known beforehand, set the ranges switch to the highest range position and then reduce it range by range until satisfactory resolution is obtained. 3. Open the circuit to be measured and connect test leads in SERIES with the load in with current is to measure. 4. Current reading will be displayed on LCD, for DC current measurement, the polarity of the red probe will also be indicated. Please note: When the display shows the over range symbol “1”, a higher range must be selected. In addition “10A” function is designed for intermittent use only. RESISTANCE MEASUREMENT 1. Connect red lead to “VΩ”, black lead to “COM”. 2. Set the range switch to desired Ω range. 3. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before measurement. 4. Connect test leads to circuit being measured. 5. Read resistance value on Digital Display. Please note:

CAPACITY MEASUREMENT 1. Connect the BLACK test lead to the COM jack and the RED to the mA jack. 2. Set the Range switch at F position. (NOTE: The polarity of the RED lead is positive “+”) 3. Connect test leads across the capacitor under measure and be sure the polarity of connection is observed. Please Note: To avoid damage to the Meter, disconnect circuit power and discharge all high-voltage capacitors before measuring capacitance. The tested capacitor should be discharged before the testing procedure. Never apply voltage to the input, or serious damage may result. CONTINUITY TEST 1. Connect the BLACK test lead to the “COM” jack and the RED to the “VΩ” jack (Note: The polarity of the red test lead is positive “+”). 2. Set the range switch to
range 3. Connect the test leads across the load to be measured. 4. If the circuit resistance is lower than about 30±20Ω, the built- in buzzer will sound. DIODE MEASUREMENT 1. Connect red lead to “VΩmA”, black lead to “COM”. 2. Set RANGE switch to “
” position. 3. Connect the red test lead to the anode of the diode to be measured and black test lead to cathode.

4. The meter will show the approximate forward voltage of the diode. If the connections are reversed, “1” will be shown on the display. TRANSISTOR hFE MEASUREMENT 1. Set the range switch to hFE range. 2. Connect the adapter to the “COM” jack and the “hFE” jack. Don’t reverse the connection. 3. Identify whether the transistor is NPN or PNP type and locate Emitter, Base and Collector lead. Insert the leads of the transistor to be tested into the proper holes of the transistor test socket of the adaptor. 4. LCD display will show the approximate hFE value. BATTERY AND FUSE REPLACEMENT 1) Battery and fuse replacement should only be done after the test leads have been disconnected and power is off. 2) Loosen screws with suitable screwdriver and remove case bottom. 3) The meter is powered by a single 9V PP3 battery. Snap the battery connector leads to the terminals of a new battery and reinsert the battery into the case top. Dress the battery leads so that they will not be pinched between the case bottom and case top. 4) The meter is protected by fuse: A) mA: F0.5A/600V Fast, Breaking capacity is 10KA, dimensions are 20 x 5mmØ. B) 10A: F10A/600V Fast, Breaking capacity is 10KA, dimensions are 20 x 5mmØ.

This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste
at the end of its useful life. The goods must be disposed
of according to your local council guidelines.
Errors and omissions excepted.
Copyright© 2021 AVSL Group Ltd, Unit 2 Bridgewater Park,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
AVSL (Europe) Ltd, Unit 3D North Point House,
North Point Bus. Park, New Mallow Road, Cork, Ireland.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.