EN
Official user manual

Getac Digitizer Module (GET125K)

8 pages·364 KB·Computer Equipment·PDF·ENDEFRITNLJA
Getac Digitizer Module (GET125K)
Table of Contents 1 sections Federal Communication Commission Interference Statement ShowHide
Page 1 of the Getac Digitizer Module (GET125K) user manual
Page 1 · click to enlarge
Page 1

GET-125 installation manual

A. The installation flow chart is as follows:

Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 1
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 2
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 3
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 4
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 5
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 6
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 7
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 8
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 9

6、Double-sided tape on the back of control card

Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 10

7 、 Double-sided adhesive is affixed to the back of antenna

Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 11
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 12
Getac Digitizer Module (GET125K) diagram (page 1)
Fig. 13

B. The detailed installation process is as follows:

1、 Attach shielding materia:

1.1. Use amorphous laminating machine, adjust the parameters

Show 8 more labels / short text on this page
1、Attach shielding materia · 2、Split control card · 3、Installation control card · 4、The performance test · 5、Clean the PCB · 8、Fixed control panel · 9、Paste insulating film · 10、Appearance test
Page 2 of the Getac Digitizer Module (GET125K) user manual
Page 2 · click to enlarge
Page 2

1.2. Joint before must ensure the neatness of PCB, shielding

materials, PCB, shielding materials and platform must

be perfectly, can't offset, shielding material can't

fold, not beyond the PCB edge, the intracrystalline

shrinkage is less than 1.0 mm. Figure 1 and 2:

Getac Digitizer Module (GET125K) diagram (page 2)
Fig. 14

Figure 1 Figure 2

2、 Split control card:

The control card is placed in the fixed slot, press the

work button, and separate the control card. As shown in

figure 3:

Getac Digitizer Module (GET125K) diagram (page 2)
Fig. 15

3、 Installation control card:

Insert the two gold finger ends of FPC at the connector

opening at the same time and insert the connector flatly.

before use; · figure 3

Page 3 of the Getac Digitizer Module (GET125K) user manual
Page 3 · click to enlarge
Page 3

Push the line to the bottom of the connector and press down

4、 The performance test:

Test the electromagnetic panel to be tested by connecting

the test equipment to the test equipment:

Observe whether there are bending, line breaking, cursor not

in position, shake and other fault defects.

5、 Clean the PCB:

Wipe the front and back of the antenna plate with a

dust-free cloth dipped in alcohol。

6、 Double-sided tape on the back of control card:

the connector cover,

Page 4 of the Getac Digitizer Module (GET125K) user manual
Page 4 · click to enlarge
Page 4

On the back of the control card, paste 30*20*T0.1mm

7、 Double-sided adhesive is affixed to the back of antenna plate:

The antenna plate is folded down and pasted with black

8、 Fixed control panel:

The FPC of the antenna plate is folded by using the folding

tooling, and the control card is fixed on the back of the

double-sided adhesive, · 3M double-sided adhesive, · antenna plate,

Page 5 of the Getac Digitizer Module (GET125K) user manual
Page 5 · click to enlarge
Page 5

9 、 Paste insulating film:

Attach the yellow insulating film to the front of the

control card to avoid the connector on the control

10、 Appearance test:

Inspect the appearance of the finished product, screen and

label the defective products with defects such as the edge

of PCB, the edge of the board and the dirty surface of the

board.

C. inspection and packing

Send the good products to the inspection, after the

inspection qualified, packaging into the warehouse.

Page 6 of the Getac Digitizer Module (GET125K) user manual — Federal Communication Commission Interference Statement
Page 6 · click to enlarge
Page 6

Federal Communication Commission Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. IMPORTANT NOTE: This NFC devices must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. Any other installation or use will violate FCC Part 15 regulations. Modifications not expressly approved by Getac could void your authority to operate the equipment. This module apply limit module approval, and just only install in end product (Brand:Getac / Model: K120G2). FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: The product comply with the FCC portable RF exposure limit set forth for an uncontrolled environment and

are safe for intended operation as described in this manual. The further RF exposure reduction can be

achieved if the product can be kept as far as possible from the user body or set the device to lower output

power if such function is available.

End Product Labeling: The final end product must be labeled in a visible area with the following: “Contains FCC ID: QYLGET125K”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.

Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.

Ask about the Getac Digitizer Module (GET125K)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Getac Digitizer Module (GET125K)

Be the first to ask — other owners or our team will answer.

Original document

Getac Digitizer Module (GET125K) manual PDF

8 pages·364 KB·Computer Equipment·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…