Table of Contents 44 sections 1、 Attach shielding materia : · 1.1. Use amorphous laminating machine, adjust the parameters · before use; · 1.2. Joint before must ensure the neatness of PCB, shielding · … ShowHide
1、 Attach shielding materia :p.11.1. Use amorphous laminating machine, adjust the parametersp.1before use;p.21.2. Joint before must ensure the neatness of PCB, shieldingp.2materials, PCB, shielding materials and platform mustp.2be perfectly, can't offset, shielding material can'tp.2fold, not beyond the PCB edge, the intracrystallinep.2shrinkage is less than 1.0 mm. Figure 1 and 2:p.2Figure 1 Figure 2p.22、 Split control card :p.2The control card is placed in the fixed slot, press thep.2work button, and separate the control card. As shown inp.2figure 3:p.2figure 3p.23、 Installation control card :p.2Insert the two gold finger ends of FPC at the connectorp.2Push the line to the bottom of the connector and press downp.3the connector cover,p.34、 The performance test :p.3Test the electromagnetic panel to be tested by connectingp.3the test equipment to the test equipment:p.3Observe whether there are bending, line breaking, cursor notp.35、 Clean the PCB :p.3Wipe the front and back of the antenna plate with ap.3dust-free cloth dipped in alcohol。p.36、 Double-sided tape on the back of control card :p.3On the back of the control card, paste 30*20*T0.1mmp.4double-sided adhesive,p.47、 Double-sided adhesive is affixed to the back of antenna plate :p.4The antenna plate is folded down and pasted with blackp.43M double-sided adhesive,p.48、 Fixed control panel :p.4The FPC of the antenna plate is folded by using the foldingp.4tooling, and the control card is fixed on the back of thep.4antenna plate,p.49 、 Paste insulating film :p.5Attach the yellow insulating film to the front of thep.5control card to avoid the connector on the controlp.510、 Appearance test :p.5Inspect the appearance of the finished product, screen andp.5label the defective products with defects such as the edgep.5C. inspection and packingp.5Send the good products to the inspection, after thep.5Industry Canada statement:p.8
Page 1 of the Getac Digitizer Module (GET-125) user manual — 1.1. Use amorphous laminating machine, adjust the parameters
Page 1 · click to enlarge
Page 1

GET-125 installation manual

A. The installation flow chart is as follows:

Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 1 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 2 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 3 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 4 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 5 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 6 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 7 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 8 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 9 · 1、 Attach shielding materia :

6、Double-sided tape on the back of control card

Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 10 · 1、 Attach shielding materia :

7 、 Double-sided adhesive is affixed to the back of antenna

Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 11 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 12 · 1、 Attach shielding materia :
Getac Digitizer Module (GET-125) — 1、 Attach shielding materia : diagram (page 1)
Fig. 13 · 1、 Attach shielding materia :

B. The detailed installation process is as follows:

1、 Attach shielding materia :

1.1. Use amorphous laminating machine, adjust the parameters

Show 8 more labels / short text on this page
1、Attach shielding materia · 2、Split control card · 3、Installation control card · 4、The performance test · 5、Clean the PCB · 8、Fixed control panel · 9、Paste insulating film · 10、Appearance test
Page 2 of the Getac Digitizer Module (GET-125) user manual — figure 3
Page 2 · click to enlarge
Page 2

before use;

1.2. Joint before must ensure the neatness of PCB, shielding

materials, PCB, shielding materials and platform must

be perfectly, can't offset, shielding material can't

fold, not beyond the PCB edge, the intracrystalline

shrinkage is less than 1.0 mm. Figure 1 and 2:

Getac Digitizer Module (GET-125) — before use; diagram (page 2)
Fig. 14 · before use;

Figure 1 Figure 2

2、 Split control card :

The control card is placed in the fixed slot, press the

work button, and separate the control card. As shown in

figure 3:

Getac Digitizer Module (GET-125) — Figure 1 Figure 2 diagram (page 2)
Fig. 15 · Figure 1 Figure 2

figure 3

3、 Installation control card :

Insert the two gold finger ends of FPC at the connector

opening at the same time and insert the connector flatly.

Page 3 of the Getac Digitizer Module (GET-125) user manual — 5、 Clean the PCB :
Page 3 · click to enlarge
Page 3

Push the line to the bottom of the connector and press down

the connector cover,

4、 The performance test :

Test the electromagnetic panel to be tested by connecting

the test equipment to the test equipment:

Observe whether there are bending, line breaking, cursor not

in position, shake and other fault defects.

5、 Clean the PCB :

Wipe the front and back of the antenna plate with a

dust-free cloth dipped in alcohol。

6、 Double-sided tape on the back of control card :

Page 4 of the Getac Digitizer Module (GET-125) user manual — On the back of the control card, paste 30*20*T0.1mm
Page 4 · click to enlarge
Page 4

On the back of the control card, paste 30*20*T0.1mm

double-sided adhesive,

7、 Double-sided adhesive is affixed to the back of antenna plate :

The antenna plate is folded down and pasted with black

3M double-sided adhesive,

8、 Fixed control panel :

The FPC of the antenna plate is folded by using the folding

tooling, and the control card is fixed on the back of the

antenna plate,

Page 5 of the Getac Digitizer Module (GET-125) user manual — Send the good products to the inspection, after the
Page 5 · click to enlarge
Page 5

9 、 Paste insulating film :

Attach the yellow insulating film to the front of the

control card to avoid the connector on the control

10、 Appearance test :

Inspect the appearance of the finished product, screen and

label the defective products with defects such as the edge

of PCB, the edge of the board and the dirty surface of the

board.

C. inspection and packing

Send the good products to the inspection, after the

inspection qualified, packaging into the warehouse.

Page 6 of the Getac Digitizer Module (GET-125) user manual — 9 、 Paste insulating film :
Page 6 · click to enlarge
Page 6

Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

- Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

This module has been tested for compliance to FCC Part 15

The module is tested for standalone mobile RF exposure use condition. Any other usage conditions such as co-location with other transmitter(s) or being used in a portable condition will need a separate reassessment through a class II permissive change application or new certification.

This transmitter is tested in a standalone mobile RF exposure condition and any co-located or simultaneous transmission with other transmitter(s) or portable use will require a separate class II permissive change re- evaluation or new certification. 2.4 Limited module procedures Please addressed (same as module request letter) 2.5 Trace antenna designs Not applicable. 2.7 Antennas The following antennas have been certified for use with this module; antennas of the same type with equal or lower gain may also be used with this module. The antenna must be installed such that 20 cm can be maintained between the antenna and users.

Antenna TypeLoop Antenna Antenna connectorN/A
Page 7 of the Getac Digitizer Module (GET-125) user manual — 9 、 Paste insulating film :
Page 7 · click to enlarge
Page 7

Radiation Exposure Statement: The product comply with the FCC portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body or set the device to lower output power if such function is available. This equipment complies with FCC mobile radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. If the module is installed in a portable host, a separate SAR evaluation is required to confirm compliance with relevant FCC portable RF exposure rules. IMPORTANT NOTE In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling: The final end product must be labeled in a visible area with the following: “Contains FCC ID:QYLGET125K”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.

Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.

OEM/Host manufacturer responsibilities OEM/Host manufacturers are ultimately responsible for the compliance of the Host and Module. The final product must be reassessed against all the essential requirements of the FCC rule such as FCC Part 15 Subpart B before it can be placed on the US market. This includes reassessing the transmitter module for compliance with the Radio and EMF essential requirements of the FCC rules. This module must not be incorporated into any other device or system without retesting for compliance as multi-radio and combined equipment This transmitter module is tested as a subsystem and its certification does not cover the FCC Part 15 Subpart B (unintentional radiator) rule requirement applicable to the final host. The final host will still need to be reassessed for compliance to this portion of rule requirements if applicable. As long as all conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed.

Page 8 of the Getac Digitizer Module (GET-125) user manual — Industry Canada statement:
Page 8 · click to enlarge
Page 8

Industry Canada statement:

This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable.

IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the Canada authorization is no longer considered valid and the IC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate Canada authorization. NOTE IMPORTANTE:

Dans le cas où ces conditions ne peuvent être satisfaites (par exemple pour certaines configurations

d'ordinateur portable ou de certaines co-localisation avec un autre émetteur), l'autorisation du Canada n'est plus

considéré comme valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances,

l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une autorisation

distincte au Canada.

The product can be kept as far as possible from the user body or set the device to lower output power if such

function is available. The final end product must be labeled in a visible area with the following: “Contains IC:

10301A-GET125K”.

Plaque signalétique du produit final

L'appareil peut être conservé aussi loin que possible du corps de l'utilisateur ou que le dispositif est réglé sur la puissance de sortie la plus faible si une telle fonction est disponible. Le produit final doit être étiqueté dans un endroit visible avec l'inscription suivante: "Contient des IC: 10301A-GET125K ". Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. Manuel d'information à l'utilisateur final L'intégrateur OEM doit être conscient de ne pas fournir des informations à l'utilisateur final quant à la façon d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final qui intègre ce module. Le manuel de l'utilisateur final doit inclure toutes les informations réglementaires requises et avertissements comme indiqué dans ce manuel.

End Product Labeling

Ask about the Getac Digitizer Module (GET-125)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Getac Digitizer Module (GET-125)

Be the first to ask — other owners or our team will answer.

Original document

Getac Digitizer Module (GET-125) manual PDF

9 pages·306 KB·Computer Equipment·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…