PCE-AM 45 Anemometer User Manual

русский, 中文) can be found by using our product search on: www.pce-instruments.com

2 Specifications ........................................................................................ 2
3 Delivery scope ....................................................................................... 2
4 Device description ................................................................................ 3
4.1 Display description ........................................................................................................... 5
4.2 Numeric keypad ............................................................................................................... 6
5 Switching the meter on and off ........................................................... 7
5.1 Automatic power off.......................................................................................................... 7
6 Making a measurement ........................................................................ 8
6.1 Beaufort scale .................................................................................................................. 9
6.2 Setting the flow unit .......................................................................................................... 9
6.3 Setting the temperature unit ............................................................................................. 9
7 Volume flow measurement .................................................................. 9
7.1 Setting the unit of the volume flow measurement ............................................................. 9
7.2 Area specification for volume flow measurement .............................................................10
7.3 2/3 MAX volume flow measurement ................................................................................10
8 Lowest, highest and average measured value ................................ 10
8.1 Highest measured value ..................................................................................................10
8.2 Average reading ..............................................................................................................11
8.3 Lowest measured value ..................................................................................................11
8.4 Wind direction .................................................................................................................11
8.5 Freezing the measured value ..........................................................................................12
8.6 Recording the measured values ......................................................................................12
9 Software ............................................................................................... 13
10 Warranty ............................................................................................... 16
11 Disposal ............................................................................................... 16
Contents

1 Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.

3 Delivery scope 1 x handheld anemometer PCE-AM 45 1 x micro USB cable 1 x carrying case 4 x 1.5 V AAA battery 1 x user manual



No. Description 1 Shift key between:
- MAX: highest measured value - AVG: average measured value - MIN: lowest measured value Numeric keypad digit: 1 2 Enter key (ENTER) 2/3 V Max key Wind direction calibration key Numeric keypad digit: 2 3 Freeze display (HOLD) Numeric keypad digit: 3 4 Select between wind speed and volume flow Numeric keypad digit: 4 5 Unit shift key (UNIT) (short press) Switching the key tone on and off (long press) Numeric keypad digit: 5 6 On/off switch (long press) Numeric keypad digit: 6 7 Setting the temperature unit (short press) Select between temperature and humidity display (long press) Numeric keypad digit: 7 8 Setting the area for volume flow measurement (AREA) Setting the storage interval (SAMPLE) Numeric keypad digit: 8 9 Opening the memory menu (read, save, record) Numeric keypad digit: 9 10 Save a measured value Opening the recording menu Numeric keypad digit: 0 11 Clear memory Numeric keypad digit: . 12 USB interface for data transfer 13 LC display 14 Connection for the flow sensor 15 Connection cable of the flow sensor 16 Handle of flow sensor 17 Telescopic arm of flow sensor 18 Flow sensor

4.1 Display description


No. Meaning 1 2/3 of the maximum display for volume flow measurement 2 Display of the highest measured value 3 Display of the average reading 4 Display of the lowest measured value 5 Display of the saved measured value 6 Measured value is saved 7 Clearing the memory 8 Data connection with a PC has been established 9 Battery voltage too low 10 Measured value frozen 11 Beaufort scale 12 Units for speed display 13 When displayed, the flow value is shown 14 Displayed measured value must be multiplied by 100 15 When displayed, the volume flow is shown 16 Measured value 17 Unit: CFM (FT³/min) 18 Unit: CMM (m³/min) 19 Display for temperature, area and memory 20 Unit 21 Angle display 22 Unit: relative humidity 23 Compass direction E: East W: West S: South N: North ES: Southeast EN: Northeast WS: Southwest WN: Northwest 24 Indication that there is no saved data
4.2 Numeric keypad
It may happen that a number has to be entered; for example, when entering the memory interval. To enter this function, each key changes its function to a specific numerical key. All four cells must always be completed for each entry. A comma key is also available for volume flow measurement.

5 Switching the meter on and off To switch the meter on and off, press and hold the on/off key for at least two seconds.
5.1 Automatic power off
If no entry is made within five minutes after switching on, the meter switches itself off. To deactivate this function, hold down the Enter key when switching on and switch on the meter. The display shows "no". The automatic power off function is now deactivated. Now release all keys to make a measurement. The automatic power off function reactivates whenever the meter is switched off.


To make a measurement, align the flow sensor with the flow direction. An arrow inside the sensor indicates the orientation in relation to the wind flow. Wait for at least two seconds for the reading to stabilise.

6.1 Beaufort scale
The Beaufort scale is always active and shows the current wind force category

6.2 Setting the flow unit
To set the unit of the flow velocity, press the "UNIT" key. You can choose between m/s, km/h, ft/min, knots and mps. The default setting is m/s.

6.3 Setting the temperature unit
To set the temperature unit displayed, press and release "°C/°F" once. You can choose between °C and °F. The default setting is °C.
7 Volume flow measurement For a volume flow measurement, first press the "VEL/FLOW" key to select between velocity and volume flow measurement. This is signalled by "VEL" (speed measurement) and "FLOW" (volume flow measurement) on the display. Depending on the entered area and the measured wind flow, the measured value can also be significantly higher than it is possible to display. In this case, "x100" or "x10" is displayed next to the measured value. The measured value in the display must then be multiplied by 100 or 10 accordingly.

7.1 Setting the unit of the volume flow measurement
To select the unit FT³ or m³, press and release the "UNIT" key once. Hint: The function also has an effect on the area specification.

7.2 Area specification for volume flow measurement
In order to perform a volume flow measurement, it is mandatory to perform an area measurement of the flow. To do this, press the "AREA/SAMPLE" key in volume flow mode. Now enter the area. The unit of measurement m2 or FT2 flashes next to the display. Set the corresponding unit of measurement before entering the area.

7.3 2/3 MAX volume flow measurement
During the volume flow measurement, it is possible to display 2/3 of the maximum volume flow. To do this, press the "ENTER" key. 2/3 MAX" appears on the display. Only 2/3 of the maximum measured value will be displayed. Press the "ENTER" key again to exit the mode.

8 Lowest, highest and average measured value For velocity and volume flow measurement, the lowest / highest and the average measured value can be displayed by pressing a key. To use these functions, repeatedly press the "MAX/MIN" key until you have reached your desired function.
8.1 Highest measured value
When displaying the highest measured value, only the highest measured value is displayed after activating this function. When "MAX" is displayed, this function is active. When the function is changed, the value expires.


8.2 Average reading
When the average reading is displayed, the average of the last 10 seconds is displayed. When "AVG" is displayed, this function is active. When the function is changed, the value expires.

8.3 Lowest measured value
When the lowest measured value is displayed, it is only the lowest measured value that is displayed. When "MIN" is displayed, this function is active. When the function is changed, the value expires.

8.4 Wind direction
For wind direction measurement, there is an additional gyroscope in the wind speed sensor. The wind direction can be determined via this sensor. To do this, hold the sensor vertically to the air flow. Pay attention to the marking inside the sensor for the flow direction. The display shows the current angle degree and the compass direction as letters: E: East W: West S: South N: North ES: Southeast EN: Northeast WS: Southwest WN: Northwest

8.4.1 Calibrating the wind direction
The wind direction should be calibrated when the meter is first put into operation, when it is located in a different region and at regular intervals. To do this, switch on the meter and then align the sensor vertically. Now press and hold the "ENTER" key until the wind direction indicator flashes "- - -". Now rotate the sensor vertically around its own axis twice for 8 seconds each. Then press the "Enter" key. The calibration is complete.

8.5 Freezing the measured value
To freeze and hold the currently displayed reading, press and release the "HOLD" key once. The reading is now held. HOLD" appears on the display. Press the "HOLD" key again to resume the measurement.

8.6 Recording the measured values
To record individual measured values, the storage interval must be set to "0000" seconds. The storage interval can only be set when the air velocity measuring function "VEL" is set. To do this, press the "SAMPLE" key and now set the storage interval accordingly. Then press the "REC" key whenever you want to save the current measured value. The memory location used is shown on the lower display and the "REC" display flashes once briefly above the display. For continuous recording, set a desired storage interval with the "SAMPLE" key. You can select between 1 ... 9999 seconds. Then press the "REC" key once. The lower display briefly shows the storage interval. REC" is shown above the display. This signals that the measured values are being recorded. To interrupt saving, keep the "REC" key pressed. If you press the "REC" key again, recording will be restarted. Date and time are only saved when recording with the software.
8.6.1 Read out data memory
To read out the data memory on the meter, press and release the "READ" key once. "READ" is now shown above the display. All readings displayed are now those from the memory. Each time you press the "READ" key, the next memory value is displayed. Now press the "AREA/SAMPLE" key and type in the memory location you want to read out. To return to normal measuring mode, keep the "READ" key pressed until "READ" disappears from the display.

8.6.2 Delete data
The meter has a memory with 960 measuring points. As soon as the memory is full, "FULL" is shown on the display. To delete the measurement data on the meter, press and hold the "DEL" key for at least two seconds until "CLA" is displayed and "DEL" lights up. All saved data have now been deleted. Hint: Only the entire memory can be cleared.

9 Software To install the software, first go to the page: https://www.pce-instruments.com/english/download-win_4.htm where you can download and install the latest software. Then connect the meter to the PC and open the software with administrator rights. As soon as the meter is connected to the PC, the automatic power off function is deactivated.

Button Function "Real Time Measure Live view of the measurement "Device Storage" Reading out the memory of the meter. The window for viewing the saved readings on the meter has an identical structure. "Erase Storage" Clearing the memory of the meter. As soon as you click on this button, all measured values are immediately deleted. There is no warning in advance.


Export a current live measurement. The data is saved as XLS.
Save an anemometer file File format .ane and .xls This function is only available when reading out the meter. Close window
The scaling of the current graph is adjusted so that all measured values in the current measurement period are visible in one window.

The exported data is saved in XLS format. This could look like this, for example:

After you have selected "Real Time Measure", a new window opens for live measurement on the PC. From here, the measurement data is transferred directly to the PC.


To set the read interval, click on "Option" and then select "Read interval(sec)". In the next window, you can set the interval in seconds.

Below the window, you can see whether a meter is connected. In addition, the current window can be printed. A print preview can be started before printing. There is also a status bar for the current status of importing a file.

10 Warranty You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms
11 Disposal For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.

PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com [email protected] [email protected] www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom, SO31 4RF Italia Türkiye Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk [email protected] info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish The Netherlands United States of America
PCE Brookhuis B.V. PCE Americas Inc. Institutenweg 15 1201 Jupiter Park Drive, Suite 8 7521 PH Enschede Jupiter / Palm Beach Nederland 33458 FL Telefoon: +31 (0)53 737 01 92 USA [email protected] Tel: +1 (561) 320-9162 www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us
Germany France Spain
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.