EN
Bogen logo
Official user manual

Bogen Microphone Input Module (MIC1X)

3 pages·97 KB·Home Audio·PDF·ENDEFRITNLJA
Bogen Microphone Input Module (MIC1X)
Table of Contents 37 sections MIC1X · THRESH G · E T A DUR · MIC 1 X · … ShowHide
Page 1 of the Bogen Microphone Input Module (MIC1X) user manual — MIC1X
Page 1 · click to enlarge
Page 1

MIC1X

THRESH G

E T A DUR

MIC 1 X

TREB LIMIT

GAIN

BASS

Microphone Input Module

MIC IN

G

Features

  • Transformer-balanced
  • Gain/Trim control
  • Bass and treble
  • Gating
  • Gating threshold and duration adjustments
  • Variable Threshold Limiter
  • Limiter Activity LED
  • 4 levels of available priority
  • Can be muted from higher priority modules
  • Can mute lower priority modules

© 2001 Bogen Communications, Inc. 54-2052-01C 0701 Specifications subject to change without notice.

Page 2 of the Bogen Microphone Input Module (MIC1X) user manual — MIC IN
Page 2 · click to enlarge
Page 2
Bogen Microphone Input Module (MIC1X) — Jumper Selections diagram (page 2)
Fig. 1 · Jumper Selections

Jumper Selections

1. Turn off all power to the unit.

PRIORITY LEVEL

This module can respond to 4 different levels of priority. Priority 1 is the highest priority. It mutes modules with lower priorities and is never muted. Priority 2 can be muted by Priority 1 modules and mutes modules set for 3 or 4. Priority 3 is muted by either Priority 1 or 2 modules and mutes Priority 4 modules. Priority 4 modules are muted by all higher priority modules.

2 3 4 (Lowest)

3. Position module in front of desired module bay opening, making sure that the module is rightside up.

J6 J7 J8 J6 J7 J8 J6 J7 J8 J6 J7 J8

4. Slide module on to card guide rails. Make sure that both the top and bottom guides are engaged.

GATING

BUS ASSIGNMENT

J6 J7 J8

* The number of priority levels available is determined by the amplifier the modules are used in.

J4

5. Push the module in to the bay until the faceplate contacts the unit’s chassis.

Both J5 J5 J5

A B

J4

J4

PHANTOM

6. Use the two screws included to secure the module to the unit.

Gating (turning off) of the modules output when insuffi- cient audio is present at the input can be disabled. Detection of audio for the purpose of muting lower prior- ity modules is always active regardless of jumper setting.

POWER

J5

J2

J2

24V phantom power can be supplied to condenser microphones when jumper is set to ON position. Leave OFF for dynamic mics.

J2

This module can be set to operate so that the MIC signal can be sent to the main unit’s A bus, B bus, or both buses.

Gate - Threshold (Thresh)

Gate - Duration (Dur)

Controls the minimum necessary input signal level to turn the module’s out- put on and apply signal to the main unit's buses. Clockwise rotation increas- es the necessary signal level required to produce output and mute lower priority modules.

Controls the amount of time the output and mute signal of the module remains applied to the main unit’s buses after the input signal falls below the required minimum signal level (set by the threshold control).

MIC1X

THRESH G

E T A DUR

TREB LIMIT

Bass & Treble (Treb)

Sets the signal level threshold at which the module will begin to limit the level of its output signal. Clockwise rotation will allow more output signal before limiting, counterclockwise rotation will allow less.The limiter moni- tors the module’s output signal level, so increasing Gain will affect when lim- iting takes place.An LED indicates when the Limiter is active.

GAIN

BASS

Provides separate controls for Bass and Treble cut and boost.The Bass control affects frequencies below 100 Hz and Treble affects frequencies above 8 kHz. Clockwise rotation provides boost, counterclockwise rotation provides cut. Center position provides no affect.

MIC IN

G

Uses standard female XLR to make connections to the module’s input. The input is low-impedance, transformer-balanced for excellent noise and ground loop immunity.

Provides control over the level of input signal that can be applied to the internal signal buses of the main unit. Allows a way to balance the input lev- els of various devices so that the main unit controls can be set to relative- ly uniform or optimum levels.

Show 14 more labels / short text on this page
Priority Level* · 1 (Highest) · Enabled · Bus · Disabled · Gating · Mono · On · Off · Phantom Power · Bus Assignment · Limiter (Limit) · Connections · Gain
Page 3 of the Bogen Microphone Input Module (MIC1X) user manual — BUS ASSIGNMENT
Page 3 · click to enlarge
Page 3

Block Diagram

BUS ASSIGNMENT

GAIN BASS/TREBLE GATING

LIMITER

BUS A

BUS B

INPUT

PHANTOM

ON / OFF

PRIORITY

LEVEL

GATE CONTROL

MUTE HIGH

MUTE MED

PHANTOM

MUTE LOW

POWER

GATE ENABLE/ DISABLE

MUTE OUT

MUTE IN

www.bogen.com

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Bogen Microphone Input Module (MIC1X)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bogen Microphone Input Module (MIC1X)

Be the first to ask — other owners or our team will answer.

Original document

Bogen Microphone Input Module (MIC1X) manual PDF

3 pages·97 KB·Home Audio·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…