Instruction/ maintenance manual of the product DCX 8510-4 Brocade Communications Systems
Go to page of 168
53-1002 1 7 7-0 5 1 0 May 20 12 ® 5 Brocade DCX 85 1 0-4 Backbone Hardware R ef erence Manual.
Copyright © 20 11-2012 Br ocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wi ng symbol, BigIron, DCX, Fabric OS, FastIron, MLX, NetIron, SAN Health, Ser verI.
Brocade DCX 8510-4 Backbone Hardware Reference Manual iii 53-1002177-05 Brocade DCX 85 1 0-4 Backbone Har dware Refe rence Manual 53-1002 1 7 7-02 Updated fill er panel graphics, CP replacement pr ocedures to 7 .0, data transmission range infor mation, and rack kit measurement.
iv Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05.
Brocade DCX 8510-4 Backbone Hardware Reference M anual v 53-1002177-05 Contents About This Document In this chapt er . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv How this document is organized . . . . . . . .
vi Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Preparing fo r Brocade DCX 85 1 0-4 installation . . . . . . . . . . . . . . . . 14 Unpacking and installing the Br ocade DCX 85 1 0-4 . . . . . . . . . . . . . 1 6 Items included with the Brocade DCX 85 1 0-4 .
Brocade DCX 8510-4 Backbone Hardware Reference M anual vii 53-1002177-05 Determining the status of a port, application, or encr yption blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Blade illustrations . . .
viii Brocade DCX 8510-4 Backbone Hardware R eference Manual 53-1002177-05 Po wer supply remov al and replacement . . . . . . . . . . . . . . . . . . . . . . 78 Time and items re quired . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Identifying pow er supplies .
Brocade DCX 8510-4 Backbone Hardware Reference M anual ix 53-1002177-05 Envir onmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 13 Fibre Channel port specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 1 14 Po wer specifications .
x Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05.
Brocade DCX 8510-4 Backbone Hardware Reference M anual xi 53-1002177-05 Figures Figure 1 Port side of the Brocade DCX 8 510-4 (sample configuration) . . . . . . . . . . . . . . . 4 Figure 2 Port side of the Brocade DCX 8510-4 with the port side exhaust kit installed (sample configuration) .
xii Brocade DCX 8510-4 Backbon e Hardware Reference Manual 53-1002177-05 Figure 33 QSFP cable connections for B rocade DCX 8510 chassis (sample configuration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Figure 34 DCX 8510 core/edge ICL topology .
Brocade DCX 8510-4 Backbone Hardware Reference M anual xiii 53-1002177-05 Tables Ta b l e 1 Blades available for the Broc ade DCX 8510-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Ta b l e 2 Installation tasks, time, and item s required .
xiv Brocade DCX 8510-4 Backbon e Hardware Reference Manual 53-1002177-05.
Brocade DCX 8510-4 Backbone Hardware Reference M anual xv 53-1002177-05 About This Document In this chapter • How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv • Suppor ted har dware and software.
xvi Brocade DCX 8510-4 Backbon e Hardware Reference Manual 53-1002177-05 Supported hardware and software • Appendix C, “Diagnostics and T roubleshooting,” pr ovides methods for receiving system-wide or component-lev el status and interpreting P OST and boot activities and diagnostic tests; it also includes troubleshoo ting tips.
Brocade DCX 8510-4 Backbone Hardware Reference M anual xvii 53-1002177-05 Document conventions Command syntax conventions Command syntax in this manu al follo ws these conventions: Command examples This book describes how to perform configuration tasks using the Fabric OS command line interface, but does not describe the commands in de tail.
xviii Brocade DCX 8510 -4 Backbone Hardware Reference Manual 53-1002177-05 Notice to the reader CAUTION A Caution stat ement aler ts y ou to situations that can be pot entially h azardous to you or cause damage to har dware, firmware, sof tware, or data.
Brocade DCX 8510-4 Backbone Hardware Reference M anual xix 53-1002177-05 Getting technical help For additional Br ocade documentat ion, visit the Brocade website: http://www .brocade.com Release no tes are a vailable on the MyBrocade webs it e and are also bundled with the Fabric OS firmw are.
xx Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Document feedback In addition, the chassisS how command displa ys the Brocade DCX 85 10-4 serial number , as well as inf ormation about the por t a nd application blades, an d other f ield-replaceabl e units (FRUs).
Brocade DCX 8510-4 Backbone Hardware Reference M anual 1 53-1002177-05 Chapter 1 Brocade DCX 8510-4 Backbone Overview In this chapter • Brocade DCX 85 10-4 f eatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Brocade DCX 85 10-4 har dware components .
2 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 hardware components 1 • Beginning with Fabric OS v7 .0. 1, up to nine chassis can be connect ed with the use of 4x1 6 Gbps quad SFP (QSFP) int er-chassi s links (ICLs).
Brocade DCX 8510-4 Backbone Hardware Reference M anual 3 53-1002177-05 Brocade DCX 8510- 4 hardware components 1 • Modular , hot-swappabl e encr yption blades: - FS8-18: 1 6-por t, up to 4 blades per chassi s, supporting in-flight data cr ypt ographic (encryption/decr yption) and data-compression capabilities.
4 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 hardware components 1 Port side of the Brocade DCX 8510-4 NOTE Air flow in the Br ocade DCX 85 10-4 is from the non por t side to the left side and por t side of the chassis (vie wed from the port side) and out the exhaust vents.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 5 53-1002177-05 Brocade DCX 8510- 4 hardware components 1 FIGURE 2 P or t side of the Brocade DCX 85 10-4 with the port side exhaust kit installe.
6 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 hardware components 1 Nonport side of the Brocade DCX 8510-4 Figure 3 displays a sample configuration of the non por t side view of the Brocade DCX 85 1 0-4.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 7 53-1002177-05 Brocade DCX 8510-4 blades 1 Brocade DCX 8510-4 blades Ta b l e 1 summarizes the por t, applicat ion, control proc essor , and core switch blades that are a vailable for the Brocade DCX 85 1 0-4.
8 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 High availability 1 High availability The following f eatures co ntribute to the Br oc ade DCX 85 1 0-4 hig h-availability design.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 9 53-1002177-05 Serviceability 1 Serviceability The Brocade DCX 85 10-4 pro vides the following f e atures to enhance and ensure serviceability: • Modular design with hot- swappable components. • Flash memor y that stores two firm wa re images per control pr ocessor .
10 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Security 1 Security The follo wing lis t highlights some of the ke y secu rity features available f or the Brocade DCX 85 10-4 and fo r other Brocade enter prise-class products ru nning Fabric OS 7 .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 11 53-1002177-05 Network managea bility 1 Network manageability The Bro cade DCX 85 10-4 has a single domain an d is managed as a single element with the Br ocade Network A dvisor .
12 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Network manageabili ty 1.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 13 53-1002177-05 Chapter 2 Installation of the Brocade DCX 8510-4 In this chapter • Time and items re quired . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 • Preparing f or Brocade DCX 85 1 0-4 installation .
14 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Preparing for Brocade DCX 85 10-4 installation 2 Preparing for Brocade DCX 8510-4 installation NOTE Read the saf ety notices before installation ( “Saf ety notices” ).
Brocade DCX 8510-4 Backbone Hardware Reference M anual 15 53-1002177-05 Preparing for Brocade DCX 8510-4 installation 2 The follo wing steps are required to ensure corre ct installation and operation. 1. Plan to install the Brocade DCX 85 10-4 with th e nonpor t side facing the air-intak e aisl e.
16 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Unpacking and installing the Brocade DCX 8510-4 2 Unpacking and installing the Brocade DCX 8510-4 Use the f ollowing proced ure to unpack and install y our Brocade DCX 85 1 0-4. CAUTION Use saf e lif ting practices when mo ving the product.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 17 53-1002177-05 Items included with the Brocade DCX 851 0-4 2 Items included with the Brocade DCX 8510-4 The Bro cade DCX 85 10-4 ships with the.
18 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Providing power to the Brocade DCX 8510-4 2 Providing power to the Brocade DCX 8510-4 Complet e the following st eps to pr ovide pow er to the chassis. DANGER Use the supplied power cor ds.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 19 53-1002177-05 Chassi s slots 2 • FC1 6-32 por t blade — Por ts are numbered from 0 thr ough 15 from right t o lef t on the lower set of por ts and 1 6 throug h 3 1 from right t o lef t on the upper set of por ts.
20 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Cable management 2 Cables can be org anized and manag ed in a variety of ways, f or example, using cable chan nels on the sides of the cabinet or patch panels to mini mize cable management.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 21 53-1002177-05 Cable manage ment 2 FIGURE 4 Cable design for t he mSFP patch cables for the FC8-64 high density port blade Note that the duplex clip on the mSFP end of th e cable is black for easier recognition.
22 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Cable management 2.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 23 53-1002177-05 Chapter 3 Logging In and Configuring the Brocade DCX 8510-4 In this chapter • Configuring the Br ocade DCX 85 10-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 • Establishing a seri al connection to the Brocade DCX 85 10-4 .
24 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Establishing a serial connection to the Brocade D CX 8510-4 3 The configuration information is mirrored to the standby CP blade, which allows the current configuration to remain available e ven if the active CP blade fails.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 25 53-1002177-05 Logging in to the serial conso le port 3 1. V erify that the Br ocade DCX 85 1 0-4 is powered on and that POS T is com plete b y ver ifying that all pow er LED indicators on the por t, control pr oc essor , and core switch blades displa y a steady green light.
26 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Configuring the IP addresses 3 1. Log in t o the Brocade DCX 85 10-4 as admin . The default passwo rd is passwor d . At the init ial login, you are prompted to enter new admin and us er passwords.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 27 53-1002177-05 Logging off the serial console port and disconnecting the serial cable 3 NOTE The addresses 1 0.0.0.0 thr ough 10.0.0.2 55 are reser ved and used int ernally by the Brocade DCX 85 10-4.
28 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Customizing a switch name 3 NOTE Connecting the CP blades t o a pr ivat e network/VLAN is recommended.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 29 53-1002177-05 Setting the domain ID 3 2. Enter chassisName by itself to sho w the name. switch:admin> chassisname DCX8510_chassis 3. Recor d the new name for ref erence. Setting the domain ID Each switch in the fabr ic must have a unique do main ID.
30 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Setting the d ate and time 3 • HH is the hour; valid v alues are 00 through 23.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 31 53-1002177-05 Verifying the PID mode 3 Synchronizing local time T o synchronize the local time of the principal or pr imary switch with that of an ext ernal NTP ser ver , follo w these steps. 1.
32 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining installed software licenses 3 Y ou can check the PID setting using the con figshow command as in the f ollowing example. Y ou can use the | grep -i pid qualifier to pinpoint the PID information.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 33 53-1002177-05 Installing transceivers a nd attaching cables 3 The ports are color-coded t o indicate which c an be used in the same port group f or trunking (trunking por t groups can be up t o eight por t s).
34 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Installing transceivers and attaching cables 3 4. V erify the Broc ade DCX 85 10-4 and connector and por t status using the switchShow -qsfp command. A sample of the command output is shown belo w.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 35 53-1002177-05 Managing cables 3 748 3 28 7 ------ id 16G Online FC E-Port 10:00:00:05:1e:39:e4:5a trunkmaster name (Trunk master) 749 3 29 7 -.
36 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Verifying correct operation and backing up the conf iguration 3 Verifying correct operation and backing up the configuration T o verify correct operation and back up the Broca de DCX 85 10-4 configuration, f ollow these st eps.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 37 53-1002177-05 Powering off the Brocade DCX 8510- 4 3 Are you sure you want to shutdown the switch [y/n]?y HA is disabled Stopping blade 1 Shutting down the blade.... Stopping blade 2 Shutting down the blade.
38 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Powering off the Brocade DCX 8510-4 3.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 39 53-1002177-05 Chapter 4 Monitoring System Components In this chapter • Monitoring overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 • Determining the status of a port, applicat ion, or en cr yption b lade .
40 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Monitoring overview 4 0 1 0 820000 id N8 Online FC F-Port 10:00:00:05:1e:f8:a0:b4 1 1 1 820100 id N8 Online FC F-Port 10:00:00:0.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 41 53-1002177-05 Monitoring overview 4 36 1 36 822400 id N8 No_Light FC 37 1 37 822500 id N8 No_Light FC 38 1 38 822600 id N8 No_Light FC 39 1 39.
42 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Monitoring overview 4 Factory Part Num: 60-1000376-08 Factory Serial Num: AHJ0420F086 Manufacture: Day: 21 Month: 5 Year: 2010 U.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 43 53-1002177-05 Monitoring overview 4 POWER SUPPLY Unit: 2 Header Version: 2 Power Consume Factor: 2000 Factory Part Num: 23-0000067-01 Factory .
44 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a port, application, or en cryption blade 4 Determining the status of a port, application, or encryption blade Use the f ollowing proced ure to det ermine th e status of a por t or application blade.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 45 53-1002177-05 Determining the status of a port, application, or encryption blade 4 NOTE The FC8-64 port blade requires mSFPs (standar d SFPs do not fit) as w ell as narrow er OM-3 LC cables offered by major manuf acturers su ch as Corning, Mole x, and Amphenol.
46 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a port, application, or en cryption blade 4 FIGURE 9 FC1 6-32 por t blade FIGURE 1 0 FC16-48 port blad.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 47 53-1002177-05 Determining the status of a port, application, or encryption blade 4 FIGURE 1 1 FS8-18 encr ypt ion blade FIGURE 12 FX8-24 extension blade See “FX8-2 4 blade” fo r information about trunking g roups on this blade.
48 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a port, application, or en cryption blade 4 Ta b l e 3 describes the por t and application blade LE D patterns and the recommended actions f or those patterns.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 49 53-1002177-05 Determining the status of a port, application, or encryption blade 4 FC Por t Status No light (LE D is of f) Por t has no incoming power , o r there is no light or si gnal carrier detect ed.
50 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a control processor blade (CP8) 4 Determining the status of a control processor blade (CP8) Complet e the following st eps to det ermine the status of a control blade (CP8) 1.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 51 53-1002177-05 Determining the status of a core switch blade (CR16-4) 4 Determining the status of a core switch blade (CR16-4) Complet e the following st eps to det ermine the status of a core switch blade (CR1 6-4).
52 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a core switch blade (CR16-4) 4 FIGURE 1 4 Core switch blade (CR16-4) Ta b l e 5 describes the core switch blade LED patt erns and the recommended actions for those patterns.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 53 53-1002177-05 Determining the status of a power supply 4 Refe r to Figure 36 and Ta b l e 2 7 for a map of the ports and a table of external p.
54 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a blower assembly 4 FIGURE 1 5 Powe r su p pl y Ta b l e 6 describes the pow er supply LED patterns an d the recommended actions for those patterns.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 55 53-1002177-05 Determining the status of a WWN card 4 FIGURE 1 6 Blo wer assembly Ta b l e 7 describes the LED patterns f or the blow er assembly . Determining the status of a WWN card Complet e the following st eps to det ermine the status of a WWN card.
56 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a WWN card 4 NOTE The WWN bezel (logo plat e) covers the WWN car d s. The LEDs on the WWN car ds are not visible unless the bezel is remov ed. Enter the chassisShow command to displa y information about the WWN card.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 57 53-1002177-05 Determining the status of a WWN card 4 FIGURE 1 7 WWN bezel (logo plate) f or DCX 851 0-4.
58 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Determining the status of a WWN card 4.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 59 53-1002177-05 Chapter 5 Removal and Replacement Procedures In this chapter • Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
60 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Chassis door removal and replacement 5 Chassis door removal and replacement NOTE The chassis door must be installed to ensure the Br ocade DCX 85 10-4 mee ts EMI and other r eg ul at ory ce rti fi ca t io n s.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 61 53-1002177-05 Vertical cable manag ement fingers removal and replacement 5 Vertical cable management fing ers removal and replacement The Bro cade DCX 85 10-4 comes equipped with two vertical cable mana gement finger assemblies.
62 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Port, application, an d encryption blade removal and replacement 5 FIGURE 1 9 Remo val and replacement of the vertical cable man.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 63 53-1002177-05 Port, application, and encryption blade removal and replacement 5 Removing a blade For this pr ocedure, refer t o Figure 20 . Complet e the following st eps to remov e a blade. ATTENTION If multiple blades are being repl aced, replace one blade at a time.
64 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Port, application, an d encryption blade removal and replacement 5 11 . Perform the appropriat e following actio n based on the .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 65 53-1002177-05 Blade filler panel removal and replacement 5 • For FC8-64, FC8-32E, F C8-48E, FC16-32, FC16- 48 po r t blades, FX8-2 4 applica.
66 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Control processor blade (CP8 ) removal and replacement 5 FIGURE 2 1 R emoval and replacement of the blade filler panel Replacing a filler panel Do not lea ve a slo t empty . This will ad versely af fect cooli ng of the chassis.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 67 53-1002177-05 Control processor blade (CP8) remova l and replacement 5 ATTENTION Brocade’s firm ware upgrade policy f or CP8 blades specifies testing for the current F abric OS release and one version earlier .
68 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Control processor blade (CP8 ) removal and replacement 5 • The CP blade does not respond to T e lnet comm ands, or the serial console is not a vailable. • The slot Sh ow command does not sho w that the CP blade is enabled.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 69 53-1002177-05 Control processor blade (CP8) remova l and replacement 5 6. If both CP blade s are healthy and yo u want to replace the active CP blade, log in t o the active CP blade and run the f o llowing st eps: a.
70 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Control processor blade (CP8 ) removal and replacement 5 3. If the faulty CP is the active CP , issue the haFailov er command. Wait until the failov er has complet ed. Use the haShow command t o verify the CPs are sync hronized and the failo ver is complete.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 71 53-1002177-05 Control processor blade (CP8) remova l and replacement 5 bring both blades to the same f irmw are versio n.
72 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Control processor blade (CP8 ) removal and replacement 5 v7.0.0 5 CP1 FOS v6.3.0a STANDBY * v6.3.0a * Local CP WARNING: The local CP and remote CP have different versions of firmware, please retry firmwaredownload command.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 73 53-1002177-05 Control processor blade (CP8) remova l and replacement 5 DCX_124:admin> reboot Broadcast message from root (ttyS0) Fri Jun 18 14:49:45 2010.
74 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Control processor blade (CP8 ) removal and replacement 5 • firmw are • firmw areKey • suppor t The firmw are folder contains the f o lder f o r the specific release you are installing.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 75 53-1002177-05 Control processor blade (CP8) remova l and replacement 5 2010/06/18-14:56:50, [SULB-1002], 910, SLOT 7 | CHASSIS, INFO, Brocade_DCX, Firmwaredownload command has completed successfully.
76 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Core switch blade (CR16-4) removal and replacement 5 4. Pack the f aulty CP blade in the packaging pr ovided with the ne w CP blade, and contact the switch supplier to det ermine the return procedure.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 77 53-1002177-05 Core switch blade (CR16-4) removal and replacement 5 For more informatio n about err or messages, refer to the Fa b r i c O S M e s s a g e Re f e r e n c e .
78 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Power supply removal and replacement 5 FIGURE 23 Remov al and replacement of the core switc h blade (CR16-4) Replacing a core switch blade (CR16-4) Complet e the following st eps to replace the core switch blade .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 79 53-1002177-05 Power supply remova l and replacement 5 Time and items required The replacement pr ocedure for each po wer supply tak es less than five minutes. A powe r su pply unit or filler panel is required f or the power supply replacement.
80 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Blower assembly removal and replacement 5 FIGURE 25 Remov al and replacement of the power supply Replacing a power supply T o replace a power supply , complete the f ollowing steps.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 81 53-1002177-05 Blower assembly remo val and replacement 5 ATTENTION The Bro cade DCX 85 10-4 can continue operating during the replacement if t.
82 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 WWN card removal and replacement 5 FIGURE 26 Remov al and replacement of the blower assembly ‘ Replacing a blower assembly Complete the f ollowing steps t o replace the blower assembly in a chassis.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 83 53-1002177-05 WWN card removal and replacement 5 Time and items required Allow appr oximately 20 minut es to replace a WWN card.
84 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 WWN card removal and replacement 5 ATTENTION Follo w ESD precau tions (see “ESD Precautions” i n your chassis manual). 1. Open a T elnet session to the chassis and log in t o the active CP as admin.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 85 53-1002177-05 Transceiver remova l and replacement 5 Replacing the WWN card and WWN bezel (logo plate) For the following pr ocedure, please ref er to Figure 2 7 . Complet e the following st eps to replace the bezel and WWN car d.
86 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Transceiver removal and replacement 5 FIGURE 28 Optical transceiver (SFP+) extraction tool Removing an SFP+ transceiver For this pr ocedure, please refer t o Figure 29 . Complet e the following st eps to remov e an SFP+ transceiver .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 87 53-1002177-05 Transceiver remova l and replacement 5 FIGURE 29 Optical transceiver with bail open Replacing an SFP+ transceiver Complet e the following st eps to replace an SFP+ transc eiver . 1.
88 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Inter-chass is link (QSFP) ca ble removal and replacement 5 CAUTION The pull tabs are not designed to be be nt. Doin g so may result in damage t o the pull tab. Removing an mSFP transceiver For this pr ocedure, refer t o Figure 30 .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 89 53-1002177-05 Inter-chassis link (QSFP) ca ble removal and replacement 5 NOTE T h e Q S F P p o r t s c a n b e u s e d o n l y w i t h a n i n t e r - c h a s s i s link (ICL) license.
90 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Inter-chass is link (QSFP) ca ble removal and replacement 5 FIGURE 3 1 QSFP cable and transceiver Time and items required The replacement procedure f or an QSFP cable tak es less than fiv e minut es.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 91 53-1002177-05 Inter-chassis link (QSFP) ca ble removal and replacement 5 1. If the QSFP transceiv er is being replaced, grasp the bail of the ne w QSFP and push the QSFP into the co nnector on the blade until it is firm ly seat ed.
92 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Inter-chass is link (QSFP) ca ble removal and replacement 5 FIGURE 33 QSFP cable connections for Brocade DCX 8510 chassis (sa mp.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 93 53-1002177-05 Inter-chassis link (QSFP) ca ble removal and replacement 5 85 10 chassis can be connected in a core/edge configuration. Figure 34 shows two core and four edge chassis. Although 85 1 0-8 chassis are shown in the figure, the chassis can be either 85 10-4 or 85 1 0-8 .
94 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 85 10 chassis can also be connected in a full mesh conf iguration as shown in Figure 35 . Although 85 10-8 chassis are shown in the figure, the cha ssis can be either 85 10-4 or 85 1 0-8.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 95 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 4. Remo ving components fr om the chassis 5. Installing the replacement chassis 6. Installing components int o the new chassis 7.
96 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 • Intermitt ent F AUL T Y codes f or blades. R e-seat the blade and visually inspect the right-hand ejector stiffening rail for possible we ar or damage.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 97 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 1. Open a T elnet session and log in to the Brocade DCX 85 1 0-4 as admin . The def ault password is passwor d . E nable the logging fu nction on your T elnet or serial console connection.
98 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 5. Display and recor d the manufacturer serial numbers. Enter chassisShow ; then c opy the command output in to the config-miscinfo.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 99 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 switchName: switch <output truncated> switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name <output truncated> switch:admin> 7.
100 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 The system is going down for system halt NOW !! DANGER T urn of f the pow er switches and disconnect the power cor ds (D006) 2.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 101 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 CAUTION Use saf e lif ting practices when mo ving the product. (C01 5) ATTENTION A complet ely empty Brocade DCX 85 1 0-4 chassis weighs appr oximately 25.
102 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 5. Replace the core switch blades (CR16-4) ( “Core switch blade (C R1 6-4) removal and replacement” ).
Brocade DCX 8510-4 Backbone Hardware Reference M anual 103 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 4. Reboot the Brocade DCX 85 10-4. Verifying correct operation of the system Complet e the following st eps to v erify the correct operation of the Brocade D CX 85 1 0-4.
104 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 1 1 1 820100 id N8 Online FC F-Port 10:00:00:05:33:26:0e:65 2 1 2 820200 id N8 Online FC F-Port 10:00:00:05:33:48:5e:f5 3 1 3 820300 id N8 Online FC F-Port 10:00:00:05:1e:f8:a0:b3 (output truncated) 4.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 105 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 NOTE The por ts and cables used in trunking groups mu st meet specific req uirements. For a list of these requirements, ref er to the F abric OS Adminis trator’s Guide.
106 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 FID 1 | 1 | 1 | 1 | 1 | 128 | 128 | 128 | 128 | 128 | <output truncated> switch:admin> 2. Det ermine any differences between the informatio n in the SANafter .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 107 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39.
108 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Brocade DCX 8510-4 chassis removal and replacement 5 50 51 52 53 54 55 56 57 58 59 60 61 62 63 TA B L E 12 Cable routing table .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 109 53-1002177-05 Appendix A Specifications In this appendix • General specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 09 • System ar chitecture.
110 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 System architecture A System architecture Ta b l e 1 4 describes the syst em archit ecture of the Br ocade DCX 85 10- 4. Port to port latency Local switching - 800ns (add 400ns for E_Port to E_Po r t ); Blade to blade - 2.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 111 53-1002177-05 System size and weight A System size and weight The weight of the Brocade DCX 85 10-4 can vary considerably depending on the c ombination of blades installed.
112 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 System blade and FRU weights A System blade and FRU weights Ta b l e 1 6 lists the wei ghts of the co mpatible blades and FRUs. TA B L E 15 System size and w eight System Size or weight Width 43.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 113 53-1002177-05 Facility requirements A Facility requirements The facility whe re the Brocade DCX 85 10-4 is in use must meet the following req.
114 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Fibre Channel port specifications A NOTE The 0 ° to 40 ° Celsius range applies to the ambient air t e mperature at the air intake vents on the nonport side of the Brocade DCX 85 1 0-4.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 115 53-1002177-05 Power specifications A NOTE If an y of the follo wing intelligent blades are used, 200- 24 0 VA C is required: FS8-18, FX8-2 4. Ta b l e 1 8 sho ws the basic power specifications f or each power supply .
116 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Power cords A Pow er supply redun dancy is ke y to your installa tion, so any demand must be met with twice the capacity . See Ta b l e 2 0 for po wer supply requirements f or specific demand ranges.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 117 53-1002177-05 Power cords A TA B L E 21 Power cor d types (international) Country Plug style NEMA 5-20P 125V only USA, Canada, Mexico, other .
118 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Power cords A Malaysia Alternat e Recommended X Mexico X X X Monaco X X Netherlands X X New Zealan d XX Norway XX Pola nd X X P.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 119 53-1002177-05 Data transmission ranges A Power cord notice CAUTION This switch might ha ve more than one power co r d. T o reduce the risk of electric shock, disconnect all power cor ds bef ore ser vicing.
120 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Qualified cables for th e FC8-64 port blade A Qualified cables for the FC8-64 port blade Ta b l e 2 3 lists the thir d par ty cables that have been qu alified f or use with the mSFP transceivers in the FC8-64 high density port blade.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 121 53-1002177-05 Safety notices A Safety notices When using this product, observe the danger , caut ion, and attention notices in this manual. The notices are accompanied b y symbols that repres ent the sev erity of the safety condition.
122 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Regulatory compliance A • “BSMI statement (T aiwan)” on page 122 • “CE statement” on page 123 • “Canadian requi.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 123 53-1002177-05 Regulatory compliance A War n i n g : This is Class A product. I n a domestic envir onmen t, this product ma y cause radio inter ference, in which case the user ma y be required to tak e adequate measures.
124 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Environmental regulation compliance A Environmental regulation compliance This section describes the China R oHS env ironmen tal regulat or y compliance requirements f or the Brocade DCX 85 1 0- 4.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 125 53-1002177-05 Environmental regulatio n compliance A Environmental Protection Us e Period (EPUP) Disclaimer In no ev ent do the EPUP logos sh.
126 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Environmental regulation compliance A China RoHS hazardous substances/toxic substances (HS/TS) concentration chart In acco rdance with China's Managem ent Measures on t he Control of Polluti on caused b y Electro nic Information products (Decree No.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 127 53-1002177-05 Environmental regulatio n compliance A.
128 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Environmental regulation compliance A.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 129 53-1002177-05 Appendix B Application and Encryption Blades In this appendix • Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
130 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 FX8-24 blade B FX8-24 blade The FX8-2 4 blade has 12 ext ernal Fibre Channe l (FC) SFP por ts suppor ting the Fibre Channel Routing Services and 10 external 1 Gigabit Ethe rnet (GbE or GE) SFP po r ts suppor ting the Fibre Channel Over IP (FCIP) f eature.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 131 53-1002177-05 FX8-24 bl ade B • Vir tual E_por ts. • FCIP QoS. • Suppor t for 200 ms RTT (on a limit ed number of GbE por ts). • Adaptiv e Rate Limi ting (licensable) . • T CP per formance graphing in Web T ools.
132 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 FX8-24 blade B.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 133 53-1002177-05 Appendix C Diagnostics and Troubleshooting In this appendix • Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 • Obtaining chassis and compone nt status .
134 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Obtaining chassis a nd component status C Obtaining chassis and component status The CLI commands in Ta b l e 2 5 provide status and enviro nmenta l information about the chassis and its components.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 135 53-1002177-05 Diagnostics C • Re view the system err or log using the errShow or errDum p commands. Any err ors detect ed during POST are written to the syst em log, which is accessible thr ough the errShow command.
136 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Troubleshooting C All diagnostic t ests are run at al l suppor ted link speeds. The y might temporarily lock the transmit and receive spe eds to a specific speed. Some diag nostic tests require interconnecting the ports to each other or using loo pback plugs.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 137 53-1002177-05 Troubleshooting C Initial set up resul ts in IP address/Domain ID confli ct. The Brocade DCX 85 10-4 w as connected to the fabric befo re being configured. See the F abric OS Administrat or’s Guide fo r configu ration informat ion.
138 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Troubleshooting C One or more por t blad es have either shut down or failed POST as indicated b y the error log. Blades might be overheat ed. Enter the senso rShow command to check the internal temperature readings.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 139 53-1002177-05 Appendix D Port Numbering Template Print or copy the followi ng templat es in this appendix and use them t o document the por t numbering pattern f or the Brocad e DCX 85 10-4.
140 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Port Numbering Template D . FIGURE 3 7 FC8-64 port blade . FIGURE 38 FC8-32E port blade .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 141 53-1002177-05 Port Numbering Template D . FIGURE 40 FC1 6-32 por t blade . FIGURE 4 1 FC16- 48 por t blade .
142 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 Port Numbering Template D FIGURE 43 FX8-2 4 extension blade 1 1 0 GbE por ts 0-1 5 FC por ts 0-5 21 G b E p o r t s 0 - 3 6B l .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 143 53-1002177-05 Index Numerics 10 GbE ports , 130 A airflow, requirement , 114 altitude, requirement , 113 ambient temperature, requirement , 1.
144 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 command chassisName , 28 configShow , 36 configUpload , 36 configUpload -vf , 36 configure , 29 , 31 date , 29 fabricShow , 29 .
Brocade DCX 8510-4 Backbone Hardware Reference M anual 145 53-1002177-05 Fibre Channel port specifications , 114 Fibre Channel Association , xix Fibre Channel Routing Services , 130 field replaceable .
146 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05 latency port to port , 110 switch , 110 LEDs blower assembly , 55 CP blade , 50 CR blade , 52 port blade , 48 power supply , 54.
Brocade DCX 8510-4 Backbone Hardware Reference M anual 147 53-1002177-05 safety notices , 121 security , 10 serial connection establishing , 24 troubleshooting , 136 serial port logout , 27 serviceabi.
148 Brocade DCX 8510-4 Backbone Hard ware Reference Manual 53-1002177-05.
An important point after buying a device Brocade Communications Systems DCX 8510-4 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Brocade Communications Systems DCX 8510-4 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Brocade Communications Systems DCX 8510-4 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Brocade Communications Systems DCX 8510-4 you will learn all the available features of the product, as well as information on its operation. The information that you get Brocade Communications Systems DCX 8510-4 will certainly help you make a decision on the purchase.
If you already are a holder of Brocade Communications Systems DCX 8510-4, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Brocade Communications Systems DCX 8510-4.
However, one of the most important roles played by the user manual is to help in solving problems with Brocade Communications Systems DCX 8510-4. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Brocade Communications Systems DCX 8510-4 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center