EN
NextLight logo
Official user manual

NextLight PRO Series CONTROL

8 pages·756 KB·Controller·PDF·ENDEFRITNLJA
NextLight PRO Series CONTROL
Table of Contents 43 sections USER MANUAL · 2. Package Contents 3. Connections · A B · DC INPUT TEMP · … ShowHide
Page 1 of the NextLight PRO Series CONTROL user manual — USER MANUAL
Page 1 · click to enlarge
Page 1
NextLight PRO Series CONTROL — USER MANUAL diagram (page 1)
Fig. 1
NextLight PRO Series CONTROL — USER MANUAL diagram (page 1)
Fig. 2
NextLight PRO Series CONTROL — USER MANUAL diagram (page 1)
Fig. 3
NextLight PRO Series CONTROL — USER MANUAL diagram (page 1)
Fig. 4
NextLight PRO Series CONTROL — USER MANUAL diagram (page 1)
Fig. 5

USER MANUAL

Page 2 of the NextLight PRO Series CONTROL user manual — USER MANUAL
Page 2 · click to enlarge
Page 2
Page 2 of the NextLight PRO Series CONTROL user manual — USER MANUAL
Page 3 of the NextLight PRO Series CONTROL user manual — 4. Product Installation
Page 3 · click to enlarge
Page 3

2. Package Contents 3. Connections

NextLight Control Pro x1 12V AC/DC Adapter x1 Temperature Sensor x1 NextLight Pro Series Control Cable (20') x2

1 1 2 2 2

DC Input Temperature Sensor Input

Channel A Channel B

A B

DC INPUT TEMP

1 1 2 3 4

*Dust caps removed to show ports

4. Product Installation

  • The NextLight Control Pro can be mounted to the wall using two nails/screws and
  • Insert other end of Control Cable into Dim In connection on Driver of first Fixture in

mounting holes (3 3/8” apart) on back of controller.

lighting system chain.

  • Insert 12V AC/DC Adapter into DC Input and plug into a power source.
  • Connect Control Cable from Dim Out on Driver of first Fixture to Dim In on Driver
  • Screen will automatically turn on and you can continue setting up your controller.

of next Fixture in the lighting system chain.

  • Insert NextLight Pro Series Control Cable into Channel A/B of your NextLight
  • Repeat until all Drivers/Fixtures are connected.

Control Pro. Then screw the locking ring clockwise to ensure proper connection.

  • To ensure proper dimming control, make sure Onboard Dimmer on Driver is set to

EXT (External Control). Not applicable to all NextLight Pro Series fixtures.

NextLight PRO Series CONTROL — 4. Product Installation diagram (page 3)
Fig. 6 · 4. Product Installation
TEMP80.0°F A: 50% 08:00-20:00 OFF B: 50% 08:00-20:00 OFF 01/01/2021 07:00:00
Page 4 of the NextLight PRO Series CONTROL user manual — 7. Controls
Page 4 · click to enlarge
Page 4

5. Temperature Sensor

6. Main Screen

Temperature

Date/Time

Ambient temperature detected by

Current date and time of controller.

  • Insert Temperature Sensor into Temperature Sensor Input.

Temperature Sensor.

01/01/2021 07:00:00

  • Suspend the sensor down toward the space above the plant canopy, preferably not

TEMP: 80.0ºF

against the wall. Do not position the sensor in direct air flow.

  • Cover the sensor from direct light exposure from fixtures. Direct light cast upon

Outputs

sensor will affect the temperature readings and may cause premature auto

dimming (D. Auto-Save Temp) or shutdown (E. Shutdown Temp) of lighting system.

A

08:00-20:00

OFF

B

08:00-20:00

OFF

NextLight PRO Series CONTROL — OFF diagram (page 4)
Fig. 7

7. Controls

  • Press to view Settings Menu
  • Move selection up
TEMP80.0°F A: 50% 08:00-20:00 OFF B: 50% 08:00-20:00 OFF 01/01/2021 07:00:00
  • Press to save changes
  • Increase value
  • Shortcut to Output Power menu
  • Move selection down
  • Decrease value
  • Navigate back to previous menu
Show 13 more labels / short text on this page
*Example values shown · Channel · Dim % · Schedule · Current Status · 50% · 50% · Enter · Up · Brightness · Down · Back · *Main Screen Example
Page 5 of the NextLight PRO Series CONTROL user manual — OUTPUT SELECT CH-A: AUTO CH-B: AUTO
Page 5 · click to enlarge
Page 5

8. Settings

*Example values shown for all screen Settings

Settings Menu

B. Output Power

D. Auto-Save Temp

Press Enter to view Settings Menu

OUTPUT SELECT AUTO OUTPUT POWER CH-A: 50% CH-B: 50%

OUTPUT SELECT AUTO AUTO-SAVE TEMP 90.0°F

Output Select A.

Output Power B.

Light Timer C.

Auto-Save Temp D.

Set Output Power % for Channels A & B

Set temperature threshold for auto dimming to

Shutdown Temp E.

  • Press Up/Down to change value

50% of current setting

Rise/Fall F.

  • Press Enter to save changes
  • Press Up/Down to change Auto-Save Temp value

System Date/Time G.

  • Press Enter to save changes

Temp Calibrate H.

Factory Reset I.

For example:

Screen Saver J.

Current Output Power setting is 50%, it will auto dim

to 25% when temperature reaches 90ºF.

A. Output Select

C. Light Timer

E. Shutdown Temp

OUTPUT SELECT CH-A: AUTO CH-B: AUTO

OUTPUT SELECT AUTO CH-A:

ON: 08 : 00 OFF: 20 : 00

OUTPUT SELECT AUTO SHUTDOWN TEMP 100.0°F

CH-B:

ON: 08 : 00 OFF: 20 : 00

Set Output mode.

Set Light Timer ON/OFF values for hour/minute

Set temperature threshold to shut down fixture

  • Press Up/Down to change value
  • Press Enter to select channel
  • Set AUTO to use fixtures with controller
  • Press Up/Down to change hour
  • Press Up/Down to change Shutdown Temp value
  • Set ON to turn all fixtures ON at set
  • Press Enter to save hour change
  • Press Enter to save changes
  • Press Up/Down to change minute
  • Set OFF to turn all fixtures OFF at 0%
  • Press Enter to save minute change
  • Press Enter to save changes
  • Repeat and set hour/minute for OFF time

automatically · Output Power

Page 6 of the NextLight PRO Series CONTROL user manual — OUTPUT SELECT AUTO SCREENSAVER OFF
Page 6 · click to enlarge
Page 6

8. Settings (cont.)

F. Rise/Fall

H. Temp Calibrate

I. Factory Reset

OUTPUT SELECT AUTO SET RAMP TIME 30 MIN

OUTPUT SELECT AUTO TEMP CALIBRATE 80.0°F

OUTPUT SELECT AUTO FACTORY RESET NO

Set time period for sunrise and sunset

Set Temperature Sensor calibration

Set controller to original factory settings

  • Press Up/Down to change minute value

Temperature Sensor may become less sensitive

  • Press Up/Down to change YES/NO
  • Set 1 - 60 minutes or NONE

or get oxidized causing temperature on

  • Select YES and press Enter to save and return
  • Press Enter to save changes

controller to be different from actual ambient

to original factory settings

temperature.

  • Press Up/Down to change Temp Calibrate value
  • Press Enter to save changes

G. System Date/Time

For example:

J. Screen Saver

  • Temperature shown on controller is 79.0ºF

OUTPUT SELECT AUTO SET DATE OR TIME DATE: 2021-01-01 TIME: 07:00:00

OUTPUT SELECT AUTO SCREENSAVER OFF

  • Real ambient temperature is 80.0ºF tested by a reliable

third party temperature sensor

  • There is a 1ºF difference

Set local date and time

  • Set Temp Calibrate setting to match ambient
  • Press Up/Down to change date values
  • Press Up/Down to change ON/OFF
  • Press Enter to save changes
  • This will offset all readings from Temperature Sensor
  • Select ON to turn screen off after one minute
  • Press Up/Down to change time values
  • Select OFF and screen will stay on
  • Press Enter to save changes
  • Press Enter to save changes

Set Screensaver ON/OFF · temperature (80ºF) · by 1ºF

Page 7 of the NextLight PRO Series CONTROL user manual — Legal Disclaimer
Page 7 · click to enlarge
Page 7

9. Safety Recommendations and Warnings

11. Five (5) Year Full Manufacturer’s Warranty

NextLight PRO Series CONTROL — 9. Safety Recommendations and Warnings diagram (page 7)
Fig. 8 · 9. Safety Recommendations and Warnings

All NextLight products carry a Five (5) Year Full

Manufacturer’s Warranty from date of purchase. Please

  • Please check and adhere to all local rules, regulations and zoning codes when installing.

follow all instructions and guidelines to ensure warranty

  • The installer is responsible for correct and safe installation of light system.

is not voided. This warranty does not apply to any

  • The NextLight Control Pro may only be used to control NextLight Pro Series products.

product which has been damaged, defaced, subjected to

Do NOT connect the controller to other products as this may be dangerous and may cause

misuse, abnormal service or handling (including shipping

malfunctions in the connected equipment. Doing so will void the warranty.

damage) or which has been altered in design or construction.

  • Do NOT hang Controller by Power Cord.
  • Only use Power Cords that were supplied with your Controller.
  • Do NOT use the Controller with a damaged Power Cord.
  • Do NOT attempt to open, rewire or reconfigure any components of the Controller. It will

void the warranty and could cause serious injury or death.

To file a Warranty Claim, visit nextlight.com/warranty

  • Always disconnect power from the Controller before moving or cleaning it.
  • Do NOT clean the Controller with detergents, abrasives or other aggressive substances.
  • Do NOT use the Controller near flammable, explosive or reactive substances.
  • Keep the Controller away from excessive heat, water, dust and contamination.
  • Do NOT use any Volatile Organic Compounds (VOCs) on or near the Controller. VOCs can

cause damage to the components (including insect foggers).

  • If the surface of the NextLight Control Pro is dirty, wipe it with a dry towel.

This product is for horticulture use only. Not suitable for room illumination.

10. NextLight Support

Legal Disclaimer

NextLight products are to be used for lawful purposes only. It is the responsibility of you as the purchaser to know and abide by all laws pertaining to the use of NextLight products. NextLight, LLC will NOT be held liable for any unlawful state or federal activity arising out of the use of our products. By purchasing a NextLight product, you are agreeing to these terms and conditions, confirming that you as the purchaser are attesting to the lawful use of our product and are thereby solely responsible for acting in conformance with all applicable regulations.

Please scan the QR code to access our online Support page,

which includes the User Manual, FAQ and additional Warranty

Claim information.

nextlight.com/support

Page 8 of the NextLight PRO Series CONTROL user manual — 513.718.7556 513.718.7556
Page 8 · click to enlarge
Page 8
NextLight PRO Series CONTROL — Thank you for choosing Thank you for choosing diagram (page 8)
Fig. 9 · Thank you for choosing Thank you for choosing
NextLight PRO Series CONTROL — Thank you for choosing Thank you for choosing diagram (page 8)
Fig. 10 · Thank you for choosing Thank you for choosing
NextLight PRO Series CONTROL — Thank you for choosing Thank you for choosing diagram (page 8)
Fig. 11 · Thank you for choosing Thank you for choosing

Thank you for choosing Thank you for choosing

Questions about your NextLight Pro Series products? Questions about your NextLight Pro Series products?

513.718.7556 513.718.7556

[email protected] [email protected]

©2021 NextLight. All Rights Reserved. ©2021 NextLight. All Rights Reserved.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the NextLight PRO Series CONTROL

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the NextLight PRO Series CONTROL

Be the first to ask — other owners or our team will answer.

Original document

NextLight PRO Series CONTROL manual PDF

8 pages·756 KB·Controller·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…