EN
McIntosh logo
Official user manual

McIntosh Power Controller (MPC500)

20 pages·2.4 MB·Controller·PDF·ENDEFRITNLJA
McIntosh Power Controller (MPC500)
Table of Contents 23 sections MPC500 · Power Controller · Owner’s Manual · Connector and Cable Information · … ShowHide
Page 1 of the McIntosh Power Controller (MPC500) user manual — MPC500
Page 1 · click to enlarge
Page 1

McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 www.mcintoshlabs.com

McIntosh Power Controller (MPC500) — MPC500 diagram (page 1)
Fig. 1
McIntosh Power Controller (MPC500) — MPC500 diagram (page 1)
Fig. 2

MPC500

Power Controller

Owner’s Manual

McIntosh Power Controller (MPC500) — MPC500 diagram (page 1)
Fig. 3
McIntosh Power Controller (MPC500) — MPC500 diagram (page 1)
Fig. 4
Page 2 of the McIntosh Power Controller (MPC500) user manual — MPC500
Page 2 · click to enlarge
Page 2
Page 2 of the McIntosh Power Controller (MPC500) user manual — MPC500
Page 3 of the McIntosh Power Controller (MPC500) user manual — PIN 6
Page 3 · click to enlarge
Page 3

Connector and Cable Information

MPC500 Versions 120VAC230VAC Watts Rating on componentApproximate currentApproximate current 050 Watts0.5A0.25A 51-100 Watts1A0.5A 101-150 Watts1.5A0.75A 151-200 Watts2A1A 201-250 Watts2.5A1.25A

following information includes the eight pin connector Socket and the Ethernet Connection Cable.

Ethernet RJ45 Socket 1. Transmit Data (+) 5. N/C 2. Transmit Data (-) 6. Receive Data (-) 3. Receive Data (+) 7. N/C 4. N/C 8. N/C

Ethernet Cable - Straight Thru Connections

7. For additional information on the MPC500 and other McIntosh Products please visit the McIntosh Website at www.mcintoshlabs.com

Pin 8 Pin 1

Connector and Cable Information

Pin Number - Wire Color Pin Number - Wire Color 1. Orange/White → 1. Orange/White 2. Orange → 2. Orange 3. Green/White → 3. Green/White 4. Blue → 4. Blue 5. Blue/White → 5. Blue/White 6. Green → 6. Green 7. Brown/White → 7. Brown/White 8. Brown → 8. Brown

RS232 Data Port Cable The RS232 Data Cable has 3.5mm stereo mini phone plug at both ends of the cable. Some Source Component Products use a sub miniature DB9 Connector on their rear panels. Therefore, connecting from those Source Components requires an adaptor cable with a 3.5mm Stereo Mini Phone Plug on one end to a DB9 Connector on the other end of the cable. Those type of cables are available from various retail stores that sell Computer Cables.

PIN 1

PIN 5

Antenna “F” Connector ANTenna IN, connects to the Cable Company Signal. The ANTenna OUT, connects to a FM Tuner Connec- tor.

PIN 6

PIN 9 DB9 (male connector)

Ethernet Network Cable The Ethernet Data Cable is for the connection of Data Signal from an Outside Data Network Source to vari- ous Audio/Video System Components. The Ethernet RJ45 Socket has eight electrical connections of which includes Receiving Data and Transmitting Data. The

Ground Coaxial Shielded Cable

Show 7 more labels / short text on this page
Pin 1 · Pin 8 · Data In (DB9-pin2) · Data Out (DB9-pin3) · Ground (DB9-pin5) · “F” Connector · Data Signal
Page 4 of the McIntosh Power Controller (MPC500) user manual — Performance Features
Page 4 · click to enlarge
Page 4

Introduction

The McIntosh MPC500 Power Controller provides a High Degree of Continuous Surge Protection to the Audio/Video Components that are connected to the MPC500 while performing their operational func- tions.

nected components by continuously monitoring the input voltage and then switching off the rear outlets during a fault.

  • Power Control Assignment The Power Control input connection provides convenient switching ON/OFF of any connected components by removing/connecting the power from the desired outlet. All the Power Control ports are individually configured allowing for extreme customization.

Performance Features

  • Illuminated Multifunction Display The comprehensive On-Screen Display makes it easy to perform setup. The Front Panel display indicates Voltage and Current at all times of connected McIntosh Components along with other operating functions.
  • Power Control The Power Control Input connection provides convenient Turn-On/Off of the McIntosh MPC500 with your McIntosh System.
  • AC Line Surge Protection & EMI Filtering The McIntosh MPC500 utilizes the finest, most sophisticated surge suppression technology available. It incorporates TPMOVs that are thermally protected from abnormal overvoltage occurrences and have four times the surge capability of the common MOVs (Metal Oxide Varistor) devices used by other companies. The MPC500 also offers EMI Filtering from the AC Line source for the components connected to it.
  • Glass Front Panel and Super Mirror Chassis Finish The famous McIntosh Illuminated Glass Front Panel uses long life Light Emitting Diodes (LEDs) and the Steel Chassis ensures the pristine beauty of the MPC500 will be retained for many years.
  • Low Voltage DC Surge Protection The McIntosh MPC500 utilizes GDT (Gas Discharge Tubes), PTC (Positive Temperature Coefficient thermistors) and TVS (Transient Voltage Suppression) components to protect your low voltage devices. This cascade approach provides a lower clamping voltage with increased surge capability.
  • Over/Under Voltage Protection The McIntosh MPC500 Over/Under Voltage Protection circuitry prevents possible damage to your con-
Page 5 of the McIntosh Power Controller (MPC500) user manual — Dimensions
Page 5 · click to enlarge
Page 5

Dimensions

Dimensions The following dimensions can assist in determining the best location for your MPC500.

Front View of the MPC500

McIntosh Power Controller (MPC500) — Dimensions diagram (page 5)
Fig. 5 · Dimensions

Side View of the MPC500

McIntosh Power Controller (MPC500) — Dimensions diagram (page 5)
Fig. 6 · Dimensions
McIntosh Power Controller (MPC500) — Dimensions diagram (page 5)
Fig. 7 · Dimensions

2" 5.1cm 1-15/16" 4.9cm Rear View of the MPC500 (220V-240V)

Page 6 of the McIntosh Power Controller (MPC500) user manual — Installation
Page 6 · click to enlarge
Page 6

Installation

Installation The MPC500 can be placed upright on a table or shelf, standing on its four feet. It also can be custom installed in a piece of furniture or cabinet of your choice. The four feet may be removed from the bottom of the MPC500 when it is custom installed as out- lined below. The four feet together with the mounting screws should be retained for possible future use if the MPC500 is removed from the custom installation and used free standing. The required panel cutout, ventila- tion cutout and unit dimensions are shown. Always provide adequate ventilation for your MPC500. Cool operation ensures the longest possible operating life for any electronic instrument. Do not install the MPC500 directly above a heat generat- ing component such as a high powered amplifier. If all the components are installed in a single cabinet, a quiet running ventilation fan can be a definite asset in maintaining all the system components at the coolest possible operating temperature. A custom cabinet installation should provide the fol- lowing minimum spacing dimensions for cool opera- tion. Allow at least 2 inches (5.08cm) above the top, 2 inches (5.08cm) below the bottom, 3 inches (7.62cm) behind the rear panel and 2 inches (5.08cm) on each side of the Power Controller, so that airflow is not obstructed. Allow 7/8 inch (2.22cm) in front of the mounting1 panel for clearance. Be sure to cut out a ventilation hole in the mounting shelf according to the dimensions in the drawing.

McIntosh Power Controller (MPC500) — Installation diagram (page 6)
Fig. 8 · Installation

MPC500 Front Panel Custom Cabinet Cutout

MPC500 Side View in Custom Cabinet

MPC500 Bottom View in Custom Cabinet

1 When the MPC500 is installed together with other Mc- Intosh Components, check clearances on all components before proceeding.

Page 7 of the McIntosh Power Controller (MPC500) user manual — Installation
Page 7 · click to enlarge
Page 7
Page 7 of the McIntosh Power Controller (MPC500) user manual — Installation
Page 8 of the McIntosh Power Controller (MPC500) user manual — Rear Panel Connections MPC500 (100V-120V)
Page 8 · click to enlarge
Page 8

Rear Panel Connections MPC500 (100V-120V)

POWER CONTROL OUTputs send turn On/Off Signals to a connected McIntosh Component. POWER CONTROL INputs receive turn On/Off signals from a McIntosh Component

UNSWITCHED AC OUTLETS (1) become active when the MPC500 AC POWER CORD is connected to an active external AC Outlet

SWITCHED AC OUTLETS (2-4) are con- trolled by MPC500 POWER CONTROL Settings and/or the received Power Control Signal from other components

CIRCUIT BREAKER PRESS TO RESET if the MPC500 Power Controller will not power up

NETwork/IN provides protection for input Data Signal from Outside Data Network Source. NETwork/OUT provides the protected Data Signal from the Network Input for connection to Audio/Video Components

RS232/IN provides protection for the Serial Data Input Signal from a RS232 Output from another connected Audio/Video Component. RS232/OUT provides a protected Serial Data Output Signal to be connected to other Audio/Video Components

Connect the MPC500 power cord to a live AC outlet. Refer to infor- mation on the back panel of your MPC500 to determine the correct voltage for your unit

ANTenna/IN provides protection for the FM RF Signal from Outside FM Network Source. ANTenna/OUT provides the protected FM RF Signal for connection to Audio/Video Tuner Components

Page 9 of the McIntosh Power Controller (MPC500) user manual — How to Connect MPC500 for (100V-120V)
Page 9 · click to enlarge
Page 9

How to Connect MPC500 for (100V-120V)

How to Connect MPC500 for (100V-120V)

OUT Connector to the Network Router/Switch and Ethernet Crossover Adapter Input Connector. 6. Connect Network Cables from the Router/Switch or Ethernet Crossover Adapter NETWORK Output connectors to each of the Audio/Video Compo- nents (A/V Control Center, Media Bridge, and any addition components) with NETWORK Connec- tors. RS232 Connections: Use either type of RS232 Cables to make the neces-

11. Connect an AC Power Cord from the A/V Control Center to the MPC500 UNSWITCHED Upper Outlet Number 1. 12. Connect an AC Power Cord from the Media Bridge External Power Supply to the MPC500 Switched Upper Outlet Number 2. 13. Connect an AC Power Cord from the AM/FM Tuner to the MPC500 Switched Lower Outlet Number 2. 14. Optionally, connect additional Audio/Video Com- ponents AC Power Cords to the MPC500 Switched AC Outlets. Add up the current Amperage ratings of the connected components, making sure that the Total Components do not exceed a total of 12 Amps.

MPC500 Rear Panel until after the Audio/ Video Components have been Connected to the MPC500. The connection instructions below, together with the MPC500 Connection Diagram located on the sepa- rate folded sheet “Mc1A”, are an example of a typical Audio/Video System. The MPC500 has the ability to automatically switch AC Power On/Off to Com- ponents connected to the MPC500 SWITCHED AC OUTLETS (2 thru 4) via the Power Control Con- nection (1 thru 4). Your system may vary from this, however the actual components would be connected in a similar manner. For additional information refer to “Connector and Cable Information” on page 3. Power Control Connections:

sary RS232 Connections. Either a 3.5mm stereo mini phone plug RS232 Cable on both cable ends or when necessary, a cable with Sub Miniature DB9 Connector on one end and a 3.5mm stereo mini phone plug on the other end.

7. Connect the appropriate RS232 Cable from the A/V Control Center RS232 Connector to MPC500 RS232/IN Connector. 8. Connect the appropriate RS232 Cable from the MPC500 RS232/OUT Connector to the AM/FM Tuner RS232 Connector. Antenna Connections: Use a RF Cable with “F” Connectors for providing

1. Connect a Control Cable from the A/V Control Center TRIGger (Power Control) 1 Jack to the POWER CONTROL INput 2 Jack on the MPC500 for primary listening. 2. Connect a Control Cable from the MPC500 POWER CONTROL OUTput 2 Jack to the Media Bridge PWR CTRL (Power Control) IN Jack. 3. Connect a Control Cable from the Media Bridge PWR CTRL (Power Control) OUT Jack to the AM/FM Tuner Power Control IN Jack. Network Connections: Use CAT 5/6 Ethernet Type Cables to provide con-

FM Radio Frequency (or Video) Transmitted Signal between components.

9. Connect a RF Cable from the Cable Company Connection unit to the MPC500 ANT/IN Input Connector. 10. Connect the MPC500 ANT/OUT Connector via a RF Cable with “F” Connectors to the AM/FM Tuner FM ANT Connector. Switched AC Power Outlets: Use the AC Power Cords that were supplied with each

nections between the MPC500 and all the Network Connectors on the Audio/Video Components along with Network Router/Switch and Ethernet Crossover Adapter.

4. Connect a Ethernet Cable from the Cable Company Connection unit Net Output Connector, to the MPC500 NET/IN Connector. 5. Connect a Ethernet Cable from the MPC500 NET/

of the Audio/Video Components in the following steps:

Page 10 of the McIntosh Power Controller (MPC500) user manual — Rear Panel Connections MPC500 (220V-240V)
Page 10 · click to enlarge
Page 10

Rear Panel Connections MPC500 (220V-240V)

UNSWITCHED AC Outlets (1) become ac- tive when the MPC500 AC POWER CORD is connected to an active external AC Outlet

POWER CONTROL OUTputs send turn On/Off Signals to a connected McIntosh Component. POWER CONTROL INputs receive turn On/Off signals from a McIntosh Component

SWITCHED AC OUTLETS (2-4) are con- trolled by MPC500 POWER CONTROL Settings and/or the received Power Control Signal from other components

CIRCUIT BREAKER PRESS TO RESET if the MPC500 Power Controller will not power up

NETwork/IN provides protection for input Data Signal from Outside Data Network Source. NETwork/OUT provides the protected Data Signal from the Network Input for connection to Audio/Video Components

RS232/IN provides protection for the Serial Data Input Signal from a RS232 Output from another connected Audio/Video Component. RS232/OUT provides a protected Serial Data Output Signal to be connected to other Audio/Video Components

Connect the MPC500 power cord to a live AC outlet. Refer to infor- mation on the back panel of your MPC500 to determine the correct voltage for your unit

ANTenna/IN provides protection for the FM RF Signal from a FM Antenna or Outside FM Network Source. ANTenna/OUT provides the protected FM RF Signal for connection to Audio/Video Tuner Components

Page 11 of the McIntosh Power Controller (MPC500) user manual — How to Connect MPC500 for (220V-240V)
Page 11 · click to enlarge
Page 11

How to Connect MPC500 for (220V-240V)

How to Connect MPC500 for (220V-240V)

5. Connect a Ethernet Cable from the MPC500 NET/ OUT Connector to the Network Router/Switch and Ethernet Crossover Adapter Input Connector. 6. Connect Network Cables from the Router/Switch or Ethernet Crossover Adapter NETWORK Output connectors to each of the Audio/Video Components (A/V Control Center, Media Bridge, and any addition components) with NETWORK Connectors. RS232 Connections: Use either type of RS232 Cables to make the neces-

each of the Audio/Video Components in the following steps: 11. Connect an AC Power Cord from the A/V Control Center to the MPC500 UNSWITCHED Upper Outlet Number 1. 12. Connect an AC Power Cord from the Media Bridge External Power Supply to the MPC500 Switched Outlet Number 2. 13. Connect an AC Power Cord from the AM/FM Tuner to the MPC500 Switched Outlet Number 3. 14. Optionally, connect an additional Audio/Video Component AC Power Cords to the MPC500 Switched AC Outlet Number 4. Add up the current Amperage ratings of the connected components, making sure that the Total Components do not exceed a total of 6 Amps.

MPC500 Rear Panel until after the Audio/ Video Components have been Connected to the MPC500. The connection instructions below, together with the MPC500 Connection Diagram located on the sepa- rate folded sheet “Mc1B”, are an example of a typical Audio/Video System. The MPC500 has the ability to automatically switch AC Power On/Off to Com- ponents connected to the MPC500 SWITCHED AC OUTLETS (2 thru 4) via the Power Control Con- nection (1 thru 4). Your system may vary from this, however the actual components would be connected in a similar manner. For additional information refer to “Connector and Cable Information” on page 3. Power Control Connections:

sary RS232 Connections. Either a 3.5mm stereo mini phone plug RS232 Cable on both cable ends or when necessary, a cable with Sub Miniature DB9 Connector on one end and a 3.5mm stereo mini phone plug on the other end.

1. Connect a Control Cable from the A/V Control Center TRIGger (Power Control) 1 Jack to the POWER CONTROL INput 2 Jack on the MPC500 for primary listening. 2. Connect a Control Cable from the MPC500 POWER CONTROL OUTput 2 Jack to the Media Bridge PWR CTRL (Power Control) IN Jack. 3. Connect a Control Cable from the Media Bridge PWR CTRL (Power Control) OUT Jack to the AM/FM Tuner Power Control IN Jack. Network Connections: Use CAT 5/6 Ethernet Type Cables to provide con-

7. Connect the appropriate RS232 Cable from the A/V Control Center RS232 Connector to MPC500 RS232/IN Connector. 8. Connect the appropriate RS232 Cable from the MPC500 RS232/OUT Connector to the AM/FM Tuner RS232 Connector. Antenna Connections: Use a RF Cable with “F” Connectors for providing

FM Radio Frequency (or Video) Transmitted Signal between components.

9. Connect a RF Cable from the Cable Company Connection unit to the MPC500 ANT/IN Input Connector. 10. Connect the MPC500 ANT/OUT Connector via a RF Cable with “F” Connectors to the AM/FM Tuner FM ANT Connector. Switched AC Power Outlets: Use the AC Power Cords that where supplied with

nections between the MPC500 and all the Network Connectors on the Audio/Video Components along with Network Router/Switch and Ethernet Crossover Adapter.

4. Connect a Ethernet Cable from the Cable Company Connection unit Net Output Connector, to the MPC500 NET/IN Connector.
Page 12 of the McIntosh Power Controller (MPC500) user manual — Front Panel Displays and Controls
Page 12 · click to enlarge
Page 12

Front Panel Displays and Controls

DISPLAY CONTROL selects various operation func- tions. Push in the DISPLAY CONTROL to activate the SETUP Operation Modes of various functions selectable by rotating the Control

OUTLET STATE Control switches the MPC500 On or Off by pushing the Control In. Rotate the Control to activate various functions of the AC Outlets

Front Panel Display indicates various operation functions, times and various measurements

LED 1 indicates the condition of the AC 1 Power Outlet

LED 3 indicates the condition of the AC 3 Power Outlet

LED 4 indicates the condition of the AC 4 Power Outlet

LED 2 indicates the condition of the AC 2 Power Outlet

Page 13 of the McIntosh Power Controller (MPC500) user manual — MPC500
Page 13 · click to enlarge
Page 13

How to Operate

How to Operate

Power On and Off After the MPC500 is connected for Audio/Video Components 100V-120V (refer to page 8) or 220V- 240V (refer to page 10), press the OUTLET STATE Control to switch it On. The Front Panel Display will indicate the “MPC500” for several seconds and then followed by “MPC500 --Protected --”. Refer to figures 1 and 2. The MPC500 will then measure the “The AC Line Voltage Level” that it is connected to. The Front Pan- el Display will then indicate the measured Voltage, for the MPC500 (100V-120V) or (220V-240V) unit. Refer to figure 3A or figure 4A. The actual measurements will vary according to the incoming AC Line Voltage for the building where the MPC500 and the rest of the Audio/Video Equipment is physically located.

DISPLAY CONTROL, figures 3A or 4A will now indicate a different display status like figure 3B/4B.

Each of the displays indicate the Status of the MPC500 AC Power Outlets and the Power Con- trol Settings for the AC Power Outlets.

MOV SURGE STATUS Protected

Display Control After the MPC500 is switched On and the Front Panel Display has indicated the previous figures (3A, 4A or 3B/4B), rotate the DISPLAY Control Clockwise to display additional Function Displays. Refer to figures 9 thru 11.

MPC500

Status of the Power AC Outlets After the MPC500 has displayed the incoming line voltage, rotating the OUTLET STATE Control clock- wise will allow for the indication of the MPC500 Operational Status. Rotating the Control will Display the following. Refer to figures 5 thru 8.

AC LINE CURRENT 1.39 Amps

Outlet 1On Power Ctrl: On

AC LINE POWER 180.6 Watts

Outlet 2On Power Ctrl: On

MOV SURGE STATUS Protected

AC LINE VOLTAGE 120.0 Volts

Outlet 3On Power Ctrl: On

By using the DISPLAY Control to select Figure 3A/4A, 3B/4B, 9, 10 or 11, it will now determine, when the MPC500 is switched on, which figure will be dis- played after Figure 1 and Figure 2 is displayed.

Figure 4a AC LINE VOLTAGE 220.0 Volts

Outlet 4On Power Ctrl: On

and the selection of the various Setup Operat- ing Function was previously changed using the

Figure 3B/4B · MPC500 Protected

Page 14 of the McIntosh Power Controller (MPC500) user manual — MPC500 V1.00 S/N: _______
Page 14 · click to enlarge
Page 14

How to Operate, con’t

Setup Operating Mode After the MPC500 is On and the Front Panel is Dis- playing Figures 3A/4A, 3B/4B, 9, 10 or 11, it is now time to operate the MPC500 SETUP Mode. Press DISPLAY CONTROL and the following is displayed. Referring to figure 12 of which is displaying the Ver- sion Number and Serial Number of this MPC500.

Control Output Setting as the Power Control 1 Output of which is On. The LOCAL Setting for the selected Power Control Output provides the same function as its Power Control Input Connection. Follow the steps below to change the current setting for one or more of the MPC500 Power Control Output Connectors:

4. Rotate the OUTLET STATE Control to select the setting of GLOBAL or LOCAL. Refer to figures 19 and 20.
SETUPOutlet 2 Power Ctrl: Global
1. After the MPC500 has been switched on for several seconds, rotate the OUTLET STATE Control Clockwise to display the following for Power Control 2. Refer to figure 16.

MPC500 V1.00 S/N:

SETUPOutlet 2 Power Ctrl: Local
Outlet 2On Power Ctrl: On

Figures 13 thru 15 are MPC500 Settings where adjust- ments can be made for each of the operating functions.

5. Once the new Power Control Setting has been selected, press the DISPLAY CONTROL.
SETUPOutlet Config (Hold SETUP)
2. Press DISPLAY CONTROL and then rotate the control until it displays “SETUP: Outlet Config (Hold SETUP)”. Refer to figure 17.

Setup Display Brightness Configuration The Front Panel Display Brightness is adjustable via a

Setup Mode of operation.

1. Press DISPLAY CONTROL and then rotate the control until it displays “DISPLAY Brightness”. Refer to figure 21.
SETUPOutlet Config (Hold SETUP)

FACTORY RESET (Hold SETUP)

3. Press DISPLAY CONTROL and the Front Panel Display will indicate the following setting for Power Control 2. Refer to figure 18.
2. Then rotate the OUTPUT STATE Control clockwise to increase the current Brightness Level or rotate Control Counter Clockwise to reduce the current Brightness Level. 3. After the Brightness Level has been adjusted to the desired level, then press the DISPLAY CONTROL to end the adjustment of the Brightness Level.

Setup Outlet Configuration The Power Control Output Connections of 2, 3 & 4 on the MPC500 can be changed from the normal default settings of ON to a setting of ON, GLOBAL or LO- CAL. The GLOBAL Setting provides the same Power

SETUPOutlet 2 Power Ctrl: On

DISPLAY Brightness · DISPLAY Brightness

Page 15 of the McIntosh Power Controller (MPC500) user manual — How to Operate, con’t
Page 15 · click to enlarge
Page 15

How to Operate, con’t

Setup Factory Reset Operation If the MPC500 Operational Settings need to be re-

stored to the default settings perform the following:

1. Press DISPLAY CONTROL and then rotate the Control until the Front Panel displays “FACTORY RESET (Hold SETUP). Refer to figure 22.

FACTORY RESET (Hold SETUP)

2. Then press in and hold the DISPLAY CONTROL as the Front Display changes from figure 22 to figure 23 followed by figure 24. Then release the Display Control.

FACTORY RESET In Progress

3. The AC Power to the MPC500 will now be switched Off. 4. Press the OUTPUT STATE Control to switch the MPC500 AC Power back On.

FACTORY RESET Completed!

Page 16 of the McIntosh Power Controller (MPC500) user manual — How to Operate, con’t
Page 16 · click to enlarge
Page 16
McIntosh Power Controller (MPC500) — How to Operate, con’t diagram (page 16)
Fig. 9 · How to Operate, con’t
Page 17 of the McIntosh Power Controller (MPC500) user manual — Photos
Page 17 · click to enlarge
Page 17

Photos

McIntosh Power Controller (MPC500) — Photos diagram (page 17)
Fig. 10 · Photos
Page 18 of the McIntosh Power Controller (MPC500) user manual — General Specifications
Page 18 · click to enlarge
Page 18

MPC500 - Specifications (100V-120V and 220V-240V

MPC500 Protection and Technologies AC Mains Protection Surge: 20kA (8x20kA) PER MODE Modes of Protection: L-N, L-G, N-G

Voltage and Power Specifications MPC500 (100V-120V) Input Voltages 100 - 120 Volts AC Nominal

General Specifications

Overall Dimensions Width is 17-1/2 inches (44.5cm) Height is 6 inches (15.2cm) including feet Depth is 19 inches (48.26cm) including the Front Panel, Knobs and Cables

RS232 Connections Thermally Protected and Low Voltage DC Protection: Surge: 5kA (8x20us) Maximum Operating Voltage: 15VDC Maximum Operating Current: 350mA DC Clamping Voltage: 24Volts Technology: GDT, PTC and TVS

Output Voltages 100 - 120 Volts AC Nominal

Weight 18.5 pounds (8.39 kg) net, 34 pounds (15.42 kg) in shipping carton

Power Requirement 100V - 120V ~ 50/60Hz 12 Amps, maximum current 1440 Watts, maximum wattage

Shipping Carton Dimensions Width is 26-1/2 inches (67.3cm) Depth is 24-1/4 inches (61.6cm) Height is 11-3/4 inches (29.9cm)

MPC500 (220V-240V) Input Voltages 220 - 240 Volts AC Nominal

ETHERNET Connections Thermally Protected and Low Voltage DC Protection: Surge: 10kA (8x20us) Maximum Operating Voltage: 58VDC Technology: TVS

Output Voltages 220 - 240 Volts AC Nominal

Power Requirement 220V - 240V ~ 50/60Hz 6 Amps, maximum current 1440 Watts, maximum wattage

COAXIAL Connections Thermally Protected and Low Voltage DC Protection: Surge: 5kA(8x20us) DC Clamping Voltage: 75VDC Technology: GDT

Page 19 of the McIntosh Power Controller (MPC500) user manual — Packing Instructions
Page 19 · click to enlarge
Page 19

Packing Instructions

Packing Instructions

In the event it is necessary to repack the equipment for shipment, the equipment must be packed exactly as shown below. It is very important that the four plas- tic feet are attached to the bottom of the equipment. This will ensure the proper equipment location on the bottom pad. Failure to do this will result in shipping damage. Use the original shipping carton and interior parts only if they are all in good serviceable condition. If a shipping carton or any of the interior part(s) are needed, please call or write Customer Service Depart- ment of McIntosh Laboratory. Refer to page 2. Please see the Part List for the correct part numbers.

Quantity Part Number Description 1 033838 Shipping carton only 2 033837 End caps

1 033836 Inside carton only 1 033725 Top pad 1 034576 Bottom pad

4 017937 Plastic foot 4 400159 #10-32 x 3/4” screw 4 404080 #10 Flat washer

McIntosh Power Controller (MPC500) — Packing Instructions diagram (page 19)
Fig. 11 · Packing Instructions
Page 20 of the McIntosh Power Controller (MPC500) user manual — Packing Instructions
Page 20 · click to enlarge
Page 20

McIntosh Laboratory, Inc.

2 Chambers Street Binghamton, NY 13903 www.mcintoshlabs.com

The continuous improvement of its products is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice. Printed in the U.S.A.

McIntosh Part No. 04193301

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the McIntosh Power Controller (MPC500)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the McIntosh Power Controller (MPC500)

Be the first to ask — other owners or our team will answer.

Original document

McIntosh Power Controller (MPC500) manual PDF

20 pages·2.4 MB·Controller·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…